Product Information PI TOSHIBA X-RAY TUBE D-054 / D-054S / D-054SB Stationary Anode X-ray Tube Especially designed for dental radiography unit. Low target angle adaptive for dental tomography. Provided with an insulation cylinder (D-054S) and lead cylinder. (D-054SB) These tubes have 0.5 focus, and are available for maximum tube voltage 100 kV. Installed in the same enclosure with the high voltage transformer. General Data Electrical: Circuit: High Voltage Generator ......................................................... Two-Peak High-Voltage Generator Constant Potential High-Voltage Generator Grounding ......................................................................................................... Center-Grounded Nominal X-ray Tube Voltage ................................................................................................... 100 kV Nominal Focal Spot Value ............................................................................................................ 0.5 Nominal Anode Input Power (at 1.0s) (See Rating Chart) Two-Peak High-Voltage Generator ..................................................................................... 840 W Constant Potential High-Voltage Generator ...................................................................... 1750 W Exposure Duty Cycle ..................................................................................................... 1:60 or more (Exposure time : interval time) Mechanical: Dimensions: Overall Length ......................................................................................... See dimensional outline Maximum Diameter ................................................................................. See dimensional outline Target: Anode Angle ................................................................................................................. 5 degrees Material .......................................................................................................................... Tungsten Inherent Filtration .................................................................................... At least 0.8 mm Al at 50 kV X-ray Coverage .................................................................................... 75 × 380 mm at SID 550 mm ★The information contained herein is presented only as a guide for the applications of our products. No Responsibility is assumed by TOSHIBA ELECTRON TUBES & DEVICES CO.,LTD.(TETD) for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TETD or others. ★The information contained herein may be changed without prior notice. It is therefore advisable to contact TETD before proceeding with the design of equipment incorporating this product. D-054 / D-054S / D-054SB Weight: D-054 ...................................................................................................................... Approx. 320 g D-054S .................................................................................................................... Approx. 460 g D-054SB ................................................................................................................. Approx. 780 g Cooling Method .............................................. Oil immersed (60℃ Max.) and convection oil cooling. Tube Holding: D-054 ......................................... Holding the glass envelope of the anode end and cathode end, or the screw of the anode shank. D-054S .......................................................................................... Holding the insulation cylinder. D-054SB ............................................................................................... Holding the lead cylinder. Absolute Maximum and Minimum Ratings (At any time, these values must not be exceeded.) Maximum X-ray Tube Voltage .................................................................................................. 100 kV Between Anode (or Cathode) and Ground ................................................................................. 50 kV Minimum X-ray Tube Voltage ..................................................................................................... 50 kV Maximum X-ray Tube Current: ................................................................................. See rating charts Two-Peak High-Voltage Generator ..................................................................................... 24 mA Constant Potential High-Voltage Generator ........................................................................ 22 mA Maximum Filament Current ........................................................................................................ 3.5 A Maximum Filament Voltage ........................................................................................................ 4.2 V Filament Frequency Limits ........................................................... DC or AC (Sine Wave) 0 ~ 20 kHz Thermal Characteristics: Anode Heat Content ............................................................................................................ 35 kJ Maximum Anode Heat Dissipation ...................................................................................... 250 W Maximum Radiographic Exposure Time ...................................................................................... 20 s Environmental Limits Operating Limits (in dielectric oil): Oil Temperature ........................................................................................................... 10 ~ 60 ℃ Oil Pressure ............................................................................................................. 70 ~ 140 kPa Shipping and Storage Limits: Temperature .............................................................................................................. -40 ~ 70 ℃ Humidity ........................................................................................................................ 10 ~ 90 % (No condensation) Atmospheric Pressure .................................................................................................50 ~ 106 kPa -2- D-054 / D-054S / D-054SB Maximum Rating Charts (Absolute maximum rating charts) Two-Peak High-Voltage Generator Nominal Focal Spot Value: 0.5 50kV 24 60kV TUBE CURRENT [mA] 20 70kV 80kV 15 90kV 100kV 10 5 1 2 3 5 7 10 20 EXPOSURE TIME [s] Constant Potential High-Voltage Generator Nominal Focal Spot Value: 0.5 70kV 80kV 22 60kV 90kV 20 50kV TUBE CURRENT [mA] 100kV 15 10 5 1 2 3 5 7 EXPOSURE TIME [s] -3- 10 20 D-054 / D-054S / D-054SB Emission & Filament Characteristics Two-Peak High-Voltage Generator Nominal Focal Spot Value: 0.5 7 TUBE CURRENT [mA] 20 6 50kV 15 5 100kV 10 4 Ef 5 3 0 2.9 3.0 3.1 3.2 3.3 3.4 FILAMENT VOLTAGE [V] 25 2 3.5 FILAMENT CURRENT [A] Note: This graph indicates typical characteristics. Constant Potential High-Voltage Generator Nominal Focal Spot Value: 0.5 6 25 5 TUBE CURRENT [mA] 20 100kV Ef 15 4 3 10 50kV 2 5 0 2.9 3.0 3.1 3.2 3.3 3.4 1 3.5 FILAMENT CURRENT [A] Note: This graph indicates typical characteristics. -4- FILAMENT VOLTAGE [V] 80kV D-054 / D-054S / D-054SB Anode Heating / Cooling Curve 35 225W HEAT STORAGE [kJ] 30 175W 25 HEATING 20 15 10 COOLING 5 0 0 2 4 6 TIME [min] -5- 8 10 D-054 / D-054S / D-054SB Dimensional Outline of D-054 Unit: mm φ15.7 73±1 (8) M6 8DEEP 138±3 5° CENTRAL X-RAY φ45MAX 14MAX FOCAL SPOT C2 F N 3 0. 2 φ CENTRAL X-RAY C1 F SHORT PIN F :FILAMENT C1,C2:CATHODE N :NOT FOR USE -6- D-054 / D-054S / D-054SB Dimensional Outline of D-054S Unit: mm φ54 INSULATION CYLINDER M6 8DEEP φ25 73±1 φ15.7 143 146±3 5° CENTRAL X-RAY 6MAX FOCAL SPOT 3 0. φ2 C2 F CENTRAL X-RAY N C1 F SHORT PIN F :FILAMENT C1,C2:CATHODE N :NOT FOR USE -7- D-054 / D-054S / D-054SB Dimensional Outline of D-054SB Unit: mm φ58 φ54 INSULATION CYLINDER M6 8DEEP φ30 65 143 146±3 5° 40 φ25 73±1 30 φ15.7 CENTRAL X-RAY FOCAL SPOT 6MAX LEAD SYLINDER 3 0. φ2 F C2 CENTRAL X-RAY N F C1 SHORT PIN F :FILAMENT C1,C2:CATHODE N :NOT FOR USE -8- D-054 / D-054S / D-054SB OVERSEAS SUBSIDIARIES AND AFFILIATES EU REPRESENTATIVE ・TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE 181 40549 DÜSSELDORF, GERMANY PHONE +49 (211) 5296-107 FAX +49 (211) 5296-402 For Sales & Technical Services, please contact the following representative: ・TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE 181 40549 DÜSSELDORF, GERMANY PHONE +49 (211) 5296-107 FAX +49 (211) 5296-402 ・TOSHIBA AMERICA ELECTRONIC COMPONENTS, INC. 2150 EAST LAKE COOK ROAD, SUITE 310 BUFFALO GROVE, ILLINOIS 60089 USA PHONE +1 (847) 484-2400 FAX +1 (847) 541-7287 ・TOSHIBA ELECTRON DEVICES & MATERIALS (SHANGHAI) CO., LTD. (TEMS) RM1606, SH-PLAZA, No.336, XIZANG ROAD (MIDDLE), SHANGHAI, 200001, CHINA PHONE +86 (21) 6361-0077 FAX +86 (21) 6351-5760 (Product Development Engineering Department) 1385 SHIMOISHIGAMI, OTAWARA-SHI, TOCHIGI-KEN, 324-8550, JAPAN PHONE: +81-287-26-6666 FAX: +81-287-26-6060 http://www.toshiba-tetd.co.jp/ ・Toshiba Electron Tubes & Devices Co., Ltd. meets the Environmental Management System Standard, ISO14001. ・Toshiba Electron Tubes & Devices Co., Ltd. meets internationally recognized Standards for Quality Management System ISO9001, ISO13485.