ELECTRONICS www.techrentals.com.au Multimeters & Electrometers Digital Storage Oscilloscopes Probes & Accessories Function Generators LCR Meters DC Power Supplies & Loads Spectrum Analysers - Low Frequency TV Test Equipment Laboratory Calibrators Logic Analysers/PROM Programmers Gauss/Tesla Meters E & H Field Strength Meters EMC & Power Disturbance Simulators Multimeters & Electrometers cont’d. LEM Unigor 355 Hand-held Digital Multimeter/Signal Generator LEM,UNIGOR355 (1214) AU Measures DC, AC true RMS voltage & current, resistance, frequency, capacitance, temperature & time. Display 4¾ digit. Resolution 10μV, 10nA, 10mΩ, 1pF & 0.01Hz. Ranges voltage 300mV to 1kV, current 300μA to 10A, resistance 300Ω to 30MΩ, frequency 300Hz to 100kHz, -48 to 63dB, temperature ºC/ºF, Pt 100 -200 to 100ºC, Pt 1000 100 to 850ºC. Features automatic socket shutters, IR interface, split second chronograph, automatic measurement value storage, etc. Metrix MX51EX Intrinsically Safe Digital Multimeter MET,MX51EX (1204) AU Resolution 5,000 count with 0.1% basic accuracy. Measures AC/DC voltage & current, & resistance. Voltage sensitivity 100μV. Max voltage 1kVDC, 750VAC. Max current 10A. Intrinsic safety limits of 60V & 500mA. Vermason 222541 Electrostatic Meter VER,222ES (1246) AU Electrostatic meter for periodic audits of facilities, monitoring packaging, materials, machines and other electrostatic generative equipment or processes. This precision field meter is designed to measure electrostatic voltage potentials over selected distances from 1 to 20cm. Range at the standard distance of 2cm is 20kV. Two range 3 digit display in V or kV. Multimeters & ElectrometersTe See also Electrical Testers on page 29-30 Fluke 87-5 Industrial True-RMS Multimeter with Thermometer FLU,87-5 MY Unique function for accurate voltage and frequency measurements on adjustable speed. True-RMS AC voltage and current for accurate measurements on non linear signals. Built in thermometer. Measure up to 1,000VAC and DC. Measure up to 10A (20A for 30 seconds). 10,000uF capacitance range. Frequency to 200kHz and % duty cycle. Peak capture to record transients as fast as 250μs. 4½ digit mode. Digital Storage Oscilloscopes Agilent MSOX3024A 200MHz Scope 4+16Ch with Logic Analyser AGI,MSOX3024A (1340) Fluke Multimeter with Backlight FLU,177 (1209) AU General purpose multimeter 0.09% basic accuracy. True RMS voltage & current measurements, digital display with analog bargraph & backlight, manual & automatic ranging, display Hold & Auto Hold, frequency & capacitance measurements. Overvoltage category EN61010-1 CAT III 1000V/ CAT IV 600V. Agilent MSO6104A 1GHz Digital Oscilloscope with Logic AGI,MSO6104A (1345) AU True-RMS multimeter. Large 50,000-count 1/4 VGA dot matrix display. 0.025% Basic DC accuracy. CAT III 1000 V/CAT IV 600V safety rated. Fluke 199C Scopemeter 200MHz Hand-held FLU,199C-SCOPEMETER (1361) AU 200MHz bandwidth 2 channel colour digital oscilloscope with DMM feature. 14.4cm colour display with persistence feature. 2.5GS/s real time sampling. Input sensitivity 5mV/div to 100V/div. Glitch capture 3ns using pulse width triggering. Timebase range in scope mode 5ns/div to 2min/div. Trigger types auto, free run, single shot, edge, delay, video, video line, selectable pulse width and external. Automatic capture and replay of last 100 screens. Measures electrical power properties such as VA VAR, etc. Isolated inputs. Agilent/HP 34401A Digital Multimeter HP,34401A (1200) AU 1GHz 4 + 16 channel mixed signal oscilloscope (MSO). 4Gsa/s. XGA Colour display updates 100,000 waveforms/s with 256 levels intensity. 4 analogue channels & 16 logic channels. Deep memory. 8 digit frequency counter function. Triggering includes video, HDTV, I2C, SPI, LIN, CAN, & USB. FFT analysis included. LAN, USB, GPIB, & XGA interfaces standard. Fluke 289 True-RMS Industrial Logging Multimeter with TrendCapture FLU,289 (1208) AU Mixed signal oscilloscope. 4 analogue and 16 digital channels 200 MHz bandwidth, 4 GS/s, 2 Mpts memory, 1 M/s waveform update rate. Search and navigate capability. Integrated time-aligned digital and analog signal viewing. USB storage, LAN operability. AU Precision 6½ digit multimeter. 100nV sensitivity on DC 120mV range. Max DC input 1kV. Measures AC voltage, DC & AC current to 3A, 2 or 4 wire resistance to 120MΩ, period & frequency. Max reading rate 1,000/s. Maths functions including limits test. 512 point storage. RS232 & HPIB interfaces. 8 ELECTRONICS www.techrentals.com.au Digital Storage Oscilloscopes cont’d. Digital Storage Oscilloscopes cont’d. Tektronix TDS2024B 200MHz Digital Oscilloscope TEK,TDS2024B (1332) Tektronix TPS2014 100MHz 4 Channel Powerscope AU TEK,TPS2014 (1321) 4 channel 200MHz bandwidth colour digital storage oscilloscope. 2GS/s sampling rate. Sensitivity 2mV to 5V/div. Automatic waveform measurements. Includes FFT analysis as standard. Removable data storage via front panel USB port. AU Sampling rate 1GS/s. All 4 channels isolated for floating measurements. Sensitivity 2mV to 5V/div. Measurements for current and voltage distortion and their spectral content, harmonics, instantaneous power, power factor and switching loss. Automatic waveform measurements. FFT, power analysis, low & high voltage power probes (P5120). Battery operation. Tektronix TDS3052B 2 Channel 500MHz DSO TEK,TDS3052B (1342) AU Probes and Accessories Sampling rate 5GS/s. Memory length 10k. Sensitivity 1mV to 10V/div. Time base 1ns to 10s/div. Trigger functions include video. Automatic waveform measurements. FFT Analysis. Wave alert & e-scope web based control. Colour LCD with digital phosphor function. Centronics, GPIB (IEEE-488), Ethernet, & RS232 interfaces. In-built FDD. Chauvin Arnoux Current Probe E3N 0 to 100 Amp CHA,PROBE-I (1440) Tektronix TDS3054B 500MHz 4 Channel DSO TEK,TDS3054B (1344) TEK,TDS3054 AU MY Fluke 80K-40 High Voltage Probe FLU,80K-40 (1219) Sampling rate 5GS/s. Memory length 10k. Sensitivity 1mV to 10v/div. Time base 1ns to 10s/div. Trigger functions include video. Extensive automatic waveform measurements. Including FFT, TV trigger, advanced analysis (TDS3AAM), and limit testing (TDS3LIM). Battery operation. AU 1 to 40kVDC or peak AC, 28kVAC RMS. Input resistance 1GΩ, division ratio 1,000:1. Note: input impedance of DVM must be 10MΩ or reading will be wrong. Tektronix THS730A 200MHz Battery DSO TEK,THS730A (1360) AU Current probe for oscilloscopes which uses a Hall effect cell for the measurement of DC or AC current. Measures currents from 50mA to 100A peak. A thumbwheel can be used to reset zero for adaption to the measurement environment. The clamp can be used with any measurement instrument which has a BNC input and an impedance of 1MΩ, <100pF. Hewlett Packard A3 flatbed pen plotter with IEEE interface AU/MY HP,7475A-I (1480) Dual channel battery portable 200MHz digital storage oscilloscope with digital multimeter facilities. Maximum sampling rate 1GS/s. Maximum input 640V RMS, maximum float 600V RMS. Waveform processing includes watts calculations. Video trigger. RS232 interface. AU Flatbed pen plotter, A3/A4 format with IEEE interface and HP-GL language compatibility. Tektronix P6015 40kV High Voltage Probe TEK,P6015 (1450) AU Bandwidth 75MHz. Input rating: 40kV pulse, 20kVDC plus peak AC. Derating with frequency applies. Input impedance 100MΩ. Attenuation x 1000. TRAINING FROM TECHRENTALS • • • • TechRentals can offer manufacturer training on high-end Electrical, Telecommunication and NDT testing (fees vary). Training can be done on specific assets as part of the set up and download service (fees apply). Videos are available on the website to assist in operation of certain models. Industry recognised competency training courses. TechRentals offers a number of short courses designed to enhance skills and experience in areas of particular benefit to technical personnel. These courses are recognised throughout industry as providing the necessary capabilities to manage and complete tasks effectively and efficiently. For a listing of all courses, please download the industry competency course planner. This lists additional courses applicable to other areas e.g. power installation, air conditioning, and alarm systems. www.techrentals.com.au/training.html 99 ELECTRONICS www.techrentals.com.au Probes and Accessories cont’d. LCR Meters USB to RS232 Converter USB,232CONVERTER (1490) Hioki 3532-50 5MHz LCR Meter AU USB to RS-232 seriel converter with FTDI chip technology. For converting legacy peripherals to Universal Serial Bus (USB). Connects to a computer via the USB port and provides 1 high speed RS-232 serial port. Suitable for Windows 98, 2000, server 2003, XP, ME, CE, MAC-OS8, OS9, OSX and Linux 4.2 and above. USB type A. HIO,LCR 3532-50 (1290) AU Frequency range 42Hz to 5MHz. 5ms high speed measurements. Basic accuracy of ±0.08%. Memory for 30 sets of measurement conditions, including comparator values. Includes correlation correction function, interactive touch panel operation and enlarged display function. Applications include laboratory use for evaluation of operating characteristics, production line use or R&D. Measurement data captured by a personal computer can be displayed graphically by using standard spreadsheet software. Function Generators See also RF Signal & Sweep Generators on page 14 Stanford Research SR720 LCR Bridge Agilent/HP 33120A 15MHz Function/Arbitrary Generator HP,33120A SR,SR720 (1297) MY Function/Arbitrary Waveform Generator. Frequency 15MHz sine and square waveforms, and 100kHz triangle and ramp waveforms. Gaussian noise to 10MHz. Output into 50ohms 50mV to 10VP-P. AM, FM, FSK, and burst modulation. HP-IB and RS-232C interfaces both standard. Agilent/HP 33220A 20MHz Function/ Arbitrary Generator HP,33220A (1613) AU DC Power Supplies & Loads Frequency range 20MHz sine & square waveforms, 200kHz pulse, triangle, ramp, noise, & DC waveforms. Gaussian noise to 10MHz. Output into 50Ω 10mV to10V P-P. AM, FM, FSK, & burst modulation. Includes option 001 external timebase reference. With optional Benchlink software waveforms can be captured & played back. HPIB, USB, & LAN interfaces. Invensys Intergy Mini Power System 48VDC 2.4kW Supply INV,MPS48DC2400W (8117) AU Frequency range 80MHz sine & square waveforms. 50MHz pulse waveforms with variable rise/fall times. 25MHz arbitrary waveforms, 1MHz triangle & ramp waveforms. White noise to 50MHz. Output into 50Ω 10mVpp to 10Vpp. AM, FM, FSK, & burst modulation. Intuilink software for programming arbitrary waveforms. HPIB & RS232C interfaces. Kikisui PLZ1002W Electronic Load KIK,PLZ1002W (8120) AU Dual channel function/arbitrary waveform generator. Frequency range 1mHz to 25MHz sine, 12.5MHz square & pulse waveforms, 250kHz triangle, ramp, noise & DC waveforms. Arbitrary waveform generation 12.5MHz. Gaussian noise to 25MHz. Output into 50Ω 10mV to 10V P-P. AM, FM, FSK, & burst modulation. HPIB, USB, & LAN interfaces used with included software allows waveforms to be created on PC & imported into unit. Full screen display also allows display & editing of waveforms on unit itself. Sorensen DCS 150V, 20A DC Power Supply SOR,DCS150-20E (8113) AU 0-150V, 20A, 3KW. Applications range from manufacturing test and burn-in of automotive components, avionics electronics, telecommunications and consumer products to beam steering, process control, laboratory R&D use. Remote control via LAN or RS232. Sorensen DCR10-120B DC Power Supply Tektronix 3102/100MHz Arbitrary Function Generator TEK,AFG3102 (1614) AU Voltage range 3 to 110V. Current range 0 to 200A. In-built oscillator provides for dynamic load testing by switching between two different load levels. Load current may be remotely controlled by voltage or resistance signals. Multiple units may be operated in parallel. In-built digital volt/current meter. For DC inputs only. Tektronix 3022/25MHz ArbitraryFunction Generator TEK,AFG3022 (1620) AU Sub-rack mini system 19” rack mount range. For low power telecommunications applications (premises data networks & IP routers, local loop transmission systems & wireless) requiring flexible DC power supplies. Includes integral DC distribution panel and SM30 Series Intergy Supervisory Module. All system settings are fully adjustable in software. Power factor: >0.98@30 to 100% max system current. Efficiency: >89%. Output: voltage 48V, 45 to 60VDC, current@48VDC 50A (2400W). Agilent/HP 33250A 80MHz Function/ Arbitrary Waveform Generator HP,33250A (1618) AU Automatic LCR bridge with 0.05% accuracy. Ranges: inductance 0.0001μH to 99,999H; capacitance 0.0001pF to 99,999μF; resistance 0.0001Ω to 2,000MΩ. Also measures Q & D. Test frequencies 100/120Hz, 1/10/100kHz. Indicates value, deviation, % deviation, or bin number. DC bias internal 0 to 2V, external 0 to 40V. Complete with optional Kelvin leads. SOR,DCR10-120B MY 0 to 10V, 0 to 120A. AU Dual channel function/arbitrary waveform generator. Frequency range 1mHz to 100MHz sine, 50MHz square and pulse waveforms, 1MHz triangle, ramp, noise, and DC waveforms. 50MHz Arbitrary waveform generation. Gaussian noise to 100MHz. Output into 50Ω. 10mV to 10V P-P. AM, FM, FSK, and burst modulation. HPIB, USB, and LAN interfaces used with included software allows waveforms to be created on PC and imported into unit. Full screen display also allows display and editing of waveforms on unit itself. Sorensen DCS60-50, 60V 50A DC Power Supply SOR,DCS60-50 (8114) AU 0 to 60V, 0 to 50A. Max power on a 240V 3ph supply 3kW, 2.5kW on a 1ph 240V supply. On 1ph 50V@50A or 60V@42A. Remote programming. TR Built 12V Battery Supply with Cigarette Power Connector TR,12V-BAT-CIG (8160) AU 12V 20AH battery pack with built-in charger. Has cigarette outlet and banana plug connectors. 10 SETUP AND DOWNLOAD www.techrentals.com.au Save your time and reduce your costs by using our data management services. Learning to operate unfamiliar equipment costs you time and can lead to fundamental errors in data capture processing. There is a better solution - our setup and download service. Our technical staff are equipped and trained to deliver you the downloaded data in a range of suitable output formats including USB drive, CD-ROM, printout, chart and DVD according to your need and the product’s functionality. When you nominate your output preferences and appropriate technical information, the rest is taken care of. The completed files or printouts will be forwarded to you quickly or may be collected at an arranged time. The equipment marked with ‘S’ symbol is available to rent with this service. Fees vary depending on the complexity of operation and the level of detail involved. Data management services are available for many products. Below are some examples of what you can expect. SEWARD ProTag Optima 300 CHK PM30/ PM30PLUS - 3CTs (SEW,PT-300) [Note: Max current is 1000A for PM30] CHK PM40/ PM45 - 4CTs Setup: • Load logo file in printer • Load test settings (CHK,PM30) Setup: • 3P4W(star) or 3P3W(delta) • Max. Current (<1000A or <3000A) • 3P Current only or 3p and Neutral • Log Period and Log Interval • Log Profiling (V,I,PF,kWh,THD) • Event Capture (Sag,Swell,Transient) • Start Log Next Power up Results Downloaded: • Provide database in PATGuard format • Provide CD with PATViewer software including database for end customer Results Downloaded: • Raw Data • PowerView Software • PDF report of V & I Trend Graph • Total kWh Calculation • Exported Data as CSV or Excel files FLUKE DTX1800 (FLU,DTX1800) Setup: • Company name • Site • Tester • Setup of certification test limit • Cable type Results Downloaded: • Raw Fluke Linkware files • Linkware software • PDF report of results FOURIER DAQPRO (FOU,DAQPRO-2) Setup: • How many channels to be measured (Out of 8 channels) • Each channels measurement. eg Voltage - Current etc • Channel scaling • Period of logging to determine logging interval • Logging Interval FLUKE Ti25 Thermal Camera (FLU,TI25) Results Downloaded: • Raw image files • Relevant editing software • Adjust isotherm and emissivity • Standard report of images Results Downloaded: • Data results • DAQPRO viewing software and editing 11 ELECTRONICS www.techrentals.com.au DC Power Supplies & Loads cont’d. Laboratory Calibrators Trio PD35-20 DC Power Supply See also Industrial Process Calibrators on page 48-51 TRI,PD35-20 (8109) AU Output 0 to 35V, 0 to 20A. Constant current, constant voltage. Multiple parallel or series operation. Remote programming of voltage or current by external voltage or resistance. Fluke 5500A Multi Product Calibrator with NATA Calibration FLU,5500A-NATA (4707) Xantrex XFR 600-4 Power Supply XAN,XFR600-4 (8112) AU 2.8kW programmable DC power supply 0 to 600V, 0 to 4A. RS-232 and isolated analogue control options. Xantrek XKW60-50 60V 50A DC Power Supply XAN,XKW60-50 (8115) AU 3 KW DC power supply, 0-60V, 0-50A. Constant current & constant voltage. Isolated analogue programming. Operation of multiple units in series or parallel is possible. Genrad 1433B 1.1MΩ 6 Decade Resistance Spectrum Analysers - Low Frequency GR,1433B-NATA (4702) (AU) Six decades by 1Ω to 1.1MΩ. Accuracy 0.01%. NATA calibrated. See also Spectrum Analyser - High Frequency on page 14 & 16 See also Noise & Sound Analysers on page 72-73 Genrad 1433F 111k 7 Decade Resistance Box GR,1433F-NATA (4704) Agilent/HP 35670A 100kHz Spectrum Analyser HP,35670A (2480) AU Calibrator sources direct voltage & current, alternating voltage and current, with multiple waveforms and harmonics, 2 simultaneous voltage outputs or voltage & current. Simulates power with phase control, resistance, capacitance, thermocouples and RTDs. Selectable ranges include the following outputs VDC from 0 to 1.02kV, VAC from 1mV to 1.02kV with output from 10Hz to 500kHz. AC current from 0.01μA to 11A with output from 10Hz to 10kHz. DC current from 0 to 11A. Resistance values from short circuit to 330MΩ. Capacitance values from 330pF to 1,100μF. Temperature t/c B, C, E, J, K, L, N, R, S, T, U, RTD Pt385 100Ω, Pt3926 100Ω, Pt3916 100Ω, Pt385 200Ω, Pt385 500Ω, Pt385 1kΩ, Ni120 120Ω & Cu427 10Ω. (AU) Seven decades by 0.01Ω to 111k. Accuracy 0.01% +0.002Ω. Useful for platinum resistance thermometer calibration. NATA calibrated. AU Quad channel 122μHz to 102.4kHz spectrum analyser. Up to 1600 line resolution. Displays frequency response, power spectrum, linear spectrum, coherence, cross spectrum, power spectral density, and time. Signal sources: Fixed & swept sine, arbitrary waveform, random noise, chirp. Built-in disk drive. HPIB plotter interface. Bandwidth is 102.4, 51.2 and 25.6KHz for single, dual and quad channel measurements respectively. Genrad 1433-20 11.1111kΩ 6 Decade Resistor GR,1433-20 (MY) Six decades by 0.01Ω per step to 11.1111kΩ. High accuracy 0.01% up to 10MΩ steps. Low temperature coefficient, 5ppm/˚C. Good frequency characteristics, excellent stability (10ppm/yr, 25ppm/3yrs), low zero resistance (1MΩ per decade). May be used for RTD stimulation. Rack mount option. TV Test Equipment Logic Analysers/PROM Programmers See also Network Analysers/Antenna & Cable Test on page 16 & 18 HP 1662A 68 Channel Logic Analyser HP,1662A (1570) Promax TV Explorer Prodig-5 PRO,PRODIG-5 (1727) For the installation, maintenance and surveillance of terrestrial, satellite and cable TV systems. Automatically provides information about the channels available in the network and their quality. Displays analogue and digital channel picture. Includes a high resolution spectrum analyser function and MPEG decoding. Foxtel approved. IceTech LV48 Programmer Promax Prolink 4C Premium Analogue/Digital TV Test Set PRO,PROLINK4C-PREM (1729) AU/MY Timing analysis 250MHz all channels, 500MHz half channels. Transitional: 125MHz all channels, 250MHz half channels. Glitch: 125MHz half channels. State analysis to 100MHz on all channels. Memory 4k/channel, 8k/channel in half-channel modes. 4 clock channels available. HPIB & RS232C ports. In-built DOS format FDD used to load inverse assemblers & transfer measurement data to a computer. Compatible with most HP preprocessors & inverse assemblers. AU ICE,LV48 (1580) AU Eprom programmer for single device with laptop & preloaded software. Programs devices up to 48 pins. AU Measures terrestrial, satellite and cable TV systems including analogue and digital VHF & UHF bands. Built in colour monitor provides measurement readout and can be used to display video signal. Measurement functions include spectrum analysis, direct signal level readout, carrier to noise, channel power, digital carrier to noise, digital bit error ratio (BER) and digital QAM constellation. DVB digital TV channel identifier. Logs to PC and includes software for remote control and channel plan management. Our ex-rental sales list is sent electronically. To receive a copy please email your details to saleslist@techrentals.com.au 12 ELECTRONICS www.techrentals.com.au Gauss/Tesla Meters E & H Field Strength Meters cont’d. FW Bell Gauss/Tesla Meter Holaday HI-3627 Magnetic Field Meter BEL,4190 (1969) AU HOL,HI-3627 (1980) Handheld digital ELF gauss meter. Maintains accuracy regardless of orientation. Applications include detecting magnetic field emissions from overhead AC power lines, video display terminals, office equipment and household appliances. Analogue o/p, data logging, auto range 0.1 to 1999 mG, minimum resolution 0.1mG/.01 uT. AU Three orthogonal field sensors. Dynamic range 0.2mG to 20G. True RMS detection. Frequency range 5Hz to 2kHz with an in-built 30Hz high pass filter. Meets requirements of the Swedish protocol and the IEEE P-1140 protocol. Narda 8616 Radiation Hazard Monitor FW Bell 5180 Gauss/Tesla Meter NAR,8616 (1950) BEL,5180 (1960) Magnetic measuring equipment, portable gaussmeter. Functions include Auto Zero, Min/Max/Peak Hold, Auto Range and Relative Mode. Displays in Gauss, Tesla or Ampere/Meter. With Hall effect transverse probe. Bandwidth DC to 30kHz, ranges 300G to 30kG, resolution 0.1G. Analogue output (±3V FS) and USB interface. Battery operated. Narda NBM-550 E Field Strength Meter NAR,NBM-550 (1930) AU Facilities: store and recall 99 samples, hold. Analogue peak with digital storage. Auto and manual ranges. Automatic reading conversion between different units. (Note 1mT = 10G). Ranges 0 to more than 3T resolution 1mT; 299.9mT resolution 100μT; 29.99mT resolution 10μT; 2.999mT resolution 2μT. Accuracy (at 20C): ± 1%. Frequency range: DC and 15Hz to 10kHz. Functions: DC, DC peak, AC RMS, AC RMS max, & AC peak. EMC & Power Disturbance Simulators Laplace SA1000 EMC Test System LAP,SA1000 (8370) Schaffner 438 30kV Static Discharge Generator See also Radiation Montioring & Protection on page 74 SFN,438 (8375) AU Isotropic RF radiation monitor. E-field & H-field probes spanning 500kHz to 6GHz (E-field) & 5 to 300MHz (H-field). Operates from batteries. Schaffner Automated Step Transformer SFN,INA-6502 (8385) Holaday HI-3004 E Field Strength Meter AU Integrated function unit to Modula system. Power line dips to 0%, 40%, 70% and 80%. Complies with EN/IEC 61000-4-11. Includes EUT power control switch. AU Isotropic broadband field strength meter designed primarily to measure low level fields for EMI/EMC studies. Meter scale calibrated in v/m, with pointer deflection proportional to v 2/m2. Supplied with HSE high sensitivity E-field probe & STE E-Field probe. HSE probe has 4 ranges, 1v/m to 30v/mFS, 0.5 to 1,500MHz. STE probe has 4 ranges 100v/m to 3,000v/mFS, 0.5MHz to 6GHz. Recorder output (0 to 1VDC). Schaffner Modula-6100 Immunity Test System SFN,MODULA 6100 (8380) AU Multifunction generator to simulate electro-magnetic field interference effects for immunity testing in conformity with international, national and in house standards including the new IEC/EN standards. Generates Interference pulses such as burst and surge and power quality simulations. Holaday HI-3604 LF E & H Field Monitor HOL,HI-3604 (1945) AU Generates an electrostatic charge in a range from 2 to 30kV. This instrument is in a ‘gun’ form. Has a removable discharge network which can be interchanged with other (optional) impedance networks. Performs test to IEC61000-4-2 (AKA, IEC 1000-4-2) standards. Holaday HI-3002 E & H Field Strength Meter HOL,HI-3004 (1935) AU Comprises PC controlled spectrum analyser 10kHz to 1.1GHz, SA1020 pre-amplifier, RF200 broadband antenna 30MHz to 1GHz, TTI LISN1600 LISN, and RF100 E-field & H-field probes. Supplied with notebook PC and EMC software. EMC compliance test system. E & H Field Strength Meters HOL,HI-3002 (1940) AU Broadband field strength meter. Applications include measuring field strengths to comply with general safety regulations and actual radiated power. Measuring broadcasting, radar, cell towers, and other transmission sources. Includes GPS position, data logging and voice recording for comments. Hirst GM04 Microprocessor Controlled Gaussmeter HMI,GM04 (1975) AU Radio frequency radiation monitor. Battery operated with analogue meter and recorder output (3VDC full scale). H field probe (8633) has a frequency range of 10 to 300MHz over a range of 0.05 to 100mW/cm2; frequency range up to 200MHz is calibrated to NATA standard. AU AU/MY Low frequency field meter. Designed to evaluate electric and magnetic fields associated with 50Hz power lines. Frequency range 30 to 2,000Hz. Measures magnetic fields from 0.1mG to 20G. Measures electric fields from 1V/meter to 200kV/meter. LCD display. 127 reading data memory. Meets the interim requirements of the Australian Radiation Laboratory for normal levels of AC power exposure. 13