PCVAU1410 DAIKIN GAS HEAT PUMP AIR CONDITIONING SYSTEM Heat Pump / Heat Recover y 50 Hz Air Conditioned Comfort, Powered by Natural Gas. Benefits of Gas Heat Pump (GHP) Daikin's Gas Heat Pump (GHP) air conditioning system is designed to operate primarily on natural gas. GHP systems consume less electrical power than conventional Electrical Heat Pump systems, whilst delivering air conditioned comfort to the modern building. Lower CO 2 Emission Natural gas is used as the main energy source. Natural gas emissions are comparatively lower than other fossil fuels. CO2 emissions This unique gas powered air conditioning system is available both as a Heat Pump and Heat Recovery system to suit a broad range of applications, and when combined with an Electrical Heat Pump system can provide an enhanced value proposition. 100 80 Coal 60 Natural gas Petroleum Reduced Power Consumption What is GHP ? The compressor is the heart of an air conditioner and consumes the most energy. In a Gas Heat Pump (GHP) air conditioner, the compressor is driven by a gas engine using natural gas, whereas an Electric Heat Pump (EHP) uses an electric motor. Indoor Unit Image of heating In GHP system, only the condenser fans and the indoor units consume electricity. In comparison to EHP, the electrical power required to operate GHP is significantly less, thereby enabling the electrical substation and switch gear equipment to be downsized compared to EHP. Power consumption 100 Fans 10 Heat exchanger E HP Compressor * CO2 emissions from coal = 100. * Source: Natural Gas Prospects 2010, 1986/ EA Report on Thermal Power Plant Atmospheric Impact Assessment Technology Demonstration Surveys, March 1990/Institute of Applied Energy GHP * Power consumption of the EHP = 100. Gas Electricity As the load changes during the day, GHP systems are able to match the varying load by adjusting compressor capacity output through engine speed control. GHP EHP Time Heating capacity How is capacity controlled? 01 Rapid and Powerful Heating Outdoor Unit Room temperature Gas engine -10°C Outdoor temperature GHP EHP 10°C The ability to harness the waste heat from the coolant circuit enables rapid and powerful heating performance. This feature also results in less frequent defrost operation for GHP systems. Comparison of heating start speed and heating capacity (image) 02 3 Types available to various application Daikin offers a range of Heat Pump and Heat Recovery systems that are ideally suited for wide range of applications. Heat Pump Standard Series Footprint 1.46 m2 16-25 class Heat Pump Large-capacity Series Centralised control Compact and Light Weight Footprint 1.23 m2 8-13 class Outdoor Unit Lineup Heat Pump Large-capacity Series By controlling both EHP and GHP systems off a common centralised control system, the designer can capitalize on the unique characteristic and features of both systems to deliver an engineered solution that meets the demands of the modern building. Weight : 565 kg 13 class series Control is centralised by one controller. D Weight : 745 kg -NET communication 20 class series Space Saving Design Both systems can be controlled by the centralised controller, which makes it simple to operate. D -NET communication VRV System GHP System Outdoor Unit Lineup Heat Pump Standard Series Combine with VRV system Outdoor Unit Lineup Heat Recovery Series Outdoor Unit Lineup SYSTEM (Electric Heat Pump) Space Saving Design Simultaneous Heating and Cooling Operation Footprint 1.35 m2 20 class Indoor units with constant comfort and unified design Since both systems are connected to the same indoor units, both the comfort level and operation procedures are the same. The designs of front panels, etc. can also be consistent. Footprint 1.68 m2 30 class For Replacement Use Water Cooled Model For Small-sized Building Control Systems Heat Recovery Series Indoor Unit Lineup Footprint 1.68 m2 30 class Capacity range Heat pump standard series Heat pump large-capacity series Heat recovery series 03 22.4 kW 28.0 kW 35.5 kW 45.0 kW 56.0 kW 71.0 kW 85.0 kW 8 class 10 class 13 class 16 class 20 class 25 class 30 class Common models of indoor units Common models of indoor units Common indoor models for both GHP and EHP systems ensure a consistent look for exposed units whilst maintaining similar comfort levels and keeping operational control. Air Treatment Equipment Lineup DAIKIN GAS HEAT PUMP AIR CONDITIONING SYSTEM LINEUP 04 Outdoor Unit Lineup Heat Pump Standard Series Outdoor Unit Lineup Heat Pump – Standard Series 8/10/13/16/20/25 class Compact Design Installation Flexibility Compact, lightweight outdoor units increase installation flexibility. Long piping length 8 / 10 / 13 class series The long piping length provides more design flexibility, to meet the needs of large commercial buildings. 16 / 20 / 25 class series Weight : 565 kg 2,077 mm Max. actual piping length 20 class series 165 m 745 kg 2,077 mm 13 class series Weight : 880 mm 880 mm Max. equivalent piping length 190 m *1 a Max. total piping length 520 m 1,400 mm 1,660 mm First indoor branch Max. level difference Footprint 1.23 m 2 b h e d c i j between the outdoor units and the indoor units Footprint 1.46 m 2 g f k Outdoor unit above indoor unit: Compact size allows the outdoor unit to be transported in an elevator. The compact outdoor unit can be installed on the service balcony of each floor. (Unit: mm) External static pressure: 30 Pa 50 m Outdoor unit below indoor unit: 40 m Colours in the diagram above are merely for identifying pipes referenced with symbols such as a . Actual piping length Example Equivalent piping length Refrigerant piping length 165 m a+f+g+h+i 190 m *1 Total piping length 520 m a+b+c+d+e+f+g+h+i — Between the first indoor branch and the farthest indoor unit 60 m f+g+h+i — Level Difference Example 15 m k If the outdoor unit is above. 50 m j If the outdoor unit is below. 40 m j *1 Elevator Outdoor unit Outdoor unit 8 / 10 / 13 class series 2,077 1,400 * Check the dimensions of the elevator to be used. * Allow the specified space for service. A discharge duct may need to be installed on the outdoor unit. Maximum allowable piping length Maintenance space Balcony *1. Field setting is necessary. 880 Maximum allowable level difference Wide Operating Range Quiet Operation System can operate under a wide range of outdoor temperature. Use of cutting edge technology delivers quiet operations. Enabling the quiet mode further lowers operating noise levels. Heating Cooling −10°C −10°C 18°C (WB) 43°C dB(A) 60 55 54 52 56 57 45 40 Easy Maintenance 10 class 13 class * The outdoor unit enters power-saving operation in quiet mode. Frequent oil change is not required. Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 30,000hrs of operation. * Use the engine oil specified by Daikin. 05 Connection ratio Maximum connection ratio is 130%. Connection ratio 50%–130% Normal mode Quiet mode 50 8 class Between the outdoor units and the indoor units *1. When the equivalent piping length between outdoor and indoor units is 100 m or more, the size of main pipes (both gas-side and liquid-side) must be increased.Refer to the Engineering Data Book. 59 54 Between the indoor units Connection ratio = Total capacity index of the indoor units Capacity index of the outdoor units Outdoor unit combination Model name *1 GYAQ8ANV1 GYAQ10ANV1 GYAQ13ANV1 GYAQ16ANV1 GYAQ20ANV1 GYAQ25ANV1 kW 22.4 28.0 35.5 45.0 56.0 71.0 Class 8 10 13 16 20 25 Capacity index 200 250 320 400 500 630 Total capacity index of connectable indoor units *2 Combination (%) *2 50% 100 125 160 200 250 315 100% 200 250 320 400 500 630 130% 260 325 416 520 650 819 Maximum number of connectable indoor units 13 16 20 26 33 41 *1.Only single outdoor unit can be connected. *2.Total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit. 06 Outdoor Unit Lineup Heat Pump Standard Series Outdoor Unit Lineup Heat Pump – Standard Series 8/10/13/16/20/25 class Operation range INDOOR TEMPERATURE (°CWB) Cooling operation Model GYAQ8ANV1 GYAQ10ANV1 Power supply Gas GYAQ13ANV1 1 Capacity 22.4 28.0 35.5 45.0 56.0 71.0 76,400 95,500 121,000 154,000 191,000 242,000 kcal/h 19,300 24,100 30,500 38,700 48,200 61,100 25.0 31.5 40.0 50.0 63.0 80.0 Btu/h 85,300 107,000 136,000 171,000 215,000 273,000 kcal/h 21,500 27,100 34,400 43,000 54,200 68,800 kW 2 Ivory white (9.9Y8.4/1.2) mm 2,077 2,077 2,077 2,077 2,077 2,077 mm 1,400 1,400 1,400 1,660 1,660 1,660 Depth mm 880 880 880 880 880 880 Height Cooling Power consumption Heating kW 0.34 0.44 0.57 1.26 1.26 1.53 kW 0.42 0.58 0.74 1.11 1.11 1.34 Cooling Fuel gas consumption Heating kW 15.0 19.2 26.4 31.0 41.7 58.5 kW 15.9 20.3 27.0 32.7 42.0 57.2 Scrollx1 Scrollx1 Scrollx1 Scrollx2 Scrollx2 Scrollx2 Type Type Propeller fan Number of units Motor output W Airflow rate m3/min 2 2 2 2 2 2 275x2 275x2 275x2 350+600 350+600 600x2 167 194 213 346 346 388 15.9 15.9 15.9 Drive Refrigerant Piping Direct drive Liquid mm Gas 9.5 9.5 mm 19.1 22.2 25.4 28.6 28.6 31.8 inch R3/4 R3/4 R3/4 R3/4 R3/4 R3/4 Exhaust vent outside dia. mm 80 80 80 100 100 100 Drain pipe for exhaust inside dia. mm 30 30 30 30 30 30 565 565 565 745 745 755 R-410A R-410A R-410A R-410A R-410A R-410A 11.0 11.0 11.0 11.5 11.5 11.5 62 kg Type Charge kg Engine Lubricant Type Engine coolant 14 -10 43 -10 0 10 20 30 OUTDOOR TEMPERATURE (°CDB) 40 OPERATION 10 10 -30 -10 -20 -10 18 0 10 20 OUTDOOR TEMPERATURE (°CWB) Options Option name Cool/Heat selector *1 Fixing box Harness kit for Cool/Heat Selector *2 REFNET header Model GYAQ8ANV1 GYAQ10ANV1 GYAQ16ANV1 GYAQ20ANV1 GYAQ25ANV1 KRC19-26A KJB111A AGKRC19E1 KHRP26M22H (Max. 4 branch) KHRP26M33H (Max. 8 branch) KHRP26M22H (Max. 4 branch) KHRP26M33H (Max. 8 branch) KHRP26M72H (Max. 8 branch) KHRP26A22T KHRP26A33T KHRP26A22T KHRP26A33T KHRP26A72T Distributive piping REFNET joint GYAQ13ANV1 KHRP26M22H KHRP26M33H KHRP26M72H KHRP26M73H 4 8 8 8 branch) branch) branch) branch) KHRP26A22T KHRP26A33T KHRP26A72T KHRP26A73T KHRP26M73TP KHRP26M73HP Pipe size reducer Antivibration mount *3 Air direction adjuster *4 Deodorizer kit (Max. (Max. (Max. (Max. K-GBM13B70 AGFJ280E1 AGBJ280E1 K-GBM13B71 AGFJ560E2 AGBJ560E1 *1. The Cool/Heat Selector is required when selecting cool/heat mode from the outdoor unit. *2. The harness kit is required when using the Cooling/Heating Selector. *3. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof. The specified antivibration mount must be used. Otherwise abnormal vibration may occur. *4. The Air direction adjuster is designed to prevent snow from accumulating on the air outlet of the outdoor unit and to change the air direction to the front or back if the air outlet is blocked by an obstacle. If The Air direction adjuster is installed, the operation sound may increase slightly depending on ambient conditions. Aisin Coolant S Freezing temperature -35 Normal mode Sound pressure level Quiet mode dB(A) 54 56 59 56 59 dB(A) 52 54 57 54 57 60 Piping length;equivalent/actual m 190/165 190/165 190/165 190/165 190/165 190/165 Height difference between O/U is above m indoor and out door units O/U is below m 50 50 50 50 50 50 40 40 40 40 40 40 Height difference between indoor units m 15 15 15 15 15 15 13 16 20 26 33 41 50-130 50-130 50-130 50-130 50-130 50-130 Note: 10 RANGE FOR CONTINUOUS OPERATION RANGE FOR CONTINUOUS 20 Aisin Gas Engine Oil L-10000G Type Connectable indoor units 07 12.7 Fuel gas pipe Weight Refrigerant 20 28 * If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit. Dimensions Width Fans 24 30 GYAQ25ANV1 Btu/h Casing colour (Munsell no.) Compressor 30 Natural gas kW Heating GYAQ20ANV1 1- phase , 230 V , 50 Hz Type Cooling GYAQ16ANV1 Heating operation INDOOR TEMPERATURE (°CDB) Specifications number capacity % 1 Indoor temp.: 27 °CDB, 19°CWB / outdoor temp.: 35 °CDB / Equivalent piping length: 7.5 m, level difference: 0 m 2 Indoor temp.: 20 °CDB / outdoor temp.: 7°CDB, 6°CWB/ Equivalent piping length: 7.5 m, level difference: 0 m 08 Outdoor Unit Lineup Space Saving Design Installation flexibility Space saving design allows for flexible installation. Long piping length Weight : Outdoor Unit Lineup Heat Pump Large-capacity Series Heat Pump – Large Capacity Series 30 class The long piping length provides more design flexibility, which can match even large-sized buildings. 1080 kg 2,170 mm Max. actual piping length Footprint 1.68 m2 800 mm Max. equivalent piping length 170 m 200 m a Max. total piping length 640 m 2,100 mm The compact outdoor unit can be installed on the service balcony of each floor. External static pressure: First indoor branch c Maintenance space *1. Field setting is necessary. Wider Operating Range System can operate under a wider range of outdoor temperature. Heating −21°C 18°C (WB) Cooling −10°C 46°C Quiet Operation k Colours in the diagram above are merely for identifying pipes referenced with symbols such as a . dB(A) 65 60 Maximum allowable piping length Maximum allowable level difference Use of cutting edge technology delivers quiet operations. Enabling the quiet mode further lowers operating noise levels. i 50 m Actual piping length Balcony e d between the outdoor units and the indoor units *1 * Allow the specified space for service. A discharge duct may need to be installed on the outdoor unit. b h j Max. level difference 30 Pa Outdoor unit g f Example Equivalent piping length Refrigerant piping length 170 m a+f+g+h+i 200 m Total piping length 640 m a+b+c+d+e+f+g+h+i — Between the first indoor branch and the farthest indoor unit 90 m *1 f+g+h+i — Level Difference Example Between the indoor units 15 m *1 k Between the outdoor units and the indoor units 50 m j *1.When the piping length between the indoor branch and the farthest indoor unit is 40 m or more, the maximum allowable level difference between the indoor units is decreased.Refer to the Engineering Data Book. 62 59 55 Normal mode Connection ratio Quiet mode Maximum connection ratio is 130%. Connection ratio 50%–130% 50 45 30 class * The outdoor unit enters power-saving operation in quiet mode. Easy Maintenance Frequent oil change is not required. Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 20,000hrs of operation. Connection ratio = Total capacity index of the indoor units Capacity index of the outdoor units Outdoor unit combination Model name *1 GYAQ30ANV1 kW 85.0 Class 30 Capacity index 750 Total capacity index of connectable indoor units *2 Combination (%) *2 50% 375 100% 750 130% 975 Maximum number of connectable indoor units 48 *1.Only single outdoor unit can be connected. *2.Total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit. * Use the engine oil specified by Daikin. 09 10 Outdoor Unit Lineup Heat Pump – Large Capacity Series 30 class Specifications Operation range GYAQ30ANV1 Power supply Gas 1- phase , 230 V , 50 Hz Type 1 Capacity 290,000 kcal/h 73,100 Btu/h 2 kcal/h Casing colour (Munsell no.) 95.0 324,000 81,700 Ivory white(5Y7.5/1) mm 2,170 Dimensions Width mm 2,100 Depth mm 800 Cooling Power consumption Heating kW 1.66 kW 1.51 Cooling Fuel gas consumption Heating kW 67.7 Height Compressor kW 66.3 Type Scrollx2 Type Propeller fan Number of units Fans 3 Motor output W Airflow rate m3/min Drive 570 Direct drive mm Gas mm 31.8 Fuel gas pipe inch R3/4 Exhaust vent outside dia. mm 60.5 Drain pipe for exhaust inside dia. mm Weight Refrigerant 370x3 Liquid Refrigerant Piping 20 10 (Note 1) RANGE FOR CONTINUOUS OPERATION 14 -10 -10 46 0 10 20 30 OUTDOOR TEMPERATURE (°CDB) 40 50 30 RANGE FOR CONTINUOUS OPERATION 20 15 -21 18 10 -30 -20 -10 0 10 20 OUTDOOR TEMPERATURE (°CWB) Note 1: An optional air guard is required. * If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit. 85.0 Btu/h kW Heating 25 30 Natural gas kW Cooling 30 Outdoor Unit Lineup Heat Pump Large-capacity Series Model Heating operation INDOOR TEMPERATURE (°CDB) INDOOR TEMPERATURE (°CWB) Cooling operation kg Type 19.1 Option name Cool/Heat selector Fixing box REFNET header Distributive piping REFNET joint Pipe size reducer Antivibration mount *1 Air direction adjuster Air guard Exhaust extension adaptor Exhaust extension external drain filter Water discharge kit External contact output harness *2 Model GYAQ30ANV1 KRC19-26A KJB111A KHRP26M22H KHRP26M33H KHRP26M72H KHRP26M73H (Max. (Max. (Max. (Max. 4 8 8 8 branch) branch) branch) branch) KHRP26A22T KHRP26A33T KHRP26A72T KHRP26A73T KHRP26M73TP , KHRP26M73HP YGAS850J1 FKA850H ARD850H HA850H DFB19E RGA850H1 OSH850J *1. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof. The specified antivibration mount must be used. Otherwise abnormal vibration may occur. *2. Only use of input contact point is possible. Use of output contact point is not possible. (only for 30 class heat pump) 15 1080 R-410A Charge kg Engine Lubricant Type 11.8 Yanmar genuine GHP oil Engine coolant Type Sound pressure level Normal mode dB(A) Quiet mode dB(A) Yanmar genuine LLC (for GHP) Freezing temperature Piping length;equivalent/actual -35 m 62 59 200/170 Height difference between O/U is above m indoor and out door units O/U is below m 50 Height difference between indoor units m 15 Connectable indoor units Options number capacity 50 48 % 50-130 Note: 1 Indoor temp.: 27 °CDB, 19 °CWB / outdoor temp.: 35 °CDB / Equivalent piping length: 7.5 m, level difference: 0 m 2 Indoor temp.: 20 °CDB / outdoor temp.: 7°CDB, 6°CWB/ Equivalent piping length: 7.5 m, level difference: 0 m 11 12 Outdoor Unit Lineup Heat Recovery Series 20/30 class Heat Recovery Operation Large Capacity & Space Saving Design Simultaneous heating and cooling operation within refrigerant system Space –saving outdoor units allow flexible installation. BS unit Indoor unit (Heating) 800 mm Indoor unit (Cooling) 1,690 mm Heat radiation operation (all cooling operation) BS Unit Heat radiation cooling cooling cooling Indoor Unit For example, the heat recovery system can meet the following needs: 2,100 mm Footprint 1.35 m2 Heat recovery operation mode Outdoor Unit 1040 kg 2,170 mm 800 mm Heat recovery operation! (A) Weight : 860 kg 2,170 mm By adding suction gas piping and a BS unit (sold separately), simultaneous heating and cooling operation can be provided by a single system. BS unit 30 class series Weight : BS unit High and low pressure gas piping Suction gas piping Liquid piping Outdoor unit 20 class series Footprint 1.68 m2 The compact outdoor unit can be installed on the balcony of each floor. cooling External static pressure: Heat radiation tendency heat recovery operation (B) cooling, ( mainly part heating operation ) Heat radiation Outdoor Unit Lineup Heat Recovery Series In mainly cooling, partly heating mode, the system recycles heat exhausted from the cooling operation to use for heating. In mainly heating, partly cooling mode, the system uses cooled post-heating operation refrigerant for cooling. Efficiency improves when simultaneous operation is performed. Heating Window cooling cooling cooling Cooling Cooling BS unit *1 * Allow the specified space for service. A discharge duct may need to be installed on the outdoor unit. heating Heat recovery operation 30 Pa Outdoor unit Office building in transition period to winter (cooling and heating operation) The difference between heat generated from the interior zone and the cool air load in the perimeter zone is large. (C) Maintenance space Balcony *1. Field setting is necessary. cooling cooling heating heating Heat absorption tendency heat recovery operation (D) Heat absorption Cooling Heating heating, ( mainly part cooling operation ) BS unit cooling heating heating Hallway heating Wide Operating Range Quiet Operation System can operate under a wide range of outdoor temperature. Use of cutting edge technology delivers quiet operations. Enabling the quiet mode further lowers operating noise levels. Hotel in transition period Heat absorption operation Indoor units can independently meet the need for cooling and heating. (all heating operation) (E) heating heating heating heating Heating −11°C 18°C (WB) Cooling −10°C 43°C Note: Operation modes (A) and (E) are applicable when the outdoor temperature is 35°C and 7°C respectively; The other modes are applicable under typical outdoor conditions. dB(A) 65 60 55 62 58 59 55 Normal mode Quiet mode 50 Thanks to the heat recovery system. 13 * The outdoor unit enters power-saving operation in silent mode. 45 20 class Automatic cooling-heating switching Heat recovery saves energy The system automatically switches the operation mode to cooling or heating based on the difference between the set temperature and the indoor temperature. It is not necessary to use the remote controller to switch the operation mode to cooling or heating. Operation efficiency can be further increased by recovering cooling exhaust heat within the same system and using it effectively as heating energy. 30 class Easy Maintenance Heating Cooling Cooling exhaust heat is recovered as heating energy. Frequent oil change is not required. Engine oil needs to be topped up periodically to recommended operational uses. Oil change only required after 20,000hrs of operation. * Use the engine oil specified by Daikin. 14 Outdoor Unit Lineup Heat Recovery Series 20/30 class Installation Flexibility Specifications Long piping length The long piping length provides more design flexibility, which can match even large-sized buildings. Max. actual piping length Max. equivalent piping length 170 m 200 m 640 m First indoor branch Max. level difference between the outdoor units and the indoor units g f b Model h d c GYEQ20AN Power supply e Gas i Natural gas Type kW Cooling j 1 Capacity 50 m k 56.0 85.0 Btu/h 191,000 290,000 kcal/h 48,200 73,100 kW Heating 2 63.0 95.0 Btu/h 215,000 324,000 kcal/h 54,200 Casing colour (Munsell no.) Maximum allowable piping length Actual piping length Example Refrigerant piping length 170 m a+f+g+h+i 200 m Total piping length 640 m a+b+c+d+e+f+g+h+i — f+g+h+i — Between the first indoor branch and the farthest indoor unit 90 m* 1 Equivalent piping length mm 2,170 2,170 mm 1,690 2,100 Depth mm 800 800 Cooling Power consumption Heating kW 1.17 1.77 kW 1.10 1.57 Cooling Fuel gas consumption Heating kW 47.4 67.7 kW 46.6 66.3 Scrollx2 Scrollx2 Compressor Type Type Propeller fan Number of units Maximum allowable level difference Level Difference Example Between the indoor units 15 m*1 k Between the outdoor units and the indoor units 50 m j Fans 50%–130% Connection ratio = Total capacity index of the indoor units Capacity index of the outdoor units 20 30 Capacity index 500 750 Total capacity index of connectable indoor units *2 Combination (%) *2 50% 250 375 *1.Only single outdoor unit can be connected. *2.Total capacity index of connectable indoor units must be 50%-130% of the capacity index of the outdoor unit. 100% 500 750 130% 650 975 Maximum number of connectable indoor units 32 48 570 15.9 19.1 28.6 31.8 mm 22.2 28.6 Fuel gas pipe inch R3/4 R3/4 Exhaust vent outside dia. mm 60.5 60.5 kg Refrigerant Type Charge kg 15 15 860 1040 R-410A R-410A 11.8 Engine Lubricant Type 11.8 Yanmar genuine GHP oil Type Yanmar genuine LLC (for GHP) Freezing temperature -35 Sound pressure level Quiet mode dB(A) 58 dB(A) 55 59 Piping length;equivalent/actual m 200/170 200/170 Height difference between O/U is above m indoor and out door units O/U is below m 50 50 50 50 Height difference between indoor units m 15 15 Connectable indoor units Note: 15 380 mm Normal mode outdoor unit combination Class 370x3 mm Weight Connection ratio 3 370x2 Direct drive Discharge Engine coolant 56.0 85.0 m3/min Drain pipe for exhaust inside dia. mm Maximum connection ratio is 130%. GYEQ20AN GYEQ30AN Airflow rate Refrigerant Suction Piping kW W Liquid 1. When the piping length between the indoor branch and the farthest indoor unit is 40 m or more, the maximum allowable level difference between the indoor units is decreased.Refer to the Engineering Data Book. Model name *1 Motor output 2 Drive Connection ratio 81,700 Ivory white(5Y7.5/1) Dimensions Width Height Colours in the diagram above are merely for identifying pipes referenced with symbols such as a . GYEQ30AN 1- phase , 200 V , 50 Hz Outdoor Unit Lineup Heat Recovery Series a Max. total piping length number capacity % 62 32 48 50-130 50-130 1 Indoor temp.: 27 °CDB, 19 °CWB / outdoor temp.: 35 °CDB / Equivalent piping length: 7.5 m, level difference: 0 m 2 Indoor temp.: 20 °CDB / outdoor temp.: 7 °CDB, 6 °CWB/ Equivalent piping length: 7.5 m, level difference: 0 m 16 Outdoor Unit Lineup Heat Recovery Series 20/30 class BS Unit: Specifications Operation range Heating operation 25 20 10 (Note 1) RANGE FOR CONTINUOUS OPERATION 14 -10 -10 43 0 10 20 30 OUTDOOR TEMPERATURE (°CDB) 40 30 30 RANGE FOR CONTINUOUS OPERATION 20 15 18 -11 10 -30 -20 -10 0 10 20 OUTDOOR TEMPERATURE (°CWB) Note 1: An optional air guard is required. * If the unit is used out of the operation temperature range (especially at high outdoor temperature), it may malfunction, or the protection circuit may trip and deactivate the unit. MODEL BSGQ100PV1 Power supply Total capacity index of connectable indoor units No. of connectable indoor units Model GYEQ20AN GYEQ30AN KRC19-26A KJB111A REFNET header KHRP25M33H (Max. 8 branch) KHRP25M72H (Max. 8 branch) KHRP25M73H (Max. 8 branch) REFNET joint KHRP25A22T,KHRP25A33T (KHRP25A72T+KHRP25M72TP) (KHRP25A73T+KHRP25M73TP) Distributive piping Antivibration mount *1 Air direction adjuster Air guard Exhaust extension adaptor Exhaust extension external drain filter Water discharge kit External contact output harness 20 to 100 More than 100 but 160 or less More than 160 but 250 or less Max. 5 Max. 8 Max. 8 Casing Galvanised steel plate Dimensions (HXWXD) Option name Cool/Heat selector Fixing box YGAS560J1 FKA560H ARD560H Piping connections Indoor Liquid Unit Gas YGAS850J1 FKA850H ARD850H Notes: mm mm Liquid Outdoor mm Suction gas Unit High and low pressure gas Machine weight Sound level BSGQ250PV1 1 No. of branches Outdoor Unit: Options BSGQ160PV1 1-phase, 220-240 V, 50 Hz 207x388x 326 9.5 (Brazing) 1 9.5 (Brazing) 9.5 (Brazing) 15.9 (Brazing) 1 15.9 (Brazing) 2 22.2 (Brazing) 3 9.5 (Brazing) 9.5 (Brazing) 9.5 (Brazing) 15.9 (Brazing) 15.9 (Brazing) 2 22.2 (Brazing) 3 12.7 (Brazing) 12.7 (Brazing) 2 kg 12.0 12.0 dB(A) 42 (32) 4 43 (32) 4 Outdoor Unit Lineup Heat Recovery Series 30 INDOOR TEMPERATURE (°CDB) INDOOR TEMPERATURE (°CWB) Cooling operation 19.1 (Brazing) 3 15.0 44 (34) 4 1 When connecting with an indoor unit with a capacity index between 20 and 50, connect the attached pipe to the field pipe. (Braze the connection between the attached and field pipe.) 2 When connecting with indoor units with total capacity indexes between 150 and 160, connect the attached pipe to the field pipe. (Braze the connection between the attached and field pipe.) 3 When connecting with indoor units with a capacity index of 200, or with total capacity indexes between 160 and 200, connect the attached pipe to the field pipe. (Braze the connection between the attached and field pipe.) 4 Figures in brackets ( ) indicate sound levels when the all indoor units connected to the BS unit are not operating but other indoor units within the same system are operating. HA850H DFB19E RGA850H1 OSH850J *1. Use an antivibration mount when operating noise or vibration could cause problems in lower floors or nearby rooms as a result of installing the outdoor unit on the roof. The specified antivibration mount must be used. Otherwise abnormal vibration may occur. 17 18 Indoor Unit Lineup Daikin’s indoor units are available in 90 models of 16 types to deliver comfortable air conditioning whilst matching the varied requirements of the modern office and residential building. Ceiling Suspended Type Wall Mounted Type Slim body with quiet and wide airflow Stylish flat panel design harmonised with your interior décor Lineup FXFQ-SVM Ceiling Mounted Cassette (Round Flow) Type FXFQ-PVE To be launched in June 2014 Presence of people and floor temperature can be detected to provide comfort and energy savings Ceiling Mounted Cassette (Compact Multi Flow) Type Quiet, compact, and designed for user comfort Floor Standing Type 360 airflow improves temperature distribution and offers a comfortable living environment. 4-Way Flow Ceiling Suspended Type This slim and stylish indoor unit achieves optimum air distribution, and can be installed without the need for ceiling cavity. Concealed Floor Standing Type Suitable for perimeter zone air conditioning Indoor units (kW) 2.2 2.8 3.6 4.5 FXFQ-SVM To be launched in June 2014 Ceiling Mounted Cassette (Double Flow) Type Thin, lightweight, and easy to install in narrow ceiling spaces Slim Ceiling Mounted Duct Type FXDQ-PBVE FXFQ-PVE Ceiling Mounted Cassette Corner Type 8 9 11.2 14 16 145 16.2 145 180 20 180 22.4 28 Ceiling Mounted Built-in Type FXSYQ-MVE FXDQ-NBVE Ceiling Concealed (Duct) Type 7.1 Slim design for flexible installation Ceiling Mounted Built-in Slim design, quietness and static pressure switching 5.6 Indoor Unit Lineup Ceiling Mounted Cassette (Round Flow with Sensing) Type Ceiling Concealed (Duct) FXSYQ-MVE FXDYQ-M(A)V1 Highly flexible for various application Ceiling Mounted Duct Type FXDYQ-M(A)V1 High static pressure offers flexible duct design that blends in with any interior décor in stores and offices 19 High external static pressure allows flexible installations This FXUQ model is not compatible both Heat Pump 30 class and Heat Recovery systems. 20 Indoor Unit Lineup Ceiling Mounted Cassette (Round Flow with Sensing) Type Airflow block function *3 Auto airflow rate mode + Auto airflow direction mode FXFQ25S/FXFQ32S/FXFQ40S Floor temperature is detected and over cooling prevented. FXFQ50S/FXFQ63S/FXFQ80S Without sensing function FXFQ100S/FXFQ125S To be launched in June 2014 With sensing function Room temperature is calculated as 27°C in the area which is in the vicinity of the person. Infrared presence sensor 24°C near floor The floor temperature, which is lower than near the ceiling, is detected. Energy savings The temperature near the person is automatically calculated by detecting the temperature of the floor. Energy is saved, because the area around the feet does not get too cold. Indoor unit offers 360° airflow discharges air in all directions with more uniform temperature distribution. Sensing sensor mode Infrared floor sensor The sensor detects the floor temperature and automatically adjusts operation of the indoor unit to reduce the temperature difference between the ceiling and the floor. Individual airflow direction control Thanks to the individual airflow direction control function, airflow direction can be individually adjusted for each air discharge outlet. 5 directions of airflow and auto-swing can be selected with wired remote controller BRC1E62, which realises the optimum air distribution. Individual airflow direction example case 21 Position 2 Swing Comfortable airflow Airflow rate automatically increases during hot or cold periods (when there is a large difference with set temperature), and operation is rapidly performed for cooling or heating.When the difference with set temperature becomes small, drafts are prevented by automatically reducing airflow rate, and raising the flap to a horizontal position during cooling operation. Dead spot of airflow Energy efficiency has been improved thanks to the adoption of a new heat exchanger with smaller tubes, DC fan motor and DC drain pump motor. Low operation sound level FXFQ-S Sound level (H/M/L) 25/32 40 50 63 80 100 125 30/28.5/27 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35 Control of airflow rate can be selected from 3-step control, which provides comfortable airflow. Auto airflow rate control can be selected with wired remote controller BRC1E62. Drain pump is equipped as standard accessory with 850 mm lift. Airflow block function prevents uncomfortable drafts by reducing air velocity to approx. 0.3m/s.*4 Airflow block for cabinet side Also can support such this case New airflow block function prevents uncomfortable drafts by reducing air velocity. It can be set using the BRC1E62 remote controller. There is no need for sealing material of air discharge outlet (option). This function only works when all-round flow is used. It cannot be used when sealing material is used in the air discharge outlet (option). Easy setup with remote controller Sensing sensor low mode *1. 2 When there are no people in a room, the set temperature is shifted automatically. 850 mm Example: • Cooling setpoint: 26°C • Shift temperature: 1.0°C Setpoint (°C) Detecting the average temperature of indoor floor Position 3 Automatic control using the temperature near the person as the room temperature. 30°C near ceiling Dual sensors detect the presence of people and floor temperature to provide comfortable air-conditioning and energy savings. Position 0 Area around feet gets too cold because air conditioner continues until the temperature near the ceiling reaches the set temperature. Room temperature is detected as 30°C. 20°C near floor Presence of people in 4 areas Airflow block air velocity approx. 0.3m/s*4 30°C near ceiling Presence of people and floor temperature can be detected to provide comfort and energy savings The sensor detects human presence and adjusts the airflow direction automatically to prevent drafts. Energy saving control can be performed when no people are detected. Total comfort by individual airflow direction control and newly-equipped “airflow block function” Indoor Unit Lineup Sensing function 28 27 26 27°C 26°C Occupied • Shift time: 30 min. • Limit cooling temperature: 30°C 28°C Unoccupied After 30 min After another 30 min 26°C Automatically reverts when people return. Horizontal flow The airflow block function is useful when rearranging the room layout. Time If people do not return, the air conditioner will raise the temperature 1°C every 30 minutes and then operate at 30°C. Shift temperature and time can be selected from 0.5 to 4°C in 0.5°C increments and 15, 30, 45, 60, 90 or 120 minutes respectively with remote controller. Airflow block Airflow block 500 mm*5 Wall *3. Works in one direction only. *4. In case of FXFQ63S type (Data is based on Daikin research.) *5. A gap of 1500 mm is required if the air block function is not used. Sensing sensor stop mode *1. 2 When there are no people in a room, the system stops automatically. Absent stop time can be selected from 1 to 24 hrs in 1 hr increments with remote controller. *1. These functions are not available when using the group control system. *2. User can set these functions with remote controller. 22 Indoor Unit UnitsLineup Ceiling Mounted Cassette (Compact Multi Flow) Type Ceiling Mounted Cassette (Round Flow) Type FXFQ25P/FXFQ32P/FXFQ40P FXZQ20M / FXZQ25M / FXZQ32M FXFQ50P/FXFQ63P/FXFQ80P FXZQ40M / FXZQ50M FXFQ100P/FXFQ125P 360° airflow improves temperature distribution and offers a comfortable living environment. The industry’s first* Round Flow Ceiling Mounted Cassette type offers 360° airflow with improved temperature distribution. 4-way flow Quiet, compact, and designed for user comfort Dimensions correspond with 600 mm X 600 mm architectural module ceiling design specifications. Low operation sound level Round Flow (240 V)(dB(A)) FXZQ-M 20/25 32 40 50 Sound level (H/L) 32/26 34/28 37/29 42/35 Comfortable airflow 1 There are much fewer areas of uneven temperature. Wide discharge angle: 0° to 60° Indoor Unit Lineup There are areas of uneven temperature. Auto swing * As of April 2004, the release date for Japan. The light weight unit at 19.5 kg for FXFQ25-50P models makes installation easy. Drain pump is equipped as a standard accessory with a 850 mm lift. A modern sophisticated decoration panel has been applied, with a panel surface that has been treated with a dirt-repellant coating. Treated surface Untreated surface Dirt and grime • Condition after exposure to the smoke of 600 3 cigarettes in 1 m enclosed space. Resists soiling Control of the airflow rate can be selected from 3-step control. Low operation sound level FXFQ-P 25/32 40 50 (dB(A)) 63 80 100 125 Sound level 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 (HH/H/L) Example of airflow patterns: 0° 850 mm All-round flow 60° 60° Fixed angles: 5 levels An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours. The horizontal louvres prevent dew condensation. Their non-flocking surfaces, which repel dirt, are easy to clean. The air filter has an anti-mould and antibacterial treatment that prevents the growth of mould generated from dust or moisture that may adhere to the filter. 4-way flow 3-way flow 0° 0° 60° Drain pump is equipped as standard accessory with 750 mm lift. 60° *Angles can be also set on site to prevent drafts (0°-35°) or soiling of the ceiling (25°-60°), other than standard setting (0°-60°). 2 2-, 3-, and 4-way airflow patterns are available, enabling installation in the corner of a room. 750 mm L-shaped 2-way flow All-round flow is available, as well as 2-way to 4-way flows, so you can choose the most suitable airflow pattern depending on location or room layout. Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet. 23 0° 4-way flow 3-way flow L-shaped 2-way flow *For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close each unused outlet. 24 Indoor Unit UnitsLineup Ceiling Mounted Cassette (Double Flow) Type 4-Way Flow Ceiling Suspended Type FXCQ20M/FXCQ25M/FXCQ32M FXCQ40M/FXCQ50M/FXCQ63M FXUQ71A/FXUQ100A FXCQ80M/FXCQ125M This model is not compatible both Heat Pump 30 class and Heat Recovery systems. This slim and stylish indoor unit achieves optimum air distribution, and can be installed without the need for ceiling cavity. Unit body and suction panel adopted round shapes and realised a slim appearance design. The unit can be used for various locations such as the ceilings with no cavity and bare ceilings. Thin, lightweight, and easy to install in narrow ceiling spaces The thin unit (only 305 mm high) can be installed in a ceiling space as narrow as 350 mm. All models feature a compact design with a depth of only 600 mm. Indoor Unit Lineup 305 mm (When a high-efficiency filter is attached, the unit's height is 400 mm.) Flaps close automatically when the unit stops, which gives a simple appearance. Unified slim height of 198 mm for all models that gives the unified impression even when models with different capacities are installed in the same area. 198 mm With adoption of the individual flap control, airflow direction adjustment can be individually set for each air outlet. 5 directions of airflow and auto-swing can be selected with wired remote controller BRC1E62, which realises the optimum air distribution. Low operation sound level Control of the airflow rate has been improved from 2-step to 3-step control. Auto airflow rate control can be selected with wired remote controller BRC1E62. Energy efficiency has been improved thanks to the adoption of a new heat exchanger with smaller tubes, DC fan motor and DC drain pump motor. Drain pump is equipped as a standard accessory, and the lift height has been improved from 500 mm to 600 mm. Depending on installation site requirements or room conditions, 2-way, 3-way and 4-way discharge patterns are available. 4-way flow 3-way flow (240 V)(dB(A)) FXCQ-M 20 25/32 40/50 63 80 125 Sound level (H/L) 34/29 36/30 37/32 39/34 41/36 46/40 Designed with higher airflow suitable for high ceiling application up to 3 metres. Providing 2 different settings of standard and ceiling soiling prevention, the auto swing mechanism realises even distribution of airflow and room temperature. Drain pump is equipped as standard accessory with 600 mm lift. Two types of optional high-efficiency filter are available (65% and 95%, colourimetric method). A long-life filter (maintenance free up to one year*) is equipped as standard accessory. * 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3 Individual airflow direction example case Position 0 Position 2 600 mm Position 3 25 Swing L-shaped 2-way flow Major maintenance work can be performed by removing the panel. A flat-type suction grille and a detachable blade make cleaning easy. 26 Indoor Unit Lineup Slim Ceiling Mounted Duct Type Ceiling Mounted Cassette Corner Type Slim design, quietness and static pressure switching FXKQ25MA/FXKQ32MA FXKQ40MA/FXKQ63MA Suited to use in drop-ceilings! Slim design for flexible installation Providing 3 different settings of standard, draft prevention and ceiling soiling prevention, the auto swing mechanism realises even distribution of airflow and room temperature. (m) 3 Min.195 mm Panel spacer 20 mm Single-flow type allows effective air discharge from corner or from drop-ceiling. Drain pump is equipped as standard accessory with 500 mm lift. 2 28˚C 32˚C 30˚C 26˚C Only 700 mm in width and 23 kg in weight, this model is suitable to install in limited spaces like drop-ceilings in hotels. Great for hotel use! 22˚C 20˚C 1 2 3 4 5 Only 6 (m) 200 mm 700 mm 200 mm 900 mm * 1,100 mm in width for the FXDQ63NB model. Front discharge is possible with an air discharge unit (option), which allows the installation in the drop-ceiling or sagging wall. Suspension bolt* Air filter 240 mm AIR Main body 500 mm Only 200 mm in height, this model can be installed in rooms with as little as 240 mm depth between the drop-ceiling and ceiling slab. 24˚C 1 0 FXDQ40NB /FXDQ50NB / FXDQ63NB Indoor Unit Lineup Slim body needs only 220 mm space above the ceiling. If you use a panel spacer (option), the unit can be installed in the minimum space of 195 mm. FXDQ20PB /FXDQ25PB /FXDQ32PB Discharge grille * AIR Downward discharge Suction grille * * To be obtained locally External static pressure selectable by remote controller switching make this indoor unit a very comfortable and flexible model. Air discharge grille (Option) 10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models. 15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models. Set for front discharge using a suspended ceiling. Drain pump is equipped as standard accessory with 750 mm lift. Main body Air discharge grille (Option) Downward discharge is shut off and air is blown straight out (front discharge). A long-life filter (maintenance free up to one year*) is equipped as standard accessory. Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level 750 mm (dB(A)) FXDQ-PB/NB 20/25/32 40 50 63 Sound level (HH/H/L) 33/31/29 34/32/30 35/33/31 36/34/32 Ceiling * The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). * Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa. * 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3 27 28 Indoor Unit UnitsLineup Ceiling Concealed (Duct) Type Ceiling Mounted Built-in Type FXSYQ20M/FXSYQ25M/FXSYQ32M FXSYQ40M/FXSYQ50M /FXSYQ63M FXSYQ80M/FXSYQ100M FXSYQ125M FXDYQ80MA/FXDYQ100MA FXDYQ125MA/FXDYQ145MA FXDYQ180M/FXDYQ200M FXDYQ250M High static pressure offers flexible duct design that blends in with any interior décor in stores and offices Highly flexible for various application Installation examples ( Optional parts) Highly flexible installation is possible with a complete lineup of optional kits to satisfy various needs, such as the design concept, interior decoration and so on. Standard Cassette style (standard filter) Long-life filter High efficiency Hi-X heat exchanger coils that provide even more energy savings. Air suction canvas bellows The unit can be installed, if there is a space of 350 mm above ceiling. (when suction panel is used.) Air suction panel Cassette style (high efficiency filter) High efficiency filter Air suction canvas bellows With duct Min. 350 mm Air suction panel Screening door Drain pump is equipped as standard accessory with 250 mm lift. Access panel High external static pressure allows comprehensive duct layout for various applications. 120 Pa for FXDYQ80MA–145MA 150 Pa for FXDYQ180M 180 Pa for FXDYQ200M 200 Pa for FXDYQ250M Ceiling return Indoor Unit Lineup Long-life filter Long-life filter Access panel Design of indoor units allows installation in limited roof spaces. 250 mm Return air spigots included for ease of installation for FXDYQ80MA-145MA models. High external static pressure allows the use of flexible ducts of various length. Low operation sound level FXSYQ-M Sound level (H/L) 20/25/32 40 41/33.5 41/34.5 (230 V)(dB(A)) 50 63 80/100 125 43/37 45/38.5 48/43 49/41.5 The values of operation sound level are based on Australian Standard 1217.6-1985. Measurement is based on bottom-return air entry. 29 Two external static pressure settings for added flexibility. Quiet yet powerful supply air fan. High strength galvanised steel casing. 30 Indoor Unit Lineup Ceiling Suspended Type Ceiling Mounted Duct Type FXMQ20P/FXMQ25P/FXMQ32P FXMQ40P/FXMQ50P/FXMQ63P FXMQ80P/FXMQ100P/FXMQ125P FXMQ140P FXHQ32MA/FXHQ63MA FXHQ100MA Slim body with quiet and wide airflow Middle and high static pressure allows for flexible duct design Adoption of QUIET STREAM FAN Uses the quiet stream fan and many more advanced technologies. A DC fan motor increases the external static pressure capacity range to include middle to high static pressures, increasing design flexibility. Sound absorption member 30 Pa–100 Pa for FXMQ20P-32P 30 Pa–160 Pa for FXMQ40P 50 Pa–200 Pa for FXMQ50P-125P 50 Pa–140 Pa for FXMQ140P Drain pump is equipped as standard accessory with 700 mm lift. Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level (dB(A)) 32 40 50 63 80/100 125 140 Sound level 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 46/45/43 (HH/H/L) Energy-efficient The adopted DC fan motor is much more efficient than the conventional AC motor, yielding an approximate 20% decrease in energy consumption (FXMQ125P). FXMQ200MA/FXMQ250MA Quiet stream fan Straightening vane Low operation sound level 700 mm Ceiling FXMQ-P 20/25 Turbulent flow is produced Improved ease of installation Airflow rate can be controlled using a remote controller during test operation. With the conventional model, the airflow rate was controlled from the PC board. It is automatically adjusted to the range between approximately ±10% of the rated HH tap airflow for FXMQ20P–125P. Housing the drain pump inside the unit reduces the space required for installation. Without drain pump 32 63 100 Sound level (H/L) 36/31 39/34 45/37 Installation is easy Drain pump kit (option) can be easily incorporated. 600 mm Wide air discharge openings produce a spreading 100° airflow. 470 mm Simplified Static Pressure Control External static pressure can be easily adjusted using a change-over switch inside the electrical box to meet the resistance in the duct system. 31 25 mm Indoor unit 222 mm Bristle-free Flap minimises contamination and makes cleaning simpler. Non-dew Flap Easy-to-clean flat design Maintenance is easier because everything can be performed from below the unit. 0–250 470 mm Maintenance is easy Non-dew Flap with no implanted bristles Drain pump kit (built inside main unit) With drain pump mm (dB(A)) FXHQ-MA Improved ease of maintenance The drain pan can be detached for easy cleaning. An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours. Built-in Drain Pump (Option) Indoor Unit Lineup All models are only 300 mm in height, an improvement over the 390 mm height of conventional models. The weight of the FXMQ40P has been reduced from 44 kg to 28 kg. 100° A long-life filter (maintenance free up to one year*) is equipped as standard accessory. * 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3 Indoor unit 32 Indoor Unit Lineup Floor Standing Type Wall Mounted Type FXAQ20P/FXAQ25P FXLQ20MA/FXLQ25MA FXAQ50P/FXAQ63P FXLQ50MA/FXLQ63MA FXLQ32MA/FXLQ40MA FXAQ32P/FXAQ40P Stylish flat panel design harmonised with your interior décor Stylish flat panel design creates a graceful harmony that enhances any interior space. Flat panel can be cleaned with only the single pass of a cloth across their smooth surface. Flat panel can also be easily removed and washed for more thorough cleaning. The adoption of a fibre-less discharge grille featuring an original design to prevent condensation also helps prevent staining and makes cleaning easier. A long-life filter (maintenance free up to one year*) is equipped as standard accessory. (dB(A)) FXAQ-P 20 25 32 40 50 63 Sound level (H/L) 35/31 36/31 38/31 39/34 42/37 47/41 Floor Standing types can be hung on the wall for easier cleaning. Running the piping from the back allows the unit to be hung on walls. Cleaning under the unit, where dust tends to accumulate, is considerably easier. Wall hanging * 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3 Floor installation Concealed Floor Standing Type Drain pan and air filter can be kept clean by mould-proof polystyrene. FXNQ20MA/FXNQ25MA Vertical auto-swing realises efficiency of air distribution. The louvre closes automatically when the unit stops. 5 steps of discharge angle can be set by remote controller. Discharge angle is automatically set at the same angle as the previous operation when restarting. (Initial setting: 10° for cooling and 70° for heating) Flexible installation Drain pipe can be fitted to from either left or right sides. FXNQ32MA/FXNQ40MA FXNQ50MA/FXNQ63MA Drain pump kit is available as optional accessory, which lifts the drain 1,000 mm from the bottom of the unit. Height of drain-up Designed to be concealed in the perimeter skirting-wall 1,000 mm Drain pump kit The unit is concealed in skirting-wall of perimeter, that enables to create high class interior design. Indoor unit The connecting port faces downward, greatly facilitating on-site piping work. A long-life filter (maintenance free up to one year*) is equipped as standard accessory. * 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3 33 Indoor Unit Lineup Low operation sound level Suitable for perimeter zone air conditioning Connecting port Refrigerant piping * Applies also to Floor Standing type (FXLQ-MA). 34 Indoor Unit Specifications Indoor Units Ceiling Mounted Cassette (Round Flow with Sensing) Type kcal/h Cooling capacity Btu/h kW kcal/h Heating capacity Cooling Power consumption Heating Casing Sound power (H/M/L) Dimensions (H×W×D) 12,300 2.8 2,800 Liquid (Flare) Gas (Flare) 3,900 4,800 6,100 7,700 9,600 12,000 15,400 19,100 24,200 30,700 38,200 47,800 4,300 Dimensions(H×W×D) Weight 8,600 10,800 13,800 12.5 16.0 13,600 17,100 21,500 27,300 34,100 3.2 4.0 5.0 6.3 8.0 10.0 0.031 0.041 0.080 0.095 0.194 0.219 0.027 0.037 0.075 0.090 0.180 0.199 kW kW dB(A) dB(A) mm Galvanised steel plate 208/191/166 241/216/183 365/291/224 391/308/224 391/324/249 549/433/316 574/458/349 14.5/13.0/11.0 22.0/17.5/13.5 23.5/18.5/13.5 23.5/19.5/15.0 33.0/26.0/19.0 34.5/27.5/21.0 47/45.5/44 19 mm 12.7 Panel (Option) Power consumption Casing Cooling Heating Airflow rate (HH/H/L) Sound level (HH/H/L) Sound power (HH/H/L) Dimensions (H×W×D) Machine weight Piping connections Panel (Option) 3,900 4,800 6,100 7,700 9,600 12,000 Btu/h 9,600 12,300 15,400 19,100 2.8 3.6 4.5 5.6 24,200 30,700 38,200 47,800 kW 7.1 9.0 11.2 14.0 3,400 4,300 5,400 17,100 21,500 kW 3.2 4.0 Gas (Flare) Weight 54,600 42,700 6.3 8.0 12.5 16.0 0.052 0.066 0.093 0.187 0.209 kW 0.027 0.034 0.038 0.053 0.075 0.174 0.200 /s 216/191/166 250/216/183 266/225/183 316/275/225 350/300/250 533/433/333 550/466/375 dB(A) 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 48/46.5/45 49/47/45 50/47.5/45 52/49/46 53/51.5/49 60/54.5/50 61/56/52 m3/min dB(A) 13/11.5/10 mm 10.0 Galvanised steel plate 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 mm 19.5 246×840×840 32/26/20 33/28/22.5 288×840×840 22 6.4 25 9.5 12.7 15.9 VP25 (External Dia, 32/Internal Dia, 25) BYCP125K-W1 Model Dimensions(H×W×D) 13,800 10,800 5.0 Drain Colour 34,100 0.047 kg Liquid (Flare) 8,600 6,900 27,300 0.033 kW Fresh white mm 50X950X950 kg 5.5 Note: Specifications are based on the following conditions; •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) •Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 35 8,500 10,900 2.5 3.2 0.073 3.6 3,400 13,600 4.0 0.076 4,800 3,900 15,400 4.5 17,100 5.0 21,500 6.3 0.115 0.089 183/133 233/166 240 V dB(A) 32/26 240 V dB(A) 49 34/28 37/29 42/35 0.064 Galvanised steel plate 9/7 9.5/7.5 51 mm Dimensions(H×W×D) 11/8 54 kg 18 mm 12.7 59 6.4 VP20 (External Dia, 26/Internal Dia, 20) BYFQ60B8W1 White (6.5Y9.5/0.5) mm 55×700×700 2.7 kg MODEL 1-phase, 220-240 V/220-230 V, 50/60 Hz Btu/h kW kcal/h Btu/h Heating capacity kW 6,900 9,600 27,300 38,200 8.0 11.2 7,700 10,800 30,700 42,700 9.0 Cooling kW Heating 0.090 kW 0.073 Casing FXUQ100AVEB FXUQ71AVEB kcal/h Cooling capacity 12.5 0.200 0.179 Fresh white /s 375/325/267 517/433/350 m3/min 22.5/19.5/16 31/26/21 Sound level (H/M/L) dB(A) 47/44/40 Sound power (H/M/L) dB(A) 40/38/36 Dimensions (H×W×D) mm Airflow rate (H/M/L) Machine weight kg Liquid (Flare) Piping Gas (Flare) connections Drain 14/10 286×575×575 Colour Power consumption 5.6 158/125 Power supply This model is not compatible both Heat Pump 30 class and Heat Recovery systems. 19,100 5,400 4,300 4-way Flow Ceiling Suspended Type 1-phase, 220-240 V/220 V, 50/60 Hz 3,100 13,600 2.8 2,800 3,100 12,300 150/116 /s Weight 2,400 2,800 2.2 2,200 Model 5.5 10,900 9,600 0.107 Piping Gas (Flare) connections Drain 50×950×950 Btu/h 7,500 FXZQ50MVE 0.080 Dimensions (H×W×D) Fresh white FXZQ40MVE 0.068 m3/min Sound power (H) FXZQ32MVE 1-phase, 220-240 V/220 V, 50/60 Hz Liquid (Flare) kcal/h kcal/h kW Machine weight FXFQ25PVE FXFQ32PVE FXFQ40PVE FXFQ50PVE FXFQ63PVE FXFQ80PVE FXFQ100PVE FXFQ125PVE Power supply Heating Sound level (H/L) BYCQ125B-W1 kg kW Airflow rate (H/L) 15.9 mm Cooling Casing I.D. 25×O.D. 32(VP25) MODEL Heating capacity Power consumption 9.5 Ceiling Mounted Cassette (Round Flow) Type Cooling capacity kW 26 23 2,400 Btu/h Heating capacity 288×840×840 6.4 1,900 Btu/h kW 48/46/44 53/49/45 55/50/45 55/52/48 60/54/48 61/56/51 246×840×840 FXZQ25MVE kcal/h 31/29/27 36/32/28 38/33/28 38/35/31 44/38/32 45/40/35 30/28.5/27 FXZQ20MVE kcal/h Cooling capacity 54,600 42,700 12.5/11.5/10.0 Model Colour 6,900 MODEL Power supply 14.0 11.2 9.0 7.1 5,400 10,900 Drain Panel (Option) 5.6 4.5 3.6 3,400 kg Machine weight Piping connections 3,100 9,600 kW m3/min Sound level (H/M/L) 2,400 Btu/h /s Airflow rate (H/M/L) 1-phase, 220 -240 V/220-230 V, 50/60 Hz Indoor Unit Lineup FXFQ25SVM FXFQ32SVM FXFQ40SVM FXFQ50SVM FXFQ63SVM FXFQ80SVM FXFQ100SVM FXFQ125SVM MODEL Power supply Ceiling Mounted Cassette (Compact Multi Flow) Type 58/56/54 65/62/58 198×950×950 26 27 9.5 mm 15.9 VP20 (External Dia, 26/Internal Dia, 20) • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 36 Indoor Unit Specifications Indoor Units FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE MODEL 1-phase, 220-240 V/220 V, 50/60 Hz Power supply kcal/h 1,900 2,400 3,100 3,900 4,800 6,100 7,700 12,000 Btu/h 7,500 9,600 12,300 15,400 19,100 24,200 30,700 47,800 kcal/h 2,200 2,800 3,400 4,300 5,400 6,900 8,600 13,800 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 34,100 54,600 kW Cooling 2.5 3.2 4.0 5.0 6.3 8.0 10.0 16.0 kW Heating 0.077 0.092 0.130 0.106 0.209 0.256 kW 0.044 0.059 0.097 0.126 0.176 0.223 Cooling capacity kW Heating capacity Power consumption Slim Ceiling Mounted Duct Type (700 mm width type) 2.2 2.8 3.6 5.6 7.1 9.0 14.0 Galvanised steel plate Casing /s Airflow rate (H/L) m3/min Sound level (H/L) 240 V Dimensions (H×W×D) Machine weight dB(A) mm 116/83 150/108 200/150 275/216 433/350 550/416 7/5 9/6.5 12/9 16.5/13 26/21 33/25 34/29 36/30 37/32 39/34 41/36 46/40 305×990×600 305×775×600 26.0 kg 31.0 Liquid (Flare) Piping Gas (Flare) connections Drain mm Colour Weight 32.0 35.0 mm 53×1,030×680 kg 8.0 305×1,665×600 47.0 48.0 6.4 9.5 12.7 15.9 BYBC32G-W1 Dimensions(H×W×D) 305×1,175×600 VP25 (External Dia, 32/Internal Dia, 25) Model Panel (Option) 4.5 53×1,245×680 53×1,430×680 53×1,920×680 8.5 9.5 12.0 Ceiling Mounted Cassette Corner Type kcal/h Cooling capacity Btu/h kW kcal/h Heating capacity Power consumption Casing Btu/h Cooling Heating Airflow rate (H/L) Sound level (H/L) 240 V kW kW mm kg Dimensions(H×W×D) Weight 3,900 mm kg 6,100 12,300 15,400 24,200 2,800 3,400 4,300 6,900 2.8 3.6 10,900 3.2 13,600 4.0 0.066 11/9 40/35 4.5 7.1 17,100 27,300 0.076 0.105 5.0 0.056 Galvanised steel plate 216/166 215X1,110X710 13/10 42/36 31 6.4 12.7 VP25 (External Dia, 32/Internal Dia, 25) Model Colour 3,100 FXKQ63MAVE 9,600 183/150 Liquid (Flare) Piping connections Gas (Flare) Drain Panel (Option) 2,400 /s mm FXKQ40MAVE 1-phase, 220 -240 V/220 V, 50/60 Hz 0.046 Dimensions (H×W×D) Machine weight FXKQ32MAVE kW m3/min dB(A) BYK45FJW1 White (10Y9/0.5) 8.0 0.085 300/250 18/15 44/39 215X1,310X710 34 9.5 15.9 BYK71FJW1 70X1,240X800 70X1,440X800 8.5 9.5 Note: Specifications are based on the following conditions; •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. •Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) •Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. (FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 37 FXDQ20PBVE Power consumption 1 Cooling Heating Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) 1 3 kcal/h 1,900 Btu/h 7,500 FXDQ25PBVE 1-phase, 220-240 V/220 V, 50/60 Hz 2,400 kW 2.2 2.8 3.6 2,200 2,800 3,400 Btu/h 8,500 10,900 13,600 kW 2.5 3.2 kW 0.086 kW 0.067 4.0 0.089 0.070 Galvanised steel plate /s 133/120/106 m3/min 8.0/7.2/6.4 Pa 30-10 dB(A) 2 33/31/29 51 mm 200×700×620 kg 23.0 6.4 Liquid (Flare) Piping Gas (Flare) connections Drain 3,100 12,300 9,600 dB(A) Sound power (HH) FXDQ32PBVE kcal/h mm 12.7 VP20 (External Dia, 26/Internal Dia, 20) Slim Ceiling Mounted Duct Type (900/1,100 mm width type) MODEL FXKQ25MAVE MODEL Power supply Heating capacity Machine weight BYBC125G-W1 White (10Y9/0.5) Cooling capacity Dimensions (H×W×D) BYBC63G-W1 BYBC50G-W1 MODEL Power supply FXDQ40NBVE Power supply Cooling capacity Heating capacity Power consumption 1 Cooling Heating Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) 1 3 Sound power (HH) Dimensions (H×W×D) Machine weight Liquid (Flare) Piping Gas (Flare) connections Drain FXDQ50NBVE 1-phase, 220-240 V/220 V, 50/60 Hz FXDQ63NBVE kcal/h 3,900 4,800 6,100 Btu/h 15,400 19,100 24,200 kW 4.5 5.6 7.1 kcal/h 4,300 5,400 6,900 Btu/h 17,100 21,500 27,300 kW 5.0 6.3 8.0 kW 0.160 0.165 0.181 kW 0.147 0.152 0.168 /s 175/158/141 m3/min Galvanised steel plate 208/183/166 10.5/9.5/8.5 12.5/11.0/10.0 34/32/30 35/33/31 52 53 Pa dB(A) dB(A) mm kg mm 27.0 44-15 200×900×620 6.4 Indoor Unit Lineup Ceiling Mounted Cassette (Double Flow) Type 275/241/216 16.5/14.5/13.0 2 28.0 12.7 36/34/32 54 200×1,100×620 31.0 9.5 15.9 VP20 (External Dia, 26/Internal Dia, 20) • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 1: Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa. 2: External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is 10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.) 3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). 38 Indoor Unit Specifications Indoor Units Ceiling Mounted Duct Type MODEL FXSYQ20MVE FXSYQ25MVE FXSYQ32MVE FXSYQ40MVE FXSYQ50MVE FXSYQ63MVE FXSYQ80MVE FXSYQ100MVE FXSYQ125MVE Power supply Cooling capacity 1-phase, 220-240 V, 50 Hz kcal/h 1,900 2,400 3,100 Btu/h 7,500 9,600 12,300 kW kcal/h Btu/h Heating capacity kW Power consumption Cooling kW Heating kW Casing /s Airflow rate (H/L) m3/min Pa External static pressure 2.2 2.8 3.6 2,200 2,800 3,400 10,900 13,600 3.2 4.0 8,500 2.5 0.089 0.096 0.089 0.096 Piping Gas (Flare) connections Drain Weight 24,200 30,700 38,000 47,800 7.1 9.0 11.2 14.0 5,400 6,900 8,600 10,800 13,800 34,100 42,700 54,600 10.0 12.5 16.0 0.304 0.309 0.366 0.304 0.309 0.366 5.6 4.5 4,300 21,500 17,100 27,300 6.3 5.0 8.0 0.145 0.106 0.178 0.145 0.106 0.178 350/235 450/355 466/370 21/14.1 27/21.3 28/22.2 38/27.42 98-65-33 1 191/143 1 88-57-27 96-65-57 1 86-58-43 41/33.5 41/34.5 43/37 58/50.5 58/51.5 60/54 30 34 35 300X550X800 300X700X800 1 115-84-52 1 140-122-61 1 138-118-53 1 98-58 2 48/43 49/41.5 62/55.5 65.5/60 66/59 300X1,000X800 300X1,400X800 44 57 6.4 9.5 12.7 15.9 BYBS45DJW1 633/457 45/38.5 VP25 (External Dia, 32/Internal Dia, 25) BYBS32DJW1 Dimensions(H×W×D) 19,100 250/190 mm Colour 12,000 158/112 Model Panel (Option) 9,600 9.5/6.72 11.5/8.58 15/11.4 kg Liquid (Flare) 7,700 9/6.72 mm Machine weight 6,100 150/112 Sound power (H/L) 230 V dB(A) Dimensions (H×W×D) 15,400 4,800 Galvanised steel plate 230 V dB(A) Sound level (H/L) 3,900 BYBS71DJW1 White (10Y9/0.5) 55X650X500 55X800X500 55X1,100X500 55X1,500X500 3.0 3.5 4.5 6.5 Cooling capacity kcal/h 7,600 9,600 12,000 13,800 17,200 19,300 24,100 Btu/h 30,000 38,200 47,400 54,600 68,200 76,400 95,500 kcal/h Btu/h Heating capacity kW Power consumption Cooling kW Heating kW Casing /s Airflow rate (H) m3/min External static pressure (H) Sound level (H) Machine weight Liquid (Flare) Piping Gas (Flare) connections Drain 8,480 33,800 11.2 mm kg mm 13.9 10,800 13,800 42,700 54,600 12.5 16.0 0.700 0.780 0.415 0.700 0.780 510 778 30.6 46.7 45 46 50 60 9.9 0.415 120 360X1168X869 16.0 15,800 62,800 18.4 0.880 20.0 22.4 19,300 21,500 76,400 85,300 22.4 25.0 0.980 0.880 0.980 852 957 51.1 57.4 1.020 3 360X1478X899 65 15.9 9.5 VP25 (External Dia, 32/Internal Dia, 25) 107,500 31.5 1.200 1,180 1,200 1,400 70.8 72.0 84.0 180 200 51 66 27,100 1.200 150 48 28.0 1.020 Galvanised steel plate Pa 240 V dB(A) Dimensions (H×W×D) 8.8 500X1210X910 77 79 19.1 500X1410X910 98 22.2 BSP 3/4 inch internal thread Note: Specifications are based on the following conditions; •Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. •Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CWB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) •Sound level: (FXSYQ) Anechoic chamber conversion value, based on Australian Standard 1217.6-1985. Measurement is based on bottom-return air entry. (FXDYQ) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. •For FXDYQ models, an air filter is not a standard accessory. A suitable locally obtained filter must be installed in the return air duct. 1: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard-Low static pressure". 2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "High static pressure-Standard". 3: External static pressure is changeable to change over the connectors inside electrical box (High static pressure-Standard static pressure). The data above is for high static pressure setting. 39 1 1,900 2,400 3,100 3,900 4,800 Btu/h 7,500 9,600 12,300 15,400 19,100 kW 2.2 2.8 3.6 4.5 5.6 kcal/h 2,200 2,800 3,400 4,300 5,400 Btu/h 8,500 10,900 13,600 17,100 21,500 kW 2.5 3.2 4.0 5.0 6.3 0.060 0.151 0.128 0.073 0.182 0.203 158/133/116 267/216/183 300/275/250 9.5/8/7 16/13/11 Cooling kW 0.056 Heating kW 0.069 Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) Sound power (H) Dimensions (H×W×D) Power supply FXDYQ80MAV1 FXDYQ100MAV1 FXDYQ125MAV1 FXDYQ145MAV1 FXDYQ180MV1 FXDYQ200MV1 FXDYQ250MV1 kW Power consumption kcal/h /s 9/7.5/6.5 Pa 2 30-100 (50) dB(A) dB(A) 30-160 (100) 33/31/29 34/32/30 51 52 mm 18/16.5/15 2 39/37/35 300X550X700 25 kg 50-200 (100) 2 41/39/37 57 59 300X700X700 300X1,000X700 28 36 6.4 mm 12.7 VP25 (External Dia, 32/Internal Dia, 25) FXMQ63PVE FXMQ80PVE FXMQ100PVE FXMQ125PVE FXMQ140PVE 1-phase, 220-240 V/220 V, 50/60 Hz kcal/h Cooling capacity Btu/h kW Heating capacity Power consumption Galvanised steel plate 150/125/108 m3/min MODEL Ceiling Concealed (Duct) Type 1-phase, 220 -240 V, 50 Hz Heating capacity Piping connections Gas (Flare) Drain kg Power supply Cooling capacity Liquid (Flare) mm MODEL 1-phase, 220-240 V/220 V, 50/60 Hz Machine weight BYBS125DJW1 FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE MODEL Power supply 1 Cooling Heating 6,100 7,700 9,600 12,000 13,800 24,200 30,700 38,200 47,800 54,600 7.1 9.0 11.2 14.0 16.0 kcal/h 6,900 8,600 10,800 13,800 15,500 Btu/h 27,300 34,100 42,700 54,600 61,400 kW 8.0 10.0 12.5 16.0 18.0 kW 0.138 0.185 0.215 0.284 0.405 kW 0.218 0.286 0.364 0.449 0.449 766/649/533 Indoor Unit Lineup Ceiling Mounted Built-in Type Galvanised steel plate Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) Sound power (H) Dimensions (H×W×D) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain /s m3/min Pa dB(A) dB(A) mm kg mm 325/292/267 417/375/333 533/450/383 650/550/466 19.5/17.5/16 25/22.5/20 32/27/23 39/33/28 50-200 (100) 2 46/39/32 50-140 (100) 42/40/38 43/41/39 44/42/40 46/45/43 60 61 62 64 2 300X1,400X700 300X1,000X700 36 46 47 9.5 15.9 VP25 (External Dia, 32/Internal Dia, 25) Note: Specifications are based on the following conditions; • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. •Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) •Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 1: Power consumption values are based on conditions of rated external static pressure. 2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P. 40 Indoor Unit Specifications Indoor Units Ceiling Mounted Duct Type Wall Mounted Type FXMQ200MAVE MODEL 19,300 kW Power consumption Casing Cooling Heating Btu/h 85,300 107,500 kW 25.0 kW 1.294 kW 1.294 240 V Dimensions (H×W×D) Machine weight Piping connections Gas (Flare) Drain 1.465 1 1.465 Heating capacity 1 Power consumption 1 Pa 966/833 1,200/1,033 58/50 72/62 132-221 dB(A) 2 191-270 3,100 3,900 4,800 6,100 7,500 9,600 12,300 15,400 19,100 24,200 kcal/h 2,200 2,800 3,400 4,300 5,400 6,900 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 kW 2.5 3.2 4.0 5.0 6.3 8.0 kW 0.019 0.028 0.030 0.020 0.033 0.050 kW 0.029 0.034 0.035 0.020 0.039 0.060 /s m3/min dB(A) Sound level (H/L) 2 Dimensions (H×W×D) Machine weight 470X1,380X1,100 mm 2.2 2.8 Piping connections Gas (Flare) Drain 9.5 19.1 22.2 3.6 4.5 5.6 7.1 White (3.0Y8.5/0.5) 125/75 133/83 142/91 200/150 250/200 316/233 7.5/4.5 8/5 8.5/5.5 12/9 15/12 19/14 35/31 36/31 290×795×238 38/31 39/34 42/37 290×1,050×238 47/41 kg 11.0 Liquid (Flare) 137 mm Heating Airflow rate (H/L) 49/46 mm Cooling Casing Galvanised steel plate kg Liquid (Flare) 31.5 1 2,400 kW 27,100 1-phase, 220-240 V/220 V, 50/60 Hz 1,900 Btu/h 28.0 21,500 m3/min External static pressure Sound level (H/L) 22.4 FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE kcal/h Cooling capacity 95,500 kcal/h /s Airflow rate (H/L) 24,100 76,400 Btu/h Heating capacity MODEL Power supply 1-phase, 220 -240 V/220 V, 50/60 Hz kcal/h Cooling capacity FXMQ250MAVE 14.0 6.4 9.5 12.7 mm 15.9 VP13 (External Dia, 18/Internal Dia, 13) PS1B Floor Standing Type/Concealed Floor Standing Type Ceiling Suspended Type FXHQ32MAVE MODEL Power supply kcal/h Cooling capacity Heating Casing Airflow rate (H/L) 9,600 38,200 3.6 7.1 11.2 kW kW kW /s m3/min Machine weight kg Piping connections Gas (Flare) Drain 6,100 24,200 dB(A) Liquid (Flare) 3,100 12,300 Sound level (H/L) Dimensions (H×W×D) FXHQ100MAVE kW Btu/h Cooling FXHQ63MAVE 1-phase, 220-240 V/220 V, 50/60 Hz Btu/h kcal/h Heating capacity Power consumption mm 3,400 6,900 10,800 13,600 27,300 42,700 4.0 8.0 12.5 0.111 0.115 0.135 0.111 0.115 0.135 200/166 291/233 416/325 12/10 17.5/14 25/19.5 45/37 36/31 39/34 195×960×680 195×1,160×680 24.0 28.0 6.4 mm White (10Y9/0.5) 12.7 195×1,400×680 33.0 9.5 15.9 VP20 (External Dia, 26/Internal Dia, 20) • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. (FXHQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions 1: Power consumption values are based on conditions of rated external static pressure. 2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure". 41 FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE MODEL Power supply FXLQ FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE kcal/h Cooling capacity Btu/h kW Heating capacity FXNQ Power consumption Cooling Heating Casing Sound level (H/L) Dimensions (H×W×D) FXNQ Machine weight FXLQ FXNQ 3,900 4,800 6,100 9,600 12,300 15,400 19,100 24,200 2.2 2.8 3.6 4.5 5.6 7.1 2,800 3,400 4,300 5,400 6,900 Btu/h 8,500 10,900 13,600 17,100 21,500 27,300 kW 2.5 3.2 4.0 5.0 6.3 8.0 kW 0.049 0.090 0.110 kW 0.049 0.090 0.110 dB(A) mm kg Liquid (Flare) Piping connections Gas (Flare) Drain 3,100 7,500 2,200 m3/min FXLQ 2,400 kcal/h /s Airflow rate (H/L) 1-phase, 220-240 V/220 V, 50/60 Hz 1,900 mm Indoor Unit Lineup Power supply FXLQ: Ivory white (5Y7.5/1)/FXNQ: Galvanised steel plate 116/100 133/100 183/141 233/183 266/200 7/6 8/6 11/8.5 14/11 16/12 35/32 38/33 39/34 40/35 600×1,000×222 600×1,140×222 600×1,420×222 610×930×220 610×1,070×220 610×1,350×220 19.0 23.0 27.0 25.0 30.0 36.0 6.4 9.5 12.7 15.9 VP13 (External Dia, 18/Internal Dia, 13) • Cooling: Indoor temp.: 27°CDB, 19°CWB, Outdoor temp.: 35°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Heating: Indoor temp.: 20°CDB, Outdoor temp.: 7°CDB, 6°CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. • Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) • Sound level: (FXAQ-P) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. (FXLQ-MA, FXNQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions. 42 Indoor Unit Option List Indoor Units No. 1 2 3 4 5 6 7 Type FXFQ25S FXFQ32S FXFQ40S FXFQ50S FXFQ63S FXFQ80S FXFQ100S FXFQ125S Item Decoration panel Sealing material of air discharge outlet Panel spacer Filter related High efficiency filter unit 65% High efficiency filter unit 90% Replacement high efficiency filter 65% Replacement high efficiency filter 90% Filter chamber Long life replacement filter Ultra long-life filter Replacement ultra long-life filter Fresh air intake kit Chamber type Without T joint-pipe and fan With T joint-pipe without fan Direct installation type Branch duct chamber Insulation kit for high humidity Slim Ceiling Mounted Duct Type (700 mm width type) No. 1 BYCQ125B-W1 KDBHQ55B140 KDBP55H160FA KAFP556B80 KAFP557B80 KAFP552B80 KAFP553B80 KDDFP55B160 KAFP551K160 KAFP55B160 KAFP55H160H KDDQ55B140 KDDP55B160K KDDP55X160 KDJP55B80 KDTP55K80 KAFP556B160 KAFP557B160 KAFP552B160 KAFP553B160 1 2 3 4 5 6 7 8 Decoration panel Sealing material of air discharge outlet Panel spacer Filter related High efficiency filter unit 65% High efficiency filter unit 90% Replacement high efficiency filter 65% Replacement high efficiency filter 90% Filter chamber Long life replacement filter Ultra long-life filter Replacement ultra long-life filter Fresh air intake kit Chamber type Without T joint-pipe and fan With T joint-pipe without fan Direct installation type Branch duct chamber Chamber connection kit Insulation kit for high humidity No. 1 No. KDJP55B160 KDTP55K160 BYCP125K-W1 KDBH55K160F KDBP55H160FA KAFP556B80 KAFP557B80 KAFP552B80 KAFP553B80 KDDFP55B160 KAFP551K160 KAFP55B160 KAFP55H160H KDDP55B160 KDDP55B160K KDDP55X160 KDJP55B80 KKSJ55KA160 KDTP55K80 KAFP556B160 KAFP557B160 KAFP552B160 KAFP553B160 KDTP55K160 Ceiling Mounted Cassette (Compact Multi Flow) Type No. 1 2 3 4 5 Type Item 4-way Flow Ceiling Suspended Type No. 1 2 3 FXZQ20M FXZQ25M Decoration panel Sealing material of air discharge outlet Panel spacer Replacement long-life filter Fresh air intake kit Direct installation type Item FXZQ32M FXZQ40M FXZQ50M BYFQ60B8W1 KDBH44BA60 KDBQ44BA60A KAFQ441BA60 KDDQ44XA60 Type FXUQ71A 1 2 Decoration panel Filter related High efficiency filter 65% 1 High efficiency filter 90% 1 Filter chamber bottom suction Long life replacement filter Note: 1 Filter chamber is required if installing high efficiency filter. FXCQ20M FXCQ25M 43 Item 1 Panel related 2 Air inlet and air discharge outlet related Type Decoration panel Panel spacer Long life replacement filter Air discharge grille Air discharge blind panel Flexible duct (with shutter) 3 Air inlet related BYBC32G-W1 KAFJ532G36 KAFJ533G36 KDDFJ53G36 KAFJ531G36 FXCQ50M BYBC50G-W1 KAFJ532G56 KAFJ533G56 KDDFJ53G56 KAFJ531G56 FXCQ63M No. 1 FXKQ32MA BYK45FJW1 KPBJ52F56W KAFJ521F56 K-HV7AW KDBJ52F56W KFDJ52FA56 Decoration panel Access panel High efficiency filter 65% 1 High efficiency filter 90% 1 Long life replacement filter Filter chamber for bottom suction Air suction canvas Screening door BYBC63G-W1 KAFJ532G80 KAFJ533G80 KDDFJ53G80 KAFJ531G80 FXCQ125M BYBC125G-W1 KAFJ532G160 KAFJ533G160 KDDFJ53G160 KAFJ531G160 FXKQ40MA FXDQ63NB FXSYQ20M FXSYQ25M FXSYQ32M BYBS32DJW1 KTBJ25K36W KAFJ252L36 KAFJ253L36 KAFJ251K36 KAJ25L36D KSA-25K36 KBBJ25K36 KDT25N63 FXSYQ40M FXSYQ50M FXSYQ63M BYBS45DJW1 KTB25KA56W KAF252LA56 KAF253LA56 KAFJ251K56 KAJ25LA56D KSA-25KA56 KBBJ25KA56 BYBS71DJW1 KTB25KA80W KAF252LA80 KAF253LA80 KAFJ251K80 KAJ25LA80D KSA-25KA80 KBBJ25KA80 FXSYQ80M FXSYQ100M FXSYQ125M BYBS125DJW1 KTB25KA160W KAF252LA160 KAF253LA160 KAFJ251K160 KAJ25LA160D KSA-25KA160 KBBJ25KA160 Type FXDYQ80MA FXDYQ100MA FXDYQ125MA FXDYQ145MA FXDYQ180M FXDYQ200M FXDYQ250M Item Run/fault status PCB KRP1B5X Ceiling Mounted Duct Type Type Item 1 2 Drain pump kit High efficiency filter 3 4 5 6 Filter chamber Long life replacement filter Long life filter chamber kit Service panel 7 Air discharge adaptor 65% 90% White Fresh white Brown Item No. 1 Item Drain pump kit Item Long life replacement filter Concealed Floor Standing Type No. Type Drain pump kit Replacement long-life filter (Resin net) L-type piping kit (for upward direction) Floor Standing Type 1 FXKQ25MA Type Ceiling Concealed (Duct) Type No. FXCQ80M FXDQ50NB 1 If installing a high efficiency filter in the Ceiling Mounted Built-in type, a filter chamber for bottom suction is required. 1 FXCQ40M FXDQ32PB KDT25N50 Wall Mounted Type Ceiling Mounted Cassette Corner Type No. Filter related 1 2 3 KDBHP49B140 KDBTP49B140 KAFP551K160 Type Item 2 No. Ceiling Mounted Cassette (Double Flow) Type No. Item Panel related Note: FXDQ40NB Insulation kit for high humidity Ceiling Suspended Type FXUQ100A Sealing material of air discharge outlet Decoration panel for air discharge Replacement long-life filter Type Item 1 No. KDJP55B160 FXDQ25PB KDT25N32 Ceiling Mounted Built-in Type Type FXFQ25P FXFQ32P FXFQ40P FXFQ50P FXFQ63P FXFQ80P FXFQ100P FXFQ125P Item FXDQ20PB Insulation kit for high humidity Slim Ceiling Mounted Duct Type (900/1,100 mm width type) Ceiling Mounted Cassette (Round Flow) Type No. Type Item Item Long life replacement filter FXMQ20P FXMQ25P FXMQ32P FXMQ40P KAF372AA36 KAF373AA36 KDDF37AA36 KAF371AA36 KAF375AA36 KTBJ25K36W KTBJ25K36F KTBJ25K36T KDAJ25K36A KAF372AA56 KAF373AA56 KDDF37AA56 KAF371AA56 KAF375AA56 KTB25KA56W KTBJ25K56F KTBJ25K56T KDAJ25K56A FXHQ32MA KDU50N60VE KAF501DA56 KHFP5MA63 Type FXAQ20P Type FXLQ20MA — FXMQ50P FXMQ63P FXMQ80P KAF372AA80 KAF373AA80 KDDF37AA80 KAF371AA80 KAF375AA80 KTB25KA80W KTBJ25K80F KTBJ25K80T KDAJ25K71A FXHQ63MA KAF501DA80 FXMQ100P FXMQ125P FXMQ140P FXMQ200MA FXMQ250MA KAF372AA160 KAF373AA160 KDDF37AA160 KAF371AA160 KAF375AA160 KTB25KA160W KTBJ25K160F KTBJ25K160T KDAJ25K140A KDU50N125VE KHFP5MA160 KDU30L250VE KAFJ372L280 KAFJ373L280 KDJ3705L280 KAFJ371L280 — FXHQ100MA KAF501DA112 FXAQ25P FXAQ32P FXAQ40P FXAQ50P FXAQ63P FXLQ25MA FXLQ32MA FXLQ40MA FXLQ50MA FXLQ63MA KAFJ361K28 K-KDU572EVE KAFJ361K45 Indoor Unit Lineup Ceiling Mounted Cassette (Round Flow With Sensing) Type KAFJ361K71 Type FXNQ20MA FXNQ25MA FXNQ32MA FXNQ40MA FXNQ50MA FXNQ63MA KAFJ361K28 KAFJ361K45 KAFJ361K71 FXKQ63MA BYK71FJW1 KPBJ52F80W KAFJ521F80 K-HV9AW KDBJ52F80W KFDJ52FA80 44 Control Systems Individual Control Systems for Indoor Units Convenience “Nav Ease” (Wired remote controller) (Option) This simple, contemporary remote controller with fresh white colour matches your interior design. The clear, backlight display with large easy-to-read text makes navigation easy and provides one-touch control over your in-home comfort. Clear display Dot matrix display A combination of fine dots enables various icons.Large text display is easy to see. Setback (default:OFF) Maintains the room temperature in a specific range during unoccupied period by temporarily starting air conditioner that was turned OFF. Ex) Setback temperature Cooling : 35ºC Recovery differential Cooling : -2ºC When the room temperature goes above 35ºC, the air conditioner starts operating in Cooling automatically. When room temperature reaches 33ºC, the air conditioner returns OFF. Setback temperature Recovery differential Cooling 33 37ºC -2 -8ºC Heating 10 15ºC +2 +8ºC Weekly schedule Backlight display Backlight display helps operating in dark rooms. 5 actions per day can be scheduled for each day of the week. The holiday function will disable schedule timer for the days that have been set as holiday. 3 independent schedules can be set. (e.g. summer, winter, mid-season) College classroom sample (a summer Monday case) BRC1E62 1) 8:30 ON 2) 10:00 The first period starts and the air conditioner starts the cooling operation. ON Simple operation OFF 3) 13:00 In the second period, the classroom is unoccupied and the air conditioner stops. ON 4) 15:00 When the third period starts, operation starts again. OFF ON OFF After the third period, the classroom becomes vacant again and the air conditioner stops. OFF Large buttons and arrow keys Large buttons and arrow keys enable easy operation. Basic setting such as fan speed and temperature can be intuitively operated. For other settings just select the function from the menu list. Guide on display The display gives an explanation of each setting for easy operation. Multingual display Energy saving 11 display languages are available. (English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish and Polish) Until now only the temperature for one point could be set, but now the new remote controller (BRC1E62) allows the setting of both Cooling and Heating, and with the fan operation, mid-range temperatures are comfortable and operation is more energy efficient. 20ºC 26ºC Fan operation operation Saves energy by limiting the min. and max. set temperature. Avoids excessive cooling or heating. This function is convenient when the remote controller is installed at a place where any number of people may operate it. Individual airflow direction (*1) Cooling / Heating Heating Setpoint range set Comfort 2 setpoints Airflow direction of each of the four air outlets can be controlled individually. (Positions 0 to 4, Swing, and No individual setting are selectable.) Cooling operation 1 2 3 4 2 Setpoint auto reset Even if the set temperature is changed, it returns to the preset temperature after a preset period of time. Period selectable from 30 min / 60 min / 90 min / 120 min. Outlet mark 1 3 Control Systems Auto operation mode Restaurant sample Restaurant opened Temperature is set to 27ºC 27 °C Full tables at lunchtime Then is lowered to 24ºC for crowded room 24 °C After 30 minutes* Automatically returns to preset temperature (27ºC) Returns to 27 °C Off timer Turns off the air conditioner after a preset period of time. Period can be preset from 30 to 180 minutes in 10-minute increments. 03 45 4 automatically Auto airflow rate (*1) *Setting possible for after 30, 60, 90, and 120 minutes. Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature. *1 Only available for 4-Way Flow Ceiling Suspended type FXUQ-A series and Ceiling Mounted Cassette (Round Flow with Sensing) type FXFQ-S series. 04 46 Control Systems Individual Control Systems for Indoor Units Wireless remote controller (Option) The wired remote controller supports a wide range of control functions Control of Cool/Heat changeover The same operation modes and settings as with wired remote controllers are possible. In all the series of GHP, Cool/Heat changeover in the same refrigerant circuit can be changed by the remote controller of the indoor unit. Outdoor unit * Individual airflow direction, auto airflow rate and sensing sensor control can be set only via wired remote controller BRC1E62. Cannot be set via other remote controllers. A compact signal receiver unit (separate type) to be mounted into a wall or ceiling is included. Group control One remote controller can control the operation of max.16 indoor units at the same time. Equipment related to the central control • A signal receiver unit (installed type) for a Ceiling Mounted Cassette (Round Flow, Compact Multi Flow, Double Flow) type, Ceiling Suspended type and Wall Mounted type is mounted into the indoor unit. Signal receiver unit can be installed on the panel Signal receiver unit (Separate type) Remote controller Indoor unit Remote controller * Wireless remote controller and signal receiver unit are sold as a set. * Refer to page 55 for the name of each model. Forced OFF input Remote controller Remote controller Remote controller Heat Reclaim Ventilator Concealed type Remote controller (For hotel use) (BRC3A61) Exposed type (BRC2C51) 1 Signal receiver unit (Installed type) Simplified remote controller (Option) Remote controller Remote controller ex. Ceiling Mounted Cassette (Round Flow) type Wireless remote controller 2 3 The remote controller has centralised its frequently used operation selectors and switches (on/off, operation mode, temperature setting and airflow volume), making itself suitable for use in hotel rooms or conference rooms. The concealed type remote controller smartly fits into a night table or console panel in a hotel room. The exposed type remote controller is fitted with a thermostat sensor. 4 1 Control by two remote controller The indoor unit can be connected by the two remote controller, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely.(The last command has a priority.) Of course, the group control by two remote controller is also possible. 2 Remote control The wiring of remote controller can be extended to max. 500 m and it is possible to install the remote controllers for the different indoor units in one place. FXFQ-S FXFQ-P “Nav Ease” (Wired remote controller) (BRC1E62) Wireless remote controller* (Installed type signal receiver unit) FXZQ FXCQ FXUQ FXKQ FXDQ FXSYQ FXDYQ FXMQ FXHQ FXAQ FXL(N)Q Control Systems Wide variation of remote controllers for indoor units Wireless remote controller* (Separate type signal receiver unit) Simplified remote controller 3 Control for the combined operation The operation of Heat Reclaim Ventilator can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter. 03 47 4 Expansion of system control The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc. (Exposed type) (BRC2C51) Simplified remote controller (Concealed type: for Hotel use) (BRC3A61) *Refer to page 55 for the name of each model. 04 48 Control Systems Centralised Control Systems for Indoor Units •Up to 64 groups of indoor units (128 units) can be centrally controlled. •Optional controllers for centralised control can be combined freely, and system can be designed in accordance with building scale and purpose. •System integration with various air-conditioning peripheral equipment such as Heat Reclaim Ventilator is easy. •Wiring can be run up to a total length of 2 km, and adapts DCS302CA61 Connection of up to 8 units possible Independent and centralised control of Heat Reclaim Ventilator is possible. Address setting of central control can be performed from the remote controller. System without remote control is also available. Max. 16 groups of indoor units can be operated simultaneously/individually. Group control of up to 16 units is possible (group control via automatic address setting) 8 units Schedule timer 1 unit The VRV system can be combined. DCS301BA61 Up to 2 units connectable Central control adaptor kit (DTA107A55). Outdoor-air processing unit can be connected. 7 cores max. Unification adaptor for computerised control (DCS302A52) Interlink Building Management System (host computer monitor panel) also possible Certain indoor units limit the functions of some control systems. For more details, please refer to the Engineering Data. 03 49 Schedule timer (Option) Max. 128 indoor units can be operated as programmed schedule. •Max. 128 indoor units controllable •When used in combination with a central remote controller, a maximum of 8 weekly Interface adaptor for SkyAir series (DTA112BA51) 6 cores Schedule timer (DST301BA61) 1 unit connection possible; 8 weekly schedule control patterns possible Wiring adaptor for other airconditioners (DTA103A51) •Max. 16 groups (128 indoor units) controllable •2 remote controllers can be used to control from 2 different places. •Operating status indication (Normal operation, Alarm) •Centralised control indication •Max. wiring length 1,000 m (Total: 2,000 m) •Compact size casing (Thickness: 16 mm) •Connectable with Central Remote controller, Schedule timer and BMS system DST301BA61 • • • • schedule patterns can be set, while the central controller can be used to select desired zones. Up to 2 ON/OFF pairs can be set per day. Max. 48 hours back up power supply Max. wiring length 1,000 m (Total: 2,000 m) Compact size casing (Thickness: 16 mm) Connectable with Central Remote controller, Unified ON/OFF controller and BMS system Control Systems Forced shut-down input Central remote controller (DCS302CA61) •Max. 64 groups (128 indoor units) controllable •Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers, which can control from 2 different places. •Zone control •Malfunction code display •Max. wiring length 1,000 m (Total: 2,000 m) •Connectable with Unified ON/OFF controller, schedule timer and BMS system •Airflow volume and direction can be controlled individually for indoor units in each group operation. •Ventilation volume and mode can be controlled for Heat Reclaim Ventilator. •Up to 4 ON/OFF pairs can be set per day by connecting a schedule timer. Unified ON/OFF controller (Option) Connectable number of centralised control equipment Unified on/off controller Max. 64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller. easily to large-scale system expansion. Unified on/off controller (DCS301BA61) Central remote 2 units controller Central remote controller (Option) 04 50 Control Systems Advanced Control Systems for Indoor Units Interface for Communication functions in the user-friendly icon-based multilingual controller simplify centralised control of the GHP system. BACnet and LONWORKS Integrated control systems that recognise the trend of open control systems Ethernet Please contact Daikin for compatibility with BMS system BMS DCS601C51 Lift Pump Lighting,etc Fire alarm Security Power supply facility DMS502B51 DMS504B51 (Interface for use in BACnet®) (Interface for use in LONWORKS®) GHP System Local Controller D -NET D -NET Plus Adaptor DCS601A52 (Option) Indoor Unit Number of indoor units expanded from 64 to 128. Features •Colour LCD touch panel icon display •Small manageable size •Simplified engineering •Multi language (English, French, Italian, German, Spanish, Heat Reclaim Ventilator •Compatibility with BMS enhanced by utilising the international communication standards, BACnet® or LONWORKS®. DMS502B51 Interface for use in BACnet® DMS504B51 Interface for use in LONWORKS® •Support for Heat Reclaim Ventilator VAM series •Selectable temperature unit •BTL Certification •PPD data (Optional Di board is required.) •ISO 16484-5 (Does not support IEEE 802.3 protocol for BACnet®) •Up to 40 outdoor units and 256 indoor unit groups on one gateway (optional adaptor) •XIF file for confirming of specifications of the units. •Connectable up to 10 outdoor units and 64 indoor unit groups. Control Systems RS-232C Heat Reclaim Ventilator Dutch, Portuguese, Chinese and Korean) •Yearly schedule •Auto heat/cool change-over •Temperature limitation •Enhanced history function •Built-in modem for connecting to Air Conditioning Network Service System (Option) •Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option) 03 51 04 52 Control Systems Integrated Building Monitoring System DIII-NET Line The high speed transmission of DIII-NET enables more advanced control of the GHP system, providing you with enhanced comfort. BACnet®/Ethernet or LONWORKS® Network Communication Line Contact Signal Line The DIII-NET system provides for: • Close control and monitoring by integrating a wide variety of air-conditioners in the entire building. • Saving the in-building cabling using non-polar, two-wire cables. Easier wiring work with tremendously fewer wiring errors. • Additional setups readily up and running. An extendable cabling up to 2 km in total. • Different control equipment flexibly joined in the system for hierarchical risk diversification. • Daikin's total heat exchangers and other devices under integral control. GHP Controllers for Centralised Control Heat Reclaim Ventilator (DCS601C51) D -NET (High Speed Multiple Transmission) (DCM601A51) Unified ON/OFF Controller (DCS301BA61) Schedule Timer (DST301BA61) Control /Connection Interface Unification adaptor for computerised control (DCS302A52) DIII-NET, Daikin’s unique high speed multiple transmission system, links air conditioners and various other building equipment―in accordance with applications, scale and conditions―and transmits vast amounts of information between them. BMS Interface Adaptor for SkyAir Series (DTA112BA51) * No adaptor is required for the FCQ-B and FHQ-BV. Central Control Adaptor Kit (DTA107A55) Interface Adaptor for DIII-NET use (KRP928BB2S) (Obtain locally) SkyAir Packaged Air-conditioner Residential Air-conditioner Interface for use in BACnet® (DMS502B51) Di unit (DEC101A51) Dio unit (DEC102A51) Interface for use in LONWORKS® (DMS504B51) GHP Wiring adaptor for electrical appendices (KRP2A61/62/53) 03 53 Control Systems Central Remote Controller (DCS302CA61) VRV Building services equipment • Electrical equipment • Supply water and drainage equipment • Automatic fire alarm • Parking equipment • Lift • Ventilation equipment • Lighting • Crime and fire prevention equipment Caution: Limitation may apply to some models and functions. Please contact your local sales office for details. Consultation is necessary before employing this control system. Please contact your local sales office before making a purchase. Note: BACnet® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). LONWORKS® is a trademark of Echelon Corporation registered in the United States and other countries. 04 54 Control Systems Option List Operation Control System Optional Accessories No. 1 2 3 4 5 6-1 6-2 7 Item Type Wireless Remote controller Navigation remote controller (Wired remote controller) Simplified remote controller (Exposed type) Remote controller for hotel use (Concealed type) Adaptor for wiring Wiring adaptor for electrical appendices (1) Wiring adaptor for electrical appendices (2) Remote sensor (for indoor temperature) 8 Installation box for adaptor PCB 9 10 External control adaptor for outdoor unit Adaptor for multi tenant No. 1 2 3 4 5 6-1 6-2 7 Item Type Remote controller Wireless Navigation remote controller (Wired remote controller) Simplified remote controller (Exposed type) Remote controller for hotel use (Concealed type) Adaptor for wiring Wiring adaptor for electrical appendices (1) Wiring adaptor for electrical appendices (2) Remote sensor (for indoor temperature) 8 Installation box for adaptor PCB 9 External control adaptor for outdoor unit 10 Adaptor for multi tenant FXFQ-S FXFQ-P FXZQ-M FXUQ-A FXCQ-M FXKQ-MA BRC7F634F BRC7F634F BRC7E530W BRC7CB58 BRC7C62 BRC4C61 BRC1E62 Note 7 — — — KRP1B61 KRP1C63 KRP1BA57 KRP1B61 — KRP2A61 KRP2A62 KRP2A62 KRP2A61 KRP4AA53 KRP4AA53 KRP4AA53 KRP4AA51 KRP4AA51 KRCS01-4B KRCS01-1B KRCS01-4B KRCS01-1B Note 2, 3 Note 4, 6 KRP1H98 DTA104A62 DTA114A61 KRP1BA101 DTA104A62 FXSYQ-M FXDYQ-M(A) FXMQ-P BRC4C62 BRC4C62 BRC4C65 Note 5 BRC2C51 BRC3A61 KRP1C64 KRP2A61 KRP4AA51 KRCS01-4B KRP1B61 KRP2A61 KRP4AA51 KRCS01-1B — Note 2, 3 KRP1BA97 — FXHQ-MA BRC4C62 BRC7EA63W BRC1E62 Note 7 KRP1B61 KRP2A61 KRP4AA51 — DTA104A61 DTA104A61 DTA104A61 — DTA114A61 BRC4C65 BRC2C51 BRC3A61 KRP1B56 KRP2A53 KRP4A54 KRCS01-1B Note 4, 6 — KRP1B96 KRP1BA101 DTA104A61 DTA104A61 DTA104A53 — FXMQ-MA KRP4A96 KRP4A91 Note 2, 3 FXDQ-PB FXDQ-NB FXAQ-P BRC7EA618 — — KRP1BA54 — KRP2A62 KRP2A61 KRP4AA52 KRP4AA51 KRCS01-1B Note 3 KRP1CA93 Note 2, 3 KRP4AA93 DTA104A62 DTA104A61 — DTA114A61 FXLQ-MA FXNQ-MA BRC4C62 BRC2C51 BRC3A61 KRP1B61 KRP2A61 KRP4AA51 — DTA104A61 No. Item Model No. 1 Residential central remote controller 2 Central remote controller • Up to 16 groups of indoor units (128 units) can be easily controlled using the large LCD panel. ON/OFF, temperature settings and scheduling can be controlled individually for indoor units. DCS302CA61 • Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished individually or simultaneKJB311AA ously. Connectable up to 2 controllers in one system. DCS301BA61 • Up to 16 groups of indoor units(128 units) can be turned, ON/OFF individually or KJB212AA simultaneously, and operation and malfunction can be displayed. Can be used in combination with up to 8 controllers. KEK26-1A • Programmed time weekly schedule can be controlled by unified control for up to DST301BA61 64 groups of indoor units (128 units). Can turn units ON/OFF twice per day. Note 2 DCS303A51 2-1 Electrical box with earth terminal (3 blocks) 3 3-1 3-2 Unified ON/OFF controller Electrical box with earth terminal (2 blocks) Noise filter (for electromagnetic interface use only) 4 Function Schedule timer 7 For C(F)DK(X)S, KRP928BB2S FTK(X)S, FVXS, FLXS • Adaptors required to connect products other than those of the VRV System to the For FCQ-B, FFQ-B, DTA112BA51 high-speed DIII-NET communication system adopted for the VRV System. FHQ-BV, FBQ-B * To use any of the above optional controllers, an appropriate adaptor must be installed on the product unit to be controlled. Central control adaptor kit For UAT(Y)-K(A),FD-K DTA107A55 8 Wiring adaptor for other air-conditioner 9 DIII-NET Expander Adaptor 9-1 Fixing Plate for DⅢ‐NET Expander Adaptor 5 6 Interface adaptor for residential indoor units Interface adaptor for SkyAir-series DTA103A51 • Up to 1024 units can be centrally controlled in 64 different groups. • Wiring restrictions (max. length: 1,000m, total wiring length: 2,000m, max. number of branches: 16) apply to each adaptor. DTA109A51 For GYAQ8,10,13,16, 20,25ANV1 For GYAQ30ANV1, GYEQ20,30AN AGDTA109E1 COB850J The fixing plate is required when using DⅢ-NET Expander Adaptor. Note: 1. Installation box for adaptor must be obtained locally. 2. For residential use only. Cannot be used with other centralised control equipment. — Notes: 1. Installation box is necessary for each adaptor marked . 2. Up to 2 adaptors can be fixed for each installation box. 3. Only one installation box can be installed for each indoor unit. 4. Up to 2 installation boxes can be installed for each indoor unit. 5. Installation box is necessary for second adaptor. 6. Installation box is necessary for each adaptor. 7. Individual airflow direction, auto airflow rate and sensing sensor control can be set only via wired remote controller BRC1E62. Cannot be set via other remote controllers. Building Management System No. 1 1-1 Item intelligent Touch Controller Basic Option intelligent Touch Hardware Controller DIII-NET plus Hardware adaptor Model No. DCS601C51 DCS601A52 • Additional 64 groups (10 outdoor units) is possible. 1-2 Electrical box with earth terminal (4 blocks) Basic Hardware intelligent Touch Manager KJB411A 2 DCM601A51 Option Hardware iTM plus adaptor DCM601A52 2-1 intelligent Touch Manager 2-2 2-3 2-4 Di unit 3 3-1 3-2 Communication interface 4 5 DEC101A51 Dio unit Contact/analogue signal Function • Air-Conditioning management system that can be controlled by a compact all-in-one unit. DEC102A51 *1 Interface for use in BACnet ® DMS502B51 Optional DIII board DAM411B51 Optional Di board DAM412B51 *2 Interface for use in LONWORKS ® DMS504B51 Unification adaptor for computerised control DCS302A52 • Wall embedded switch box. • Air-conditioning management system that can be controlled by touch screen. • Additional 64 groups (10 outdoor units) is possible. Max. 7 iTM plus adaptors can be connected to intelligent Touch Manager. • 8 pairs based on a pair of ON/OFF input and abnormality input. Control Systems For indoor unit use System Configuration • 4 pairs based on a pair of ON/OFF input and abnormality input. • Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through BACnet ® communication. • Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET communication ports. Not usable independently. • Expansion kit, installed on DMS502B51, to provide 16 more wattmeter pulse input points. Not usable independently. • Interface unit to allow communications between VRV and BMS. Operation and monitoring of air-conditioning systems through LonWorks ® communication. • Interface between the central monitoring board and central control units. Notes: *1. BACnet ® is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). *2. LonWorks ® is a trademark of Echelon Corporation registered in the United States and other countries. *3. Installation box for adaptor must be obtained locally. 03 55 04 56 Air Treatment Equipment Lineup For Heat Pump series outdoor units only Combine fresh air treatment and air conditioning,supplied from a single system. Lineup Model Name FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1 Capacity Index 125 200 250 Fresh air treatment and air conditioning can be achieved with a single system by using heat pump technology—without the usual troublesome air supply and air discharge balance design. Fan coil units for air conditioning and an outdoor-air processing unit can be connected to the same refrigerant line. The results are enhanced design flexibility and a significant reduction in total system costs. * The system can operate with outdoor-air temperatures ranging from -5 to 43℃. Heating performance is somewhat adversely affected when the outdoor-air temperature is 0℃ or below. * When shipped from the factory, the thermostat is set at 18℃ for cooling and 25℃ for heating. The set temperature can be varied within the range of 13–25℃ during cooling operation, and 18–30℃ during heating operation, in the local setting mode using the wired remote controller. The temperature, however, is not displayed on the remote controller. * While in machine protection mode and depending on outdoor air conditions, discharge air temperature may not be at the set temperature. * The fan stops when operating in defrosting, oil returning and hot start operations. The fan also may stop due to mechanical protection control. • Ceiling mounted duct units with three differing capacities are available. These can be connected to GHP outdoor units to meet a variety of different requirements. Combination with GHP Airflow rate Air conditioning and outdoor air processing can be accomplished using a single system. • Optional equipment includes long-life filters. Air Conditioning Outdoor Air Supply Heating Supported Range Operation –5 Connection Conditions The following restrictions must be observed in order to maintain the indoor units connected to the same system. • GHP heat recovery series outdoor unit can not be connected. • When outdoor-air processing units are connected to GHP heat pump series 8-25 class outdoor unit, the total connection capacity index must be 50% to 100% of the capacity index of the outdoor units. When outdoor-air processing units are connected to GHP heat pump series 30 class outdoor unit, the total connection capacity index must be 80% to 108% of the capacity index of the outdoor unit. • When outdoor-air processing units and standard indoor units are connected to GHP heat pump series 8-25 class outdoor unit, the total connection capacity index of the outdoor-air processing units must not exceed 30% of the capacity index of the outdoor units. • A mixed combination of outdoor-air processing units and standard indoor units can not be connected to GHP heat pump series 30 class outdoor unit. 57 Supported Cooling Operation Range o td Ou e ur at r pe m Te ) ir WB A or (ºC % Indoor Unit 90 Indoor Unit 10 0% H R Re umi elat lat dity ive ive Hu m idi 32 ty Usage Limitations Outdoor-Air Processing Unit Fan Operation 15 19 30% R ve elati idity Hum (33.5) * Group control is not possible between this unit and standard type indoor units. Connect remote controllers to each unit. BRC1E62 “Nav Ease” (Wired remote controller) (option) • The “self-diagnosis function” indicates the occurrence and nature of abnormalities in the system by displaying codes on the remote controller. * It is not possible to change the discharge air temperature settings from the central control system. * Do not associate this equipment into zones with standard indoor units, as central control will not be possible. • Compatible with outdoor temperatures from -5℃ to 43℃. GHP Heat Pump series outdoor units • As with the GHP system, a variety of control systems can be deployed, including remote control from distances of up to 500 m. • A central control system compatible with the GHP can be installed. 1,080 m3/h 1,680 m3/h 2,100 m3/h FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1 • Outdoor-air processing units can be used without indoor units. • High-performance filters with dust collection efficiencies (JIS calorimetry) of 90% and 65% are also available as options. • The unit introduces outdoor air and adjusts the outdoor air temperature via fixed discharge temperature control, thereby reducing the air conditioning load. e lativ Re ity 20% umid H 43 Notes: 1. The data shown in the graph illustrates the supported operation ranges under the following conditions. Indoor and Outdoor Unit Effective piping length: 7.5 m Height differential: 0 m 2. The discharge temperature can be set using the remote controller. However, the actual temperature may not match the temperature setting under some circumstances due to the outdoor-air processing load or mechanical protection controls. 3. The system will not operate in fan mode when the outdoor air temperature is 5℃ or below. DCS302CA61 Central remote controller (option) • As with the GHP, the equipment employs the “super wiring system” so that the wiring linking indoor and outdoor units can also be utilised for central control. Notes: * Linked control of the product and the Heat Reclaim Ventilator is not supported. * This equipment is intended for the treatment of outdoor air only. It is not to be used for maintaining indoor air temperature. Install and use with standard indoor units. Be sure to position the air discharge openings of the product in positions where the airflow will not blow on people directly. When outdoor-air processing is in excess, the unit switches to thermo-off mode, and outdoor air flows into the room directly. * For outdoor ducts, be sure to provide heat insulation to prevent condensation. * Group control of the product and the standard indoor units is not supported. A separate remote controller should be connected to each individual unit. * The system will not operate in fan mode when the outdoor air temperature is 5℃ or below. * If the product is allowed to operate 24 hours a day, maintenance (part replacement, etc.) must be performed periodically. * Temperature setting and Power Proportional Distribution (PPD) are not possible even if the intelligent Touch Controller or the intelligent Touch Manager is installed. * The remote controller wired to the outdoor-air processing unit must not be set as the master remote controller. Otherwise, when set to “Auto,” the operation mode will switch according to the outdoor air conditions, regardless of the indoor temperature. Air Treatment Equipment Lineup Outdoor-Air Processing Unit 58 Air Treatment Equipment Lineup Standard Specifications Dimensions Indoor unit FXMQ125/200/250MFV1 28.0 kcal/h 7,700 12,000 15,000 Btu/h 30,400 47,400 59,400 8.9 13.9 17.4 0.548 0.638 Galvanised steel plate Airflow rate External static pressure 470X744X1,100 470X1,380X1,100 kW /s 300 466 583 Pa 225 275 255 m3/min 240 V 0.380 18 28 Air filter 35 *2 Liquid mm Gas mm Drain mm Machine weight Sound level *3 240 V 9.5 (flare) 15.9 (flare) Range of the discharge temperature *5 22.2 (brazing) kg 86 123 dB(A) 43 48 8 class and above Cooling 19 to 43℃ -5 to 15℃ Cooling 13 to 25℃ Heating 18 to 30℃ 3 *4. Only Heat Pump series outdoor units can be connected. Refer to page 57 for connection condition details. *5. Local setting mode. Not displayed on the remote controller. • This equipment cannot be incorporated into the remote group control of the GHP system. FXMQ200/250MFV1 11X100=1100 1200 1230 30 1 2 3 4 5 6 Liquid pipe connection Gas pipe connection Drain piping connection Electric parts box Ground terminal Name plate 7 8 9 10 11 12 Power supply wiring connection Transmission wiring connection Hanger bracket Discharge companion flange Water supply port Attached piping (Note. 1) 12 8 61 20- 7 hole (All around) 5X100=500 600 630 30 A View 8 DST301BA61 Wiring adaptor for electrical appendices (1) KRP4AA51 KAFJ371L140 KAFJ371L280 KAFJ372L140 KAFJ372L280 KAFJ373L140 KAFJ373L280 KDJ3705L140 KDJ3705L280 Drain pump kit Adaptor for wiring Notes: *1. Filter chamber has a suction-type flange. (Main unit does not.) • Dimensions and weight of the equipment may vary depending on the options used. • Some options may not be usable due to the equipment installation conditions, so please confirm prior to ordering. KDU30L250VE KRP1B61 • Some options may not be used in combination. • Operating sound may increase somewhat depending on the options used. 200 346 360 330 200 1230 B View (For FXMQ200MFV1) 1004 360 Colourimetric method 90% 16-M5 hole (All around) KRP2A61 Wiring adaptor for electrical appendices (2) 5X200=1000 7 7 16-M5 hole (All around) 7 10-M5 hole (All around) 2X200=400 580 630 B View Air Treatment Equipment Lineup DCS301BA61 Schedule timer 250 Unified ON/OFF controller 200 DCS302CA61 360 BRC1E62 Central remote controller Colourimetric method 65% FXMQ250MFV1 250 Operation remote controller FXMQ200MFV1 330 FXMQ125MFV1 250 Operation/control D 20- 4.7 hole 32- 4.7 hole 32- 4.7 hole FXMQ125MFV1 245 60 32- 7 hole (All around) C 5X100=500 11X100=1100 11X100=1100 580 Long-life replacement filter Filters 613 760 B 685 1296 1296 Notes: 1. The attached piping in the diagram is for FXMQ200MFV1 and FXMQ250MFV1 only. The gas piping connection port ( 2 in the diagram) has a different bore form with FXMQ125MFV1. 2. An air filter is not supplied with this unit. Be sure to mount an air filter in the suction side.[Use a filter with dust collection efficiency of at least 50% (gravimetric method). This is available as an option.] 3. For outdoor ducts, be sure to provide heat insulation to prevent condensation. A View Model 59 Suction side (Note.2) B View Indoor unit Filter chamber *1 5 *These diagrams are based on FXMQ200 and FXMQ250MFV1. Options High-efficiency filter 2 11 6 4 30 1100 250 Notes: *1. Specifications are based on the following conditions; • Cooling: Outdoor temp. of 33°CDB, 28°CWB (68% RH), and discharge temp. of 18°CDB. • Heating: Outdoor temp. of 0°CDB, -2.9°CWB (50% RH), and discharge temp. of 25°CDB. • Equivalent reference piping length: 7.5 m (0 m horizontal) *2. An intake filter is not supplied, so be sure to install the optional long-life filter or high-efficiency filter. Please mount it in the duct system of the suction side. Select a dust collection efficiency (gravity method) of 50% or more. *3. Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. These values are normally somewhat higher during actual operation as a result of ambient conditions. A View 10 class and above Heating 1 Discharge side PS1B female thread Connectable outdoor units *4 Operation range (Fan mode operation between 15 and 19°C) 19.1 (brazing) 1100 or more (Service space) Inspection hole 600 or more 390 Motor output 470 mm Dimensions (HxWxD) D (All around) 296 0.359 50 kW Casing 25 Power consumption Table of dimensions Model A FXMQ125MFV1 744 FXMQ200MFV1 1380 FXMQ250MFV1 1380 3X100=300 kW 360 330 3X100=300 Heating capacity *1 390 22.4 296 95,500 14.0 kW A 76,400 B 24,100 47,800 Approx. 150 19,300 Btu/h Liquid piping diameter 9.5 9.5 9.5 C 12,000 650 or more (Service space) kcal/h Gas piping diameter 15.9 19.1 attached piping 22.2 attached piping Model FXMQ125MFV1 FXMQ200MFV1 FXMQ250MFV1 1-phase 220 - 240 V (also required for indoor units), 50 Hz Cooling capacity *1 Refrigerant piping FXMQ250MFV1 25 Power supply FXMQ200MFV1 360 330 FXMQ125MFV1 Local connection piping size 1148 3X100=300 Model Fan 9 10 Ceiling Mounted Duct Type 250 Type 5X200=1000 1230 B View (For FXMQ250MFV1) 60 Air Treatment Equipment Lineup Heat Reclaim Ventilator — VAM series Air conditioning load reduced by approximately 31%! 23% Total heat exchange ventilation Model Names VAM150GJVE, VAM250GJVE, VAM350GJVE, VAM500GJVE, VAM650GJVE, VAM800GJVE, VAM1000GJVE, VAM1500GJVE, VAM2000GJVE Heat Reclaim Ventilator remote controller* BRC301B61 (Option) Improved Enthalpy Efficiency 2 Higher External Static Pressure Enhanced Energy Saving Functions 1 * This remote controller is used in case of independent operation of Heat Reclaim Ventilator. This VAM series provides higher enthalpy efficiency 1, due to the greatly enhanced performance of the thin film element. Furthermore, improved external static pressure 2 offers more flexibility for installation. Along with these three outstanding improvements, the nighttime free cooling operation contributes to energy conservation and more comfortable space. EA (Exhaust air to outdoors) For models: VAM150/250/350/650/800/1000/2000GJVE 2 For models: VAM150/350/500GJVE 1 Due to the thinner film… •Decreases the moisture resistance of the partition sheets drastically. •Realises more space for extra layers in the element, Thickness of resulting in increased effective area that supply and the partition sheet exhaust air can be exposed to. Moisture absorption increased by approx. 10%! Indoor Sheet structure Outdoor High-humidity air Molecule of water Miscellaneous gas CO2 molecule, etc. Exhaust air (Fresh air from outdoors) Reduces air conditioning load by not running the Heat Reclaim Ventilator while air is still clean soon after the air conditioner is turned ON. Precise, thin-film material RA (unclean indoor air) Outdoor air (fresh air) Supply air 2% Pre-cool, Pre-heat Control Exhaust air RA (Return air from room) Automatically switches the ventilation mode (Total Heat Exchange Mode/Bypass Mode) according to the operating status of the air conditioner. Enthalpy efficiency drastically improved by employing thin film element! (VAM-GJ model) SA OA 6% Auto-ventilation Mode Changeover Switching This unit recovers heat energy lost through ventilation and curbs room temperature changes caused by ventilation, thereby conserving energy and reducing the load on the air conditioning system. Low-humidity air Moisture exchange efficiency is greatly improved by using optimised thinner films and moisture-absorption materials in the element. Furthermore, miscellaneous gas barrier properties are maintained by decreasing the porosity in the moisture-absorption materials. 31% (Supply air to room) Daikin air conditioner • The air conditioning load reduction values are based on the following conditions; Application: Tokyo office building Building form: 6 floors above ground, 2 floors underground, floor area 2,100 m2 Personnel density: 0.25 person/m2 Ventilation volume: 25 m3/h Indoor air conditioning level: summer 25℃ 50% RH, intermediate seasons 24℃ 50% RH, winter 22℃ 40% RH Operating time: 2745 hours (9 hours per day, approx. 25 days per month) Calculation method: simulation based on "MICRO-HASP/1982" of the Japan Building Mechanical and Electrical Engineers Association. Indoor unit • ON/OFF signal • Cooling/Heating mode signal • Set temperature signal • Ventilation signal • Operating mode signal • Filter cleaning signal • Failure detection signal Interlocking 61 Heat Reclaim Ventilator Compact Equipment Energy Conservation With a height of just 306 mm, the unit easily fits in limited spaces, such as above ceilings. Air conditioning load reduced by approximately 31%! * For VAM500GJVE Air Conditioning Load Reduced by Approximately 20% 0% Normal ventilation fan Nighttime free cooling operation*1 LCD remote controller for indoor unit 306 mm • The air conditioning load reduction values may vary according to weather and other environmental conditions at the location of the machine's installation. Air conditioning load reduction (%) SA Standard operation at temperatures down to -15℃. -15˚CDB -20 -10 50˚CDB 0 10 20 30 40 50 VAM-GJ Interlocked operation with air conditioner Air conditioning sensible heat load reduced by Nighttime free cooling operation is an energy-conserving function that works at night when air *2 conditioners are off. By ventilating rooms containing office equipment that raises the room approx. temperature, nighttime free cooling operation reduces the The indoor accumulated heat is discharged at night. cooling load when air conditioners are turned on in the This reduces the air conditioning load the next day thereby increasing efficiency. morning. It also alleviates feelings of discomfort in the morning caused by heat accumulated during the night. 5% ! •Nighttime free cooling operation only works to cool and if connected to Building Multi or VRV systems. •Nighttime free cooling operation is set to “off” in the factory settings, so if you wish to use it, request your dealer to turn it on. Cold Climate Compatible VAM-GJ Individual operation *1 This function can be operated only when interlocked with air conditioners. *2 Value is based on the following conditions: • Cooling operation performed from April to October. • Calculated for air conditioning sensible heat load only (latent heat load not included). Cold air Exhaust heat Generated heat Heat is discharged. Indoor unit Exhaust heat Indoor unit Air Treatment Equipment Lineup The Heat Reclaim Ventilator Creates a High-Quality Environment by Interlocking with the Air Conditioner Comfortable! The load is small so the temperature is rapidly reduced to a comfortable level. *Interlocked operation with an air conditioner 62 Air Treatment Equipment Lineup Specifications 1-phase, 220-240 V/220 V, 50 Hz/60 Hz % High Low For Heating Ultra-High % High Low For Cooling Ultra-High % High Low Power Consumption Heat Ultra-High Exchange High Mode W Low Bypass Mode Sound Level 79 74 75 72 78 72 77 75 79 74 75 72 78 72 77 84 79 82 80 77 74 80.5 75.5 79 72 71 70 67 67.5 65 70 65 72 72 71 70 67 67.5 65 70 65 72 76 74 77 74 71.5 67.5 72.5 67 75 66 63 66 55 61 61 64 61 62 66 63 66 55 61 61 64 61 62 70 66 70 59 64 64 68.5 64 66 125 137 200 248 342 599 635 1,145 1,289 111 120 182 225 300 517 567 991 1,151 57 60 122 128 196 435 476 835 966 125 137 200 248 342 599 635 1,145 1,289 High 111 120 182 225 300 517 567 991 1,151 Low 57 60 122 128 196 435 476 835 966 27-28.5 27-29 31.5-33 33-35.5 34-36 39-40.5 39.5-41.5 39.5-41.5 41.5-43.5 26-27.5 26-27.5 30-31.5 31.5-34 33-34.5 37-39.5 37.5-39.5 37.5-39.5 39-43 20.5-21.5 21-22 23-25 25-28.5 27.5-29.5 35-37.5 35-37.5 35-37.5 36-39 28.5-29.5 28.5-30.5 33-34.5 34.5-36 35-37.5 40.5-42 40.5-42.5 41-43 43-45.5 High 27.5-28.5 27.5-29 31.5-33 33-34.5 33-35.5 38.5-40 38.5-40.5 39.5-41 40.5-45 Low 22.5-23.5 22.5-23 24.5-26.5 25.5-28.5 27.5-30.5 36-38.5 36-38.5 36.5-38 37.5-39.5 Ultra-High W Heat Ultra-High dB(A) Exchange High Mode Low Bypass Mode 75 79 Ultra-High dB(A) Casing Galvanised steel plate Insulation Material Self-extinguishable polyurethane foam Dimensions (HXWXD) Machine Weigh mm 278X810X551 kg 24 Heat Exchange System 306X879X800 338X973X832 32 45 External Static Pressure 129 Ultra-High m3/h 150 250 350 500 650 800 1,000 1,500 2,000 High 150 250 350 500 650 800 1,000 1,500 2,000 Low 100 155 230 320 500 700 860 1,320 1,720 Ultra-High 41 69 97 138 180 222 277 416 555 High /s 41 69 97 138 180 222 277 416 555 Low 27 43 63 88 138 194 238 366 477 120 70 169 105 85 133 168 112 116 High 106 54 141 66 53 92 110 73 58 Low 56 24 67 32 35 72 85 56 Ultra-High Pa Motor Output kW Connection Duct Diameter mm 0.030X2 100 0.090X2 150 0.140X2 200 0.280X2 250 45 Silencer (Option) Duct (Obtain locally) Thermal insulation material (Obtain locally) Option List Type Item Heat Reclaim Ventilator remote controller Residential central remote controller Centralised Central remote controller controlling Unified ON/OFF controller device Schedule timer Wiring adaptor for electrical appendices For humidifier Installation box for adaptor PCB For heater control kit Notes: 1. 2. 3. 4. OA EA BRC301B61 DCS303A51 *1 DCS302CA61 DCS301BA61 DST301BA61 KRP2A61 KRP50-2 KRP50-2A90 (Mounted electric component assy of Heat Reclaim Ventilator) BRP4A50 FXFQ-S FXDQ-PB FXLQ-MA Type For wiring (indoor unit of GHP) FXFQ-P FXZQ-M FXUQ-A FXCQ-M FXKQ-MA FXDQ-NB FXSYQ-M FXDYQ-M(A) FXMQ-P FXMQ-MA FXHQ-MA FXAQ-P FXNQ-MA Installation box for adaptor PCB Sirocco fan Unit Ambient Condition KRP1C63 KRP1BA57 KRP1C67 KRP1B61 KRP1B61 KRP1B56 KRP1B61 Notes 2, 3 Note 4, 6 — Notes 2, 3 — Notes 4, 6 Notes 5 — KRP1H98 KRP1BA101 KRP1B96 KRP1BA101 KRP4A91 Installation box is necessary for each adaptor marked . Up to 2 adaptors can be fixed for each installation box. Only one installation box can be installed for each indoor unit. Up to 2 installation boxes can be installed for each indoor unit. KRP1C64 KRP1B61 KRP1BA54 — KRP1B61 Notes 2, 3 Notes 2, 3 — Note 3 — KRP4A96 KRP1CA93 KRP4AA93 5. Installation box is necessary for second adaptor. 6. Installation box is necessary for each adaptor. 7. *1 For residential use only. When connected with a Heat Reclaim Ventilator (VAM), you can only switch the power ON/OFF. Cannot be used with other centralised control equipment. Type VAM150GJVE VAM250GJVE VAM350GJVE VAM500GJVE VAM650GJVE VAM800GJVE VAM1000GJVE VAM1500GJVE VAM2000GJVE — KDDM24B50 KDDM24B100 KDDM24B100X2 Nominal pipe diameter mm — 200 250 High efficiency filter KAF242H25M KAF242H50M KAF242H65M KAF242H80M KAF242H100M KAF242H80MX2 KAF242H100MX2 Air filter for replacement KAF241G25M KAF241G50M KAF241G65M KAF241G80M KAF241G100M KAF241G80MX2 KAF241G100MX2 Flexible duct (1 m) K-FDS101D K-FDS151D K-FDS201D K-FDS251D Flexible duct (2 m) K-FDS102D K-FDS152D K-FDS202D K-FDS252D Duct adaptor — YDFA25A1 Nominal pipe diameter mm — 250 Item Silencer 0.280X4 350 -15℃–50℃DB, 80%RH or less Notes: 1. Sound level is measured at 1.5 m below the centre of the body. 2. Airflow rate can be changed over to Low mode or High mode. 3. Sound level is measured in an anechoic chamber. Sound level generally becomes greater than this value depending on the operating conditions, reflected sound, and peripheral noise. 4. The sound level at the air discharge port is about 8 dB(A) higher than the unit's sound level. 5. The specifications, designs and information given here are subject to change without notice. 6. Temperature Exchange Efficiency is the mean value between cooling and heating. 7. Efficiency is measured under the following conditions: Ratio of rated external static pressure has been maintained as follows; outdoor side to indoor side = 7 to 1. 8. In conformance with JIS standards (JIS B 8628), operating sound level is based on the value when one unit is operated, with the value converted for an anechoic chamber. This is transmission sound from the main unit, and does not include sound from the discharge grille. Thus it is normal for the sound to be louder than the indicated value when the unit is actually installed. 9. Sound level from the discharge port causes the value to be approximately 8 dB(A) (models with the airflow rate of less than 150 to 500 m3/h) to approximately 11 dB(A) (models with the airflow rate of 650 m3/h or more) greater than the indicated value. Furthermore, fan rotation and noise from the discharge grille may increase depending on the on-site duct resistance conditions. Please consider noise countermeasures when installing the unit. 10. With large models in particular (1500 and 2000 m3/h models), if the supply air (SA) grille is installed near the main unit, the noise of the main unit may be heard from the discharge grille via the duct, and this will result in a marked increase in noise. In such cases, if peripheral effects are included (such as reverberation of the floor and walls, combination with other equipment, and background noise), sound level may be as much as 15 dB(A) higher than the indicated value. When installing a large model, please provide as much separation as possible between the main unit and the discharge grille. If the equipment and discharge grille are near each other, please consider countermeasures such as the following: •Use a sound-muffling box, flexible duct and sound-muffling air supply/discharge grilles •Decentralised installation of discharge grilles 11. When installing in a location with particularly low background noise such as a classroom, please consider the following measures to avoid transmission sound from the main unit: •Use of ceiling materials with high sound insulating properties (high transmission loss) •Methods of blocking sound transmission, for example, by adding sound insulating materials around the bottom of the sound source. Alternatively, consider supplementary methods such as installing the equipment in a different location (corridor, etc.) 63 SA 157 Multidirectional fibrous fleeces Type Airflow Rate 67 Specially processed nonflammable paper Air Filter Airflow Rate 55 Round hood (Obtain locally) Branch duct (Obtain locally) Air to air cross flow total heat (Sensible heat + latent heat) exchange Heat Exchange Element Material Fan 387X1,111X832 387X1,111X1,214 785X1,619X832 785X1,619X1,214 High efficient filter (Option) SA Additional function Enthalpy Exchange Efficiency 79 Controlling device Ultra-High Flexible duct (Option) RA PC Board Adaptor Power Supply Temp. Exchange Efficiency Air suction/discharge grille (Obtain locally) VAM150GJVE VAM250GJVE VAM350GJVE VAM500GJVE VAM650GJVE VAM800GJVE VAM1000GJVE VAM1500GJVE VAM2000GJVE PC board adaptor for heater control kit (BRP4A50) When the installation of an electric heater is required in a cold region, this adaptor with an internal timer function eliminates the complicated timer connecting work that was necessary with conventional heaters. Indoor RA EA Heat Reclaim Ventilator SA BRP4A50 Thermostat (Obtain locally) (OFF when the temperature is at or more than 5℃) Outdoor Heater (Obtain locally) OA Thermostat (Obtain locally) (ON when the temperature is at or below -10℃) Power supply (Obtain locally) Relay box Notes when installing Examine fully an installation place and specification for using the electric heater based on the standard and regulation of each country. Supply the electric heater and safety production devices such as a relay and a thermostat, etc of which qualities satisfy the standard and regulation of each country at site. Use a non-inflammable connecting duct to the electric heater. Be sure to allow 2 m or more between the electric heater and the Heat Reclaim Ventilator for safety. Air Treatment Equipment Lineup MODEL Options For the Heat Reclaim Ventilator, use a different power supply from that of the electric heater and install a circuit breaker for each. 64 Memo