DEVICE SYMBOL LEGEND DESCRIPTION HOMERUN TO PANELBOARD. NUMBER OF ARROWS INDICATES NUMBER OF CIRCUITS. (EXAMPLE: HOMERUN TO PANEL L211 CKTS. #1 AND #3.) L211-1,3 BFG BLDG BELOW FINISHED GRADE BUILDING C CB CKT CR CONDUIT CIRCUIT BREAKER CIRCUIT CONTROL RELAY CONDUIT DOWN DIRECT CURRENT DRAWING CONDUIT, STUBBED AND CAPPED AS SHOWN DC DWG SYMBOL xxA CONDUIT UP xxA DIRECT CONNECTION TO EQUIPMENT. HAND HOLE HORSEPOWER JB JUNCTION BOX KCMIL KS KVA KW THOUSAND CIRCULAR MILS KEY SWITCH KILOVOLT-AMPERE KILOWATT LED LS LV LIGHT EMITTING DIODE LIMIT SWITCH LOW VOLTAGE MH MLO MS MAN HOLE MAIN LUGS ONLY MOTION SENSOR N N/A NC NEC NEX NEUTRAL NOT APPLICABLE NORMALLY CLOSED NATIONAL ELECTRICAL CODE REPLACE EXISTING WIRING DEVICE AND FACEPLATE WITH NEW. BACK BOX AND CONDUIT SHALL REMAIN. NL NO NTS NIGHT LIGHT NORMALLY OPEN NOT TO SCALE OC OEM ON CENTER ORIGINAL EQUIPMENT MANUFACTURER FLEXIBLE CONDUIT CONNECTION TO EQUIPMENT. ADA DOOR PUSH PLATE. PANELBOARD CEILING MOUNTED HEAT DETECTOR. MAGNETIC STARTER AND FUSED DISCONNECT SWITCH, STARTER SIZE AND FUSE SIZE AS INDICATED. CIRCUIT BREAKER SWITCH. X LUMINAIRE, RECESSED OR SURFACE MOUNTED, AS INDICATED ON DRAWINGS. FIRE ALARM VISUAL ONLY STROBE, TOP OF LENS MOUNTED AT 96" AFF UNLESS OTHERWISE NOTED. FS TR T FIRE ALARM HORN STROBE, TOP OF LENS MOUNTED AT 96" AFF UNLESS OTHERWISE NOTED. SWITCH, SINGLE POLE, MOUNTED AT 42" AFF TO CENTER UNLESS OTHERWISE NOTED. 3 - THREE WAY M - MOTOR RATED TOGGLE SWITCH F Z LUMINAIRE, RECESSED, WIRED FOR MULTILEVEL CONTROL. P PHOTOCELL. M MOTION SENSOR, WALL MOUNTED, MOUNTED AT 42" AFF TO CENTER UNLESS OTHERWISE NOTED.\ M = MULTI-LEVEL SWITCH M MOTION SENSOR, CEILING MOUNTED. R CEILING MOUNTED LOW VOLTAGE POWER PACK FOR CEILING MOUNTED MOTION SENSOR. LUMINAIRE, RECESSED, WITH EMERGENCY BATTERY PACK AND BALLAST. LUMINAIRE, RECESSED OR PENDENT MOUNTED AS INDICATED ON DRAWINGS WALL WASH LUMINAIRE, RECESSED. EXIT SIGN, SINGLE FACE CEILING MOUNTED WITH CHEVRONS AS INDICATED ON DRAWINGS. CIRCUIT BREAKER ED PROFES ER S T I N E S G E N 86683 Digital Signature FIRE ALARM PULL STATION, MOUNTED AT 42" AFF UNLESS OTHERWISE NOTED. FS TR T CIRCUIT BREAKER, ENCLOSED OREGON Y M IN 0 08, 2 P E. EXPIRES: 12-31-2016 RELAY MODULE. M UTILITY METER & CURRENT TRANSFORMERS ST SHUNT TRIP GROUND COMBINATION POWER/DATA FLOORBOX. EXIT SIGN,TWO FACES, CEILING MOUNTED WITH CHEVRONS AS INDICATED ON DRAWINGS. ELECTRICAL CONNECTION AUDIO / VISUAL FLOORBOX. EXIT SIGN, SINGLE FACE, WALL MOUNTED WITH CHEVRONS AS INDICATED ON DRAWINGS. LUMINAIRE, WALL SCONCE. WALL MOUNTED SECURITY CAMERA. LUMINAIRE, WALL MOUNTED. LOW VOLTAGE DATA OUTLET, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. PROVIDE 1" CONDUIT WITH BUSHING FROM BOX TO NEAREST AVAILABLE CEILING SPACE. PROVIDE BUSHING. REFERENCE DETAILS ON THIS SHEET FOR TYPE DETAILS. C - MOUNTED 6" ABOVE COUNTER LUMINAIRE, TRACK LIGHTING. PHASE PB PE PNL XXX DISCONNECT SWITCH, UN-FUSED TYPE, SIZE AS INDICATED ON DRAWINGS. "xxA" INDICATES AMPERAGE. CONDUIT AND CONDUCTORS INSTALLED BELOW GRADE, BELOW SLAB, OR CONCEALED. WIRE, CONTINUED. HH HP DUCT SMOKE DETECTOR WITH REMOTE ALARM TRANSFORMER L NA IO R GRAFIK EYE GROUND FAULT CIRCUIT INTERRUPTER GROUND RECEPTACLE, CEILING MOUNTED EMAIL: info@ADWarchitect.com A GE GFCI GND CEILING MOUNTED SMOKE DETECTOR. DESCRIPTION A FULL LOAD AMPERES RECEPTACLE, TAMPER PROOF SYMBOL NJ FLA DESCRIPTION M ELECTRICAL METALLIC TUBING EXISTING DEVICE SHALL REMAIN SYMBOL BE EMT ETR DESCRIPTION 2 RY SYMBOL ONE LINE DIAGRAM SYMBOL LEGEND 1 AMPERE AMPERE FRAME ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE TRIP AMERICAN WIRE GAUGE 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 ER A AF AFF AFG AT AWG ELECTRICAL INDICATOR SYMBOLS REG I E ELECTRICAL ABBREVIATIONS JUNCTION BOX, xx INDICATES IDENTIFIER IF ANY PULL BOX, PANIC BUTTON, PUSH BUTTON PHOTE EYE PANEL MOTOR / EXHAUST FAN. QS LUTRON QS MODULE REX REMOVE EXISTING DEVICE / EQUIPMENT SW SWBD SWITCH SWITCHBOARD TYP TYPICAL UG UNO UNDERGROUND UNLESS NOTED OTHERWISE VA VDC VOLT-AMPERE VOLTS DIRECT CURRENT W WP WS WATT, WIRE WEATHERPROOF LUTRON LOW VOLTAGE WALL SWITCH XFMR TRANSFORMER Y WYE +72 MOUNTING UNITS EXPRESSED IN INCHES TO CENTERLINE ABOVE FINISHED FLOOR OR GRADE. ONE POLE TWO POLE THREE POLE FOUR POLE 1P 2P 3P 4P CEILING MOUNTED LOW VOLTAGE OUTLET. REFERENCE DETAILS ON THIS SHEET FOR TYPE DETAILS. RECEPTACLE, NEMA CONFIGURATION AS INDICATED ON THE DRAWINGS, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. RECEPTACLE, SINGLE OUTLET, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. X X X GFCI RECEPTACLE, DUPLEX, MOUNTED AT 18" AFF TO CENTER UNLESS OTHERWISE NOTED. C - MOUNTED HORIZONTALLY 6" ABOVE COUNTER WP - WEATHERPROOF RECEPTACLE, DUPLEX, MOUNTED AT 18" AFF TO CENTER UNLESS OTHERWISE NOTED. C - MOUNTED HORIZONTALLY 6" ABOVE COUNTER. PNT - PRINTER, VERIFY HEIGHT WITH ARCHITECT TV - TELEVISION, VERIFY HEIGHT WITH ARCHITECT. UCR - UNDERCABINET REFRIGERATOR WP - WEATHER PROOF XX" - DIMENSIONED HEIGHT R CATV COAX OUTLET, SINGLE F TYPE CONNECTOR, MOUNTED AT 18" AFF UNLESS OTHERWISE NOTED. P. PROVIDE 1" CONDUIT WITH BUSHING FROM BOX TO NEAREST AVAILABLE CEILING SPACE. PAGING / INTERCOM HANDSET OUTLET, MOUNTED AT 42" AFF UNLESS OTHERWISE NOTED. PROVIDE 1" CONDUIT WITH BUSHING FROM BOX TO NEAREST AVAILABLE CEILING SPACE. CEILING MOUNTED WIRELESS ACCESS POINT. S CEILING MOUNTED INTERCOM SPEAKER BRANCH CIRCUIT PANELBOARD ELECTRICAL SYMBOL LEGEND, ABBREVIATIONS & INDICATORS E-001 1 GENERAL SHEET NOTES 272005.W01 272005.W01 REFERENCE KEY NOTES 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 EMAIL: info@ADWarchitect.com 272005.J45 272005.J45 272005.J11 SHEET KEY NOTES 1. 272005.J45 xxx. 272005.J11 REG I E L NA IO R ED PROFES ER S T I N E S G E N 86683 SCALE: N/A IN 1 0 08, 2 P E. EXPIRES: TYPE IDENTIFICATION ER 3 M A COMBINATION POWER/DATA FLOORBOX SUBPLATE DETAIL Y A NJ TYPE IDENTIFICATION SCALE: N/A OREGON M 2 SCALE: N/A TYPE WD FACEPLATE BE 1 TYPE D FACEPLATE 2 RY Digital Signature 12-31-2016 TYPE IDENTIFICATION TYPE D: TYPE : ONE JACK, FACEPLATE MOUNTED AT 18" AFF, UON. ONE JACK, FACEPLATE MOUNTED IN CEILING. FACEPLATE SHALL BE STAINLESS STEEL. TYPE WD: TWO JACKS, FACEPLATE MOUNTED AT 18" AFF, UON. TYPE : TWO DUPLEXES, ONE RJ45, ONE RJ11. ELECTRICAL EQUIPMENT NAMEPLATE SCHEDULE ITEM NAME PLATE DESCRIPTION 1-1/2" NPT 1 2 PANEL H PANEL H2 NAMEPLATE / TAG Dwg. SYMBOL Dwg. REF. NAMEPLATE H HLES E-102 NAMEPLATE H2 HLES E-102 3 FUSED DISCONNECT SWITCH FDS-PC-1 NAMEPLATE FDS-PC-1 HLES E-102 4 FUSED DISCONNECT SWITCH FDS-PC-2 NAMEPLATE FDS-PC-2 HLES E-102 5 PHASE CONVERTER PC-1 NAMEPLATE PC-1 HLES E-102 6 PHASE CONVERTER PC-2 NAMEPLATE PC-2 HLES E-102 NAMEPLATE H PSES E-102 NAMEPLATE H RSES E-102 COMMENTS 3/4" NPT 4 AUDIO / VISUAL FLOORBOX DETAIL 7 SCALE: N/A TYPE IDENTIFICATION TYPE : 8 PANEL H PANEL G2 ONE 3 4" C FLEXIBLE CONNECTION FOR INTERCOM WIRING. ELECTRICAL DETAILS & NAMEPLATE SCHEDULE E-002 2 GENERAL SHEET NOTES REFERENCE KEY NOTES 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 EMAIL: info@ADWarchitect.com SHEET KEY NOTES xxx. LED LIGHT FIXTURE SCHEDULE DRIVER / BALLAST DRIVER / BALLAST QTY. EMERGENCY DRIVER / BALLAST VOLTS LOAD MFR. 3500K M A 1500 LM Y A NA NJ LED STANDARD 0-10V 1 NO UNIV. 23 WATTS GOTHAM ICO-35-15-4 OREGON M D RECESSED OPEN 6" DIAMETER, 6" HIGH DOWNLIGHT, WIDE BEAM DISTRIBUTION, 80CRI, DIE-CAST ALUMINUM HOUSING, SELF-FLANGED SEMI-SPECULAR REFLECTOR, WHITE FLANGE, AND WET LOCATION LISTED. LD6A-15-D010TE-ERW6A15-8-35-6LW 1-H-WF Digital Signature BE PORTFOLIO MODEL NUMBER IN 0 08, 2 DE FIXTURE SHALL BE SIMILAR TO TYPE 'D' EXCEPT WIRED TO LOCAL EMERGENCY INVERTER. R2 FLUORESCENT 2' x 4' X 3.25"H RECESSED LUMINAIRE WITH COLD ROLLED STEEL HOUSING, ACRYLIC PRISMATIC LENS (#12 PATTERN), FLAT WHITE STEEL DOOR, WHITE ENAMEL FINISH, AND SUITABLE FOR DAMP LOCATIONS. FIXTURE SHALL BE USED IN BOTH LAY-IN AND DRYWALL CEILINGS. CONTRACTOR SHALL VERIFY TRIM TYPE REQUIRED. R2E R2S UC3 UC4 W2 W3 X X2 T8 FLUORESCENT 2' x 4' X 3.25"H RECESSED LUMINAIRE WITH COLD ROLLED STEEL HOUSING, ACRYLIC PRISMATIC LENS (#12 PATTERN), FLAT WHITE STEEL DOOR, WHITE ENAMEL FINISH PAINTED AFTER FABRICATION, AND SUITABLE FOR DAMP LOCATIONS. FIXTURE SHALL BE USED IN BOTH LAY-IN AND DRYWALL CEILINGS. CONTRACTOR SHALL VERIFY TRIM TYPE REQUIRED. T8 FLUORESCENT 2' x 4' X 4"H SURFACE MOUNTED LUMINAIRE WITH COLD ROLLED STEEL HOUSING, ACRYLIC PRISMATIC LENS (#12 PATTERN), FLAT WHITE STEEL DOOR, WHITE ENAMEL FINISH, AND SUITABLE FOR DAMP LOCATIONS. T8 3' X 4.5" UNDERCABINET MOUNTED LED FIXTURE WITH STEEL HOUSING, INTEGRAL ROCKER-STYLE SWITCHAND WHITE FINISH. FIXTURE SHALL BE CONTINUOUSLY MOUNTED WHERE SHOWN ON THE DRAWINGS. 4' X 4.5" UNDERCABINET MOUNTED LED FIXTURE WITH STEEL HOUSING, INTEGRAL ROCKER-STYLE SWITCH, AND WHITE FINISH. FIXTURE SHALL BE CONTINUOUSLY MOUNTED WHERE SHOWN ON THE DRAWINGS. 18' DIAMETER x 12" DEEP x 9"H QUARTER SPHERE WALL MOUNTED LUMINAIRE WITH DIE-CAST ALUMINUM HOUSING, TYPE II DISTRIBUTION, BLACK FINISH, AND PUSH-BUTTON TYPE PHOTO CONTROL. 18' DIAMETER x 12" DEEP x 9"H QUARTER SPHERE WALL MOUNTED LUMINAIRE WITH DIE-CAST ALUMINUM HOUSING, TYPE III DISTRIBUTION, BLACK FINISH, AND PUSH-BUTTON TYPE PHOTO CONTROLL . CEILING MOUNTED EXIT SIGN, GREEN LETTERS, POLYCARBONATE HOUSING, WHITE FINISH EMERGENCY BATTERY, TEST SWITCH / POWER INDICATOR LIGHT, SELF-DIAGNOSTICS TEST UNIT, UL 924 LISTED, AND UL DAMP LOCATION LISTED. CEILING MOUNTED EXIT SIGN WITH TWIN EGRESS LAMPS, GREEN LETTERS, POLYCARBONATE HOUSING, WHITE FINISH EMERGENCY BATTERY, TEST SWITCH / POWER INDICATOR LIGHT, SELF-DIAGNOSTICS TEST UNIT, UL 924 LISTED, AND UL DAMP LOCATION LISTED. LED LED 2 2 2 N/A N/A N/A N/A N/A 1600 LM 2400 LM 3500K 3500K 3500K 3500K 3500K LED N/A 4354 LM 3000K LED N/A 3996 LM 3000K LED LED NA NA NA NA NA NA ELECTRONIC ELECTRONIC ELECTRONIC STANDARD 0-10V STANDARD 0-10V STANDARD 0-10V STANDARD 0-10V NA NA 1 1 1 1 1 NO YES NO NO NO UNIV. UNIV. UNIV. UNIV. UNIV. 53 WATTS 53 WATTS 61 WATTS 28 WATTS 37 WATTS CALCULITE METALUX 2-X-C8-232-A-UNV-EB8-1 LITHONIA GT SERIES DAY-BRITE METALUX TG8 2-X-C8-232-A-UNV-EL-EB8-1 LITHONIA GT SERIES DAY-BRITE METALUX TG8 2-M-2-32-A-UNV-EB8 LITHONIA M Series DAY-BRITE FAIL SAFE SMR UCL-3-LD2-35-A12125-ED-UNV-RSW LITHONIA SPECTRA-SF DAY-BRITE FAIL SAFE LINCS UCL-3-LD2-35-A12125-ED-UNV-RSW LITHONIA SPECTRA-SF DAY-BRITE LINCS 1 NO UNIV. 51 WATTS MCGRAW EDISON ISS-B02-LED-E1-BL2-BK-P 1 NO UNIV. 51 WATTS MCGRAW EDISON ISS-B02-LED-E1-BL3-BK-P SURE-LITE LPX-7-SD LITHONIA LQM DAY BRITE SURE-LITE CCX LPX-7-DH-SD LITHONIA LHQM DAY BRITE VCL NA NA NA NA UNIV. UNIV. 1 WATT 1 WATT P E. EXPIRES: DAY-BRITE 2 RY LUMENS COLOR TEMP. 1 LAMP QTY. REG I E DESCRIPTION LAMP TYPE L NA IO R FIXTURE NO. ED PROFES ER S T I N E S G E N 86683 ER 1. 12-31-2016 LIGHT FIXTURE SCHEDULE E-003 3 GENERAL SHEET NOTES REFERENCE KEY NOTES 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 EMAIL: info@ADWarchitect.com SHEET KEY NOTES 1. 2. 3. 4. SECURITY CAMERA SHALL BE RELOCATED. REMOVE EXISTING LIGHT. EXISTING TO REMAIN PANEL "H." EXIT SIGN SHALL BE RELOCATED. L NA IO R REG IS E D PROF ES RE S TE I N E G E N 86683 Digital Signature A IN Y 2 1 0 08, 2 RR A NJ Y M E M BE OREGON P E. EXPIRES: 12-31-2016 4 4 2 2 3 1 1 FIRST FLOOR DEMOLITION PLAN 1 FIRST FLOOR DEMOLITION PLAN SCALE: 1/8" = 1'-0" E-100 1 GENERAL SHEET NOTES 1. ALL EXIT SIGNS, NIGHT LIGHTS, AND EMERGENCY LIGHTS SHALL BE WIRED AHEAD OF ALL LOCAL SWITCHING. REFERENCE KEY NOTES 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 EMAIL: info@ADWarchitect.com SHEET KEY NOTES 1. 2. 3. 4. 5. RELOCATED EXIT SIGN. EXTEND BRANCH CIRCUIT CONDUIT AND WIRING TO NEW LOCATION. EXISTING TO REMAIN PANEL "H." EXHAUST FAN EF-1. EXHAUST FAN EF-2. ALL SWITCHES SHALL BE GANGED TOGETHER IN A SINGLE BOX AND COVERPLATE WHERE SHOWN TOGETHER ON THE PLANS (TYPICAL). L NA IO R REG IS E D PROF ES RE S TE I N E G E N 86683 Digital Signature A IN Y 2 1 0 08, 2 RR A NJ Y M E M BE OREGON P E. EXPIRES: 12-31-2016 P101 R 3 M R2 R2E NL 1 R2E NL 3 P110 M 1 2 e UC4 e UC4 e UC4 a b c d e M M M M M 3 M M D P102 D R2E R2 R2 d d UC4 R2 R2 c c R2 R2 b R2 a R2 R2 b R2 R2 c R2 a UC3 c b 5 d e UC3 R2 a b c d e UC4 e R2 M M M M M M M R2E d W2 e UC4 e UC4 e UC4 4 R2 b R2 a R2 c a c R2 b R2 a b R2 W2 P103 a W2 FIRST FLOOR LIGHTING PLAN 1 FIRST FLOOR LIGHTING PLAN SCALE: 1/8" = 1'-0" E-101 2 GENERAL SHEET NOTES REFERENCE KEY NOTES 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 EMAIL: info@ADWarchitect.com SHEET KEY NOTES D PROF ES RE S TE I N E G E N 86683 L NA IO R Digital Signature A IN 0 08, 2 Y A NJ Y M 2 M BE OREGON 1 4. 5. 6. RR 3. E 6 EXISTING PANEL "H." LOCATE JUNCTION BOX 96" OFF WALL IN ACCESSIBLE CEILING FOR FUTURE PROJECTOR. CONDUCTORS SHALL BE LABELED AS 'FUTURE.' RECEPTACLE FOR SHORT THROW PROJECTOR MOUNTED AT 6" BELOW CEILING. RWES-AHU-1. RWES-AHU-2. TWO EXISTING 7-1/2HP HEATING WATER CIRCULATION PUMPS SHALL BE REPLACED. DISCONNECT AND RE-CONNECT EXISTING BRANCH CIRCUIT CONDUIT AND WIRING. REFERENCE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. PUMPS LOCATED IN BOILER ROOM ABOVE. REG IS E 1. 2. P E. EXPIRES: 12-31-2016 P106 1 C, GFCI C C C C, GFCI C P109 P105 C P104 C C C P108 P111 P107 C C 2 2 J J 4 C C 5 C C 3 3 P111 FIRST FLOOR POWER PLAN 1 FIRST FLOOR POWER PLAN SCALE: 1/8" = 1'-0" 2 FIRST FLOOR OVERALL PLAN SCALE: 1/16" = 1'-0" E-102 3 GENERAL SHEET NOTES 3 REFERENCE KEY NOTES 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 EMAIL: info@ADWarchitect.com SHEET KEY NOTES 1. 2. 1 3. EXISTING INTERCOM MASTER PANEL. EXISTING NETWORK PATCH PANELS, PHONE 66 BLOCK, AND SECURITY NVR PATCH PANEL. CATV HEAD END EQUIPMENT (LOCATED IN ELECTRICAL ROOM). L NA IO R REG IS E D PROF ES RE S TE I N E G E N 86683 Digital Signature A IN Y 2 1 0 08, 2 RR A NJ Y M E M BE OREGON P E. EXPIRES: 12-31-2016 2 D101 D101 S A102 R R S S A103 A101 D103 D106 C, D C, D D105 D102 D107 D104 A105 DW A104 DW FIRST FLOOR LOW VOLTAGE PLAN 1 FIRST FLOOR LOW VOLTAGE PLAN SCALE: 1/8" = 1'-0" 2 FIRST FLOOR OVERALL LOW VOLTAGE PLAN SCALE: 1/16" = 1'-0" E-103 4 GENERAL SHEET NOTES REFERENCE KEY NOTES 5 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 EMAIL: info@ADWarchitect.com SHEET KEY NOTES 2. 3. 6 4 4. 5. 6. D PROF ES RE S TE I N E G E N 86683 L NA IO R RELOCATED SECURITY CAMERA COORDINATE FINAL LOCATION WITH OWNER PRIOR TO ROUGH-IN. 24V POWER FOR MAGNETIC DOOR HOLD OPEN. EXTEND BRANCH CIRCUIT CONDUIT AND WIRING FROM EXISTING DOOR HOLD OPEN. REFERENCE OVERALL ELECTRICAL PLAN FOR LOCATION. EXISTING DOOR HOLD OPEN. EXISTING FACP. EXISTING NETWORK PATCH PANELS, PHONE 66 BLOCK, AND SECURITY NVR PATCH PANEL. REG IS E 1. Digital Signature A IN Y 2 1 0 08, 2 RR A NJ Y M E M BE OREGON P E. EXPIRES: 12-31-2016 3 3 F103 F103 2 J J 2 F101 F104 F105 15 CD 15 CD F 2 F J 15 CD J 15 CD S103 2 S101 F102 1 60 CD 60 CD 1 S102 FIRST FLOOR FIRE ALARM & SECURITY PLAN 1 FIRST FLOOR FIRE ALARM & SECURITY PLAN SCALE: 1/8" = 1'-0" 2 FIRST FLOOR OVERALL FIRE ALARM & SECURITY PLAN SCALE: 1/16" = 1'-0" E-104 5 GENERAL SHEET NOTES POWER CONDUIT / CONDUCTOR SCHEDULE GROUND CABLE SPARE P101 1 .75 INCH 1- #10 1- #10 1- #10 - P102 1 .75 INCH 1- #10 1- #10 1- #10 P103 1 .75 INCH 1- #10 1- #10 P104 1 .75 INCH 1 - #12 P105 1 .75 INCH 1 - #12 FROM TO DESCRIPTION SHEET KEY NOTE - PANEL H CIRCUIT #27 RM. 187, 188, 188A LIGHTS - - - PANEL H CIRCUIT #29 RM. 186, 186A LIGHTS - 1- #10 - - EXISTING EXTERIOR LUMIANIRES NEW LUMINAIRE EXISTING EXTERIOR LIGHT CIRCUIT NOTE #1 1 - #12 1 - #12 - - PANEL H CIRCUIT #31 RM. 188 RECEPTACLES - 1 - #12 1 - #12 - - PANEL H CIRCUIT #33 RM. 186 RECEPTACLES - P106 1 .75 INCH 1 - #12 1 - #12 1 - #12 - - PANEL H CIRCUIT #39 RM. 186, 187, 188 RECEPTACLES P107 1 .75 INCH 3 - #10 - 1 - #10 - - PANEL H CIRCUIT #28, 30, 32 RWES-AHU-1 - P108 1 .75 INCH 3 - #10 - 1 - #10 - - PANEL H CIRCUIT #34, 36, 38 RWES-AHU-2 - P109 1 .75 INCH 1 - #12 1 - #12 1 - #12 - - PANEL H CIRCUIT #41 RM. 186, 188 RECEPTACLES - P110 1 - 3 - #14 - - - - POWER PACK OCCUPANCY SENSORS LOW VOLTAGE CONTROL WIRING - P111 1 .75 INCH 1 - #12 1 - #12 1 - #12 - - PANEL H CIRCUIT #7 RWES-RTU-1, RWES-RTU-2 RECEPTACLES - REFERENCE KEY NOTES EMAIL: info@ADWarchitect.com SHEET KEY NOTES 1. 2. 3. 4. DATA CONDUIT / CONDUCTOR SCHEDULE CONDUITS CONDUCTORS PER CONDUIT CABLE SPARE D101 2 2 INCH - - - - D102 1 .75 INCH - - - D103 1 .75 INCH - - D104 1 .75 INCH - - FROM TO DESCRIPTION SHEET KEY NOTE - NEW ADDITION EXISTING CORRIDOR CONDUIT STUB THROUGH FIRE WALL - 1 - CAT6A - EXISTING NETWORK PATCH PANEL CLASSROOM 188 TYPE WAP OUTLET NOTE #6 - 1 - CAT6A - EXISTING NETWORK PATCH PANEL CLASSROOM 188 TYPE D OUTLET NOTE #6 - 2 - CAT6A - EXISTING NETWORK PATCH PANEL & EXISTING TELEPHONE 66 BLOCK CLASSROOM 188 TYPE DW OUTLET NOTE #6 D105 1 .75 INCH - - - 1 - CAT6A - EXISTING NETWORK PATCH PANEL CLASSROOM 186 TYPE WAP OUTLET NOTE #6 D106 1 .75 INCH - - - 1 - CAT6A - EXISTING NETWORK PATCH PANEL CLASSROOM 186 TYPE D OUTLET NOTE #6 D107 1 .75 INCH - - - 2 - CAT6A - EXISTING NETWORK PATCH PANEL & EXISTING TELEPHONE 66 BLOCK CLASSROOM 186 TYPE DW OUTLET NOTE #6 D108 - - - - - - - - - - - D109 - - - - - - - - - - - D110 - - - - - - - - - - - 5. 6. 7. D PROF ES RE S TE I N E G E N 86683 L NA IO R GROUND Digital Signature OREGON Y M A NEUTRAL A POWER NJ SIZE M QUANTITY EXTEND EXISTING BRANCH CIRCUIT CONDUIT AND WIRING MADE AVAILABLE DURING DEMOLITION TO NEW DEVICE / FIXTURE. NOT USED. NOT USED. INSTALL CABLE IN CEILING SPACE OF ROOM WITH MASTER INTERCOM PANEL. PROVIDE 12 FEET OF SLACK AND COIL SLACK IN CEILING. TERMINATIONS SHALL BE BY OWNER. COORDINATE LOCATION OF EXISTING INTERCOM SPEAKER AND CIRCUIT WITH OWNER. TERMINATE AS DIRECTED BY OWNER. TERMINATE HORIZONTAL CABLE AS DIRECTED BY OWNER. INTERCEPT AND EXTEND EXISTING FIRE ALARM CIRCUIT AS DIRECTED BY OWNER. BE CONDUIT ID. NO. 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 IN 0 08, 2 Y NEUTRAL 2 POWER 1 SIZE RR QUANTITY E CONDUCTORS PER CONDUIT REG IS E CONDUITS CONDUIT ID. NO. P E. EXPIRES: 12-31-2016 AUDIO / VISUAL CONDUIT / CONDUCTOR SCHEDULE CONDUITS CONDUCTORS PER CONDUIT CONDUIT ID. NO. QUANTITY SIZE POWER NEUTRAL GROUND CABLE SPARE A101 1 .75 INCH - - - (1) 22/4 A102 - - - - A103 1 .75 INCH - - A104 1 1 INCH - A105 1 1 INCH A106 - A107 FROM TO DESCRIPTION SHEET KEY NOTE - INTERCOM MASTER CONTROL PANEL CLASSROOM 188 INTERCOM SPEAKER & PAGING STATION INTERCOM HOME RUN NOTE #4 (1) 22/4 - EXISTING CORRIDOR INTERCOM SPEAKER HALL 187 PAGING SPEAKER INTERCOM CIRCUIT NOTE #5 - (1) 22/4 - INTERCOM MASTER CONTROL PANEL CLASSROOM 186 INTERCOM SPEAKER & PAGING STATION INTERCOM HOME RUN NOTE #4 - - 1 - COAX - CLASSROOM 188 CATV OUTLET CATV HEAD END EQUIPMENT CATV HOMERUN NOTE #6 - - - 1 - COAX - CLASSROOM 186 CATV OUTLET CATV HEAD END EQUIPMENT CATV HOMERUN NOTE #6 - - - - - - - - - - - - - - - - - - - - - A108 - - - - - - - - - - - A109 - - - - - - - - - - - A110 - - - - - - - - - - - SECURITY CONDUIT / CONDUCTOR SCHEDULE CONDUITS CONDUCTORS PER CONDUIT CONDUIT ID. NO. QUANTITY SIZE POWER NEUTRAL GROUND CABLE SPARE S101 1 .75 INCH - - - 1-CAT6A S102 1 .75 INCH - - - S103 1 .75 INCH - - S104 - - - S105 - - - FROM TO DESCRIPTION SHEET KEY NOTE - EXISTING NETWORK PATCH PANEL EXTERIOR CAMERA CAMERA NOTE #6 1-CAT6A - EXISTING NETWORK PATCH PANEL EXTERIOR CAMERA CAMERA NOTE #6 - 1-CAT6A - EXISTING NETWORK PATCH PANEL EXTERIOR CAMERA CAMERA NOTE #6 - - - - - - - - - - - - - - - - FIRE ALARM CONDUIT / CONDUCTOR SCHEDULE CONDUITS CONDUCTORS PER CONDUIT CONDUIT ID. NO. QUANTITY SIZE POWER NEUTRAL GROUND CABLE SPARE F101 1 .75 INCH - - - (1) NAC F102 1 .75 INCH - - - F103 1 .75 INCH - - F104 1 .75 INCH - F105 1 .75 INCH - FROM TO DESCRIPTION SHEET KEY NOTE - EXISTING NAC CIRCUIT NEW NOTIFICATION DEVICES NOTIFICATION CIRCUIT NOTE #7 (1) NAC - EXISTING NAC CIRCUIT NEW NOTIFICATION DEVICES NOTIFICATION CIRCUIT NOTE #7 - (1) 18/2 - EXISTING NAC DOOR HOLD OPEN NEW DOOR HOLD OPEN DOOR HOLD OPEN CIRCUIT NOTE #7 - - (1) IDC - EXISTING IDC CIRCUIT NEW INITIATION DEVICES INITIATING DEVICE CIRCUIT NOTE #7 - - (1) IDC - EXISTING IDC CIRCUIT NEW INITIATION DEVICES INITIATING DEVICE CIRCUIT NOTE #7 ELECTRICAL SCHEDULES 1 ELECTRICAL SCHEDULES SCALE: N/A E-601 6 GENERAL SHEET NOTES 1. NEW CIRCUITS IN EXISTING PANELS ARE IN BOLD TEXT AND HIGHLIGHTED GREY. REFERENCE KEY NOTES 518 Washington St. Suite 4 P. O. Box 1348 Ashland, Oregon 97520 TEL: (541)488-0719 EMAIL: info@ADWarchitect.com SHEET KEY NOTES 1. 2. 3. PROVIDE NEW CIRCUIT BREAKER IN EXISTING SPACE. EXISTING CONNECTED LOAD IS ESTIMATED AT 17.3 KW, 48 AMPS. DISCONNECT EXISTING BRANCH CIRCUIT FROM POLES #36 AND #38. RELOCATE TO POLES #40 AND #42. L NA IO R REG IS E D PROF ES RE S TE I N E G E N 86683 Digital Signature A IN Y 2 1 0 08, 2 RR A NJ Y M E M BE 2 OREGON P E. EXPIRES: 12-31-2016 3 1 1 1 3 PANEL SCHEDULES E-610 7