DEVICE SYMBOL LEGEND
DESCRIPTION
HOMERUN TO PANELBOARD. NUMBER OF
ARROWS INDICATES NUMBER OF CIRCUITS.
(EXAMPLE: HOMERUN TO PANEL L211 CKTS.
#1 AND #3.)
L211-1,3
BFG
BLDG
BELOW FINISHED GRADE
BUILDING
C
CB
CKT
CR
CONDUIT
CIRCUIT BREAKER
CIRCUIT
CONTROL RELAY
CONDUIT DOWN
DIRECT CURRENT
DRAWING
CONDUIT, STUBBED AND CAPPED AS SHOWN
DC
DWG
SYMBOL
xxA
CONDUIT UP
xxA
DIRECT CONNECTION TO EQUIPMENT.
HAND HOLE
HORSEPOWER
JB
JUNCTION BOX
KCMIL
KS
KVA
KW
THOUSAND CIRCULAR MILS
KEY SWITCH
KILOVOLT-AMPERE
KILOWATT
LED
LS
LV
LIGHT EMITTING DIODE
LIMIT SWITCH
LOW VOLTAGE
MH
MLO
MS
MAN HOLE
MAIN LUGS ONLY
MOTION SENSOR
N
N/A
NC
NEC
NEX
NEUTRAL
NOT APPLICABLE
NORMALLY CLOSED
NATIONAL ELECTRICAL CODE
REPLACE EXISTING WIRING DEVICE AND FACEPLATE WITH
NEW. BACK BOX AND CONDUIT SHALL REMAIN.
NL
NO
NTS
NIGHT LIGHT
NORMALLY OPEN
NOT TO SCALE
OC
OEM
ON CENTER
ORIGINAL EQUIPMENT MANUFACTURER
FLEXIBLE CONDUIT CONNECTION TO
EQUIPMENT.
ADA DOOR PUSH PLATE.
PANELBOARD
CEILING MOUNTED HEAT DETECTOR.
MAGNETIC STARTER AND FUSED
DISCONNECT SWITCH, STARTER SIZE AND
FUSE SIZE AS INDICATED.
CIRCUIT BREAKER SWITCH.
X
LUMINAIRE, RECESSED OR SURFACE
MOUNTED, AS INDICATED ON DRAWINGS.
FIRE ALARM VISUAL ONLY STROBE, TOP OF
LENS MOUNTED AT 96" AFF UNLESS
OTHERWISE NOTED.
FS
TR
T
FIRE ALARM HORN STROBE, TOP OF LENS
MOUNTED AT 96" AFF UNLESS OTHERWISE
NOTED.
SWITCH, SINGLE POLE, MOUNTED AT 42" AFF
TO CENTER UNLESS OTHERWISE NOTED.
3 - THREE WAY
M - MOTOR RATED TOGGLE SWITCH
F
Z
LUMINAIRE, RECESSED, WIRED FOR
MULTILEVEL CONTROL.
P
PHOTOCELL.
M
MOTION SENSOR, WALL MOUNTED,
MOUNTED AT 42" AFF TO CENTER UNLESS
OTHERWISE NOTED.\
M = MULTI-LEVEL SWITCH
M
MOTION SENSOR, CEILING MOUNTED.
R
CEILING MOUNTED LOW VOLTAGE POWER
PACK FOR CEILING MOUNTED MOTION
SENSOR.
LUMINAIRE, RECESSED, WITH EMERGENCY
BATTERY PACK AND BALLAST.
LUMINAIRE, RECESSED OR PENDENT
MOUNTED AS INDICATED ON DRAWINGS
WALL WASH LUMINAIRE, RECESSED.
EXIT SIGN, SINGLE FACE CEILING MOUNTED
WITH CHEVRONS AS INDICATED ON
DRAWINGS.
CIRCUIT BREAKER
ED PROFES
ER
S
T
I N E
S
G
E
N
86683
Digital Signature
FIRE ALARM PULL STATION, MOUNTED AT
42" AFF UNLESS OTHERWISE NOTED.
FS
TR
T
CIRCUIT BREAKER, ENCLOSED
OREGON
Y
M
IN
0
08, 2
P
E.
EXPIRES:
12-31-2016
RELAY MODULE.
M
UTILITY METER & CURRENT TRANSFORMERS
ST
SHUNT TRIP
GROUND
COMBINATION POWER/DATA FLOORBOX.
EXIT SIGN,TWO FACES, CEILING MOUNTED
WITH CHEVRONS AS INDICATED ON
DRAWINGS.
ELECTRICAL CONNECTION
AUDIO / VISUAL FLOORBOX.
EXIT SIGN, SINGLE FACE, WALL MOUNTED
WITH CHEVRONS AS INDICATED ON
DRAWINGS.
LUMINAIRE, WALL SCONCE.
WALL MOUNTED SECURITY CAMERA.
LUMINAIRE, WALL MOUNTED.
LOW VOLTAGE DATA OUTLET, MOUNTED AT
18" AFF UNLESS OTHERWISE NOTED.
PROVIDE 1" CONDUIT WITH BUSHING FROM
BOX TO NEAREST AVAILABLE CEILING
SPACE. PROVIDE BUSHING. REFERENCE
DETAILS ON THIS SHEET FOR TYPE DETAILS.
C - MOUNTED 6" ABOVE COUNTER
LUMINAIRE, TRACK LIGHTING.
PHASE
PB
PE
PNL
XXX
DISCONNECT SWITCH, UN-FUSED TYPE, SIZE
AS INDICATED ON DRAWINGS. "xxA"
INDICATES AMPERAGE.
CONDUIT AND CONDUCTORS INSTALLED
BELOW GRADE, BELOW SLAB, OR
CONCEALED.
WIRE, CONTINUED.
HH
HP
DUCT SMOKE DETECTOR WITH REMOTE
ALARM
TRANSFORMER
L
NA
IO
R
GRAFIK EYE
GROUND FAULT CIRCUIT INTERRUPTER
GROUND
RECEPTACLE, CEILING MOUNTED
EMAIL: info@ADWarchitect.com
A
GE
GFCI
GND
CEILING MOUNTED SMOKE DETECTOR.
DESCRIPTION
A
FULL LOAD AMPERES
RECEPTACLE, TAMPER PROOF
SYMBOL
NJ
FLA
DESCRIPTION
M
ELECTRICAL METALLIC TUBING
EXISTING DEVICE SHALL REMAIN
SYMBOL
BE
EMT
ETR
DESCRIPTION
2
RY
SYMBOL
ONE LINE DIAGRAM SYMBOL LEGEND
1
AMPERE
AMPERE FRAME
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AMPERE TRIP
AMERICAN WIRE GAUGE
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
ER
A
AF
AFF
AFG
AT
AWG
ELECTRICAL INDICATOR SYMBOLS
REG
I
E
ELECTRICAL ABBREVIATIONS
JUNCTION BOX, xx INDICATES IDENTIFIER
IF ANY
PULL BOX, PANIC BUTTON, PUSH BUTTON
PHOTE EYE
PANEL
MOTOR / EXHAUST FAN.
QS
LUTRON QS MODULE
REX
REMOVE EXISTING DEVICE / EQUIPMENT
SW
SWBD
SWITCH
SWITCHBOARD
TYP
TYPICAL
UG
UNO
UNDERGROUND
UNLESS NOTED OTHERWISE
VA
VDC
VOLT-AMPERE
VOLTS DIRECT CURRENT
W
WP
WS
WATT, WIRE
WEATHERPROOF
LUTRON LOW VOLTAGE WALL SWITCH
XFMR
TRANSFORMER
Y
WYE
+72
MOUNTING UNITS EXPRESSED IN
INCHES TO CENTERLINE ABOVE
FINISHED FLOOR OR GRADE.
ONE POLE
TWO POLE
THREE POLE
FOUR POLE
1P
2P
3P
4P
CEILING MOUNTED LOW VOLTAGE OUTLET.
REFERENCE DETAILS ON THIS SHEET FOR
TYPE DETAILS.
RECEPTACLE, NEMA CONFIGURATION AS
INDICATED ON THE DRAWINGS, MOUNTED
AT 18" AFF UNLESS OTHERWISE NOTED.
RECEPTACLE, SINGLE OUTLET, MOUNTED
AT 18" AFF UNLESS OTHERWISE NOTED.
X
X
X
GFCI RECEPTACLE, DUPLEX, MOUNTED AT
18" AFF TO CENTER UNLESS OTHERWISE
NOTED.
C - MOUNTED HORIZONTALLY 6"
ABOVE COUNTER
WP - WEATHERPROOF
RECEPTACLE, DUPLEX, MOUNTED AT 18"
AFF TO CENTER UNLESS OTHERWISE
NOTED.
C - MOUNTED HORIZONTALLY 6"
ABOVE COUNTER.
PNT - PRINTER, VERIFY HEIGHT WITH
ARCHITECT
TV - TELEVISION, VERIFY HEIGHT
WITH ARCHITECT.
UCR - UNDERCABINET
REFRIGERATOR
WP - WEATHER PROOF
XX" - DIMENSIONED HEIGHT
R
CATV COAX OUTLET, SINGLE F TYPE
CONNECTOR, MOUNTED AT 18" AFF UNLESS
OTHERWISE NOTED. P. PROVIDE 1"
CONDUIT WITH BUSHING FROM BOX TO
NEAREST AVAILABLE CEILING SPACE.
PAGING / INTERCOM HANDSET OUTLET,
MOUNTED AT 42" AFF UNLESS OTHERWISE
NOTED. PROVIDE 1" CONDUIT WITH
BUSHING FROM BOX TO NEAREST
AVAILABLE CEILING SPACE.
CEILING MOUNTED WIRELESS ACCESS
POINT.
S
CEILING MOUNTED INTERCOM SPEAKER
BRANCH CIRCUIT PANELBOARD
ELECTRICAL SYMBOL
LEGEND,
ABBREVIATIONS &
INDICATORS
E-001
1
GENERAL SHEET NOTES
272005.W01
272005.W01
REFERENCE KEY NOTES
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
EMAIL: info@ADWarchitect.com
272005.J45
272005.J45
272005.J11
SHEET KEY NOTES
1.
272005.J45
xxx.
272005.J11
REG
I
E
L
NA
IO
R
ED PROFES
ER
S
T
I N E
S
G
E
N
86683
SCALE: N/A
IN
1
0
08, 2
P
E.
EXPIRES:
TYPE IDENTIFICATION
ER
3
M
A
COMBINATION POWER/DATA FLOORBOX SUBPLATE DETAIL
Y
A
NJ
TYPE IDENTIFICATION
SCALE: N/A
OREGON
M
2
SCALE: N/A
TYPE WD FACEPLATE
BE
1
TYPE D FACEPLATE
2
RY
Digital Signature
12-31-2016
TYPE IDENTIFICATION
TYPE D:
TYPE
:
ONE JACK, FACEPLATE MOUNTED AT 18"
AFF, UON.
ONE JACK, FACEPLATE MOUNTED IN
CEILING. FACEPLATE SHALL BE
STAINLESS STEEL.
TYPE WD: TWO JACKS, FACEPLATE MOUNTED AT 18"
AFF, UON.
TYPE
:
TWO DUPLEXES, ONE RJ45, ONE RJ11.
ELECTRICAL EQUIPMENT NAMEPLATE SCHEDULE
ITEM
NAME PLATE DESCRIPTION
1-1/2" NPT
1
2
PANEL H
PANEL H2
NAMEPLATE /
TAG
Dwg.
SYMBOL
Dwg.
REF.
NAMEPLATE
H
HLES E-102
NAMEPLATE
H2
HLES E-102
3
FUSED DISCONNECT SWITCH
FDS-PC-1
NAMEPLATE
FDS-PC-1
HLES E-102
4
FUSED DISCONNECT SWITCH
FDS-PC-2
NAMEPLATE
FDS-PC-2
HLES E-102
5
PHASE CONVERTER
PC-1
NAMEPLATE
PC-1
HLES E-102
6
PHASE CONVERTER
PC-2
NAMEPLATE
PC-2
HLES E-102
NAMEPLATE
H
PSES E-102
NAMEPLATE
H
RSES E-102
COMMENTS
3/4" NPT
4
AUDIO / VISUAL FLOORBOX DETAIL
7
SCALE: N/A
TYPE IDENTIFICATION
TYPE
:
8
PANEL H
PANEL G2
ONE 3 4" C FLEXIBLE CONNECTION FOR INTERCOM WIRING.
ELECTRICAL DETAILS
& NAMEPLATE
SCHEDULE
E-002
2
GENERAL SHEET NOTES
REFERENCE KEY NOTES
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
EMAIL: info@ADWarchitect.com
SHEET KEY NOTES
xxx.
LED LIGHT FIXTURE SCHEDULE
DRIVER /
BALLAST
DRIVER /
BALLAST
QTY.
EMERGENCY
DRIVER / BALLAST
VOLTS
LOAD
MFR.
3500K
M
A
1500 LM
Y
A
NA
NJ
LED
STANDARD
0-10V
1
NO
UNIV.
23 WATTS
GOTHAM
ICO-35-15-4
OREGON
M
D
RECESSED OPEN 6" DIAMETER, 6" HIGH DOWNLIGHT, WIDE BEAM DISTRIBUTION, 80CRI, DIE-CAST ALUMINUM
HOUSING, SELF-FLANGED SEMI-SPECULAR REFLECTOR, WHITE FLANGE, AND WET LOCATION LISTED.
LD6A-15-D010TE-ERW6A15-8-35-6LW
1-H-WF
Digital Signature
BE
PORTFOLIO
MODEL NUMBER
IN
0
08, 2
DE
FIXTURE SHALL BE SIMILAR TO TYPE 'D' EXCEPT WIRED TO LOCAL EMERGENCY INVERTER.
R2
FLUORESCENT 2' x 4' X 3.25"H RECESSED LUMINAIRE WITH COLD ROLLED STEEL HOUSING, ACRYLIC PRISMATIC LENS
(#12 PATTERN), FLAT WHITE STEEL DOOR, WHITE ENAMEL FINISH, AND SUITABLE FOR DAMP LOCATIONS. FIXTURE
SHALL BE USED IN BOTH LAY-IN AND DRYWALL CEILINGS. CONTRACTOR SHALL VERIFY TRIM TYPE REQUIRED.
R2E
R2S
UC3
UC4
W2
W3
X
X2
T8
FLUORESCENT 2' x 4' X 3.25"H RECESSED LUMINAIRE WITH COLD ROLLED STEEL HOUSING, ACRYLIC PRISMATIC LENS
(#12 PATTERN), FLAT WHITE STEEL DOOR, WHITE ENAMEL FINISH PAINTED AFTER FABRICATION, AND SUITABLE FOR
DAMP LOCATIONS. FIXTURE SHALL BE USED IN BOTH LAY-IN AND DRYWALL CEILINGS. CONTRACTOR SHALL VERIFY
TRIM TYPE REQUIRED.
T8
FLUORESCENT 2' x 4' X 4"H SURFACE MOUNTED LUMINAIRE WITH COLD ROLLED STEEL HOUSING, ACRYLIC PRISMATIC
LENS (#12 PATTERN), FLAT WHITE STEEL DOOR, WHITE ENAMEL FINISH, AND SUITABLE FOR DAMP LOCATIONS.
T8
3' X 4.5" UNDERCABINET MOUNTED LED FIXTURE WITH STEEL HOUSING, INTEGRAL ROCKER-STYLE SWITCHAND WHITE
FINISH. FIXTURE SHALL BE CONTINUOUSLY MOUNTED WHERE SHOWN ON THE DRAWINGS.
4' X 4.5" UNDERCABINET MOUNTED LED FIXTURE WITH STEEL HOUSING, INTEGRAL ROCKER-STYLE SWITCH, AND WHITE
FINISH. FIXTURE SHALL BE CONTINUOUSLY MOUNTED WHERE SHOWN ON THE DRAWINGS.
18' DIAMETER x 12" DEEP x 9"H QUARTER SPHERE WALL MOUNTED LUMINAIRE WITH DIE-CAST ALUMINUM HOUSING,
TYPE II DISTRIBUTION, BLACK FINISH, AND PUSH-BUTTON TYPE PHOTO CONTROL.
18' DIAMETER x 12" DEEP x 9"H QUARTER SPHERE WALL MOUNTED LUMINAIRE WITH DIE-CAST ALUMINUM HOUSING,
TYPE III DISTRIBUTION, BLACK FINISH, AND PUSH-BUTTON TYPE PHOTO CONTROLL .
CEILING MOUNTED EXIT SIGN, GREEN LETTERS, POLYCARBONATE HOUSING, WHITE FINISH EMERGENCY BATTERY, TEST
SWITCH / POWER INDICATOR LIGHT, SELF-DIAGNOSTICS TEST UNIT, UL 924 LISTED, AND UL DAMP LOCATION LISTED.
CEILING MOUNTED EXIT SIGN WITH TWIN EGRESS LAMPS, GREEN LETTERS, POLYCARBONATE HOUSING, WHITE FINISH
EMERGENCY BATTERY, TEST SWITCH / POWER INDICATOR LIGHT, SELF-DIAGNOSTICS TEST UNIT, UL 924 LISTED, AND UL
DAMP LOCATION LISTED.
LED
LED
2
2
2
N/A
N/A
N/A
N/A
N/A
1600 LM
2400 LM
3500K
3500K
3500K
3500K
3500K
LED
N/A
4354 LM
3000K
LED
N/A
3996 LM
3000K
LED
LED
NA
NA
NA
NA
NA
NA
ELECTRONIC
ELECTRONIC
ELECTRONIC
STANDARD
0-10V
STANDARD
0-10V
STANDARD
0-10V
STANDARD
0-10V
NA
NA
1
1
1
1
1
NO
YES
NO
NO
NO
UNIV.
UNIV.
UNIV.
UNIV.
UNIV.
53 WATTS
53 WATTS
61 WATTS
28 WATTS
37 WATTS
CALCULITE
METALUX
2-X-C8-232-A-UNV-EB8-1
LITHONIA
GT SERIES
DAY-BRITE
METALUX
TG8
2-X-C8-232-A-UNV-EL-EB8-1
LITHONIA
GT SERIES
DAY-BRITE
METALUX
TG8
2-M-2-32-A-UNV-EB8
LITHONIA
M Series
DAY-BRITE
FAIL SAFE
SMR
UCL-3-LD2-35-A12125-ED-UNV-RSW
LITHONIA
SPECTRA-SF
DAY-BRITE
FAIL SAFE
LINCS
UCL-3-LD2-35-A12125-ED-UNV-RSW
LITHONIA
SPECTRA-SF
DAY-BRITE
LINCS
1
NO
UNIV.
51 WATTS
MCGRAW EDISON
ISS-B02-LED-E1-BL2-BK-P
1
NO
UNIV.
51 WATTS
MCGRAW EDISON
ISS-B02-LED-E1-BL3-BK-P
SURE-LITE
LPX-7-SD
LITHONIA
LQM
DAY BRITE
SURE-LITE
CCX
LPX-7-DH-SD
LITHONIA
LHQM
DAY BRITE
VCL
NA
NA
NA
NA
UNIV.
UNIV.
1 WATT
1 WATT
P
E.
EXPIRES:
DAY-BRITE
2
RY
LUMENS
COLOR
TEMP.
1
LAMP
QTY.
REG
I
E
DESCRIPTION
LAMP
TYPE
L
NA
IO
R
FIXTURE
NO.
ED PROFES
ER
S
T
I N E
S
G
E
N
86683
ER
1.
12-31-2016
LIGHT FIXTURE
SCHEDULE
E-003
3
GENERAL SHEET NOTES
REFERENCE KEY NOTES
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
EMAIL: info@ADWarchitect.com
SHEET KEY NOTES
1.
2.
3.
4.
SECURITY CAMERA SHALL BE
RELOCATED.
REMOVE EXISTING LIGHT.
EXISTING TO REMAIN PANEL "H."
EXIT SIGN SHALL BE RELOCATED.
L
NA
IO
R
REG
IS
E
D PROF ES
RE
S
TE
I N E
G
E
N
86683
Digital Signature
A
IN
Y
2
1
0
08, 2
RR
A
NJ
Y
M
E
M
BE
OREGON
P
E.
EXPIRES:
12-31-2016
4
4
2
2
3
1
1
FIRST FLOOR
DEMOLITION
PLAN
1
FIRST FLOOR DEMOLITION PLAN
SCALE: 1/8" = 1'-0"
E-100
1
GENERAL SHEET NOTES
1.
ALL EXIT SIGNS, NIGHT LIGHTS, AND
EMERGENCY LIGHTS SHALL BE WIRED
AHEAD OF ALL LOCAL SWITCHING.
REFERENCE KEY NOTES
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
EMAIL: info@ADWarchitect.com
SHEET KEY NOTES
1.
2.
3.
4.
5.
RELOCATED EXIT SIGN. EXTEND
BRANCH CIRCUIT CONDUIT AND
WIRING TO NEW LOCATION.
EXISTING TO REMAIN PANEL "H."
EXHAUST FAN EF-1.
EXHAUST FAN EF-2.
ALL SWITCHES SHALL BE GANGED
TOGETHER IN A SINGLE BOX AND
COVERPLATE WHERE SHOWN
TOGETHER ON THE PLANS (TYPICAL).
L
NA
IO
R
REG
IS
E
D PROF ES
RE
S
TE
I N E
G
E
N
86683
Digital Signature
A
IN
Y
2
1
0
08, 2
RR
A
NJ
Y
M
E
M
BE
OREGON
P
E.
EXPIRES:
12-31-2016
P101
R
3
M
R2
R2E
NL
1
R2E
NL
3
P110
M
1
2
e UC4 e UC4 e UC4
a
b
c
d
e
M
M
M
M
M
3
M
M
D
P102
D
R2E
R2
R2
d
d
UC4
R2
R2
c
c
R2
R2
b
R2
a
R2
R2
b
R2
R2
c
R2
a
UC3
c
b
5
d
e
UC3
R2
a
b
c
d
e
UC4
e
R2
M
M
M
M
M
M
M
R2E
d
W2
e UC4 e UC4 e UC4
4
R2
b
R2
a
R2
c
a
c
R2
b
R2
a
b
R2
W2
P103
a
W2
FIRST FLOOR
LIGHTING PLAN
1
FIRST FLOOR LIGHTING PLAN
SCALE: 1/8" = 1'-0"
E-101
2
GENERAL SHEET NOTES
REFERENCE KEY NOTES
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
EMAIL: info@ADWarchitect.com
SHEET KEY NOTES
D PROF ES
RE
S
TE
I N E
G
E
N
86683
L
NA
IO
R
Digital Signature
A
IN
0
08, 2
Y
A
NJ
Y
M
2
M
BE
OREGON
1
4.
5.
6.
RR
3.
E
6
EXISTING PANEL "H."
LOCATE JUNCTION BOX 96" OFF WALL
IN ACCESSIBLE CEILING FOR FUTURE
PROJECTOR. CONDUCTORS SHALL
BE LABELED AS 'FUTURE.'
RECEPTACLE FOR SHORT THROW
PROJECTOR MOUNTED AT 6" BELOW
CEILING.
RWES-AHU-1.
RWES-AHU-2.
TWO EXISTING 7-1/2HP HEATING
WATER CIRCULATION PUMPS SHALL
BE REPLACED. DISCONNECT AND
RE-CONNECT EXISTING BRANCH
CIRCUIT CONDUIT AND WIRING.
REFERENCE MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION.
PUMPS LOCATED IN BOILER ROOM
ABOVE.
REG
IS
E
1.
2.
P
E.
EXPIRES:
12-31-2016
P106
1
C, GFCI
C
C
C
C, GFCI
C
P109
P105
C
P104
C
C
C
P108
P111 P107
C
C
2
2
J
J
4
C
C
5
C
C
3
3
P111
FIRST FLOOR
POWER PLAN
1
FIRST FLOOR POWER PLAN
SCALE: 1/8" = 1'-0"
2
FIRST FLOOR OVERALL PLAN
SCALE: 1/16" = 1'-0"
E-102
3
GENERAL SHEET NOTES
3
REFERENCE KEY NOTES
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
EMAIL: info@ADWarchitect.com
SHEET KEY NOTES
1.
2.
1
3.
EXISTING INTERCOM MASTER PANEL.
EXISTING NETWORK PATCH PANELS,
PHONE 66 BLOCK, AND SECURITY NVR
PATCH PANEL.
CATV HEAD END EQUIPMENT
(LOCATED IN ELECTRICAL ROOM).
L
NA
IO
R
REG
IS
E
D PROF ES
RE
S
TE
I N E
G
E
N
86683
Digital Signature
A
IN
Y
2
1
0
08, 2
RR
A
NJ
Y
M
E
M
BE
OREGON
P
E.
EXPIRES:
12-31-2016
2
D101
D101
S
A102
R
R
S
S
A103
A101
D103
D106
C, D
C, D
D105
D102
D107
D104
A105
DW
A104
DW
FIRST FLOOR
LOW VOLTAGE
PLAN
1
FIRST FLOOR LOW VOLTAGE PLAN
SCALE: 1/8" = 1'-0"
2
FIRST FLOOR OVERALL LOW VOLTAGE PLAN
SCALE: 1/16" = 1'-0"
E-103
4
GENERAL SHEET NOTES
REFERENCE KEY NOTES
5
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
EMAIL: info@ADWarchitect.com
SHEET KEY NOTES
2.
3.
6
4
4.
5.
6.
D PROF ES
RE
S
TE
I N E
G
E
N
86683
L
NA
IO
R
RELOCATED SECURITY CAMERA COORDINATE FINAL LOCATION WITH
OWNER PRIOR TO ROUGH-IN.
24V POWER FOR MAGNETIC DOOR
HOLD OPEN.
EXTEND BRANCH CIRCUIT CONDUIT
AND WIRING FROM EXISTING DOOR
HOLD OPEN. REFERENCE OVERALL
ELECTRICAL PLAN FOR LOCATION.
EXISTING DOOR HOLD OPEN.
EXISTING FACP.
EXISTING NETWORK PATCH PANELS,
PHONE 66 BLOCK, AND SECURITY NVR
PATCH PANEL.
REG
IS
E
1.
Digital Signature
A
IN
Y
2
1
0
08, 2
RR
A
NJ
Y
M
E
M
BE
OREGON
P
E.
EXPIRES:
12-31-2016
3
3
F103
F103
2
J
J
2
F101
F104
F105
15 CD
15 CD
F
2
F
J
15 CD
J
15 CD
S103
2
S101
F102
1
60 CD
60 CD
1
S102
FIRST FLOOR FIRE ALARM
& SECURITY PLAN
1
FIRST FLOOR FIRE ALARM & SECURITY PLAN
SCALE: 1/8" = 1'-0"
2
FIRST FLOOR OVERALL
FIRE ALARM & SECURITY PLAN
SCALE: 1/16" = 1'-0"
E-104
5
GENERAL SHEET NOTES
POWER CONDUIT / CONDUCTOR SCHEDULE
GROUND
CABLE
SPARE
P101
1
.75 INCH
1- #10
1- #10
1- #10
-
P102
1
.75 INCH
1- #10
1- #10
1- #10
P103
1
.75 INCH
1- #10
1- #10
P104
1
.75 INCH
1 - #12
P105
1
.75 INCH
1 - #12
FROM
TO
DESCRIPTION
SHEET KEY NOTE
-
PANEL H
CIRCUIT #27
RM. 187, 188, 188A LIGHTS
-
-
-
PANEL H
CIRCUIT #29
RM. 186, 186A LIGHTS
-
1- #10
-
-
EXISTING EXTERIOR LUMIANIRES
NEW LUMINAIRE
EXISTING EXTERIOR LIGHT CIRCUIT
NOTE #1
1 - #12
1 - #12
-
-
PANEL H
CIRCUIT #31
RM. 188 RECEPTACLES
-
1 - #12
1 - #12
-
-
PANEL H
CIRCUIT #33
RM. 186 RECEPTACLES
-
P106
1
.75 INCH
1 - #12
1 - #12
1 - #12
-
-
PANEL H
CIRCUIT #39
RM. 186, 187, 188 RECEPTACLES
P107
1
.75 INCH
3 - #10
-
1 - #10
-
-
PANEL H
CIRCUIT #28, 30, 32
RWES-AHU-1
-
P108
1
.75 INCH
3 - #10
-
1 - #10
-
-
PANEL H
CIRCUIT #34, 36, 38
RWES-AHU-2
-
P109
1
.75 INCH
1 - #12
1 - #12
1 - #12
-
-
PANEL H
CIRCUIT #41
RM. 186, 188 RECEPTACLES
-
P110
1
-
3 - #14
-
-
-
-
POWER PACK
OCCUPANCY SENSORS
LOW VOLTAGE CONTROL WIRING
-
P111
1
.75 INCH
1 - #12
1 - #12
1 - #12
-
-
PANEL H
CIRCUIT #7
RWES-RTU-1, RWES-RTU-2 RECEPTACLES
-
REFERENCE KEY NOTES
EMAIL: info@ADWarchitect.com
SHEET KEY NOTES
1.
2.
3.
4.
DATA CONDUIT / CONDUCTOR SCHEDULE
CONDUITS
CONDUCTORS PER CONDUIT
CABLE
SPARE
D101
2
2 INCH
-
-
-
-
D102
1
.75 INCH
-
-
-
D103
1
.75 INCH
-
-
D104
1
.75 INCH
-
-
FROM
TO
DESCRIPTION
SHEET KEY NOTE
-
NEW ADDITION
EXISTING CORRIDOR
CONDUIT STUB THROUGH FIRE WALL
-
1 - CAT6A
-
EXISTING NETWORK PATCH PANEL
CLASSROOM 188
TYPE WAP OUTLET
NOTE #6
-
1 - CAT6A
-
EXISTING NETWORK PATCH PANEL
CLASSROOM 188
TYPE D OUTLET
NOTE #6
-
2 - CAT6A
-
EXISTING NETWORK PATCH PANEL &
EXISTING TELEPHONE 66 BLOCK
CLASSROOM 188
TYPE DW OUTLET
NOTE #6
D105
1
.75 INCH
-
-
-
1 - CAT6A
-
EXISTING NETWORK PATCH PANEL
CLASSROOM 186
TYPE WAP OUTLET
NOTE #6
D106
1
.75 INCH
-
-
-
1 - CAT6A
-
EXISTING NETWORK PATCH PANEL
CLASSROOM 186
TYPE D OUTLET
NOTE #6
D107
1
.75 INCH
-
-
-
2 - CAT6A
-
EXISTING NETWORK PATCH PANEL &
EXISTING TELEPHONE 66 BLOCK
CLASSROOM 186
TYPE DW OUTLET
NOTE #6
D108
-
-
-
-
-
-
-
-
-
-
-
D109
-
-
-
-
-
-
-
-
-
-
-
D110
-
-
-
-
-
-
-
-
-
-
-
5.
6.
7.
D PROF ES
RE
S
TE
I N E
G
E
N
86683
L
NA
IO
R
GROUND
Digital Signature
OREGON
Y
M
A
NEUTRAL
A
POWER
NJ
SIZE
M
QUANTITY
EXTEND EXISTING BRANCH CIRCUIT
CONDUIT AND WIRING MADE
AVAILABLE DURING DEMOLITION TO
NEW DEVICE / FIXTURE.
NOT USED.
NOT USED.
INSTALL CABLE IN CEILING SPACE OF
ROOM WITH MASTER INTERCOM
PANEL. PROVIDE 12 FEET OF SLACK
AND COIL SLACK IN CEILING.
TERMINATIONS SHALL BE BY OWNER.
COORDINATE LOCATION OF EXISTING
INTERCOM SPEAKER AND CIRCUIT
WITH OWNER. TERMINATE AS
DIRECTED BY OWNER.
TERMINATE HORIZONTAL CABLE AS
DIRECTED BY OWNER.
INTERCEPT AND EXTEND EXISTING
FIRE ALARM CIRCUIT AS DIRECTED BY
OWNER.
BE
CONDUIT ID.
NO.
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
IN
0
08, 2
Y
NEUTRAL
2
POWER
1
SIZE
RR
QUANTITY
E
CONDUCTORS PER CONDUIT
REG
IS
E
CONDUITS
CONDUIT ID.
NO.
P
E.
EXPIRES:
12-31-2016
AUDIO / VISUAL CONDUIT / CONDUCTOR SCHEDULE
CONDUITS
CONDUCTORS PER CONDUIT
CONDUIT ID.
NO.
QUANTITY
SIZE
POWER
NEUTRAL
GROUND
CABLE
SPARE
A101
1
.75 INCH
-
-
-
(1) 22/4
A102
-
-
-
-
A103
1
.75 INCH
-
-
A104
1
1 INCH
-
A105
1
1 INCH
A106
-
A107
FROM
TO
DESCRIPTION
SHEET KEY NOTE
-
INTERCOM MASTER CONTROL PANEL
CLASSROOM 188 INTERCOM SPEAKER
&
PAGING STATION
INTERCOM HOME RUN
NOTE #4
(1) 22/4
-
EXISTING CORRIDOR
INTERCOM SPEAKER
HALL 187 PAGING SPEAKER
INTERCOM CIRCUIT
NOTE #5
-
(1) 22/4
-
INTERCOM MASTER CONTROL PANEL
CLASSROOM 186 INTERCOM SPEAKER
&
PAGING STATION
INTERCOM HOME RUN
NOTE #4
-
-
1 - COAX
-
CLASSROOM 188
CATV OUTLET
CATV HEAD END EQUIPMENT
CATV HOMERUN
NOTE #6
-
-
-
1 - COAX
-
CLASSROOM 186
CATV OUTLET
CATV HEAD END EQUIPMENT
CATV HOMERUN
NOTE #6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
A108
-
-
-
-
-
-
-
-
-
-
-
A109
-
-
-
-
-
-
-
-
-
-
-
A110
-
-
-
-
-
-
-
-
-
-
-
SECURITY CONDUIT / CONDUCTOR SCHEDULE
CONDUITS
CONDUCTORS PER CONDUIT
CONDUIT ID.
NO.
QUANTITY
SIZE
POWER
NEUTRAL
GROUND
CABLE
SPARE
S101
1
.75 INCH
-
-
-
1-CAT6A
S102
1
.75 INCH
-
-
-
S103
1
.75 INCH
-
-
S104
-
-
-
S105
-
-
-
FROM
TO
DESCRIPTION
SHEET KEY NOTE
-
EXISTING NETWORK PATCH PANEL
EXTERIOR CAMERA
CAMERA
NOTE #6
1-CAT6A
-
EXISTING NETWORK PATCH PANEL
EXTERIOR CAMERA
CAMERA
NOTE #6
-
1-CAT6A
-
EXISTING NETWORK PATCH PANEL
EXTERIOR CAMERA
CAMERA
NOTE #6
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
FIRE ALARM CONDUIT / CONDUCTOR SCHEDULE
CONDUITS
CONDUCTORS PER CONDUIT
CONDUIT ID.
NO.
QUANTITY
SIZE
POWER
NEUTRAL
GROUND
CABLE
SPARE
F101
1
.75 INCH
-
-
-
(1) NAC
F102
1
.75 INCH
-
-
-
F103
1
.75 INCH
-
-
F104
1
.75 INCH
-
F105
1
.75 INCH
-
FROM
TO
DESCRIPTION
SHEET KEY NOTE
-
EXISTING NAC CIRCUIT
NEW NOTIFICATION DEVICES
NOTIFICATION CIRCUIT
NOTE #7
(1) NAC
-
EXISTING NAC CIRCUIT
NEW NOTIFICATION DEVICES
NOTIFICATION CIRCUIT
NOTE #7
-
(1) 18/2
-
EXISTING NAC DOOR HOLD OPEN
NEW DOOR HOLD OPEN
DOOR HOLD OPEN CIRCUIT
NOTE #7
-
-
(1) IDC
-
EXISTING IDC CIRCUIT
NEW INITIATION DEVICES
INITIATING DEVICE CIRCUIT
NOTE #7
-
-
(1) IDC
-
EXISTING IDC CIRCUIT
NEW INITIATION DEVICES
INITIATING DEVICE CIRCUIT
NOTE #7
ELECTRICAL
SCHEDULES
1
ELECTRICAL SCHEDULES
SCALE: N/A
E-601
6
GENERAL SHEET NOTES
1.
NEW CIRCUITS IN EXISTING PANELS
ARE IN BOLD TEXT AND HIGHLIGHTED
GREY.
REFERENCE KEY NOTES
518 Washington St. Suite 4
P. O. Box 1348
Ashland, Oregon 97520
TEL: (541)488-0719
EMAIL: info@ADWarchitect.com
SHEET KEY NOTES
1.
2.
3.
PROVIDE NEW CIRCUIT BREAKER IN
EXISTING SPACE.
EXISTING CONNECTED LOAD IS
ESTIMATED AT 17.3 KW, 48 AMPS.
DISCONNECT EXISTING BRANCH
CIRCUIT FROM POLES #36 AND #38.
RELOCATE TO POLES #40 AND #42.
L
NA
IO
R
REG
IS
E
D PROF ES
RE
S
TE
I N E
G
E
N
86683
Digital Signature
A
IN
Y
2
1
0
08, 2
RR
A
NJ
Y
M
E
M
BE
2
OREGON
P
E.
EXPIRES:
12-31-2016
3
1
1
1
3
PANEL SCHEDULES