FN SERIES FLUID COOLER

advertisement
FN SERIES FLUID COOLER
Premier Solutions
1
What would your “ideal” fluid cooler solution include?
 Lower Operating Costs
 Lower Noise Levels  Higher Reliability
 Easier to Service  Greater Flexibility
 Lower Initial Cost
2
FN Series has Solutions to Lower Your Operating
Costs!
 Energy Efficient Air Mover Choices
–
–
3
1.5 Hp 830 RPM motors with Swept Blade
.5 Hp 540 RPM motor with Swept Blade
FN Series has Solutions to Lower Your Operating
Costs!
 Energy Efficient Air Mover Choices (cont.)
–
4
Variable Speed EC Motor with Swept Blade
FN Series has Solutions to Lower Your Operating
Costs!
 Models available with Low Fluid Pressure Drop Coils
–
–
5/8” Diameter tubing
Reduced pumping power requirements
 Optional High Efficiency Coil Design
–
Optional 12 and 14 FPI coils
 Optional Fan Cycling Controls
–
–
5
FNH, FNL and FNQ models only
FNE models feature variable speed
FN Series has Solutions to Meet Your Noise
Requirements!
 Reduced Sound Air Mover Choices
–
–
–
1.5 Hp 830 RPM and .5 Hp 540 RPM motors
Patented Quiet Edge Fan Blade
• L and Q models only
• Edge Treatment
Variable Speed EC motors
Quiet Edge Fan Blade
6
FN Series has Solutions to Meet Your Noise
Requirements!
Unit Sound Data (dBA @ 10 Ft)
7
FN Series has Solutions to Meet Your Noise
Requirements!
Variable Speed EC Sound Data (dBA @ 10 Ft)
8
FN Series has Solutions for Your Reliability Needs!
 Floating Tube Coil Design
–
–
½” Anchor Tube Design
5/8” Bushing Plate Design
 Fan motors –
–
Thermal overload protection Permanently lubricated ball bearings
½” Anchor Tube Design
 Cabinet Material
–
–
–
9
Galvanized (FNH, FNL and FNQ)
Aluminum (standard FNE)
Painted galvanized steel
5/8” Bushing Plate
FN Series has Solutions for Your Reliability Needs!
 Optional Fin / Coil protection –
–
–
Copper Fins
BohnGuard Fins
Industrial Coating TM
 Unit Factory Tested
–
–
Pressure and leak
Electrical circuit and motor run  Extensive Unit Warranty
–
–
–
10
5 Year against leaks at the tube sheet and center supports
3 year on VSEC motor (FNE Models)
2 year unit warranty
FN Series has Solutions for Your Serviceability Needs!
 Standard 10 Fin per Inch Coil
–
Optional 8 FPI coil availability
 Patented ServiceEase Motor Mount
–
Available on FNH, FNL and FNQ models
Patented ServiceEase Motor Mount
 Optional Hinged Venturies
–
Available on FNH, FNL and FNQ models
Optional Hinged Venturi
11
FN Series has Solutions for Your Serviceability Needs!
 Optional Side Access Panels
–
Standard on FNE models
 Larger Vent and Drain Connections
–
–
12
3/8” Flare vent connection
½” FPT drain connection
Optional Side Access Panel
FN Series has Solutions for Your Application Needs!
 Unit Construction
– High Temperature Motor •
•
185F Air Over
FNH Models only
– Totally Enclosed Motors •
FNH Models only
– Extended Legs •
30””, 36” or 42”
– Unit Frame
•
20” or 42” leg
– Sealtite Wiring
– Connection Options
•
•
Threaded Conns
Flanged Conns
– Manifolds (double wide units)
13
FN Series has Solutions for Your Application Needs!
 Unit Controls –
–
–
–
–
–
–
14
Fan Cycling (on Lvg Fluid Temp)
Control Transformers (230V, 115V or 24V)
Motor Contactors (Individual and Paired)
Fuses or Circuit Breakers (Individual and Paired)
Motor On/Off Toggle Switches
Thru the door Disconnect (non fused and fused)
Custom Control Panels
FN Series has Solutions to Meet Your Initial Cost
Needs!
 High Performance 1140 RPM Fan Motors
–
Increased CFM / heat transfer per fan cell
 ½” Diameter Tube Coil Models
–
Compact efficient heat transfer surface  Aluminum Fin / Copper Tube Coil Construction
 Optional High Density Fin Construction
–
12 and 14 FPI Availability
 Galvanized Steel Cabinet Construction
15
Model Nomenclature
F N H S 04 H 3 08
F = Fluid Cooler
Vintage N
Motor Selection
H = Standard (1140 RPM, 1½ HP)
L = Low noise & energy efficient (830 RPM, 1½ HP)
Q = Quiet, extremely energy
efficient (540 RPM, .5 HP)
E = Efficient, variable speed brushless DC motors
Model Nomenclature
F N H S 04 H 3 08
Unit Width
S = Single Wide
D = Double Wide
Total # of Fans 01 ‐ 12
Model Nomenclature
F N H S 04 H 3 08
Tube Diameter H = ½” F = 5/8”
Number of Rows
2, 3 or 4
Coil Module #
01 to 80
Product Overview – Model Map
Fan Config
1x1
1x1
1x2
1x2
1x2
1x3
1x3
1x4
1x4
1x5
1x5
1x6
1x6
2x2
2x2
2x2
2x3
2x3
2x4
2x4
2x5
2x5
2x6
2x6
E, 1/2"
E, 5/8"
H, 1/2"
H, 5/8"
L, 1/2"
L, 5/8"
Q, 1/2"
Q, 5/8"
FNE‐S01‐H361
FNE‐S01‐H462
FNE‐S02‐H263
FNE‐S02‐H364
FNE‐S02‐H465
FNE‐S03‐H366
FNE‐S03‐H467
FNE‐S04‐H368
FNE‐S04‐H469
FNE‐S05‐H370
FNE‐S05‐H471
—
—
FNE‐D04‐H272
FNE‐D04‐H373
FNE‐D04‐H474
FNE‐D06‐H375
FNE‐D06‐H476
FNE‐D08‐H377
FNE‐D08‐H478
FNE‐D10‐H379
FNE‐D10‐H480
—
—
—
—
—
—
—
FNE‐S03‐F361
FNE‐S03‐F462
FNE‐S04‐F363
FNE‐S04‐F464
FNE‐S05‐F365
FNE‐S05‐F466
FNE‐S06‐F367
FNE‐S06‐F468
—
—
—
FNE‐D06‐F371
FNE‐D06‐F472
FNE‐D08‐F373
FNE‐D08‐F474
FNE‐D10‐F375
FNE‐D10‐F476
FNE‐D12‐F377
FNE‐D12‐F478
FNH‐S01‐H301
FNH‐S01‐H402
FNH‐S02‐H203
FNH‐S02‐H304
FNH‐S02‐H405
FNH‐S03‐H306
FNH‐S03‐H407
FNH‐S04‐H308
FNH‐S04‐H409
FNH‐S05‐H310
FNH‐S05‐H411
—
—
FNH‐D04‐H212
FNH‐D04‐H313
FNH‐D04‐H414
FNH‐D06‐H315
FNH‐D06‐H416
FNH‐D08‐H317
FNH‐D08‐H418
FNH‐D10‐H319
FNH‐D10‐H420
—
—
—
—
—
—
—
FNH‐S03‐F301
FNH‐S03‐F402
FNH‐S04‐F303
FNH‐S04‐F404
FNH‐S05‐F305
FNH‐S05‐F406
FNH‐S06‐F307
FNH‐S06‐F408
—
—
—
FNH‐D06‐F311
FNH‐D06‐F412
FNH‐D08‐F313
FNH‐D08‐F414
FNH‐D10‐F315
FNH‐D10‐F416
FNH‐D12‐F317
FNH‐D12‐F418
FNL‐S01‐H321
FNL‐S01‐H422
FNL‐S02‐H223
FNL‐S02‐H324
FNL‐S02‐H425
FNL‐S03‐H326
FNL‐S03‐H427
FNL‐S04‐H328
FNL‐S04‐H429
FNL‐S05‐H330
FNL‐S05‐H431
—
—
FNL‐D04‐H232
FNL‐D04‐H333
FNL‐D04‐H434
FNL‐D06‐H335
FNL‐D06‐H436
FNL‐D08‐H337
FNL‐D08‐H438
FNL‐D10‐H339
FNL‐D10‐H440
—
—
—
—
—
—
—
FNL‐S03‐F321
FNL‐S03‐F422
FNL‐S04‐F323
FNL‐S04‐F424
FNL‐S05‐F325
FNL‐S05‐F426
FNL‐S06‐F327
FNL‐S06‐F428
—
—
—
FNL‐D06‐F331
FNL‐D06‐F432
FNL‐D08‐F333
FNL‐D08‐F434
FNL‐D10‐F335
FNL‐D10‐F436
FNL‐D12‐F337
FNL‐D12‐F438
FNQ‐S01‐H341
FNQ‐S01‐H442
FNQ‐S02‐H243
FNQ‐S02‐H344
FNQ‐S02‐H445
FNQ‐S03‐H346
FNQ‐S03‐H447
FNQ‐S04‐H348
FNQ‐S04‐H449
FNQ‐S05‐H350
FNQ‐S05‐H451
—
—
FNQ‐D04‐H252
FNQ‐D04‐H353
FNQ‐D04‐H454
FNQ‐D06‐H355
FNQ‐D06‐H456
FNQ‐D08‐H357
FNQ‐D08‐H458
FNQ‐D10‐H359
FNQ‐D10‐H460
—
—
—
—
—
—
—
FNQ‐S03‐F341
FNQ‐S03‐F442
FNQ‐S04‐F343
FNQ‐S04‐F444
FNQ‐S05‐F345
FNQ‐S05‐F446
FNQ‐S06‐F347
FNQ‐S06‐F448
—
—
—
FNQ‐D06‐F351
FNQ‐D06‐F452
FNQ‐D08‐F353
FNQ‐D08‐F454
FNQ‐D10‐F355
FNQ‐D10‐F456
FNQ‐D12‐F357
FNQ‐D12‐F458
19
Important Dates:
20

Sales Release:
 October 1st

BFH/RF6/HFS Last Order
 Estimated December 31st

Lead Times
 ½” Models: 3 to 4 weeks ex factory
 5/8” Models: 4 to 6 weeks ex factory
Model Cross Reference
Bohn
Single Wide Units
21
Current Model
New FN Model
Notes
BFH023
FNH-S02-H203
Configure FNH with 14 FPI
BFH027
FNH-S02-H304
BFH031
FNH-S02-H304
Configure FNH with 14 FPI
BFH035
FNH-S02-H405
Configure FNH with 14 FPI
BFH041
FNH-S03-H306
BFH045
FNH-S03-H306
Configure FNH with 14 FPI
BFH049
FNH-S03-H407
Configure FNH with 12 FPI
BFH053
FNH-S04-H308
BFH061
FNH-S04-H308
Configure FNH with 14 FPI
BFH065
FNH-S04-H409
Configure FNH with 12 FPI
BFH071
FNH-S04-H409
Configure FNH with 14 FPI
BFH075
FNH-S05-H310
Configure FNH with 14 FPI
BFH079
FNH-S05-H411
BFH089
FNH-S05-H411
Configure FNH with 14 FPI
BFH097
FNH-S06-F408
5/8" Model
BFH107
FNH-S06-F408
5/8" Model Configure FNH with 14 FPI
Model Cross Reference
Bohn
Double Wide Units
22
Current Model
New FN Model
Notes
BFH046
FNH-D04-H212
Configure FNH with 14 FPI
BFH054
FNH-D04-H313
BFH060
FNH-D04-H313
Configure FNH with 14 FPI
BFH066
FNH-D04-H414
Configure FNH with 12 FPI
BFH070
FNH-D04-H414
Configure FNH with 14 FPI
BFH080
FNH-D06-H315
BFH086
FNH-D06-H315
Configure FNH with 12 FPI
BFH090
FNH-D06-H315
Configure FNH with 14 FPI
BFH098
FNH-D06-H416
Configure FNH with 12 FPI
BFH106
FNH-D08-H317
BFH120
FNH-D08-H317
Configure FNH with 14 FPI
BFH132
FNH-D08-H418
Configure FNH with 12 FPI
BFH140
FNH-D08-H418
Configure FNH with 14 FPI
BFH152
FNH-D10-H319
Configure FNH with 14 FPI
BFH162
FNH-D10-H420
BFH168
FNH-D10-H420
Configure FNH with 12 FPI
BFH178
FNH-D10-H420
Configure FNH with 14 FPI
BFH194
FNH-D12-F418
5/8" Model
BFH202
FNH-D12-F418
5/8" Model Configure FNH with 12 FPI
BFH212
FNH-D12-F418
5/8" Model Configure FNH with 14 FPI
ProSelect™ Product Selector – Opening Selection
Choose ‐
1. Brand:
User Preference
2. Category: Fluid Coolers (not selectable on web‐version)
23
ProSelect™ Product Selector – Opening Selection
Choose ‐
1. Brand:
User Preference
2. Category: Fluid Coolers (not selectable on web‐version)
3. Type: Large Sizes 4. Power:
60 Hz (default)
5. OK: Click in lower right corner to proceed
ProSelect™ Product Selector – Selection Criteria
Choose/Enter ‐
1. Style:
Previous Screen
2. Data Sheet: Brief Description
3. Unit Quantity: Number to handle load
4. Voltage: *
Power Supply
5. FPI: * (new)
8, 10, 12, or 14
6. Max Press Drop:
in feet of water
* “No Preference” will increase time to process selections.
25
ProSelect™ Product Selector – Selection Criteria
Choose/Enter ‐
7. Max Length:
in inches
8. Max Width:
in inches
9. Max Height:
in inches
10. Max Weight:
in pounds
11. Family: *
FNH/L/Q/E
* “No Preference” will increase time to process selections.
26
ProSelect™ Product Selector – Selection Criteria
Choose/Enter ‐
12. % Glycol: (new)
0 to 50%
13. Glycol Type: (new) Ethylene or Propylene
14. Altitude:
in feet
15. Ent Air Temp:
50 to 190°F
27
ProSelect™ Product Selector – Selection Criteria
Choose/Enter ‐
16. Fluid Flow: in GPM
17. Ent Fluid Temp:
60 to 200°F
18. Lvg. Fluid Temp.:
in °F*
19. System Load:
in BTUH**
* If Lvg Fluid is entered, System Load is calculated.
**If System Load is entered, Lvg Fluid is calculated.
28
ProSelect™ Product Selector – Equipment
Choose/Enter ‐
1. Selection Range: 15 to 300%
2. Refresh:
click to refresh
3. Equip Window:
Scroll bars to see more selections
Click on model to select (shown at bottom)
Sound data new
29
ProSelect™ Product Selector – Options
Choose ‐
1. Options: Additional new options similar to NTC. 2. Coil: FPI and protection are combined. Bronz Glow to
be entered as Custom Option.
3. Fan Cycling: select contactor first for FNH, FNL and FNQ models
4. Rules: Options do have rules associated.
30
QUESTIONS
31
Download