1 e lin e th rs ss acto o r t Ac con 1 Accessories for A/AF/AL & AE contactors Auxiliary contact blocks – Standard Maximum number of contact blocks Positioning 4 blocks: A9 – A26 AE9 – AE26 Front mounting AL9 – AL26 (single pole) 5 blocks: A30, A40, AE30, AE40, AL30, AL40 6 blocks: A45 – A110 AE45 - AE110 AF45 - AF110 CAL5-11 CA5-10 A9 – A26-40-00 A30 – A110 Front mounting 1 block: AE9 – AE110 (4 pole) 1 block: A9 – A40-30-10 AL9 – AL40-30-10 2 blocks: A9 – A75, AE9-AE45 1 block: AE50 – AE75, AL9 – AL40 Side mounting 1 block: AE95 - AE110 (2 pole) 2 blocks: A145 – A300, AF145-AF1650 2 blocks: A145 – A300, AF145-AF1650 Contact Description Catalog number 1 N.O. 1 N.C. CA5-10 CA5-01 1 N.O. Early make 1 N.C. Late break CC5-10 CC5-01 4 N.O. 3 N.O. & 1 N.C. 2 N.O. & 2 N.C. 4 N.C. 2 N.O./2 N.C.1 CA5-40E CA5-31E CA5-22E CA5-04E CA5-11/11E 3 N.O. & 1 N.C. 2 N.O. & 2 N.C. 1 N.O. & 3 N.C. 4 N.C. 4 N.O. 2 N.O./2 N.C.1 CA5-31M CA5-22M CA5-13M CA5-04M CA5-40N CA5-11/11M 1 N.O. & 1 N.C. CAL5-11 1 N.O. & 1 N.C. CAL18-11 List price $ 15 30 1 N.O. & 1 N.C. (inside L or R) CAL18-11 1 N.O. & 1 N.C. (outside, L or R) CAL18-11B Auxiliary contact blocks – Front mounting, switching low voltage and low current Positioning Front mounting (single pole) Maximum number of contact blocks Contact Description Degree of protection Catalog number List price 4 blocks: A9 – A26 AE9 – AE26 AL9 – AL26 1 N.O. 1 N.C. 1 N.O. 1 N.C. IP40 IP40 IP40 IP40 CE5-10D0.1 CE5-01D0.1 CE5-10D2 CE5-01D2 $ 38 5 blocks: A30, A40, AE30, AE40, AL30, AL40 6 blocks: A45 – A110 AE45 - AE110 AF45 - AF110 1 N.O. 1 N.C. 1 N.O. 1 N.C. IP67 IP67 IP67 IP67 CE5-10W0.1 CE5-01W0.1 CE5-10W2 CE5-01W2 42 1 Includes 1 N.O. & 1 N.C. overlapping 1.16 AC 1000 - 11/03 Discount schedule ABA Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Ac ro co ss nt the ac to line rs Accessories for A/AF/AL & AE contactors 1 Pneumatic timers Mounting on Timing range A9 – A75 AE9 – AE75 AL9 – AL40 On delay 0.1 – 40 s On delay 10 – 180 s Off delay 0.1 – 40 s Off delay 10 – 180 s Contacts N.O. N.C. 1 1 1 1 1 1 1 1 Catalog number TP40DA TP180DA TP40IA TP180IA List price $ 108 Interlocks for two horizontally mounted contactors – A9 - A110 TP40DA Feature Mounting on Mechanical/electrical Mechanical/electrical Mechanical A/AE/AL9 – A/AE/AL40 A45 – A110 A/AE/AL9 – A/AE/AL40 Contacts N.O. N.C. — — — 2 2 — Catalog number VE5-1 VE5-2 1 VM5-1 List price $ 45 45 21 Interlocks for two horizontally mounted contactors – A95 - AF750 contactors Left contactors Right contactors A95 – A300 A210 – A300 AF400 – AF750 A145 – A300 AF400 – AF460 AF400 – AF750 Feature Mechanical Mechanical Mechanical VE5-1 Catalog number VM300H VM300/460H VM750H List price $ 110 130 150 Interlocks for two vertically mounted contactors – A95 - AF750 contactors Top contactor Feature Mechanical Mechanical Mechanical VM300H A95 – A300 A210 – A300 AF400 – AF750 Mounting on Connects from side Connects from top Connects from side LK75-A1 A145 – A300 AF400 – AF460 AF400 – AF750 Catalog number VM300V VM300/460V VM750V List price $ 205 250 270 Auxiliary lead terminals (Set of 2) Connections LK75-A Bottom Contactor A50 – A75 A50 – A75 A95 – A110 Catalog number LK75-A LK75-A1 LK110 List price $ 15 15 23 LK110 1 Use type VE 5-2 for mechanical and electrical interlocking between A30/A40 and A50 - A75 contactors. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule ABA 1.17 AC 1000 - 11/03 1 1 e lin e th rs ss acto o r t Ac con 1 Positioning Accessories Possible accessory combinations for A contactors Accessories — Front face mounting Top Auxiliary contacts 1 – pole 4 – pole Front face Left side CA5-10 or CA5-01 CA5-40 or CA5-22 or CA5-31 Accessories — Side mounting Pneumatic timers Auxiliary contacts TP – D or TP – I CAL 5-11 CAL18-11 CAL18-11B Electrical or mechanical interlock1 VE5-1 or VM 5-1 VE 5-2 VM300H VM300/460H VM750H Configurations of accessories are different depending on whether front or side mounted. N Contactor relays A and AE Contactors Accessories — Front mounting Auxiliary contact blocks TP - A Pneumatic 1-pole CA54-pole CA5timer block Type Main poles Built-in auxiliary contacts A9 – A26 A9 – A26 A9 – A26 A9 – A26 AE9 – AE26 AL9 – AL26 – – – – – – – – – – – – A9 – A16 A9 – A26 – 3 0 – 2 2 – 3 0 – 3 2 — A30, A40 AL30, AL40 A30, A40 AL30, AL40 AE30, AE40 – – – – – 1 to 5 CA5- A30, A40 – 3 0 – 3 2 A50 – A75 A45 – A75 A45, A75 A95, A110 – – – – A50 – A75 A95, A110 – 3 0 – 2 2 – 3 0 – 2 2 AE50 – AE75 AE45 – AE75 AE45, AE75 AE95, AE110 – – – – 3 4 2 3 0 0 2 0 – – – – 0 0 0 0 0 0 0 0 A50 – A75 AE50, AE75 A95, A110 AE95, AE110 – – – – 3 3 3 3 0 0 0 0 – – – – 1 1 1 1 1 1 1 1 3 3 4 2 3 3 3 3 3 3 3 3 4 2 3 0 0 0 2 0 0 0 0 0 0 0 0 0 2 0 – – – – – – – – – 1 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 1 0 0 0 0 1 A145 – AF1650 – 3 0 – 0 0 OR 1 CA54-pole block + 1 to 2 CAL5-11 blocks OR 1 VM/E 5-1 block + 1 CAL5-11 block — + 1 to 2 CAL5-11 blocks OR 1 TP - A block + 1 to 2 OR 1 VM/E 5-1 block OR 1 TP - A block 1 0 0 1 1 0 0 0 0 0 1 to 4 CA51-pole blocks Accessories — Side mounting Auxiliary contact Blocks Interlock units 2-pole CAL5-11, CAL18-11 — OR OR 1-pole blocks + 1 CA5- 1-pole block + 1 CA5- 1-pole block CAL5-11 blocks + 1 CAL5-11 block 1 CA51-pole block — — + 1 to 2 CAL5-11 blocks OR 1 VM/E 5-1 block + 1 CAL5-11 block 1 to 6 CA51-pole blocks 1 CA5- 4-pole block + 2 CA5- 1-pole blocks + 1 to 2 1 VE5-2 block OR + 1 CAL5-11 block CAL5-11 blocks 2 CAL18-11 blocks 1 VE5-2 + CAL5-11 + 1 to 2 CAL5-11 blocks 1 VE5-2 block OR + 1 CAL5-11 block + 1 CAL5-11 block 1 CAL5-11 block 1 CAL5-11 block 1 CAL18-11 block OR 1 CAL5-11 block — 1 CAL18-11 block — 1 VE5-2 block OR — 1 VE5-2 block OR — 2 OR 2 CA51-pole blocks 2 1 CA5- 4-pole block 1 VM/E 5-1 block + 1 CAL5-11 block OR 1 to 6 CA51-pole blocks OR — OR — 1 to 6 CA51-pole blocks 1 CA5- 4-pole block + 2 CA5- 1-pole blocks 1 CA5- 4-pole block + 2 CA5- 1-pole blocks — 1 TP - A block + 2 CA51-pole blocks — — OR 1 TP - A block + 2 CA51-pole blocks — OR 1 TP - A block + 2 CA51-pole blocks — — + 1 VE5-2 block 1 to 2 1 CAL18-11 block + 1 CAL18-11B block CAL18-11 blocks OR + VM300H or VM300/460H + 1 to 2 CAL18-11B blocks or VM750H interlock Contactor mounting configurations (standard from factory) Auxiliary contacts are mounted on the contactor in the following order: Left – 1st Right – 2nd Top – 3rd (L to R) 1 In mounting position 5 (see page 1.36), there should be no more than 2 "N.C." front-mounted auxiliary contacts – The CAL 5-11 side-mounted blocks offer additional "N.C." contacts. 2 Whatever the mounting position (see page 1.36), there should be no more than 2 "N.C." front-mounted auxiliary contacts – The CAL 5-11 side-mounted blocks offer additional "N.C." contacts. 1.18 AC 1000 - 11/03 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Ac ro co ss nt the ac to line rs Accessories Auxiliary contact block technical data CA5/CAL5-11/CAL18-11/CC5 Types 1-pole CA5, 4-pole CA5 2-pole CAL5-11 and 1-pole CC5 1 CAL18-11 CAL18-11B IEC 947-5-1 and EN 60947-5-1 Standards Rated insulation voltage Ui according to IEC 947-5-1 according to UL/CSA 690 600 V V Rated operational voltage Ue 690 690 24 to 690 ~V A 16 24 to 127 V 220 to 240 V 380 to 440 V 500 to 690 V A A A A 6 4 3 2 24 V 48 V 72 V 125 V 250 V A A A A A 6 2.8 1 0.55 0.3 Conventional thermal current Ith Rated operational current Ie in AC-15 acc. to IEC 947-5-1 in DC-13 acc. to IEC 947-5-1 M 3.5 (+,-) pozidriv 2 screw with cable clamp Connecting terminals (delivered in open position. Screws of unused terminals should be tightened). Connecting capacity • Rigid solid 1 or 2 x mm2 1 to 4 1 x mm2 2 x mm2 • Flexible with cable end 0.75 to 2.5 0.75 to 2.5 cycles Mechanical durability Max. switching frequency Electrical durability Max. switching frequency 10 million, A9 - A75; 3 million, A95 & A110; 5 million, A/AF95 - A/AF185; 3 million, A/AF210 - AF750; 0.5 million, AF1350 & AF1650 cycles/h 3600 cycles/h See curve below 1200 10 x Ie AC-15 10 x Ie AC-15 Rated making capacity Rated breaking capacity 1s 0.1 s Rated short-time withstand current Icw q = 40°C 100 140 A A 17 V / 5 mA, A9 - A75; 24V / 50 mA, A95 & A110 Min. switching capacity 24V / 50 mA Short-circuit protection - gG (gl) fuses A 10 Power loss per pole at 6 A W 0.15 Degree of protection according to IEC 529, IEC 144, DIN 40 050 and NFC 20-010 IP 20 CAL18 CA5, CAL5 Million ops. 30 30 20 20 10 10 5 Million ops A/AF95...A/AF185 5 A/AF210...AF750 3 2 1 AF1350/AF1650 0.5 2 1 0.5 0.3 0.2 0.1 0.02 CA 5, CAL 5 3 0.3 0.2 0.05 0.1 0.2 0.3 0.5 1 2 3 4 5 6 Breaking current (A) 10 0.1 0.02 0.05 0.1 0.2 0.3 0.5 1 2 3 4 5 6 10 Breaking current (A) Electrical durability AC-15 according to IEC 947-5-1 making current: 10 x Ie where cos ϕ = 0.7 and Ue breaking current: Ie where cos ϕ = 0.4 and Ue The curves opposite show the electrical durability of the auxiliary contact blocks according to breaking current Ic. These curves have been plotted for resistive and inductive loads up to 690 V, 40 to 60 Hz. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 1.19 AC 1000 - 11/03 1 1 e lin e th rs ss acto o r t Ac con 1 Accessories Auxiliary contact block technical data CE5 Auxiliary contact blocks for switching low level voltage and current Types CE5-10D0.1 CE5-01D0.1 CE5-10W0.1 CE5-01W0.1 CE5-10DZ CE5-01DZ CE5-10WZ CE5-01WZ Version 100 mA Version 2 A Standards IEC 947-5-1 and EN 60947-5-1 Approvals UL / CSA Rated insulation voltage Ui according to IEC 947-5-1 according to UL/CSA V V 250 125 250 250 Rated operational voltage Ue V 125 250 A A A A A 0.1 0.1 0.1 0.1 0.1 2 2 0.5 0.2 0.1 Rated operational current Ie in AC-15 or AC-14 acc. to IEC 947-5-1 in DC-12 acc. to IEC 947-5-1 24 V 60 V 110 V 220 V 3 V / 1 mA Minimal switching 10 Reliability for the minimal switching M3.5 (+,-) posidriv 2 screw with cable clamp Connecting terminals Connecting capacity • Rigid solid • Flexible with cable end 1 ou 2 (1...4) mm2 1 ou 2 (0.75... 2.5) mm2 100 mA Short circuit protection Degree of protection according to IEC529, IEC 144, DIN 40 050, NFC 20-010 Mounting Dimensions 1.20 AC 1000 - 11/03 17 V / 5 mA -8 10 A IP 20 Front mounting on contactors: A, AE, TAE9...110, AL, AF, GA, N, NE Identical to those of CA5 single pole Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Accessories Surge suppressors for A/AE/AL/EK contactors Ac ro co ss nt the ac to line rs 1 Surge suppression device Mounting on Voltage range AE9 to AE110 AL9 to AL40 A9 to A110; AE9 to AE110 AL9 to AL40 RV 5/50 A9 to A40 A45 to A300 RC 5-1/150 Catalog number 12 25 50 77 150 – – – – – 32 VDC 65 VDC 90 VDC 150 VDC 264 VDC RT5/32 RT5/65 RT5/90 RT5/150 RT5/264 24 50 110 250 – – – – 50 VAC/VDC 133 VAC/VDC 250 VAC/VDC 440 VAC/VDC RV5/50 RV5/133 RV5/250 RV5/440 24 50 110 250 – – – – 50 VAC 133 VAC 250 VAC 440 VAC RC5-1/50 RC5-1/133 RC5-1/250 RC5-1/440 24 50 110 250 – – – – 50 VAC 133 VAC 250 VAC 440 VAC RC5-2/50 RC5-2/133 RC5-2/250 RC5-2/440 EK110 to EK210 24 – 48 VAC 110 – 415 VAC RC-EH250/48 RC-EH250/415 EK370 to EK550 48 – 110VAC RC-EH800/110 EK110 to EK550 24 – 125VAC RC-EH800/110 EK370 to EK550 220 – 600VAC RC-EH800/600 List price $ 30 26 Technical data Type Control circuit Opening time growth factor Residual overvoltage or clipping voltage 2.5 to 3 50 V 100 V 150 V 210 V 390 V Advantages RT 5 /... transil diode 32 65 90 150 264 Varistor RV 5/... 50 133 250 440 RC 5-1/... or RC 5-2/... RC-EH 300/... Varistor + RC Remarks see table above DC DC DC DC DC AC/DC AC/DC AC/DC AC/DC 1.1 to 1.5 132 V 270 V 480 V 825 V AC RC-EH ... 800/110 AC/DC 800/600 AC 1.2 to 3 2 to 3 x Uc 1.1 to 1.5 205 V 1100 V Drawback • • • • Good energy absorption Unpolarized system Simple, reliable system A certain delay on drop out which does not however reduce contactor breaking capacity. Advantages • High energy absorption; good damping • Unpolarized system Drawback • Clipping as from Uvdr, thus voltage front up to this point Advantages • Very fast clipping • Attenuation of steep fronts and thus of high frequencies • No operating delays Advantages • High energy absorption: good damping • Unpolarized system • The RC system damps the voltage front under the Uvdr* threshold. *Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ± 10% Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule ABA 1.21 AC 1000 - 11/03 1 1 Accessories Surge suppressors for A/AE/AL/EK contactors General information General U (V) The operation of inductive circuits causes overvoltages, in particular on opening of the contactor coil. 1000 T (µs) 0 1000 0 100 100 The electromagnetic energy stored by the coil during contactor closing is restored on opening in the form of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are observed ranging from interference on the electronic devices to breakdown of insulators and even destruction of certain sensitive components. The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42V/50Hz coil without peak clipping. The coil was switched by 8 series-connected poles of a contactor relay. Following a burst of discharges with a very steep slope a damped oscillation emerges with a peak value of 3500V. Overvoltage factor The overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak value Ûc of the coil rated control voltage Uc: Ûs max. k = _______ Ûc in DC: Ûs max. k = _______ Uc or in AC: Ûs max. k = _______ Uc√2 3500 For example the following is obtained for the above graph: k = _____ ≈ 60 42 √2 Surge suppressors To guard against the harmful effects of these overvoltages, ABB has developed a range of surge suppressors designed to reduce the k factor defined above and to limit or even completely eliminate the high pre-damping voltage frequencies. Each case is different, but the technical data tolerances and the generous sizing of parts have enabled us to reduce the number of variants. We have chosen the following solutions: transil diodes, varistors and RC blocks. Note: A varistor is a resistor whose value increases to a very large extent when a certain voltage is applied at its terminals. Wiring diagrams Transil diode RC type Varistor (only) Varistor + RC A1 A1 A1 A1 A2 A2 A2 A2 U 1 e lin e th rs ss acto o r t Ac con General technical data The housings and impregnation resins of the surge suppressors are made of flame-resistant materials in accordance with the UL 94 standard. These systems are not polarized, i.e. d.c. operated devices do not have to be connected in a specific direction. • Operating temperature: -20 to +70 °C • Connection to the coil terminals (parallel mounting) – For RT 5, RV 5, RC 5-1 and RC 5-2: clip-on for both fixing and connection. • Mounting: – RT 5, RV 5 and RC 5: clipped onto the top part of the contactor base. This mounting method prevents any projections and change in contactor dimensions. – RC-EH: glued to the top part of the contactor base. 1.22 AC 1000 - 11/03 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Ac ro co ss nt the ac to line rs Accessories Interface relays for A contactors 1 Interface relays Mounting on contactor types Coil voltages N, A9 – A110 24 – 250V, 50, 60 Hz Catalog number List price RA5 $ 75 Description RA5 interface relays are designed to receive 24 VDC signals delivered by PLCs or other sources with a low output power and to restore them with sufficient power to operate the coils of the relevant contactors Types • RA5 for combination with A9 – A110 contactors and N contactor relays. A30-30-10 + RA 5 Description RA5 interface relays are made up of a miniature electromechanical relay equipped with a N.O. contact and with a low consumption 24 VDC coil. The interface relay coil is controlled by the PLC while the N.O. contact ensures switching of the power contactor. Coil switching gives rise to overvoltages which have adverse effects on the electronic devices, insulators and, more generally, on component lifetime. The RA 5 is equipped with surge suppressors: • on the 24 VDC relay coil via a diode • on the power contactor coil via a varistor. RA 5 Furthermore, the RA5 are protected against relay pole reversal by a diode inserted between the E1 and E2 input terminals. Connection The “E1+” and “E2–” input terminals must be connected, according to their polarity, to the PLC output. • The RA 5 is equipped with two terminal pads for connection to the A1 and A2 terminals of the contactor coil. This coil is supplied between the A0 and A2 terminals of the RA 5. RA 5 interface relay for the A 9 – A 110 contactors and N control relays PLC Output A0 Uc 250 VAC – A2 E2 – + 24 VDC E1 + RA 5 A1 KM1 A2 Mounting • RA5: terminal pads clamped inside the contactor coil terminals. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule ABA 1.23 AC 1000 - 11/03 1 1 e lin e th rs ss acto o r t Ac con 1 Accessories Interface relay technical data General technical data IEC 255-5 Standards Rated insulation voltage Ui acc. to IEC 947-4-1 and VDE 0110 VAC Permissible ambient temperature • For free air operation: – at Ue = 24VDC (between E1 & E2) – from 0.85 to 1.1 Ue • For storage °C °C °C -25 to + 70 -25 to +55 -40 to +70 Complies with that of associated contactors Climatic withstand No limitation Mounting position meters Operating height 3000 Using the contactor A1 and A2 terminal connecting points Cable clamps and M 3.5 (+, –) pozidriv screws (2) Mounting Connecting terminals (open on delivery) Cable cross-sectional area: • Rigid solid • Flexible 250 2 x mm2 2 x mm2 1 to 4 0.75 to 2.5 Protection against direct contact acc. to VDE 0106, Part 100 Degree of protection Construction data Surge suppression: • For contactor coil • For interface relay coil Varistor Diode Diode Protection against polarity reversal between terminals E1 and E2 Use on contactors with coils: • 24 to 250V/50, 60 Hz • 12 to 250VDC Interface relay operating time Total operating time, interface relay + contactor • Between energization and: – NO contact opening – NC contact opening • Between de-energization and: – NO contact opening – NC contact opening types types ms N, A9 – A110 AL9 – AL40 ms ms 19 to 36 16 to 32 ms ms 15 to 25 18 to 28 VDC VDC 24 17 to 30 Electrical input data Control voltage (E1 and E2 terminals) Uc: • Rated value • Maximum range Max. consumption for Uc = 24 VDC, Ø=20°C W 0.3 “0” status (relay open) • For Uc • For Ic VDC mA ≤ 2.4 ≤1 “1” status (relay closed) for Uc VDC ≥ 17 Max. short supply interruption immunity time ms 4 Electrical output data Switching voltage (A0 and A2 terminals) Electrical lifetime 1.24 AC 1000 - 11/03 VAC VDC millions of operations ≤ 250 – 4 (600 ops.h) on A9 – A40 2 (600 ops./h) on A45 – A110 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Ac ro co ss nt the ac to line rs Accessories for A/AE/AL/AF contactors 1 Terminal lug kits (Set of 3) Wire range For contactor 6 – 250 MCM 4 – 400 MCM (2) 4-500 MCM (2) 2/0 – 500 MCM (3) 2/0 – 500 MCM (4) 4/0 – 500 MCM (4) 1/0 – 750 MCM (6) 1/0 – 750 MCM ATK185 Catalog number A145 – A185 A210 – A300 A210 – A300 AF400 – AF580 AF580 – AF750 AF1350 AF1350 – AF1650 AF1350 – AF1650 List price ATK185 ATK300 ATK300/2 ATK580/2 ATK750/3 ATK1350/4 ATK1650/4 ATK1650/6 Contact kits $ 45 68 110 150 225 235 335 560 Catalog number For contactors List price 3 Pole ATK750/3 ZL75 A/AE/AF50 A/AE/AF63 A/AE/AF75 A/AE/AF95 A/AE/AF110 ZL50 ZL63 ZL75 ZL95 ZL110 $ 113 135 158 225 255 A/AF145 A/AF185 A/AF210 A/AF260 A/AF300 ZL145 ZL185 ZL210 ZL260 ZL300 300 420 525 855 1020 AF400 AF460 AF580 AF750 AF1350 AF1650 ZL400 ZL460 ZL580 ZL750 ZL1350 ZL1650 1716 2434 3795 3960 4255 4890 A/AE45 A/AE50 A/AE75 ZLT45 ZLT50 ZLT75 150 150 210 UA50 UA75 UA95 UA110 ZLU50 ZLU75 ZLU95 ZLU110 150 215 306 347 4 Pole 3 Pole Mechanical latches Catalog number For contactors ZL145 A9 - A75, AE45 - AE75, & AL9 - AL40 List price WB75A-★ $ 84 ★ - Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the ★. Coil voltage selection chart — mechanical latches for A, AE & AL contactors 50 Hz (DC) 24 42 48 110 WB75A-04 Voltage code 60 Hz (AC) 24 42 48 110 – – – – 28 48 55 127 01 02 03 04 50 Hz (DC) 220 230 380 415 – – – – 230 240 415 440 Voltage code 60 Hz (AC) 220 230 380 440 – – – – 255 277 440 480 06 05 07 08 Range: WB75A for contactors A9 – A75, AL9 – AL40, AE45 – AE75 and control relays N and NL. Description: WB75A block: contains a mechanical latching device with electromagnetic impulse unlatching (AC or DC) or manual unlatching. Captive screw type connecting terminals, built-in cable clamps, M 3.5 (=, -) posidrive 1 screw with screwdriver guidance, delivered untightened and protected against accidental direct contact. Operation: After closing, the contactor continues to be held in the closed position by the latching mechanisim should the supply voltage fail at the contact coil terminals. Contactor opening can be controlled: • • Electrically by an impulse* (AC or DC) on the WB75A block coil. The coil is not designed to permanently energized. Manually by pressing the pushbutton on the front face of the WB75A block. Mounting: WB75A is clipped onto the front face of the contactor. Identification markers Mounting on BA5-50 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Coil voltage A/AE/AL/AF9 – A/AE/AL/AF110 Discount schedule ABA Pack of 50 Catalog number List price BA5-50 $ 15 1.25 AC 1000 - 11/03 1 1 e lin e th rs ss acto o r t Ac con 1 Accessories for A/AE/AL/AF contactors Coils & coil voltage codes Coils — AC operated Catalog number For contactors List price A9 A26 A45 A95 A145 A210 – – – – – – A16 A40 A75 A110 A185 A300 ZA16-★ ZA40-★ ZA75-★ ZA110-★ ZA185-★ ZA300-★ $ 24 30 57 60 150 180 AE9 AE26 AE45 AE95 – – – – AE16 AE40 AE75 AE110 ZAE16-★ ZAE40-★ ZAE75-★ ZAE110-★ 24 30 57 90 CCL18-01 45 ZA16-81 Coils — DC operated Auxiliary including an insertion contact and a varistor for DC operated contactors AE95 – AE110 Coils — AC/DC operated AF45 – AF75 AF95, AF110 AF145 – AF185 AF210 – AF300 AF400, AF460 AF580, AF750 AF1350, AF1650 (Set of 2)) ZAF1650 ZAF75-★ ZAF110-★ ZAF185-★ ZAF300-★ ZAF460-★ ZAF750-★ ZAF1650-★ 120 165 200 240 450 525 920 Printed circuit board — AC/DC operated AF1350 – AF1650 ZP1650 1620 ★ – Coil voltage suffix. Refer to Coil Voltage Selection charts below and substitute the desired coil voltage code for the ★. ZP1650 Coil voltage selection — DC operated for AE contactors Coil voltage selection — AC operated for A9 – A300; UA26 – UA110 1 2 3 4 5 VAC (50Hz) VAC (60Hz) 24 26 28 42 48 60 100 110 110 – 115 120 125 – 127 175 190 200 220 – 230 230 – 240 230 – 240 230/400 — 380 – 400 400 – 415 — 440 500 550 660 – 690 24 28 32 42 48 60 100 – 110 110 – 120 115 – 127 140 150 208 220 200 – 220 230 – 240 240 – 260 277 — 230/400 400 – 415 415 – 440 480 500 600 — — VDC Voltage code AE contactors 12 24 42 48 50 60 75 110 125 220 240 250 80 81 82 83 21 84 85 86 87 88 89 38 Voltage Code 81 16 17 82 83 73 74 2 84 89 3 29 30 34 36 75 2 80 88 42 62 1 63 1 85 86 51 53 55 56 58 Coil voltage selection — AC/DC operated for AF50 – AF750 VAC & VDC 40-60 Hz 24 – 60 VDC 20 – 60 VDC 48 – 130 VAC/VDC 100 – 250 VAC/VDC Suffix Code 68 4 72 5 69 70 Only for A9 – A16. Not for A145 – A300 A145 – A300 at 60 Hz, 115V only. AF400 – AF750, DC only. AF145 – AF300. 1.26 AC 1000 - 11/03 Discount schedule ABA Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Ac ro co ss nt the ac to line rs Accessories for EK contactors Coils & coil voltage codes Coils — AC & DC operated AC Coils Contactor size Catalog number EK110, EK150 EK175, EK210 EK370, EK550 KH210-★ KH300-★ KH800-★ 1 DC Coils List price $ 100 120 290 Catalog number List price KH210-★ KH300-★ KH800-★ $ 130 160 350 ★ – Coil voltage suffix. Refer to the Coil Voltage Selection chart and substitute the desired coil voltage suffix for the ★. AC and DC operated contactors DO NOT have the same magnet structure. Therefore, DC coils will not fit on an AC magnet structure and vice versa. Coil voltage selection — AC operated for EK110 – EK550 Coil voltage selection — DC operated for EK110 – EK550 VAC (50Hz) VAC (60Hz) Voltage Code – 24 – 110 – – 220 – 230 – 380 – 400 400 – 415 – 500 – 24 – 48 120 208 240 – 380 440 – 480 – 600 F N G 1 B 2 J Z 3 M 4 5 6 VDC Voltage Code 24 48 110 125 220 440 Y W P Q R T Consult factory if other voltages are required. Consult factory if other voltages are required. Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule AB 1.27 AC 1000 - 11/03 1 1 e lin e th rs ss acto o r t Ac con 1 Accessories for A/AE/AL/AF contactors Connection kits for reversing Catalog number Mounting on 3 pole contactors BEM... A1 A2 1 3 5 1 3 5 2 4 6 2 4 6 BEM circuit diagram A2 A/AE/AL9 – A/AE/AL16 A/AE/AL26 A/AE/AL30, A/AE/AL40 BEM16-30 BEM26-30 BEM40-30 $ 23 30 45 A/AE/AF50 – A/AE/AF75 A/AE/AF95, A/AE/AF110 A/AF145 – A/AF185 A/AF210 – A/AF300 BEM75-30 BEM110-30 BEM185-30 BEMA300-30 165 180 260 470 AF400 – AF460 AF580 – AF750 BEM460-30 BEM750-30 850 1200 Application Connections between the main poles of two 3 pole contactors mounted side by side so that they operate as reversing contactors. Description The connection kits for reversing contactors are made up of three reversing connections and three phase to phase connections. BEM16-30 — Insulated, solid, rigid copper wires BEM26 and 40-30 — Insulated, stranded, rigid copper wires BEM75 and 110-30 — Insulated, solid copper bars BES... A1 A2 A1 List price A1 1 3 5 1 3 5 2 4 6 2 4 6 Connection kits for phase to phase A2 Catalog number Mounting on 3 pole contactors A/AE/AF50, A/AE/AF75 A/AE/AF95, A/AE/AF110 A/AF145 – A/AF185 A/AF210 – A/AF300 BES110 connection diagram AF400 – AF460 AF580 – AF750 List price BES75-30 BES110-30 BES185-30 BESA300-30 $ 75 90 130 200 BES460-30 BES750-30 425 650 Catalog number List price The connection kit for phase to phase contactors is made up of three phase to phase bus bars. Connection kits for wye-delta starters Mounting on contactors BED... Line and delta contactor Wye contactor A30 A40 A26 A26 BED40U $ 53 A50 A63 A30 A40 BED50U 165 A75 A95 A110 A145 A185 A210 A50 A75 A95 A110 A145 A185 BED75U BED95U BED110U BED145U BED185U BED210U 180 195 225 250 290 375 A260/A300 A210 BED300U 500 AF400/AF460 A260/A300 BED400U 850 AF460 AF400 BED460U 900 AF580 AF400/AF460 BED580U 1250 AF750 AF580 BED750U 1450 Application Connections between the main poles of a wye-delta starter. Description The connection kits for wye-delta starters are made up of: • Three line contactor/wye contactor connections — line side. • Three wye contactor/delta contactor connections — load side. • The shorting connection for the “S” contactor. BED40U – Insulated, stranded, rigid copper wires. BED50U thru BED750U — Insulated, solid copper bars. The above connection sets allow a mechanical interlock unit to be mounted between the wye and delta contactors if required. 1.28 AC 1000 - 11/03 Discount schedule ABA Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Ac ro co ss nt the ac to line rs Accessories for A/AE/AL/AF contactors 1 Additional terminal blocks Wire range Mounting on 3 pole contactors A/AE/AL9 – A/AE/AL16 (set of 2) A/AE/AL26 (set of 2) A/AE/AL30 – A/AE/AL40 A/AE/AF50 – A/AE/AF75 A/AE/AF95 – A/AE/AF110 16 – 6 14 – 6 12 – 4 10 – 2 8–1 Catalog number List price LD-16 LD-26 LD-40 LD-75 LD-110 $ 20 22 26 28 30 Utilization – The LD series terminal block is designed to increase the connection capacity of the contactor on which it is mounted. The LD 75 and LD110 terminal blocks are mounted in the three independ apertures located above the built-in connectors. Terminal extensions Mounting on contactors A/AE/AF50 – A/AE/AF75 A/AE/AF95, A/AE/AF110 A/AF145 – A/AF185 A/AF210 – A/AF300 AF400 – AF460 AF580 – AF750 LD110 Catalog number List price BEXT-75 LW-110 LX185 LX300 $ 15 15 90 140 LX460 LX750 195 225 Application They are designed to increase the width of the contactor terminal pads to allow larger connectors to be mounted. Description Terminal extension sets contain 3 bars. Terminal shrouds — two pieces For contactor BEXT-75 LX... A/AF145 A/AF145 A/AF145 A/AF210 A/AF210 A/AF210 – – – – – – A/AF185 for flush mount A/AF185 for extended mount A/AF185 for shorting bar LY...between A(F)145 / A(F)185 & TA200DU A/AF300 for flush mount A/AF300 for extended mount A/AF300 for shorting bar LY300 LT185-AC LT185-AL LT185-AY LT300-AC LT300-AL LT300-AY AF400 AF400 AF580 AF580 – – – – AF460 for flush mount AF460 for extended mount AF750 for flush mount AF750 for extended mount LT460-AC LT460-AL LT750-AC LT750-AL List price $ 10 20 Terminal enlargements For contactor A/AF95 A/AF145 A/AF210 AF400 AF580 LT185-AC Catalog number – – – – – A/AF110 A/AF185 A/AF300 AF460 AF750 Catalog number LW110 LW185 LW300 LW460 LW750 List price $ 95 120 130 295 355 Arc chutes For contactor A/AF145 A/AF210 A/AF400 A/AF580 – – – – A/AF185 A/AF300 A/AF460 A/AF750 Catalog number ZW185 ZW300 ZW460 ZW750 List price $ 130 180 190 230 LT185-AL LW... Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule ABA 1.29 AC 1000 - 11/03 1 1 e lin e th rs ss acto o r t Ac con 1 Accessories for A/AE/AF contactors Vertical connection bars between contactor and MCCB — three bars MCCB BEA185/S3/S4 Catalog number For contactor T3 S3, S4 S4 S5 S51 S6 A/AF145 A/AF145 A/AF210 A/AF210 AF400 AF400 – – – – – – A/AF185 A/AF185 A/AF300 A/AF300 AF460 AF750 BEA185/T3 BEA185/S3/S4 BEA210/S4 BEA300/S5 BEA400/S5 BEA750/S6 List price $ 60 60 70 75 95 115 Vertical connection bars between contactor and MCCB — three bars MCCB S3, S4 S4 S5 S5 S6 BEAD185D/S3/S4 Catalog number List price BEA185D/S3/S4 BEA210D/S4 BEA300D/S5 BEA400D/S5 BEA750D/S6 $ 70 80 85 105 125 For contactor A/AF145 A/AF210 A/AF210 AF400 AF400 – – – – – A/AF185 A/AF300 A/AF300 AF460 AF750 To be used when power take off is needed (IP00) or with other bus bars. (EX: Reversing, IP20) Horizontal connection busbars between contactor and MCCB — three bars MCCB BEA185H/S4 Catalog number For contactor List price S3, S4 S4 S5 A/AF145 – A/AF185 A/AF210 – A/AF300 A/AF210 – A/AF300 BEA185H/S4 BEA210H/S4 BEA300H/S5 $ 150 220 220 S5 S6 S6 AF400 – AF460 AF400 – AF460 AF580 – AF750 BEA400H/S5 BEA460H/S6 BEA750H/S6 435 660 670 Shorting bars, 2 pole Catalog number For contactor List price A/AF145 – A/AF185 A/AF210 – A/AF300 LP185 LP300 $ 35 50 AF400 – AF460 AF580 – AF750 LP460 LP750 50 50 LP185 Shorting bars, 3 pole Catalog number For contactor A/AE45 – A/AE/AF75 LF75 List price $ 40 A/AE/AF95 – A/AE/AF110 A/AE/AF145 – A/AE/AF185 A/AE/AF210 – A/AE/AF300 LY110 LY185 LYA300 40 40 60 AF400 – AF460 AF580 – AF750 LY460 LY750 60 60 LY... Vertical connection bars between contactor and disconnect switch Disconnect switch For contactor Catalog number List price OS160 OESA250 OESA250 - OESA400 A/AF145 A/AF185 A/AF210 - A/AF300 OSZA15 BEF185V/OESA250 BEF300V/OESA400 $ 200 260 270 OESA400 OESA630 - OESA800 AF400 - AF460 AF460 - AF750 BEF460V/OESA400 BEF750V/OESA800 300 320 Horizontal connection bars between contactor and disconnect switch Disconnect switch For contactor Catalog number List price OESA250 OESA250 - OESA400 A/AF145 - A/AF185 A/AF210 - A/AF300 BEF185H/OESA250 BEF300H/OESA400 $ 515 595 OESA400 AF400 - AF460 BEF460H/OESA400 615 1 Not for use with flange handles. 1.30 AC 1000 - 11/03 Discount schedule ABA Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Ac ro co ss nt the ac to line rs Accessories for A contactors TE5S electronic timer for wye-delta starters 1 Electronic timer For contactors Rated control voltage Uc V Packing piece Unit weight kg Catalog number List price A9 – AF750 24 AC/DC 110 – 115 AC 220 – 230 AC 1 1 1 0.080 0.080 0.080 TE5S-24 TE5S-115 TE5S-230 $ 120 Application Utilization When used in wye-delta starters, the TE5S lags the wye connection and provides a lapse of 50 ms before the switchover to the delta connection. Description TE5S-* According to the type of device chosen, the electronic circuit has a 24 VAC/VDC, 110 – 120 VAC or 220 – 230 VAC supply. An output relay with reversing contact ensures high current switching. A two-position switch allows selection of one of the two time delay ranges: 0.8 to 8 s or 6 to 60 s. The 0.1 to 1.0 adjustable knob allows an initial setting without steps within the previously selected range which can then be adjusted using a stopwatch. U Note: We recommend that you allow for temperature drift for the final adjustment of the time delay setting. Drift: – 0.2% per °C. For example, a setting made at 20 °C will yield a time delay shorter by 7% at 55 °C in an enclosure. ( – 0.2% per °C i.e. – 0.2 x 35 = – 7%). 15-16 R 15-18 t1 t2 = 50ms Operation 15 A1 Chart t1 18 16 On energization, the green U indicator light (voltage applied) comes on. Contact 15 – 16 then immediately moves to the closed position. Count-down of the programmed time immediately commences. t1+t2 A2 TE 5S The TE5S, which is not affected by these settings, establishes a fixed “lapse” of 50 ms between the opening of contact 15 – 16 and the closing of contact 15 – 18. It is this time delay that prevents from arc short-circuit during wye to delta switching. Equivalent diagram When the time delay has elapsed, contact 15 – 16 opens and at the same time the 50 ms lapse, t2, begins after which contact 15 – 18 moves to the closed position. The yellow R indicator light comes on. On de-energization, the U and R indicator lights go out and, after the 250 ms resetting time, the device is ready for a new cycle. Mounting Mounts on 35mm DIN rail. A1 15 TE5S U 0.5 0.1 1.0 0.8 ... 8s t1 6 ... 60s R Star-Delta Timer 16 18 A2 Front face Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Discount schedule ABA 1.31 AC 1000 - 11/03 1 1 e lin e th rs ss acto o r t Ac con 1 Accessories for A contactors TE5S electronic timer for wye-delta starters Technical data Type TE5S-24 Compliance with standards TE5S-115 Rated insulation voltage Ui according to IEC 947-5-1 V Rated supply voltage Uc VDC VAC Rated frequency limits 250 24 24 Hz — 110 – 115 0.85 – 1.1 Uc Overvoltage protection Built-in varistor Load factor % Average consumption in DC in AC W VA Time delay range (t1 ) selected by switch S Temperature drift % per °C 100 0.7 1.5 — 3.5 - 0.2 ± 15% of the setting range On-load reiteration accuracy under constant conditions ± 2% after 1 million operations Minimum time lapse (t2 ) Min. time lapse after 1 million operations Resetting time (maximum) ms 50 ms 40 ms 250 green indicator light yellow indicator light Energization Output relay activated Rated operational voltage Ue acc. to IEC 947-5-1 VDC VAC 24 24 – 230 Conventional free air thermal current Ith A 10 Rated operational current Ie acc. to IEC 947-5-1 DC-13 24 VDC A 4 A A 5 4 °C °C -25 … +60 -40 … +85 24 – 115 VAC 220 – 230 VAC Permissible air temperature for operation for storage Mechanical durability in millions of operations 5 Electrical durability in millions of operations 1 On-load maximum switching frequency ops./h Shock and vibration withstand 35 x 7.5 or 35 x 15 Connecting terminals (+,-) pozidriv 1 screw Tightening torque Flexible without cable end 720 on request Fixing on mounting rail according to EN 50022 Connecting capacity Rigid solid — 6.5 0.8 – 8 and 6 – 60 Mechanical setting accuracy Front panel display: — 220 – 230 48 – 63 Supply voltage range AC-15 TE5S-230 IEC 947-5-1, EN 60947-5-1 and VDE 0435 N.m 0.6 – 0.8 max. 1 or 2 x mm2 1 – 2.5 1 or 2 x mm2 0.75 – 2.5 Degree of protection acc. to IEC 529, IEC 947-1 and EN 60 529 1.32 AC 1000 - 11/03 Housing IP 50 Terminals IP 20 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Ac ro co ss nt the ac to line rs Accessories Terminal markings CA/CC/CAL/CCL auxiliary contacts 1 One pole auxiliary contacts -3 -1 -3 -1 NO NC NO NC -4 -2 -2 -4 CA5-01 CA5-10 CE5-10 CE5-01 -7 -5 NO NC -8 -6 CC5-10 CC5-01 Two pole auxiliary contacts 83X 13X 21X 31X 72X / 84X / CAL5-11B (R. h. s. mounted) 18X 26X 25X 48X / 17X 43X 36X 48X 35X 47X 14 NO NO NC 36X / 71X 44X 13 47X / 62X / 83X / NC 61X 35X / CCL5-11 (L. h. s. mounted) NO 54X / 71X / NC CAL5-11B (L. h. s. mounted) CAL5-11 (R. h. s. mounted) NC 26X / 44X / 61X / NO NO 53X 32X 25X / NO 18X / 22X 17X / 14X 32X / CAL5-11 (L. h. s. mounted) 53X / 84X 22X / 43X / NC 72X 14X / 31X / NC 62X 21X / NO 54X 13X / CCL5-11 (R. h. s. mounted) 21 31 NC NC 22 32 CAL16-11 A 53 61 71 83 35 47 NO NC NC NO NC NO 54 62 72 84 36 48 43 NO 44 CAL16-11 B CAL16-11 C CAL16-11 D CCL16-11 E Four pole auxiliary contacts 11 21 31 41 21 31 41 51 51 61 71 81 NC NC NC NC NC NC NC NC NC NC NC NC 12 22 32 42 22 32 42 52 52 62 72 82 CA5-04 E 13 NO 14 21 31 NC NC 22 32 43 NO 44 13 14 21 NC 33 NO 22 34 43 NO 44 13 14 23 NO 24 31 NC NC 22 32 43 NO 53 NO 54 44 21 NC 22 33 NO 43 NO 34 33 NO 34 53 NO 44 54 13 14 54 51 NC 52 53 43 — NO 61 71 NC NC 62 72 83 NO 84 63 NO 73 NO 64 83 NO 74 84 CA5-31 N NO 54 44 63 NO 73 NO 64 74 83 NO 84 CA5-40 N CA5-40 E NO 53 NO CA5-22 N CA5-31 M CA5-31 E NO 21 CA5-22 M CA5-22 E NO CA5-04 N CA5-04 M 21 35 NC NC 22 36 CA5-11/11 E 47 NO 48 21 NC 22 33 NO 34 45 NC 57 NO 46 58 CA5-11/11 M Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com 1.33 AC 1000 - 11/03 1 1 e lin e th rs ss acto o r t Ac con 1 Accessories Terminal markings & positioning for A/UA contactors Standard devices without addition of auxiliary contacts A2 A1 A2 A1 A1 1L1 3L2 5L3 21 1L1 3L2 5L3 13 NC NO NC NO 2T1 4T2 6T3 22 2T1 4T2 6T3 14 A2 R3 R4 2 3L2 4T2 2T1 8 R6 5L3 1L1 3L2 5L3 A2 2T1 4T2 6T3 21 NC 4T2 6T3 NC 22 A9 – A40-30-01 A50 – A110-30-00 UA50 – UA110-30-00 A1 1L1 3L2 5L3 A2 2T1 4T2 6T3 13 NO NO 14 A9 – A40-30-10 A1 1L1 3L2 5L3 A2 2T1 4T2 6T3 A50 – A110-30-00 UA50 – UA110-30-00 7L4 5L3 A1 1 R3 R5 7 A2 2 R4 R6 8 A1 1L1 3L2 5L3 7L4 A2 2T1 4T2 6T3 8T4 8T4 6T3 A2 A2 A9 – A26-40-00 A45 – A75-40-00 A9 – A26-22-00 A45 – A75-22-00 A9 ... A26-40-00 A45 ... A75-40-00 A9 – A26-22-00 A45 – A75-22-00 A1 A2 A1 1L1 7 R5 A2 A2 A9 – A40-30-10 A2 A1 2T1 A2 A9 – A40-30-01 1 3L2 1L1 Standard 3 pole devices with factory mounted auxiliary contacts A2 A1 A1 1L1 3L2 5L3 13 21 NO NC 14 22 31 3L2 1L1 43 13X 43X 21X 31X 22X 32X 32 44 1L1 3L2 5L3 13 NO 21 NC 31 NC 43 NO 6T3 A2 2T1 4T2 6T3 NO 14 NC 22 NC 32 NO 44 A2 A9 – A16-30-22 A50 – A110-30-22 44X 14X 4T2 2T1 A2 A9 – A16-30-22 Combination 22 2 A1 A2 A1 1L1 3L2 5L3 13 31 A1 NC NO 2T1 4T2 6T3 21 A2 5L3 43 3L2 1L1 NO 53 A2 5L3 NO 13X NC 21X NC NC NO NO A1 NC 22X 22 32 44 54 NO 1L1 3L2 5L3 13 NO 21 NC 31 NC 43 NO 53 NO NO 14 NC 22 NC 32 NO 44 NO 54 4T2 2T1 2T1 4T2 6T3 14 6T3 A2 A2 A2 2T1 4T2 6T3 A9 – A40-30-32 A50 ... A110-30-11 UA50 ... UA110-30-11 A9 – A40-30-32 A2 A1 A1 1L1 3L2 A2 1L1 3L2 5L3 13 1L1 3L2 5L3 13 NO NO A2 = + 2- NO NO 2T1 4T2 6T3 14 2T1 4T2 6T3 14 A2 5L3 13 2- 21 = 2- 6- 14 22 A1 5L3 43 1L1 3L2 NO NO 2T1 4T2 6T3 14 A2 44 43X NO NC 21X 4T2 6T3 A2 A50 – A110-30-22 = 1.34 AC 1000 - 11/03 6T3 31X NC + NC 22X 32X NC NO 14X 44X NO 2T1 4T2 NO 14X NC 22X A1 1L1 3L2 5L3 13 NO 21 NC A2 2T1 4T2 6T3 NO 14 NC 22 A9 – A40-30-10 + CA5-01 + CA5-10 A2 3L2 1L1 1L1 3L2 5L3 13 NO 21 NC 33 NO A2 2T1 4T2 6T3 NO 14 NC 22 NO 34 Combination 21 A1 1L1 3L2 A2 2T1 NO NC NC 4T2 6T3 14X 22X 32X 5L3 A2 A1 7L4 5L3 A1 3L2 13X 21X 31X 43X NO NC NC NO 7L4 5L3 A2 = 5- = 6- 13 2- 3- 4- 5NO 6- 14 2- 3- 4- 5- 2T1 4T2 6T3 6- 1- 2- 3- 4- 5- + = 6- 1- 2- 3- 4- 5- 8T4 2T1 A2 2T1 -3 NO -4 + 5L3 5- NC NO 32 3- 2T1 4T2 6T3 14 Combination 21 A9 – A40-30-10 + CA5-01 A2 31 -1 NC -2 + A2 NO 13X 13 3- = A1 NO NC NO 21 33 NC NO 22 34 -1 NC -2 1L1 6- 2T1 4T2 5L3 13 A2 Combination 11 3L2 A2 13X 21X NO NC Combination 11 2- 21 NC 22 A1 5L3 A2 A1 1L1 3L2 NO 1L1 1L1 3L2 A50 – A110-30-11 UA50 – UA110-30-11 Other possible contact combinations with auxiliary contacts added by the user A1 A1 NO 14X 4T2 6T3 -3 NO -4 Combination 22 A1 1L1 3L2 5L3 7L4 13 NO A2 2T1 4T2 6T3 8T4 NO 14 8T4 A2 6T3 A2 A50 – A75-30-11 + CAL5-11 Combination 10 NO 44X = A45 – A75-40-00 + CA5-10 Combination 10 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com Ac ro co ss nt the ac to line rs Accessories Terminal marking and positioning for AE/AL contactors AE Contactors — D.C. operated 3L2 3L2 1L1 5L3 A2 A1 A2 A1 A2 A1 1L1 3L2 1L1 5L3 VDC 5L3 NC 21X NC 22X 1L1 3L2 A1 AE50 – AE75-30-00 3L2 1L1 A2 A1 R3 1 5L3 1L1 3L2 NC 22X NC 22X 4 T2 5 L3 6 T3 Coil wiring A1 1 R3 R5 7 A2 2 R4 R6 8 VDC { A1 A2 A3 U 7L4 5L3 C D L 5 C C L 5 36 X 2 T1 3 L2 AE50 – AE110-30-11 NO 13X NC 21X NO 14X 6T3 1 L1 A2 A1 7 R5 2T1 4T2 A2 AE95 – AE110-30-00 AE50 – AE75-30-11 A2 A1 A3 A3 A3 A3 U 13X 21X NO NC 5L3 4T2 6T3 2T1 6T3 4T2 2T1 4T2 6T3 A1 A2 35 X NO 14X 2T1 { AE50 – AE110-30-00 C C L 5 C D L 5 6T3 2T1 4T2 A2 NO 13X C D L 5 5L3 1L1 3L2 A1 1 15 X 16 X AE45 – AE75-22-00 C D L 5 A1 1L1 3L2 5L3 7L4 A2 2T1 4T2 6T3 8T4 1 L1 2 T1 7 L4 8 T4 NO 14X 4T2 2T1 6T3 R4 2 8 R6 A3 2T1 4T2 AE95 – AE110-30-11 8T4 6T3 A3 A3 AE45 – AE75-22-00 AE45 – AE75-40-00 Coil wiring AE45 – AE75-40-00 AL Contactors — D.C. operated Standard devices without addition of auxiliary contacts A1 A1 1L1 3L2 5L3 21 1L1 3L2 5L3 13 NC NO NC NO 2T1 4T2 6T3 22 2T1 4T2 6T3 14 A1 A2 A2 AL9 – AL40-30-01 A1 1 R3 A2 AL9 – AL40-30-10 R4 3L2 5L3 2T1 4T2 6T3 A1 21 NC NC 22 A2 1L1 3L2 5L3 2T1 4T2 6T3 13 NO NO 14 AL9 – AL40-30-10 AL9 – AL40-30-01 A1 R5 7 1L1 3L2 5L3 7L4 A1 2 1L1 R6 8 1 R3 R5 7 A1 2 R4 R6 8 A2 1L1 3L2 5L3 7L4 2T1 4T2 6T3 8T4 2T1 4T2 6T3 8T4 A2 A2 AL9 – AL26-22-00 A2 AL9 – AL26-40-00 AL9 – AL26-40-00 AL9 – AL26-22-00 Other possible contact combinations with auxiliary contacts added by the user A1 A1 1L1 3L2 5L3 13 1L1 3L2 5L3 13 NO 21 33 NC NO 22 34 NO 2- 3- 4- 5- 2- 3- 4- 5- = + NO NO 2T1 4T2 6T3 14 2T1 4T2 6T3 14 A2 Combination 21 -1 NC -2 + -3 NO -4 A2 = AL9 – AL40-30-10 Low Voltage Products & Systems ABB Inc. • 888-385-1221 • www.abb-control.com + CA5-01 + CA5-10 A1 1L1 3L2 5L3 13 NO 21 NC 33 NO A2 2T1 4T2 6T3 NO 14 NC 22 NO 34 Combination 21 1.35 AC 1000 - 11/03 1