1 - Galco Industrial Electronics

advertisement
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
1
Accessories
for A/AF/AL & AE contactors
Auxiliary contact blocks – Standard
Maximum number
of contact blocks
Positioning
4 blocks: A9 – A26
AE9 – AE26
Front mounting
AL9 – AL26
(single pole) 5 blocks: A30, A40, AE30, AE40, AL30, AL40
6 blocks: A45 – A110
AE45 - AE110
AF45 - AF110
CAL5-11
CA5-10
A9 – A26-40-00
A30 – A110
Front mounting 1 block:
AE9 – AE110
(4 pole)
1 block: A9 – A40-30-10
AL9 – AL40-30-10
2 blocks: A9 – A75, AE9-AE45
1 block: AE50 – AE75, AL9 – AL40
Side mounting 1 block: AE95 - AE110
(2 pole)
2 blocks: A145 – A300, AF145-AF1650
2 blocks: A145 – A300, AF145-AF1650
Contact
Description
Catalog
number
1 N.O.
1 N.C.
CA5-10
CA5-01
1 N.O. Early make
1 N.C. Late break
CC5-10
CC5-01
4 N.O.
3 N.O. & 1 N.C.
2 N.O. & 2 N.C.
4 N.C.
2 N.O./2 N.C.1
CA5-40E
CA5-31E
CA5-22E
CA5-04E
CA5-11/11E
3 N.O. & 1 N.C.
2 N.O. & 2 N.C.
1 N.O. & 3 N.C.
4 N.C.
4 N.O.
2 N.O./2 N.C.1
CA5-31M
CA5-22M
CA5-13M
CA5-04M
CA5-40N
CA5-11/11M
1 N.O. & 1 N.C.
CAL5-11
1 N.O. & 1 N.C.
CAL18-11
List
price
$ 15
30
1 N.O. & 1 N.C. (inside L or R)
CAL18-11
1 N.O. & 1 N.C. (outside, L or R) CAL18-11B
Auxiliary contact blocks – Front mounting, switching low voltage and low current
Positioning
Front mounting
(single pole)
Maximum number
of contact blocks
Contact
Description
Degree of
protection
Catalog
number
List
price
4 blocks: A9 – A26
AE9 – AE26
AL9 – AL26
1 N.O.
1 N.C.
1 N.O.
1 N.C.
IP40
IP40
IP40
IP40
CE5-10D0.1
CE5-01D0.1
CE5-10D2
CE5-01D2
$ 38
5 blocks: A30, A40, AE30, AE40, AL30, AL40
6 blocks: A45 – A110
AE45 - AE110
AF45 - AF110
1 N.O.
1 N.C.
1 N.O.
1 N.C.
IP67
IP67
IP67
IP67
CE5-10W0.1
CE5-01W0.1
CE5-10W2
CE5-01W2
42
1 Includes 1 N.O. & 1 N.C. overlapping
1.16
AC 1000 - 11/03
Discount schedule ABA
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
ro
co ss
nt the
ac
to line
rs
Accessories
for A/AF/AL & AE contactors
1
Pneumatic timers
Mounting
on
Timing
range
A9 – A75
AE9 – AE75
AL9 – AL40
On delay 0.1 – 40 s
On delay 10 – 180 s
Off delay 0.1 – 40 s
Off delay 10 – 180 s
Contacts
N.O. N.C.
1
1
1
1
1
1
1
1
Catalog
number
TP40DA
TP180DA
TP40IA
TP180IA
List
price
$ 108
Interlocks for two horizontally mounted contactors – A9 - A110
TP40DA
Feature
Mounting
on
Mechanical/electrical
Mechanical/electrical
Mechanical
A/AE/AL9 – A/AE/AL40
A45 – A110
A/AE/AL9 – A/AE/AL40
Contacts
N.O. N.C.
—
—
—
2
2
—
Catalog
number
VE5-1
VE5-2 1
VM5-1
List
price
$ 45
45
21
Interlocks for two horizontally mounted contactors – A95 - AF750 contactors
Left
contactors
Right
contactors
A95 – A300
A210 – A300
AF400 – AF750
A145 – A300
AF400 – AF460
AF400 – AF750
Feature
Mechanical
Mechanical
Mechanical
VE5-1
Catalog
number
VM300H
VM300/460H
VM750H
List
price
$ 110
130
150
Interlocks for two vertically mounted contactors – A95 - AF750 contactors
Top
contactor
Feature
Mechanical
Mechanical
Mechanical
VM300H
A95 – A300
A210 – A300
AF400 – AF750
Mounting
on
Connects from side
Connects from top
Connects from side
LK75-A1
A145 – A300
AF400 – AF460
AF400 – AF750
Catalog
number
VM300V
VM300/460V
VM750V
List
price
$ 205
250
270
Auxiliary lead terminals (Set of 2)
Connections
LK75-A
Bottom
Contactor
A50 – A75
A50 – A75
A95 – A110
Catalog
number
LK75-A
LK75-A1
LK110
List
price
$ 15
15
23
LK110
1 Use type VE 5-2 for mechanical and electrical interlocking between A30/A40 and A50 - A75 contactors.
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule ABA
1.17
AC 1000 - 11/03
1
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
1
Positioning
Accessories
Possible accessory combinations for A contactors
Accessories — Front face mounting
Top
Auxiliary contacts
1 – pole
4 – pole
Front
face
Left
side
CA5-10
or CA5-01
CA5-40
or CA5-22
or CA5-31
Accessories — Side mounting
Pneumatic
timers
Auxiliary
contacts
TP – D
or TP – I
CAL 5-11
CAL18-11
CAL18-11B
Electrical or
mechanical interlock1
VE5-1
or VM 5-1
VE 5-2
VM300H
VM300/460H
VM750H
Configurations of accessories are different depending on whether front or side mounted.
N Contactor relays
A and AE Contactors
Accessories — Front mounting
Auxiliary contact blocks
TP - A Pneumatic
1-pole CA54-pole CA5timer block
Type
Main
poles
Built-in
auxiliary
contacts
A9 – A26
A9 – A26
A9 – A26
A9 – A26
AE9 – AE26
AL9 – AL26
–
–
–
–
–
–
–
–
–
–
–
–
A9 – A16
A9 – A26
– 3 0 – 2 2
– 3 0 – 3 2
—
A30, A40
AL30, AL40
A30, A40
AL30, AL40
AE30, AE40
–
–
–
–
–
1 to 5 CA5-
A30, A40
– 3 0 – 3 2
A50 – A75
A45 – A75
A45, A75
A95, A110
–
–
–
–
A50 – A75
A95, A110
– 3 0 – 2 2
– 3 0 – 2 2
AE50 – AE75
AE45 – AE75
AE45, AE75
AE95, AE110
–
–
–
–
3
4
2
3
0
0
2
0
–
–
–
–
0
0
0
0
0
0
0
0
A50 – A75
AE50, AE75
A95, A110
AE95, AE110
–
–
–
–
3
3
3
3
0
0
0
0
–
–
–
–
1
1
1
1
1
1
1
1
3
3
4
2
3
3
3
3
3
3
3
3
4
2
3
0
0
0
2
0
0
0
0
0
0
0
0
0
2
0
–
–
–
–
–
–
–
–
–
1
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
1
0
0
0
0
1
A145 – AF1650 – 3 0 – 0 0
OR 1 CA54-pole block
+
1 to 2
CAL5-11 blocks
OR 1 VM/E 5-1 block
+ 1 CAL5-11 block
—
+
1 to 2
CAL5-11 blocks
OR
1 TP - A block
+
1 to 2
OR 1 VM/E 5-1 block
OR 1 TP - A block
1
0
0
1
1
0
0
0
0
0
1 to 4 CA51-pole blocks
Accessories — Side mounting
Auxiliary contact Blocks
Interlock units
2-pole CAL5-11,
CAL18-11
—
OR
OR
1-pole blocks
+ 1 CA5- 1-pole block
+ 1 CA5- 1-pole block
CAL5-11 blocks
+ 1 CAL5-11 block
1 CA51-pole block
—
—
+
1 to 2
CAL5-11 blocks
OR 1 VM/E 5-1 block
+ 1 CAL5-11 block
1 to 6 CA51-pole blocks
1 CA5- 4-pole block
+ 2 CA5- 1-pole blocks
+
1 to 2
1 VE5-2 block
OR + 1 CAL5-11 block
CAL5-11 blocks
2 CAL18-11 blocks
1 VE5-2 + CAL5-11
+
1 to 2
CAL5-11 blocks
1 VE5-2 block
OR + 1 CAL5-11 block
+
1 CAL5-11 block
1 CAL5-11 block
1 CAL5-11 block
1 CAL18-11 block
OR
1 CAL5-11 block
—
1 CAL18-11 block
—
1 VE5-2 block
OR —
1 VE5-2 block
OR —
2
OR
2 CA51-pole blocks
2
1 CA5- 4-pole block
1 VM/E 5-1 block
+ 1 CAL5-11 block
OR
1 to 6 CA51-pole blocks
OR
—
OR
—
1 to 6 CA51-pole blocks
1 CA5- 4-pole block
+ 2 CA5- 1-pole blocks
1 CA5- 4-pole block
+ 2 CA5- 1-pole blocks
—
1 TP - A block
+ 2 CA51-pole blocks
—
—
OR
1 TP - A block
+ 2 CA51-pole blocks
—
OR
1 TP - A block
+ 2 CA51-pole blocks
—
—
+
1 VE5-2 block
1 to 2
1 CAL18-11 block
+ 1 CAL18-11B block
CAL18-11 blocks
OR + VM300H or VM300/460H
+ 1 to 2
CAL18-11B blocks
or VM750H interlock
Contactor mounting configurations (standard from factory)
Auxiliary contacts are mounted on the contactor in the following order:
Left – 1st
Right – 2nd
Top – 3rd (L to R)
1 In mounting position 5 (see page 1.36), there should be no more than 2 "N.C." front-mounted auxiliary contacts – The CAL 5-11 side-mounted blocks offer additional "N.C." contacts.
2 Whatever the mounting position (see page 1.36), there should be no more than 2 "N.C." front-mounted auxiliary contacts – The CAL 5-11 side-mounted blocks offer additional "N.C." contacts.
1.18
AC 1000 - 11/03
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
ro
co ss
nt the
ac
to line
rs
Accessories
Auxiliary contact block technical data
CA5/CAL5-11/CAL18-11/CC5
Types
1-pole CA5, 4-pole CA5
2-pole CAL5-11 and 1-pole CC5
1
CAL18-11
CAL18-11B
IEC 947-5-1 and EN 60947-5-1
Standards
Rated insulation voltage Ui
according to IEC 947-5-1
according to UL/CSA
690
600
V
V
Rated operational voltage Ue
690
690
24 to 690
~V
A
16
24 to 127 V
220 to 240 V
380 to 440 V
500 to 690 V
A
A
A
A
6
4
3
2
24 V
48 V
72 V
125 V
250 V
A
A
A
A
A
6
2.8
1
0.55
0.3
Conventional thermal current Ith
Rated operational current Ie
in AC-15 acc. to IEC 947-5-1
in DC-13 acc. to IEC 947-5-1
M 3.5 (+,-) pozidriv 2 screw
with cable clamp
Connecting terminals
(delivered in open position. Screws of unused terminals should be tightened).
Connecting capacity
• Rigid solid
1 or 2 x mm2
1 to 4
1 x mm2
2 x mm2
• Flexible with cable end
0.75 to 2.5
0.75 to 2.5
cycles
Mechanical durability
Max. switching frequency
Electrical durability
Max. switching frequency
10 million, A9 - A75;
3 million, A95 & A110;
5 million, A/AF95 - A/AF185;
3 million, A/AF210 - AF750;
0.5 million, AF1350 & AF1650
cycles/h
3600
cycles/h
See curve below
1200
10 x Ie AC-15
10 x Ie AC-15
Rated making capacity
Rated breaking capacity
1s
0.1 s
Rated short-time withstand current Icw
q = 40°C
100
140
A
A
17 V / 5 mA, A9 - A75;
24V / 50 mA, A95 & A110
Min. switching capacity
24V / 50 mA
Short-circuit protection - gG (gl) fuses
A
10
Power loss per pole at 6 A
W
0.15
Degree of protection according to IEC 529,
IEC 144, DIN 40 050 and NFC 20-010
IP 20
CAL18
CA5, CAL5
Million ops.
30
30
20
20
10
10
5
Million ops
A/AF95...A/AF185 5
A/AF210...AF750
3
2
1
AF1350/AF1650
0.5
2
1
0.5
0.3
0.2
0.1
0.02
CA 5, CAL 5
3
0.3
0.2
0.05
0.1
0.2 0.3
0.5
1
2
3 4 5 6
Breaking current (A)
10
0.1
0.02
0.05
0.1
0.2 0.3
0.5
1
2
3
4 5 6
10
Breaking current (A)
Electrical durability
AC-15 according to IEC 947-5-1
making current: 10 x Ie where cos ϕ = 0.7 and Ue
breaking current:
Ie where cos ϕ = 0.4 and Ue
The curves opposite show the electrical durability of the auxiliary contact blocks
according to breaking current Ic.
These curves have been plotted for resistive and inductive loads up to 690 V,
40 to 60 Hz.
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
1.19
AC 1000 - 11/03
1
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
1
Accessories
Auxiliary contact block technical data
CE5
Auxiliary contact blocks for switching low level voltage and current
Types
CE5-10D0.1
CE5-01D0.1
CE5-10W0.1
CE5-01W0.1
CE5-10DZ
CE5-01DZ
CE5-10WZ
CE5-01WZ
Version 100 mA
Version 2 A
Standards
IEC 947-5-1 and EN 60947-5-1
Approvals
UL / CSA
Rated insulation voltage Ui
according to IEC 947-5-1
according to UL/CSA
V
V
250
125
250
250
Rated operational voltage Ue
V
125
250
A
A
A
A
A
0.1
0.1
0.1
0.1
0.1
2
2
0.5
0.2
0.1
Rated operational current Ie
in AC-15 or AC-14 acc. to IEC 947-5-1
in DC-12 acc. to IEC 947-5-1
24 V
60 V
110 V
220 V
3 V / 1 mA
Minimal switching
10
Reliability for the minimal switching
M3.5 (+,-) posidriv 2 screw with cable clamp
Connecting terminals
Connecting capacity
• Rigid solid
• Flexible with cable end
1 ou 2 (1...4) mm2
1 ou 2 (0.75... 2.5) mm2
100 mA
Short circuit protection
Degree of protection
according to IEC529, IEC 144, DIN 40 050, NFC 20-010
Mounting
Dimensions
1.20
AC 1000 - 11/03
17 V / 5 mA
-8
10 A
IP 20
Front mounting on contactors: A, AE, TAE9...110, AL, AF, GA, N, NE
Identical to those of CA5 single pole
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Accessories
Surge suppressors for A/AE/AL/EK contactors
Ac
ro
co ss
nt the
ac
to line
rs
1
Surge suppression device
Mounting
on
Voltage
range
AE9 to AE110
AL9 to AL40
A9 to A110; AE9 to AE110
AL9 to AL40
RV 5/50
A9 to A40
A45 to A300
RC 5-1/150
Catalog
number
12
25
50
77
150
–
–
–
–
–
32 VDC
65 VDC
90 VDC
150 VDC
264 VDC
RT5/32
RT5/65
RT5/90
RT5/150
RT5/264
24
50
110
250
–
–
–
–
50 VAC/VDC
133 VAC/VDC
250 VAC/VDC
440 VAC/VDC
RV5/50
RV5/133
RV5/250
RV5/440
24
50
110
250
–
–
–
–
50 VAC
133 VAC
250 VAC
440 VAC
RC5-1/50
RC5-1/133
RC5-1/250
RC5-1/440
24
50
110
250
–
–
–
–
50 VAC
133 VAC
250 VAC
440 VAC
RC5-2/50
RC5-2/133
RC5-2/250
RC5-2/440
EK110 to EK210
24 – 48 VAC
110 – 415 VAC
RC-EH250/48
RC-EH250/415
EK370 to EK550
48 – 110VAC
RC-EH800/110
EK110 to EK550
24 – 125VAC
RC-EH800/110
EK370 to EK550
220 – 600VAC
RC-EH800/600
List
price
$ 30
26
Technical data
Type
Control
circuit
Opening time
growth factor
Residual overvoltage
or clipping voltage
2.5 to 3
50 V
100 V
150 V
210 V
390 V
Advantages
RT 5 /... transil diode
32
65
90
150
264
Varistor
RV 5/...
50
133
250
440
RC 5-1/... or RC 5-2/...
RC-EH 300/...
Varistor + RC
Remarks
see table
above
DC
DC
DC
DC
DC
AC/DC
AC/DC
AC/DC
AC/DC
1.1 to 1.5
132 V
270 V
480 V
825 V
AC
RC-EH ...
800/110 AC/DC
800/600 AC
1.2 to 3
2 to 3 x Uc
1.1 to 1.5
205 V
1100 V
Drawback
•
•
•
•
Good energy absorption
Unpolarized system
Simple, reliable system
A certain delay on drop out which does not
however reduce contactor breaking capacity.
Advantages
• High energy absorption; good damping
• Unpolarized system
Drawback
• Clipping as from Uvdr, thus voltage front up to
this point
Advantages
• Very fast clipping
• Attenuation of steep fronts and thus of
high frequencies
• No operating delays
Advantages
• High energy absorption: good damping
• Unpolarized system
• The RC system damps the voltage
front under the Uvdr* threshold.
*Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ± 10%
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule ABA
1.21
AC 1000 - 11/03
1
1
Accessories
Surge suppressors for A/AE/AL/EK contactors
General information
General
U (V)
The operation of inductive circuits causes overvoltages, in particular on opening of the contactor coil.
1000
T (µs)
0
1000
0
100
100
The electromagnetic energy stored by the coil during contactor closing is restored on opening in the form of surges, the
slope and amplitude of which may rise to several kilovolts. A number of drawbacks are observed ranging from interference
on the electronic devices to breakdown of insulators and even destruction of certain sensitive components.
The graph opposite reproduces the oscillogram showing voltage discharges at the terminals of a 42V/50Hz coil without
peak clipping. The coil was switched by 8 series-connected poles of a contactor relay.
Following a burst of discharges with a very steep slope a damped oscillation emerges with a peak value of 3500V.
Overvoltage factor
The overvoltage factor k is defined as the ratio of the maximum overvoltage peak value Ûs to the peak value Ûc of the coil
rated control voltage Uc:
Ûs max.
k = _______
Ûc
in DC:
Ûs max.
k = _______
Uc
or in AC:
Ûs max.
k = _______
Uc√2
3500
For example the following is obtained for the above graph: k = _____ ≈ 60
42 √2
Surge suppressors
To guard against the harmful effects of these overvoltages, ABB has developed a range of surge suppressors designed to
reduce the k factor defined above and to limit or even completely eliminate the high pre-damping voltage frequencies.
Each case is different, but the technical data tolerances and the generous sizing of parts have enabled us to reduce the
number of variants.
We have chosen the following solutions: transil diodes, varistors and RC blocks.
Note: A varistor is a resistor whose value increases to a very large extent when a certain voltage is applied at its terminals.
Wiring diagrams
Transil diode
RC type
Varistor (only)
Varistor + RC
A1
A1
A1
A1
A2
A2
A2
A2
U
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
General technical data
The housings and impregnation resins of the surge suppressors are made of flame-resistant materials in accordance with
the UL 94 standard.
These systems are not polarized, i.e. d.c. operated devices do not have to be connected in a specific direction.
• Operating temperature: -20 to +70 °C
• Connection to the coil terminals (parallel mounting)
– For RT 5, RV 5, RC 5-1 and RC 5-2: clip-on for both fixing and connection.
• Mounting:
– RT 5, RV 5 and RC 5: clipped onto the top part of the contactor base. This mounting method prevents any
projections and change in contactor dimensions.
– RC-EH: glued to the top part of the contactor base.
1.22
AC 1000 - 11/03
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
ro
co ss
nt the
ac
to line
rs
Accessories
Interface relays for A contactors
1
Interface relays
Mounting on
contactor types
Coil
voltages
N, A9 – A110
24 – 250V, 50, 60 Hz
Catalog
number
List
price
RA5
$ 75
Description
RA5 interface relays are designed to receive 24 VDC signals delivered by PLCs or other sources with a low output power and
to restore them with sufficient power to operate the coils of the relevant contactors
Types
• RA5 for combination with A9 – A110 contactors and N contactor relays.
A30-30-10 + RA 5
Description
RA5 interface relays are made up of a miniature electromechanical relay equipped with a N.O. contact and with a low
consumption 24 VDC coil.
The interface relay coil is controlled by the PLC while the N.O. contact ensures switching of the power contactor.
Coil switching gives rise to overvoltages which have adverse effects on the electronic devices, insulators and, more generally,
on component lifetime. The RA 5 is equipped with surge suppressors:
• on the 24 VDC relay coil via a diode
• on the power contactor coil via a varistor.
RA 5
Furthermore, the RA5 are protected against relay pole reversal by a diode inserted between the E1 and E2 input terminals.
Connection
The “E1+” and “E2–” input terminals must be connected, according to their polarity, to the PLC output.
• The RA 5 is equipped with two terminal pads for connection to the A1 and A2 terminals of the contactor coil. This coil is
supplied between the A0 and A2 terminals of the RA 5.
RA 5 interface relay for the A 9 – A 110
contactors and N control relays
PLC
Output
A0
Uc
250 VAC
–
A2
E2 –
+
24 VDC
E1 +
RA 5
A1
KM1
A2
Mounting
• RA5: terminal pads clamped inside the contactor coil terminals.
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule ABA
1.23
AC 1000 - 11/03
1
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
1
Accessories
Interface relay technical data
General technical data
IEC 255-5
Standards
Rated insulation voltage Ui
acc. to IEC 947-4-1 and VDE 0110
VAC
Permissible ambient temperature
• For free air operation:
– at Ue = 24VDC (between E1 & E2)
– from 0.85 to 1.1 Ue
• For storage
°C
°C
°C
-25 to + 70
-25 to +55
-40 to +70
Complies with that of associated contactors
Climatic withstand
No limitation
Mounting position
meters
Operating height
3000
Using the contactor A1 and A2
terminal connecting points
Cable clamps and M 3.5 (+, –) pozidriv screws (2)
Mounting
Connecting terminals (open on delivery)
Cable cross-sectional area:
• Rigid solid
• Flexible
250
2 x mm2
2 x mm2
1 to 4
0.75 to 2.5
Protection against direct contact acc. to VDE 0106, Part 100
Degree of protection
Construction data
Surge suppression:
• For contactor coil
• For interface relay coil
Varistor
Diode
Diode
Protection against polarity reversal between terminals E1 and E2
Use on contactors with coils:
• 24 to 250V/50, 60 Hz
• 12 to 250VDC
Interface relay operating time
Total operating time, interface relay + contactor
• Between energization and:
– NO contact opening
– NC contact opening
• Between de-energization and:
– NO contact opening
– NC contact opening
types
types
ms
N, A9 – A110
AL9 – AL40
ms
ms
19 to 36
16 to 32
ms
ms
15 to 25
18 to 28
VDC
VDC
24
17 to 30
Electrical input data
Control voltage (E1 and E2 terminals) Uc:
• Rated value
• Maximum range
Max. consumption for Uc = 24 VDC, Ø=20°C
W
0.3
“0” status (relay open)
• For Uc
• For Ic
VDC
mA
≤ 2.4
≤1
“1” status (relay closed) for Uc
VDC
≥ 17
Max. short supply interruption immunity time
ms
4
Electrical output data
Switching voltage (A0 and A2 terminals)
Electrical lifetime
1.24
AC 1000 - 11/03
VAC
VDC
millions of operations
≤ 250
–
4 (600 ops.h) on A9 – A40
2 (600 ops./h) on A45 – A110
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
ro
co ss
nt the
ac
to line
rs
Accessories
for A/AE/AL/AF contactors
1
Terminal lug kits (Set of 3)
Wire
range
For
contactor
6 – 250 MCM
4 – 400 MCM
(2) 4-500 MCM
(2) 2/0 – 500 MCM
(3) 2/0 – 500 MCM
(4) 4/0 – 500 MCM
(4) 1/0 – 750 MCM
(6) 1/0 – 750 MCM
ATK185
Catalog
number
A145 – A185
A210 – A300
A210 – A300
AF400 – AF580
AF580 – AF750
AF1350
AF1350 – AF1650
AF1350 – AF1650
List
price
ATK185
ATK300
ATK300/2
ATK580/2
ATK750/3
ATK1350/4
ATK1650/4
ATK1650/6
Contact kits
$ 45
68
110
150
225
235
335
560
Catalog
number
For contactors
List
price
3 Pole
ATK750/3
ZL75
A/AE/AF50
A/AE/AF63
A/AE/AF75
A/AE/AF95
A/AE/AF110
ZL50
ZL63
ZL75
ZL95
ZL110
$ 113
135
158
225
255
A/AF145
A/AF185
A/AF210
A/AF260
A/AF300
ZL145
ZL185
ZL210
ZL260
ZL300
300
420
525
855
1020
AF400
AF460
AF580
AF750
AF1350
AF1650
ZL400
ZL460
ZL580
ZL750
ZL1350
ZL1650
1716
2434
3795
3960
4255
4890
A/AE45
A/AE50
A/AE75
ZLT45
ZLT50
ZLT75
150
150
210
UA50
UA75
UA95
UA110
ZLU50
ZLU75
ZLU95
ZLU110
150
215
306
347
4 Pole
3 Pole
Mechanical latches
Catalog
number
For contactors
ZL145
A9 - A75, AE45 - AE75, & AL9 - AL40
List
price
WB75A-★
$ 84
★ - Coil voltage suffix. Refer to Coil Voltage Selection chart and substitute the desired coil voltage suffix for the ★.
Coil voltage selection chart — mechanical latches for A, AE & AL contactors
50 Hz (DC)
24
42
48
110
WB75A-04
Voltage
code
60 Hz (AC)
24
42
48
110
–
–
–
–
28
48
55
127
01
02
03
04
50 Hz (DC)
220
230
380
415
–
–
–
–
230
240
415
440
Voltage
code
60 Hz (AC)
220
230
380
440
–
–
–
–
255
277
440
480
06
05
07
08
Range: WB75A for contactors A9 – A75, AL9 – AL40, AE45 – AE75 and control relays N and NL.
Description: WB75A block: contains a mechanical latching device with electromagnetic impulse unlatching (AC or DC)
or manual unlatching. Captive screw type connecting terminals, built-in cable clamps, M 3.5 (=, -) posidrive 1 screw with
screwdriver guidance, delivered untightened and protected against accidental direct contact.
Operation: After closing, the contactor continues to be held in the closed position by the latching mechanisim should the
supply voltage fail at the contact coil terminals.
Contactor opening can be controlled:
•
•
Electrically by an impulse* (AC or DC) on the WB75A block coil. The coil is not designed to permanently energized.
Manually by pressing the pushbutton on the front face of the WB75A block.
Mounting: WB75A is clipped onto the front face of the contactor.
Identification markers
Mounting
on
BA5-50
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Coil
voltage
A/AE/AL/AF9 – A/AE/AL/AF110
Discount schedule ABA
Pack of 50
Catalog
number
List
price
BA5-50
$ 15
1.25
AC 1000 - 11/03
1
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
1
Accessories
for A/AE/AL/AF contactors
Coils & coil voltage codes
Coils — AC operated
Catalog
number
For contactors
List
price
A9
A26
A45
A95
A145
A210
–
–
–
–
–
–
A16
A40
A75
A110
A185
A300
ZA16-★
ZA40-★
ZA75-★
ZA110-★
ZA185-★
ZA300-★
$ 24
30
57
60
150
180
AE9
AE26
AE45
AE95
–
–
–
–
AE16
AE40
AE75
AE110
ZAE16-★
ZAE40-★
ZAE75-★
ZAE110-★
24
30
57
90
CCL18-01
45
ZA16-81
Coils — DC operated
Auxiliary including an insertion contact and a varistor for DC operated contactors
AE95 – AE110
Coils — AC/DC operated
AF45 – AF75
AF95, AF110
AF145 – AF185
AF210 – AF300
AF400, AF460
AF580, AF750
AF1350, AF1650 (Set of 2))
ZAF1650
ZAF75-★
ZAF110-★
ZAF185-★
ZAF300-★
ZAF460-★
ZAF750-★
ZAF1650-★
120
165
200
240
450
525
920
Printed circuit board — AC/DC operated
AF1350 – AF1650
ZP1650
1620
★ – Coil voltage suffix. Refer to Coil Voltage Selection charts below and substitute the desired coil voltage code for the ★.
ZP1650
Coil voltage selection — DC operated for AE contactors
Coil voltage selection — AC operated
for A9 – A300; UA26 – UA110
1
2
3
4
5
VAC (50Hz)
VAC (60Hz)
24
26
28
42
48
60
100
110
110 – 115
120
125 – 127
175
190
200
220 – 230
230 – 240
230 – 240
230/400
—
380 – 400
400 – 415
—
440
500
550
660 – 690
24
28
32
42
48
60
100 – 110
110 – 120
115 – 127
140
150
208
220
200 – 220
230 – 240
240 – 260
277
—
230/400
400 – 415
415 – 440
480
500
600
—
—
VDC
Voltage code
AE
contactors
12
24
42
48
50
60
75
110
125
220
240
250
80
81
82
83
21
84
85
86
87
88
89
38
Voltage
Code
81
16
17
82
83
73
74 2
84
89 3
29
30
34
36
75 2
80
88
42
62 1
63 1
85
86
51
53
55
56
58
Coil voltage selection — AC/DC operated for AF50 – AF750
VAC & VDC
40-60 Hz
24 – 60 VDC
20 – 60 VDC
48 – 130 VAC/VDC
100 – 250 VAC/VDC
Suffix
Code
68 4
72 5
69
70
Only for A9 – A16.
Not for A145 – A300
A145 – A300 at 60 Hz, 115V only.
AF400 – AF750, DC only.
AF145 – AF300.
1.26
AC 1000 - 11/03
Discount schedule ABA
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
ro
co ss
nt the
ac
to line
rs
Accessories
for EK contactors
Coils & coil voltage codes
Coils — AC & DC operated
AC Coils
Contactor
size
Catalog
number
EK110, EK150
EK175, EK210
EK370, EK550
KH210-★
KH300-★
KH800-★
1
DC Coils
List
price
$ 100
120
290
Catalog
number
List
price
KH210-★
KH300-★
KH800-★
$ 130
160
350
★ – Coil voltage suffix. Refer to the Coil Voltage Selection chart and substitute the desired coil voltage suffix for the ★. AC and DC operated contactors DO NOT have the
same magnet structure. Therefore, DC coils will not fit on an AC magnet structure and vice versa.
Coil voltage selection — AC operated
for EK110 – EK550
Coil voltage selection — DC operated
for EK110 – EK550
VAC (50Hz)
VAC (60Hz)
Voltage
Code
–
24
–
110
–
–
220 – 230
–
380 – 400
400 – 415
–
500
–
24
–
48
120
208
240
–
380
440
–
480
–
600
F
N
G
1
B
2
J
Z
3
M
4
5
6
VDC
Voltage
Code
24
48
110
125
220
440
Y
W
P
Q
R
T
Consult factory if other voltages are required.
Consult factory if other voltages are required.
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule AB
1.27
AC 1000 - 11/03
1
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
1
Accessories
for A/AE/AL/AF contactors
Connection kits for reversing
Catalog
number
Mounting on 3 pole contactors
BEM...
A1
A2
1
3
5
1
3
5
2
4
6
2
4
6
BEM circuit diagram
A2
A/AE/AL9 – A/AE/AL16
A/AE/AL26
A/AE/AL30, A/AE/AL40
BEM16-30
BEM26-30
BEM40-30
$ 23
30
45
A/AE/AF50 – A/AE/AF75
A/AE/AF95, A/AE/AF110
A/AF145 – A/AF185
A/AF210 – A/AF300
BEM75-30
BEM110-30
BEM185-30
BEMA300-30
165
180
260
470
AF400 – AF460
AF580 – AF750
BEM460-30
BEM750-30
850
1200
Application
Connections between the main poles of two 3 pole contactors mounted side by side so that they operate as reversing
contactors.
Description
The connection kits for reversing contactors are made up of three reversing connections and three phase to phase
connections.
BEM16-30
— Insulated, solid, rigid copper wires
BEM26 and 40-30
— Insulated, stranded, rigid copper wires
BEM75 and 110-30
— Insulated, solid copper bars
BES...
A1
A2
A1
List
price
A1
1
3
5
1
3
5
2
4
6
2
4
6
Connection kits for phase to phase
A2
Catalog
number
Mounting on 3 pole contactors
A/AE/AF50,
A/AE/AF75
A/AE/AF95,
A/AE/AF110
A/AF145 – A/AF185
A/AF210 – A/AF300
BES110 connection diagram
AF400 – AF460
AF580 – AF750
List
price
BES75-30
BES110-30
BES185-30
BESA300-30
$ 75
90
130
200
BES460-30
BES750-30
425
650
Catalog
number
List
price
The connection kit for phase to phase contactors is made up of three phase to phase bus bars.
Connection kits for wye-delta starters
Mounting on contactors
BED...
Line and delta contactor
Wye contactor
A30
A40
A26
A26
BED40U
$ 53
A50
A63
A30
A40
BED50U
165
A75
A95
A110
A145
A185
A210
A50
A75
A95
A110
A145
A185
BED75U
BED95U
BED110U
BED145U
BED185U
BED210U
180
195
225
250
290
375
A260/A300
A210
BED300U
500
AF400/AF460
A260/A300
BED400U
850
AF460
AF400
BED460U
900
AF580
AF400/AF460
BED580U
1250
AF750
AF580
BED750U
1450
Application
Connections between the main poles of a wye-delta starter.
Description
The connection kits for wye-delta starters are made up of:
• Three line contactor/wye contactor connections — line side.
• Three wye contactor/delta contactor connections — load
side.
• The shorting connection for the “S” contactor.
BED40U – Insulated, stranded, rigid copper wires.
BED50U thru BED750U — Insulated, solid copper bars.
The above connection sets allow a mechanical interlock unit to be
mounted between the wye and delta contactors if required.
1.28
AC 1000 - 11/03
Discount schedule ABA
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
ro
co ss
nt the
ac
to line
rs
Accessories
for A/AE/AL/AF contactors
1
Additional terminal blocks
Wire
range
Mounting on 3 pole contactors
A/AE/AL9 – A/AE/AL16 (set of 2)
A/AE/AL26 (set of 2)
A/AE/AL30 – A/AE/AL40
A/AE/AF50 – A/AE/AF75
A/AE/AF95 – A/AE/AF110
16 – 6
14 – 6
12 – 4
10 – 2
8–1
Catalog
number
List
price
LD-16
LD-26
LD-40
LD-75
LD-110
$ 20
22
26
28
30
Utilization – The LD series terminal block is designed to increase the connection capacity of the contactor on which it is
mounted. The LD 75 and LD110 terminal blocks are mounted in the three independ apertures located above the built-in
connectors.
Terminal extensions
Mounting
on contactors
A/AE/AF50 – A/AE/AF75
A/AE/AF95, A/AE/AF110
A/AF145 – A/AF185
A/AF210 – A/AF300
AF400 – AF460
AF580 – AF750
LD110
Catalog
number
List
price
BEXT-75
LW-110
LX185
LX300
$ 15
15
90
140
LX460
LX750
195
225
Application
They are designed to increase the width of the contactor terminal pads to allow larger connectors to be mounted.
Description
Terminal extension sets contain 3 bars.
Terminal shrouds — two pieces
For contactor
BEXT-75
LX...
A/AF145
A/AF145
A/AF145
A/AF210
A/AF210
A/AF210
–
–
–
–
–
–
A/AF185 for flush mount
A/AF185 for extended mount
A/AF185 for shorting bar LY...between A(F)145 / A(F)185 & TA200DU
A/AF300 for flush mount
A/AF300 for extended mount
A/AF300 for shorting bar LY300
LT185-AC
LT185-AL
LT185-AY
LT300-AC
LT300-AL
LT300-AY
AF400
AF400
AF580
AF580
–
–
–
–
AF460 for flush mount
AF460 for extended mount
AF750 for flush mount
AF750 for extended mount
LT460-AC
LT460-AL
LT750-AC
LT750-AL
List
price
$ 10
20
Terminal enlargements
For contactor
A/AF95
A/AF145
A/AF210
AF400
AF580
LT185-AC
Catalog
number
–
–
–
–
–
A/AF110
A/AF185
A/AF300
AF460
AF750
Catalog
number
LW110
LW185
LW300
LW460
LW750
List
price
$ 95
120
130
295
355
Arc chutes
For contactor
A/AF145
A/AF210
A/AF400
A/AF580
–
–
–
–
A/AF185
A/AF300
A/AF460
A/AF750
Catalog
number
ZW185
ZW300
ZW460
ZW750
List
price
$ 130
180
190
230
LT185-AL
LW...
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule ABA
1.29
AC 1000 - 11/03
1
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
1
Accessories
for A/AE/AF contactors
Vertical connection bars between contactor and MCCB — three bars
MCCB
BEA185/S3/S4
Catalog
number
For contactor
T3
S3, S4
S4
S5
S51
S6
A/AF145
A/AF145
A/AF210
A/AF210
AF400
AF400
–
–
–
–
–
–
A/AF185
A/AF185
A/AF300
A/AF300
AF460
AF750
BEA185/T3
BEA185/S3/S4
BEA210/S4
BEA300/S5
BEA400/S5
BEA750/S6
List
price
$ 60
60
70
75
95
115
Vertical connection bars between contactor and MCCB — three bars
MCCB
S3, S4
S4
S5
S5
S6
BEAD185D/S3/S4
Catalog
number
List
price
BEA185D/S3/S4
BEA210D/S4
BEA300D/S5
BEA400D/S5
BEA750D/S6
$ 70
80
85
105
125
For contactor
A/AF145
A/AF210
A/AF210
AF400
AF400
–
–
–
–
–
A/AF185
A/AF300
A/AF300
AF460
AF750
To be used when power take off is needed (IP00) or with other bus bars. (EX: Reversing, IP20)
Horizontal connection busbars between contactor and MCCB — three bars
MCCB
BEA185H/S4
Catalog
number
For contactor
List
price
S3, S4
S4
S5
A/AF145 – A/AF185
A/AF210 – A/AF300
A/AF210 – A/AF300
BEA185H/S4
BEA210H/S4
BEA300H/S5
$ 150
220
220
S5
S6
S6
AF400 – AF460
AF400 – AF460
AF580 – AF750
BEA400H/S5
BEA460H/S6
BEA750H/S6
435
660
670
Shorting bars, 2 pole
Catalog
number
For contactor
List
price
A/AF145 – A/AF185
A/AF210 – A/AF300
LP185
LP300
$ 35
50
AF400 – AF460
AF580 – AF750
LP460
LP750
50
50
LP185
Shorting bars, 3 pole
Catalog
number
For contactor
A/AE45 – A/AE/AF75
LF75
List
price
$ 40
A/AE/AF95 – A/AE/AF110
A/AE/AF145 – A/AE/AF185
A/AE/AF210 – A/AE/AF300
LY110
LY185
LYA300
40
40
60
AF400 – AF460
AF580 – AF750
LY460
LY750
60
60
LY...
Vertical connection bars between contactor and disconnect switch
Disconnect
switch
For
contactor
Catalog
number
List
price
OS160
OESA250
OESA250 - OESA400
A/AF145
A/AF185
A/AF210 - A/AF300
OSZA15
BEF185V/OESA250
BEF300V/OESA400
$ 200
260
270
OESA400
OESA630 - OESA800
AF400 - AF460
AF460 - AF750
BEF460V/OESA400
BEF750V/OESA800
300
320
Horizontal connection bars between contactor and disconnect switch
Disconnect
switch
For
contactor
Catalog
number
List
price
OESA250
OESA250 - OESA400
A/AF145 - A/AF185
A/AF210 - A/AF300
BEF185H/OESA250
BEF300H/OESA400
$ 515
595
OESA400
AF400 - AF460
BEF460H/OESA400
615
1 Not for use with flange handles.
1.30
AC 1000 - 11/03
Discount schedule ABA
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
ro
co ss
nt the
ac
to line
rs
Accessories
for A contactors
TE5S electronic timer for wye-delta starters
1
Electronic timer
For
contactors
Rated control
voltage Uc
V
Packing
piece
Unit
weight
kg
Catalog
number
List
price
A9 – AF750
24 AC/DC
110 – 115 AC
220 – 230 AC
1
1
1
0.080
0.080
0.080
TE5S-24
TE5S-115
TE5S-230
$ 120
Application
Utilization
When used in wye-delta starters, the TE5S lags the wye connection and provides a lapse of 50 ms before the switchover to
the delta connection.
Description
TE5S-*
According to the type of device chosen, the electronic circuit has a 24 VAC/VDC, 110 – 120 VAC or 220 – 230 VAC supply.
An output relay with reversing contact ensures high current switching. A two-position switch allows selection of one of the
two time delay ranges: 0.8 to 8 s or 6 to 60 s. The 0.1 to 1.0 adjustable knob allows an initial setting without steps within the
previously selected range which can then be adjusted using a stopwatch.
U
Note: We recommend that you allow for temperature drift for the final adjustment of the time delay setting.
Drift:
– 0.2% per °C. For example, a setting made at 20 °C will yield a time delay shorter by 7% at 55 °C in an enclosure. ( – 0.2%
per °C i.e. – 0.2 x 35 = – 7%).
15-16
R
15-18
t1
t2 = 50ms
Operation
15
A1
Chart
t1
18
16
On energization, the green U indicator light (voltage applied) comes on. Contact 15 – 16 then immediately moves to the
closed position.
Count-down of the programmed time immediately commences.
t1+t2
A2
TE 5S
The TE5S, which is not affected by these settings, establishes a fixed “lapse” of 50 ms between the opening of contact 15
– 16 and the closing of contact 15 – 18. It is this time delay that prevents from arc short-circuit during wye to delta switching.
Equivalent diagram
When the time delay has elapsed, contact 15 – 16 opens and at the same time the 50 ms lapse, t2, begins after which contact
15 – 18 moves to the closed position. The yellow R indicator light comes on.
On de-energization, the U and R indicator lights go out and, after the 250 ms resetting time, the device is ready for a new
cycle.
Mounting
Mounts on 35mm DIN rail.
A1
15
TE5S
U
0.5
0.1
1.0
0.8 ... 8s
t1
6 ... 60s
R
Star-Delta Timer
16
18
A2
Front face
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Discount schedule ABA
1.31
AC 1000 - 11/03
1
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
1
Accessories
for A contactors
TE5S electronic timer for wye-delta starters
Technical data
Type
TE5S-24
Compliance with standards
TE5S-115
Rated insulation voltage Ui according to IEC 947-5-1
V
Rated supply voltage Uc
VDC
VAC
Rated frequency limits
250
24
24
Hz
—
110 – 115
0.85 – 1.1 Uc
Overvoltage protection
Built-in varistor
Load factor
%
Average consumption
in DC
in AC
W
VA
Time delay range (t1 ) selected by switch
S
Temperature drift
% per °C
100
0.7
1.5
—
3.5
- 0.2
± 15% of the setting range
On-load reiteration accuracy
under constant conditions
± 2% after 1 million operations
Minimum time lapse (t2 )
Min. time lapse after 1 million operations
Resetting time (maximum)
ms
50
ms
40
ms
250
green indicator light
yellow indicator light
Energization
Output relay activated
Rated operational voltage Ue acc. to IEC 947-5-1
VDC
VAC
24
24 – 230
Conventional free air thermal current Ith
A
10
Rated operational current Ie acc. to IEC 947-5-1
DC-13
24 VDC
A
4
A
A
5
4
°C
°C
-25 … +60
-40 … +85
24 – 115 VAC
220 – 230 VAC
Permissible air temperature
for operation
for storage
Mechanical durability in millions of operations
5
Electrical durability in millions of operations
1
On-load maximum switching frequency
ops./h
Shock and vibration withstand
35 x 7.5 or 35 x 15
Connecting terminals
(+,-) pozidriv 1 screw
Tightening torque
Flexible without cable end
720
on request
Fixing on mounting rail according to EN 50022
Connecting capacity
Rigid solid
—
6.5
0.8 – 8 and 6 – 60
Mechanical setting accuracy
Front panel display:
—
220 – 230
48 – 63
Supply voltage range
AC-15
TE5S-230
IEC 947-5-1, EN 60947-5-1 and VDE 0435
N.m
0.6 – 0.8 max.
1 or 2 x mm2
1 – 2.5
1 or 2 x mm2
0.75 – 2.5
Degree of protection acc. to IEC 529, IEC 947-1 and EN 60 529
1.32
AC 1000 - 11/03
Housing
IP 50
Terminals
IP 20
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
ro
co ss
nt the
ac
to line
rs
Accessories
Terminal markings
CA/CC/CAL/CCL auxiliary contacts
1
One pole auxiliary contacts
-3
-1
-3
-1
NO
NC
NO
NC
-4
-2
-2
-4
CA5-01
CA5-10
CE5-10
CE5-01
-7
-5
NO
NC
-8
-6
CC5-10
CC5-01
Two pole auxiliary contacts
83X
13X
21X
31X
72X /
84X /
CAL5-11B (R. h. s. mounted)
18X
26X
25X
48X /
17X
43X
36X
48X
35X
47X
14
NO
NO
NC
36X /
71X
44X
13
47X /
62X /
83X /
NC
61X
35X /
CCL5-11 (L. h. s. mounted)
NO
54X /
71X /
NC
CAL5-11B (L. h. s. mounted)
CAL5-11 (R. h. s. mounted)
NC
26X /
44X /
61X /
NO
NO
53X
32X
25X /
NO
18X /
22X
17X /
14X
32X /
CAL5-11 (L. h. s. mounted)
53X /
84X
22X /
43X /
NC
72X
14X /
31X /
NC
62X
21X /
NO
54X
13X /
CCL5-11 (R. h. s. mounted)
21
31
NC
NC
22
32
CAL16-11 A
53
61
71
83
35
47
NO
NC
NC
NO
NC
NO
54
62
72
84
36
48
43
NO
44
CAL16-11 B
CAL16-11 C
CAL16-11 D
CCL16-11 E
Four pole auxiliary contacts
11
21
31
41
21
31
41
51
51
61
71
81
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
12
22
32
42
22
32
42
52
52
62
72
82
CA5-04 E
13
NO
14
21
31
NC
NC
22
32
43
NO
44
13
14
21
NC
33
NO
22
34
43
NO
44
13
14
23
NO
24
31
NC
NC
22
32
43
NO
53
NO
54
44
21
NC
22
33
NO
43
NO
34
33
NO
34
53
NO
44
54
13
14
54
51
NC
52
53
43
—
NO
61
71
NC
NC
62
72
83
NO
84
63
NO
73
NO
64
83
NO
74
84
CA5-31 N
NO
54
44
63
NO
73
NO
64
74
83
NO
84
CA5-40 N
CA5-40 E
NO
53
NO
CA5-22 N
CA5-31 M
CA5-31 E
NO
21
CA5-22 M
CA5-22 E
NO
CA5-04 N
CA5-04 M
21
35
NC
NC
22
36
CA5-11/11 E
47
NO
48
21
NC
22
33
NO
34
45
NC
57
NO
46
58
CA5-11/11 M
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
1.33
AC 1000 - 11/03
1
1
e
lin
e
th rs
ss acto
o
r
t
Ac con
1
Accessories
Terminal markings & positioning
for A/UA contactors
Standard devices without addition of auxiliary contacts
A2
A1
A2
A1
A1
1L1 3L2 5L3 21
1L1 3L2 5L3 13
NC
NO
NC
NO
2T1 4T2 6T3 22
2T1 4T2 6T3 14
A2
R3
R4
2
3L2
4T2
2T1
8
R6
5L3
1L1
3L2
5L3
A2
2T1
4T2
6T3
21
NC
4T2 6T3
NC
22
A9 – A40-30-01
A50 – A110-30-00
UA50 – UA110-30-00
A1
1L1
3L2
5L3
A2
2T1
4T2
6T3
13
NO
NO
14
A9 – A40-30-10
A1
1L1 3L2
5L3
A2
2T1 4T2
6T3
A50 – A110-30-00
UA50 – UA110-30-00
7L4
5L3
A1
1
R3
R5
7
A2
2
R4
R6
8
A1
1L1
3L2
5L3
7L4
A2
2T1
4T2
6T3
8T4
8T4
6T3
A2
A2
A9 – A26-40-00
A45 – A75-40-00
A9 – A26-22-00
A45 – A75-22-00
A9 ... A26-40-00
A45 ... A75-40-00
A9 – A26-22-00
A45 – A75-22-00
A1
A2
A1
1L1
7
R5
A2
A2
A9 – A40-30-10
A2
A1
2T1
A2
A9 – A40-30-01
1
3L2
1L1
Standard 3 pole devices with factory mounted auxiliary contacts
A2
A1
A1
1L1 3L2 5L3
13
21
NO NC
14
22
31
3L2
1L1
43
13X
43X
21X
31X
22X
32X
32
44
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
6T3
A2
2T1
4T2 6T3
NO
14
NC
22
NC
32
NO
44
A2
A9 – A16-30-22
A50 – A110-30-22
44X
14X
4T2
2T1
A2
A9 – A16-30-22
Combination
22
2
A1
A2
A1
1L1 3L2 5L3 13
31
A1
NC NO
2T1 4T2 6T3
21
A2
5L3
43
3L2
1L1
NO
53
A2
5L3
NO 13X
NC 21X
NC NC
NO NO
A1
NC 22X
22
32
44
54
NO
1L1
3L2
5L3
13
NO
21
NC
31
NC
43
NO
53
NO
NO
14
NC
22
NC
32
NO
44
NO
54
4T2
2T1
2T1 4T2 6T3 14
6T3
A2
A2
A2
2T1
4T2 6T3
A9 – A40-30-32
A50 ... A110-30-11
UA50 ... UA110-30-11
A9 – A40-30-32
A2
A1
A1
1L1 3L2
A2
1L1 3L2 5L3 13
1L1 3L2 5L3 13
NO
NO
A2
=
+
2-
NO
NO
2T1 4T2 6T3 14
2T1 4T2 6T3 14
A2
5L3 13
2-
21
=
2-
6-
14
22
A1
5L3
43
1L1
3L2
NO
NO
2T1 4T2 6T3 14
A2
44
43X NO
NC 21X
4T2 6T3
A2
A50 – A110-30-22 =
1.34
AC 1000 - 11/03
6T3
31X NC
+
NC 22X
32X NC
NO 14X
44X NO
2T1
4T2
NO
14X
NC
22X
A1
1L1
3L2
5L3
13
NO
21
NC
A2
2T1
4T2
6T3
NO
14
NC
22
A9 – A40-30-10 + CA5-01 + CA5-10
A2
3L2
1L1
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NO
34
Combination 21
A1
1L1
3L2
A2
2T1
NO NC NC
4T2 6T3 14X 22X 32X
5L3
A2
A1
7L4
5L3
A1
3L2
13X 21X 31X 43X
NO NC NC NO
7L4
5L3
A2
=
5-
=
6- 13 2- 3- 4- 5NO
6- 14 2- 3- 4- 5-
2T1
4T2
6T3
6- 1- 2- 3- 4- 5-
+
=
6- 1- 2- 3- 4- 5-
8T4
2T1
A2
2T1
-3
NO
-4
+
5L3
5-
NC NO
32
3-
2T1 4T2 6T3 14
Combination
21
A9 – A40-30-10 + CA5-01
A2
31
-1
NC
-2
+
A2
NO 13X
13
3-
=
A1
NO NC
NO
21 33
NC NO
22 34
-1
NC
-2
1L1
6-
2T1 4T2
5L3 13
A2
Combination
11
3L2
A2
13X 21X
NO NC
Combination 11
2-
21
NC
22
A1
5L3
A2
A1
1L1 3L2
NO
1L1
1L1 3L2
A50 – A110-30-11
UA50 – UA110-30-11
Other possible contact combinations with auxiliary contacts added by the user
A1
A1
NO 14X
4T2
6T3
-3
NO
-4
Combination 22
A1
1L1
3L2
5L3
7L4
13
NO
A2
2T1
4T2
6T3
8T4
NO
14
8T4
A2
6T3
A2
A50 – A75-30-11
+ CAL5-11
Combination
10
NO
44X
=
A45 – A75-40-00
+ CA5-10
Combination 10
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
Ac
ro
co ss
nt the
ac
to line
rs
Accessories
Terminal marking and positioning
for AE/AL contactors
AE Contactors — D.C. operated
3L2
3L2
1L1
5L3
A2
A1
A2
A1
A2
A1
1L1
3L2
1L1
5L3
VDC
5L3
NC 21X
NC 22X
1L1 3L2
A1
AE50 – AE75-30-00
3L2
1L1
A2
A1
R3
1
5L3
1L1
3L2
NC 22X
NC
22X
4 T2
5 L3
6 T3
Coil wiring
A1
1
R3
R5
7
A2
2
R4
R6
8
VDC
{
A1
A2
A3
U
7L4
5L3
C
D
L
5
C
C
L
5
36 X
2 T1
3 L2
AE50 – AE110-30-11
NO 13X
NC 21X
NO
14X
6T3
1 L1
A2
A1
7
R5
2T1 4T2
A2
AE95 – AE110-30-00
AE50 – AE75-30-11
A2
A1
A3
A3
A3
A3
U
13X 21X
NO NC
5L3
4T2 6T3
2T1
6T3
4T2
2T1
4T2 6T3
A1
A2
35 X
NO 14X
2T1
{
AE50 – AE110-30-00
C
C
L
5
C
D
L
5
6T3
2T1 4T2
A2
NO 13X
C
D
L
5
5L3
1L1 3L2
A1
1
15 X
16 X
AE45 – AE75-22-00
C
D
L
5
A1
1L1
3L2
5L3
7L4
A2
2T1
4T2
6T3
8T4
1 L1
2 T1
7 L4
8 T4
NO 14X
4T2
2T1
6T3
R4
2
8
R6
A3
2T1
4T2
AE95 – AE110-30-11
8T4
6T3
A3
A3
AE45 – AE75-22-00
AE45 – AE75-40-00
Coil wiring
AE45 – AE75-40-00
AL Contactors — D.C. operated
Standard devices without addition of auxiliary contacts
A1
A1
1L1 3L2 5L3 21
1L1 3L2 5L3 13
NC
NO
NC
NO
2T1 4T2 6T3 22
2T1 4T2 6T3 14
A1
A2
A2
AL9 – AL40-30-01
A1
1
R3
A2
AL9 – AL40-30-10
R4
3L2
5L3
2T1
4T2
6T3
A1
21
NC
NC
22
A2
1L1
3L2
5L3
2T1
4T2
6T3
13
NO
NO
14
AL9 – AL40-30-10
AL9 – AL40-30-01
A1
R5
7
1L1 3L2 5L3 7L4
A1
2
1L1
R6
8
1
R3
R5
7
A1
2
R4
R6
8
A2
1L1
3L2
5L3
7L4
2T1
4T2
6T3
8T4
2T1 4T2 6T3 8T4
A2
A2
AL9 – AL26-22-00
A2
AL9 – AL26-40-00
AL9 – AL26-40-00
AL9 – AL26-22-00
Other possible contact combinations with auxiliary contacts added by the user
A1
A1
1L1 3L2 5L3 13
1L1 3L2 5L3 13
NO
21 33
NC NO
22 34
NO
2-
3-
4-
5-
2-
3-
4-
5-
=
+
NO
NO
2T1 4T2 6T3 14
2T1 4T2 6T3 14
A2
Combination
21
-1
NC
-2
+
-3
NO
-4
A2
=
AL9 – AL40-30-10
Low Voltage Products & Systems
ABB Inc. • 888-385-1221 • www.abb-control.com
+ CA5-01
+
CA5-10
A1
1L1
3L2
5L3
13
NO
21
NC
33
NO
A2
2T1
4T2
6T3
NO
14
NC
22
NO
34
Combination 21
1.35
AC 1000 - 11/03
1