Huawei UPS5000-E Series Modular UPS, 25 – 800kW Features snapshot Modular UPS Smooth capacity expansion Online maintenance, reducing MTTR High efficiency up to 99% (in ECO mode) Intelligent hibernation design Small footprint Smart battery management Designed for the modern data centre, the modular Huawei UPS5000-E Series is scalable for capacity expansion and redundancy, therefore reducing initial investment. The integrated modular control also ensures that the series is able to offer superior efficiency levels. Its intelligent and flexible battery management, online maintenance and hot swappable modules make it not only one of the most user friendly systems but also one of the most technologically advanced, efficient and modular solutions available. THE POWER AUTHORITY Power Control Ltd, Rotherside Road, Eckington, Sheffield, S21 4HL t: +44(0)800 136 993 f: +44(0)1246 431444 e: info@pcl-ups.com www.pcl-ups.com UPS 50000-E Series MODELS UPS5000-E-125K-F125 UPS5000-E-120K-F120 UPS5000-E-200K-F200 UPS5000-E-320K-F320 UPS5000-E-480K-F480 UPS5000-E-600K-F600 UPS5000-E-800K-F800 Capacity up to 125KW up to 120kW up to 200kW up to 320kW up to 480kW up to 600kW up to 800kW Capacity per module 25kW No. of modules 1-5 40kW 1-3 Dimensions W x D x H (mm) Frame weight (KG) 1-5 195 1 - 12 1-15 1 - 20 1200 x 850 x 2000 2000 x 850 x 2000 2400 x 850 x 2000 661 1013 1153 221 Module weight (KG) Input/output connection 1-8 600 x 850 x 2000 32.5 Hardwired; top or bottom entry Battery Hardwired; bottom entry (additional cabinet available for top entry) External, 180 - 240 cells INPUT Input wiring 3Ph+N+PE Nominal voltage 380/400/415 VAC Voltage range 138 - 485 VAC Input frequency 40-70Hz Power factor 0.99 Current distortion (THDi) < 3% for linear load; < 5% for non linear load OUTPUT Output wiring 3Ph+N+PE Nominal voltage 380/400/415VAC ± 1% Frequency Tracks the bypass input (Online mode); 50/60Hz ± 0.1% (Battery mode) Power factor Unity Overload capacity 110% for 60 minutes; 125% for 10 minutes; 150% for 60 seconds Efficiency 96% VFI Mode; 99% Eco Mode USER INTERFACE Front panel 7-inch Colour LCD Touch Screen Communication Optional Dry contacts; RS485; SNMP Extended dry contact card; Backfeed protection card; Battery monitoring; Battery ground fault detector ENVIRONMENTAL Operating temperature 0°C - +40°C (SLA batteries 20-25°C) Storage temperature -40°C - +70°C Altitude Noise (dB) 1000-4000m; >1000m load capability decreases by 1% per 100m <65 <68 Full technical specification and product information can be found at www.pcl-ups.com <70