DIN-RAIL KWH Meter

advertisement
ADM
DIN-RAIL KWH Meter
1. Applications
ADM is a kind of electronic Din rail watt-hour meter.It completely accords with relevant technical requirements of class 1 and class 2. It can accurately and directly measure active energy
consumption. It also can display total energy consumption by step type impulse register or LCD
display. This watt-hour meter is according to EN62053-21.
ADM25SC
Conform to EN62053-21 Accuracy
Frequency
Single phase
Rated impulse voltage
Power consumption
Temperature range
class 1,2
50/60Hz
120V/230V
Uimp 6KV-1.2/50S
1.5w/6VA per phase
-10-+50
Conform to EN62053-21 Accuracy
Frequency
Three phase
Rated impulse voltage
Power consumption
Temperature range
class 1,2
50/60Hz
230V/400V
Uimp 10KV-1.2/50S
2w/10VA per phase
-10-+50
2. Specification
ADM65S
TYPE
ADM25S
ADM25SC(LCD)
ADM65S
ADM100S
ADM100S
ADM100SC
(LCD)
ADM100SC
ADM100T
ADM100TC
(LCD)
ADM100TC
D-01
Rating
2.5(10)A
3(15)A
5(25)A
5(30)A
2.5(10)A
3(15)A
5(30)A
10(40)A
15(60)A
2.5(10)A
5(30)A
10(50)A
15(60)A
20(100)A
5(30)A
10(60)A
15(90)A
20(100)A
1.5(6)A CT
3(6)A CT
5(30)A
10(60)A
15(90)A
20(100)A
1.5(6)A CT
3(6)A CT
5(30)A
10(60)A
15(90)A
20(100)A
Voltage
Mounting:DIN rail EN 50022
Class
Designation
Single Phase 1
AC120V/230V
1.0/2.0
module
AC120V/230V
1.0/2.0
Single Phase 2
module
AC230V
AC120V/230V
1.0/2.0
Single Phase 4
module
230V
230V
1.0
230/400V
1.0
Single Phase 4
module
Three Phaes 7
230/400V
1.0
230/400V
1.0
module
Three Phase 7
module
DD862
DD28 DD862 DT862 DT8 Kilo Watt-hour Meter
1. Applications
The series single phase meter is a kind of induction meter to measure the single phase
current at the rated frequency of 50Hz. It is an indoor installed meter. Ambient temperature: 10°C to 50°C, relative humidity: below 85% (25°C). DT8 and DT862 series three-phase meter is
an induction meter to measure the three-phase current at the rated frequency (50Hz). It is an
indoor installed meter; Ambient temperature: -10°C to 50°C, except the first grade is under the
working condition of 0 to 40°C. Relative humidity: below 85% (25°C).
DD282
2. Specification
Item
Type
Accuracy
R.V.
Calibration (A)
Manner
2.5(10)5(20)10(40)
direct connction
DD862-4
15(60)20(80) 30(100)
single-
1.5(6)
DD862-2
phase
connection with
2
220
current transformer
3(6)
watt-meter
2(4)2.5(5)3(6)5(10)
DD282
DD28
10(20)20(40)30(60)
direct connection
40(80)5(20)10(40)
DD28
5(20)10(40)15(60)
three
phase
direct connection
DT862-4
20(80)3(100)
four-wire DT862-2
watt meter
2
3x380/220
1.5(6)
connection with
3(6)
current transformer
10.25.40.80
direct connection
DT8
DD862
DD862
DT862
DT862
D-02
DDS480
DDS480 Single Phase Electronic Kilowatt Hour
Meter
1. Application
DDS480 series electronic single phase watt hour meter is a high technology product adople
avanced IC technology as well as SMT technology, both circuit design and componects selectior
are up to various working environment to guaranty that power meter can operate steadily for a
lor time. the finished meter don’t neet to be adjusted so that the calibration cycle is long. it
extremely reduce the labor force of the electricity board for calibrating power meters. the feature
of the products are anti-thief, long life, high accuracy, high reliability, low power consumption
small volume, light weight, the meter is up to the according to IEC 1036-96 and GB/T17215-200
standard.
2. Spcification
Name
Type
Single Phase Electronic
Kilowatt Hour Meter
Accuracy(class)
Basic current
1.5(6)A,2.5(10)A,5(20)A,10(40)A,
DDS480
1.0, 2.0
45(60)A,20(80)A,5(30)A,10(60)A,
80ms 20ms
DTS480 Three Phase Electronic Kilowatt Hour
Meter
1. Application
DTS480 series electronic three phase watt hour meter is a high technology product adopted
advanced IC technology as well as SMT technology, both circuit design and components selectior
are up to various working environment to guaranty that power meter can operate stecdily for a
lon time, the finished meter don’t need to be adjusted so that the calibration cycle is long, it
extremely reduce the labor force of the electricity board for calibrationg power meters, the feature of the products are anti-thief, long life, high accuracy, high reliability, low power consumption small volume, light weight, the meter is up to the according to IEC 1036-96 and GB/T17215200 standard.
2. Name and specification
Name
Type
Accuracy
Rated voltage
Rated current
(class)
(V)
(A)
3x1.5(6), 3x3(6)
Three phase four
wire adive energy
electronic type watthotu meter
D-03
DTS480
1
3x380/220
Connection
CT
3x5(20), 3x10(40)
3x1.5(60), 3x5(30)
3x10(60)
Direct
SFC
Modular Type Panel Meter
MODEL
SPECIFICATION
NAME
AC AMMETER
DC AMMETER
AC VOLTMETER
SFC-45
SFC-100
DC VOLTMETER
ACCURACY
FROM 10A,15A, 20A,30ATO 3000A,500A
WITH EXT.C/T 1A OR 5A
CLASS 1.5
FROM 0.1A,0.5A, 1A,5A,10A,25ATO 80A,100A
AC DIRECT CONNECTION
CLASS 1.5
FROM 50µA,100µA, 1mA,5mA1A,5A,10A,25A,30ATO 100
DC DIRECT CONNECTION
CLASS 1.5
FROM 10A,15A, 20A,30A2500A,3000ATO 8KA,10KA
WITH EXT,SHUNT 50MV,60MV OR 75MV CLASS 1.5
FROM 30V,50V, 100VTO 300V,500V,600V
AC DIRECT CONNECTION
CLASS 1.5
FROM 1KV,2KV, 5KVTO 380KV,450KV
WITH EXT.VOLTAGE TRANSFORMER
CLASS 1.5
FROM 10V,20V, 30VTO 500V,600V,1000V
DC DIRECT CONNECTION
CLASS 1.5
FROM 1KV,2KV, 5KVTO 8KV,9KV,10KV
WITH EXT. RESISTOR
CLASS 1.5
CLASS 1.0
FOR IPHASE OR 3PHASE
CLASS 2.5
VOLTAGE: 110V,220V,380V,440V
FREQUENCY METER
FREQUENCY: 45-55Hz,45-65hZ,55-65Hz,47-53Hz
VOLTAGE: 10V,220V,380V,440V CURRENT: 1A OR 5A
POWER FACTOR METER(COS )
SCALE: 0.5cap-1-0.5ind, 0.3cap-1-0.1ind, 0.7cap-1-0.2ind
POWER METER(KW OR KVAR)
VOLTAGE: 110V,220V,380V,440V CURRENT: 1A OR5A
FOR IPIW,3P3W,3P4W
WITH C/T OR VOLTAGE TRANSFORMER
CLASS 1.5
1. Outline Drawing
2. Size Of Din Rail Type Series Meter
Model
Unit
D
Number of terminal
Measurement of din rail
SFC-45
mm
4
45
35
SFC-100
mm
10
100
35
D-04
AM72
Panel Meter
AC Ammeter
Model:AM-96 AM-72 AM-48
Class:1.5
Specs:0.1A 0.5A 1A 1.5A 3A 5A 7.5A 10A 15A 20A 25A 30A 50A 75-105A(use Ext.CT 5A)
Note:for60/75/100A direct meter,the class is 2.5.
Advantage:The scale can be easily changed without opening the front frame so that the class
will not be influenced.
DC Ammeter
Model:AM-96 AM-72 AM-48
Class:1.5
Specs:25uA 50uA 1mA 2mA 5mA 10mA 20mA 30mA 50mA 75mA 100mA 150mA 200mA 250mA
300mA 500mA 1A 3A 5A 7.5A 10A 20A 30A 50A 75-105A(used with Shunt)
Feature:The scale can be easily changed without opening the front frame so that the class will
not be influenced.
AC Voltmeter
Model:AM-96 AM-72 AM-48
Class:1.5
Specs:30V 50V 75V 100V 120V 150V 250V 300V 450V 600V For 450-380KV,should be used
with potential transformer secondary voltage 100V.
DC Voltmeter
Model:AM-96 AM-72 AM-48
Class:1.5
Specs:3V 5V 7.5V 10V 15V 20V 50V 75V 100V 120V 150V 200V 250V 300V 400V 450V 600V
Note:Over 600V should be used with Ext.Resistor.(Rated Cuuent 5mA).
MOVING COIL INSTRUMENTS FOR NONELECTRIC VALUES
Model:AM-96 AM-72
These meters can measure the other non-electric values for example,temperature,speed and
so on.
Frequency Meter
Pointer Type
Model:AM-96 AM-72 AM-48
Class:1.0
Volt:50V 100V 220V 380V
Freq:44-55Hz 45-66Hz 55-65Hz 47-53Hz 57-63Hz 44-56Hz 54-66Hz 450-550Hz 550-650Hz
D-05
AM96
Panel Meter
POWER FACTOR
For 3 phases circuits,balanced load 45-65Hz and for 1 phase AC 50Hz.
Model:AM-96 AM-72
Class:2.5
Voltage:100V 380V 440V
Frequency:50Hz 60Hz
Scale graduation:0.5cap-1-0.5ind 0.3cap-1-0.7ind 0.4cap-1-0.4ind 0.7cap-1-0.3ind.
Orders to be Noted:
Type of Current:1P,3P 3W circuits,balanced load.
Rated Volt:The voltage is line voltage(between two wires).
Operating Current:If used with CT,the secondary current 5A or 1A is standard.
POWER METER
Wattmeters with built-in converter for 1 phase,3P 3W,3P 4W.
Model:AM-96 AM-72
Class:1.5
Voltage:50V 100V 220V 240V 220/380V 240/415V
Current:5a
These meters are used with potential secondary voltage 100V voltage transformer or secondary
current 5A CT.wattmeters with built-in converter for 3P 3W,3P 4W and single phase.
MODEL:AM-96 AM-80 AM-72 AM-60 AM-50
Struction:Moving Coil,Moving Iron and Rectifier.
Class:2.0 2.5
Name
Remarks
Specifications
DC Ammeter
30-1000uA
1-1000mA
1K-10KA
1-50A
DC Voltmeter
40-1000mV
1-1000V
1K-10KA
1-50A
Direct connection
With EXt.Shunt
Direct connection
With EXt.Resistor
1-1000mA
1-50A
DC Ammeter
5-1000A
1K-0KA
Direct connection
With EXt.CT
40-1000mA
1-1000V
Direct connection
DC Voltmeter
1K-380KV
With EXt.CT
Voltage:50-380V
Frequency Meter
Power Factor Meter
Power Meter
Frequency:45-55Hz 45-65Hz 55-65Hz
Voltage:50-380V
Frequency:0.5cap-1-0.5ind
0.3cap-1-0.7ind
0.4cap-1-0.4ind
0.7cap-1-0.3ind
Suitable for 1Por 3P3W Circuit
Only AM-80 is available
Voltage:50-380V Current:0.2-5A
With Current or Voltage
Transformer
D-06
AM72
Digital Panel Meter
1. Application
Digital panel meter which is various and artistic in appearance design is used for dual slope, high precise A/D changeover circuit
and high light LED cassette setting specification. It is very convenient for user to fix the equipment.
2. Specification
Description
range
Input
current
range
Operation voltage
–
AC 220V 50/60Hz
0-1999
0.5
–
AC 220V 50/60Hz
0-1999
0.5
–
AC 220V 50/60Hz
0-1999
0.5
0-1999
–
0-1999
–
0.5-0-0.5
–
Frequency digital meter
AC
DC0-100V
AC 10-20A
DC 0-10A
AC 10-2KHZ
(20-300V)
AC tri-phase watt meter
AC 0-100V
AC 5A
AC single-phase watt meter
AC 0-220V
AC 10-5A
AC 380V 50/60Hz
AC 110V 50/60Hz
AC 220V 50/60Hz
AC 110V 50/60Hz
AC single-phase factor meter
AC 100-300V
AC 5A
AC 220V 50/60Hz
AC & DC digital
voltage meter
AC & DC digital
Ampere meter
AM72-H, AM96-H
AM72-Hz, AM96-Hz
AM72-V3, AM96-V3
AM72-A, AM96-A
AM48-HZ
AM-150V
D-07
Direct input
AM72-V, AM96-V
AM72-W, AM96-W
Display range Class
AM72-I3, AM96-I3
AM48-I
AM48-H
AM48-V
AM-150A
AM-150Hz