PerfectSense Intelligent Building Occupancy Sensors PRODUCT SELECTION GUIDE ® BENEFITS OF PERFECTSENSE Whether the goal is cost and time-saving installation, building energy efficiency, certification to national energy code regulation, retrofitting, flexibility, or building automation, NexLight’s PerfectSense Intelligent Building Occupancy Sensors meets any application need. EASY TO DESIGN Either installed to work independently, or connected to work with a building network lighting control system, PerfectSense products offer many ways to control area lighting. EASY TO INSTALL All PerfectSense products come with easy to understand installation instructions and wiring guides to quickly complete the line and low voltage connections. Intelligent out of the box presets provide accurate sensing and detection sensitivities for most applications, making the installation process even faster. EASY ENERGY SAVINGS Cost-effectively save 20-80% of area lighting costs by installing occupancy sensors throughout a facility. Perhaps the most cost effective controls strategy, occupancy sensors begin saving energy the day they are installed. EASY CODE COMPLIANCE Meet and exceed today’s stringent energy codes and performance requirements such as ASHRAE 90.1 2010, IECC 2012 and California Title 24 quickly and easily. EASY SAFETY & SATISFACTION PerfectSense employs the latest sensing technologies and manufacturing methods to provide customers with a superior performing product. Backed by a 5-year limited warranty all products are designed to provide a solution which increases energy savings while delivering occupant satisfaction. EASY TO RETROFIT All PerfectSense products work with every standard commercial lighting load type from all lighting manufacturers, enabling you to bring savings to every building application. VALUABLE TO: BUILDING PROFESSIONALS, ARCHITECTS, SPECIFIERS, SYSTEM INTEGRATORS, ENGINEERS, AND INSTALLERS. Flexibility, simplicity, code compliant, environmentally friendly. BUILDING OWNERS, FACILITY MANAGERS AND PRIVATE CONSUMERS. Energy savings, cost benefits, flexibility and comfort, simplicity, security. 1 PRODUCT SELECTION MATRIX General Information and Product Design Guide Model # Pages Operating Voltage Page 3-10 Description Dual Tech Ultrasonic PIR Switch Occupancy Occupancy Sensors Sensors Wall Switch Page 11-18 Page17-30 Small o ces, small and medium conference rooms, utility / storage rooms Small o ces, small and medium conference rooms, lunch/ breakrooms, utility / storage rooms PS-PWS1277W 11 120/277 PIR Wall Switch 1-Button PS-PWD1277W 11 120/277 PIR Wall Switch 2-Button PS-UWS1277W 13 120/277 Ultrasonic Wall Switch 1-Button Individual restrooms, two-stall restrooms, utility / storage rooms PS-UWD1277W 13 120/277 Ultrasonic Wall Switch 2-Button Individual restrooms, two-stall restrooms, utility / storage rooms PS-DWS1277W 15 120/277 Dual Tech Wall Switch 1-Button Small and executive o ces, small and medium conference rooms, lunch break rooms PS-DWD1277W 15 120/277 Dual Tech Wall Switch 2-Button Small and executive o ces, small and medium conference rooms, lunch break rooms PIR Page17-30 PS-CPS1000 17 24 1000 sq. ft PIR w/ Relay Ultrasonic Ceiling Mount Occupancy Sensors PS-CUS800 19 24 1000 sq. ft 180° view w/ Relay PS-CUS2000 21 24 2000 sq. ft w/ Relay PS-DTC24 23 24 1000 sq. ft PS-DTC24-R 25 24 1000 sq. ft w/ Relay PS-CDS800 27 24 1000 sq. ft 180° view w/ Relay PS-CDS2000 29 24 2000 sq. ft w/ Relay Dual Tech Typical Applications Open o ces, restrooms, conference rooms, hallways, end of aisle Open o ces, restrooms, conference rooms, large o ces, hallways Classrooms, conference rooms, training rooms, large o ces, computer rooms Classrooms, conference rooms, training rooms, large o ces, computer rooms Classrooms, conference rooms, training rooms, large o ces, computer rooms Classrooms, conference rooms, training rooms, large o ces, computer rooms Page 31-36 PIR 31 24 Multi-Lens PIR w/ Relay Ultrasonic O ces, classrooms, hallways, warehouses, aisleways, conference rooms PS-WPS1500 PS-WUS1500 33 24 Ultrasonic w/ Relay Open o ces, classrooms, restrooms, conference rooms, large o ces Dual Tech Wall Mount Occupancy Sensors Small o ces, copy rooms, break rooms, library book stacks, aisleways, small classrooms PS-WDS1500 35 24 Dual Tech w/ Relay Classrooms, conference rooms, training rooms, large o ces, computer rooms Power Packs Page 37-42 PS-PP1277 37 120/277 Basic Power Pack PS-SP24 39 120/277 Auxiliary Power Pack PS-PP7000X 41 120/277 Heavy Duty Power Pack Low Voltage Switches PS-LVSX Auto On, Auto O Allows for added loads Auto On, Auto O , Manual On, Light Hold On, Light Hold O Page 43-44 43 24 Common Stand Alone Control Strategies Low Voltage Series of Switches Manual On / Off control in any location Page 45 2 ENERGY CONSERVATION ENERGY SAVINGS Occupancy sensors deliver maximum energy savings, exceeding the savings provided by other control solutions (i.e. scheduling), by ensuring that lighting is only on when people are present. NexLight, the world’s top producer of design built and easy to use lighting control systems, continues its mission by providing new sensors that save energy and assist in achieving additional design goals. 100% Actual Energy Savings By Application 90% 80% 70% PerfectSense products provide convenient code compliant Automatic-ON or Manual-ON control and are full of innovative features. Our sensors use Passive Infrared (PIR), Ultrasonic, and a combination of the two, commonly referred to as Dual-Technology. Both Automatic-ON and Manual-ON sensors meet the Automatic-OFF requirement of all major energy codes, including ASHRAE 90.1 (2007 and earlier), IECC and California’s Title 24. ASHRAE 90.1-2010 is now including the requirement for many spaces to be Manual-ON. A space may use Automatic-ON control, however the Automatic-ON function cannot turn on more than 50% of the space lighting. Whichever method your space requires, PerfectSense offers a complete selection of compliant solutions. AUTOMATIC-ON + BI-LEVEL CONTROL 60% 50% 40% 30% 20% 20-80% Energy Savings* 10% 0 Classroom Conference Room Private Office Restroom Storage (*Sources: U.S. EPA, Lighting Research Center & California Energy Commission publications) EFFICIENCY INCENTIVES The use of occupancy sensors can assist building owners in earning Corporate Tax Incentives including credits, deductions, exemptions and rebates based on the equipment installed. To qualify, a building must meet or exceed the energy performance required. Visit www.dsireusa.org for more information and updates for your local area. SUSTAINABLE BUILDINGS By designing beyond the requirements of codes, design teams can provide even greater energy savings and work toward sustainable building practices. LEED certification points are awarded with correct application and use of sensors. The result is another way of providing the community with green and energy efficient buildings. 3 ENERGY CODE COMPLIANCE Bi-level switching has the potential to save energy by enabling occupants to use just as much lighting as they want, and is a requirement by EPAct, California’s Title 24 and ASHRAE 90.1 2010. Bi-level Auto-on control is when one zone is turned on automatically (by the sensor) and the other zone must be turned on manually (local switch). This method of control has been shown to use 52% less energy* than Automatic-on only. Additionally, many occupants are comfortable working in lower lighting levels. The result are dramatic energy savings and enhancing occupant comfort. (* Based on California Lighting Technology Center research 2009.) AUTO-ON TO 50% EXAMPLE SENSOR TECHNOLOGIES PerfectSense gives engineers and facility managers more control options than ever before, offering sensors that are the best fit for any application. Sensors featuring Passive Infrared, Ultrasonic or Dual Technology are ideally suited for different applications. Let’s take a closer look at each type. PASSIVE INFRARED Passive Infrared (PIR) technology detects occupancy in the space by sensing the difference between temperatures of a human body in motion and the background space. Requiring a line of sight for detection, PIR sensors feature accurate area coverage cut-offs. ULTRASONIC Ultrasonic (US) technology operates by transmitting an ultrasonic sound wave into the space and measuring the speed at which they return back to the sensor. Occupant movements change the frequency of the waves. This means ultrasonic sensors can detect movement around partitions or indirect line of sight. DUAL TECHNOLOGY Dual Technology operates by combining PIR and ultrasonic detection into a single device. This technology increases the accuracy of detection while decreasing the potential of false ON or false OFF triggers. PIR BEST APPLICATIONS: + Small offices + Warehouses + High ceiling locations + Library book stacks/aisles + Lobby / common areas + Computer rooms ULTRASONIC BEST APPLICATIONS: + Restrooms + Open office spaces + Enclosed hallways + Stairways DUAL TECHNOLOGY BEST APPLICATIONS: + Classrooms + Large conference rooms + Large offices + Lecture halls + Cafeterias 4 APPLICATION EXAMPLES PRIVATE OFFICES In private offices, use a PIR or dual tech sensor depending on room layout and field of view. Take advantage of the integrated light level feature to keep lights off when sufficient daylight is present. REST ROOMS Lighting in restrooms is best controlled with ultrasonic sensors to eliminate hundreds or even thousands of hours of unneeded on-time during a year. A ceiling-mounted ultrasonic senses motion around restroom stalls for greater coverage area. OPEN OFFICES For the open or partitioned office spaces, either the dual tech or ultrasonic type may be appropriate. Wall mounted or on the ceiling, expand coverage of large spaces by linking multiple sensors together to control lighting in a coordinated way. Use these sensors to cover the area in zones with 10-20% overlap as illustrated above. 5 CONFERENCE ROOMS Large conference rooms require detection that will account for occupants that may be still for long periods of time. Dual technology sensors will be able to detect minor motion to keep lights on as long as the space is occupied. CLOSETS / STORAGE Copy rooms, IT rooms, and janitor’s closets are ideal for occupancy based controls. With a wall or switch mounted PIR sensor, lights can be shut off just minutes after the occupant leaves saving hours of wasted lighting energy each day. CLASSROOMS Classrooms large and small require the ability to detect minor motion. Ceiling mounted dual technology sensor models are preferred to get complete room detection. In larger rooms a second sensor and power pack could be added for multizone control. DESIGNING WITH OCCUPANCY SENSORS “Are Occupancy Sensors The Correct Control Strategy For Your Space?” Understanding daily space usage patterns are essential to properly apply occupancy sensing in a commercial building space. If you are able to answer “YES” to some of the following questions, adding occupancy sensors are a viable control option. + Are there periods of time when the space is unoccupied? + Is energy wasted due to lights being left on when no one is in the space? Evaluate Space Needs Install & Con gure Match with Best Technology + Are lights left on after business hours? + Is the space used only intermittently? Layout & Specify + Could some or all area lights be turned off during the day? PerfectSense ® 4 STEP DESIGN PROCESS 1. EVALUATE SPACE NEEDS The following space characteristics are of particular importance because of the influence they have when making a sensor selection: + Room / Space dimensions and shape + Location of main occupant activity + Location of walls, doors, windows and drapes + Location of desks / workspaces and orientation with regard to walls and partitions + Ceiling heights, partition heights and locations + Location of file cabinets, large furniture, large equipment or shelves + Large objects that could block or alter a sensor coverage area + Available daylight for added light level sensing + Make note of high levels of air flow or vibrations noting the location of HVAC ducts and fans 6 2. MATCH SENSING TECHNOLOGY Tip: Choose the sensing technology that best meets space needs and characteristics Occupancy Sensor Technology Selection Matrix Dual Tech Ultrasonic PIR Technology / Product Type Coverage Type Acceptable Application Qualities Unacceptable Application Qualities Very low motion levels by occupants or obstacles blocking sensor view Very low motion levels by occupants or obstacles blocking sensor view Wall Switches Line of sight with clear cuto smaller enclosed spaces Ceiling / Wall Sensors Line of sight with clear cuto spaces where a sensor has a view of activity Wall Switches No clear cuto smaller enclosed spaces High level of air ow Ceiling / Wall Sensors Volumetric in space with no clear cuto open spaces, and spaces with obstacles High ceilings and high levels of vibration or air ow Wall Switches Complete Coverage spaces with low or variable High level of air ow motion levels by occupants Ceiling / Wall Sensors Complete Coverage spaces with low or variable High level of air ow motion levels by occupants Common Locations TIP: Use this reference list to identify the commonly used products for your applications Location Passive Infrared (PIR) Ultrasonic Classroom X Hallway Private O ce X C C X X C,WS Conference Room X X C,WS Open O ces X X C,WM X X C,WM X C,WS X C,WM,WS Lecture Hall Library X X Rest Room 7 Dual Sensor Type Technology C Lobby X Storage X Warehouse X Closet X X WS Cafeteria X X C X C= Ceiling Mount WM= Wall Mount C,WM,WS WS WS= Wall Switch DESIGNING WITH OCCUPANCY SENSORS 3. LAYOUT & SPECIFICATION COVERAGE PATTERNS CHOOSE POWER PACKS Once the technology is chosen, the next step is to select the correct coverage size and shape. A typical design guideline will call for a minimum of 90% coverage area of the square footage in a room. Each product cut sheet includes specific coverage area specifications. Power packs are a necessary component providing three core purposes to most occupancy sensor projects. Power packs provide power to low voltage sensors and other control devices, respond to signals from those devices and switch their internal relays to control the connected loads. It’s important to know the typical use of space. Will occupants be engaged in major motions (walking, using a forklift) or minor motion (reading, typing). Coverage changes depending on motion type. Power packs can also provide advanced features such as switch inputs, inputs for scheduling, and dimming control. Before selecting a power pack, consider the following factors. NEMA TESTING Voltage: Pay attention to the input ratings of each power pack model. PerfectSense understands the importance in producing the highest quality products. When it comes to occupancy sensors, that means producing sensors with consistent detection while reducing False Triggers. All PerfectSense products are designed to meet and exceed the quality and consistency standards set forth in the National Electrical Manufacturers Association guide publication. The NEMA guide establishes two testing parameters as major and minor motion detection. It defines minor motion as the movement of a person sitting at a desk reaching for a telephone, turning the pages of a book, opening a file folder, or picking up a coffee cup. Major motion is defined as the movement of a person walking in or through a space. Low voltage output needs: Typically listed in (mA) be sure the power pack provides enough current to power all of the connected devices for that zone. Relay ratings: Power Packs have specific ratings for different load types (i.e., incandescent, fluorescent, motor). Make sure the relay is rated for the type of load to be controlled and the load being switched does not exceed the load rating of the power pack. To protect against the potentially damaging effects of high inrush current common in newer electronic ballasts, select power packs with zero crossing circuitry technology. Common Features TIP: Use this reference list to identify the desired features for your applications Feature Isolated Relay Light Level Sensing Terminal Wiring Bene t Enables interfacing with facility HVAC, BMS or monitoring systems Increased energy savings in areas with signi cant natural light Simpli ed installation Manual-ON/Auto-ON Options to meet code and maximize energy savings in di erent applications Dual Relays Enables bi-level switching for increased energy savings and code compliance Zero Crossing Reduces stress on sensor relays and increases sensor life LED Operation LED indicators will ash when motion is detected with each technology Low Voltage Flexibility for installation location and wiring Line Voltage No need for power pack device Adaptive Technology Monitors activity patterns over time to auto adjust o time for maximized energy savings Walk-Through Mode Additional energy savings by turning lights o after brief occupancy Alerts Multi-way Capability Lamp Saver Test Mode Audible warning of impending shuto Facilitates control in spaces with multiple entrances For bi-level lighting: alternates the load that turns on each time the lights turn on. Temporary setting used to test coverage area typically expires after 15 minutes Note: not all sensors contain all features, refer to specification for complete details 8 DESIGNING WITH OCCUPANCY SENSORS 4. INSTALL & CONFIGURE INSTALL THE SENSOR During installation contractors should position the sensor so it has the best view of the entire coverage area, while minimizing the possibility of false ON and OFF triggers. Wire sensors according to instructions. This will eliminate any functional problems or sensor damage. If necessary, adjust sensor settings such as the sensitivity, time delay or daylight sensing to match the activity levels of the space being controlled. TIP: Wire according to instructions for proper power pack and sensor function Be sure to increase the off time delay setting for spaces where minor motion and limited activity will be taking place to further reduce the risk of false offs. For increased energy efficiency shorten off time delay settings especially for areas of high traffic. For restrooms, stairwells or areas with limited or no natural lighting use caution and set longer off time delays to ensure occupant safety and security. TIP: Double check specified sensor location prior to installation WIRING POWERPACKS Intelligent power packs provide inputs so that multiple control devices can be connected. This enables customization of control scenarios for different applications and end user preferences. Use intelligent power packs when multi-device, manual switching, and dimming applications are desired. MOUNTING SENSORS PerfectSense products fall into three categories of mounting: Ceiling, Wall, and Wall Switch types. Only wall mount types may be mounted on both the wall or the ceiling. This is important for applications where one of the surfaces may be unsuitable for sensor installation. Most occupancy sensors include an integrated daylight sensor to be used in building spaces that receive daylight. This function is designed to ensure the occupancy sensors will keep lights off in occupied spaces, when the natural daylight coming into the space exceeds the set threshold. If a space has inadequate natural daylight the occupancy sensor will turn lighting on. MOUNTING POWERPACKS PROGRAMMING AND TESTING Power packs are often mounted to the outside of a junction box, placing them in the plenum space, so make sure the power pack is plenum rated. Smaller power packs can be installed inside a standard junction box. 9 PHOTOCELL CONTROLS Make post-installation adjustment as needed. This is not uncommon and is often due to last minute changes in placement of furniture or fixtures. A walk test of the detection area is a common method of ensuring the sensor is located and configured properly for the space. STAND ALONE VS. NETWORKED SYSTEMS INTEGRATING SENSORS WITH CONTROLS Occupancy sensors that operate independently in a space, are referred to as “stand alone” sensors providing no information of occupancy status to other building systems. To increase control and energy savings, PerfectSense low voltage occupancy sensors include isolated Form C relays to seamlessly integrate with Building Management Systems (BMS), HVAC (VAV controllers) or NexLight 2-Wire Lighting Controls Systems. These relays providing real time occupancy status “intelligence” to other systems, adding signifcantly to a building wide control strategy and potential savings. PerfectSense has the industries only sensor with multiple relay outputs for greater connectivity to building controls. NexLight 2-Wire Networked Lighting Control System MULTILAYERED CONTROL STRATEGY For the next level of efficiency, consider combining occupancy sensors with other controls such as lighting control panels or daylight harvesting controls. A multilayered control strategy can assist in meeting energy codes and green sustainability guidelines as well as provide maximized energy savings. Your Source for Design Built Systems PANELS | SWITCHES | SENSORS The images below illustrate an example of how a low voltage sensor could be networked to a building BMS or 2-Wire lighting control system. PerfectSense ® TM Extreme Reliability Lighting Control Systems Room Control with Manual-On + BMS Status Networked Room Control with Manual-On To CPU or Panel 1-Button Low Voltage Switch 2-Wire Switch A A F B E A to BMS or HVAC C A Ceiling Sensor Occupancy / Vacancy Sensor A Power Pack A 2-Wire Panel To CPU or Panel WIRING KEY A E F Line Voltage Class 1 Low Voltage Class 2 (16awg 3-wire) Low Voltage Class 2 (16awg 2-wire) WIRING KEY A Line Voltage Class 1 B Low Voltage Class 2 (NexLight 2-wire Bus) C Low Voltage Class 2 (16awg 4-wire*) * for 50%on/all off commands add one additional wire See page 45 for Stand-Alone Control Scenarios. 10 PerfectSense ® Intelligent Building Occupancy Sensors PS-PWS1277 | PS-PWD1277 Commercial Grade Occupancy Sensor Passive Infrared (PIR) | Wall Switch | Line Voltage Overview • • • • • • • • • • The Commercial Grade PIR Wall Switch Occupancy Sensor provides automatic control of loads by detecting motion and ambient light within the detection area. Sensor features include: One or Two separate relay circuits for independently switching loads (typically lighting loads) ON or OFF. 180° motion detection using passive infrared (PIR) technology. Superior lens design to provide high resolution for detecting major and minor motion. Advanced logic enhances energy savings and user convenience. Convenient pushbuttons for manual control. Automatic adaptive technology adjusts the time delay for maximum energy savings. Automatic 15 second test mode. Service Switch (OFF/Auto/ON). Audible alert 10 seconds before sensor turns loads OFF. Advanced Lamp Saver mode extends the lamp life in 50/50 bi-level lighting applications (2 Circuit model only). PS-PWS1277W PS-PWD1277W Specifications Coverage Area: 1000 sq. ft. Input: 120–277Vac +/-10% 50/60Hz Output: 120Vac - 1000W max. tungsten incandescent load - 1000VA max. ballast load - 1/4 hp max. motor load - No minimum load required 277Vac - 1800 VA max. ballast load - No minimum load required Temperature: 32 to 122°F (0 to 50°C) Humidity: 0% to 90% RH non-condensing Time Delay: Initial Minimum: 5, 10, 15, or 30 minutes Test mode: 15 seconds Walk through mode: 2 minutes if no activity is detected after 30 seconds 11 Phone: 218.828.3700 Compliances: Light level Adjustment: Detection: Audible alert: Service Switch: Manual operation: Lens: Relay Switching: Dimensions: www.nexlight.com UL and cUL Listed Title 24 Compliant FCC part 15 (Class B) 0.5 to 250 footcandles (FC) 180° passive infrared (PIR) Selectable OFF/Auto/ON Pushbutton ON/OFF Impact resistant 0° +/- 500uS (H x W x D): 4.1 x 1.7 x 1.9in. (104 x 44 x 49mm) Fax: 218.824.1568 Detection Range and Coverage Area Both models provide major motion detection up to 1000 sq. ft., and minor motion detection up to 300 sq. ft. NOTE: Coverage area may vary depending upon the shape, size, and absorbent properties of the room. Wiring Diagram- 1 Circuit Order Information- Wall Switch Series PS - P W Technology D= Dual Tech U= Ultrasonic P= Passive Infrared (PIR) S 1277 X Power 1277= Line Voltage Color Mounting W= Wall Switch Circuits S= Single (1) D= Dual (2) W= White I= Ivory L= Light Almond G= Gray B= Black Wiring Diagrams- 2 Circuits Color Reference: BK = Black GN = Green R = Red BL = Blue BR = Brown Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 12 PerfectSense ® Intelligent Building Occupancy Sensors PS-UWS1277 | PS-UWD1277 Commercial Grade Occupancy Sensor Ultrasonic Technology | Wall Switch | Line Voltage Overview • • • • • • • • • The Ultrasonic Wall Switch Occupancy Sensor provides automatic control of lighting by detecting motion and ambient light within the detection area. Sensor features include: One or Two separate relay circuits for independently switching loads (typically lighting loads) ON or OFF 180° motion detection using ultrasonic (US) technology. Superior ultrasonic transducers provide high resolution for detecting major and minor motion. Advanced logic enhances energy savings and user convenience. Convenient pushbutton for manual control. Automatic adaptive technology adjusts the time delay for maximum energy savings. Automatic 15 second test mode. Service Switch (OFF/Auto/ON). Audible alert 10 seconds before sensor turns loads OFF. Advanced Lamp Saver mode extends the lamp life in 50/50 bi-level lighting applications (2 Circuit model only). PS-UWS1277W PS-UWD1277W Specifications Coverage Area: 500 sq. ft. Input: 120–277Vac +/-10% 50/60Hz Output: 120Vac - 1000W max. tungsten incandescent load - 1000VA max. ballast load - 1/4 hp max. motor load - No minimum load required 277Vac - 1800 VA max. ballast load - No minimum load required Temperature: 32 to 122°F (0 to 50°C) Humidity: 0% to 90% RH non-condensing Time Delay: Initial Minimum: 5, 10, 15, or 30 minutes Test mode: 15 seconds Walk through mode: 2 minutes if no activity is detected after 30 seconds 13 Phone: 218.828.3700 Compliances: Light level Adjustment: Detection: Audible alert: Service Switch: Manual operation: Lens: Ultrasonic Transducer: Relay Switching: Dimensions: www.nexlight.com UL and cUL Listed Title 24 Compliant FCC part 15 (Class B) 0.5 to 250 footcandles (FC) 180° ultrasonic (US) Selectable OFF/Auto/ON Pushbutton ON/OFF Impact resistant 40kHz 0° +/- 500uS (H x W x D): 4.1 x 1.7 x 1.9in. (104 x 44 x 49mm) Fax: 218.824.1568 Detection Range and Coverage Area Both models provide major motion detection up to 500 sq. ft., and minor motion detection up to 300 sq. ft. NOTE: Coverage area may vary depending upon the shape, size, and absorbent properties of the room. Wiring Diagram- 1 Circuit Order Information- Wall Switch Series PS - U W S 1277 X Technology Power D= Dual Tech U= Ultrasonic P= Passive Infrared (PIR) 1277= Line Voltage Color Mounting W= White I= Ivory L= Light Almond G= Gray B= Black W= Wall Switch Circuits S= Single (1) D= Dual (2) Wiring Diagrams- 2 Circuits Color Reference: BK = Black GN = Green R = Red BL = Blue BR = Brown Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 14 PerfectSense ® Intelligent Building Occupancy Sensors PS-DWS1277 | PS-DWD1277 Commercial Grade Occupancy Sensor Dual Technology | Wall Switch | Line Voltage Overview • • • • • • • • • PS-DWS1277W The Dual Technology Wall Switch Occupancy Sensor provides automatic control of lighting by detecting motion and ambient light within the detection area. Sensor features include: One or Two separate relay circuits for independently switching loads (typically lighting loads) ON or OFF 180° motion detection using passive infrared (PIR) and ultrasonic technology. Superior lens design and ultrasonic transducers to provide high resolution for detecting major and minor motion. Advanced logic enhances energy savings and user convenience. Convenient pushbutton for manual control. Automatic adaptive technology adjusts the time delay for maximum energy savings. Automatic 15 second test mode. Service Switch (OFF/Auto/ON). Audible alert 10 seconds before sensor turns loads OFF. Advanced Lamp Saver mode extends the lamp life in 50/50 bi-level lighting applications (2 Circuit model only). PS-DWD1277W Specifications Coverage Area: 1000 sq. ft. Input: 120–277Vac +/-10% 50/60Hz Output: 120Vac - 1000W max. tungsten incandescent load - 1000VA max. ballast load - 1/4 hp max. motor load - No minimum load required 277Vac - 1800 VA max. ballast load - No minimum load required Temperature: 32 to 122°F (0 to 50°C) Humidity: 0% to 90% RH non-condensing Time Delay: Initial Minimum: 5, 10, 15, or 30 minutes Test mode: 15 seconds Walk through mode: 2 minutes if no activity is detected after 30 seconds 15 Phone: 218.828.3700 Compliances: Light level Adjustment: Detection: Audible alert: Service Switch: Manual operation: Lens: Ultrasonic Transducer: Relay Switching: Dimensions: www.nexlight.com UL and cUL Listed Title 24 Compliant FCC part 15 (Class B) 0.5 to 250 footcandles (FC) 180° passive infrared (PIR) Selectable OFF/Auto/ON Pushbutton ON/OFF Impact resistant 40kHz 0° +/- 500uS (H x W x D): 4.1 x 1.7 x 1.9in. (104 x 44 x 49mm) Fax: 218.824.1568 Detection Range and Coverage Area Both models provide major motion detection up to 1000 sq. ft., and minor motion detection up to 300 sq. ft. NOTE: Coverage area may vary depending upon the shape, size, and absorbent properties of the room. Wiring Diagram- 1 Circuit Order Information- Wall Switch Series PS - D W Technology D= Dual Tech U= Ultrasonic P= Passive Infrared (PIR) S 1277 X Power 1277= Line Voltage Color Mounting W= Wall Switch Circuits S= Single (1) D= Dual (2) W= White I= Ivory L= Light Almond G= Gray B= Black Wiring Diagrams- 2 Circuits Color Reference: BK = Black GN = Green R = Red BL = Blue BR = Brown Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 16 PerfectSense ® Intelligent Building Occupancy Sensors PS-CPS1000 Standard Range 360˚ Sensor PIR Detection | Ceiling Mount | Low Voltage Overview The Ceiling-mounted Passive Infrared (PIR) Occupancy Sensor accurately detects occupancy and automatically switches lighting on and off as needed. This low profile sensor is ceiling mounted for superior motion detection. With a 360 degree field of view and up to 1000 square feet of coverage area, the Ceiling-mounted PIR Occupancy Sensor is ideal for offices, conference rooms and hallways. Ceiling-mount sensors also incorporate an integral light level sensor to prevent lighting from switching On when sufficient ambient light is present, such as is commonly found in windowed areas. Installation and configuration is simple. The sensor readily mounts to drop ceilings and features front located adjustments for setting sensitivity and time delay. Features an isolated relay for use with building automation, security and HVAC systems. Features Phone: 218.828.3700 Electrical: Power Requirements: 24VDC, from powerpack Current Consumption: 21mA Isolated Relay: Form C Contacts for Class 2 signaling 1A @24VDC Resistive Output: 24VDC active high logic control signal with short circuit protection Controls: • 1000 sq. ft. coverage area • 360 degree field of view • Light level sensing (from 0.5 to 250 foot-candles) • Adjustable time delay (pre-set time delays from 15 seconds to 30 minutes) • Automatic adaptive technology adjusts the time delay for maximum energy savings. • Adjustable sensitivity (from 60 to 100%) • Isolated relay • Red LED motion indicator blinks to indicate motion detection • Adjustment compartment cover equipped with retention feature • Manual bypass • UL®/cUL Listed • Title 24 Certified • Meets ASHRAE 90.1 requirements • Five-year warranty 17 Specifications Passive Infrared Sensitivity: 600-1000 sq. ft Adjustable Sensitivity of (60-100% of Max. Coverage) Time Delay: 15 sec. - 30 min. Light Sensor: 0.5-250 foot candles Load Rating: Controls Class 2 Power Pack Housing Material: High-Impact ABS Color: White Environment Temperature: 32ºF to 122ºF Humidity: 0-90% Non Condensing Installation: See Install Instructions Dimensions: Diameter 4.5 in Height 1.75 in www.nexlight.com Fax: 218.824.1568 Ordering Information COVERAGE* COLOR NA 360˚ 1000sf White 40kHz 360˚ 1000sf White 40kHz 360˚ 1000sf White PS-CUS800 40kHz 180˚ 1000sf White PS-CDS800 40kHz 180˚ 1000sf White PS-CUS2000 40kHz 360˚ 2000sf White PS-CDS2000 40kHz 360˚ 2000sf White DESCRIPTION CATALOG # PIR Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CPS1000 Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor PS-DTC24 Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-DTC24-R Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay OPERATING FREQUENCY Power Pack (Required for operation) *all coverage areas are based on a standard 9 ft mounting height Detection Range and Coverage Area PIR Sensor Field of View Hot COMMON CONTROL RED BLACK BLUE 277V 120V +24v SENSOR Neutral GREEN (N.C.) YELLOW (COMMON) ORANGE (N.O) Wiring Diagrams PS-PP1277 Power Pack BLACK WHITE RED LOAD * Control power must be provided by PerfectSense Power Pack PS-PP1277 or an approved equivalent. Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 18 PerfectSense ® Intelligent Building Occupancy Sensors PS-CUS800 Standard Range 180˚ Sensor Ultrasonic Technology | Ceiling Mount | Low Voltage Overview The 180 Degree Ceiling-Mounted Occupancy Sensors are ideal for use in business and office settings to accurately detect occupancy and automatically control lighting. The ceiling-mount design of these low-profile sensors allows the greatest possible motion sensitivity. An adjustment panel is conveniently located on the front of the sensor, providing ready access to setting controls after the sensor is installed. These occupancy sensors are available in the ultrasonic and dual technology models. The dual technology model employs passive infrared (PIR) and ultrasonic technology. Installation and configuration is simple. The sensor readily mounts to drop ceilings and features front located adjustments for setting sensitivity and time delay. Features an isolated relay for use with building automation, security and HVAC systems. Power Requirements: 24VDC, from powerpack Current Consumption: 30mA Isolated Relay: Form C Contacts for Class 2 signaling 1A @24VDC Resistive Output: 24VDC active high logic control signal with short circuit protection Passive Infrared Sensitivity: 600-1000 sq. ft • 1000 sq. ft. coverage area • 180° degree field of view • Light level sensing (from 0.5 to 250 foot-candles) • Adjustable time delay (pre-set time delays from 15 seconds to 30 minutes) • Automatic adaptive technology adjusts the time delay for maximum energy savings. • Adjustable sensitivity (from 60 to 100%) • Isolated relay •LED motion indicator • Adjustment compartment cover equipped with retention feature • Manual bypass • UL®/cUL Listed • Title 24 Certified • Meets ASHRAE 90.1 requirements • Five-year warranty Phone: 218.828.3700 Electrical: Controls: Features 19 Specifications Adjustable Sensitivity of (60-100% of Max. Coverage) Time Delay: 15 sec. - 30 min. Light Sensor: 0.5-250 foot candles Load Rating: Controls Class 2 Power Pack Housing Material: High-Impact ABS Color: White Environment Temperature: 32ºF to 122ºF Humidity: 0-90% Non Condensing Installation: See Install Instructions Dimensions: Diameter 4.5 in Height 1.75 in www.nexlight.com Fax: 218.824.1568 Ordering Information COVERAGE* COLOR 180˚ 1000sf White 40kHz 180˚ 1000sf White NA 360˚ 1000sf White PS-DTC24 40kHz 360˚ 1000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-DTC24-R 40kHz 360˚ 1000sf White Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS2000 40kHz 360˚ 2000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS2000 40kHz 360˚ 2000sf White DESCRIPTION CATALOG # OPERATING FREQUENCY Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor PS-CUS800 40kHz Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS800 PIR Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CPS1000 Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor Power Pack (Required for operation) *all coverage areas are based on a standard 9 ft mounting height Detection Range and Coverage Area Ultrasonic Sensor Field of View Hot +24v SENSOR COMMON CONTROL RED BLACK BLUE Neutral 277V 120V GREEN (N.C.) YELLOW (COMMON) ORANGE (N.O) Wiring Diagrams PS-PP1277 Power Pack BLACK WHITE RED LOAD * Control power must be provided by PerfectSense Power Pack PS-PP1277 or an approved equivalent. Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 20 PerfectSense ® Intelligent Building Occupancy Sensors PS-CUS2000 Standard Range 360˚ Sensor Ultrasonic Detection | Ceiling Mount | Low Voltage Overview The Ceiling-mounted Ultrasonic Occupancy Sensor accurately detects occupancy and automatically switches lighting on and off as needed. This low profile sensor is ceiling mounted for superior motion detection. With a 360 degree field of view and up to 2000 square feet of coverage area, the Ceiling-mounted Ultrasonic Occupancy Sensor is ideal for storage rooms, bathrooms, conference rooms, classrooms, hallways, and open office areas. Ceiling-mount sensors also incorporate an integral light level sensor to prevent lighting from switching On when sufficient ambient light is present, such as is commonly found in windowed areas. Installation and configuration is simple. The sensor readily mounts to drop ceilings and features front located adjustments for setting sensitivity and time delay. Features an isolated relay for use with building automation, security and HVAC systems. Power Requirements: 24VDC, from powerpack Current Consumption: 34mA Nominal (125mA max) Isolated Relay: Form C Contacts for Class 2 signaling 1A @24VDC Resistive Output: 24VDC active high logic control signal with short circuit protection Adjustable Sensitivity of (60-100% of Max. Coverage) • 2000 sq. ft. coverage area • 360 degree field of view • Light level sensing (from 0.5 to 250 foot-candles) • Adjustable time delay (pre-set time delays from 15 seconds to 30 minutes) • Automatic adaptive technology adjusts the time delay for maximum energy savings. • Adjustable sensitivity (from 60 to 100%) • Isolated relay • Red LED motion indicator blinks to indicate motion detection • Adjustment compartment cover equipped with retention feature • Manual bypass • UL®/cUL Listed • Title 24 Certified • Meets ASHRAE 90.1 requirements • Five-year warranty Phone: 218.828.3700 Electrical: Controls: Features 21 Specifications Time Delay: 15 sec. - 30 min. Light Sensor: 0.5-250 foot candles Load Rating: Controls Class 2 Power Pack Housing Material: High-Impact ABS Color: White Environment Temperature: 32ºF to 122ºF Humidity: 0-90% Non Condensing Installation: See Install Instructions Dimensions: Diameter 4.5 in Height 1.25 in www.nexlight.com Fax: 218.824.1568 Ordering Information COVERAGE* COLOR 40kHz 360˚ 2000sf White PS-CDS2000 40kHz 360˚ 2000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor PS-DTC24 40kHz 360˚ 1000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-DTC24-R 40kHz 360˚ 1000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS800 40kHz 180˚ 1000sf White Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS800 40kHz 180˚ 1000sf White PIR Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CPS1000 NA 360˚ 1000sf White DESCRIPTION CATALOG # Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS2000 Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay OPERATING FREQUENCY Power Pack (Required for operation) *all coverage areas are based on a standard 9 ft mounting height Detection Range and Coverage Area Field of View (Top) Hot +24v SENSOR COMMON CONTROL RED BLACK BLUE Neutral 277V 120V Wiring Diagrams PS-PP1277 Power Pack BLACK WHITE RED LOAD * Control power must be provided by PerfectSense Power Pack PS-PP1277 or an approved equivalent. Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 22 PerfectSense ® Intelligent Building Occupancy Sensors PS-DTC24 Standard Range 360˚ Sensor Dual Technology | Ceiling Mount | Low Voltage Overview: The PS-DTC24 increases area lighting energy efficiency quickly and easily by combining industry leading Passive Infrared (PIR) technology with Ultrasonic for superior detection. Factory preset to deliver significant savings out of the box, this sensor has additional options to further increase energy savings if desired. The PerfectSense PS-DTC24 is a low-voltage sensor that works with PerfectSense class 2 power supply (PSPP1277), to automatically control lighting. The sensor turns the lights on and keeps them on when occupancy is detected and will turn the lights off after the delayed-off time has expired. Operation: The sensor first sees motion using the PIR detection and then activates Ultrasonic to confirm and indicate continued occupancy. The standard factory programming is set to meet the standards of most common area applications with a 10 minute off delay time. Additional Operational Features: Walk-Through Mode: useful when a room is momentarily occupied, like a storage area. When a person enters the room, the lights turn on. If the person leaves the room before the 2.5 minute walk-through timer expires the sensor will turn the lights off. If the person stays in the room longer than 2.5 minutes the sensor will proceed to standard operation. Single-Tech Mode: Only one technology is active in this mode. Dip switch selectable, a user may determine that the space may only require one technology to properly detect the area. One sensor model can now act as a PIR only, Ultrasonic only or Dual-tech sensor. Daylight Sensor: The integrated daylight sensor allows for ambient light override functionality. If this setting is enabled, the controlled lighting load will only turn on if the ambient light present is less than the preset level. Adaptive Learning: Patented adaptive learning technology will automatically increase or decrease the off delay time in response to the occupancy and environmental conditions of the area over a period of time. For example, if there is frequent motion detection, the sensor will automatically shorten the off delay time to better meet the conditions of the room. This technology also detects false off conditions. If this happens, the off delay time duration will immediately be lengthened to avoid future false off conditions. 23 Phone: 218.828.3700 Specifications Features 360˚ Coverage Pattern TM 100% Digital Multiview PIR Dual technology uses PIR + U/S Superior RF immunity Adjustable Time Delay (30 sec-30 min) Single Technology Mode TM SmartSense Adapt Mode Walk Through Mode Daylight Override Mode Simple Test Mode Mounts in drop ceilings and solid ceilings LED’s provide indication of occupancy sensing Electrical: Power Requirements: 24VDC, from powerpack Current Consumption: 30mA Output: 24VDC active high logic control signal with short circuit protection Wiring Diagram: See Fig. 2 Controls: Passive Infrared Sensitivity: 0-100% (Factory Set 50%) Ultrasonic Sensitivity: 0-100% (Factory Set 50%) Light Sensor: 20-320 LUX (Factory Disables) Detection Range: See Fig. 1 Load Rating: Controls Class 2 Power Pack Housing Material: High-Impact ABS Color: White Environment Temperature: 14ºF to 122ºF Humidity: 0-95% Non Condensing Installation: See Install Instructions Dimensions: Diameter 4.33 in Height 2.2 in Supported with a limited 5-year warranty Title 24 Compliant Meets ASHRAE 90.1 requirements www.nexlight.com Fax: 218.824.1568 Ordering Information DESCRIPTION CATALOG # OPERATING FREQUENCY COVERAGE* COLOR White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor PS-DTC24 40kHz 360˚ 1000sf Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS2000 40kHz 360˚ 2000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS2000 40kHz 360˚ 2000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-DTC24-R 40kHz 360˚ 1000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS800 40kHz 180˚ 1000sf White Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS800 40kHz 180˚ 1000sf White PIR Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CPS1000 NA 360˚ 1000sf White Power Pack (Required for operation) *all coverage areas are based on a standard 9 ft mounting height Detection Range and Coverage Area Field of View (Top) TOP VIEW SIDE VIEW 38 ft. 0ft 0m 8 2.4 10 3 12 3.7 24 ft. 12 ft. 26 ft. 7.3 5.5 3.7 1.8 0m 1.8 3.7 5.5 7.3 24 18 12 6 0ft 6 12 18 24 DETECTION AREA PIR Minor Motion PIR Major Motion Ultrasonic Minor Motion Ultrasonic Major Motion 26 ft. 32 ft. Wiring Diagrams +24v SENSOR COMMON CONTROL Phone: 218.828.3700 RED BLACK BLUE Neutral 277V 120V Hot PS-PP1277 Power Pack www.nexlight.com BLACK WHITE RED LOAD Fax: 218.824.1568 24 PerfectSense ® Intelligent Building Occupancy Sensors PS-DTC24-R Standard Range 360˚ Sensor Dual Technology | Ceiling Mount | Low Voltage Overview: The PS-DTC24-R increases area lighting energy efficiency quickly and easily by combining industry leading Passive Infrared (PIR) technology with Ultrasonic for superior detection. Provides 2 SPDT 1 Amp, 30 VDC Form C relay contacts for integration with Nexlight Full 2-Way system and BMS systems. Factory preset to deliver significant savings out of the box, this sensor has additional options to further increase energy savings if desired. The PerfectSense PS-DTC24-R is a low-voltage sensor that works with PerfectSense class 2 power supply (PSPP1277), to automatically control lighting. The sensor turns the lights on and keeps them on when occupancy is detected and will turn the lights off after the delayed-off time has expired. Features The sensor first sees motion using the PIR detection and then activates Ultrasonic to confirm and indicate continued occupancy. The standard factory programming is set to meet the standards of most common area applications with a 10 minute off delay time. 360˚ Coverage Pattern TM 100% Digital Multiview PIR Dual technology uses PIR + U/S Superior RF immunity Adjustable Time Delay (30 sec-30 min) Single Technology Mode TM SmartSense Adapt Mode Walk Through Mode Daylight Override Mode Simple Test Mode Mounts in drop ceilings and solid ceilings LED’s provide indication of occupancy sensing Additional Operational Features: Electrical: Operation: Walk-Through Mode: useful when a room is momentarily occupied, like a storage area. When a person enters the room, the lights turn on. If the person leaves the room before the 2.5 minute walk-through timer expires the sensor will turn the lights off. If the person stays in the room longer than 2.5 minutes the sensor will proceed to standard operation. Single-Tech Mode: Only one technology is active in this mode. Dip switch selectable, a user may determine that the space may only require one technology to properly detect the area. One sensor model can now act as a PIR only, Ultrasonic only or Dualtech sensor. Daylight Sensor: The integrated daylight sensor allows for ambient light override functionality. If this setting is enabled, the controlled lighting load will only turn on if the ambient light present is less than the preset level. Adaptive Learning: Patented adaptive learning technology will automatically increase or decrease the off delay time in response to the occupancy and environmental conditions of the area over a period of time. For example, if there is frequent motion detection, the sensor will automatically shorten the off delay time to better meet the conditions of the room. This technology also detects false off conditions. If this happens, the off delay time duration will immediately be lengthened to avoid future false off conditions. 25 Specifications Phone: 218.828.3700 Power Requirements: 24VDC, from powerpack Current Consumption: 30mA Output: 24VDC active high logic control signal with short circuit protection Isolated Relays: 2 SPDT 1 Amp, 30 VDC Form C Wiring Diagram: See Fig. 2 Controls: Passive Infrared Sensitivity: 0-100% (Factory Set 50%) Ultrasonic Sensitivity: 0-100% (Factory Set 50%) Light Sensor: 20-320 LUX (Factory Disables) Detection Range: See Fig. 1 Load Rating: Controls Class 2 Power Pack Housing Material: High-Impact ABS Color: White Environment Temperature: 14ºF to 122ºF Humidity: 0-95% Non Condensing Installation: See Install Instructions Dimensions: Diameter 4.33 in Height 2.2 in Supported with a limited 5-year warranty Title 24 Compliant Meets ASHRAE 90.1 requirements www.nexlight.com Fax: 218.824.1568 Ordering Information DESCRIPTION CATALOG # Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-DTC24-R Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS2000 Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS2000 COVERAGE* COLOR 40kHz 360˚ 1000sf White 40kHz 360˚ 2000sf White 40kHz 360˚ 2000sf White OPERATING FREQUENCY Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor PS-DTC24 40kHz 360˚ 1000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS800 40kHz 180˚ 1000sf White Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS800 40kHz 180˚ 1000sf White PIR Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CPS1000 NA 360˚ 1000sf White Power Pack (Required for operation) *all coverage areas are based on a standard 9 ft mounting height Detection Range and Coverage Area Field of View (Top) TOP VIEW SIDE VIEW 38 ft. 0ft 0m 8 2.4 10 3 12 3.7 24 ft. 12 ft. 26 ft. 7.3 5.5 3.7 1.8 0m 1.8 3.7 5.5 7.3 24 18 12 6 0ft 6 12 18 24 DETECTION AREA PIR Minor Motion PIR Major Motion Ultrasonic Minor Motion Ultrasonic Major Motion 26 ft. 32 ft. Hot +24v COMMON CONTROL PS-PP1277 Power Pack BLACK WHITE RED LOAD NORMALLY OPEN COMMON NORMALLY CLOSED SENSOR RED BLACK BLUE Neutral 277V 120V NORMALLY CLOSED COMMON NORMALLY OPEN Wiring Diagrams Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 26 PerfectSense ® Intelligent Building Occupancy Sensors PS-CDS800 Standard Range 180˚ Sensor Dual Technology | Ceiling Mount | Low Voltage Overview The 180 Degree Ceiling-Mounted Occupancy Sensors are ideal for use in business and office settings to accurately detect occupancy and automatically control lighting. The ceiling-mount design of these low-profile sensors allows the greatest possible motion sensitivity. An adjustment panel is conveniently located on the front of the sensor, providing ready access to setting controls after the sensor is installed. These occupancy sensors are available in the ultrasonic and dual technology models. The dual technology model employs passive infrared (PIR) and ultrasonic technology. Installation and configuration is simple. The sensor readily mounts to drop ceilings and features front located adjustments for setting sensitivity and time delay. Features an isolated relay for use with building automation, security and HVAC systems. Power Requirements: 24VDC, from powerpack Current Consumption: 33mA Isolated Relay: Form C Contacts for Class 2 signaling 1A @24VDC Resistive Output: 24VDC active high logic control signal with short circuit protection Passive Infrared Sensitivity: 600-1000 sq. ft • 1000 sq. ft. coverage area • 180° degree field of view • Light level sensing (from 0.5 to 250 foot-candles) • Adjustable time delay (pre-set time delays from 15 seconds to 30 minutes) • Automatic adaptive technology adjusts the time delay for maximum energy savings. • Adjustable sensitivity (from 60 to 100%) • Isolated relay •LED motion indicator • Adjustment compartment cover equipped with retention feature • Manual bypass • UL®/cUL Listed • Title 24 Certified • Meets ASHRAE 90.1 requirements • Five-year warranty Phone: 218.828.3700 Electrical: Controls: Features 27 Specifications Adjustable Sensitivity of (60-100% of Max. Coverage) Time Delay: 15 sec. - 30 min. Light Sensor: 0.5-250 foot candles Load Rating: Controls Class 2 Power Pack Housing Material: High-Impact ABS Color: White Environment Temperature: 32ºF to 122ºF Humidity: 0-90% Non Condensing Installation: See Install Instructions Dimensions: Diameter 4.5 in Height 1.75 in www.nexlight.com Fax: 218.824.1568 Ordering Information COVERAGE* COLOR 40kHz 180˚ 1000sf White 40kHz 360˚ 2000sf White PS-CDS2000 40kHz 360˚ 2000sf White PS-DTC24 40kHz 360˚ 1000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-DTC24-R 40kHz 360˚ 1000sf White Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS800 40kHz 180˚ 1000sf White PIR Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CPS1000 NA 360˚ 1000sf White DESCRIPTION CATALOG # Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS800 Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS2000 Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor OPERATING FREQUENCY Power Pack (Required for operation) *all coverage areas are based on a standard 9 ft mounting height Detection Range and Coverage Area Dual Technology Sensor Field of View Hot +24v SENSOR COMMON CONTROL RED BLACK BLUE Neutral 277V 120V GREEN (N.C.) YELLOW (COMMON) ORANGE (N.O) Wiring Diagrams PS-PP1277 Power Pack BLACK WHITE RED LOAD * Control power must be provided by PerfectSense Power Pack PS-PP1277 or an approved equivalent. Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 28 PerfectSense ® Intelligent Building Occupancy Sensors PS-CDS2000 Standard Range 360˚ Sensor Dual Technology | Ceiling Mount | Low Voltage Overview The Ceiling-mounted Dual Tech Occupancy Sensor accurately detects occupancy and automatically switches lighting on and off as needed. This low profile sensor is ceiling mounted for superior motion detection. With a 360 degree field of view and up to 2000 square feet of coverage area, the Ceiling-mounted Occupancy Sensor is ideal for storage rooms, bathrooms, conference rooms, classrooms, hallways, and open office areas. Ceiling-mount sensors also incorporate an integral light level sensor to prevent lighting from switching On when sufficient ambient light is present, such as is commonly found in windowed areas. Installation and configuration is simple. The sensor readily mounts to drop ceilings and features front located adjustments for setting sensitivity and time delay. Features an isolated relay for use with building automation, security and HVAC systems. Power Requirements: 24VDC, from powerpack Current Consumption: 37mA Nominal (125mA max) Isolated Relay: Form C Contacts for Class 2 signaling 1A @24VDC Resistive Output: 24VDC active high logic control signal with short circuit protection Adjustable Sensitivity of (60-100% of Max. Coverage) • 2000 sq. ft. coverage area • 360 degree field of view • Light level sensing (from 0.5 to 250 foot-candles) • Adjustable time delay (pre-set time delays from 15 seconds to 30 minutes) • Automatic adaptive technology adjusts the time delay for maximum energy savings. • Adjustable sensitivity (from 60 to 100%) • Isolated relay • LED motion indicator • Adjustment compartment cover equipped with retention feature • Manual bypass • UL®/cUL Listed • Title 24 Certified • Meets ASHRAE 90.1 requirements • Five-year warranty Phone: 218.828.3700 Electrical: Controls: Features 29 Specifications Time Delay: 15 sec. - 30 min. Light Sensor: 0.5-250 foot candles Load Rating: Controls Class 2 Power Pack Housing Material: High-Impact ABS Color: White Environment Temperature: 32ºF to 122ºF Humidity: 0-90% Non Condensing Installation: See Install Instructions Dimensions: Diameter 4.5 in Height 1.25 in www.nexlight.com Fax: 218.824.1568 Ordering Information COVERAGE* COLOR 40kHz 360˚ 2000sf White PS-CUS2000 40kHz 360˚ 2000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor PS-DTC24 40kHz 360˚ 1000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-DTC24-R 40kHz 360˚ 1000sf White Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS800 40kHz 180˚ 1000sf White Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CUS800 40kHz 180˚ 1000sf White PIR Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CPS1000 NA 360˚ 1000sf White DESCRIPTION CATALOG # Dual Tech Ceiling Mounted Low Voltage Occupancy Sensor w/Relay PS-CDS2000 Ultrasonic Ceiling Mounted Low Voltage Occupancy Sensor w/Relay OPERATING FREQUENCY Power Pack (Required for operation) *all coverage areas are based on a standard 9 ft mounting height Detection Range and Coverage Area Field of View (Top) Hot +24v SENSOR COMMON CONTROL RED BLACK BLUE Neutral 277V 120V GREEN (N.C.) YELLOW (COMMON) ORANGE (N.O) Wiring Diagrams PS-PP1277 Power Pack BLACK WHITE RED LOAD * Control power must be provided by PerfectSense Power Pack PS-PP1277 or an approved equivalent. Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 30 PerfectSense ® Intelligent Building Occupancy Sensors PS-WPS1500 Commercial Grade Occupancy Sensor Wall Mounted | Low Voltage | Passive Infrared Overview Wall-Mounted Passive Infrared (PIR) Occupancy Sensor accurately detects occupancy and automatically switches lighting on and off as needed. This sensor is wall- or ceiling-mounted for superior motion detection. The PIR Occupancy Sensor has three interchangeable lenses included for custom coverage patterns. The Wide Angle lens has a 2500 square foot coverage area when the sensor is mounted 8 feet high, the Long Range lens has a 102 linear foot coverage area at 10 ft. high and the High Bay lens has a 54 linear foot coverage area at 30 ft. high. With a 110 degree field of view the Wall-Mounted PIR Occupancy Sensor is ideal for warehouse, business, and office settings. Wall-mount sensors also incorporate an integral light level sensor to prevent lighting from switching On when sufficient ambient light is present, such as is commonly found in windowed areas. Installation and configuration is simple. The sensor readily mounts to walls as well as drop ceilings and features front located adjustments for setting sensitivity and time delay. Features an isolated relay for use with building automation, security, and HVAC systems. Specifications Coverage Areas: (All 3 lenses included) Wide Angle: 2500 sq. ft. @ 8 ft. high Long Range: 102 linear ft. @ 10 ft. high High Bay: 54 linear ft. @ 30 ft. high Field of view: 110° Ambient light level sensing: 0.5 to 250 foot-candles Adjustable Time Delay: Pre-set time delays from 15 seconds to 30 minutes Adjustable sensitivity: 60%-100% independent adjustment for US and PIR Adaptive Technology: Automatically adjusts the time delay for maximum energy savings LED Motion Indicators: Red=PIR motion indicator Current Consumption @ 24Vdc*: 21mA Nominal Isolated Relay: 1A @ 24 Vdc Resistive Operating Temperature: 32 - 122° F (0 - 50° C) Maximum Humidity: 90% RH Non-condensing Standards: UL®/cUL Listed FCC: Part 15, Class B Title 24 Certified 31 Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 PerfectSense Wall Mount Type ® Intelligent Building Occupancy Sensors Detection Range and Coverage Area PIR (PS-WPS1500) Wide Angle Lens Long Range Lens Wiring Color Table High Bay Lens Wiring the Sensor Wire Color Function Black 0 VDC Red +24 VDC Green Isolated contact NC Yellow Isolated contact common Orange Isolated contact NO Blue Control output PS-PP1277 *Confirm the Sensor is connected to the Class 2 side of the Power Pack. Refer to the Power Pack PS-PP1277 Instruction Bulletin for additional information. Ordering Information Description Catalog Number Wall Mounted Dual Technology Occupancy Sensor PS-WDS1500 Wall Mounted PIR Technology Occupancy Sensor PS-WPS1500 Wall Mounted Ultrasonic Technology Occupancy Sensor PS-WUS1500 Power Pack (required) PS-PP1277 Phone: 218.828.3700 www.nexlight.com CLASS 2 DEVICE WIRING ONLY • • Do not reclassify and install as Class 1, 3, or Power and Lighting wiring. To be connected to a Class 2 power source only. • Wiring connections shall be rated suitable for the wire size employed. Failure to follow this instruction can result in personal injury or equipment or property damage. Fax: 218.824.1568 32 PerfectSense ® Intelligent Building Occupancy Sensors PS-WUS1500 Commercial Grade Occupancy Sensor Wall Mounted | Low Voltage | Ultrasonic Type Overview Wall-mounted Ultrasonic Occupancy Sensor accurately detects occupancy and automatically switches lighting on and off as needed. This low profile sensor is wall- or ceiling- mounted for superior motion detection over partitions and other common obstructions. With 1000 square feet of coverage area, the Wall-Mounted Ultrasonic Occupancy Sensor is ideal for storage rooms, hallways, bathrooms, conference rooms, classrooms and open office areas. Wall-mount sensors also incorporate an integral light level sensor to prevent lighting from switching on when sufficient ambient light is present, such as is commonly found in windowed areas. Installation and configuration is simple. The sensor readily mounts to walls or drop ceilings and features front located adjustments for setting sensitivity and time delay. Features an isolated relay for use with building automation, security and HVAC systems. Specifications 33 Coverage Areas: Field of view: Ambient light level sensing: Adjustable Time Delay: Adjustable sensitivity: Adaptive Technology: LED Motion Indicators: Current Consumption @ 24Vdc*: Isolated Relay: 1000 sq. ft. major motion 500 sq. ft. minor motion NA 0.5 to 250 foot-candles Pre-set time delays from 15 seconds to 30 minutes 60%-100% independent adjusment for US and PIR Automatically adjusts the time delay for maximum energy savings Red=PIR motion indicator 34mA Nominal 1A @ 24 Vdc Resistive Operating Temperature: 32 - 122ºF (0 - 50ºC) Maximum Humidity: Standards: 90% RH Non-condensing UL®/cUL Listed FCC: Part 15, Class B Title 24 Certified Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 PerfectSense Wall Mount Type ® Intelligent Building Occupancy Sensors Detection Range and Coverage Area Ultrasonic (PS-WUS1500) CLASS 2 DEVICE WIRING ONLY • • • NOTE: Coverage area may vary depending upon the shape, size, and absorbent properties of the room. Do not reclassify and install as Class 1, 3, or Power and Lighting wiring. To be connected to a Class 2 power source only. Wiring connections shall be rated suitable for the wire size employed. Failure to follow this instruction can result in personal injury or equipment or property damage. Wiring the Sensor Wiring Color Table Wire Color Function Black 0 VDC Red +24 VDC Green Isolated contact NC Yellow Isolated contact common Orange Isolated contact NO Blue Control output PS-PP1277 *Confirm the Sensor is connected to the Class 2 side of the Power Pack. Refer to the Power Pack PS-PP1277 Instruction Bulletin for additional information. Ordering Information Description Catalog Number Wall Mounted Dual Technology Occupancy Sensor PS-WDS1500 Wall Mounted PIR Technology Occupancy Sensor PS-WPS1500 Wall Mounted Ultrasonic Technology Occupancy Sensor PS-WUS1500 Power Pack (required) PS-PP1277 Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 34 PerfectSense ® Intelligent Building Occupancy Sensors PS-WDS1500 Commercial Grade Occupancy Sensor Wall Mounted | Low Voltage | Dual Technology Overview The Wall-Mounted Dual Technology Occupancy Sensor employs both passive infrared (PIR) and ultrasonic technology to accurately detect occupancy and automatically turn on lighting. To reduce the occurrence of false on events, this sensor employs PIR technology to detect major motion. Once lighting has been turned on, it employs highly sensitive PIR and ultrasonic technology to detect minor motion and keep lighting on while areas remain occupied. When the room or area is no longer occupied, the sensor turns off lighting after a pre-set time delay. The low profile sensor is wall-mounted for greatest sensitivity to motion in large areas with obstructions. With a 110º degree field of view and up to 2500 square feet of coverage area when mounted at 8 ft. off the ground, the Wall-mounted Dual Technology Occupancy Sensor is ideal for conference rooms, classrooms, bathrooms, and large office areas. These wall-mount sensors also incorporate an integral light level sensor to prevent lighting from switching On when sufficient ambient light is present, such as is commonly found in windowed areas. Installation and configuration is simple. The sensor readily mounts to walls and drop ceilings and features front located adjustments for setting sensitivity and time delay. The sensor also features an isolated relay for use with building automation and HVAC systems. Specifications 35 Coverage Area: 2500 sq. ft. @ 8 ft. high Field of view: 110° Ambient light level sensing: 0.5 to 250 foot-candles Adjustable Time Delay: Pre-set time delays from 15 seconds to 30 minutes Adjustable sensitivity: 60%-100% independent adjusment for US and PIR LED Motion Indicators: Red=PIR Green= Ultrasonic Manual Bypass: Switch selectable Adjusment cover: Current Consumption @ 24Vdc*: Isolated Relay: Front located 37mA Nominal 1A @ 24 Vdc Resistive Operating Temperature: 32 - 122ºF (0 - 50ºC) Maximum Humidity: Standards: 90% RH Non-condensing UL®/cUL Listed FCC: Part 15, Class B Title 24 Certified Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 PerfectSense Wall Mount Type ® Intelligent Building Occupancy Sensors Detection Range and Coverage Area Wiring the Sensor Dual Technology (PS-WDS1500) PS-PP1277 Wiring Color Table Wire Color Function Black 0 VDC Red +24 VDC Green Isolated contact NC Yellow Isolated contact common Orange Isolated contact NO Blue Control output CLASS 2 DEVICE WIRING ONLY • • • Do not reclassify and install as Class 1, 3, or Power and Lighting wiring. To be connected to a Class 2 power source only. Wiring connections shall be rated suitable for the wire size employed. Failure to follow this instruction can result in personal injury or equipment or property damage. *Confirm the Sensor is connected to the Class 2 side of the Power Pack. Refer to the Power Pack PS-PP1277 Instruction Bulletin for additional information. Ordering Information Description Catalog Number Wall Mounted Dual Technology Occupancy Sensor PS-WDS1500 Wall Mounted PIR Technology Occupancy Sensor PS-WPS1500 Wall Mounted Ultrasonic Technology Occupancy Sensor PS-WUS1500 Power Pack (required) PS-PP1277 Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 36 PerfectSense ® Intelligent Building Occupancy Sensors PS-PP1277 Commercial Grade Power Pack Overview The PerfectSense Power Pack has a line input of 120 or 277 Vac, and a single-pole, single-throw, relay output for the load. A full wave rectifier converts the AC line voltage to 24 Vdc to power a low-voltage sensor via Class 2, plenum-rated wire. The power pack can be mounted inside or outside of an electrical junction box. Be sure to observe all local codes when mounting and wiring a powerpack. Features • • • • • 100 mA power output can supply up to three sensors Single-pole, normally open relay Rated for plenum use Relay rated for maximum 15 A tungsten and 20 A ballast loads Mounts to a standard 4-in. x 4-in. junction box using a 1/2-in., threaded EMT nipple Specifications -20°F to 150°F (-29°C to 65°C) 32°F to 104°F (0°C to 40°C) 90% non-condensing 120 or 277 Vac ± 10%, 60 Hz 24 Vdc Schematic Diagram Hot System Diagram Line voltage 120/277 Vac Hot Red (+24 Vdc) White Neutral Relay Red 37 Voltage selector Transformer Black Load Phone: 218.828.3700 100 mA nominal 1 hp @ 120 V 120 Vac, 60 Hz 15 A tungsten 1800 W 20 A ballast 277 Vac, 60 Hz 20 A ballast Black Line voltage 120/277 Vac Neutral White Control Blue (Control) Control input Override OFF Load www.nexlight.com +24 Vdc Common Red Black (Common) 277V Voltage selector Output Current: Horsepower Rating: Switching Capacity: 120V Storage Temperature: Operating Temperature: Maximum Humidity: AC Power Input: Output Voltage: Blue Blk Red Sensor Fax: 218.824.1568 PerfectSense Power Packs ® Intelligent Building Occupancy Sensors Installation Instructions 1. Provide separate overcurrent protection in accordance with the National Electrical Code® and applicable local codes. 2. Use copper wire only. 3. Confirm that the device rating is proper for your application. 4. Set the voltage selector on the front of the unit to either 120 or 277 V, depending on your application. The unit is shipped with the selector set to 277 V. 5. Mount the power pack to a suitable junction box using the 1/2-in., threaded nipple and lock. The power pack is plenum-rated, and can be mounted to the inside or the outside of a junction box or fixture in a ceiling plenum. 6. Connect the power pack as shown on previous page. Use approved wire nuts for electrical connections. Mounting Examples Line voltage Inside 120V To sensor 277V 120V 277V To sensor Line voltage Outside DANGER To sensor HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH • The power pack must be installed and serviced only by qualified electrical personnel. • Turn off power at the circuit breaker before beginning installation. • Always use a properly rated voltage sensing device to confirm power is off. Failure to follow these instructions will result in death or serious injury. Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 38 PerfectSense ® Intelligent Building Occupancy Sensors PS-SP24 Auxiliary Relay Power Pack Overview The PerfectSense auxiliary relay is similar to the power pack. The auxiliary relay does not supply power, but switches lighting and HVAC loads based on a control signal from the occupancy sensor. Both the power pack and auxiliary relay are housed in a rugged plenum rated enclosure, and rated for lighting and HVAC loads, including electronic ballasts. Flexible mounting scheme allows for installation inside or outside a standard 4”x4”junction box Features • • • • Single-pole, normally open relay Rated for plenum use Relay rated for maximum 15 A tungsten and 20 A ballast loads Mounts to a standard 4-in. x 4-in. junction box using a 1/2-in., threaded EMT nipple Specifications Storage Temperature: Operating Temperature: Maximum Humidity: AC Power Input: Output Voltage: Standards: -20°F to 150°F (-29°C to 65°C) Horsepower Rating: 32°F to 104°F (0°C to 40°C) Switching Capacity: 90% non-condensing 24Vdc / 36mA No Power Supply UL and cUL listed FCC: Part 15, Home and Office use Class B System Diagram 39 Phone: 218.828.3700 1 hp @ 120 V 120 Vac, 60 Hz 15 A tungsten 1800 W 20 A ballast 277 Vac, 60 Hz 20 A ballast Schematic Diagram www.nexlight.com Fax: 218.824.1568 PerfectSense Power Packs ® Intelligent Building Occupancy Sensors Installation Instructions 1. Provide separate overcurrent protection in accordance with the National Electrical Code® and applicable local codes. 2. Use copper wire only. 3. Confirm that the device rating is proper for your application. 4. Mount the power pack to a suitable junction box using the 1/2-in., threaded nipple and lock. The power pack is plenum-rated, and can be mounted to the inside or the outside of a junction box or fixture in a ceiling plenum. 5. Connect the power pack as shown on previous page. Use approved wire nuts for electrical connections. Mounting Examples Line voltage Line voltage To sensor To sensor Inside Outside DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH • The power pack must be installed and serviced only by qualified electrical personnel. • Turn off power at the circuit breaker before beginning installation. • Always use a properly rated voltage sensing device to confirm power is off. Failure to follow these instructions will result in death or serious injury. Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 40 PerfectSense ® Intelligent Building Occupancy Sensors PS-PP7000X Heavy Duty Power Pack Overview Combines transformer relay functions, occupancy sensor control, and manual/automatic operation into a single high performance unit. The PerfectSense Power Pack provides a wide array of switching solutions into a single unit. With high inrush stability circuitry specifically designed to handle today’s demanding inrush from electronic ballast loads and offer unmatched durability. A full wave rectifier converts the AC line voltage to 24 Vdc to power a low-voltage sensor via Class 2, plenum-rated wire. The power pack can be mounted inside or outside of an electrical junction box. Be sure to observe all local codes when mounting and wiring a powerpack. Features • Extreme durability: exceeds WS-896 Federal Specification duty cycle requirements for specification grade toggle switches. • High Inrush Stability circuit designed to handle high inrush electronic ballast loads, including the latest T5HO and T4 ballasts. • Zero crossing design for reliability and extended life. • Mechanical latching relay for dependability and robust for all load types • Return-to-on design provides fail safe operation in the event of power loss or malfunction. • Transformer Relay Function: replaces traditional transformer relays and provides occupancy sensors control. Ideal for use where code requirements/jurisdictions prohibit the use of 277V switch legs. • Manual-ON or Automatic-ON functionality for use in bi-level lighting control per CEC Title 24 requirements. • UL 2043 Plenum Rated • Endurance tested to over 1,000,000 cycles at full load. • Integrates with low voltage momentary and maintained switches to control occupancy sensors. • Conduit adaptor included for low voltage connections. Specifications Storage Temperature: Operating Temperature: Maximum Humidity: AC Power Input: Output Voltage: 41 -20°F to 150°F (-29°C to 65°C) 32°F to 104°F (0°C to 40°C) 90% non-condensing 120 or 277 Vac ± 10%, 60 Hz 24 Vdc Phone: 218.828.3700 Output Current: Horsepower Rating: Switching Capacity: www.nexlight.com 225 mA nominal 1 hp @ 120 V 120 Vac, 60 Hz; 15 A tungsten 1800 W 20 A ballast 277 Vac, 60 Hz; 20 A ballast Fax: 218.824.1568 PerfectSense Power Packs ® Intelligent Building Occupancy Sensors Installation Instructions 1. Provide separate overcurrent protection in accordance with the National Electrical Code® and applicable local codes. 2. Use copper wire only. 3. Confirm that the device rating is proper for your application. 4. Mount the power pack to a suitable junction box using the 1/2-in., threaded nipple and lock. The power pack is plenum-rated, and can be mounted to the inside or the outside of a junction box or fixture in a ceiling plenum. 5. Connect the power pack as shown on previous page. Use approved wire nuts for electrical connections. Bi-Level Switching Diagram N Zone 1 – Auto ON H Yellow Orange Orange/Yellow Black Blue White White/Blue Blue Green Blue Brown/White Local SW 1 Occupancy Sensor Auto ON Brown Red Black +24VDC Com LOAD 1 LOAD 2 Zone 2 – Manual ON Yellow Orange Orange/Yellow Black Blue White White/Blue Blue Green Blue Brown/White Local SW 2 Manual ON Momentary or Maintained Switches Brown Red Black Phone: 218.828.3700 Com www.nexlight.com Fax: 218.824.1568 42 PerfectSense ® Intelligent Building Occupancy Sensors PS-LVSX Series Low Voltage Switches Overview The PerfectSense™ Low Voltage Switches are a series of decorator style push button wall switches that can be mounted in commercial or residential applications. The low voltage switches are designed to operate with PerfectSense Occupancy Sensors and NexLight 2-Wire relay panels. All switch models are available in white, almond, and ivory. Features Provide simple momentary push button control. LED models provide pilot lights or status outputs. Operate on voltage ranges from 5-36 VDC. Certain models are designed for use with NexLight 2-Wire relay panels. Switches fit standard NEMA wall boxes. Decorator-style enclosure; wall plate included. Ordering Information Part Number Description PS-LVS1x 1-button, low voltage switch PS-LVS1Lx 1-button, low voltage switch with LED PS-LVS2x 2-button, low voltage switch PS-LVS2Lx 2-button, low voltage switch with LED PS-LVS1Rx 1-button NexLight 2-Wire relay panel switch with LED PS-LVS2Rx 2-button NexLight 2-Wire relay panel switch with LED x = color code; W for White, L for Light Almond, and I for Ivory. Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 43 PerfectSense Low Voltage Switches Intelligent Building Occupancy Sensors Low Voltage Switch Wiring One Switch PS-LVS1 V OUT Specifications Connection type External wires Gauge: #22 AWG stranded Number of conductors/switch: PS-LVS1: 2 PS-LVS1L: 4 PS-LVS2: 3 PS-LVS2L: 7 PS-LVS1R: 2 PS-LVS2R: 3 Switch Operating Range 5-36VDC Max current of 50mA @ 36VDC LED Operating Range 5-36 VDC Min operating current .150ma @ 5VDC Min operating current .275ma @ 12VDC Min operating current .385ma @ 24VDC Min operating current .470ma @ 36VDC Conductor temperature rating: Not specified, select to meet UL Class 2 requirements Conductor voltage rating: 5 to 36 Volt DC SW1 V IN One Switch with LED V OUT PS-LVS1L (+) Anode SW1 (-) Cathode V IN Two Switches V OUT SW1 ® Conductor length: 6 inches from housing Temperature 0 – 50 degrees C. Humidity Maximum 90% RH non-condensing PS-LVS2 Low Voltage Relay Panel Switch Wiring SW1 One Switch V IN Two Switches PS-LVS1R SW2 V OUT V OUT SW2 Reverse Polarity Switch V OUT SW1 PS-LVS2R Reverse Polarity Switch V IN Two Switches with LEDs V OUT SW1 PS-LVS2L SW1 V IN (+) Anode LED1 Reverse Polarity Switch (-) Cathode LED1 V OUT SW2 V IN SW2 V OUT SW2 (+) Anode LED2 (-) Cathode LED2 Phone: 218.828.3700 www.nexlight.com Fax: 218.824.1568 44 PerfectSense Common Stand Alone Control Strategies ® Intelligent Building Occupancy Sensors Auto On / Auto Off Manual On / Auto Off 1-Button Low Voltage Switch A A F E A E A Ceiling Sensor Ceiling Sensor A Power Pack A Power Pack WIRING KEY A E Line Voltage Class 1 Low Voltage Class 2 (16awg 3-wire) Auto On / Auto Off is the most basic occupancy control strategy. Requiring only a standard power pack and low voltage sensor, the space is controlled based on occupnacy with no manual override control. Line voltage wall switch sensors may also be configured to work in this manner. Consult local codes for using this scenario in approved locations. WIRING KEY E F Low Voltage Class 2 (16awg 3-wire) Low Voltage Class 2 (16awg 2-wire) Manual On / Auto Off is the commonly used method for areas using a single lighting load. Occupants manually turn lights onBe sure to use a PS-PP7000X power pack designed to work with low voltage switches. Manual On / Auto Off + Dimming + Daylight Sensor 50% Manual On / Auto Off 2- Button Low Voltage Switch A Line Voltage Class 1 Low Voltage Switch a b A ab A 1 E B A E E A ab 1 Occupancy / Vacancy Sensor Occupancy / Vacancy Sensor A A ab B 1 Daylight Sensor WIRING KEY Aab Line Voltage Class 1 (3-conductor) E Low Voltage Class 2 (16awg 3-wire) 50% Manual On / Auto Off requires one lighting load to be switched on automatically when occupancy is detected by an occupancy sensor, while a second lighting load can be turned on manually by the occupant if desired. Both loads can then be turned off manually or via the occupancy sensor timing out. Commonly required by building codes (such as California Title 24), this is an easy and convenient method of delivering extra energy savings without inconveniencing the occupant. WIRING KEY A Line Voltage Class 1 E Low Voltage Class 2 (16awg 3-wire) G Low Voltage Class 2 (0-10V control wires) F Low Voltage Class 2 (16awg 2-wire) Going above and beyond Manual On / Auto Off can be done in a number of ways. The addition of photocells for daylight harvesting and or 0-10v dimming are two of the most popular choices for enahnced levels of control and energy savings in locations with large windows, conference rooms, or open office areas. 45 PerfectSense Intelligent Building Occupancy Sensors OUR COMMITMENT TO YOU We take great pride in designing each of our products with the goal of providing the highest accuracy detection performance possible in the price range of that product. We strive to reproduce the consistent performance across all of our products. And we strive to avoid flashy features and promises of auto-commissioning. While that may sound initially attractive to the novice, they are not real and not enduring. In addition, we use only the highest-quality parts and the latest assembly and quality control techniques to ensure the reliability and long life of our products. Our reputation rests on our steadfast pursuit of this policy in sensors and lighting control systems for educational, commercial and industrial applications. At NexLight, we are committed to investing in research that continually gives rise to new technologies for improving energy savings and occupant comfort. When you purchase any product from PerfectSense, we encourage you to compare it, as we do, to competitive products for long-term performance accuracy. We believe that this process will enhance your appreciation of the product you select. With best wishes from all of us at PerfectSense for many years of consistent performance. HOW TO PURCHASE PERFECTSENSE PRODUCTS In order to serve you better, PerfectSense products are available through a number of different sales channels. To get you connected with the right products for your application please contact us directly either by telephone at 218-828-3700, or visit us on the web at www.NexLight.com for more information. PerfectSense ® Intelligent Building Occupancy Sensors PerfectSense is a trademarked brand of NexLight TEL.: 218-828-3700 FAX: 218-824-1568 WWW.NEXLIGHT.COM ® PerfectSense ® Intelligent Building Occupancy Sensors NexLight Lighting Controls 7877 College Road, Suite 105 Baxter, MN, 56425 1-218-828-3700 www.nexlight.com Electrical equipment should be installed, operated, serviced and maintained only by qualified personnel. No responsibility is assumed by NexLight for any consequences arising out of the use of this material. © 2013 NexLight Lighting Controls, All Rights Reserved. Cat# PS.4.13