PerfectSense ® Intelligent Building Occupancy Sensors PS-WUS1500 Commercial Grade Occupancy Sensor Wall Mounted | Low Voltage | Ultrasonic Type Overview Wall-mounted Ultrasonic Occupancy Sensor accurately detects occupancy and automatically switches lighting on and off as needed. This low profile sensor is wall- or ceiling- mounted for superior motion detection over partitions and other common obstructions. With 1000 square feet of coverage area, the Wall-Mounted Ultrasonic Occupancy Sensor is ideal for storage rooms, hallways, bathrooms, conference rooms, classrooms and open office areas. Wall-mount sensors also incorporate an integral light level sensor to prevent lighting from switching on when sufficient ambient light is present, such as is commonly found in windowed areas. Installation and configuration is simple. The sensor readily mounts to walls or drop ceilings and features front located adjustments for setting sensitivity and time delay. Features an isolated relay for use with building automation, security and HVAC systems. Specifications Coverage Areas: Field of view: Ambient light level sensing: Adjustable Time Delay: Adjustable sensitivity: Adaptive Technology: LED Motion Indicators: Current Consumption @ 24Vdc*: Isolated Relay: 1000 sq. ft. major motion 500 sq. ft. minor motion NA 0.5 to 250 foot-candles Pre-set time delays from 15 seconds to 30 minutes 60%-100% independent adjusment for US and PIR Automatically adjusts the time delay for maximum energy savings Red=PIR motion indicator 34mA Nominal 1A @ 24 Vdc Resistive Operating Temperature: 32 - 122ºF (0 - 50ºC) 90% RH Non-condensing UL®/cUL Listed FCC: Part 15, Class B Title 24 Certified Maximum Humidity: Standards: © 2013 NexLight Lighting Controls, All Rights Reserved. Phone: 218.828.3700 www.nexlight.com 1 Fax: 218.824.1568 PerfectSense Intelligent Building Occupancy Sensors Detection Range and Coverage Area Wiring the Sensor Ultrasonic (PS-WUS1500) PS-PP1277 NOTE: Coverage area may vary depending upon the shape, size, and absorbent properties of the room. Wiring Color Table Wire Color Function Black 0 VDC Red +24 VDC Green Isolated contact NC Yellow Isolated contact common Orange Isolated contact NO Blue Control output CLASS 2 DEVICE WIRING ONLY • • Do not reclassify and install as Class 1, 3, or Power and Lighting wiring. To be connected to a Class 2 power source only. • Wiring connections shall be rated suitable for the wire size employed. Failure to follow this instruction can result in personal injury or equipment or property damage. *Confirm the Sensor is connected to the Class 2 side of the Power Pack. Refer to the Power Pack PS-PP1277 Instruction Bulletin for additional information. Ordering Information Description Catalog Number Wall Mounted Dual Technology Occupancy Sensor PS-WDS1500 Wall Mounted PIR Technology Occupancy Sensor PS-WPS1500 Wall Mounted Ultrasonic Technology Occupancy Sensor PS-WUS1500 Power Pack (required) PS-PP1277 © 2013 NexLight Lighting Controls, All Rights Reserved. Phone: 218.828.3700 www.nexlight.com 2 Fax: 218.824.1568 ®