NAC Compatibility - Potter Electric Signal Company, LLC

advertisement
Notification Compatibility Document
St. Louis, MO
(866) 956-0988
www.pottersignal.com
#5403592 - Rev E
01/14
NAC COMPATIBILITY • 5403592 • REV E • 01/14
WARRANTY INFORMATION
The essential purpose of any sale or contract for sale of any of the products listed in the POTTER catalog or
price list is the furnishing of that product. It is expressly understood that in furnishing said product, POTTER
does not agree to insure the Purchaser against any losses the Purchaser may incur, even if resulting from the
malfunction of said product.
POTTER warrants that the equipment herein shall conform to said descriptions as to all affirmation of fact
and shall be free from defects of manufacture, labeling and packaging for a period of one (1), one and one
half (1.5), three (3), or five (5) year'(s), depending on the product, from the invoice date to the original
purchaser, provided that representative samples are returned to POTTER for inspection. The product
warranty period is stated on the exterior of the product package. Upon a determination by POTTER that a
product is not as warranted, POTTER shall, at its exclusive option, replace or repair said defective product
or parts thereof at its own expense except that Purchaser shall pay all shipping, insurance and similar charges
incurred in connection with the replacement of the defective product or parts thereof. This Warranty is void
in the case of abuse, misuse, abnormal usage, faulty installation or repair by unauthorized persons, or if for
any other reason POTTER determines that said product is not operating properly as a result of causes other
than defective manufacture, labeling or packaging.
The Aforesaid Warranty Is Expressly Made In Lieu Of Any Other Warranties, Expressed Or Implied, It
Being Understood That All Such Other Warranties, Expressed Or Implied, Including The Warranties Of
Merchantability And Fitness For Particular Purpose Are Hereby Expressly Excluded. In No Event Shall
Potter Be Liable To Purchaser For Any Direct, Collateral, Incidental Or Consequential Damages In
Connection With Purchaser’s Use Of Any Of The Products Listed Herein, Or For Any Other Cause Whatsoever
Relating To The Said Products. Neither Potter Nor Its Representatives Shall Be Liable To The Purchaser
Or Anyone Else For Any Liability, Claim, Loss, Damage Or Expense Of Any Kind, Or Direct Collateral,
Incidental Or Consequential Damages Relative To Or Arising From Or Caused Directly Or Indirectly By Said
Products Or The Use Thereof Or Any Deficiency, Defect Or Inadequacy Of The Said Products. It Is Expressly
Agreed That Purchaser’s Exclusive Remedy For Any Cause Of Action Relating To The Purchase And/or Use
Of Any Of The Products Listed Herein From Potter Shall Be For Damages, And Potter's Liability For Any And
All Losses Or Damages Resulting From Any Cause Whatsoever, Including Negligence, Or Other Fault, Shall
In No Event Exceed The Purchase Price Of The Product In Respect To Which The Claim Is Made, Or At The
Election Of Potter, The Restoration Or Replacement Or Repair Of Such Product.
Potter Electric Signal Company, LLC
St. Louis, MO • (866) 956-0988
2
NAC COMPATIBILITY • 5403592 • REV E • 01/14
How to Use this Document
As required in ANSI/UL Standard 864, notification circuits that supply synchronized strobe power must show
compatibility with particular devices. In addition, the total number of devices per circuit must be included.
Below is the list of Potter Fire Alarm Control Panels that are UL Listed. The letter next to the column correlates to a
specific Fire Alarm Panel and amount of power.
The following pages contain tables of notification devices by various manufactures. In order to determine the
maximum number of devices that can be connected:
1. Use the Panel Key below to determine the column letter that corresponds to the Panel being used:
Panel Key
Panel
PFC-4410RC Releasing Panel Family (VFR-400, SRX, JFS-C1, Safe
Alarm 4-Z)
PFC-5004E Expandable Fire Alarm Control Panel
PFC-5008 Fire Alarm Control Panel
PFC-8060 Fire Alarm Control Panel
PFC-8500 Fire Alarm Control Panel
PFC-9000 Addressable Fire Alarm Panel
SOM-4 Supervised Output Module
MOM-4 Monitored Output Module
PSN Series Power Supplies
SMD 10-3A Potter/AMSECO Synchronization Module
PFC-6030, PFC-6075, PFC-6075R, PFC-6200, PFCNAC Circuits
6800, PFC-6500(R), P100-P400R
I/O Circuits
Addressable Fire Panel
PFC-6006 Sprinkler Monitoring Panel
Column
Amps per Load
A
1
B
1.5
C
2
D
3
D
3
A
1
E
0.5
2. Go to the page that correlates to the Manufacturer of the horn, strobe, chime, bell, or device that will be
connected to the Panel, and find the specific row for the device:
Manufacturer
Potter/ AMSECO
Gentex
Cooper/Wheelock
System Sensor
Page
4
5
6-7
8
3. Use the column from Step 1, and the device row from Step 2, find the corresponding number of devices per
circuit that can be connected.
3
NAC COMPATIBILITY • 5403592 • REV E • 01/14
Potter/AMSECO
Model
Type
H-1224
HP-25T
SL-1224
SL-1224-WP
CSL-1224W *
SL-24H
SL-24H-WP
SL24C-3075110
SL24C-177
CSL-24C *
SH-1224
SH-1224-WP
CSH-1224-W *
SH-24H
SH-24H-WP
SH24C-3075110
SH24C-177
CM24C
SCM24-3075110
SB24-1530
SB-75110
SC24-30750110
SLB24-75
CSLB24 *
SHB24-75
CSHB24 *
MBA Bell
SMD10-3A
Horn
Horn
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Chime
Strobe/Chime
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Bell
Sync Module
A
B
C
D
Number of Devices.
Refer to the Panel Key.
16
21
31
55
74
111
26
33
49
11
15
22
11
15
22
9
13
19
9
13
19
12
17
25
4
5
7
9
12
18
19
26
39
9
12
18
9
12
18
7
9
13
7
9
13
5
7
10
3
4
6
36
48
72
10
13
19
23
31
46
10
14
21
23
31
46
9
12
18
9
12
18
7
10
15
7
10
15
24
32
48
1
1
1
10
36
16
7
7
6
6
8
2
6
12
6
6
4
4
3
2
24
6
15
6
15
6
6
4
4
16
1
* Not for evacuation
4
E
5
18
8
3
3
3
3
4
1
3
6
3
3
2
2
1
1
12
3
7
3
7
3
3
2
2
8
1
NAC COMPATIBILITY • 5403592 • REV E • 01/14
Gentex
Model
Type
GES3-24
GEC3-24
GCS
GCC
GCS Colored Strobe *
GCC Colored Combo *
GEC
GEC Colored Lens *
GES
GES Colored Lens *
GEH
GX93
WGES24
WGEC24
WGES24 Colored Lens *
WGEC24 Colored Lens *
S-24W
HS-24W
CS-24R
CHS-24R
CCS-24AR
CCHS-24AR*
EH-24R
MHT-1224R
WGES24-75WR
WGEC24-75WR
CS-24WAR
CHS-24AR
Strobe
Strobe/Horn
Strobe
Strobe/Horn
Strobe
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe
Strobe
Horn
Horn
Strobe
Strobe/Horn
Strobe
Strobe/Horn
Strobe
Strobe/Horn
Strobe
Strobe/Horn
Strobe
Strobe/Horn
Horn
Horn
Strobe
Strobe/Horn
Strobe
Strobe/Horn
A
B
12
9
8
6
8
6
9
9
12
12
35
55
5
4
5
4
12
9
8
6
8
6
35
55
5
4
5
4
Number of Devices.
Refer to the Panel Key.
19
25
37
14
18
27
12
16
24
10
13
19
12
16
24
10
13
19
14
18
27
14
18
27
19
25
37
19
25
37
53
71
106
83
111
166
8
11
16
7
9
13
8
11
16
7
9
13
19
25
37
14
18
27
12
16
24
10
13
19
12
16
24
10
13
19
53
71
106
83
111
116
8
11
16
7
9
13
8
11
16
7
9
13
* Not for evacuation
5
C
D
E
6
4
4
3
4
3
4
4
6
6
17
27
2
2
2
2
6
4
4
3
4
3
17
27
2
2
2
2
NAC COMPATIBILITY • 5403592 • REV E • 01/14
Cooper/Wheelock
Model
Type
HN
HNC
HS-24
NH-12/24
AH-24
AH-24WP
MIZ-24S
AMT-12/24
HS
HSC
AS-24MCW
AS-24MCWH
AS-241575W
AS-24MCC
AS-24MCCH
ASWP-2475W
HS4-241575W
HS4-24MCW
HS4-24MCC
HS4-24MCWH
NS-241575W
NS-24MCW
NS-24MCC
NS-24MCCH
ST
STC
RSS-241575W
RSS-24MCW
RSS-24MCC
RSS-24MCWH
RSS-24MCCH
RSSP-241575W
RSSP-24MCW
RSSP-24MCWH
RSSWP-2475W
AMT-241575W
AMT-24MCW
AMT4-241575W-NYC
MT-241575W
Horn
Horn
Horn
Horn
Horn
Horn
Horn
Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
A
20
20
36
22
47
47
38
24
15
15
14
2
10
13
2
6
6
10
10
2
10
14
14
12
17
16
10
16
15
3
3
10
16
3
6
8
12
8
8
6
B
C
D
Number of Devices.
Refer to the Panel Key.
31
42
62
31
42
62
55
74
110
34
45
67
71
95
142
71
95
142
57
76
114
36
48
72
23
30
45
23
30
45
22
29
43
4
5
7
15
20
30
20
27
40
4
5
7
10
13
19
9
12
18
16
21
31
16
21
31
4
6
8
15
20
30
22
30
44
18
28
38
4
6
8
26
35
52
24
32
48
16
22
32
25
33
49
23
30
45
5
6
9
5
6
9
16
22
32
25
33
49
5
6
9
10
14
20
13
18
26
18
25
36
12
17
24
13
17
25
E
10
10
18
11
23
23
19
12
7
7
7
1
5
6
1
3
3
5
5
1
5
7
7
6
8
8
5
8
7
1
1
5
8
1
3
4
6
4
4
NAC COMPATIBILITY • 5403592 • REV E • 01/14
Cooper/Wheelock (continued)
Model
Type
A
B
C
D
E
MT-24MCW
MTWP-2475W
AMT-12/24-NYC
MT-12/24
MT4-12/24
Strobe/Horn
Strobe/Horn
Horn
Horn
Horn
11
6
24
40
25
17
10
36
62
38
23
13
48
80
51
34
19
72
121
76
5
3
12
20
12
7
NAC COMPATIBILITY • 5403592 • REV E • 01/14
System Sensor
Model
Type
HR/HW
HRK/HWK
MH
CHR/CHW
SR/SW
SRH/SWH
SRK/SWK
SRH/SHW
SRHK/SWHK
SCR/SCW
SCRH/SCWH
SCRHK/SCWHK
P2R/P2W
P2RH/P2WH
P2RK/P2WK
P2RHK/P2WHK
PC2R/PC2W
PC2RK/PC2WK
PC2RH/PC2WH
PC2RHK/PC2WHK
P4R/P4W
P4RH/P4WH
PC4R/PC4W
PC4RH
CHSR/CHSW
MDL3R/MDL3W
Horn
Horn
Horn
Chime
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn
Strobe/Horn*
Strobe/Horn*
Strobe/Horn*
Strobe/Horn*
Strobe/Chime
Sync Module
A
B
C
D
Number of Devices.
Refer to the Panel Key.
28
38
57
28
38
57
107
142
214
44
58
88
22
30
45
6
8
13
22
30
45
6
8
13
6
8
13
22
30
45
6
8
13
6
8
13
22
30
45
6
8
13
22
30
45
6
8
13
22
30
45
22
30
45
6
8
13
6
8
13
22
30
45
6
8
13
6
8
13
6
8
13
23
31
46
1
1
1
19
19
71
29
15
4
15
4
4
15
4
4
15
4
15
4
15
15
4
4
15
4
4
4
15
1
* Not for evacuation
8
E
9
9
35
14
7
2
7
2
2
7
2
2
7
2
7
2
7
7
2
2
7
2
2
2
7
1
Download