Notification Compatibility Document St. Louis, MO (866) 956-0988 www.pottersignal.com #5403592 - Rev E 01/14 NAC COMPATIBILITY • 5403592 • REV E • 01/14 WARRANTY INFORMATION The essential purpose of any sale or contract for sale of any of the products listed in the POTTER catalog or price list is the furnishing of that product. It is expressly understood that in furnishing said product, POTTER does not agree to insure the Purchaser against any losses the Purchaser may incur, even if resulting from the malfunction of said product. POTTER warrants that the equipment herein shall conform to said descriptions as to all affirmation of fact and shall be free from defects of manufacture, labeling and packaging for a period of one (1), one and one half (1.5), three (3), or five (5) year'(s), depending on the product, from the invoice date to the original purchaser, provided that representative samples are returned to POTTER for inspection. The product warranty period is stated on the exterior of the product package. Upon a determination by POTTER that a product is not as warranted, POTTER shall, at its exclusive option, replace or repair said defective product or parts thereof at its own expense except that Purchaser shall pay all shipping, insurance and similar charges incurred in connection with the replacement of the defective product or parts thereof. This Warranty is void in the case of abuse, misuse, abnormal usage, faulty installation or repair by unauthorized persons, or if for any other reason POTTER determines that said product is not operating properly as a result of causes other than defective manufacture, labeling or packaging. The Aforesaid Warranty Is Expressly Made In Lieu Of Any Other Warranties, Expressed Or Implied, It Being Understood That All Such Other Warranties, Expressed Or Implied, Including The Warranties Of Merchantability And Fitness For Particular Purpose Are Hereby Expressly Excluded. In No Event Shall Potter Be Liable To Purchaser For Any Direct, Collateral, Incidental Or Consequential Damages In Connection With Purchaser’s Use Of Any Of The Products Listed Herein, Or For Any Other Cause Whatsoever Relating To The Said Products. Neither Potter Nor Its Representatives Shall Be Liable To The Purchaser Or Anyone Else For Any Liability, Claim, Loss, Damage Or Expense Of Any Kind, Or Direct Collateral, Incidental Or Consequential Damages Relative To Or Arising From Or Caused Directly Or Indirectly By Said Products Or The Use Thereof Or Any Deficiency, Defect Or Inadequacy Of The Said Products. It Is Expressly Agreed That Purchaser’s Exclusive Remedy For Any Cause Of Action Relating To The Purchase And/or Use Of Any Of The Products Listed Herein From Potter Shall Be For Damages, And Potter's Liability For Any And All Losses Or Damages Resulting From Any Cause Whatsoever, Including Negligence, Or Other Fault, Shall In No Event Exceed The Purchase Price Of The Product In Respect To Which The Claim Is Made, Or At The Election Of Potter, The Restoration Or Replacement Or Repair Of Such Product. Potter Electric Signal Company, LLC St. Louis, MO • (866) 956-0988 2 NAC COMPATIBILITY • 5403592 • REV E • 01/14 How to Use this Document As required in ANSI/UL Standard 864, notification circuits that supply synchronized strobe power must show compatibility with particular devices. In addition, the total number of devices per circuit must be included. Below is the list of Potter Fire Alarm Control Panels that are UL Listed. The letter next to the column correlates to a specific Fire Alarm Panel and amount of power. The following pages contain tables of notification devices by various manufactures. In order to determine the maximum number of devices that can be connected: 1. Use the Panel Key below to determine the column letter that corresponds to the Panel being used: Panel Key Panel PFC-4410RC Releasing Panel Family (VFR-400, SRX, JFS-C1, Safe Alarm 4-Z) PFC-5004E Expandable Fire Alarm Control Panel PFC-5008 Fire Alarm Control Panel PFC-8060 Fire Alarm Control Panel PFC-8500 Fire Alarm Control Panel PFC-9000 Addressable Fire Alarm Panel SOM-4 Supervised Output Module MOM-4 Monitored Output Module PSN Series Power Supplies SMD 10-3A Potter/AMSECO Synchronization Module PFC-6030, PFC-6075, PFC-6075R, PFC-6200, PFCNAC Circuits 6800, PFC-6500(R), P100-P400R I/O Circuits Addressable Fire Panel PFC-6006 Sprinkler Monitoring Panel Column Amps per Load A 1 B 1.5 C 2 D 3 D 3 A 1 E 0.5 2. Go to the page that correlates to the Manufacturer of the horn, strobe, chime, bell, or device that will be connected to the Panel, and find the specific row for the device: Manufacturer Potter/ AMSECO Gentex Cooper/Wheelock System Sensor Page 4 5 6-7 8 3. Use the column from Step 1, and the device row from Step 2, find the corresponding number of devices per circuit that can be connected. 3 NAC COMPATIBILITY • 5403592 • REV E • 01/14 Potter/AMSECO Model Type H-1224 HP-25T SL-1224 SL-1224-WP CSL-1224W * SL-24H SL-24H-WP SL24C-3075110 SL24C-177 CSL-24C * SH-1224 SH-1224-WP CSH-1224-W * SH-24H SH-24H-WP SH24C-3075110 SH24C-177 CM24C SCM24-3075110 SB24-1530 SB-75110 SC24-30750110 SLB24-75 CSLB24 * SHB24-75 CSHB24 * MBA Bell SMD10-3A Horn Horn Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Chime Strobe/Chime Strobe Strobe Strobe Strobe Strobe Strobe Strobe Bell Sync Module A B C D Number of Devices. Refer to the Panel Key. 16 21 31 55 74 111 26 33 49 11 15 22 11 15 22 9 13 19 9 13 19 12 17 25 4 5 7 9 12 18 19 26 39 9 12 18 9 12 18 7 9 13 7 9 13 5 7 10 3 4 6 36 48 72 10 13 19 23 31 46 10 14 21 23 31 46 9 12 18 9 12 18 7 10 15 7 10 15 24 32 48 1 1 1 10 36 16 7 7 6 6 8 2 6 12 6 6 4 4 3 2 24 6 15 6 15 6 6 4 4 16 1 * Not for evacuation 4 E 5 18 8 3 3 3 3 4 1 3 6 3 3 2 2 1 1 12 3 7 3 7 3 3 2 2 8 1 NAC COMPATIBILITY • 5403592 • REV E • 01/14 Gentex Model Type GES3-24 GEC3-24 GCS GCC GCS Colored Strobe * GCC Colored Combo * GEC GEC Colored Lens * GES GES Colored Lens * GEH GX93 WGES24 WGEC24 WGES24 Colored Lens * WGEC24 Colored Lens * S-24W HS-24W CS-24R CHS-24R CCS-24AR CCHS-24AR* EH-24R MHT-1224R WGES24-75WR WGEC24-75WR CS-24WAR CHS-24AR Strobe Strobe/Horn Strobe Strobe/Horn Strobe Strobe/Horn Strobe/Horn Strobe/Horn Strobe Strobe Horn Horn Strobe Strobe/Horn Strobe Strobe/Horn Strobe Strobe/Horn Strobe Strobe/Horn Strobe Strobe/Horn Horn Horn Strobe Strobe/Horn Strobe Strobe/Horn A B 12 9 8 6 8 6 9 9 12 12 35 55 5 4 5 4 12 9 8 6 8 6 35 55 5 4 5 4 Number of Devices. Refer to the Panel Key. 19 25 37 14 18 27 12 16 24 10 13 19 12 16 24 10 13 19 14 18 27 14 18 27 19 25 37 19 25 37 53 71 106 83 111 166 8 11 16 7 9 13 8 11 16 7 9 13 19 25 37 14 18 27 12 16 24 10 13 19 12 16 24 10 13 19 53 71 106 83 111 116 8 11 16 7 9 13 8 11 16 7 9 13 * Not for evacuation 5 C D E 6 4 4 3 4 3 4 4 6 6 17 27 2 2 2 2 6 4 4 3 4 3 17 27 2 2 2 2 NAC COMPATIBILITY • 5403592 • REV E • 01/14 Cooper/Wheelock Model Type HN HNC HS-24 NH-12/24 AH-24 AH-24WP MIZ-24S AMT-12/24 HS HSC AS-24MCW AS-24MCWH AS-241575W AS-24MCC AS-24MCCH ASWP-2475W HS4-241575W HS4-24MCW HS4-24MCC HS4-24MCWH NS-241575W NS-24MCW NS-24MCC NS-24MCCH ST STC RSS-241575W RSS-24MCW RSS-24MCC RSS-24MCWH RSS-24MCCH RSSP-241575W RSSP-24MCW RSSP-24MCWH RSSWP-2475W AMT-241575W AMT-24MCW AMT4-241575W-NYC MT-241575W Horn Horn Horn Horn Horn Horn Horn Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn A 20 20 36 22 47 47 38 24 15 15 14 2 10 13 2 6 6 10 10 2 10 14 14 12 17 16 10 16 15 3 3 10 16 3 6 8 12 8 8 6 B C D Number of Devices. Refer to the Panel Key. 31 42 62 31 42 62 55 74 110 34 45 67 71 95 142 71 95 142 57 76 114 36 48 72 23 30 45 23 30 45 22 29 43 4 5 7 15 20 30 20 27 40 4 5 7 10 13 19 9 12 18 16 21 31 16 21 31 4 6 8 15 20 30 22 30 44 18 28 38 4 6 8 26 35 52 24 32 48 16 22 32 25 33 49 23 30 45 5 6 9 5 6 9 16 22 32 25 33 49 5 6 9 10 14 20 13 18 26 18 25 36 12 17 24 13 17 25 E 10 10 18 11 23 23 19 12 7 7 7 1 5 6 1 3 3 5 5 1 5 7 7 6 8 8 5 8 7 1 1 5 8 1 3 4 6 4 4 NAC COMPATIBILITY • 5403592 • REV E • 01/14 Cooper/Wheelock (continued) Model Type A B C D E MT-24MCW MTWP-2475W AMT-12/24-NYC MT-12/24 MT4-12/24 Strobe/Horn Strobe/Horn Horn Horn Horn 11 6 24 40 25 17 10 36 62 38 23 13 48 80 51 34 19 72 121 76 5 3 12 20 12 7 NAC COMPATIBILITY • 5403592 • REV E • 01/14 System Sensor Model Type HR/HW HRK/HWK MH CHR/CHW SR/SW SRH/SWH SRK/SWK SRH/SHW SRHK/SWHK SCR/SCW SCRH/SCWH SCRHK/SCWHK P2R/P2W P2RH/P2WH P2RK/P2WK P2RHK/P2WHK PC2R/PC2W PC2RK/PC2WK PC2RH/PC2WH PC2RHK/PC2WHK P4R/P4W P4RH/P4WH PC4R/PC4W PC4RH CHSR/CHSW MDL3R/MDL3W Horn Horn Horn Chime Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn Strobe/Horn* Strobe/Horn* Strobe/Horn* Strobe/Horn* Strobe/Chime Sync Module A B C D Number of Devices. Refer to the Panel Key. 28 38 57 28 38 57 107 142 214 44 58 88 22 30 45 6 8 13 22 30 45 6 8 13 6 8 13 22 30 45 6 8 13 6 8 13 22 30 45 6 8 13 22 30 45 6 8 13 22 30 45 22 30 45 6 8 13 6 8 13 22 30 45 6 8 13 6 8 13 6 8 13 23 31 46 1 1 1 19 19 71 29 15 4 15 4 4 15 4 4 15 4 15 4 15 15 4 4 15 4 4 4 15 1 * Not for evacuation 8 E 9 9 35 14 7 2 7 2 2 7 2 2 7 2 7 2 7 7 2 2 7 2 2 2 7 1