Functional Devices, Inc. RIBTW2401B RIB ® Lonworks Enclosed Relay 20Amp SPDT with 24 Vac/dc or 120 Vac Power Input Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast N/O @ 120/277 Vac 10 Amp Ballast N/C @ 120/277 Vac 10 Amp Tungsten N/O @ 120 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c MADE IN USA Functional Devices, Inc. A600C 2005 # Relays & Contact Type: Expected Relay Life: Operating Temperature: Operate Time: Green LED: Red LED: Yellow LED: Dimensions: Wires: Approvals: One (1) SPDT Continuous Duty Coil 10 million cycles minimum mechanical -30 to 140° F 18mS Network Status Relay Status Service Status 4.00” x 4.00” x 1.80” with .50” NPT Nipple 16”, 600V Rated FCC, LonMark® UL Listed, UL916, C-UL Canada Housing Rating: Plenum, NEMA 1 Gold Flash: No Override Switch: No Transceiver Type: FTT-10A with blocking capacitors for compatibility with link power channel Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: XIF, APB, and NEI Notes: Functional Devices, Inc. Office: (765) 883-5538 310 South Union Street Sales: (800) 888-5538 Russiaville, IN 46979 Fax: (765) 883-7505 www.functionaldevices.com Email: sales@functionaldevices.com Manufacturing quality products in the United States of America since 1969 LON LON Class 2 Dry Contact Digital Input 24 Vac/dc Comm Input Power: 111 mA @ 24 Vac 96 mA @ 120 Vac 81 mA @ 24 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz NODE OBJECT NV1 nvi Request Wht/Yel Neutral Wht/Blk 120 Vac CLOSED LOOP ACTUATOR nvi Value Yel Comm Org N/O NV2 nvo Status DESCRIPTION NV1 Blu N/C NV2 nvo Value Fb nci Default nci Max Receive T Command to open/close relay Command status of relay Default state of relay on/off Communication timer Invert status of Digital-In Max time between updates Min time between updates SNVT NAME SNVT TYPE nvi Value nvo Fb Value nci Default nci Max Receive T nci Invert nci Max Send T nci Min Send T SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm OPEN LOOP SENSOR OBJECT NV1 nci Invert nci Max Send T nci Min Send T nvo Value The relay will go to the default state when the communication timer times out. Setting the timer value to zero will cause the communication to never time out. Functional Devices, Inc. RIBTW2402B RIB ® Functional Devices, Inc. Office: (765) 883-5538 310 South Union Street Sales: (800) 888-5538 Russiaville, IN 46979 Fax: (765) 883-7505 www.functionaldevices.com Email: sales@functionaldevices.com Manufacturing quality products in the United States of America since 1969 Lonworks Enclosed Relay 20Amp SPDT with 24 Vac/dc or 208-277 Vac Power Input Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast N/O @ 120/277 Vac 10 Amp Ballast N/C @ 120/277 Vac 10 Amp Tungsten N/O @ 120 Vac 1110 VA Pilot Duty @ 277 Vac 770 VA Pilot Duty @ 120 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c c MADE IN USA Functional Devices, Inc. A600C 2005 # Relays & Contact Type: Expected Relay Life: Operating Temperature: Operate Time: Green LED: Red LED: Yellow LED: Dimensions: Wires: Approvals: One (1) SPDT Continuous Duty Coil 10 million cycles minimum mechanical -30 to 140° F 18mS Network Status Relay Status Service Status 4.00” x 4.00” x 1.80” with .50” NPT Nipple 16”, 600V Rated FCC, LonMark® UL Listed, UL916, C-UL Canada Housing Rating: Plenum, NEMA 1 Gold Flash: No Override Switch: No Transceiver Type: FTT-10A with blocking capacitors for compatibility with link power channel Functional Blocks: 0000 Node Object 0004 Closed Loop Actuator Object 0001 Open Loop Sensor Object Downloadable Files: XIF, APB, and NEI Notes: LON LON 24 Vac/dc Class 2 Dry Contact Digital Input Comm Input Power: 111 mA @ 24 Vac 105 mA @ 208-277 Vac 81 mA @ 24 Vdc Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz NODE OBJECT NV1 nvi Request Wht/Yel Neutral Wht/Brn 208-277 Vac CLOSED LOOP ACTUATOR nvi Value Yel Comm Org N/O NV2 nvo Status DESCRIPTION NV1 Blu N/C NV2 nvo Value Fb nci Default nci Max Receive T Command to open/close relay Command status of relay Default state of relay on/off Communication timer Invert status of Digital-In Max time between updates Min time between updates SNVT NAME SNVT TYPE nvi Value nvo Fb Value nci Default nci Max Receive T nci Invert nci Max Send T nci Min Send T SNVT_switch SNVT_switch SNVT_switch SNVT_elapsed_tm SNVT_lev_disc SNVT_elapsed_tm SNVT_elapsed_tm OPEN LOOP SENSOR OBJECT NV1 nci Invert nci Max Send T nci Min Send T nvo Value The relay will go to the default state when the communication timer times out. Setting the timer value to zero will cause the communication to never time out.