Table of Contents Section 18 IEC Contactors and Starters Contactors D-Line 18-2 F-Line 18-3 K-Line 18-23 D- and F-Line Accessories 18-6 K-Line Accessories 18-26 D-Line Contactors (p. 18-2) New! F-Line Contactors (p. 18-3) U-Line Controllers 18-27 GV2, GV3, GV7 Manual Motor Protectors 18-33 Enclosed D-Line 18-20 GV Accessories 18-34 LS1D Fuse Block 18-36 LUTM Motor Controllers 18-31 Overload Relays D-Line 18-2 F-Line GV7 Manual Motor Starters and Protectors (p. 18-35) 18-3 D-Line and F-Line Accessories 18-14 K-Line 18-23 K-Line Accessories 18-26 Soft Start Module ATS01 18-32 Replacement Parts D-Line Coils 18-17 to 18-18 F-Line Coils 18-17, 18-19 F-Line Contact Tips, etc. 18-11 Wiring Systems GV-Line Bus Bars 18-37 D-Line Quickfit 18-38 AK5 18-39 Dimensions GV3P (p.18-33) LUB•2 (p. 18-28) 18-40 GV2P21 (p.18-33) See our website, www.us.schneider-electric.com, for UL 508A short circuit ratings (SCCR). © 2007 Schneider Electric All Rights Reserved 18-1 18 New! IEC CONTACTORS AND STARTERS Motor Starters and Protectors Contactors & Overload Relays TeSys™ D-Line Non-reversing Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.1: 3- or 4-Pole Screw Terminal Connections Maximum Current Utilization Categories Maximum Horsepower Ratings Single Phase LC1D09 18 IEC CONTACTORS AND STARTERS LC1D093 Three Phase Catalog Number a $ Price D-Line Overload Relays — Ambient Compensated, Bi-Metallic Direct Mount Current Setting Range Amperes LRD22 Instantaneous Auxiliary Contacts Inductive Resistive AC3 AC1 N.O. N.C. N.O. N.C. 115 V 230 V 200 V 230 V 460 V 575 V AC Coils DC Coils Amperes Amperes hp hp hp hp hp hp 94.00 119.00 0.5 1 2 2 5 7.5 9 3 LC1D09 cd 0 94.00 119.00 — — — — — — — 4 LC1DT20 c 20 1 1 — — — — — — — 2 2 LC1D098 c 94.00 119.00 119.00 149.00 1 2 3 3 7.5 10 12 3 LC1D12 cd 0 — — — — — — — 4 LC1DT25 c 25 1 1 119.00 149.00 — — — — — — — 2 2 LC1D128 c 119.00 149.00 136.00 160.00 1 3 5 5 10 15 18 3 LC1D18 cd 0 — — — — — — — 4 LC1DT32 c 32 1 1 149.00 183.00 — — — — — — — 2 2 LC1D188 c 149.00 183.00 151.00 181.00 2 3 7.5 7.5 15 20 25 3 LC1D25 cd 0 — — — — — — — 4 LC1DT40 c 40 1 1 193.00 240.00 — — — — — — — 2 2 LC1D258 c 193.00 240.00 172.00 213.00 2 5 10 10 20 30 32 50 3 0 1 1 LC1D32 cd 3 5 10 10 30 30 40 3 1 1 LC1D40 296.00 275.00 0 — — — — — — — 60 4 LC1D40004 b 296.00 353.00 0 0 296.00 353.00 — — — — — — — 2 2 LC1D40008 b 3 7.5 15 15 40 40 50 3 LC1D50 234.00 291.00 0 1 1 5 10 20 20 50 50 65 3 LC1D65 322.00 379.00 80 — — — — — — — 4 0 LC1D65004 b 446.00 503.00 0 0 446.00 503.00 — — — — — — — 2 2 LC1D65008 b 7.5 15 25 30 60 60 80 3 1 1 LC1D80 363.00 420.00 0 — — — — — — — 125 4 LC1D80004 b 489.00 524.00 0 0 489.00 524.00 — — — — — — — 2 2 LC1D80008 b — — 30 40 75 100 115 3 LC1D115 479.00 479.00 1 1 — — 40 50 100 125 150 200 3 0 LC1D150 696.00 696.00 — — — — — — — 4 0 0 LC1D115004 630.00 630.00 a Complete catalog number with coil voltage code from table on page 18-3; example, LC1D09G7. b For DC version of these devices replace the 'C' with 'P' (ex LC1D40004**) becomes LP1D40004**). c On LC1D09 - LC1D32 and LC1DT20 through LC1DT40, for ring tongue versions add '6' to the catalog number prior to adding the voltage code (ex, LC1D09G7 becomes LC1D096G7). No Price adder for this modification. d On LC1D09 - LC1D32, for spring terminals versions add '3' to the catalog number prior to adding the voltage code (ex., LC1D09G7 becomes LC1D093G7). No price adder for this modification. Table 18.2: LC1D115 No of Poles 0.10–0.16 0.16–0.25 0.25–0.40 0.40–0.63 0.63–1 1–1.6 1.6–2.5 2.5–4 4–6 5.5–8 7–10 9–13 12–18 16–24 17–25 23–32 23–28 25–32 30–38 17–25 23–32 30–40 37–50 48–65 55–70 63–80 80–104 80–104 95–120 110–140 Table 18.3: Class 10 with Single Phase Sensitivity LRD01 LRD02 LRD03 LRD04 LRD05 LRD06 LRD07 LRD08 LRD10 LRD12 LRD14 LRD16 LRD21 LRD22 — LRD32 — — LRD35 LRD3322 LRD3353 LRD3355 LRD3357 LRD3359 LRD3361 LRD3363 LRD3365 LRD4365 LRD4367 LRD4369 For Direct Mounting to LC1 ttt D09–D32 D09–D32 D09–D32 D12–D32 D18–D32 D25–D32 D25–D32 D25–D32 D25–D32 D25–D32 D32 D40–D80 D40–D80 D40–D80 D50–D80 D50–D80 D65–D80 D65–D80 D80 D115–D150 D115–D150 D150 Class 10 without Single Phase Sensitivity LR3D01 LR3D02 LR3D03 LR3D04 LR3D05 LR3D06 LR3D07 LR3D08 LR3D10 LR3D12 LR3D14 LR3D16 LR3D021 LR3D22 — LR3D32 — — LR3D35 LR3D3322 LR3D3353 LR3D3355 LR3D3357 LR3D3359 LR3D3361 LR3D3363 — — — — Class 20 with Single Phase Sensitivity — — — — — — — LRD1508 LRD1510 LRD1512 LRD1514 LRD1516 LRD1521 — — LRD1530 LRD1532 — LR2D3522 LR2D3553 LR2D3555 LR2D3557 LR2D3559 LR2D3561 LR2D3563 — — — — Class 20 without Single Phase Sensitivity — — — — — — — LR3D1508A1 LR3D1510A1 LR3D1512A1 LR3D1514A1 LR3D1516A1 LR3D1521A1 — LR3D1522A1 — LR3D1530A1 LR3D1532A1 — LR3D3522 LR3D3553 LR3D3555 LR3D3557 LR3D3559 LR3D3561 LR3D3563 — — — — $ Price 60.00 62.00 73.00 107.00 127.00 362.00 D-Line Overload Relays — Solid State Current Setting Range Amperes 60–100 90–150 For Direct Mounting Beneath Contractor LC1 D115–D150 D115–D150 Class 10 Class 20 $ Price LR9D5367 LR9D5369 LR9D5567 LR9D5569 298.00 298.00 D-Line contactor accessories . . . . . . . . . . . . . . . . . . . . . . pages 18-6 to 18-9 D-Line overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 D-Line replacement coils . . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 18-2 I12 Discount Schedule Modified 4/17/09 © 2007 Schneider Electric All Rights Reserved www.us.schneider-electric.com Contactors & Overload Relays TeSys™ F-Line Non-reversing Refer to Catalog 8502CT9901 FOR CURRENT INFORMATION 2-, 3-, and 4-Pole Contactors 575 V 600 V Catalog Number a Maximum Current 200 V 208 V 220 V 240 V 460 V 480 V HP HP HP HP A A 30 40 75 100 115 200 40 50 100 125 150 250 50 60 125 150 185 275 225 315 AC-3 Number of Poles AC-1 3 4 3 4 3 4 3 4 3 4 3 4 2 3 4 2 3 4 2 3 4 3 4 3 LC1F115 Current Rated 60 75 150 175 265 350 75 100 200 250 330 400 100 125 250 300 400 500 150 200 400 500 500 700 250 300 600 800 630 1000 780 1600 — 450 900 800 1000 Current Rated Table 18.5: 800 $ Price Panel Mount with Screws LC1F115 LC1F1154 LC1F150 LC1F1504 LC1F185 LC1F1854 LC1F225 LC1F2254 LC1F265 LC1F2654 LC1F330 LC1F3304 LC1F4002 LC1F400 LC1F4004 LC1F5002 LC1F500 LC1F5004 LC1F6302 LC1F630 LC1F6304 LC1F780 LC1F7804 LC1F800 479.00 630.00 696.00 825.00 938.00 1439.00 1167.00 1935.00 1179.00 1646.00 1621.00 1846.00 1521.00 1874.00 2133.00 4324.00 4970.00 5617.00 5917.00 6872.00 7582.00 7788.00 9940.00 6676.00 3-Phase Overload Relays — Solid State Separate Mount b For Direct Mounting to Contactor Class 10 Trip c Class 20 c $ Price LC1●●●●/CR1F●●●● Catalog Number Catalog Number 30–50 F115–F185 LR9F5357 LR9F5557 298.00 48–80 F115–F185 LR9F5363 LR9F5563 298.00 60–100 F115–F185 LR9F5367 LR9F5567 298.00 90–150 F115–F185 LR9F5369 LR9F5569 298.00 132–220 F185 d –F265 LR9F5371 LR9F5571 298.00 200–330 F265–F500 LR9F7375b LR9F7575b 333.00 300–500 F265–F500 LR9F7379b LR9F7579b 737.00 380–630 F400–F630 LR9F7381b LR9F7581b 905.00 Complete part number by adding coil voltage code from table below. For example: LC1F115G7. All contactors (except F780) include 1 N.O. coil interlock contact. When mounting overload relays LR9F5●57 to LR9F5●71 directly beneath the contactor, supporting the relays with a mounting plate is recommended. With overload relays LR9F7●75 to LR9F7●81, use of a support mounting plate is mandatory. IEC standard 60947-4 specifies the following trip times when the overload relay senses 7.2 times the setting current: Class 10 — between 4 and 10 seconds Class 20 — between 6 and 20 seconds Interconnection kit LA7F407 is required to mount an LR9F●71 to an LC1F185. Current Setting Range Amps a b c d Table 18.6: Coil Voltage Codes h Contactor Hz D09–D150 50/60 60 50 50 60 40–400 40–400 LC1D40–LC1D150 only F115, F150, and F185 F265, and F330 F400— F780 24 V B7 B6 B5 B5 B6 B7 — 48 V E7 E6 E5 E5 E6 E7 E7 110 V F7 F6 F5 F5 F6 F7 F7 120 V AC G7 G6 — — G6 G7 G7 DC — — — — 125 V 208 V 220 V 240 V 250 V 440 V 480 V 600 V — — — — — — — LE7 L6 — — L6 L7 L7 M7 M6 M5 e M5 M6 M7 M7 U7 U6 U5 U5 U6 U7 U7 — — — — — — — — — — — — — — T7 e T6 — — Q5 S7i N7 X7 ef X6 f — — SC X7 X7 g — — — — UL UD UD UD — RD RD RD — — — — — — — — D09–D32 Low Consumption — BL EL FL — — ML D09–D150 — BD ED FD GD — MD F115-F330 — BD ED FD GD — MD F400–F780 — — ED FD GD — MD e Not available for LC1D40 - LC1D150 f Not available for LC1D115 or LC1D150 g Not available for LC1F780 The 600 V coils for the LC1F400 - LC1F630 do not include an auxiliary contact for holding circuits. h For additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901. i For use with F265—F330 only. Table 18.7: Volts AC/DC 50/60 HZ Coil Voltage Codes for AC and DC Voltages for F800 (includes built-in surge supressor) 24 — 48 — 110 FW 120 FW 127 FW 208 — 220 MW 240 MW 277 — 380 QW 415 QW 440 QW 480 — 575 — 600 — 660 — F-Line contactor accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-9 F-Line overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . .page 18-14 F-Line replacement coils and parts . . . . . . . . . . . pages 18-11, 18-17, 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-49 © 2007 Schneider Electric All Rights Reserved I12 Discount Schedule Modified 4/16/09 18-3 IEC CONTACTORS AND STARTERS Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 18 Table 18.4: Contactors TeSys™ D-Line 3- and 4-Pole Reversing, AC or DC Operating Coil Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Each 3-pole device is pre-wired with line and load side power wiring for reversing applications. Each 4-pole device is pre-wired with load side power wiring Table 18.8: 3-Pole & 4-Pole Mechanically Interlocked Contactors Maximum Horsepower Ratings Maximum Current Built In Auxiliary $ Price No. of N.O. Catalog Contacts Inductive Resistive Power Number (per contactor) AC DC AC3 AC1 Poles ab Control Control 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp Amperes Amperes N.O. N.C. 0.5 1 2 2 5 7.5 9 3 1 1 LC2D09c 234.00 317.00 20 — — — — — — — 4 1 1 LC2DT20 234.00 317.00 1 2 3 3 7.5 10 12 3 1 1 LC2D12c 317.00 368.00 25 — — — — — — — 4 1 1 LC2DT25 317.00 368.00 1 3 5 5 10 15 18 35 3 1 1 LC2D18c 344.00 400.00 — — — — — — — 32 4 1 1 LC2DT32 419.00 443.00 2 3 7.5 7.5 15 20 25 3 1 1 LC2D25c 374.00 436.00 40 — — — — — — — 4 1 1 LC2DT40 456.00 477.00 2 5 10 10 20 30 32 50 3 1 1 LC2D32c 415.00 503.00 3 5 10 10 30 30 40 3 1 1 d — 60 — — — — — — — 4 — — d — 3 7.5 15 15 40 40 50 70 3 1 1 d — 5 10 20 20 50 50 65 3 1 1 d — 80 — — — — — — — 4 — — d — 7.5 15 30 30 60 60 80 3 1 1 d — 125 — — — — — — — 4 — — d — — — 30 40 75 100 115 3 1 1 LC2D115 1165.00 1165.00 200 — — — — — — — 4 — — LC2D115004 1391.00 1391.00 — — 40 50 100 125 150 200 3 1 1 LC2D150e 1598.00 1598.00 a Use voltage codes from the ""Voltage Codes"" table below to complete the catalog number. For example: LC2D09G7 b Includes mechanical interlock without electrical contacts. Installer to complete wiring for electronically interlocking contactor operating coils by utilizing a N.C. auxiliary contact integrated in the contactor or optional LADN or LAD8N auxiliary contact block. c For LC2D09–LC2D32, electrical interlock can be included by adding a ""V"" to the end of the catalog number (ex: LC2DO9B7V). List price adder: $5.00. d For these items, order two non-reversing contactors and one mechanical interlock separately. See page 18-2 and 18-12 for selection. e Includes mechanical interlock (Type LA9D11502) with pre-wired electrical contacts for interlocking contactor operating coils. Single Phase LC2D09 18 IEC CONTACTORS AND STARTERS Table 18.9: Three Phase Coil Voltage Codes i Contactor Hz D09–D150 50/60 50 60 50 Hz F115, F150, F185 60 Hz F265, F330 40–400 Hz F400–F780 40–400 Hz LC1D40–LC1D150 24 V B7 B5 B6 B5 B6 B7 — 48 V E7 E5 E6 E5 E6 E7 E7 110 V 120 V 125 V 208 V 220 V 240 V 250 V 440 V 480 V 600 V G7 — G6 — G6 G7 F7 AC — — — — — — — DC LE7 — L6 — L6 L7 L7 M7 M5 f M6 M5 M6 M7 M7 U7 U5 U6 U5 U6 U7 U7 — — — — — — — — — — — — — — T7 f — T6 — Q5 S7 j N7 X7 f — X6 gf — SC X7 X7 h — — — — — — — — F7 F5 F6 F5 F6 F7 F7 D09–D32 — BL EL FL — — — ML — UL — Low Consumption D09–D150 — BD ED FD — GD — MD — UD RD F115–F330 — BD ED FD — GD — MD — UD RD F400–F780 — — ED FD — GD — MD — UD RD f Not available for LC1D40 - LC1D150. g Not available for LC1D115 or LC1D150. h Not available for LC1F780. The 600 V coils for the LC1F400 - LC1F630 do not include an auxiliary contact for holding circuits. i For additional voltage codes refer to the IEC Contactor and Starter Catalog 8502CT9901. j For use with F265—F330 only. Table 18.10: Volts AC/DC 50/60 Hz Coil Voltage Codes for AC and DC Coil Voltages for F800 (includes built-in surge suppressor) 24 — 48 — 110 FW 120 FW 127 FW 208 — 220 MW 240 MW 277 — 380 QW 415 QW 440 QW 480 — 575 — 600 — 660 — D-Line contactor accessories . . . . . . . . . . . . . . . . . . . . . . pages 18-6 to 18-9 D-Line overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 D-Line replacement coils . . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 18-4 I12 Discount Schedule Modified 4/16/09 © 2007 Schneider Electric All Rights Reserved Contactors TeSys™ F-Line 3-Pole Reversing, AC or DC Operating Coil Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION HOW TO ORDER: Components are available for customer assembly of F-line reversing contactors. For example, the following components must be ordered to build a 75 hp @ 460 V reversing contactor with a 120 V/60 Hz coil: Table 18.11: Catalog Number LC1F115G6 DZ2FF1 LADN11 LA9FF976 LA9FF970 3-Pole Contactors Maximum Horsepower Ratings Three Phase Maximum Current Holding Circuit Contact Built Into Coil Catalog $ Price Numbera 230 V 460 V 575 V N.O. N.C. hp hp hp 40 75 100 115 200 1 0 LC1F115 479.00 50 100 125 150 250 1 0 LC1F150 696.00 60 125 150 185 275 1 0 LC1F185 938.00 75 150 200 265 350 1 0 LC1F265 1179.00 100 200 250 330 400 1 0 LC1F330 1621.00 125 250 300 400 500 1 0 LC1F400 1874.00 200 400 500 500 700 1 0 LC1F500 4970.00 300 600 800 630 1000 1 0 LC1F630 6872.00 Current rated 780 1600 0 0 LC1F780 7788.00 — 450 800 900 800 1000 0 0 LC1F800 6676.00 a Use coil voltage codes from the “Voltage Codes” table on page 18-4 to complete the contactor catalog number. Inductive AC3 Amperes 200 V hp 30 40 50 60 75 100 150 250 Table 18.13: Resistive AC1 Amperes Auxiliary contact (electrical interlocking) - 2 must be purchased For use with Number of Contacts Maximum Number of Blocks Per Contactor 1 1 2 2 4 2 LC1F to be ordered separately b 1 — 1 2 2 1 4 — 3 2 — 1 1 2 3 — 4 1 2b Catalog Number LADN10 LADN01 LADN11 LADN20 LADN22 LADN13 LADN40 LADN04 LADN31 LADC22 $ Price 13.10 13.10 20.70 20.70 41.50 41.50 41.50 41.50 41.50 41.50 including 1 N.O. + 1 N.C. make-before-break Table 18.14: Accessories—For the assembly of three-pole reversing contactors (horizontal mounting) With 2 Identical Contactors c c Contact Arrangement Set Of Power Connections Catalog Number LC1F115 LA9FF976 LC1F150 LA9F15076 LC1F185 LA9FG976 LC1F265 LA9FH976 LC1F330 LA9FJ976 LC1F400 LA9FJ976 LC1F500 LA9FK976 LC1F630, F800 LA9FL976 For two contactors of different size, refer to pages 18-13. $ Price 106.00 96.00 113.00 151.00 225.00 198.00 306.00 568.00 Horizontal Mounting Mechanical Interlock Kit Catalog Number LA9FF970 LA9FF970 LA9FG970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FL970 $ Price 53.00 53.00 53.00 76.00 76.00 76.00 76.00 76.00 F-Line contactor accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-9 F-Line overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 F-Line replacement coils and parts . . . . . . . . . . . pages 18-11, 18-17, 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-42 © 2007 Schneider Electric All Rights Reserved I12 Discount Schedule Modified 4/16/09 18-5 IEC CONTACTORS AND STARTERS Table 18.12: Description Contactors Lugs (page 18-15) Auxiliary contacts Power connections Mechanical interlock 18 LC1F265 Quantity 2 6 2 1 1 Contactor Accessories TeSys™ D-Line & F-Line Auxiliary Contacts, Time Delay, Mechanical Latch Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.15: Standard, instantaneous auxiliary contact blocks Snap-On Mounting Composition Number of Contacts To front of LP●D40–D80, LC● DT20–DT40 (4P), LC●D09–D150a or To right side of LC ● F 4a 2 Front Mounted Auxiliary Blocks (shown on D-LIne contactor) To front of LP●D40–D80, LC ●DT20–DT40 (4P), LC● D25 to D150 or To left side of LC●F 1 To side of LC●D09 to D150 only (not for use on F-LIne) 2 18 a b c d e 1 0 0 1 Catalog Number a $ Price LADN22 b LADN13 b LADN40 b LADN04 b LADN31 b LADC22 bc LADN11 b LADN20 b LADN02b 41.50 41.50 41.50 41.50 41.50 41.50 20.70 20.70 20.70 LADN10 d LADN01 d 13.10 13.10 IEC CONTACTORS AND STARTERS Instantaneous blocks with dust-tight auxiliary contacts (IP54) NEMA 12 Standard Contacts Dusttight Contacts Snap-On Mounting N.O. — 2 1 To front of LP● D40–D80, LC ● DT20–DT40 (4P), LC ● D09 to D80 or To right side of — LC ●F f Device supplied with 4 ground terminal points. Table 18.17: N.C. — — 1 N.O. 2 2 2 N.C. — — — — 2 — Catalog Number $ Price LA1DX20 LA1DZ40 LA1DZ31 65.00 82.00 82.00 LA1DY20f 77.00 Pneumatic time delay contact blocks Time Delay Contacts Snap-On Mounting N.O. Range of Time Delay Type N.C. Catalog Number h $ Price 0.1 to 3 sg LADT0 131.00 0.1 to 30 s LADT2 131.00 10 to 180 s LADT4 131.00 1 to 30 si LADS2 131.00 0.1 to 3 sg LADR0 131.00 On de-energization 0.1 to 30 s 1 1 LADR2 131.00 (off-delay) 10 to 180 s LADR4 131.00 Scale range is expanded between 0.1 and 0.6 seconds on the dial for more accurate settings at the lower end of the range. For spring terminal versions of these blocks, add a “3” to the end of the catalog number. For example, LADT023. With switching time of 40 ms ± 15 ms between the opening of the N.C. contact to the closing of the N.O. contact. To front of LP● D40–D80, LC● DT20–DT40 (4P), LC ● D09 to D150 or To right side of LC● F h i N.C. 2 3 0 4 1 2c 1 0 2 1 1 LAD8N11 e 20.70 2 0 LAD8N20 e 20.70 For low consumption coils, only one front-mounted two-contact block allowed. No side-mounted contact blocks allowed. For spring terminal versions of these blocks, add a “3” to the end of the catalog number. For example, LADN223. Including 1 N.O. + 1 N.C. make before break overlapping contacts. This block cannot be added to the LC1D 09 to D32 contactors; a maximum of 2 blocks can be mounted on the LC1/LP1 D40 to D80 contactors only. 1 block may be added to the left side of the LC1D 09 to D32, AC coils only; 1 block may be added to each side of the LC1D 40 to D80 contactors, AC coils only. Cannot be installed on D-Line contactors with DC coils. Table 18.16: g N.O. 2 1 4 0 3 2c 1 2 0 Table 18.18: 1 On energization (on delay) 1 Mechanical latch blocks with manual or electrical unlatch (D-Line only) Front snap-on mounting onto Catalog number to be completed by the code corresponding to the coil voltage Application $ Price For silent operation and energy LA6DK10jk conservation For silent operation and energy LC1 D80 to D150 LP1 D80 LA6DK20jk conservation j Does not include internal coil clearing contact. k Complete catalog number by adding coil voltage code. For example: LA6DK10F. LC●/LP ●D09 to D65 Table 18.19: 77.00 77.00 Coil Voltage Codes for LA6DK mechanical latch blocks Volts 12 24 32/36 42/48 60/72 100 110/ 127 200/ 208 220/ 240 380/ 415 440/ 480 500/ 600 AC or DC J B C E EN K F L M Q R S D-Line contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-2, 18-4 D-Line overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 D-Line replacement coils . . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 18-6 I12 Discount Schedule © 2007 Schneider Electric All Rights Reserved Contactor Accessories TeSys™ D-Line Coil Suppressors, Cabling Accessories Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION RC Coil Suppressor • • • Limitation of transient voltage to 300% of nominal voltage maximum Oscillating frequency limited to 400 Hz maximum Slight increase in drop-out time (1.2 to 2 times normal) Table 18.20: LA4DA1U Resistor/capacitor circuit (RC) for reduction of “electrical noise” in AC contactor coils Installed by Mounting on Operating voltage 50/60 Hz 24–28 V 50–127 V 110–240 V 24–48 V LC D12 and D25 (4P) 50–127 V Pre-TeSys Contactors 110–240 V 24–48 V LC●D40 to D150 (3 or 4P) 50–127 V LC●D40 to D115 (4P) 110–240 V 380–415 V LC1D09 to LC1D32 (3P) LC●DT20 to DT40 (4P), Snapping into cavity on right side without toolsb · Snap-on mounting and connection without tools to the contactor coil terminals Screw connection to the contactor coil terminals Catalog Number LAD4RCE LAD4RCG LAD4RCU LA4DA1E LA4DA1G LA4DA1U LA4DA2E LA4DA2G LA4DA2U LA4DA2N $ Price 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 Varistor Coil Suppressor Table 18.21: Varistor (peak limiting) for reduction of “electrical noise” in AC or DC contactor coils Installed by Mounting on Operating voltage 50/60 Hz 24–48 V LC●D09 to D32a Snapping into cavity on right side without toolsb 50–127 V TeSys contactors 110–250 V 24– 48 V Snap-on mounting and connection without tools to the LC●D09 to D32 50–127 V contactor coil terminals Pre-TeSys contactors 110–250 V 24–48 Vac LC ●D40 to D115 (3P or 4P) Screw connection to the contactor coil terminals 50–127 Vac LC●D12, D25 (4P) 110–250 Vac 24–48 Vdc Screw connection to the contactor coil terminals LC●D40 to D115 (3P or 4P) 50–127 Vdc 110–250 Vdc a For DC coils 3-pole contactors are fitted with built-in surge suppression as standard. Catalog Number LAD4VE LAD4VG LAD4VU LA4DE1E LA4DE1G LA4DE1U LA4DE2E LA4DE2G LA4DE2U LA4DE3E LA4DE3G LA4DE3U $ Price 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 26.20 Diode Coil Suppressor • • • No overvoltage or oscillating frequency Polarized component Increased drop-out time (6 to 10 times normal) Table 18.22: Diode for reduction of “electrical noise” in DC contactor coils Installed on the upper part by Snap-on mounting and connection w/o tools to the contactor coil terminals LA4DC3U Screw connection of wire to the contactor coil terminals Mounting on LC●D12, D25 (4P) LC●D40 to D80 (3P) LC●D40 to D80 (4P) Operating voltage DC 24–250 V Catalog Number LA4DC1U 24–250 V LA4DC3U $ Price 26.20 26.20 Bidirectional Diode Coil Suppressor • • Protection provided by limiting the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks Table 18.23: Bidirectional peak limiting diode Installed by Mounting on Operating Voltage 50/60 Hz and DC Catalog Number $ Price 24 (AC only) LAD4TB 26.20 72 (AC only) LAD4TS 26.20 24 (AC only) LA4DB2B 56.00 72 (AC only) LA4DB2S 26.20 Screw Mounting d LC●D40 to LC●D80 24 (DC only) LA4DB3B 56.00 72 (DC only) LA4DB3S 56.00 b Installing suppressor into the cavity makes the electrical connection. Overall width of contactor remains the same. c For LC●D09 through LC●D32 with DC or low consumption DC coils, 3-pole contactors are fitted with built-in bidirectional diode suppression as standard. d Mounting at the top of the contactor on coil terminals A1 and A2. LC●D09 to LC●D32 (3P)c Snapping into cavity on right side of contactor b Table 18.24: LAD4BB• • © 2007 Schneider Electric All Rights Reserved Cabling Accessories Usage Mounting on For adapting existing wiring to a new product or for use with top mount accessory. LC1D09 to D38 LC1DT20 to DT60 AC only Operating voltage 50/60 Hz Without coil suppression 24-48 V With coil suppression 50-127 V (varistor) 110-250 V Catalog Number LAD4BB LAD4BBVE LAD4BBVG LAD4BBVU $ Price 23.00 23.00 23.00 23.00 D-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-2, 18-4 D-Line overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . .page 18-14 D-Line replacement coils. . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 I12 Discount Schedule Modified 4/16/09 18-7 IEC CONTACTORS AND STARTERS Limitation of transient voltage value to 200% of nominal voltage maximum Maximum reduction of transient voltage peaks Slight increase in drop-out time (1.1 to 1.5 times normal) 18 LA4DA2U • • • Contactor Accessories TeSys™ D-Line Electronic Timers and Interface Modules Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION The following accessories require use of cabling accessories (LAD4BB●●) for proper mounting. See page 18-7 for illustration. Electronic Serial Timer Modules These solid state modules delay the energizing and de-energizing of the contactor coil. Table 18.25: Type 100–250 Vac Time Delay 24–250 Vac-dc Catalog Number $ Price 0.1–2 s LA4DT0U 1.5–30 s LA4DT2U 25–500 s LA4DT4U For 24 V operation, the contactor must be fitted with a 21 V coil: coil voltage code Z5 for 50 Hz; Z6 for 60 Hz; ZD for DC. On-delay a Operational Voltage a 24–250 Vac LC1D09–D32 LC1D40–D150 82. 82. 82. LP1D09–D32 Interface Modules These modules allow the contactor coils to be energized from low voltage and low current level signals. They come in mechanical relay and solid state versions. The relay plus manual operation versions include a lever for manually turning the contactor on and off. When a module receives a low level signal, it allows the separate sourced control voltage to flow to the contactor coil. It saves space and wiring time compared to conventional interposing relays. Table 18.26: 18 Interface Type Relay LA4DMU IEC CONTACTORS AND STARTERS Relay Plus Manual Operation Solid State Operational Voltage 24–250 Vac LC1D09–D150 LC1D09–D150 LC1D09–D150 LC1D09–D150 LC1D09–D32 100–250 Vac 24–250 Vdc LP1D09–D32 LP1D09–D32 LP1D09–D32 LP1D09–D32 LC1D40–D115 Input Voltage Catalog Number 24 V 48 V 24 V 48 V 24 V LA4DFB LA4DFE LA4DLB LA4DLE LA4DWB $ Price 55. 55. 71. 71. 71. Automatic-Manual-Stop Control Modules These modules allow for local and/or remote operation of the contactor coil. Each module includes a lever to switch from automatic to manual operation and a dial to turn the contactor on and off. Table 18.27: Operational Voltage 24–100 Vac LC1D09–D150 — LA4DFB 100–250 Vac — LC1D09–D150 24–100 Vdc LP1D09–D32 — Catalog Number 100–250 Vdc — LP1D09–D32 LA4DMK LA4DMU $ Price 35. 35. Low Voltage Ride Through Module (meets SEMI F47 requirements) By ensuring SEMI F47 compliance of AC powered IEC contactors and relays, the low voltage ride through modules can be used to increase the voltage sag immunity of semiconductor processing equipment. These modules make it possible for AC powered Telemecanique contactors and relays to exceed the requirements of SEMI F47, both in the magnitude and duration of a voltage sag event—even with accessories such as auxiliary contact blocks and pneumatic timers. The low voltage ride through modules can be used with Telemecanique contactors from 9 A through 80 A, as well as the CAD series of control relays Table 18.28: For use on: Contactor Catalog Number Relay $ Price LC1D●●B7 CAD●●B7 LADLVRT24V b 124. CAD●●G7 LADLVRT120V b 124. LC1D●●G7 CAD●●LE7 LADLVRT208V b 124. LC1D●●LE7 Top mount bracket (required when using above modules) LAD4BB b 23. Fuse LA9D941 120. b LAD4BB must be used when the low voltage ride through module is being used with contactors 32 A and less, and TeSys CAD Series of Control Relays. D-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-2, 18-4 D-Line overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 D-Line replacement coils . . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 LADLVRT E1 LADLVRT E1 A1 E2 A1 E2 1.25 32 A2 A2 A1 1.85 47 A2 LAD4BB Contactors 32 A and less 18-8 Contactors 40 A–80 A I12 Discount Schedule Modified 4/16/09 © 2007 Schneider Electric All Rights Reserved Contactor Accessories TeSys™ D-Line and F-Line Accessories Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION For Power Pole or Control Connection 4 poles 3 poles Connectors for larger cable sizes #8 AWG (10 mm2) #4 AWG (25 mm2) LA9D1260 2 poles Links for the parallel connection of 3 poles (Wye-Delta Shorting Strap) LA9D2561 4 poles Second coil connection Control circuit take-off from main pole Spreaders for increasing pole pitch to 45 mm Table 18.30: Reference label holder snap-on 8 x 22 mm Sheet of 300 labels self adhesive 7 x 21 mm Table 18.31: Set of shims for mounting LA8DN 35 mm DIN Rail – 2 meters long D09, D12 D09–D32 D09–D32 D40, D50, D65 D80 F115 F150, F185 F265, F330, F400 F500 F630, F800 D09–D32 D80 F115 F150, F185 F265, F330, F400 F500 F630, F800 D40, D50, D65 D80 LP1D40–D80 LP1D40–D65 LPD80 D115, D150 1 1 10 2 2 4 4 4 4 4 10 1 1 1 1 1 1 2 2 10 10 10 3 LA9D1260 LA9D3260 LA9D2561 LA9D40961 LA9D80961 LA9FF602 LA9FG602 LA9FH602 LA9FK602 LA9FL602 LAD9P3 LA9D80962 LA9FF601 LA9FG601 LA9FH601 LA9FK601 LA9FL601 LA9D40963 LA9D80963 LA9D09966 LA9D6567 LA9D8067 GV7AC03 For use with contactors LC1/LP1 4-pole contactors LC1D65 & D80 For holder LA9D92 Sold in lots of Catalog Number 100 LA9D92 .06 1 LA9D93 4.30 For use with contactors LC1/LP1 LC1D40 to D80 LC1D09 to D80 Sold in lots of Catalog Number $ Price each 1 10 LA9D511 AM1DP200 $ Price 3 poles 3 poles 4 poles Catalog Number LA5D1158031 LA5D150803 LA5D115804 $ Price 3 poles 3 poles 4 poles Catalog Number LA5D11550 LA5D15050 LA5D115480 $ Price each 8.70 12.00 26.20 5.50 6.50 55.00 65.00 169.00 228.00 278.00 10.00 6.50 6.80 8.20 12.00 21.80 38.20 15.30 17.50 2.20 4.30 5.50 31.10 $ Price each 9.80 5.20 Replacement contacts For use with contactors LC1D115 LC1D150 LC1D115 Three-pole Four-pole Table 18.33: Catalog Number For Mounting Description Table 18.32: Sold in lots of For Marking Description LA9D40961 For use with contactors LC1/LP1 239.00 239.00 318.00 Arc chambers LA9D6567 For use with contactors LC1D115 LC1D150 LC1D115 Three-pole Four-pole 90.00 90.00 119.00 D-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-2, 18-4 D-Line overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . .page 18-14 D-Line replacement coils. . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47 F-Line contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-3, 18-5 F-Line replacement coils and parts . . . . . . . . . . . pages 18-11, 18-17, 18-19 LA9D511 © 2007 Schneider Electric All Rights Reserved I12 Discount Schedule Modified 4/17/09 18-9 IEC CONTACTORS AND STARTERS Description 18 Table 18.29: Contactor Accessories TeSys™ F-Line Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.34: LA9D09981 Suppressor Blocks Operating limit: up to 220 V, 50/60 Hz coils Description For Use Catalog Number With coils LX1FF, FG, FH, F115, F185, F265, F330 LA9F980 Suppressor block (clip-on mounting to coil) With coils LX1FJ, FK, FL, FX, F400, F500, F630, F780, LX9FF, FG, FH, F115, F185, F265, F330 LA9D09980 Mounting bracket (for 35 mm DIN rail or panel mounting) for suppressor block LA9D09981 Table 18.35: LA9F980 a Lugs—3-Pole a Contactor Lug Kit Cable Size AL/CU $ Price Type LC1 Catalog Number F115 DZ2FF6 14 to 2/0 39.30 F150, F185 DZ2FG6 6 to 3/0 65.00 F265, F330 DZ2FH6 6 to 300 MCM 65.00 F400 DZ2FJ6 4 to 500 MCM 65.00 F500 DZ2FK6 2 X 2 to 600 MCM 131.00 F630, F800 DZ2FL6 3 X 2 to 600 MCM 164.00 F780 DZ2FX6 4 X 1/0 to 750 MCM 163.80 Lugs for LC1F must be ordered separately. Each kit consists of six (6) lugs. Mounting hardware (screws, washers, nuts) are provided with the contactor, not the lugs. Table 18.36: Lugs—2 and 4-Pole c 18 Contactor Type LC1 IEC CONTACTORS AND STARTERS b c $ Price 21.80 20.70 5.50 Lug Kit Catalog Number Qty. Required 2-Pole 4 4 4 4 4 b 4 4-Pole 8 8 8 8 8 N/A 8 AL/CU Cable Size $ Price each F115 DZ2FF1 14 to 2/0 6.50 F150, F185 DZ2FG1 6 to 3/0 11.00 F265, F330 DZ2FH1 6 to 300 MCM 11.00 F400 DZ2FJ1 4 to 500 MCM 11.00 F500 DZ2FK1 2 X 2 to 600 MCM 21.80 F630 DZ2FLb 3 X 2 to 600 MCM 27.30 F780 DZ2FX1 4 X 1/0 to 750 MCM 27.30 For 2-pole F630 contactors, order 2 DZ2FL1 (L1 and T2), and 2 DZ2FL3 (L2 and T1). For 4-pole F6304, order 2 DZ2FL1 (L1 and T4), 4 DZ2FL2 (L2, T2, L3, T3) and 2 DZ2FL3 (L4 and T1). Lugs for LC1F contactors and overload relays must be ordered separately. Each kit consists of one (1) lug. Mounting hardware (screws, washers, nuts) are provided with the contactors, not the lugs. These clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power terminals. They are designed to be used with power cables that have been bolted to the terminal. NOTE: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits. Table 18.37: Power Terminal Protection Shrouds For Use With 2-, 3-, And 4-pole Contactors LA9F70z LC1F115 LC1F150, F185, CR1F150, F185 LC1F225, F265, F330, F400 and F4002, F500 and F5002, CR1F265, F400 and F500 LC1F630, F6302 and F800, CR1F630 LC1F1154 LC1F1504 and F1854 LC1F2254, F2654, F3304, F4004, F5004 LC1F6304 Number of Shrouds Per Set 6 6 6 6 8 8 8 8 Catalog Number $ Price LA9F701 LA9F702 LA9F703 LA9F704 LA9F706 LA9F707 LA9F708 LA9F709 42.40 61.00 82.00 93.00 58.00 80.00 111.00 120.00 F-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-3, 18-5 F-Line overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 F-Line replacement coils and parts . . . . . . . . . . . .pages 18-11, 18-17, 18-19 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47 18-10 I12 Discount Schedule Modified 4/17/09 © 2007 Schneider Electric All Rights Reserved Replacement Parts TeSys™ F-Line Contact Kits, Arc Chambers Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Replacement contact sets a Catalog Number LA5F400802 LA5F500802 LA5F630802 LA5FF431 LA5FG431 LA5FH431 LA5F400803 LA5F500803 LA5F630803 LA5F780801d LA5F800803 LA5FF441 LA5FG441 LA5FH441 LA5F400804 LA5F500804 LA5F630804 LA5F780801d $ Price 717. 1111. 1651. 239. 418. 793. 1076. 1589. 2488. 1651. 2488. 318. 549. 966. 1435. 2461. 3304. 1651. For use on contactors Catalog Number LC1F4002 2 poles LA5F400250 Two-pole LC1F5002 2 poles LA5F500250 LC1F6302 2 poles LA5F630250 LC1F115 3 poles LA5F11550 LC1F150 3 poles LA5F15050 LC1F185 3 poles LA5F18550 LC1F265 3 poles LA5F26550 LC1F330 3 poles LA5F33050 Three-pole LC1F400 3 poles LA5F40050 LC1F500 3 poles LA5F50050 LC1F630 3 poles LA5F63050 LC1F780 1 pole LA5F780150d LC1F800 3 poles LA5F80050 LC1F1154 4 poles LA5F115450 LC1F1504 4 poles LA5F150450 LC1F1854 4 poles LA5F185450 LC1F2654 4 poles LA5F265450 Four-pole LC1F3304 4 poles LA5F330450 LC1F4004 4 poles LA5F400450c LC1F5004 4 poles LA5F500450c LC1F6304 4 poles LA5F630450b LC1F7804 1 pole LA5F780150d Supplied per pole are: 2 fixed contacts, 1 moving contact, 2 deflectors, 1 backplate, mounting screws and washers. Comprises single-pole components. Comprises 2-pole components. 2 identical components per pole are supplied. $ Price 280. 305. 431. 90. 101. 179. 269. 287. 305. 341. 646. 431. 750. 119. 131. 248. 299. 414. 573. 610. 861. 431. Two-pole Three-pole LA5FG431 Four-pole LA5F11550 a b c d 2 poles 2 poles 2 poles 3 poles 3 poles 3 poles 3 poles 3 poles 3 poles 1 pole 3 poles 4 poles 4 poles 4 poles 4 poles 4 poles 4 poles 1 pole Arc chambers F-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-3, 18-5 F-Line overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . .page 18-14 F-Line replacement coils and parts . . . . . . . . . . . pages 18-11, 18-17, 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47 © 2007 Schneider Electric All Rights Reserved I12 Discount Schedule Modified 4/16/09 18-11 IEC CONTACTORS AND STARTERS Table 18.39: For use on contactors LC1F4002 LC1F5002 LC1F6302 LC1F115, F150 LC1F185 LC1F265 LC1F330, F400 LC1F500 LC1F630 LC1F780 LC1F800 LC1F1504, F1154 LC1F1854 LC1F2654 LC1F3304, F400, F4004 LC1F5004 LC1F6304 LC1F7804 18 Table 18.38: Contactors Accessories TeSys™ D-Line Reversing Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.40: Contactors Mechanical interlock Reversing contactors comprising two identical, horizontally mounted contactors: LC1D09, LC1D12, LC1D18, LC1D25, LC1D32 LC1DT20, LC1DT25, LC1DT32, LC1DT40 Catalog Number $ Price Set of power connections With incorporated electrical interlock (2 N.C. contacts) Without electrical interlock Catalog Number Reversing contactors for motor control $ Price Catalog Number Four pole contactors $ Price Catalog Number 32.10 LAD9R1V 45.50 Included with kit Not Available 36.90 LADT9R1V 45.50 Not Available Included with kit LA9D50978 31.70 LA9D4002 45.90 18 LAD9R1 LADT9R1 $ Price IEC CONTACTORS AND STARTERS LC1D40, LC1D50, LC1D/LP1D65 LA9D6569 53.00 LA9D6570 63.00 LC1D80 AC LA9D50978 31.70 LA9D4002 45.90 LA9D8069 65.00 LA9D8070 79.00 LC1D80 DC LA9D80978 31.70 LA9D8002 65.00 LA9D8069 65.00 LA9D8070 79.00 LA9D11502 78.00 LA9D11569 129.00 LA9D11571 (3P) LA9D11570 (4P) (D115 only) 53.00 LC1D115 and LC1D150 Not Available 53.00 D-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-2, 18-4 D-Line overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 D-Line replacement coils . . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 18-12 I12 Discount Schedule Modified 4/16/09 © 2007 Schneider Electric All Rights Reserved Contactors Accessories TeSys™ F-Line Reversing Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Component parts for the assembly of F-Line 3-pole reversing contactors Set of Power Connections Catalog Number Horizontal Mounting LC1F115 LC1F150 LC1F185 LC1F265 LC1F330 LC1F400 LC1F500 LC1F630 or F800 Vertical Mounting LC1F115 or F150 LC1F185 LC1F265 LC1F330 LC1F400 LC1F500 LC1F630 or F800 LC1F780 LA9F•970 LA9F•976 Table 18.42: LA9F•977 d d d d d d d b Table 18.43: Three-Pole Four-Pole LA9FF982 LA9F15082 LA9FG982 LA9FH982 LA9FJ982 LA9FJ982 LA9FK982 LA9FL982 LA9FF977 LA9F15077 LA9FG977 LA9FH977 LA9FJ977 LA9FJ977 LA9FK977 LA9FL977 d d d d d d d b d d d d d d d c Lower Contactor e LC1F185 or 1854 LC1F265 or 2654 LC1F330 or 3304 L2 L3 A1 A2 A1 1 3 5 1 3 5 2 4 6 2 4 6 U V A2 W Reversing (motors) Application 1N 1L2 1L3 A1 A2 2L1 1L1 53. 53. 53. 76. 76. 76. 76. 76. LA9FF4F LA9FG4G LA9FH4H LA9FJ4J LA9FJ4J LA9FK4K LA9FL4L LA9FX970 b 97. 113. 126. 149. 149. 149. 149. 508. $ Price 53.00 53.00 53.00 83.00 113.00 113.00 154.00 233.00 — — — — — — — — Mechanical Interlock Kit Catalog Number LA9FF970 LA9FF970 LA9FG970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FL970 LA9FF4F LA9FG4G LA9FH4H LA9FJ4J LA9FJ4J LA9FK4K LA9FL4L LA9FX970 c $ Price 53. 53. 53. 76. 76. 76. 76. 76. 97. 113. 149. 149. 149. 149. 149. 508. Vertical mounting of 2 contactors of different ratings a Upper Contactor L1 — — — — — — — — LA9FF970 LA9FF970 LA9FG970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FJ970 LA9FL970 Set of Power Connections LC1F115/4 LC1F150/4 LC1F185/4 LC1F265/4 LC1F330/4 LC1F400/4 LC1F500/4 LC1F630/4 Vertical Mounting LC1F115/4 LC1F185/4 LC1F265/4 LC1F330/4 LC1F400/4 LC1F500/4 LC1F630/4 LC1F780/4 LA9FX970 106.00 96.00 113.00 151.00 225.00 225.00 306.00 568.00 $ Price Component parts for the assembly of F-Line 3-pole or 4-pole transfer contactors Horizontal Mounting LA9F•4• LA9FF976 LA9F15076 LA9FG976 LA9FH976 LA9FJ976 LA9FJ976 LA9FK976 LA9FL976 Mechanical Interlock Kit Catalog Number $ Price Mechanical Interlock Kit Catalog Number LA9FG4F LA9FH4F LA9FH4G LA9FJ4F LA9FJ4G LA9FJ4H LA9FK4F LA9FK4G LA9FK4H LA9FK4J LA9FL4F LA9FL4G LA9FL4H LA9FL4J LA9FL4K LC1F115/150 or 1154/1504 LC1F115/150 or 1154/1504 LC1F185/1854 or 265/265A LC1F115/150 or 1154/1504 LC1F400 or 4004 LC1F185 or 1854 LC1F265/2654 or 330/330A LC1F115/150 or 1154/1504 LC1F185 or 1854 LC1F500 or 5004 LC1F265/2654 or 330/330A LC1F400 or 4004 LC1F115/150 or 1154/1504 LC1F185 or 1854 LC1F630, 6304 or LC1F265/2654 or 330/330A LC1F800 LC1F400 or 4004 LC1F500 or 5004 a With identical or different numbers of poles. b Double mechanical interlock with 2 mechanical links and 3 power connection bars. c Double mechanical interlock with 2 mechanical links and 4 power connection bars. d Power connection to be assembled by the customer, except for contactors LC1F780 and F7804. e Lower contactor must have equal or lower current rating. $ Price 113. 126. 126. 126. 126. 149. 149. 126. 149. 149. 116. 126. 149. 149. 149. 2L3 2L2 2N 1 3 5 7 1 3 5 7 2 4 6 8 2 4 6 8 A1 A2 F-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-3, 18-5 F-Line overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 F-Line replacement coils and parts . . . . . . . . . . . . . . . .pages 18-16 to 18-18 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-42 to 18-47 L1 L2 L3 N Transfer/Changeover Applications © 2007 Schneider Electric All Rights Reserved I12 Discount Schedule Modified 4/16/09 18-13 IEC CONTACTORS AND STARTERS With 2 Identical Contactors a 18 Table 18.41: Overload Relays TeSys™ D-Line and F-Line Overload Relay Accessories Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION D-Line Overload Relay Accessories Table 18.44: Mounting Kits and Platesa Description LA7D901 For use with overload relays: LRD01–35 and LR3D01–35 LRD01–35 and LRD01–35 for ring tongue terminals Separate mounting kits for mounting to 35 mm LRD15•• omega rail or for panel mounting with screws LR2D15•• LR2D25•• LRD3•••, LR3D3•••, LR2D35•• LRD01–35, LR3D01–35, LR2D15•• Mounting plates for screw mounting LR2D25•• at 110 mm (4.3") centers LRD3•••, LR3D3••, LR2D35•• a When using mounting plates, separate mounting kits are also required. Table 18.45: Catalog Number LAD7B10 LAD7B106 8.70 LAD7B105 LA7D1064 LA7D2064 LA7D3064 DX1AP25 DX1AP26 LA7D902 10.40 8.70 13.10 17.50 11.00 12.00 16.40 Accessories Description Standard Packaging 10 10 For use with 18 Pre wiring kit allows direct connection of the N.C. contact LC1D09 through D18 of relay LRD01–D32 or LR3D01–D32 to the contactor LC1D25, D32 All relays except LRD01–D32, LR3D01–D32 and Stop button locking device LR9D LRD01–D32, LR3D01–32 Remote stop/tripping or electrical resetc All relays except LRD01–D32, LR3D01–D31 Reset by flexible cable 500 mm (19.6 in.) LRD01–D32 b Part number to be completed by adding coil voltage code. For example: LAD703F. IEC CONTACTORS AND STARTERS LA7D03 Table 18.46: c d $ Price 8.70 Catalog Number $ Price LAD7C1 LAD7C2 8.70 8.70 10 LA7D901 2.20 1 1 1 LAD703b LA7D03b LAD7305 43.70 43.70 100.00 Control Circuit Voltages for LA7D03 and LAD703 Volts 12 24 48 110 220/230 380/400 415/440 AC 50/60 Hz Jd B E F M Q N DC J B E F M — — The time that the LA7D03 can remain energized depends on its rest time; 1 s pulse wth 9 s rest time; 5 s pulse with 30 s rest time; 10 s pulse with 90 s rest time; maximum pulse duration of 20 s with rest time of 300 s. Consumption on inrush and sealed : < 100 VA Not available for LRD01-D32, LR3D01-D32. F-Line Overload Relay Accessories Table 18.47: Mounting plate for overload relay For use with relays LR9F5•57, F5•63, F5•67, F5•69 and F5•71 LR9F7•75, F7•79 and F7•81 Catalog Number LA7F901 LA7F902 $ Price 27.30 38.20 LA7F90• These clear plastic protective shrouds are an effective means to meet international finger-safe requirements for power terminals. They are designed to be used with power cables that have been bolted to the terminal. NOTE: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits. Table 18.48: Power terminal protection shrouds, single-pole For use with relays LR9F5•57 LR9F5•63, F5 67, F5•69 LR9F5•71 LR9F7•75, F7•79, F7•81 t Table 18.49: LR9F5•57, F5•63, F5•67, F5•69 LR9F5•71 LR9F7•75, F7•79, F7•81 Table 18.50: For relays LR9F5•57, F5•63, F5•67, F5•69 LR9F5•57, F5 63 LR9F5•71 LR9F7•75, F7 •• 79 LR9F7•81 LR9F7•75, F7•79, F7•81 LR9F7•81 e Mounting plate required. For contactor LC1F115 LC1F150 and F185 LC1F265 LC1F265...F400 LC1F400 LC1F500 LC1F630 t Table 18.51: Catalog Number LA7F701 LA7F702 LA7F703 $ Price 27.30 38.20 49.20 Connection accessories (for mounting overload relays beneath reversing contactors)e Application LA7F701 $ Price 42.40 61.00 86.00 82.00 Power terminal protection shrouds, 3-pole For use with relays LA9F70• Catalog Number LA9F701 LA9F702 LA9F705 LA9F703 Set of 3 bars Catalog Number LA7F401 LA7F402 LA7F403 LA7F404 LA7F404 LA7F405 LA7F406 $ Price 19.70 21.80 27.30 30.50 30.50 38.20 43.70 Marking accessories Description Marker holder, snap-in Sold in units of: 100 Catalog Number LA7D903 $ Price .03 each Main overload selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pages 18-2, 18-3 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-45 to 18-47 18-14 I12 Discount Schedule © 2007 Schneider Electric All Rights Reserved Overload Relays TeSys™ D-Line and F-Line Lug Kits Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Lug Kits Lugs can be ordered either individually or in sets of 6. In some cases the LR9F overload relay mounted directly on the load side of an LC1F contactor will require a different size lug for your choice of contactor and overload. If all 6 lugs (three for line side of contactor, three for load side of overload relay) are the same, Square D offers a prepackaged set of six lugs. If the two sizes are different, order 3 of each size lug. Mounting hardware (screws, washers, and nuts) are provided with the contactors and overload relays, not with the lugs. Table 18.52: Overload Relay Directly mounted to contactor LR9F5•57 to F5•69 LR9F5•57 to F5•71 LR9F5•71 LR9F7•75 to F7•79 LR9F7•75 to F7•81 LR9F7•75 to F7•81 LR9F7•81 F115 F150 to F185 F265 F265 or F330 F400 F500 F630 Line side of contactor 14 to 2/0 LC1• — — F780 F800 Lugs Required Lug Catalog Number Line side of Load side of contactor overload 3 each DZ2FF1 3 each DZ2FG1 1 each DZ2FG6 1 each DZ2FH6 3 each DZ2FH1 1 each DZ2FR1 3 each DZ2FJ1 1 each DZ2FR1 3 each DZ2FK1 1 each DZ2FR1 1 each DZ2FL1 1 each DZ2FR1 DZ2FL2 DZ2FL3 DZ2FF1 6.50 DZ2FG1 DZ2FG6 DZ2FH1 DZ2FJ1 DZ2FK1 DZ2FL1 DZ2FL2 11.00 65.00 11.00 11.00 21.80 27.30 55.00 Cable size AWG range Load side of overload 6 to 3/0 6 to 3/0 6 to 300 MCM 6 to 300 MCM 4 to 500 MCM 4 to 500 MCM 4 to 500 MCM 2x2 to 600 MCM 4 to 500 MCM 3x2 to 600 MCM 4 to 500 MCM 4x2 to 600 MCM 4x2 to 600 MCM — — 3 each DZ2FX1 3 each DZ2FX1 $ Price DZ2FL3 27.30 DZ2FR1 173.00 DZ2FX1 27.30 For contactors LC1F115, LC1F150, and LC1F185, an available touch-safe terminal block may be used in place of lugs for power connections. Table 18.53: For contactor type LC1 F115, F150, F185 For overload relay LR9 F5•57, F5•63, F5•67, F5•69 Maximum Cable Size 300 MCM Catalog Number LA9F103 $ Price 55.00 IEC CONTACTORS AND STARTERS Insulated Terminal Blocks 18 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47 © 2007 Schneider Electric All Rights Reserved I12 Discount Schedule Modified 4/16/09 18-15 Contactors Repair Parts TeSys™ D-Line AC Coils Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.54: 18 LX1D2 For LC1D09–D32, LC1DT20–40 (TeSys™) Contactors and CAD Relays IEC CONTACTORS AND STARTERS Rated Nominal Voltage Catalog Number 50/60 Hz 12 21a 24 32 36 42 48 60 100 110 115 120 127 200 208 220/230 230 230/240 277 380/400 400 415 440 480 575 600 690 LXD1J7 LXD1Z7 LXD1B7 LXD1C7 LXD1CC7 LXD1D7 LXD1E7 LXD1EE7 LXD1K7 LXD1F7 LXD1FE7 LXD1G7 LXD1FC7 LXD1L7 LXD1LE7 LXD1M7 LXD1P7 LXD1U7 LXD1W7 LXD1Q7 LXD1V7 LXD1N7 LXD1R7 LXD1T7 LXD1SC7 LXD1X7 LXD1Y7 Specifications $ Price 26.20 26.20 26.20 26.20 26.20 26.20 50/60 Hz Average consumption - Inrush (inductance .75) - Sealed (inductance .3) 70 VA 7 VA 80–110% of nominal @ 50 Hz, Operating range@ 60 C 85–110% of nominal @ 60 Hz Voltage for special coils fitted in contactors with serial timer modules, with 24 V supply. o a Table 18.56: Table 18.55: For LC1D09, D12, D18—For old style contactors where the catalog number includes the auxilary contact arrangement Rated Nominal Voltage V Catalog Number 50 Hz LX1D2Z5 LX1D2B5 LX1D2C5 LX1D2D5 LX1D2E5 LX1D2F5 — LX1D2G5 — LX1D2M5 LX1D2P5 LX1D2U5 LX1D2W5 — LX1D2Q5 LX1D2V5 LX1D2N5 LX1D2R5 — LX1D2S5 — — LX1D2Y5 Catalog Number 60 Hz LX1D2Z6 LX1D2B6 — — LX1D2E6 LX1D2F6 LX1D2G6 — LX1D2L6 LX1D2M6 — LX1D2U6 — LX1D2W6 LX1D2Q6 — — LX1D2R6 LX1D2T6 — LX1D2S6 LX1D2X6 — 21 b 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 Specifications Average 50 Hz 60 Hz consumption Inrush 60 VA 70 VA (inductance .75) Sealed 7 VA 7.5 VA (inductance .3) 80–110 % of 80–110% of Operating range at θ < 55oC / 131oF nominal voltage nominal voltage Catalog Number 50/60 Hz LX1D2Z7 LX1D2B7 — LX1D2D7 LX1D2E7 LX1D2F7 LX1D2G7 — — LX1D2M7 LX1D2P7 LX1D2U7 — — LX1D2Q7 LX1D2V7 LX1D2N7 LX1D2R7 — — — — — $ Price 52.40 52.40 52.40 52.40 52.40 50/60 Hz 70 VA at 50 or 60 Hz 8 VA at 50 or 60 Hz 85–110% of nominal voltage For LC1D25, D32—For old style contactors where the catalog number includes the auxiliary contact arrangement Rated Nominal Voltage (V) Catalog Number 50 Hz Catalog Number 60 Hz Catalog Number 50/60 Hz LX1D4Z5 LX1D4B5 LX1D4C5 LX1D4D5 LX1D4E5 LX1D4F5 — LX1D4G5 — LX1D4M5 LX1D4P5 LX1D4U5 LX1D4W5 — LX1D4Q5 LX1D4V5 LX1D4N5 LX1D4R5 — LX1D4S5 — — LX1D4Y5 LX1D4Z6 LX1D4B6 — — LX1D4E6 LX1D4F6 LX1D4G6 — LX1D4L6 LX1D4M6 — LX1D4U6 — LX1D4W6 LX1D4Q6 — — LX1D4R6 LX1D4T6 — LX1D4S6 LX1D4X6 — LX1D4Z7 LX1D4B7 — LX1D4D7 LX1D4E7 LX1D4F7 LX1D4G7 — — LX1D4M7 LX1D4P7 LX1D4U7 — — LX1D4Q7 LX1D4V7 LX1D4N7 LX1D4R7 — — — — — 50 Hz 60 Hz 50/60 Hz 90 VA 7.5 VA 100 VA 8.5 VA 100 VA at 50 or 60 Hz 8.5 VA at 50 or 60 Hz 80–110% of nominal voltage 85–110% of nominal voltage 21b 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 $ Price 72.00 72.00 72.00 72.00 72.00 Specifications Average consumption - Inrush (inductance .75) - Sealed (inductance .3) b 80–110% of Operating range nominal voltage at θ < 55oC / 131oF For use in 24 volt applications involving serial timer modules refer to page 18-8. D-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-2, 18-4 D-Line overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 D-Line replacement coils . . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 18-16 I12 Discount Schedule © 2007 Schneider Electric All Rights Reserved Contactors Repair Parts TeSys™ D- and F-Line AC Coils Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Specification Average consumption: -inrush (inductance .75) -sealed (inductance .3) Operating range at θ < 55oC / 131oF Catalog Catalog Number Number 50 Hz 60 Hz LX1D6B5 LX1D6B6 LX1D6C5 — LX1D6D5 — LX1D6E5 LX1D6E6 LX1D6F5 LX1D6F6 — LX1D6G6 LX1D6G5 — — LX1D6L6 LX1D6M5 LX1D6M6 LX1D6P5 — LX1D6U5 LX1D6U6 LX1D6W5 — — LX1D6W6 LX1D6Q5 LX1D6Q6 LX1D6V5 — LX1D6N5 — LX1D6R5 LX1D6R6 — LX1D6T6 LX1D6S5 — — LX1D6S6 — LX1D6X6 LX1D6Y5 — 50 Hz Catalog Number 50/60 Hz $ Price LX1D6B7 — LX1D6D7 LX1D6E7 LX1D6F7 LX1D6G7 — LX1D6LE7 LX1D6M7 LX1D6P7 LX1D6U7 — — LX1D6Q7 LX1D6V7 LX1D6N7 LX1D6R7 — — — — — 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 41.50 170.00 41.50 41.50 41.50 41.50 41.50 41.50 170.00 41.50 41.50 41.50 60 Hz 50/60 Hz 200 VA 220 VA 20 VA 22 VA 80–110% of 80–110% nominal of nominal voltage voltage 245 VA at 50 or 60 Hz 26 VA at 50 or 60 Hz 85–110% of nominal voltage For LC1D115, D150a Rated Nominal Voltage V 24 32 42 48 110 115 120 127 208 220/230 230 240 277 380/400 400 415 440 480 500 Catalog Number 50 Hz LX1D8B5 LX1D8C5 LX1D8D5 LX1D8E5 LX1D8F5 LX1D8FE5 — LX1D8FC5 — LX1D8M5 LX1D8P5 LX1D8U5 — LX1D8Q5 LX1D8V5 LX1D8N5 LX1D8R5 — LX1D8S5 Catalog Number 60 Hz LX1D8B6 — — LX1D8E6 LX1D8F6 — LX1D8G6 — LX1D8LG LX1D8M6 — LX1D8U6 LX1D8W6 LX1D8Q6 — — LX1D8R6 LX1D8T6 — Specification Average consumption: -inrush (inductance .3) -sealed (inductance .3) 50 Hz 60 Hz Catalog Number 50/60 Hz LX1D8B7 LX1D8C7 LX1D8D7 LX1D8E7 LX1D8F7 LX1D8FE7 LX1D8G7 LX1D8FC7 LX1D8L7 LX1D8M7 LX1D8P7 LX1D8U7 LX1D8W7 LX1D8Q7 LX1D8V7 LX1D8N7 LX1D8R7 LX1D8T7 LX1D8S6 $ Price 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 78.00 50/60 Hz 300 VA 300 VA 350 Va (Inductance: .9) 22 VA 22 VA 18 Va (Inductance: .9) 85–110% 85–110% Operating range at 80–115% of nominal of nominal θ < 55oC / 131oF of nominal voltage voltage voltage a For old style and new TeSys style contactors where the catalog number may or may not include the auxiliary contact arrangement. Table 18.59: For LC1F115, F150, F185, F265, F330, F400, F500, F630, F780, F800 — LX1 coils are the standard coils that are included when a voltage code is added to the contactor part number. The LX9 coils may be ordered separately for special applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with a N.O. contact should be added to the contactor. Both the LX1 and LX9 coils can be used on the previous F-line contactors. Device Type Hz Catalog Number 24 V 48 V 110 V 120 V 208 V 50 LX1FF• 024 048 110 127 200 F115–F150 020 040 092 095 162 60 LX1FF• 40–400 LX9FF• — 048 110 127 200 50 LX1FG• 024 048 110 127 200 F185 020 040 092 095 162 60 LX1FG• 40–400 LX9FG• — 048 110 127 200 40–400 LX1FH• 0242 0482 1102 1272 2002 F265–F330 — 0482 1102 1272 2002 40–400 LX9FH• 40–400 LX1FJ• — 048 110 110 200 F400c 40–400 LX9FJ• e 910 917 925 925 930 — 048 110 110 200 40–400 LX1FK• F500c 40–400 LX9FK• e 910 917 925 925 930 40–400 LX1FL• — 048 110 110 200 F630c 910 917 924 925 930 40–400 LX9FL• e F780, FX b 40–400 LX1FX• — — 110 110 200 F800 50/60 LX4F8• d — — FW FW — b LC1F780 contactors operate on 2 coils as a set. The LX1FX part number includes both coils. c The 600 V coils for the F400, F500 and F630 do not include an auxiliary contact for holding circuits. If required, select appropriate contacts from page 18-6. d Also requires rectifier DR5TE4U for 110 V–240 V coils, DR5TE4S for 380 V–440 V coils. See table below for pricing. e Coil circuit requires a separately mounted rectifier. Order from Rectifier Table. f Complete catalog number by adding suffix. For example: LX1FF024. Catalog Number Suffixf 220 V 240 V 277 V 380 V 415 V 440 V 480 V 600 V $ Price 220 184 220 220 184 220 2202 2202 220 931 220 931 220 930 220 MW 415 340 415 415 340 415 3802 3802 415 936 415 936 415 936 415 QW 415 360 415 415 360 415 4402 ... 415 937 415 937 415 936 415 QW 500 380 500 450 380 500 5002 5002 415 937 415 937 415 937 415 — 600 475 — 600 475 — 6002 — 600 — 600 — 600 — — — 78.00 78.00 78.00 108.00 108.00 108.00 138.00 138.00 287.00 287.00 360.00 360.00 398.00 483.00 795.00 725.00 240 187 220 240 187 220 2402 2402 240 932 240 932 240 931 220 MW 264 220 260 264 220 260 2772 2772 280 932 280 932 260 932 280 — Table 18.60: Coil LX9F•910 LX9F•917 LX9F•925 LX9F•926 LX9F•931 LX9F•936 LX9F•937 LX9F•938 380 316 380 380 316 380 3802 3802 380 936 380 936 380 935 380 QW Rectifier Table Rectifier Catalog Number DR5TF4V DR5TF4V DR5TE4U DR5TE4U DR5TE4U DR5TE4S DR5TE4S DR5TE4S $ Price 75.00 75.00 75.00 75.00 75.00 75.00 75.00 75.00 Application Note on Contactor Drop-out Times: Contactors using LX1, FH, FJ, FK, FL, and FX coils have longer drop-out times. For critical applications such as emergency stop functions: • • • © 2007 Schneider Electric All Rights Reserved Select a fast drop-out coil (LX9), or Use a maintained contact Stop button, or Use an interposing relay. I12 D-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-2, 18-4 F-Line contactors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-3, 18-5 D-Line overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . .page 18-14 D-Line replacement coils . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-47 Discount Schedule Modified 4/17/09 18-17 IEC CONTACTORS AND STARTERS LX1D6 Table 18.58: For LC1D40, D50, D65, D80a Rated Nominal Voltage V 24 32 42 48 110 120 127 208 220 230 240 256 277 380 400 415 440 480 500 575 600 660 18 Table 18.57: Contactors Repair Parts TeSys™ D-Line DC Coils Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.61: For LP1D09, D12, D18 Contactors a Rated Nominal Voltage V 12 21b 24 36 48 60 72 110 125 220 250 440 600 Number Catalog Number Catalog Wide range LX4D2JD LX4D2ZD LX4D2BD LX4D2CD LX4D2ED LX4D2ND LX4D2SD LX4D2FD LX4D2GD LX4D2MD LX4D2UD LX4D2RD LX4D2XD LX4D2JW — LX4D2BW LX4D2CW LX4D2EW — LX4D2SW LX4D2FW — LX4D2MW — — — $ Price 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 79.00 154.00 Table 18.63: For LP1D40, D50, D65 a Rated Nominal Voltage V Catalog Number Catalog Number Wide range 12 24 36 48 60 72 110 125 220 250 440 600 LX4D6JD LX4D6BD LX4D6CD LX4D6ED LX4D6ND LX4D6SD LX4D6FD LX4D6GD LX4D6MD LX4D6UD LX4D6RD LX4D6XD LX4D6JW LX4D6BW LX4D6CW LX4D6EW — LX4D6SW LX4D6FW — LX4D6MW — — — $ Price 124.00 124.00 124.00 Specifications Specifications 18 Average consumption Operating range at θ–55oC / 131oF Table 18.62: 9W 80–110% of nominal voltage Average consumption 22 W 23 W Operating range at 80–110% 75–120% θ < 55oC /131oF of nominal voltage of nominal voltage 11 W 70–125% of nominal voltage Table 18.64: For LP1D25, D32 a IEC CONTACTORS AND STARTERS Rated Nominal Voltage V Catalog Number 12 21 b 24 36 48 60 72 110 125 220 250 440 600 LX4D4JD LX4D4ZD LX4D4BD LX4D4CD LX4D4ED LX4D4ND LX4D4SD LX4D4FD LX4D4GD LX4D4MD LX4D4UD LX4D4RD LX4D4XD Catalog Number Wide range LX4D4JW — LX4D4BW LX4D4CW LX4D4EW — LX4D4SW LX4D4FW — LX4D4MW — — — $ Price 110.00 110.00 110.00 110.00 110.00 184.00 110.00 110.00 110.00 110.00 110.00 110.00 184.00 Specifications Average consumption 11 W 13 W Operating range at 80–110% of 70–125% of o o θ < 55 C / 131 F nominal voltage nominal voltage a For old style contactors where the catalog number includes the auxiliary contact arrangement (ex. LP1D2510). The new style TeSys DC controlled contactors (ex. LC1D25BD) do not have replaceable coils. b For use in 24 volt applications with serial timer modules. Refer to page 18-8. For LP1D80 and LC1D80a Rated Nominal Voltage V Number Catalog Number Catalog Wide Range c 12 24 36 48 60 72 110 125 220 250 440 600 LX4D7JD LX4D7BD LX4D7CD LX4D7ED LX4D7ND LX4D7SD LX4D7FD LX4D7GD LX4D7MD LX4D7UD LX4D7RD LX4D7XD LX4D7JW LX4D7BW LX4D7CW LX4D7EW — LX4D7SW LX4D7FW — LX4D7MW — — — $ Price 134.00 134.00 134.00 Specifications Average consumption 22 W 23 W Operating range 80–110% 70–120% o o at θ < 55 C / 131 F nominal voltage nominal voltage c Wide range coils cannot be used with contactors utilizing both front and side mount auxiliaries. Table 18.65: For LC1D115, 150 Rated Nominal Voltage V Catalog Number 24 48 60 72 110 125 220 250 440 LX4D8BD LX4D8ED LX4D8ND LX4D8SD LX4D8FD LX4D8GD LX4D8MD LX4D8UD LX4D8RD Average consumption Operating range at θ < 55oC / 131oF Inrush 365 W, Sealed 5 W 70%–120% of nominal voltage $ Price 78.00 78.00 D-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-2, 18-4 D-Line overload relay accessories. . . . . . . . . . . . . . . . . . . . . . . . . page 18-14 D-Line replacement coils . . . . . . . . . . . . . . . . . . . . . . . . pages 18-16 to 18-18 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-40 to 18-46 18-18 I12 Discount Schedule Modified 4/17/09 © 2007 Schneider Electric All Rights Reserved Contactors Repair Parts TeSys™ F-Line DC Coils Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION F-Line DC Coils LX4 coils are the standard coils when a voltage code is added to the part number. The LX9 coils may be ordered separately for special applications. LX9 coils do not include a built-in normally open holding circuit contact; a separate auxiliary contact block with a N.O. contact should be added to the contactor. Both the LX4 and LX9 coils can be used on previous F-line devices. Table 18.66: Device Type LX4 coils for LC1F115, F150, F185, F265, F400, F500, F630, F780, F800 • Catalog Number 24 V • • • • • • • • • • • F115, F150 F185 F265, F330 36V 48 V 60 V 72 V Catalog Number Suffix 110 V 125 V LX4FF 024 035 048 060 070 110 125 LX4FG 024 035 048 060 070 110 125 024 035 048 060 070 110 125 LX4FH LX4FJ — — 048 060 070 110 125 F400 LX9FJ c — — 918 — — 926 927 — — 048 060 070 110 125 LX4FK F500 LX9FK c — — 918 — — 926 927 — — 048 060 070 110 125 LX4FL F630 — — 918 — — 926 927 LX9FK c F780 LX4FX a — — — — — 110 125 F800 LX4F8 b — — — — — FW FW a LC1F780 contactors operate on 2 coils as a set. The LX4FX part number includes both coils. b Also requires rectifier DR5TE4U, $72.00 list price. c Coil Circuit requires a separately mounted resistor. Order from Table 18.67 below. 220 V 250 V 440 V 220 220 220 220 932 220 932 220 932 220 MW 250 250 250 250 — 250 — 250 — 250 — 440 440 440 440 938 440 938 440 938 440 QW $ Price 78.00 108.00 138.00 287.00 287.00 360.00 360.00 398.00 398.00 795.00 725.00 Coil Resistor Catalog Number LX9FJ918 LX9FJ926 LX9FJ927 LX9FJ932 LX9FJ938 DR2SC0047 DR2SC0030 DR2SC0390 DR2SC1200 DR2SC4700 Qty. Required $ Price 1 1 1 1 1 13.70 13.80 13.70 13.70 13.70 Coil Resistor Catalog Number Qty. Required LX9FK918 LX9FK926 LX9FK927 LX9FK932 LX9FK938 DR2SC0039 DR2SC0220 DR2SC0330 DR2SC1000 DR2SC3300 1 1 1 1 1 $ Price 13.70 13.70 13.70 13.70 13.70 Coil Resistor Catalog Number Qty. Required LX9FL918 LX9FL925 LX9FL926 LX9FL931 LX9FL937 DR2SC0047 DR2SC0270 DR2SC0330 DR2SC1000 DR2SC3900 2 2 2 2 2 $ Price 13.70 13.70 13.70 13.70 13.70 18 F-Line contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-3, 18-5 F-Line overload relay accessories . . . . . . . . . . . . . . . . . . . . . . . . .page 18-18 F-Line replacement coils and parts . . . . . . . . . . . pages 18-11, 18-17, 18-19 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-42 to 18-47 IEC CONTACTORS AND STARTERS Table 18.67: © 2007 Schneider Electric All Rights Reserved I12 Discount Schedule Modified 4/17/09 18-19 Enclosed Starters TeSys™ D-Line in Metal Enclosures Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION D-Line enclosed full voltage starters are available in Type 1 and Type 12/3R enclosures through 50 hp at 460 V. The enclosed D-line accepts standard D-Line accessories and all Insta-Kits™ control units and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure. For extra capacity, please refer to your local distributor or nearest Square D/Schneider Electric sales office. Table 18.68: Enclosed Full Voltage Non-reversing Starters Max. Horsepower Ratings (AC3) 1 Phase 3 Phase 115 230 200 V 230 V 460 V 575V 0.333 1 2 3 3 5 5 7.5 10 15 2 3 5 7.5 10 10 15 20 25 2 3 5 7.5 10 10 15 20 30 5 7.5 10 15 20 30 40 50 60 7.5 10 15 20 25 30 40 50 60 0.5 1 2 2 3 3 5 7.5 Table 18.69: Auxiliary Contacts Current Rating Catalog Number of Contactor N.O. N.C. Type 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 LE1D093A62••••• LE1D123A62••••• LE1D183A62••••• LE1D253A62••••• LE1D323A62••••• LE1D403A62••••• LE1D503A62••••• LE1D653A62••••• LE1D803A62••••• $ Price Type 12/3R 109. 137. 153. 170. 191. 273. 300. 393. 473. LE1D093A72••••• LE1D123A72••••• LE1D183A72••••• LE1D253A72••••• LE1D323A72••••• LE1D403A72••••• LE1D503A72••••• LE1D653A72••••• LE1D803A72••••• 175. 202. 219. 235. 245. 393. 420. 514. 610. Enclosed Full Voltage Reversing Starters 18 Auxiliary Contacts On Each Contactor Max. Horsepower Ratings (AC3) 3 Phase IEC CONTACTORS AND STARTERS 200V 230 V 460 V 575 V N.O. N.C. 2 3 5 7.5 10 10 15 20 25 2 3 5 7.5 10 10 15 20 30 5 7.5 10 15 20 30 40 50 60 7.5 10 15 20 25 30 40 50 60 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Table 18.70: 9 12 18 25 32 40 50 65 80 Catalog Number $ Price Current Rating Catalog Number of Contactor Type 1 9 12 18 25 32 40 50 65 80 LE2D093A62••••• LE2D123A62••••• LE2D183A62••••• LE2D253A62••••• LE2D323A62••••• LE2D403A62••••• LE2D503A62••••• LE2D653A62••••• LE2D803A62••••• Catalog Number $ Price $ Price Type 12/3R 305. 355. 385. 415. 464. 655. 710. 900. 1248. LE2D093A72••••• LE2D123A72••••• LE2D183A72••••• LE2D253A72••••• LE2D323A72••••• LE2D403A72••••• LE2D503A72••••• LE2D653A72••••• LE2D803A72••••• 382. 453. 483. 513. 573. 819. 874. 1030. 1412. Catalog Number Nomenclature Catalog Number Example: LE1D093A62 O M 7 1 07 Base Catalog Number Wiring Method f. Control Power Transformer f g. Contactor/Starter Coil Voltage g h. Coil Frequency h j. Overload Relay Type j i. Overload Relay Range i fControl Power Transformer Add price from page 18-22. Select letter for primary voltage of CPT: Voltage No Transformer used 208 240 480 600 Code Oa L M T X a Letter O, not zero. Note: If control transformer is used, the only options available are 24 or 120 volts as the secondary of the transformer. Also, DC voltages are not available when control power transformer is used. gContactor/Starter Coil Voltage Select coil voltage from table: Voltage 24 120 208 240 480 AC B G L U T X DC B — — — — — hCoil 600 Frequency Select: 7 = dual frequency coils (50/60 Hz.) 6 = 60 Hz. D=DC Note: For 9 to 32 A contactors, only dual frequency coils are available; 40 to 80 A contactors, the 24 V to 240 V coils are dual frequency only (50/60 Hz.). The 480 V to 600 V coils are 60 Hz. only. See catalog for other restrictions. jOverload relay type Select: 0 = No overload relay 1 = Class 10 Trip 2 = Class 20 Trip iOverload Relay Range Select code from the below: Code 01 02 03 04 05 06 07 08 10 12 14 16 21 Range For use on Contactors D09–D32b D09–D32b D09–D32b D09–D32b D09–D32b D09–D32b D09–D32b D09–D32 D09–D32 D09–D32 D09–D32 D12–D32 D18–D32 D25–D32b D25–D32c D40–D80 D25–D32c D25–D32 D40–D80 D40–D80 D40–D80 D40–D80 D40–D80 D40–D80 $ Price Adder 0.1–0.16 60. 0.16–0.25 60. 0.25–0.40 60. 0.40–0.63 60. 0.63–1.0 60. 1.0–1.6 60. 1.6–2.5 60. 2.5–4 60. 4–6 60. 5.5–8 60. 7–10 62. 9–13 62. 12–18 62. 16–24 62. 22 17–25 62. 17–25 107. 30 23-28 73. 32 23–32 73. 53 30–38 107. 55 30–40 107. 57 37–50 107. 59 48–65 107. 61 55–70 107. 63 63–80 107. b Available for Class 10 only. c Available for Class 20 only. Note: If no overload relay is required, leave this portion of the catalog blank. Add appropriate Price Adder to the base price of the starter. Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-48 18-20 I11 Discount Schedule Modified 4/16/09 © 2007 Schneider Electric All Rights Reserved Enclosed Combination Starters www.us.schneider-electric.com TeSys™ D-Line Fusible Disconnect Switch or Circuit Breaker Refer to Catalog 8502CT9901 FOR CURRENT INFORMATION IEC combination starters combine the requirements of motor overload and short circuit protection in one convenient compact package. All devices provide Type 2 Coordination through 30 hp at 460 V. Devices are available in Type 1 and Type 12/3R enclosures. The IEC combination starter line accepts standard D-Line accessories and all Insta-Kits™ pilot devices and control power transformer kits. Standard capacity control power transformers with built-in fuse block can be installed in the standard enclosure. For extra capacity, please refer to your local distributor or nearest Square D/Schneider Electric sales office. NOTE: Use tables and notes from page 18-20 to complete the catalog numbers. Table 18.71: Enclosed full voltage non-reversing fusible combination starters Max. Horsepower Ratings (AC3) Fuse Clip Rating 3 Phase 230 V 2 3 5 7.5 10 10 575 V 7.5 10 15 20 25 30 Amperes 30 A 30 A 30 A 30 A 60 A 60 A Fuse Clip Rating 3 Phase 230 V 2 3 5 7.5 10 10 Table 18.73: 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 Amperes 30 A 30 A 30 A 30 A 60 A 60 A 230 V 2 3 5 7.5 10 10 Table 18.74: 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Auxiliary Contacts Each Contactor 3 Phase 230 V 2 3 5 7.5 10 10 Table 18.75: 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 426. 468. 484. 500. 653. 708. Type 12/3R LE1D096B72••••• LE1D126B72••••• LE1D186B72••••• LE1D256B72••••• LE1D326C72••••• LE1D406C72••••• $ Price 551. 592. 607. 623. 829. 877. Aux. Contacts Each Contactor N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Current Rating of Contactor 9 12 18 25 32 40 Catalog Number Type 1 LE2D096B62••••• LE2D126B62••••• LE2D186B62••••• LE2D256B62••••• LE2D326C62••••• LE2D406C62••••• $ Price 712. 778. 808. 833. 1089. 1179. Catalog Number Type 12/3R LE2D096B72••••• LE2D126B72••••• LE2D186B72••••• LE2D256B72••••• LE2D326C72••••• LE2D406C72••••• $ Price 837. 915. 950. 980. 1281. 1371. Circuit Breaker Maximum Current Rating Current Rating of Contactor 15 A 15 A 30 A 30 A 50 A 50 A 9 12 18 25 32 40 Catalog Number Type 1 LE1D097D62••••• LE1D127D62••••• LE1D187E62••••• LE1D257E62••••• LE1D327F62••••• LE1D407F62••••• $ Price 569. 622. 647. 668. 870. 944. Catalog Number Type 12/3R LE1D097D7••••• LE1D127D7••••• LE1D187E7••••• LE1D257E7••••• LE1D327F7••••• LE1D407F7••••• $ Price 730. 789. 808. 834. 1088. 1179. N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Circuit Breaker Maximum Current Rating Current Rating of Contactor 15 A 15 A 30 A 30 A 50 A 50 A 9 12 18 25 32 40 Catalog Number Type 1 LE2D097D62••••• LE2D127D62••••• LE2D187E62••••• LE2D257E62••••• LE2D327F62••••• LE2D407F62••••• $ Price 836. 944. 1010. 1075. 1403. 1522. Catalog Number Type 12/3R LE2D097D72••••• LE2D127D72••••• LE2D187E72••••• LE2D257E72••••• LE2D327F72••••• LE2D407F72••••• $ Price 972. 1096. 1174. 1251. 1631. 1770. Enclosed full voltage non-reversing non-fused combination starters Max. Horsepower Ratings (AC3) 3 Phase 230 V 2 3 5 7.5 10 10 Table 18.76: 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 Fuse Clip Rating Amperes 30 A 30 A 30 A 30 A 60 A 60 A UL Class CC CC J J J J Auxiliary Contacts N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Current Rating of Contactor 9 12 18 25 32 40 Catalog Number Type 1 LE1D096A62••••• LE1D126A62••••• LE1D186A62••••• LE1D256A62••••• LE1D326A62••••• LE1D406A62••••• $ Price 416. 458. 474. 490. 643. 698. Catalog Number Type 12/3R LE1D096A72••••• LE1D126A72••••• LE1D186A72••••• LE1D256A72••••• LE1D326A72••••• LE1D406A72••••• $ Price 541. 532. 597. 613. 819. 867. Enclosed full voltage reversing non-fused combination starters Max. Horsepower Ratings (AC3) 3 Phase 200 V 2 3 5 7.5 10 10 9 12 18 25 32 40 Type 1 LE1D096B62••••• LE1D126B62••••• LE1D186B62••••• LE1D256B62••••• LE1D326C62••••• LE1D406C62••••• Enclosed full voltage reversing circuit breaker combination starters Max. Horsepower Ratings (AC3) 200 V 2 3 5 7.5 10 10 UL Class CC CC J J J J Auxiliary Contacts 3 Phase 200 V 2 3 5 7.5 10 10 N.C. 1 1 1 1 1 1 Catalog Number Enclosed full voltage non-reversing circuit breaker combination starters Max. Horsepower Ratings (AC3) 200 V 2 3 5 7.5 10 10 N.O. 1 1 1 1 1 1 $ Price Enclosed full voltage reversing fusible combination starters Max. Horsepower Ratings (AC3) 200 V 2 3 5 7.5 10 10 UL Class CC CC J J J J Catalog Number 230 V 2 3 5 7.5 10 10 460 V 5 7.5 10 15 20 30 575 V 7.5 10 15 20 25 30 Fuse Clip Rating Amperes 30 A 30 A 30 A 30 A 60 A 60 A UL Class CC CC J J J J Aux. Contacts Each Contactor N.O. 1 1 1 1 1 1 N.C. 1 1 1 1 1 1 Current Rating of Contactor 9 12 18 25 32 40 Catalog Number Type 1 LE2D096A62••••• LE2D126A62••••• LE2D186A62••••• LE2D256A62••••• LE2D326A62••••• LE2D406A62••••• $ Price 702. 768. 798. 823. 1079. 1169. Catalog Number Type 12/3R LE2D096A72••••• LE2D126A72••••• LE2D186A72••••• LE2D256A72••••• LE2D326A72••••• LE2D406A72••••• $ Price 827. 905. 940. 970. 1271. 1361. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-48 © 2007 Schneider Electric All Rights Reserved I11 Discount Schedule IEC CONTACTORS AND STARTERS Table 18.72: 460 V 5 7.5 10 15 20 30 Current Rating of Contactor 18-21 18 200 V 2 3 5 7.5 10 10 Auxiliary Contacts Enclosed Combination Starters Enclosure Modifications/Insta-Kits™/Overload Relay Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Factory Modifications and INSTA-KITS™ selection L1 Add the Factory Modification Code to the end of the catalog number created from pages 18-20 and 18-21. With the use of INSTA-KITS™, only one operator scheme is allowed. Only the combinations of operators and pilot lights shown below can be ordered. L2 START STOP 1 23 4 A 13 OLR 95 96 B Pilot lights will be at the coil voltage indicated in the catalog number for the starter. M Table 18.77: 14 Start/Stop L1 ON X1 X2 OLR B 95 96 PL 1 23 4 A 61 M 62 X1 X2 PL 18 On-Off Selector Switch L1 L2 OFF X1 IEC CONTACTORS AND STARTERS HAND AUTO 3 4 3 PL X2 95 96 M 4 61 62 X1 PL X2 Remote by Customer Connection HOA Selector Switch L1 L2 L3 13 B M A 14 98 96 97 95 $ Price Insta-Kits (for field installation) $ Price Control Units Only For-rev-stop Push Button A06L 131. LA9CA06LT 71.00 Start/Stop Push Button A06G 65. LA9CA06GT 32.80 I/O (Start/Stop) Push Button N/A — N/A — I/O Push Button (double touch) A06I 83. LA9CA06IO 41.50 Emergency Stop N/A — N/A — Hand-Off-Auto Selector Switch A06E 65. LA9CA06ET 32.80 On/off Selector Switch A06D 65. LA9CA06DT 41.50 Start/Mushroom Head Stop Push Button A06X 65. LA9CA06XT 63.00 Pilot Lights only LED Pilot light, 24, 120 or 240 V A16S 134. LA9CA16STd 66.00 Green-Red Pilot light, Direct supply, 24 or 120 V b A06S 112. LA9CA06STd 62.00 Green-Red Transformer Pilot Light, 120, 208/240, 480 A06F 207. LA9CA06FTd 113.00 or 600 V b Available combination of control units and pilot lights Hand-Off-Auto Selector Switch w/24, 120 or 240 V A16U 213. LA9CA16UTd 177.00 LED Pilot Light Start/Stop Push Button w/ 24, 120 or 240 V LED Pilot A16V 213. LA9CA16VTd 177.00 Light On/off Selector w/ 24, 120 or 240 V LED Pilot Light A16W 213. LA9CA16WTd 177.00 Start/Stop Push Button w/ Green-Red Transformer A06N 177. LA9CA06NTd 95.00 Pilot Light Start/Stop Push Button w/Green-Red Pilot Light A06V 177. LA9CA06VT 95.00 Hand-Off-Auto Selector Switch w/Green-Red Pilot A06U 273. LA9CA06UT 97.00 Light Hand-Off-Auto Selector Switch w/Green-Red 147.00 A06J 273. LA9CA06JTd Transformer Pilot Light On/off Selector w/Green-Red Pilot Light A06W 177. LA9CA06WT 95.00 On/off Selector w/Green-Red Transformer Pilot Light A06H 273. LA9CA06HTd 147.00 Control Power Transformer Standard VA, 2 fuses in Primary, 1 Fuse in secondary A206P 260. c — 50 VA extra, 2 fuses in Primary, 1 Fuse in secondary A207P 456. c — 100 VA extra, 2 fuses in Primary, 1 Fuse in secondary A208P 634. c — a Add these forms to the catalog number selected on pages 18-20 or 18-21. The numbers as shown are for use in NEMA 1 Enclosures. For uses in NEMA 12/3R change the 6 to a 7 (ex A06U becomes A07U). Price remains the same. The change DOES NOT apply to control power transformer forms. b Pilot lights are wired such that the light is on when the contactor is energized. For non-LED type pilot lights, a green lens is installed on the unit when shipped. A red lens is included for use as applicable. c Select Insta-Kits™ from table below. L2 OFF Factory Modification Codea Description Table 18.78: T1 T2 T3 D-Line AC Magnetic Starter 2-3 Pooxle d Total VA Insta-Kits™ Catalog Number $ Price 50 LA9TFD32d 140.00 100 LA9TFD80d 246.00 150 LA9TFD25d 343.00 Complete the part number for the Insta-Kits™ by selecting the voltage code from the appropriate tables below. Table 18.79: L1 L2 L3 21 + 21 B F A + B R A 24 120 208/240 480 600 Code B G M T X Table 18.80: 95 98 96 + 120 208 Secondary Voltage Code 97 Voltage Codes for control power transformers Primary Voltage 22 + 22 Voltage Codes for pilot lights Voltage (Vac) 240 480 600 208 240 24 E D C 480 600 T X 120 B A L M "C" T1 T2 T3 D-Line AC Magnetic Reversing Starter 3-Pole 18-22 I11 Discount Schedule Modified 4/16/09 © 2007 Schneider Electric All Rights Reserved Contactors TeSys™ K-Line 3-Pole Non-Reversing Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION 3-Pole Non-Reversing Mini-Contactors AC operating coils Maximum Horsepower Ratings 1Ø Maximum Current Inductive Resistive AC3 AC1 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp Amperes Amperes 0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 0.5 1.5 2 3 5 5 9 20 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp Table 18.82: Auxiliary Contacts Type of Connection Catalog Number $ Price N.O. N.C. 1 — — LC1K0610 a b 57. 1 — 1 — 1 — 1 — 1 LC1K0601 ab LC1K0910 ab LC1K0901 ab LC1K1210 ab LC1K1201 ab 57. 75. 75. 86. 86. Coil voltage codes for AC contactors Up to and including 240 V coil with integral suppression device available. Add 2 to the code required. Example J72. Price adder $10.00. Volts AC 50/60 Hz 12 24 42 48 110 120 127 200/ 208 220/ 230 230 230/ 240 277 380/ 400 400/ 415 440 480 660/ 690 Code J7 B7 D7 E7 F7 G7 FC7 L7 M7 P7 U7 UE7 Q7 N7 R7 T7 Y7 Table 18.83: DC operating coils 0.5 1.5 1.5 1.5 3 3 6 15 Screw-clamp 0.5 1.5 2 3 5 5 9 20 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp Table 18.84: LP1K0610 1 — 1 — 1 — LP1K0610 ab LP1K0601 ab LP1K0910 ab LP1K0901 ab LP1K1210 ab LP1K1201 ab — 1 — 1 — 1 75. 75. 92. 92. 106. 106. Coil voltage codes for DC contactors Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price adder $10.00. Volts DC 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD 18 LC1K0610G7 3Ø , Table 18.85: 1.5 1.5 1.5 3 3 6 15 Screw-clamp 0.5 1.5 2 3 5 5 9 20 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp Table 18.86: LP4K06105● a b 1 — 1 — 1 — — 1 — 1 — 1 LP4K0610 LP4K0601 LP4K0910 LP4K0901 LP4K1210 LP4K1201 ab ab ab ab ab ab 92. 92. 110. 110. 126. 126. Coil voltage codes for DC contactors—Low consumption Volts DC 12 24 48 72 Code JW3 BW3 EW3 SW3 For K-Line contactors with spring terminal clamps, add a “3” before the coil voltage code. For K-Line contactors with solder pin terminals, add a “5” before the coil voltage code. For K-Line contactors with slip-on terminals, add a “7” before the coil voltage code. Complete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7. Table 18.87: LR2K0316 DC–Low consumption operating coils (devices have built-in transient suppression) 0.5 Overload relays for 3-Pole contactors with screw-clamp terminals Class 10, Relay setting range–A Catalog Number 0.1 to 0.16 0.16 to 0.23 0.23 to 0.36 0.36 to 0.54 0.54 to 0.8 0.8 to 1.2 1.2 to 1.8 1.8 to 2.6 2.6 to 3.7 3.8 to 5.5 5.5 to 8 8 to 11.5 10 to 14 LR2K0301 LR2K0302 LR2K0303 LR2K0304 LR2K0305 LR2K0306 LR2K0307 LR2K0308 LR2K0310 LR2K0312 LR2K0314 LR2K0316 LR2K0321 $ Price 59. 59. 59. 59. 59. 59. 59. 59. 59. 59. 59. 59. 59. LR2K overload relays: • • • • • • AC or DC protection Ambient compensated bimetallic Class 10 Single phase sensitivity Manual or auto reset Full load current dial Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-26 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-49 © 2007 Schneider Electric All Rights Reserved I11 Discount Schedule IEC CONTACTORS AND STARTERS Table 18.81: 18-23 Contactors TeSys™ K-Line 3-Pole Reversing Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION 3-Pole Reversing Mini-Contactors Table 18.88: AC operating coils Maximum Horsepower Ratings 1Ø Maximum Current 3Ø 115V hp 230V hp 200V hp 230V hp 460V hp 575V hp 0.5 1.5 1.5 1.5 3 3 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5 Inductive Resistive AC3 AC1 A A Auxiliary Contacts Type of Connection 6 15 Screw-clamp 5 9 20 Screw-clamp 10 12 20 Screw-clamp N.C. 1 — 1 — 1 — — 1 — 1 — 1 LC2K09107 Table 18.89: Volts AC 50/60 Hz Code 18 Table 18.90: 12 24 42 48 110 120 127 J7 B7 D7 E7 F7 G7 FC7 IEC CONTACTORS AND STARTERS 1.5 1.5 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5 200/2 08 L7 220/ 230 M7 230 P7 3 3 6 15 Screw-clamp 5 9 20 Screw-clamp 10 12 20 Screw-clamp UE7 380/ 400 Q7 400/ 415 N7 440 480 R7 T7 1 — 1 — 1 — LP2K0610 ab LP2K0601 ab LP2K0910 ab LP2K0901 ab LP2K1210 ab LP2K1201 ab — 1 — 1 — 1 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD 660/ 690 Y7 167. 167. 202. 202. 232. 232. DC–Low Consumption Operating Coils (devices have built-in transient suppression) 1.5 1.5 1.5 3 3 6 15 Screw-clamp 0.5 1.5 2 3 5 5 9 20 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 1 — 1 — 1 — — 1 — 1 — 1 LP5K0610 ab LP5K0601 ab LP5K0910 ab LP5K0901 ab LP5K1210 ab LP5K1201 ab 202. 202. 238. 238. 274. 274. Coil voltage codes for DC contactors—Low consumption Volts DC Code b 277 Code Table 18.93: 130. 130. 167. 167. 191. 191. Coil voltage codes for DC contactors Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price adder $20.00. 0.5 a 230/ 240 U7 Volts DC Table 18.92: LP2K09105 LC2K0610 ab LC2K0601 ab LC2K0910 ab LC2K0901 ab LC2K1210 ab LC2K1201 ab DC operating coils 1.5 LP2K0910 $ Price Coil voltage codes for AC contactors Up to and including 240 V coil with integral suppression device available. Add 2 to the code required. Example J72. Price adder $20.00. 0.5 Table 18.91: Catalog Number N.O. 12 JW3 24 BW3 48 EW3 72 SW3 For K-Line contactors with spring terminal clamps, add a “3” before the coil voltage code. For K-Line contactors with solder pin terminals, add a “5” before the coil voltage code. For K-Line contactors with slip-on terminals, add a “7” before the coil voltage code. Complete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7. Overload Relays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-23 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-26 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-49 18-24 I11 Discount Schedule © 2007 Schneider Electric All Rights Reserved Contactors TeSys™ K-Line 4-Pole Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.94: AC Operating Coils Maximum Horsepower Ratings 1 PH 115 V hp Maximum Current 3 PH 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp Inductive Resistive AC3 AC1 A A Type of Connection Power Poles Catalog Number $ Price N.O. N.C. — 2 — 2 LC1K09004 ab LC1K09008 ab LC1K12004 ab LC1K12008 ab 75. 81. 86. 93. — — LC2K09004 ab LC2K12004 ab 167. 191. 4-Pole Mini Contactor LC2K090045 0.5 1.5 2 3 5 5 9 15 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 4 2 4 2 4-Pole Mechanically Interlocked Contactors 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5 5 10 9 12 20 20 Screw-clamp Screw-clamp 4 4 Table 18.95: Coil voltage codes for AC contactors Up to and including 240 V coil with integral suppression device available. Add 2 to the code required. Example J72. Price adder $10.00 ($20.00 for mechanically interlocked contactors) Volts AC 50/60 Hz 12 24 42 48 110 120 127 Code J7 B7 D7 E7 F7 G7 FC7 Table 18.96: 200/208 220/230 L7 M7 230 230/ 240 277 P7 U7 UE7 380/400 400/415 Q7 N7 440 480 660/690 R7 T7 Y7 DC operating coils Screw-clamp 4 2 4 2 — 2 — 2 LP1K09004 LP1K09008 LP1K12004 LP1K12008 ab ab ab ab 92. 98. 106. 113. Screw-clamp Screw-clamp 4 4 — — LP2K09004 ab LP2K12004 ab 202. 232. 0.5 1.5 2 3 5 5 9 15 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 4-Pole Mechanically Interlocked Contactors 0.5 1.5 2 3 5 0.5 1.5 3 3 7.5 5 10 9 12 20 20 Coil voltage codes for DC contactors Coil with integral suppression device available. Add 3 to the code required. Example JD3. Price adder $10.00 ($20.00 for mechanically interlocked contactors) Volts DC 12 20 24 36 48 60 72 100 110 125 200 220 230 240 250 Code JD ZD BD CD ED ND SD KD FD GD LD MD MPD MUD UD Table 18.98: DC–Low consumption operating coils (devices have built-in transient suppression) 4-Pole Mini Contactor Screw-clamp 4 2 4 2 — 2 — 2 LP4K09004 LP4K09008 LP4K12004 LP4K12008 ab ab ab ab 110. 116. 126. 134. LP5K09004 ab LP5K12004 ab 274. 0.5 1.5 2 3 5 5 9 15 Screw-clamp 0.5 1.5 3 3 7.5 10 12 20 4-Pole Mechanically Interlocked Contactors 0.5 1.5 2 3 5 5 9 20 Screw-clamp 4 — 0.5 1.5 3 3 7.5 10 12 20 Screw-clamp 4 — Table 18.99: a b 238. Coil voltages for DC contactors—Low consumption Volts DC 12 24 48 72 Code JW3 BW3 EW3 SW3 For K-Line contactors with spring terminal clamps, add a “3” before the coil voltage code. For K-Line contactors with solder pin terminals, add a “5” before the coil voltage code. For K-Line contactors with slip-on terminals, add a “7” before the coil voltage code. Complete the catalog number with the appropriate coil voltage code. For example: LC1K0610G7. Overload Relays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-23 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-26 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-49 © 2007 Schneider Electric All Rights Reserved I11 Discount Schedule 18-25 18 Table 18.97: IEC CONTACTORS AND STARTERS 4-Pole Mini Contactor Contactors and Accessories TeSys™ K-Line Contactors and Accessories Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.100: Instantaneous auxiliary contact blocks Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors. Auxiliary Contacts Type of connection LA1KN11 18 a N.O. 2 — 1 4 Screw clamp 3 2 1 — 2 — 1 4 Slip-on 1 x .250" or 2 x .110" 3 2 1 — Block of 4 contacts cannot be used with LP4K or LP5K contactors. Catalog Number N.C. — 2 1 — 1 2 3 4 — 2 1 — 1 2 3 4 $ Price LA1KN20 LA1KN02 LA1KN11 LA1KN40 a LA1KN31 a LA1KN22 a LA1KN13 a LA1KN04 a LA1KN207 LA1KN027 LA1KN117 LA1KN407 a LA1KN317 a LA1KN227 a LA1KN137a LA1KN047 a 14.20 14.20 14.20 27.30 27.30 27.30 27.30 27.30 14.20 14.20 14.20 27.30 27.30 27.30 27.30 27.30 Table 18.101: Electronic time delay auxiliary contact blocks Clip-on front mounting, 1 block per contactor and 2 blocks per pair of mechanically interlocked contactors. IEC CONTACTORS AND STARTERS LA1KN22 Timing Range Catalog Contacts (S) Number 24 to 48 Vac or Vdc On-delay 1 to 30 SPDT LA2KT2E 110 to 240 Vac On-delay 1 to 30 SPDT LA2KT2U Note: Relay outputs, with single pole double throw, 240 Vac/dc, 2 A max. Note: Operating temperature: -10 to + 60°C (14 to 140°F) Note: Control voltage, from 0.85 to 1.1 Uc. Note: Reset time: 1.5 s during time delay, 0.5 after time delay Note: Maximum switching capacity 250 VA / 150 W Voltage (V) Type $ Price 32.80 32.80 Table 18.102: Suppressor Module with incorporated LED indicator Clip-on front mounting Voltage range LA2KT2U Type 12 to 24 Vac and dc Varistor 32 to 48 Vac and dc Varistor 50 to 129 Vac and dc Varistor 130 to 250 Vac and dc Varistor 12 to 24 Vdc Diode + Zener 32 to 48 Vdc Diode + Zener 220 to 250 Vac RC b Protection by limitation of the transient voltage to 2 Uc maximum. Maximum reduction of the transient voltage peaks. Slight time delay on drop-out (1.1 to 1.5 times normal). c No overvoltage or oscillation frequency. Polarized component. Slight time delay on drop-out (1.1 to 1.5 times normal). d Protection by limitation of the transient voltage to 3 Uc maximum and limitation of the oscillation frequency. Slight time delay on drop-out (1.2 times normal). Table 18.103: Paralleling Links Description For 2 poles with screw-clamp terminals For 4 poles with screw-clamp terminals Sold in lots of 4 2 Catalog Number LA9E01 LA9E02 $ Price each 2.20 3.50 Sold in lots of Catalog Number 5 5 5 5 5 5 5 LA4KE1B b LA4KE1E b LA4KE1FC b LA4KE1UG b LA4KC1B c LA4KC1E c LA4KA1U d $ Price each 9.80 9.80 9.80 9.80 9.80 9.80 9.80 Table 18.104: Power Connectors Description Sold in lots of Catalog Number $ Price each Set of 6 power connections for reversing contactors with screw-clamp terminals Set of 4 power connections for changeover contactors with screw-clamp terminals 100 LA9K0969 0.06 100 LA9K0970 6.20 Table 18.105: Marking strips Description Clips onto front of the contactor Sold in lots of 100 Catalog Number LA9D90 $ Price each .06 Table 18.106: Accessories for overload relays LA4KE1U 18-26 Description Terminal block for separate clip-on mounting of the overload relay onto 35 mm omega rail (AM1DP200) I11 Discount Schedule Modified 4/16/09 Type of Connection Catalog Number Screw-clamp LA7K0064 $ Price 11.90 © 2007 Schneider Electric All Rights Reserved Starters TeSys™ U-Line Motor Starters Selection Process Refer to Catalog 8502CT0201 www.us.schneider-electric.com FOR CURRENT INFORMATION Step 5. Accessories (Line phase barrier LU9SP0) Step 1. Power Bases (required; select one) Step 5. Power Base Accessories Step 2. Control Units (required; select one) (optional) Advanced unit Class 10, 1-phase Class 10, 3-phase Class 20, 3-phase Self-protected base Control circuit contact block For use only with self-protected base. (LUA8E20) Multifunction, programmable unit Class 5 through Class 30 IEC CONTACTORS AND STARTERS Standard unit Class 10, 3-phase Step 3. Function Modules 18 (optional; select one) Parallel wiring, communication, and auxiliary contact modules Can be used with any control unit. Available modules are: LUFC00, ASILUFC5, LULC031, and LUFNt (shown). Starter base Fault differentiation modules Can be used with advanced control unit only. Available modules are: LUFDH20 and LUFDA10 (shown). Load Indication modules Can be used with either advanced or multifunction control units. LUFV2 Step 4. Auxiliary Contact Blocks (optional) Auxiliary contact block Can be used with any control unit. LUA1t shown. Configuring a U-Line Motor Starter 1. 2. 3. Select a power base (required) from the tables on page 18-28. Blanking covers are supplied with each power base to cover the control unit, function module, and auxiliary contact block cavities. Select a control unit (required) from the tables on page 18-28. Select a function module (optional) from the tables on page 18-29. 4. Select one or more function module accessories (optional) from the table on page 18-29 and 18-30. Accessories not shown on this page include: — — — 5. Reversing block Plug-in terminal block Control circuit pre-wiring block Select one or more power base accessories (optional) from the table on page 18-31. Accessories not shown on this page include: — — Current limiter/isolation module Communication module Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-50 © 2007 Schneider Electric All Rights Reserved 18-27 Motor Starters TeSys™ U-Line Power Bases Refer to Catalog 8502CT0201 www.us.schneider-electric.com FOR CURRENT INFORMATION 1. Power Bases The U-Line motor starter consists of one power base (selected from this page), one control unit (selected from this page), and any optional accessories (selected from pages 18-29 through 18-31). Each base includes one N.O. and one N.C. auxiliary contact to indicate the open or closed position of the power contacts. Power base accessories can be found on page 18-31. NOTE: For use as a self-protected combination starter (UL508E), incoming line phase barrier (LU9SP0) must be used. Table 18.107: Full Voltage, Non-Reversing for Standard Applications LUB32 Control Connection Max. Current (Amps) With screw terminations 12 32 Three Phase (HP max.) Single Phase (HP max.) 200/208 V 220/240 V 460 V 575/600 V 120 V 240 V 3 10 3 10 7.5 20 10 25 1.5 2 2 5 Self-Protected Starter Base Catalog Number LUB12 LUB32 $ Price 164.00 230.00 Starter Base New! Catalog Number LUS12 LUS32 $ Price 94.00 127.00 Table 18.108: Full Voltage, Reversing for Standard Applications 18 Control Connection Three Phase (HP max.) Max. Current (Amps) Single Phase (HP max.) Self-Protected Starter Base Starter Base IEC CONTACTORS AND STARTERS Catalog Catalog 200/208 V 220/240 V 460 V 575/600 V 120 V 240 V $ Price $ Price Number Number 12 3 3 7.5 10 1.5 2 LU2B12 b 325.00 a — With screw terminations 32 10 10 20 25 2 5 LU2B32 b 480.00 a — a Reversing motor starters are not available as assembled units. Order a full voltage, non-reversing motor starter base (LUS12• or LUS32•) from the tables above and a reversing block (LU6MB0• or LU2MB0•) from page 18-30. b Complete the catalog number by selecting the proper voltage code from the table below. For example: LU2B12FU. Table 18.109: Voltage Codes Volts DC AC DC or AC c d e 24 BLdc B — 48–72 — — ESe 110–240 — — FU Voltage code to use for a power base with a communication module. DC voltage with range of 0.90 to 1.10 of nominal. 48–72 Vdc; 48 Vac 2. Control Units LU2B• 2 The control units contain solid state overload relay and control power source for the U-line motor starters. When used with a U-Line power base, these create a complete self-protected motor starter. Select one control unit from the listings below based on the functions required and the full load current of the motor. NOTE: The LUC•18 and LUC•32• control units can only be used on a 32 A power base. Mechanical interference prevents the use of these devices in 12 A power bases. Definitions: • • • Standard units provide no network communication Advanced units allow control and communication via network with set features Multifunction units allow fully programmable parameters, network control and communication Table 18.110: LUCB• LUCC• LUCD• Standard Advanced Advanced Advanced Setting Range 3-phase $ Price 3-phase $ Price single-phase $ Price 3-phase (Amps) Class 10 trip fi Class 10 trip f Class 10 trip f Class 20 trip f 0.15–0.6 LUCAX6•• 80.00 LUCBX6•• 100.00 LUCCX6•• 100.00 LUCDX6•• 80.00 LUCB1X•• 100.00 LUCC1X•• 100.00 LUCD1X•• 0.3–1.4 LUCA1X•• 1.25–5.0 LUCA05•• 80.00 LUCB05•• 100.00 LUCC05•• 100.00 LUCD05•• 3–12 LUCA12•• 80.00 LUCB12•• 100.00 LUCC12•• 100.00 LUCD12•• 80.00 LUCB18•• 100.00 LUCC18•• 100.00 LUCD18•• 4.5–18 h LUCA18•• 8–32 h LUCA32•• 80.00 LUCB32•• 100.00 LUCC32•• 100.00 LUCD32•• f Complete catalog number by adding appropriate code from voltage code table above. For example: LUCAX6FU. g Multifunction units available only in 24 Vdc. h Control units for 4.5–18 and 8–32 can be used ONLY with 32 amp rated power bases (LUB32/LU2B32). i Standard unit is hand reset only. Multifunction $ Price programmable g 100.00 LUCMX6BL 100.00 LUCM1XBL 100.00 LUCM05BL 100.00 LUCM12BL 100.00 LUCM18BL 100.00 LUCM32BL $ Price 410.00 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-29 to 18-31 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-50 LUCM• 18-28 I11 Discount Schedule Modified 4/16/09 © 2007 Schneider Electric All Rights Reserved Motor Starters TeSys™ U-Line Function Modules Refer to Catalog 8502CT0201 www.us.schneider-electric.com FOR CURRENT INFORMATION 3. Function Modules The function modules available for U-Line motor starters are shown in the tables below. Only one function module can be installed in a U-line motor starter. Table 18.111: Available Function Modules Motor load indication LUFV• Provides indication between an overload trip Advanced control units only and a short circuit trip.a 24–250 Vac or Vdc (power from control unit) Signals when the motor current reaches 1.05 of the full load setting on the control unit. Provides a signal proportional to the average currents in the three phases divided by the full load current setting of the control unit. The output corresponds to a load status of 0–2 times the full load setting of the control unit. Provides a convenient way to reduce control wiring and allow for connecting starters to a communications network by providing 24 Vdc for the starters. Advanced control units only 24–250 Vac or Vdc (power from control unit) Advanced or multi-function control units 4–20 mA (requires separate 24 Vdc power supply) Catalog Number $ Price LUFDH20 104. LUFDA10 104. LUFW10 104. LUFV2 125. Advanced or multi-function control units(24 Vdc only) and LU9G02 LUFC00 38. LU9BN11C or LU9MRC pre- splitter box and PLC network wired connector Advanced or multi-function Allows the U-Line starter to be connected control units (24 Vdc only) Requires separate 24 Vdc AS-i communication 125. directly to the network using AS-i protocols. and LU9BN11C or LU9MRC power supply and AS-i network ASILUFC5 pre-wired connector Advanced or multi-function Allows the U-Line starter to be connected control units (24 Vdc only) Requires separate 24 Vdc AS-i2 communication 125. directly to the network using AS-i2 protocols. and LU9BN11C or LU9MRC power supply and AS-i2 network ASILUFC51 pre-wired connector Advanced or multi-function Allows the U-Line starter to be connected control units (24 Vdc only) Requires separate 24 Vdc LULC033 145. Modbus® communication directly to the network using and LU9BN11C or LU9MRC power supply Modbus protocols. pre-wired connector Advanced or multi-function Advantys STB Allows the U-Line starter to be connected to control units (24 Vdc only) Requires separate 24 Vdc LULC15 145. Communication the network using the Advantsys STB protocol and LU9BN11C or LU9MRC power supply pre-wired connector Advanced or multi-function Can Open Allows the U-Line starter to be connected to control units (24 Vdc only) Requires separate 24 Vdc LULC08 145. Communication the network using the Can Open protocol and LU9BN11C or LU9MRC power supply pre-wired connector Advanced or multi-function the U-Line starter to be connected to control units (24 Vdc only) Requires separate 24 Vdc Beckoff Communication Allows LULC14 145. the network using the Beckoff protocol and LU9BN11C or LU9MRC power supply pre-wired connector Advanced or multi-function the U-Line starter to be connected to control units (24 Vdc only) Requires separate 24 Vdc Profibus Communication Allows LULC07 145. the network using the Profibus protocol and LU9BN11C or LU9MRC power supply pre-wired connector Advanced or multi-function Device Net Allows the U-Line starter to be connected to control units (24 Vdc only) Requires separate 24 Vdc LULC09 145. Communication the network using the Device Net protocol and LU9BN11C or LU9MRC power supply pre-wired connector a On a short circuit trip, the function module contact changes state, the operating handle moves to the "Trip" position, and the power poles open. On thermal overload (and all other faults), the function module contact changes state. In Auto Reset mode, the operating handle remains in the "Ready” position and the power poles open. After a motor cool-down period (or after the fault is corrected) the unit resets and the power poles close. In Manual Reset mode, the operating handle moves to the "Trip" position and the power poles open. After a motor cool-down period (or after the fault is corrected) the handle must be moved to the "Reset" position and then to the "Ready" position. Parallel wiring LUFD• Operation Requirements For use with: These function modules provide hard contacts to indicate Various operating conditions of the U-Line starter. Units with screw terminals plug directly into the U-Line power base. Units without terminals require the appropriate terminal block to be installed. Table 18.112: 3. Auxiliary Contact Function Modules LUFN• © 2007 Schneider Electric All Rights Reserved Contact Arrangement 2 N.O. 1 N.O. and 1 N.C. 2 N.C. Catalog Number LUFN20 LUFN11 LUFN02 I11 $ Price 23. Discount Schedule 18-29 IEC CONTACTORS AND STARTERS Fault differentiation with manual reset (thermal overload) Fault differentiation with auto reset Thermal overload pre-alarm Description 18 Module Motor Starters TeSys™ U-Line Auxiliary Contact Blocks, Reversing Blocks and Accessories www.us.schneider-electric.com FOR CURRENT INFORMATION Refer to Catalog 8502CT0201 4. Auxiliary Contact Blocks Table 18.113: Contact State for Each Modea Contact Indicates Terminals LU2Bk Contact Normal Status Off Ready Run Short Circuit Trip Overload Trip (Manual Reset) Overload Trip (Remote/ Auto Reset)b I I I O Ready condition N.O. O I I O O Fault condition N.C. I I I O O Ready condition N.O. O I I O O Screw Fault condition N.O. O O O I I a I–indicates closed contact; O–indicates open contact b Requires multifunction or advanced control unit plus fault differentiation module LUFDDA10. Screw Catalog Number $ Price LUA1C11 23. LUA1C20 Table 18.114: Additional Accessories LU9C1 Description LU9BN11 18 Pre-wire connector LU9C2 For use on: Power base LUB• and LUS• Power bases LUB• and LUS• to pre-wire 24 Vdc from LUFC00, ASILUFC5, or LULC031 Power bases LU2B• to pre-wire 24 Vdc from LUFC00, ASILUFC5, or LULC031 to reversing block Auxiliary contact function module cavity Auxiliary contact block cavity Control Terminal Block Blanking covers Catalog Number LU9BN11 $ Price 23. LU9BN11C 38. LU9MRC LU9C1 LU9C2 5. IEC CONTACTORS AND STARTERS Table 18.115: Reversing Blocks and Accessories LU2MB0 LU9MR1 Mounting LU9M1 Catalog Number c LU2MB0c LU6MB0c Control Connections Directly beneath power base Separate (panel or 35 mm DIN rail) $ Price Without terminals 148. Without terminals 148. Direct mounted for LUBA0•, LU2BB0•, LU2MB0•, Coil terminals LU9M1 10. or LU6MBO• Control block Separately mounted for LU6MB0• LU9MR1 10. Direct mounting of reversing block for connections Pre-wire connector between power base and connector block LU9MR1C 21. (required for direct mounting of reversing block) c Complete the catalog number by selecting the proper voltage code from the table below. For example: LU2MB0FU. LU6MB0 Table 18.116: Voltage Codes LU9MR1 Volts DC AC DC or AC 24 BL B — 48–72 — — ES 110–240 — — FU LU9M1 18-30 I11 Discount Schedule © 2007 Schneider Electric All Rights Reserved Motor Starters TeSys™ U-Line Power Base Accessories, PowerSuite Software Refer to Catalog 8502CT0201 www.us.schneider-electric.com FOR CURRENT INFORMATION New! 5. Power Base Accessories Table 18.117: Application Technical Data Mounting Catalog Number $ Price Switches control circuit power via LUB• handle (NEC430-74 compliance) Additional current limiting aspects for the starter Replacement cartridge for LUALB1 5 amp at 600 Vac 5 amp at 250 Vdc Side mounting to LUB• and LU2B• only LUA8E20 47.00 130 kA at 460 V 70 kA at 690 V 130 kA at 460 V 70 kA at 690 V Direct mounting to LUB• and LU2B• LUALB1 78.00 — LUALF1 52.00 LU9SP0 10.00 Accessory Control circuit contact block Current limiter/isolator Limiter cartridge LUALB1 Incoming line phase For UL 508 Type E barrier compliance Through-the-door operating mechanism Operating handle (NEMA 12) Direct mounting to LUB•, LU2B•, or LUALB1 — Use in enclosures 7.5 to 20 inches deep. Use with LUB• only. — — Black / Blue Red / Yellow Use with LU9AP00 Enclosure door Enclosure door LU9AP00 83.00 LU9AP11 LU9AP12 21.00 21.00 Table 18.118: PowerSuite Software and Accessories LUBk2 $ Priceb 150.00 75.00 95.00 IEC CONTACTORS AND STARTERS Itema Catalog Number PowerSuite software VW3A8104 PC connection kit VW3A8106 Pocket PC connection kit VW3A8111 a For complete details on all components included with each item, refer to Catalog #8502CT0201. b Items under Discount Schedule CP4C. Additional accessories and components are available, including: • • • • Mounting accessories Gateways Cabling accessories Magelis® remote display unit For the complete line of TeSys U-Line motor starter accessories and all technical details (specifications, wiring diagrams, etc.) pertaining to the product line, refer to Catalog 8502CT0201. Table 18.119: TeSys U-Line Controller 18 References Control bases (control circuit voltage 24 Vdc) Connection Current transformers For use with contactor Catalog Number $ Price Screw LC1D•• LC1F••• LUTM10BL LUTM20BL 200.00 200.00 For motor type 3-phase 3-phase 3-phase Setting range 0.35—1.05 0.35—1.05 0.35—1.05 Catalog Number LUCBT1BL LUCDT1BL LUCMT1BL $ Price 75.00 75.00 410.00 Catalog Number $ Price Control Screw Control units Description Advanced Multifunction Current transformers Class 10 20 5 to 30 Operating current Primary 30 50 100 200 400 800 Secondary 1 1 1 1 1 1 LUTC0301 LUTC0501 LUTC1001 LUTC2001 LUTC4001 LUTC8001 60.00 60.00 60.00 60.00 75.00 75.00 Function modules and communication modules LUT M + LUCM T1BL + LUTC •• The TeSys model U controller is compatible with the modules listed below. • • • Thermal overload alarm module LUF W10. c Motor load indication module LUF V2. Modbus communication modules LUL C032 and LUL C033. c © 2007 Schneider Electric All Rights Reserved Module LUF W10 is only compatible with control units LUCB T1BL and LUCD T1BL. I11 Discount Schedule Modified 4/17/09 18-31 Soft Starters Altistart U01 and TeSys U Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.120: Soft Start/Soft Stop Unit for 0.75 to 15 kW Motors (Can be combined with the TeSys U Starter) Motor Starter Motor Power (1) 230 V 460 V HP HP Nominal Current Part Number $ Price A 3-Phase supply voltage: 200 ... 480 V 50/60 Hz 1 2 6 ATSU01N206LT 1.5 3 2 5 9 ATSU01N209LT 3 7.5 12 ATSU01N212LT 5 10 22 ATSU01N222LT 7.5 15 10 20 32 ATSU01N232LT a Standard motor power ratings, HP power ratings indicated according to standard UL 508. 133.00 152.00 175.00 219.00 300.00 Table 18.121: Accessories Description Power connector between ATSU 01N2••LT and TeSys U ATSU01•• Used for Starter Reference $ Price ATSU01N2••T VW3G4104 10.00 18 Table 18.122: TeSys U Starter and Soft Start Unit Combinations 1 Motor Power LUBp2BL IEC CONTACTORS AND STARTERS 200 V 2 b 3 TeSys U Voltage 460 V Soft Starter Power Base Control Unit b HP HP 1 2 ATSU01N206LT LUC•05BL 1.5 3 ATSU01N206LT LUC•12BL 2 5 ATSU01N209LT LUC•12BL LUB 12 LUS 12 3 — ATSU01N212LT LUC•12BL — 7.5 ATSU01N212LT LUC •18BL 5 10 ATSU01N222LT LUC•18BL 7.5 15 ATSU01N222LT LUC•32BL LUB 32 LUS 32 10 20 ATSU01N232LT LUC•32BL Depending on the configuration of the chosen TeSys U starter, replace the • with “A” for standard, “B” for advanced, amd “M” for multifunction. See page 18-28 for a complete list of available control units. Control voltage must be 24 Vdc. LUCM ppBL Example of a starter motor combination with: • • • • 4 Non-reversing power base for DOL starting (LUB•2BL) Control unit (LUC••BL) Power connector (VW3G4104) Altistart U01 soft start/stop unit (ATSU01N2••LT) 1. U-Line Power Base 2. U-Line Control Unit 3. Power Connector between the U-line and ATS01 4. ATS01 Soft starter ATSU 01N2ppLT Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18-51 18-32 I11 Discount Schedule © 2007 Schneider Electric All Rights Reserved Starters GV2 and GV3 Manual Starter and Protector Refer to Catalog 2520CT0001 www.us.schneider-electric.com FOR CURRENT INFORMATION The GV family of products are 3-pole, horsepower rated, UL 508 listed, manual starters. They include a manual disconnect, class 10 ambient-compensated thermal overload relay, and an instantaneous magnetic trip mechanism in one compact unit. Any GV manual starter can be used alone for local manual control of a motor with individual full-load currents up to 220 amps. The GV family of products may also be used in group motor installations in accordance with National Electric Code article 430-53. Group motor installations give you greater panel density for smaller size and require fewer parts and less wiring necessary for installation when compared to conventional panel designs. The GV2P and GV3P products also have an additional UL 508 type E rating as a stand alone self-protected manual combination starter. The UL 508 type E rating requires the addition of line side insulating barrier GV2GH7 for the GV2P or part number GV3G66 for the GV3P. The GV2P and the GV3P self-protected manual combination starter may also be combined with specific size contactors from the LC1D product family for a UL 508 Type F combination starter construction. These products have UL-listed short circuit current rating from 10–100 KA depending on application size and voltage. See www.us.telemecanique.com for more information. How to Order GV2ME To order the basic motor starter, select the model number (GV2ME••, GV2P••, or GV3P••) with the appropriate thermal setting from the table below. The thermal trip range and setting should be determined from the motor nameplate fullload current. Table 18.123: Group Motor Applications 3Ø GV2/3M pushbutton GV2/3P rotary handle 115 V 230 V 200 V 230 V 460 V 575 V Max. Fuse or Catalog Catalog $ Price hp hp hp hp hp hp Circuit Breaker Number Number 0.11–0.16 — — — — — — 1200 A GV2ME01a 106. GV2P01 0.16–0.25 — — — — — — 1200 A GV2ME02a 106. GV2P02 0.25–0.40 — — — — — — 1200 A GV2ME03a 106. GV2P03 0.40–0.63 — — — — — — 1200 A GV2ME04a 120. GV2P04 0.63–1 — — — — 0.5 0.5 1200 A GV2ME05a 120. GV2P05 1–1.6 — 0.1 — — 0.75 1 1200 A GV2ME06a 120. GV2P06 1.6–2.5 — 0.667 0.5 1 1.5 1200 A GV2ME07a 120. GV2P07 0.5 2.5–4 1/8 0.333 0.75 1 2 3 1200 A GV2ME08a 120. GV2P08 4–6.3 1/4 0.5 1.5 1.5 3 5 1200 A GV2ME10a 120. GV2P10 6–10 0.5 1.5 2 3 5 7.5 1200 A GV2ME14a 120. GV2P14 9–14 0.75 2 3 3 10 10 1200 A GV2ME16a 149. GV2P16 13–18 1 3 5 5 10 15 1200 A GV2ME20a 149. GV2P20 17–23 1.5 3 5 7.5 15 20 1200 A GV2ME21a 149. GV2P21 20–25 2 3 5 7.5 15 20 1200 A GV2ME22a 149. GV2P22 24–32 2 5 10 10 20 30 1200 A GV2ME32 149. GV2P32 9–13 1 2 3 3 7.5 10 — — GV3P13 New! 12–18 1 3 5 5 10 15 — — GV3P18 17–25 2 3 7.5 7.5 15 20 — — GV3P25 23–32 2 5 10 10 20 30 — — GV3P32 30–40 3 5 10 10 30 30 — — GV3P40 37–50 3 7.5 15 15 40 40 — — GV3P50 48–65 5 10 20 20 50 50 — — GV3P65 a For spring terminals add 3 to the catalog number, for example, GV2ME013. GV2ME32 is not available with spring terminals. $ Price 141. 141. 122. 155. 155. 155. 155. 155. 155. 155. 185. 185. 185. 185. 185. 269. 269. 269. 269. 336. 336. 336. Table 18.124: Maximum Horsepower Ratings GV3P Thermal Setting (A) 12–20 15–25 25–40 30–50 48–80 60–100 90–150 132–220 GV7RE20 © 2007 Schneider Electric All Rights Reserved 1Ø GV2/3M pushbutton 3Ø GV2/3P rotary handle Toggle Operator 115 V hp 230 V hp 200 V hp 230 V hp 460 V hp 575 V hp — — — — — — — — — — — — — — — — — — — — — — — — 5 7.5 10 15 30 30 50 75 10 15 30 30 60 75 100 150 15 20 30 40 75 100 150 200 Standard Interrupt Catalog Number GV7RE20 GV7RE25 GV7RE40 GV7RE50 GV7RE80 GV7RE100 GV7RE150 GV7RE220 $ Price 417. 417. 417. 417. 417. 456. 502. 502. High Interrupt Catalog Number GV7RS20 GV7RS25 GV7RS40 GV7RS50 GV7RS80 GV7RS100 GV7RS150 GV7RS220 $ Price 542. 542. 542. 542. 542. 594. 652. 652. Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 18-36 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-34 to 18-35 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55 I11 Discount Schedule Modified 4/16/09 18-33 IEC CONTACTORS AND STARTERS GV2P21 with GV2GH7 installed 1Ø 18 Maximum Horsepower Ratings Thermal Setting (A) Starters Accessories TeSys™ GV2 and GV3 Manual Starters and Protectors Refer to Catalog 2502CT0001 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.125: Voltage Trips Only one trip or fault signaling contact can be installed per GV2/GV3 device. Characteristics Voltage Frequency Catalog Numbera $ Price 50 Hz GVA•025 24 V 60 Hz GVA•026 50 Hz GVA•055 48 V 60 Hz GVA•056 100–110 V 50/60 Hz GVA•107 50 Hz GVA•115 110–115 V 60 Hz GVA•116 120–127 V 50 Hz GVA•125 127 V 60 Hz GVA•115 Undervoltage or 200 V 50 Hz GVA•207 Voltage trips Shunt trip 200–220 V 60 Hz GVA•207 54.00 GV2 & GV3 (external mount, 50 Hz GVA•225 1 block right side only) 220–240 V 60 Hz GVA•226 50 Hz GVA•385 380–400 V 60 Hz GVA•386 415–440 V 50 Hz GVA•415 415 V 60 Hz GVA•416 440 V 60 Hz GVA•385 480 V 60 Hz GVA•415 500 V 50 Hz GVA•505 600 V 60 Hz a To order an under voltage trip: replace the bullet ( •) with a U, example: GVAU025. To order a shunt trip: replace the bullet ( •) with an S, example: GVAS025. Description GVAU116 18 IEC CONTACTORS AND STARTERS Table 18.126: Auxiliary Contact Blocks Description GVAE11 Instantaneous auxiliary contacts GV2 + GV3 Fault signaling contact + instantaneous auxiliary contact GV2 + GV3 Mounting Location Max. No. of Blocks Frontbg 1 Left Hand Side 2 Left Hand Sided 1 Contact Type Sold in lots of Catalog Number N.O. or N.C.c N.O. + N.C. N.O. + N.O. N.O. + N.C. N.O. + N.O. N.O. (fault) + N.O. N.O. (fault) + N.C. N.C. (fault) + N.O. N.C. (fault) + N.C. 1 10 1 1 1 1 1 1 1 GVAE1 GVAE11e GVAE20e GVAN11e GVAN20e GVAD1010 GVAD1001 GVAD0110 GVAD0101 14.50 23.80 23.80 23.80 23.80 36.20 36.20 36.20 36.20 GVAM11 23.80 Short circuit signaling contact Left Hand Side 1 SPDT 1 GV2 + GV3 Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P. Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted. The GVAD is always mounted next to the starter. For spring terminals add 3 to the catalog number. Example: GVAE113 One trip or one fault signaling can be fitted per GV3. Cannot be used with GV2GH7 insulator. $ Price b c d e f g Table 18.127: Voltage Trips–Technical Data (GV2AU, GV2AS) Rated Voltage–660 Vac h Model Inrush Sealed Pick-Up Voltage GVAU 12 VA / 8 W 3.5 VA / 1.1 W 0.8 to 1.1 GVAS 14 VA / 10.5 W 5 VA / 1.6 W 0.7 to 1.1 From the loss of voltage at the trip terminals to the opening of the starter contacts. Drop-Out Voltage 0.35 to 0.7 0.2 to 0.75 Operating Timeh 10 to 15 ms 10 to 15 ms GVAD0101 Table 18.128: GV3P Accessories New! Description Set of 3-pole 115 A busbars (tap-offs: 3, pitch: 64 mm) Cover “Larger Spacing” UL 508 type E (Only one cover required on supply side) IP 20 cover (Two covers required per starter) Padlocking device For use with up to 4 padlocks (not supplied) Ø 6 mm shank maximum For GV3P Catalog Number GV3P•• GV3G364 $ Price 30.00 GV3P•• GV3G66 12.00 GV3P•• LAD96570 8.00 GV3P•• GV3P••• GV2V03 130.00 GVAN11 18-34 CP10 I11 Discount Schedule Modified 4/16/09 © 2007 Schneider Electric All Rights Reserved Starters Accessories TeSys™ GV7 Manual Starters and Protectors Refer to Catalog 2502CT0001 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.129: Auxiliary contact blocks (auxiliary contact functions depends on location inside the device) Description Standard Instantaneous Trip Indication Fault Indication Low Level Instantaneous Trip Indication Fault Indication Max. No. of Blocks Contact Type Catalog Number $ Price Inside Device 2 per device 1 per device 1 per device N.O. + N.C. N.O. + N.C. N.O. + N.C. GV7AE11 23.80 Inside Device 2 per device 1 per device 1 per device N.O. + N.C. N.O. + N.C. N.O. + N.C. GV7AB11 23.80 Table 18.130: Voltage Trips Mounting Location Max. No. of Blocks Undervoltage Trip Inside Device 1 per device Shunt Trip Inside Device 1 per device Fault Indication Inside Device 1 per device Voltage 48 Vac 110–130 Vac 200–240 Vac 380–440/480 Vac 525 Vac 48 Vac 110–130 Vac 200–240 Vac 380–440/480 Vac 525 Vac 24–130 110–415 50 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50 Hz 50 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50 Hz Catalog Number GV7AU055 GV7AU107 GV7AU207 GV7AU387 GV7AU525 GV7AS055 GV7AS107 GV7AS207 GV7AS387 GV7AS525 GV7AD111 GV7AD112 $ Price 64.00 64.00 72.00 Table 18.131: Wiring Accessories Description GV7RE20 Box Lugs Phase Barriers, Bus Bars & Shrouds Terminal Extension Kit Terminal Shroud Kit Phase Barriers Insulating Barriers Busbars and Covers GV7AD111 Application Sold in lots of 3 for GV7R•20–150i Sold in lots of 3 for GV7R•220i Increases center distance between phases to 45 mm Covers terminal connections for touch safe protection Provides maximum phase separation at connection points Provides insulation between connectors and backplate Connect to LC1F115–185 contactor Connect to LC1F225–265 contactor Operating Handles and Accessories Black rotary operating handle with black legend plate (mounts directly on device) Red rotary operating handle with yellow legend plate (mounts directly on device) Conversion accessory to mount device directly on panel door Black rotary operating handle with black legend plate and extension kit (185–600 mm) Red rotary operating handle with yellow legend plate and extension kit (185–600 mm) Padlocking device for toggle handle (max. 38 mm padlocks) i Wire size: GV7AC021—#14–3/0; GV7AC022—#14–350 kcmil. Catalog Number GV7AC021 GV7AC022 $ Price 13.10 each 16.60 each GV7AC03 GV7AC01 GV7AC04 GV7AC05 GV7AC06 GV7AC07 31.10 27.90 20.70 16.60 31.10 31.10 GV7AP03 GV7AP04 GV7AP05 GV7AP01 GV7AP02 GV7V01 57.00 57.00 9.30 68.00 68.00 9.30 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 18-52 to 18-55 GV7AS055 GV7AP03 © 2007 Schneider Electric All Rights Reserved GV7AC021 GV7V01 GV7AE11 I11 Discount Schedule 18-35 IEC CONTACTORS AND STARTERS Description 18 GV7AC01 Mounting Location Starters Accessories TeSys™ Manual Starters and Protectors LS1 Fuseholders Refer to Catalog 2502CT0001 www.us.schneider-electric.com FOR CURRENT INFORMATION • • • • • • 45 mm wide (same dimensions as GV2ME) Available with screw clamp and spring type terminals Mounts directly to LC1D09–D32 contactors (with use of GV2AF3 or GV2AF4) Meets application needs for fusible starter Uses GV2AE instantaneous contact blocks to open control circuits DIN rail mounted Table 18.132: Description Dimensions Fuse Type IN mm Spring terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 Screw clamp terminals, 3-pole CC, KTK-R 0.41 x 1.5 10.3 x 38 Spring terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 Screw clamp terminals, 3-pole aM, gG 0.39 x 1.5 10 x 38 Auxiliary main pole adder aM, gG 0.39 x 1.5 10 x 38 a Can be mounted on left-hand or right-hand side of the 3-pole LS1D32 block. Use In Catalog Number US Markets US Markets European Markets European Markets European Markets LS1D303 LS1D30 LS1D323 LS1D32 LA8D324a $ Price 67. 57. 67. 57. 29. Table 18.133: Specifications Type Max. voltage Max. current 18 LS1D30, LS1D303 LS1D32, LS1D323, LS1DT32 600 V 3 Phase 30 A IEC 60947-1, 60947-2, 60947-4-1, EN60204, BS4841, UL 508, CSA 222.2 No. 14, NFC 63-650, 63-120, 79-130, VDE 0113, 0660 UL, CSA BV “TH” “TH” o -58 to 158 F (-50 to +70o C) Conforming to standards LS1D30 IEC CONTACTORS AND STARTERS Product approvals Protective treatment Ambient air temperature —operation Wiring Number of conductors and cross sectional area (c.s.a.) Max. 2–#8 AWG (2–6 mm2) 2–#8 AWG (2–6 mm2) 2–#10 AWG (2–4 mm2) 0.5 J 15 in-lb (1.7 N•m) No Solid cable Flexible cable without cable end Flexible cable with cable end Resistance to mechanical impact conforming to IEC 60947-1 §7-1-6 Tightening torque Sensitivity to phase failure Min. 2–#16 (2–1 mm2) 2–#14 (2–1 mm2) 2–#16 AWB (2–1 mm2) Table 18.134: Specifications Operating Positions: File E164864 CNN NLRV 30 90 90 30 File LR81630 Class 3211 05 Rated voltage—600 V Rated thermal current—25 A (GV2), 63 A (GV3) Mechanical life: GV2: 18-36 100,000 operations I11 Discount Schedule Modified 4/16/09 Shock resistance—30 g (conforming to IEC 600 68-2-27) Vibration resistance—5 g (5 to 150 Hz) (IEC 600 68-2-26) Ambient temperature: -40 to 176oF (-40 to +80oC) for storage -4 to 140oF (-20 to +60oC) open operation -4 to 104oF (-20 to +40oC) enclosed operation Maximum operating life—25 operations per hour Operating current of magnetic trip is approximately 13 times maximum thermal trip (non-adjustable setting) © 2007 Schneider Electric All Rights Reserved Starters Accessories TeSys™ GV2 Manual Starters and Protectors Refer to Catalog 2502CT0001 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.135: GV2 Mounting Accessories Description 7.5 mm compensation plate Mounting plate For mounting GV2ME or GV2P and contactor LC1D09 thru D32 Common mounting plate Adapter plate Combination block GV2GH7 Standard Catalog Number Pack b Application For GV2 plus any 3-pole LC1D09 thru LC1D25 contactor. (supplied with GV1G02 connector) For screw mounting of GV2M Interconnect for GV2 plus any 3-pole LC1K or LP1K contactor Interconnect GV2 and LC1D09 thru D32 Interconnect GV2 and LC1D09 thru D32 mounted on LAD31 To allow mounting of GV2M and GV2P on a common bus bar 1 10 10 10 10 10 10 10 GK2AF01 GV2AF02 GV2AF01 GV2AF3 GV2AF4 GV1F03 LAD31 LAD311 $ Price Each 14.40 4.70 9.30 2.10 2.10 3.60 4.10 8.20 Table 18.136: GV2 Cabling Accessories—Bus Bars Description Application Pitch 45 54 72 45 54 45 54 72 54 For feeding 2 GV2 starters 3-Pole, 63 A Bus Bar For feeding 3 GV2 starters For feeding 4 GV2 starters For feeding 5 GV2 starters Standard Pack b 1 1 1 1 1 1 1 1 1 Catalog Number GV2G245 GV2G254 GV2G272 GV2G345 GV2G354 GV2G445 GV2G454 GV2G472 GV2G554 $ Price Each 15.50 15.50 15.50 19.10 19.10 22.80 22.80 22.80 22.80 Description Terminal blocks LAD31 Application Top feed for use with bus bars Bottom feed, to be used with bus bars; can be fitted with GV1L3 current limiter To cover unused bus bar outlets For connecting a GV2 to an LC1D09 thru D25 contactor Protective end cover 3-pole flexible connector Conduit adapter (1⁄ 2" NPT) Incoming line insulator For GV2P when used in UL 508 Type E applicationsa a Cannot be used with front-mounted auxiliary contact block. Standard Pack b Catalog Number 1 GV1G09 $ Price Each 22.70 1 GV2G05 22.80 5 10 1 10 GV1G10 GV1G02 GV2AK1 GV2GH7 2.40 9.50 10.80 10.00 Table 18.138: GV2 Other Accessories Through-Door operator - GV2P Application Front mount, 3-pole visible isolation on incoming side of GV2P Increases interrupt capacity when attached to GV2M For operating GV2P through enclosure door (red handle, yellow legend plate) For NEMA 1 use. Standard Pack b Catalog Number 1 GV2AK00 1 GV1L3 1 GV2AP02 $ Price Each 47.60 78.00 90.00 18 Description Visible isolation block - GV2P Current limiter - GV2M Table 18.139: GV2 Enclosures Description Mounting Rating NEMA 1, IP41 IP55 NEMA 1, IP41 IP55 NEMA 1, IP41 IP55 Surface mount Enclosures for GV2M with or without accessories (maximum of 1 accessory Flush mount on right and left) Enclosures are not UL or CSA listed. Flush mount reduced width (max. of 1 accessory on right) Catalog Number GV2MC01 GV2MC02 GV2MP01 GV2MP02 GV2MP03 GV2MP04 $ Price Each 36.20 52.00 20.70 36.20 18.60 33.10 Table 18.140: GV2 Enclosures Accessories Description Padlocking device for GV2M (when padlocked, starter is automatically in Off position) Type Spring return LAD311 Key release (Ronis key no. 455) Turn to Release Latching / Padlockable Turn to Release Sealing kit For enclosures GV2MC01 and GV2MP01 110 V Green 110 V Red 110 V Orange 110 V White 220/240 V Green 220/240 V Red Pilot Light (neon) 220/240 V Orange 220/240 V White 380/440 V Green 380/440 V Red 380/440 V Orange 380/440 V White b Orders must specify multiples of quantities listed. c Supplied with IP55 sealing kit. Mushroom head stop pushbutton (40 mm, red) c Latching Standard Packb Catalog Number $ Price Each 1 GV2V01 17.90 1 1 1 1 10 10 10 10 10 10 10 10 10 10 10 10 10 GV2K011 GV2K021 GV2K031 GV2K04 GV2E01 GV2SN13 GV2SN14 GV2SN15 GV2SN17 GV2SN23 GV2SN24 GV2SN25 GV2SN27 GV2SN33 GV2SN34 GV2SN35 GV2SN37 23.90 69.00 34.70 78.00 12.00 17.90 GV2AF3 / GV2AF4 © 2007 Schneider Electric All Rights Reserved I11 Discount Schedule Modified 4/16/09 IEC CONTACTORS AND STARTERS Table 18.137: GV2 Other Cabling Accessories 18-37 Wiring, Communications, and Busbar System TeSys™ Contactors and Motor Protectors with Spring Terminals www.us.schneider-electric.com FOR CURRENT INFORMATION Refer to Catalog 8502CT0101 Table 18.141: Splitter Boxes A total of up to eight starters is permissible after extensions. Use multiple quantities of the same catalog number to create the desired line-up. Description APP2R4H1 Type of Control-command Connection on Control System Side No. of I/O per Starter — — 50 A power splitter box 1 x HE10 8I/8O 1 x HE10 16I and 1 x HE10 8O 50 A power and control splitter box Catalog Number $ Price 2 4 4 4 2 4 2 4 LAD322 LAD324 APP2R4H1 APP2R4H2 APP2R2E APP2R4E APP2R2AS APP2R4AS 52.00 93.00 124.00 124.00 124.00 124.00 124.00 124.00 1I/1O 2I/1O Via module APP1C••• a — 2I/1O 1I/1O AS-i a No. of Starters per Unit Connection to an APP1C••• module via APP2CX adaptor (LAD35). Table 18.142: Power Connection Components for One Starter LAD35 18 Description Kit Consists of: Catalog Number Assembly and power connection kit One LAD31 plate for GV2ME and two LAD34 power connection modules LAD351 Reversing kit b One set of bus bars and one mechanical interlock LAD32 b To create a D-Line reverser, use two LC1D contactors, one assembly and power connection kit, and one reversing kit. $ Price 21.00 20.70 Table 18.143: Power Connection Accessories for One Starter Description IEC CONTACTORS AND STARTERS Upstream terminal block (50 A max) Downstream terminal block (50 A max) LAD3B Max. Connection Cross-Section 16 mm2 (6 AWG) 6 mm2 (10 AWG) Catalog Number LAD3B LAD331 $ Price 83.00 5.00 Table 18.144: Control Connection Module for One Starter D-Line Coil Voltage Description Control connection module (integrating contact block GVAE20) LAD33 Use Power supply for one or two power splitter boxes Connection of motor cables c d 12–240 Vac or 24–125 Vdc 24–48 Vdc Type of Coil Control Relay Electromechanical c Without relay d Type of Starter Catalog Number Non-reversing Reversing Non-reversing Reversing APP2D1 APP2D2 APP2D1D APP2D2D $ Price 41.40 72.00 31.10 31.10 Relay supplied mounted on the front panel of the control connection. The use of D-Line low consumption contactors is recommended. Table 18.145: Spare or Replacement Parts Description Type of Control-command Connection on Control System Side Plate for mounting a GV2ME manual starter No. of I/O per Starter — — Power connection module — 1 x HE10 8I/8O 1 x HE10 16I and 1 x HE10 8O — 1I/1O 2I/1O Control-command splitter box (single, for mounting on a power splitter box) Per module APP1C••• e AS-i Replacement electromechanical relay (for control connection module) e Connection to an APP1C••• module via APP2CX adaptor (LAD35). — 2I/1O 1I/1O — No. of Starters Sold in Lots of Catalog Number 1 1 1 4 4 2 4 2 4 1 10 10 10 1 1 1 1 1 1 10 LAD31 LAD311 LAD341 APP2R4H3 APP2R4H4 APP2R2C APP2R4C APP2R2A APP2R4A APP2ER $ Price 4.10 8.20 5.00 75.00 75.00 75.00 75.00 75.00 75.00 5.00 APP2D1• 18-38 I11 Discount Schedule Modified 4/17/09 © 2007 Schneider Electric All Rights Reserved Busbar Accessories TeSys™ AK5 Panel Busbar System Refer to Catalog 8502CT0101 www.us.schneider-electric.com FOR CURRENT INFORMATION The AK5 pre-fabricated bus bar system provides a quick and easy method of mounting control devices. All components are finger safe, UL Listed, CSA approved and CE marked. Although the AK5 system can be screw mounted onto any type of support, it must be mounted on the AM1DL201 DIN rail when component mounting plates incorporating a tapoff are used. When using tap-offs, the nominal operating current of the bus bar (160 Amperes @ 35o) must not be exceeded. AK5JB143 Table 18.146: 160 Ampere Three Phase Busbar System Maximum number of mounting plates Tap-off IN 1.42 a IN 36 2.13 Extension Plate mm IN 54a 2.80 Length Catalog Number $ Price mm IN mm 6 4 2 71 13.39 344 AK5JB143 140.00 9 6 3 17.64 452 AK5JB144 177.00 12 8 4 21.85 560 AK5JB145 187.00 15 10 5 26.05 668 AK5JB146 230.00 24 16 8 38.69 992 AK5JB149 262.00 27 18 9 42.90 1100 AK5JB1410 360.00 Auxiliary contacts on INTEGRAL 18 will reduce maximum number of devices–see table below. Width IN mm Thermal Current Amperes Application Catalog Number $ Price 2.13 54 25 A Integral 18 & 32 & GV2 AK5PA231 2.13 54 25 A GV2 & Contactor AK5PA232 65.00 80.00 4.25 108 25 A GV2 & Reversing Contactor AK5PA232S 137.00 Table 18.148: Bus Tap-off Plugs into busbar for wiring to a separately mounted device. Width IN AK5PA232S Length of Leads Thermal Current Amperes mm Catalog Number IN $ Price mm 1.42 36 32 A 9.84 250 AK5 PC33 15.30 1.42 36 32 A 39.37 1000 AK5 PC33L 25.20 Table 18.149: Extension Plates Used to mount wider components. Bolt to standard mounting plates (after DIN rails are removed). Width IN AK5PC33 Application Catalog Number $ Price mm 2.80 71 INTEGRAL 32 AK5PE17 13.10 2.80 71 GV & Reversing contactor AK5PE27 17.50 Table 18.150: Mounting Rail Must be used for mounting plates with tap-offs. Depth Length mm mm Catalog Number 15 2000 AM1DL201 Description 75 mm Omega Rail $ Price 27.40 Table 18.151: Maximum Number of Devices Per Busbar System b Device AK5PE17 AK5PC33/PC33L b AK5 Busbar System Used with AK5PA231 Mounting Plate INTEGRAL 18 Only INTEGRAL 18 with 1 aux. block INTEGRAL 18 with 2 aux. blocks INTEGRAL 18 with 3 aux. blocks AK5PE17/27 extension plate ... JB143 4 4 3 2 3 6 JB144 6 6 4 4 4 9 JB145 8 8 6 5 6 12 JB146 10 10 7 6 8 15 JB149 16 16 12 10 13 24 JB1410 18 18 14 12 14 27 The AK5 system may be used with GV2 and GV3 devices in combination with LC1D contactors and INTEGRAL 32 devices. Table 18.152: Approvals: IEC 439, UL, CSA, DNV, LROS File E161251 CCN NMTR File LR 89150 Class 6228-01 AM1DL201 © 2007 Schneider Electric All Rights Reserved I11 Discount Schedule Modified 4/16/09 IEC CONTACTORS AND STARTERS Table 18.147: Mounting Plate Tap-off Plugs into busbar mounted on AM1DL201 DIN rail. 18-39 18 AK5PA231 Standard Width Plate mm Dimensions TeSys™ D-Line Contactors, AC Coil Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION Table 18.153: D-Line Contactors AC Control Circuits LC1D09 to D18 (3-pole) adn LC1DT12 to LC1DT40 (4 pole) LC1D25 to D38 (3-pole) Minimum electrical clearance Minimum electrical clearance Minimum electrical clearance 1.73 44 Minimum electrical clearance b b b1 b b LA4 c .39 10 c .39 10 c1 c2 c2 c3 c3 AC Coil c D09 to D18 c2 c3 IN (mm) 3.03 (77) D093 to D18 D099 to D189 IN (mm) 3.89 (99) c1 c2 c2 c3 c3 1.77 45 D25 to D38 D183 and D323 DT20 and DT25 DT203 and DT253 DT32 to DT40 DT323 and DT403 IN (mm) AC coil, without add-on accessories 3.36 (85) DC coil AC coil, with LAD4BB b 3.70 (94) 4.21 (107) 3.75 (95.5) 3.85 (98) AC coil, with LA4D*2 b 4.33 (110) a 4.84 (123) a 4.30 (111.5) a 4.48 (114) a AC coil, with LA4DF, DT b 4.68 (119) a 5.19 (132) a 4.76 (120.5) a 4.84 (123) a AC coil, with LA4DR, DW, DL b 4.96 (126) a 5.67 (139) a 5.0 (127.5) a 5.11 (130) a AC coil, without cover or add-on blocks 3.30 (84) 3.30 (84) 3.30 (84) 3.54 (90) AC coil, with cover, without add-on blocks 3.38 (86) 3.38 (86) 3.38 (86) 3.62 (92) DC coil, without cover or add-on blocks 3.66 (93) 3.66 (93) 3.66 (93) 3.89 (99) DC coil, with cover, without add-on blocks 3.76 (95) 3.76 (95) 3.76 (95) 3.97 (101) AC coil, with LADN or C (two or four contacts) 4.60 (117) 4.60 (117) 4.60 (117) 4.84 (123) DC coil, with LADN or C (two or four contacts) 4.96 (126) 4.96 (126) 4.96 (126) 5.19 (132) AC coil, with LAD6K10 5.07 (129) 5.07 (129) 5.07 (129) 5.31 (135) DC coil, with LAD6K10 5.43 (138) 5.43 (138) 5.43 (138) 5.66 (144) AC coil, with LADT,R,S 5.39 (137) 5.39 (137) 5.39 (137) 5.62 (143) AC coil, with LADT,R,S and sealing cover 5.55 (141) 5.55 (141) 5.55 (141) 5.78 (147) DC coil with LADT,R,S 5.76 (146) 5.76 (146) 5.76 (146) 5.98 (152) DC coil with LADT,R,S and sealing cover 5.90 (150) 5.76 (146) 5.76 (146) 6.14 (156) a Including LAD4BB b Not applicable to devices with DC coils IN (mm) 3.14 (80) IN (mm) 3.89 (99) IN (mm) 3.34 (85) IN (mm) 3.89 (99) IN (mm) 3.58 (91) IN (mm) 4.13 (105) 4.21 (107) 4.84 (123) a 5.19 (132) a 5.47 (139) a 3.54 (90) 3.62 (92) 3.89 (99) 3.97 (101) 4.84 (123) 5.19 (132) 5.31 (135) 5.66 (144) 5.62 (143) 5.78 (147) 5.98 (152) 6.14 (156) 3.85 (98) 4.48 (114) 5.02 (129) 7.48 (190) 3.54 (90) 3.62 (92) — 3.90 (99) 4.84 (123) 4.84 (123) 5.31 (135) 5.31 (135) 5.62 (143) 5.78 (147) 5.62 (143) 5.78 (147) — — — — 3.54 (90) 3.62 (92) — 3.90 (99) 4.84 (123) 4.84 (123) 5.31 (135) 5.31 (135) 5.62 (143) 5.78 (147) 5.62 (143) 5.78 (147) — — — — 3.85 (98) 3.93 (100) — 4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143) 5.62 (143) 5.94 (151) 6.10 (155) 5.94 (151) 6.10 (155) — — — — 3.85 (98) 3.93 (100) — 4.21 (107) 5.15 (131) 5.15 (131) 5.62 (143) 5.62 (143) 5.94 (151) 6.10 (155) 5.94 (151) 6.10 (155) Table 18.154: AC Coil LC1D80004 (4P) 5.20 (LA4 DA2, DE2) 132 5.59 (LA4 DF, DT) 142 5.91 (LA4 DM, DR, DW, DZ) 150 4.49 114 5.75* (LA1) 146 6.50** (LA2, LA3, LA6 DK1) 165 .51 13 (LA8) 2.95 (3P) 3.34 (4P) 85 75 .51 13 (LA8) xcept LA1DN10, DN01 = 136 +4 mm with lead sealing device 5.51 (LA4 DA2, DE2) 140 5.79 (LA4 DF, DT) 147 6.18 (LA4 DM, DR, DW, DZ) 157 LC1D40, D50, D65 (3P), LC1D65004 (4P) 4.92 125 5.00 127 5.00 127 6.02* (LA1) 153 6.77** (LA2, LA3, LA6 DK2) 172 .51 13 (LA8) 3.34 (3P) 3.78 (4P) 96 85 .51 13 (LA8) *except LA1DN10, DN01 = 136 ** +4 mm with lead sealing device Table 18.155: DC Coil .47 12 6.73 171 8.03* (LA1) 204 8.78d (LA6 DK2, LA2, LA3) 223 *except LA1DN10, DN01 = 136 d + 4 mm with lead sealing device 18-40 7.13 181 2.95(3P) 3.34(4P) 75 85 4.96 126 .47 12 LC1D80 (3P), LC1D800004(4P) 5.51 (LA4 DC3) 140 5.79 (LA4 DF, DT) 147 6.06 (LA4 DM, DR, DW, DZ) 154 LC1D40, D50, D65 (3P), LC1D650004, (4P) 4.96 126 IEC CONTACTORS AND STARTERS c1 c .39 10 c1 1.77 45 5.20 (LA4 DC3) 132 5.47 (LA4 DF, DT) 139 5.75 (LA4 DM, DR, DW, DZ) 146 18 b1 .51 13 (LAD8) DC Coil LC1 b c .39 10 c1 8.27* (LA1) 210 9.02d (LA6 DK3, LA2, LA3) 223 3.34 (3P) 3.78(4P) 85 96 *except LA1DN10, DN01 = 143 d + 4 mm with lead sealing device © 2007 Schneider Electric All Rights Reserved Dimensions TeSys™ D-Line Contactors, DC Coil Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION = 5.12 130 6.22 158 = LC1D115, D150 Panel mounted with 1/4” screws c = G = LC1 D115 D1156 D150 D1506 c 5.12 (132) 4.53 (115) 5.12 (132) 4.53 (115) G (3-poles) 3.78/4.33 (96/110) 3.78/4.33 (96/110) G (4-poles) 5.12/5.67 (130/144) 5.12/5.67 (130/144) 3.78/4.33 (96/110) 3.78/4.33 (96/110) — — 6.22 158 LA4 LA8 c LC1 D115, D150 D115004 D1156, D1506 D1150046 C 5.12 (132) 5.12 (132) 4.53 (115) 4.53 (115) A 4.72 (120) 6.10 (155) 4.72 (120) 6.10 (155) IEC CONTACTORS AND STARTERS 6.61c (LA2, LA3) 168 6.85 (LA4D•2, D•3) 174 7.28 (DF, DT) 185 7.40 (DM, DR, DW, DL) 188 LC1D115, D150 a 5.91q (LA1) 150 6.10 (LA6-DK20) 155 a b With 2 or 4 contacts. + 4 mm with sealing cover. LR9D solid-state overload relay Direct mounting beneath contactors LC1D115 and D150 5.20 132 d 10.04 255 4.72 120 35 mm DIN rail dimensions AM1DP200 and DR200 AM1DE••• and ED••• d 0.10 (2.5) .41 (10.5) Note: All dimensions are in Inches (mm). © 2007 Schneider Electric All Rights Reserved 5.20 132 d 35 mm DIN rail dimensions AM1DP200 and DR200 d 0.10 (2.5) 5.35 136 6.85 174 5.91 150 7.44 189 10.51 267 18 LR2D4 bimetallic overload relay Direct mounting beneath contactors LC1D115 and D150 4.72 120 AM1DE••• and ED••• .41 (10.5) 18-41 Dimensions TeSys™ F-Line Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION All dimensions shown in mm. To convert to inches divide by 25.4. LC1F15 to F330 S s1 Table 18.156: a M b2 a b b1 b2 c f G G1 J J1 = b = F115 LC1 c Q L P Q1 P a 18 c f X1 Protective cover Type LA9F70•. = a F150 F185 433-Pole Pole Pole 4-Pole 163.5 200.5 163.5 200.5 162 162 170 170 137 137 137 137 265 265 301 301 165b 165b 165b 165b 131 131 131 131 106 143 106 143 80 80 80 80 106 106 106 106 120 120 120 120 F265 F330 343434Pole Pole Pole Pole Pole Pole 168.5 208.5 201.5 243.5 213 261 174 174 203 203 206 206 137 137 145 145 145 145 305 305 370 370 375 375 176 176 207 207 219 219 130 130 147 147 147 147 111 151 142 190 154.5 202.5 80 80 96 96 96 96 106 106 106 106 106 106 120 120 120 120 120 120 IEC CONTACTORS AND STARTERS L 107 107 107 107 113.5 113.5 141 M 147 147 150 150 154 154 178 P 37 37 40 40 40 40 48 Q 29.5 29.5 26.5 26 29 29 39 Q1 60 60 57.5 55.5 59.5 59.5 66.5 S 15 15 20 20 20 20 25 S1 27 27 34 34 34 34 38 Y 44 44 44 44 44 44 38 Z 13.5 13.5 13.5 13.5 13.5 13.5 21.5 Note: f = minimum distance required for coil removal. 141 178 48 34 66.5 25 38 38 21.5 145 181 48 43 74 25 44.5 38 20.5 145 181 48 43 74 25 44.5 38 20.5 b1 = J J1 Table 18.157: = Z G1 = G Y LC1F400 to F500 S 2.20 56 Table 18.158: 1.49 38 LC1 = M10 X 30 dia. M b2 b = 8.23 209 e Q L X1 P c Q1 P a f = = 7.09 180 = = 4.7 120 8 X 8.5 dia. G .92 23.5 G1 Dual Dimensions: 18-42 Voltage in V 220/380 415/440 500 660 1000 LC1F115, F150 20 25 30 40 20 LC1F185 20 25 30 40 30 LC1F265 20 25 40 50 40 LC1F330 25 35 40 50 50 b +6 mm with time delay block (for F115 and F150). c Optimal terminal shroud Note: X1: Minimum clearance according to the operational voltage and the breaking capacity. J a b b2 c f F400 2-Pole 213 206 375 213 119 3-Pole 213 206 375 213 119 F500 4-Pole 261 206 375 213 119 2-Pole 233 238 400 226 141 3-Pole 233 238 400 226 141 4-Pole 288 238 400 226 141 Gd 80 80 80 80 80 140 G min. 66 66 66 66 66 66 G max. 102 102 150 120 120 175 G1d 170 170 170 170 170 230 G1 min. 156 156 156 156 156 156 G1 max. 192 192 240 210 210 265 d Supplied J 19.5 19.5 67.5 39.5 39.5 34.5 L 145 145 145 146 146 146 M 181 181 181 208 208 208 P 48 48 48 55 55 55 Q 69 43 43 76 46 46 Q1 96 74 74 102 77 77 S 25 25 25 30 30 30 Note: f = Minimum distance required for coil removal. Note: X1: Minimum clearance according to the operational voltage and the breaking capacity. Table 18.159: Voltage in V 220/230 LC1F400 30 LC1F500 40 e Protective cover. 415/440 40 45 500 40 50 660 50 60 1000 60 60 INCHES Millimeters © 2007 Schneider Electric All Rights Reserved Dimensions TeSys™ F-Line Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION LC1F630 and LC1F800 2.52 64 1.57 40 2.83 72 Dual Dimensions: 6 x M12 x 45 INCHES Millimeters c = = 7.09 180 10.39 264 18.28 464 11.02 280 11.97 304 = = 4 x Dia. 10.5 mm 9.84 250 7.76 197 6.10 155 3.15 80 Q 3.15 80 G supplied G min. J1 7.13* 181 a a G 2.38 60 Q1 G max. J1 Q Q1 IEC CONTACTORS AND STARTERS X1 LC1F630 * = minimum distance required for coil removal. c Protective cover. IN mm IN mm IN mm IN mm IN mm IN mm IN mm 2P 12.17 309 7.09 180 3.94 100 7.68 195 2.70 68.5 4.02 102 5.00 127 3P 12.17 309 7.09 180 3.94 100 7.68 195 2.70 68.5 2.36 60 3.50 89 Voltage in V 380 415/440 4P 15.31 389 9.45 240 5.91 150 10.83 275 2.70 68.5 2.36 60 3.50 89 X1 in mm 60 60 X1:Minimum clearance according to the operational voltage and the breaking capacity. 500 660 1000 60 70 80 LC1F780, F7804 18 = 15.74 400 17.08 434 13.70 348 11.02 280 .86 22 = 1.02 26 12 x M14 x 45 1.02 26 2.36 60 6.50 165 9.84 250 X1 6.30 160 7.52 191 27.64f 702 7.20* 183 380 415/440 660 1000 X1 in mm 90 100 120 120 LC1F780 mounting 7.52 191 7.20* 183 f Overall length (3 poles) X1: Minimum clearance according to the operational voltage and the breaking capacity. Voltage in V 6.30 160 33.93a 862 a Overall length (4 poles) *minimum distance required for coil removal. 5.00 127 7.09 180 8 x Dia. 10.5 mm 5.00 127 6 x Dia. 10.5 mm 7.09 180 5.00 127 5.00 127 LC1F7804 mounting 3.50 90 9.45 240 © 2007 Schneider Electric All Rights Reserved 9.45 240 5.20 132 3.50 90 9.45 240 7.48 190 9.45 240 4.00 102 18-43 Dimensions TeSys™ D-Line Reversing Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION 2 x LP1D40 , D65, D80, D95 LC2D09 to D32 LC2DT20 to DT60 2 x LC1DT20 to DT60 G1 = 4.33 110 = 2.36 60 b 3.94 100 b 2.76 70 = c a IN (mm) DT20 and DT25 3.54 (90) DT32 to DT60 3.54 (90) c, e2: includes cabling. b c G IN (mm) 3.34 (85) 3.58 (91) IN (mm) 3.54 (90) 3.85 (98) IN (mm) 3.14 (80) 3.14 (80) a LC2 or 2 x LC1 b c 1.57 40 G e1 e2 a 1.57 40 G = G1 IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) IN (mm) D40 to D65 7.16 (182) 5.0 (127) 7.4 (190) 1.19 (5) 0.43 (11) 2.2 (57) 3.8 (97) D80 and D95 8.14 (207) 5.0 (127) 8.4 (215) 0.51 (13) 0.78 (20) 3.7 (96) 4.3 (111) c, e1 and e2: includes cabling. = e1 Dimensions shown in millimeters (mm ÷ 25.4 = inches) = 5.12 130 6.22 158 IEC CONTACTORS AND STARTERS LC2D115 and D150 2 x LC1D115 and D150 Panel mounted with 1/4” screw e2 18 a LC2 or 2 x LC1 = e2 = G = e2 c .51 13 2xM0.16 2xM4 = .31 8 e1 6xØ0.26 6xØ6.5 = G c = a LC2 or 2 x LC1 (3-pole) D115, D150 LC2 or 2 x LC1 (4-pole) a 266 a c 148 c e1 56 e1 e2 18 e2 G 242/256 G D115 c, e1 and e2 includes cabling 334 148 — 60 310/324 NOTE: For dimensions of F-Line reversing contactors, please refer to Catalog 8502CT9901. 18-44 © 2007 Schneider Electric All Rights Reserved Dimensions TeSys™ D-Line Overload Relays Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION LRD-01-35 Independent mounting on 50 mm centers or on rail AM1DP200 or DE200 Independent mounting on 110 mm centers 1.38 35 1.81 46 = = LAD7B106 .39 10 1.77 45 4.33 110 4.92 125 = .08 2 .24 6 3.15 80 .20 5 1.50 38 1.97 50 3.15 80 .59 15 = LAD7B106 DX1AP25 3.54 90 2xØ0.26 2xØ6.5 LRD, LR2D and LR9D “Reset” by flexible cable LA7D305 and LAD7305 Mounting with cable straight Remote tripping or electrical reset Mounting with cable bent e 1.26 32 Can only be mounted on RH side of relay LRD-01 to 35 2xØ0.18 2xØ4.5 1.71 43.5 0.31 8 0.67 17 LR2D1, LR3D1 Seperate mounting at 110 mm (4.33”) centers d 0.51 2xØ0.18 2xØ4.5 0.87 13 22 LR2D2, LR3D2 Seperate mounting at 110 mm (4.33”) centers 2.24 57 = = = 1.81 46 = DX1AP25 3.86 98 = LA7D2064 DX1AP25 LA7D1064 = = d = 3.54 90 1.97/2.56 50/65 0.16 4 3.11 79 1.48 43.5 3.86 98 LA7-D2064 = 2.17 55 1.57 40 18 LR2D2, LR3D2 Seperate mounting at 50 mm (1.97”) centers or on AM1DP200 or DE200 rail 1.97/2.56 50/65 1.77 45 1.38 35 = M10x0.04 M10x1 c: up to 21.6in (550 mm) e: up to 0.79in (20 mm) LR2D1, LR3D1 Seperate mounting at 50 mm (1.97”) centers or on AM1DP200 or DE200 rail LA7-D1064 e 0.12 3 a c Mounting Holes 1.97 4.33 50 110 4.92 125 1.97 50 Mounting Holes © 2007 Schneider Electric All Rights Reserved 2 x Ø6.5 mm Screws = = 4.33 110 4.92 125 4.25 108 4.25 108 IEC CONTACTORS AND STARTERS LAD703 c 2 x Ø6.5 mm Screws 18-45 Dimensions TeSys™ D-Line Thermal Overload Relays Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION LRD-01-35 Direct mounting beneath contactors with screw 18 LC1• LRD-013-353 Direct mounting beneath contactors with spring terminal connections LC1• b D09–D18 D25–D38 4.84 (123) 5.39 (137) See Catalog 8502CT9901 pages 122, 123. b c D093–383 4.84 (123) See Catalog 8502CT9901 pages 122, 123. c IEC CONTACTORS AND STARTERS LRD-3••• Direct mounting beneath contactors LC1-D40 to D95 and LP1-D40 to D80 AM1• DL201 DL200 d 0.28 (7) 0.67 (17) b LC1D40 LC1D50 LC1D65 LC1D80 LC1D95 LC1D40, LP1D40 LC1D50 LC1D65, LP1D65 LC1D80, D95, LP1D80 LRD4••• Direct mounting beneath contactors LC1D115 and D150 d 18-46 c e AC Control Circuit 4.37 (111) 4.69 (119) 2.85 (72.4) 4.37 (111) 4.69 (119) 2.85 (72.4) 4.37 (111) 4.69 (119) 2.85 (72.4) 4.55 (115.5) 4.88 (124) 3.03 (76.9) 4.55 (115.5) 4.88 (124) 3.03 (76.9) DC Control Circuit 4.37 (111) 6.93 (176) 2.85 (72.4) 4.37 (111) 6.93 (176) 2.85 (72.4) 4.37 (111) 6.93 (176) 2.85 (72.4) 4.55 (115.5) 7.06 (179.4) 3.03 (76.9) g(3P) g(4P) 0.18 (4.5) 0.18 (4.5) 0.18 (4.5) 0.37 (9.5) 0.37 (9.5) 0.51 (13) — 0.51 (13) 0.87 (22) — 0.18 (4.5) 0.18 (4.5) 0.18 (4.5) 0.51(13) — 0.51(13) 0.37 (9.5) 0.87(22) LR9D Direct mounting beneath contactors LC1D115 and D150 AM1DL200 and DR200 AM1DE200 and ED••• 0.10 (2.5) 0.41 (10.5) d a For Additional characteristics and Catalog Number information, see Catalog 8502CT9901 AM1DP200 and DR200 0.10 (2.5) AM1DE200 and ED••• 0.41 (10.5) © 2007 Schneider Electric All Rights Reserved Dimensions TeSys™ F-Line Overload Relays Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION bc 2.80 71 2.80 71 4.53 115 4xØ5.5 .79 20 P1 P2 Ø11 1.18 30 4xØ5.5 3.15 80 Ø13 3.15 80 2.44 62 1.57 40 3.23 82 5.39 137 .24 6 .87 22 2.76 70 5.94 151 7.44 189 4.29 109 .98 25 2.05 52 2.60 66 9.02 229 1.77 45 2.05 52 2.60 66 1.57 40 P1 48 55 LR9F7•75 LR9F7•79, F7•81 Terminal shroud LA9-F70• 7.87 200 .79 20 .55 14 1.65 42 IEC CONTACTORS AND STARTERS LR9F7•81 (for mounting beneath LC1F630) .24 6 c 2.36 60 3.78 96 1.97 50 2.36 60 2.99 76 LR9F7•75, F7•79, F7•81 Common side view f 4.72 120 4xØ5.5 4.53 115 1.85 .11 47 3 Terminal shroud LA9F70• 6.5 x 13.5 for LR9F5•57 and 8.5 x 13.5 for LR9F5•63, F5•67, F5•69 5.04 128 1.97 50 1.97 50 1.57 40 2.99 76 1.89 48 3.98 101 .98 25 1.97 50 1.57 40 18 a b 1.89 48 Ø11 .22 6 2.24 57 1.77 45 a q 4.88 124 .11 3 LR9F5•57, F5•63, F5•67, F5•69 .22 6 LR9F5•71 Common side view P2 48 55 3.03 77 3.03 77 Direct mounting beneath reversing contactors or star-delta contactors b H1 b H3 H3 Direct mounting beneath contactor LC1-F 7.60 193 H2 H2 H4 LA7F40 e LA7F40p Bar Busbar Bus d d LC1 contactors F115 F150 F185 F225 F265 F330 F400 F500 F630 With LR9 relays b H1 H2 F5•57, F5•63, F5•67, F5•69 240 30 76 F5•57, F5•63, F5•67, F5•69 246 30 76 250 30 76 F5•57, F5•63, F5•67, F5•69 F5•71 273 40 76 F7•75, F7•79 308 50 108.8 279 40 76 F5•71 F7•75, F7•79 314 60 108.8 F7•75, F7•79 317 60 108.8 317 60 108.8 F7•75, F7•79, F7•81 F7•75, F7•79, F7•81 346 70 108.8 F7•81 510 110 108.8 d Relay mounting plate, see page 18-21. e Connection Accessories, see page 18-21. © 2007 Schneider Electric All Rights Reserved H3 120 120 120 120 120 120 120 120 180 180 180 LC1 contactors F115 F150 F185 F225 F265 F330 F400 F500 F630 With LR9 relays F5•57, F5 • 63, F5•67, F5•69 F5•57, F5•63, F5•67, F5•69 F5•57, F5•63, F5•67, F5•69 F5•71 F7•75, F7•79 F5•71 F7•75, F7•79 F7•75, F7•79 F7•75, F7•79, F7•81 F7•75, F7•79, F7•81 F7•81 b 279 283 285 319 360 332 363 364 364 390 509 H4 60 60 60 80 100 90 100 100 100 110 120 H2 76 76 76 76 108.8 76 108.8 108.8 108.8 108.8 108.8 H3 120 120 120 120 120 120 120 120 180 180 180 18-47 Dimensions TeSys™ D-Line Combination and Non-combination Starters Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION NEMA 1 D09-25 (FVNR) D09-40 (FVR); D32-40 (FVNR) 10.00 254 5.00 7.50 127 191 3.00 7.50 76 191 18.00 203 419 16.50 R 318 12.52 18 14.02 18 356 .69 457 8.00 R IEC CONTACTORS AND STARTERS Provision for 1/4" Screw Provision for 1/4" Screw NEMA 12/3R D09-25 (FVNR) D09-40 (FVR); D32-40 (FVNR) 10.00 254 5.00 7.75 127 197 8.00 3.00 7.75 457 18.00 499 19.63 356 14.00 378 18.88 197 397 15.63 14.88 76 480 203 R R Provision for 1/4" Screw Provision for 1/4" Screw A 13 .50 Non-combination Starter Dimensions .75 E B 19 J K C R F 14 .56 D/2 D G H Provision for 1/4" Screw Table 18.160: Non-combination Starter Dimensions TYPE 1 Non-reversing D09-32 D40-65 D80 Reversing — D09-32 D40-80 A 6.77 8.66 10.63 B 10.04 10.83 13.98 C 6.25 7.21 7.21 D 5.38 7.25 9.22 E 9.00 9.75 12.94 F 1–1.25 1.25–1.5 1.25–1.5 TYPE 12/3R G 0.5–0.75 0.5–0.75 0.5–0.75 H — 1–1.25 1–1.25 J 1–0.25 1–0.25 1–1.25 K 0.5–0.75 0.5–0.75 0.5–0.75 D 5.38 5.38 5.38 E 11.37 12.15 15.30 Note: All dimensions in inches. 18-48 © 2007 Schneider Electric All Rights Reserved Dimensions TeSys™ K-Line Contactors Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION LR2K Direct mounting under the contactor Separate mounting with LA7-K0064 terminal block on 35 mm (AM1DP200 or AM1DE200) 1.38 35 4.57 116 2.28 58 2.56 65 3.15 80 1.50 38 4 x Ø4 1.97 50 .31 8 rail 1.77 45 1.77 45 13 A1 13 5 3 Wiring Scheme 1 Three-phase 2.95 75 3.09 (DP200) 78 3.38 (DE200) 86 95 95 Internal Links 96 98 A2 96 Test LC1, LP1, LP4K mini-contactors On baseplate 96 6 98 LC2, LC8, LP2, LP5K reversing mini-contactors On baseplate LA1-K 8 x Ø4 2.28 58 1.97 50 2.28 58 4 x Ø4 1.38 35 1.77 45 2.24 57 1.97 50 LA1-K 2.24 57 1.22 31 3.15 80 3.54 90 On AM1DP200 or DE200 rail ( 35 mm) 2.28 58 2.28 58 On AM1DP200 or DE200 rail ( 35 mm) 2.24 57 On printed circuit board 2.24 57 1.77 45 3.54 90 On printed circuit board for reversing contactors or 2 mini-contactors side-by-side A1 10 x Ø.051 10 x Ø1.3 .34 9 1.77 45 .34 A1 9 A1 2.28 58 1.97 50 2.05 52 2.28 58 .34 9 A2 20 x Ø.051 20 x Ø1.3 A2 1.97 50 2.05 52 1.22 31 95 4 2 97 A1 – KM1 Reset/Stop 1.77 45 1.77 45 A2 Table 18.161: LA2KT Electronic time delay contact blocks On mini-contactors or reversing mini-contactors 1.34 34 Dual Dimensions: © 2007 Schneider Electric All Rights Reserved 2.28 58 1.06 27 LA2-KT 1.50 38 INCHES Millimeters 1.34 34 2.24 57 18-49 18 96 6 4 2 O IEC CONTACTORS AND STARTERS 14 A2 6 4 2 95 97 14 – KM1 5 3 1 A H Dimensions TeSys™ U-Line Motor Starters Refer to Catalog 8502CT0201 www.us.schneider-electric.com FOR CURRENT INFORMATION Starter Controllers Reversing Rail Mounting 126 4.96 1.18 Ø4 .15 1.14 163 6.42 224 8.82 73 2.87 154 6.06 X1 45 X2 1.77 Screw Mounting 29 30 X2 135a 5.31 Rail Mounting 135a 5.31 120/125 4.72/4.92 X1 126 4.96 Screw Mounting Ø4 .15 233 9.17 Non-reversing 45 1.77 18 Note: Minimum electrical clearance: X1 = 35 mm for Ue = 440 V and 70 mm for Ue = 500 and 690 V, X2 = 0 a Maximum depth (with MODBUS® communication module) Reversing block for mounting separately from power base Rail Mounting Screw Mounting 104 4.09 115 4.53 113 4.45 113 4.45 45 1.77 36 1.41 93 3.66 Limiter disconnector LUALB1 154 6.06 135a 5.31 a 45 1.77 Maximum depth (with MODBUS communication module) Door interlock mechanisms LU9AP00 Door cut-out = = 54 2.12 55 2.16 Ø43 1.69 230 9.06 IEC CONTACTORS AND STARTERS Ø4 .15 = = 54 2.12 4xØ3.5 .13 Dual Dimensions: 508 20.01 18-50 11.5 .45 8 .31 INCHES Millimeters Ø7 .27 © 2007 Schneider Electric All Rights Reserved Dimensions Altistart U01 and TeSys™ U-Line Soft Starters Refer to Catalog 8502CT9901 www.us.schneider-electric.com FOR CURRENT INFORMATION TeSys U-Line combination (non-reversing power base) and ATSU 01N212LT Mounting on § (35mm) rail with VW3 G4104 connector TeSys U-Line combination (non-reversing or reversing power base) and ATSU 01N2206LT to ATSU 01N212LT Side-by-side mounting 45 1.77 135 5.31 284 11.18 150 5.91 124 4.88 154 6.06 72.2 2.84 99 3.9 9 0.354 IEC CONTACTORS AND STARTERS 9 0.354 TeSys U-Line combination (non-reversing or reversing power base) and ATSU 01N222LT to ATSU 01N232LT Side-by-side mounting TeSys U-Line combination (non-reversing power base) and ATSU 01N222LT to ATSU 01N232LT Mounting on § (35mm) rail with VW3 G4104 connector 135 5.31 18 154 6.06 72.2 2.84 45 1.77 99 3.9 314 12.36 170 6.69 9 0.354 VW3 G4104 Power connector 46.6 1.83 9 0.354 44.8 1.76 6 0.24 28 1.10 20 0.79 © 2007 Schneider Electric All Rights Reserved 18-51 Dimensions TeSys™ Manual Starters and Protectors Refer to Catalog 2520CT0001 www.us.schneider-electric.com FOR CURRENT INFORMATION GV2AD, AM, AN, AU, AS, AX GV2AE Block GV2AD, AM, AN Block GV2AU, AS, AX Mounting of GV2M On 35 mm rail C = 78.5 mm (3.09") on AM1DP200 (35 x 7.5 mm) C = 86 mm (3.39") on AM1DE200, ED200 (35 x 15 mm) 16 44 .63 1.73 66 2.60 44.5 1.75 44.5 1.75 9.3 .37 GV2P 9.3 .37 81 3.19 18 .71 c GV2AD, AM, AN, AU, AS, AX 14 .55 On 35 mm rail C = 98.5 mm (3.88") on AM1DP200 (35 x 7.5 mm) C = 106 mm (4.17") on AM1DE200, ED200 (35 x 15 mm) 98 3.86 32 1.26 = Block GV2AD, AM, AN Block GV2AU, AS, AX Mounting of GV2P 44.5 1.75 9.3 .37 9.3 .37 81 3.19 18 .71 44.5 1.75 GV2P + GV2GH7 for UL 508 Type E application b b IEC CONTACTORS AND STARTERS c1 45 1.77 c c1 d1 c 3.6 (91.4) 3.6 (91.4) 3.8 (96.52) 3.8 (96.52) 44 1.73 45 1.77 c 13.5 .53 GV2P + GV2GH7 + D-Line contactor for UL 508 Type E application 103 4.07 GV2AF4 + LAD31 Combination GV2ME + D range contactor Combination GV2P + D range contactor d GV2ME + b c1 c d1 d LC2D09 to D18 7.4 (188.6) 3.6 (92.7) 3.9 (98.2) 3.9 (98.3) 4.1 (103.8) LC2D25 and D32 7.8 (199) 3.9 (99) 4.11 (104.5) 3.9 (98.3) 1.4 (103.8) GV2P + b c1 c — — • LC2D25 and D32 7.9 (199.5) 4.6 (116.8) 4.8 (122.3) — — • (bracket cut-out) Flush mounting enclosure GV2MP0 = Surface mounting enclosure GV2MC0 a LC2D09 to D18 6.61 (168.1) 4.6 (116.8) 4.8 (122.3) — — 84 3.31 93 3.66 a = 13 0.51 = 1...6 /0.04...0.24 84 3.31 = 93.5 3.68 106.5 4.19 = 71 2.8 6.5 0.25 92.8 3.65 4 knock-outs for 16 mm plastic cable glands or no. 16 conduit. GV2 MP01, MP02 MP03, MP04 18-52 b 130 5.12 = 147 5.79 b1 = 2xØ5.3x6.3 = 18 15 .59 50 1.97 82 3.23 191 7.50 26 1.02 44.5 1.75 = 44.5 1.75 45 1.77 61 2.40 89 3.50 GV2AK00 84 3.31 11 .43 44.5 1.75 = 89 3.5 45 1.77 = 15 .59 10 .39 GV2M b IN 5.51 5.24 b1 mm 140 133 IN 5.00 4.61 mm 127 117 © 2007 Schneider Electric All Rights Reserved Dimensions TeSys™ Manual Starters and Protectors Refer to Catalog 2520CT0001 www.us.schneider-electric.com FOR CURRENT INFORMATION GV2M with GK2AF01 and LC1K GV2M with GV2AF01 and LC1K GV2M with GV2AF01 and LC2K Adapter plate GK2AF01 5 .2 35 1.38 dimensions in mm 4xØ3.5 Ø43 0.14 1.7 80 3.15 Sets of bus bars, GV2G445, GV2G454, GV2G472 with terminal block GV2G05 Sets of bus bars GV2G245, GV2G254, GV2G272 p l 1.2 30 l 18 2.5 63 .71 18 .12 3 Sets of bus bars with terminal block GV1G09 35 1.38 13 0.51 35 1.38 IEC CONTACTORS AND STARTERS 50/60 1.97/2.36 = 54 2.13 = = 54 2.13 5.2 0.21 = = 7.5 mm height compensation plate GV1F03 4.2 .17 = 1.5...5/0.06...0.20 min.=150 max.=290 5.91 11.42 35 1.38 GV2M on panel with GV2AF02 adapter plate Door cut-out 7 .276 53 2.1 54 2.13 9.5 .37 39 1.54 Mounting external operator GV2AP0• 65 2.56 24 .94 90 3.54 45 1.77 79 3.11 105 ± 5 4.13 ± .2 135 5.31 45 1.77 45 1.77 152 6.0 152 6.0 55 2.17 Ø5.5 .22 1.8 45 GV2G445 GV2G454 GV2G472 I 7.0" (179 mm) 8.1" (206 mm) 10.2" (260 mm) 0.16 x 1.8" (4 x 45 mm) 0.16 x 2.1" (4 x 54 mm) 0.16 x 1.8" (4 x 45 mm) P 1.8" (45 mm) 2.1" (54 mm) 2.8" (72 mm) GV2G245 GV2G254 GV2G272 GV2G354 I 3.5" (89 mm) 3.9" (98 mm) 4.6" (116 mm) 6.0" (152 mm) 0.08 x 1.8" (2 x 45 mm) 0.08 x 2.1" (2 x 54 mm) 0.08 x 2.8"(2 x 72 mm) 0.12 x 2.1" (3 x 54 mm) GV3 P Dimensions Mounting on rail AM1 DE200 or AM1 ED201 X1 (1) 64 64 132 68 68 (2) 144 55 X1 136 9 18 Blocks GV ANpp , GV ADpp , GV AM11 Block GV3 AUpp and GV3 ASpp Mounting on pre-slotted mounting plate AM1 PA X1 = Electrical clearance (ISC max) 40 mm for Ue < 500 V, 50 mm for Ue < 690 V Mounting on panel, using M4 screws 16 183 3xØ4 136 37,5 137,5 137,5 AF1 EA4 136 18,7 18,7 Note: Leave a space of 9 mm between 2 circuit-breakers: either an empty space or side-mounting add-on contact blocks. Horizontal mounting is possible: please consult your regional sales office. © 2007 Schneider Electric All Rights Reserved 18-53 Dimensions TeSys™ GV7 Manual Starters and Protectors www.us.schneider-electric.com FOR CURRENT INFORMATION 1 GV7R Panel Mounting Flush Mounting side by side 4.25 108 = = 4.25 108 = = 4.92 125 1.85 3.0 47 76 = 2xØ0.24 2xØ6 = 1.14 29 == 1.14 29 3.27 83 Minimum clearance 18 Painted or insulated metal plate, insulation or insulated bar Bare metal plate U < 440 V 440 V < U < 600 V U > 600 V = = 4.25 108 x1 x2 IN (mm) 0 (0) 0.20 (5) 0.39 (10) IN (mm) 1.18 (30) 1.38 (35) 1.38 (35) 0.79 (20) 1.38 (35) x2 3.46 88 x1 x1 x2 1.38 1.38 1.38 35 35 35 IEC CONTACTORS AND STARTERS Note: Minimum distance between 2 units mounted side by side = 0. 21 22 24 82 84 81 92 94 91 11 14 12 Add-on auxiliary contacts, GV7AE11, GV7AB11 5/L3 3/L2 1/L1 Motor controllers GV7R 6/T3 4/T2 2/T1 Note: A self-adhesive label, supplied with the contact, can be affixed to the front face of the starter to allow personalized marking according to the function of the contact or contacts. GV7AS••• GV7AD111, AD112 50 ms 98 97 50 ms 13 97 D4 C2 97 D1 C1 GV7AU••• 50 ms 21 23 98 14 98 – KA1 18-54 A1 – KM1 A2 – KA1 A2 – KA1 B1 A1 22 24 – KA1 © 2007 Schneider Electric All Rights Reserved Dimensions TeSys™ GV7 Manual Starters and Protectors www.us.schneider-electric.com FOR CURRENT INFORMATION GV7AC03 Spreaders 1.61 41 4.49 114 1.77 1.77 45 45 1.18 30 Smooth Terminals a Connectors Z 2.76 70 0.75 19 Z 2.76 70 X X X IEC CONTACTORS AND STARTERS Z 0.41 10.5 Cabling a (in/mm) 0.77/19.5 0.85/21.5 • • GV7R GV7R 220 GV7AP03, GV7A04 60 0 1.10 28 6.10 155 © 2007 Schneider Electric All Rights Reserved 4.76 121 3.58 91 2.17 55 1.42 36 1.14 29 3.5 89 = 18 DD 73 1.77 2.87 45 I 60 Flush Mounting 1.85 3.0 47 76 Direct Rotary Handle = 3.82 97 18-55 Dimensions TeSys™ GV7 Manual Starters and Protectors www.us.schneider-electric.com FOR CURRENT INFORMATION GV7AP03 or GV7AP04, GV7AP05 Direct Rotary Handle Front Fuse Center Enclosure viewed from top 0.36 9.25 = 0.35 9 3.94 100 4.72 120 2.32 59 = h e 1.61 41 4.92 125 4.72 120 2.72 69 2.0 51 = = d Door cutouts require a minimum distance between the center of the circuit breaker and the door hinge point d ≥ 3.94 in (100 mm) + (h x 5) 3.94 100 GV7AP01, GV7AP02 Extended Rotary Handle 0.36 9.25 18 = = I 2.95 75 0.35 9 60 0 IEC CONTACTORS AND STARTERS 60 l = = 2.95 75 Note: I: 7.28" (185 mm) minimum, 23.62" (600 mm) maximum. The shaft of the extended rotary handle GV7AP01 or GV7AP02 must be cut to length: I - 4.96" (126 mm) 18-58 © 2007 Schneider Electric All Rights Reserved