EX AF B 001 2 U0 N 000/ AEX24-1-S/U 15 Nm explosion proof spring return actuator. On-Off control. Rotation 95° Features EEx d IIC T6 Damper actuator according to the European Standards EN 50014 EN 50018, flameproof enclosure tested by CESI. EEx d llC T6. The actuator moves the damper to its working position while tensioning the return spring until it is powered. If the power supply is interrupted the spring moves the damper back to its safe position. The actuator is overload protected and can be mechanically stopped in any position. The actuator can be mounted directly on the damper shaft if square, 12 x 12 mm or 10 x 10 mm (adaptor included); several mounting brackets are available for applications where the actuator cannot be directly coupled to the damper shaft. The cable glands are fit for cable diameters from 8 to 10,5 mm. CENELEC EN 50014/50018 Approved by CESI EX-99.E.059 NEMKO 0470 03ATEX1242 INCLUDED: EEx d actuator EEx e terminal box Mounting brackets Note: For installation, use and maintenance the official standards and rules must be applied. II 2GD EEx d llC T6 For zones 1 and 2 Technical data Power supply Power consumption - running - stand-still Transformer sizing Torque Control mode Direction of rotation -L side -R side Running time -motor -spring return Rotation angle Auxiliary switches Ambient temperature Degree of protection EMC Low Voltage Directive Housing material Weight Maintenance Fastening and wiring 24 V AC + 20% 50/60 Hz 24 V DC +10% 5W 1,5 W 10 VA 15 Nm On-off term. 2 ON: damper rotation counter-clockwise (CCW) term. 2 OFF: damper rotation clockwise (CW) term. 2 ON: damper rotation clockwise (CW) term. 2 OFF: damper rotation counter-clockwise (CCW) 150 s 20 s 95° 2 X SPDT potential free contacts 6A (3) max 250 V AC switching points at 5° and 85° -20...+50° IP66 CE according to 89/336/EEC, 92/31/EEC, 93/68/EEC CE according to 73/23/EEC Aluminium baked varnish 10kg None Terminal block in a EEx e box with mt. 1 cable Electrical diagram 24 V AC / DC SAFE AREA NOTE: AUXILIARY SWITCHES potential free, MAX 230 V AC 85° 5° PE EX AREA 1 2 3 4 PA 5 6 7 8 Terminals box EEx e 1 2 S1 S2 S3 S4 S5 S6 - All electrical wirings must be according to local standards. - Electrical connections by power off only. - EEx e junction box must not be opened under any circumstances when the power is on. - Actuator cables must be installed in a fixed position and protected against damage. - Avoid excessive vibrations. - Before switching-on, check that no other equipment is damaged and make sure that supply voltage corresponds with the specification of the actuator. - Before switching-off check for possible effects on other equipments. ATTENTION: The actuator cannot and is not to be opened to guarantee explosion proof and warranty. For any problem, contact your supplier. Subject to tecnical change without notice. Rev.00 Dimensions EX AF... /U0 150 60 190 35 80 MA 6x10 66 351 130 17 43 MA 6x10 98 43 17 Note: Dimensions are specified in millimeters. Direction of rotation Damper front view Motor front view R Motor R side Spring return direction Spring ccw cw R side ccw L side cw L Spring return direction L side Mounting instructions Direct mount on square shaft, 12 x 12 mm Min 20 mm Max 50 30 mm Damper Shaft 12x12 mm 160 150 166 min 125 196 max STX-1 mounting bracket Damper 291 (251 EX AM...) 337 (297 EX AM...) STX-2 mounting bracket STX-1 STX-2 150 40 4 58 153 88