Copyright 2016 HKW Architects ELECTRICAL SYMBOLS LEGEND S D1 V 1. VOLUME CONTROL - MOUNT 46" AFF. 2. WALL MOUNTED FIXTURE - AS ABOVE - MOUNTING HEIGHT AS PER PLANS. M DUPLEX MICROPHONE OUTLET - MOUNT 18" AFF. EXIT LIGHT - CEILING MOUNTED; WALL MOUNT 7'-6" AFF OR ABOVE DOOR SHADED PORTION INDICATES FACE; WITH DIRECTIONAL ARROW(S) AS INDICATED. FIXTURE TYPE "X" (U.N.O.). M DUPLEX MICROPHONE OUTLET - FLOOR MOUNTED. M MICROPHONE OUTLET - CEILING MOUNTED FOR CORD HUNG DEVICE. COMBINATION EXIT LIGHT WITH EMERGENCY LIGHTING HEADS. FIXTURE TYPE "X1" (U.N.O.). 1. INTERCOM STATION - MOUNT 46" AFF. IC LED,FLUORESCENT OR H.I.D. FIXTURE - AS ABOVE - CEILING MOUNTED OR PENDANT MOUNTED TO HEIGHT INDICATED. C1 SPEAKER - WALL MOUNT 84" AFF. GENERAL CONSTRUCTION NOTES: TC 3. TIME CLOCK 4. 1a,b NL EMERGENCY LIGHT - BATTERY OPERATED - WALL MOUNTED 84" AFF (U.N.O.). FIXTURE TYPE "Y" (U.N.O.). PUSHBUTTON - MOUNT 46" AFF. LIGHT POLE WITH SINGLE HEAD LUMINAIRE. BELL - MOUNT 84" AFF. LIGHT POLE WITH MULTIPLE HEADS (AS INDICATED). VOICE OUTLET - MOUNT 18" AFF; W INDICATES WALL MOUNT 46" AFF, SHADING DENOTES EMERGENCY FIXTURE. DATA OUTLET - MOUNT 18" AFF. 6. FIXTURE CIRCUITRY NOTATION: 1 - CIRCUIT NUMBER TO WHICH FIXTURE IS CONNECTED a,b - LETTER(S) OF SWITCH(ES) CONTROLLING FIXTURE NL - NIGHT LIGHT (UNSWITCHED CIRCUIT) DATA OUTLET - 8" ABOVE COUNTER. 7. 5. FLOOR MOUNTED DATA OUTLET. WIRING DEVICES COMBINATION VOICE & DATA OUTLET - MOUNT 18" AFF. 8. COMBINATION VOICE & DATA OUTLET - 8" ABOVE COUNTER. 9. S SINGLE POLE SWITCH - "a" INDICATES SWITCH LEG - MOUNT 46" AFF. FLOOR MOUNTED COMBINATION VOICE & DATA OUTLET. WIRELESS ACCESS POINT - CEILING MOUNTED, U.N.O. a 10. S DOUBLE POLE WALL SWITCH - AS ABOVE. S THREE-WAY SWITCH - AS ABOVE. TTB TELEPHONE TERMINAL BOARD - 3/4" FIRE RETARDANT PLYWOOD, 4' x 8' (U.N.O.). 11. S FOUR-WAY SWITCH - AS ABOVE. TTC 12. S TELEPHONE TERMINAL CABINET 24" x 36" x 6" (U.N.O.) WITH FIRE RETARDANT PLYWOOD BACK AND HINGED DOOR WITH KEY LOCK. KEY OPERATED SWITCH - AS ABOVE. S SWITCH WITH PILOT LIGHT - AS ABOVE. 2 3 4 K TV P T.V. OUTLET - MOUNT 18" AFF U.N.O. ABBREVIATIONS S WALL BOX TIMER SWITCH. S FAN CONTROL SWITCH. AC ABOVE COUNTER S MANUAL MOTOR STARTER WITH OVERLOAD PROTECTION - MOUNT ON SIDE OF UNIT OR AT 46" AFF. AIC AMP INTERRUPTING CURRENT S OCCUPANCY SENSOR WALL MOUNTED, MOUNT 46" AFF. "2" INDICATES DUAL RELAY. AFC AVAILABLE FAULT CURRENT AFF ABOVE FINISHED FLOOR. T FC M OS 14. S TS TIME SWITCH - MOUNT 60" AFF. PC PHOTOCELL MOUNTED IN WP OUTLET BOX LOCATED ON ROOF, FACING NORTH, (U.N.O.). LC LIGHTING CONTACTOR FOR NUMBER OF CIRCUITS AS INDICATED ON PLAN. OS OCCUPANCY SENSOR, CEILING MOUNTED, "2" INDICATES 2 POLE. EC ELECTRICAL CONTRACTOR JUNCTION BOX OR POINT OF CONNECTION - MOUNT 18" AFF OR AT HEIGHT REQUIRED BY RESPECTIVE EQUIPMENT ITEM MANUFACTURER. EM EMERGENCY J AFI/AFCI DUPLEX RECEPTACLE - MOUNT 18" AFF. DOUBLE DUPLEX RECEPTACLE - AS ABOVE. SINGLE CONVENIENCE RECEPTACLE - AS ABOVE. DUPLEX RECEPTACLE AS ABOVE - SPLIT WIRED, TOP HALF SWITCHED. DUPLEX 8" ABOVE COUNTER OR WALL HUNG LAVATORY. DOUBLE DUPLEX RECEPTACLE 8" ABOVE COUNTER CEILING MOUNTED DUPLEX RECEPTACLE, FLUSH IN CEILING (U.N.O.). FLOOR MOUNTED DUPLEX RECEPTACLE WITH BRASS PLATE AND CARPET FLANGE. SPECIAL PURPOSE OUTLET - MOUNT 18" AFF. TYPE AS REQUIRED BY RESPECTIVE EQUIPMENT MFR. COMBINATION POWER & DATA/VOICE FLOOR BOX OR POKE THRU - "FF" INDICATES FURNITURE FEED. MOTORS AND EQUIPMENT DISCONNECT SWITCH (FUSED OR NON-FUSED AS INDICATED) - MOUNT 60" AFF. 30/20/3 INDICATES SWITCH AMPS/FUSE AMPS/POLES. 30/20/3 T ATS CATV ARC FAULT CIRCUIT INTERRUPTER TYPE DEVICE, (U.N.O.) ELECTRIC WATER COOLER; ROUGH-IN RECEPTACLE INCONSPICUOUSLY; COORDINATE WITH PC EWH ELECTRIC WATER HEATER EX EXISTING FLA FULL LOAD AMPS FPC FIRE PROTECTION CONTRACTOR FSS FUSIBLE SAFETY SWITCH GC GENERAL CONTRACTOR MFR MANUFACTURER MH MOUNTING HEIGHT 30. MIN MINIMUM 31. NF NON-FUSED SWITCH 32. 33. KILOWATT HOUR METER BASE. TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE UPS UNINTERRUPTABLE POWER SUPPLY WP WEATHERPROOF 34. SEISMIC RESTRAINTS FOR ELECTRICAL SYSTEM COMPONENTS (EARTHQUAKE LOAD RESISTANCE) SEISMIC USE GROUP ( II ) HORN OR SPEAKER - MOUNT 80" AFF; V DENOTES COMBINATION AUDIBLE/VISUAL APPLIANCE. (NUMERALS INDICATE CANDELA). FIRE ALARM MAGNETIC DOOR HOLDER. F R INTERFACE RELAY FOR CODE REQUIRED ACTION, OR AS NOTED ON PLANS; SEE SPECIFICATION. F CM CONTROL MODULE FOR CODE REQUIRED ACTION; SEE SPECIFICATION. F MM MONITOR MODULE FOR CODE REQUIRED ACTION, OR AS NOTED ON PLANS; SEE SPECIFICATION. T SPRINKLER TAMPER SWITCH (FURNISHED BY FPC). F SPRINKLER FLOW SWITCH (FURNISHED BY FPC). P SPRINKLER PRESSURE SWITCH (FURNISHED BY FPC). RQE SEISMIC DESIGN CATEGORY ( D ) ANCHORAGE TO FLOORS, ROOFS, ETC. NOT PROVIDED PROVIDED SWAY BRACING NOT PROVIDED PROVIDED LOCATION OF PROFESSIONALLY SEALED ANCHORAGE AND SWAY BRACING DETAILS ON CONST. DOCUMENTS DRAWING NO. OR SPEC. SECTION SUBSEQUENT SUBMITTAL SHOP DRAWINGS COMMENTS SEPARATE PERMIT & PLANS 42. X X 5 N/A, NO EMERGENCY OR STANBY EQUIPMENT IN THE PROJECT X X X X X OTHER EQUIPMENT & SYSTEM COMPONENTS NEEDED FOR CONTINUED OPERATION OF SEISMIC USE GROUP III FACILITIES OR WHOSE FAILURE COULD IMPAIR THEIR CONTINUED OPERATION; N/A, NO SEISMIC USE GROUP III OR IV IN THE PROJECT ELECTRICAL ALTERNATE #1: PROVIDE AN ALTERNATE PRICE ADDER FOR THE FOLLOWING: - REPLACE EXISTING PANEL 102B WITH A NEW 60 POLE, 1 SECTION, 120/208V, 3 PHASE, 4 WIRE, 225A, 10KAIC, MLO PANELBOARD. - PROVIDE TEN (10) ADDITIONAL 20A/1 POLE CIRCUIT BREAKERS AS SPARES. - PROVIDE A 120/208V, 3 PHASE SURGE PROTECTIVE DEVICE AND AN ASSOCIATED 30A/3 POLE CIRCUIT BREAKER FOR THE SPD. - PROVIDE ALL ASSOCIATED INSTALLATION, LABOR AND COORDINATEION FOR THE ABOVE WORK. OTHER GENERAL EQUIPMENT & SYSTEM COMPONENTS; MOTION DETECTOR DOOR CONTACT PANEL BOARD LIGHTING FIXTURES CONDUIT AND WIRING CARD READER/PROX READER REQUEST TO EXIT ES ELECTRIC STRIKE (FURNISHED BY DIVISION 8) EH ELECTRIFIED HARDWARE (FURNISHED BY DIVISION 8) ML MAGNETIC LOCK (FURNISHED BY DIVISION 8) GB GLASS BREAK SENSOR ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR NECESSARY PERMITS, LICENSES, INSPECTIONS AND FEES FROM THE LOCAL AUTHORITIES. CONTRACTOR SHALL BE LICENSED BY LOCAL AND/OR STATE AUTHORITIES HAVING JURISDICTION.. ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), NATIONAL ELECTRICAL CODE (NEC), INTERNATIONAL BUILDING CODE (IBC) AND OTHER APPLICABLE LOCAL, STATE AND NATIONAL CODES. ALL ELECTRICAL MATERIAL USED ON THIS PROJECT SHALL BE "UL" LISTED AND LABELED. THE ENTIRE ELECTRICAL SYSTEM AND ALL ELECTRICAL EQUIPMENT SHALL BE GROUNDED IN STRICT ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND AS SHOWN ON THE DRAWINGS. PROVIDE A GROUND WIRE IN EACH POWER CONDUIT, SIZED PER THE NEC. CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING A COMPLETE SYSTEM PER CONTRACT DRAWINGS AND ENSURING THAT THE SYSTEM IS OPERATIONAL UPON JOB COMPLETION. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH ALL OTHER TRADES AND DISCIPLINES TO AVOID CONFLICTS AND TO VERIFY ALL EQUIPMENT CONNECTIONS. COORDINATE ALL WIRING DEVICE LOCATIONS AND ELEVATIONS INDICATED ON THE PLANS WITH THE OWNER, ARCHITECT AND FINAL FURNITURE/EQUIPMENT LAYOUTS. CONTRACTOR SHALL GUARANTEE ALL LABOR AND MATERIAL INSTALLED OR FURNISHED UNDER THIS CONTRACT FOR A PERIOD OF NOT LESS THAN ONE YEAR AFTER FINAL ACCEPTANCE OF THE BUILDING. MAINTAIN AND VERIFY ELECTRICAL EQUIPMENT CLEARANCES AND WORKING SPACE PER NEC. PROVIDE ELECTRICAL SYSTEMS IDENTIFICATION AS INDICATED IN THE SPECIFICATIONS AND REQUIRED BY THE NEC OR NFPA 70E. IF ANYTHING ON THE PLANS IS NOT IN COMPLIANCE WITH NATIONAL, STATE OR LOCAL CODES, THE ENGINEER SHALL BE ADVISED BY THE ELECTRICAL CONTRACTOR DURING THE BIDDING PROCESS. THERE ARE TO BE NO CHANGES TO THE CONTRACT DOCUMENTS WITHOUT WRITTEN PERMISSION FROM THE ENGINEER. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS FOR NEW WORK, SAFETY, ETC., IN ACCORDANCE WITH ALL AUTHORITIES HAVING JURISDICTION. (I.E. OSHA, NEC, ETC.) THE CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWINGS FOR PHASING AND SCHEDULING OF THIS PROJECT. COORDINATE WITH OWNER'S FIELD REPRESENTATIVE. VERIFY ALL INDICATED DIMENSIONS BY FIELD MEASUREMENTS. NOTIFY ENGINEER OF ANY DISCREPANCIES. PROVIDE ACCESS PANELS OR DOORS WHERE EQUIPMENT OR DEVICES REQUIRED TO BE ACCESSIBLE ARE CONCEALED BEHIND INACCESSIBLE SURFACES. PRIOR TO TURNOVER, THIS CONTRACTOR SHALL REMOVE ALL RUBBISH, DIRT, DEBRIS AND STAINS ON THEIR WORK OR CAUSED BY THEIR WORK AND SHALL THOROUGHLY CLEAN ALL EQUIPMENT, FIXTURES, DEVICES, ETC. CONTRACTOR SHALL REPLACE, TOUCH-UP OR REFINISH THE FACTORY FINISH ON EQUIPMENT, FIXTURES, DEVICES, ETC. MARRED DURING SHIPMENT, INSTALLATION OR CONSTRUCTION. PANELBOARD CIRCUIT BREAKERS SHALL BE EQUIPPED WITH BOLT-ON TYPE BREAKERS, PHENOLIC NAME TAGS AND KEYED LOCK AND LATCH. EACH PANEL SHALL BE PROVIDED WITH TWO KEYS WITH ALL PANELS KEYED ALIKE. ALL CIRCUIT BREAKERS USED TO SWITCH LIGHT FIXTURES SHALL BE TYPE SWD SHALL BE APPROVED FOR THE PURPOSE. ALL CIRCUIT BREAKERS SERVING HVAC EQUIPMENT SHALL BE HACR TYPE. ALL CIRCUITS INDICATED ON THESE DRAWINGS ARE 20A, 1P CIRCUIT BREAKERS IN PANELS UNLESS NOTED OTHERWISE. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER IDENTIFICATION AND LABELING OF ALL CIRCUIT BREAKERS. EACH PANELBOARD SHALL BE EQUIPPED WITH A TYPE WRITTEN CIRCUIT DIRECTORY. ALL EXISTING PANELBOARDS THAT HAVE CIRCUITS ALTERED SHALL HAVE A NEW TYPE WRITTEN CIRCUIT DIRECTORY SHOWING CIRCUIT REVISIONS AND EXISTING CIRCUIT CONDITIONS ON THE NEW DIRECTORY. MINIMUM WIRE SIZE SHALL BE #12 AWG UNLESS OTHERWISE NOTED. MINIMUM CONDUIT SIZE SHALL BE 1/2" UNLESS OTHERWISE NOTED. ALL CONDUIT IN SLABS OR EXTERIOR TO BUILDING SHALL BE MINIMUM 1". PROVIDE A NYLON/POLY PULL CORD IN ALL EMPTY CONDUITS. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL COPPER CONDUCTORS TYPE THHN OR THWN FOR ALL INTERIOR BUILDING WIRE. FOR EXTERIOR FEEDERS AND BRANCH CIRCUITS PROVIDE ALL COPPER CONDUCTORS TYPE XHHW-2. VOLTAGE DROP MINIMUM WIRE SIZING (20A CIRCUIT) USE: 120V CIRCUIT OVER 100' SHALL BE #10 MINIMUM; 120V CIRCUIT OVER 175' SHALL BE #8 MINIMUM; 208V CIRCUIT OVER 200' SHALL BE #10 MINIMUM; 277V CIRCUIT OVER 200' SHALL BE #10 MINIMUM. MINIMUM WIRE SIZE FOR ANY 20A BRANCH CIRCUIT SHALL BE #12. FURTHERMORE, CONSIDER ALL DERATING OF CONDUCTORS AS REQUIRED IN ACCORDANCE WITH THE APPLICABLE NEC. ELECTRICAL CONTRACTOR SHALL HAVE THE OPTION OF GROUPING HOME RUNS IN ONE CONDUIT, PER THE REQUIREMENTS OF SECTION 310 OF THE NATIONAL ELECTRICAL CODE. NO MORE THAN FOUR (4) CIRCUITS SHALL BE ALLOWED TO BE GROUPED AND INSTALLED IN A SINGLE JUNCTION BOX. EC SHALL BE RESPONSIBLE FOR INCREASING CONDUCTOR SIZE AND DERATING. HOME RUNS WITH MORE THAN THREE CIRCUITS SHALL BE #10 AWG. CONDUCTOR MINIMUM. PROVIDE DEDICATED NEUTRALS FOR EACH PHASE CONDUCTOR AND CONSIDER THEM AS A CURRENT CARRYING CONDUCTOR FOR DERATING. ALL HOME RUNS SHALL BE IN EMT CONDUIT. MC CABLE IS PERMITTED ABOVE CEILINGS FROM HOMERUNS TO FIXTURES AND WIRING DEVICES WITHIN WALLS AND FURRED COLUMNS. REFER TO ELECTRICAL SPECIFICATIONS FOR MORE DETAILED INFORMATION. ONLY PVC CONDUIT SHALL BE PERMITTED IN CONCRETE SLAB, EXCEPT FOR GRS ELLS. WHEN SAW CUTTING FLOOR IS REQUIRED, CONTRACTOR SHALL LIMIT DEPTH TO A MINIMUM. ROUTE NEW CONDUITS BELOW OR ABOVE EXISTING CONDUITS, WATER PIPES, ETC. CONDUIT SHALL HAVE A MINIMUM OF 1'' OF CONCRETE COVER. CONTRACTOR SHALL XRAY FLOOR SLAB PRIOR TO ANY SAW CUTTING. ELECTRICAL CONTRACTOR SHALL ARRANGE WITH THE ELECTRIC, CATV AND TELEPHONE UTILITY COMPANIES FOR INCOMING SERVICE REQUIREMENTS FROM LANDLORD DEMARC AND INCLUDE ALL COSTS IN BASE BID. HEATING, VENTILATING, AIR CONDITIONING EQUIPMENT AND PLUMBING EQUIPMENT ALONG WITH ALL OTHER MISCELLANEOUS EQUIPMENT, MOTORS, AND KITCHEN EQUIPMENT SHALL BE POWERED AS CALLED OUT ON EQUIPMENT PROVIDER'S SCHEDULES UNLESS OTHERWISE NOTED. EC SHALL PROVIDE DISCONNECTING MEANS UNLESS SPECIFICALLY NOTED ON EQUIPMENT PROVIDER'S SCHEDULE. SUPPORT ALL CONDUITS FROM STRUCTURAL WALLS, SLABS, MEMBERS AND ROOF JOISTS. DO NOT SUPPORT CONDUITS FROM CEILING TIE WIRES, DUCTWORK, PIPING, ROOF DECK OR OTHER NON-STRUCTURAL MEMBERS. SUPPORTING OF ELECTRICAL CONDUITS: THE INDIVIDUAL BRANCH CIRCUIT CONDUIT AND ASSOCIATED 4'' X 4'' JUNCTION BOXES MAY BE SUPPORTED FROM FLOOR/ROOF JOISTS. ALL LARGER FEEDER CONDUITS AND/OR CLUSTER OR GROUPS OF BRANCH CIRCUIT CONDUITS SHALL BE SUPPORTED ON STEEL TRAPEZE WITH STEEL CHANNEL ATTACHED TO STEEL OR WOOD JOIST/BEAMS WITH PROPER ATTACHMENTS. NO SUPPORT SHALL BE ATTACHED TO THE ROOF DECK (NO EXCEPTIONS). HANG CONDUIT FROM TOP CHORD OF BAR JOIST WHEN ATTACHING HOME RUNS TO JOIST. INTERIOR AND EXTERIOR LIGHT FIXTURES SHALL BE FURNISHED AND INSTALLED AS SHOWN ON THE DRAWINGS AND AS CALLED OUT IN THE LIGHTING FIXTURE SCHEDULE. ALL WIRING DEVICES SHALL BE FLUSH MOUNTED, UNLESS NOTED OTHERWISE. ALL CONDUIT SHALL BE RUN WITHIN WALL CAVITIES, BELOW FLOOR AND ABOVE CEILINGS. SURFACE MOUNTED ELECTRICAL WORK SHALL NOT BE USED UNLESS SPECIFICALLY NOTED ON THE PLANS. ALL WALL AND CEILING FIXTURES AND DEVICES SHALL BE INDEPENDENTLY AND SECURELY MOUNTED SO THEY ARE NOT DEPENDENT ON CEILING FINISH FOR SUPPORT AND CAN NOT BE ROTATED OR DISPLACED. FIXTURES AND DEVICES MOUNTED IN SUSPENDED ACOUSTICAL CEILING TILE SHALL HAVE CHANNEL SUPPORTS ACROSS THE MAIN GRID RUNNERS OR GRID SUPPORTS SECURELY ANCHORED SO AS NOT TO CAUSE TILE TO SAG OR SO FIXTURE OR DEVICE CAN NOT BE LIFTED, ROTATED OR DISPLACED. ELECTRICAL LIGHT FIXTURES, MECHANICAL AIR DEVICES, FIRE SPRINKLERS, AND SMOKE DETECTORS IN CEILING: ALL SUBS NEED TO TAKE OTHER DISCIPLINES INTO CONSIDERATION BEFORE STARTING THEIR WORK. ALL ITEMS THAT NEED TO BE MOVED WILL BE MOVED AT THE SUB'S EXPENSE. FIRE SPRINKLERS MUST BE LOCATED A MINIMUM OF 30 INCHES FROM ANY SURFACE MOUNTED LIGHT. SMOKE DETECTORS MUST BE MOUNTED NO CLOSER THAN 3 FEET OF AN AIR DEVICE OR CEILING FAN. FIRE SPRINKLERS, LIGHT FIXTURES, SMOKE DETECTORS, AND AIR DEVICES ALL TO BE CENTERED DOWN THE HALLWAYS. ELECTRICAL, MECHANICAL, FIRE SPRINKLER, AND LOW VOLTAGE SUB CONTRACTOR MUST MEET AND DECIDE BEFORE ANYONE STARTS, WHERE LOCATION OF THESE ITEMS WILL BE LOCATED. IF ITEM NEEDS TO BE MOVED, IT WILL BE AT THE EXPENSE OF THE SUB CONTRACTOR. COORDINATE WITH ARCHITECT'S REFLECTED CEILING PLAN. ALL OPENINGS IN FIRE AND/OR SMOKE RATED WALLS, FLOORS, AND PARTITIONS FOR CONDUITS SHALL BE SEALED WITH RED FIRE RESISTANT FOAM OR PUTTY TO MAINTAIN THE FIRE AND/OR SMOKE RATING. ALL OPENINGS IN FIRE RATED AND/OR SMOKE WALLS, FLOORS, AND PARTITIONS FOR CABLING SHALL BE SEALED WITH WIREMOLD FLAMESTOPPER, STI EZ-PATH, HILTI SPEED SLEEVE OR EQUIVALENT. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHT FIXTURES, DIMENSIONAL LOCATION OF FIXTURES IN DRYWALL CEILING, ETC. LOCATION OF FLOOR BOXES AND RECEPTACLES, INCLUDING MOUNTING HEIGHTS. ALL RECEPTACLES AND COVER PLATE COLORS SHALL BE APPROVED BY ARCHITECT OWNER RESERVES THE RIGHT TO RELOCATE ANY LIGHT FIXTURE, RECEPTACLE, ETC., BEFORE BEING INSTALLED 10'-0'' FROM LOCATION AS SHOWN ON PLANS AT NO ADDITIONAL EXPENSE TO THE OWNER. OUTLETS IN OFFICES SHALL HAVE THEIR WALL LOCATIONS COORDINATED WITH FINAL FURNITURE LAYOUT. GROUP POWER AND COMMUNICATION OUTLETS SIDE BY SIDE AT SAME HEIGHT. NO CONDUIT OR CABLES SHALL BE INSTALLED EXPOSED IN FINISHED AREA. NON-CEILING AREA CONDUITS SHALL BE INSTALLED EXPOSED IN A NEAT WORKMAN LIKE MANNER AND BE PAINTED TO MATCH ADJACENT FINISHES. ALL MATERIALS, DEVICES, FIXTURES, ETC., THAT ARE REQUIRED FOR THIS PROJECT ARE TO BE FURNISHED AND INSTALLED BY THE EC, UNLESS SPECIFICALLY INDICATED TO BE FURNISHED AND OR INSTALLED BY OTHERS. TELEPHONE, IT, AUDIO, VIDEO AND SECURITY CABLE WIRING WILL BE PROVIDED BY OWNERS VENDOR. EC SHALL COORDINATE AND PROVIDE ALL ROUGH-IN'S AS REQUIRED. LOW VOLTAGE DEVICES HAVE BEEN SHOWN ON THE PLANS FOR REFERENCE PURPOSES ONLY. ALL LOW VOLTAGE CABLING SHALL BE ROUTED IN CONDUIT FROM DEVICE/JUNCTION BOX TO ABOVE AN ACCESSIBLE CEILING OR IN ATTIC SPACE; 1" EMT MINIMUM. EC SHALL PROVIDE J-HOOKS AS REQUIRED, NO MORE THAN 60" O.C. ALL SIGNAL AND CONTROL CABLES SHALL BE MINIMUM #18 STRANDED COPPER, UNLESS NOTED OTHERWISE. ALL CONNECTIONS AND SPLICES TO BE MADE BY USE OF ''STA-KON'' CONNECTORS AND TERMINAL STRIPS. TYPICAL SEISMIC DETAILS ARE PROVIDED ON THE DRAWINGS FOR REFERENCE ONLY. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO THE OWNER'S ENGINEER FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO THE PLAN REVIEWER. SHOP DRAWINGS SHALL SHOW ALL EQUIPMENT ANCHORAGE TO WALLS/CEILINGS/FLOORS AND SHALL INCLUDE SIZE OF SEISMIC ANCHOR BOLTS USED FOR EACH SYSTEM. CONTRACTOR SHALL PROVIDE CALCULATIONS, DETAILS, ETC. - PREPARED BY, SIGNED AND SEALED BY A LICENSED STRUCTURAL ENGINEER. REFER TO SPECIFICATIONS. 1,2,8,9 1 INTRUSION ALARM PANEL KEY PAD 40. 41. EMERGENCY OR STANDBY EQUIPMENT & SYSTEM COMPONENTS; EMERGENCY LIGHTING FIXTURES EXIT SIGNS 38. 39. FIRE PROTECTION, DETECTION & ALARM EQUIPMENT & SYSTEM COMPONENTS; FIRE ALARM WIRING F DH CR LISTING OF EQUIPMENT & SYSTEM COMPONENTS VISUAL FLASHER - MOUNT 80" AFF TO BOTTOM OF FLASHER; (NUMERALS INDICATE CANDELA). EXTERIOR FA BELL - MOUNT 90" AFF. C 36. 37. INTRUSION ALARM SYSTEM The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. 35. FIRE ALARM POWER SUPPLY - MOUNTED 72" A.F.F. HEAT DETECTOR - CEILING MOUNTED (U.N.O.). MD 19. MECHANICAL CONTRACTOR TEMPERATURE CONTROL CONTRACTOR H K 18. 27. TCC DUCT MOUNTED SMOKE DETECTOR'S REMOTE ANNUNCIATOR LAMP AND TEST SWITCH-MOUNT ON CEILING, (U.N.O.). IAP 17. 26. DRY-TYPE TRANSFORMER. F A F 16. 24. 25. DUCT MOUNTED SMOKE DETECTOR WITH SAMPLING TUBES. V 30 15. MC RAINTIGHT SMOKE DETECTOR - CEILING MOUNTED. F 13. 14. 29. RT SD 15 12. MAXIMUM EXISTING BRANCH CIRCUIT PANELBOARD. MANUAL PULL STATION - MOUNT 46" AFF. F 11. MAX PLUMBING CONTRACTOR F SD 10. 23. DACT DIGITAL ALARM COMMUNICATOR TRANSMITTER FAPS 8. 9. 28. PC FIRE ALARM ANNUNCIATOR PANEL - MOUNT TOP 72" AFF. 7. GROUND FAULT CIRCUIT INTERRUPTER TYPE DEVICE, (U.N.O.) GFI/GFCI NEW BRANCH CIRCUIT PANELBOARD - MOUNT TOP 78" AFF. FAAP 6. 22. EWC NOT TO SCALE FIRE ALARM CONTROL PANEL - MOUNT TOP 72" AFF. 5. 21. CABLE TELEVISION NTS FACP 3. 4. AUTOMATIC TRANSFER SWITCH ELECTRIC MOTOR. FIRE ALARM SYSTEM 2. 20. DIMMER SWITCH - AS ABOVE, 1000 WATT RATING OR 0-10V AS REQUIRED. MOUNT 46" A.F.F. D 13. THE OWNER INTENDS TO VACATE SPECIFIC AREAS OF WORK BEFORE DEMOLITION BEGINS. ALL OTHER AREAS SHALL REMAIN OCCUPIED AND IN ACTIVE USE. UTILITIES AND SERVICES TO EXISTING ACTIVE AREAS SHALL NOT BE INTERRUPTED WITHOUT THE OWNER'S APPROVAL AS TO THE TIME AND DURATION. THE OWNER WILL CONTINUE TO OCCUPY THE REST OF THE EXISTING FACILITIES THROUGHOUT THE CONSTRUCTION OPERATIONS. THE ELECTRICAL CONTRACTOR SHALL SO ORGANIZE HIS WORK AS TO CAUSE A MINIMUM OF UTILITY INTERRUPTIONS, WHICH SHALL BE SCHEDULED AT THE CONVENIENCE OF THE OWNER. ALL ELECTRICAL EQUIPMENT, LIGHTING FIXTURES, SWITCHES, RECEPTACLES, SPECIAL OUTLETS, ETC., WHICH ARE NOTED TO BE DEMOLISHED, OR ARE SHOWN WITH DASHED LINE SYMBOLS ON THE DEMOLITION PLANS, SHALL BE REMOVED. ASSOCIATED WIRING AND CONDUIT SHALL BE REMOVED BACK TO THE SOURCE OR EXISTING UPSTREAM DEVICE TO REMAIN AND MADE SAFE. REMOVE EQUIPMENT, FIXTURES, DEVICES AND OUTLETS AS SPECIFIED AND SHOWN ON DRAWINGS, AND AS MAY BECOME NECESSARY BECAUSE OF EXISTING FIELD CONDITIONS. EXAMINE ALL EXISTING WALLS AND CEILING DESIGNATED FOR REMOVAL TO DETERMINE THE CONDUIT AND WIRING THAT WILL REQUIRE REMOVAL. FOR EXISTING ELECTRICAL DEVICES IN WALLS TO BE REMOVED, DISCONNECT POWER, REMOVE CONDUCTORS AND CAP CONDUIT BELOW FLOOR OR ABOVE CEILING AS REQUIRED. DEVICES ARE TO BE REMOVED ALONG WITH WALL BY GENERAL CONTRACTOR. FOR EXISTING ELECTRICAL EQUIPMENT, FIXTURES AND DEVICES TO BE REMOVED FROM WALLS WHICH REMAIN, DISCONNECT POWER, REMOVE CONDUCTORS, REMOVE THE ELECTRICAL ITEM, AND PATCH AND FINISH THE SURFACE AS REQUIRED TO MATCH THE EXISTING, OR MAKE READY FOR NEW WALL FINISH. PROVIDE BLANK PLATES WHERE NOTED OR REQUIRED. EXISTING RECEPTACLES, DEVICES, ETC. TO REMAIN ARE DENOTED BY THIN SOLID LINE OR MAY NOT BE INDICATED AT ALL. THESE DEVICES SHALL BE EXTENDED TO BE FLUSH WITH NEW FINISH ON EXISTING WALL WHERE REQUIRED. MAINTAIN CIRCUIT CONTINUITY TO ALL EQUIPMENT, FIXTURES, DEVICES, ETC., TO REMAIN IN USE WHETHER NOTED ON THE PLANS OR NOT. FIELD VERIFY EXISTING ITEMS TO REMAIN IN USE. WIRING FOR EXISTING CIRCUITS WHICH ARE PARTIALLY ABANDONED SHALL BE RECONNECTED BY THE ELECTRICAL CONTRACTOR TO SERVICE THE REMAINING OUTLETS ON THE CIRCUIT. ALL WIRING FOR A CIRCUIT WHICH IS TO BE REMOVED SHALL BE REMOVED BACK TO THE PANEL WHICH SUPPLIED THE CIRCUIT. EXISTING CONDUIT & CONDUCTORS MAY BE REUSED WHERE FEASIBLE. ALL UNUSED CONDUIT MADE EMPTY BY THIS DEMOLITION SHALL BE REMOVED BY THE ELECTRICAL CONTRACTOR. WHERE CONDUITS EXTENDING OUT OF THE FLOOR ARE TO BE REMOVED, CUT THE CONDUIT OFF 1/2" BELOW THE FLOOR LINE AND PATCH. ALL ACTIVE CIRCUITING THAT RUNS THROUGH THIS SPACE, ORIGINATING AND/OR TERMINATING IN OTHER SPACES, SHALL REMAIN IN PLACE. COORDINATE WITH NEW CEILING WORK FOR RAISED CEILING WHICH MAY REQUIRE CIRCUITING RELOCATION. ALL UNUSED TELEPHONE AND DATA CABLES SHALL BE REMOVED. ANY OTHER UNUSED LOW VOLTAGE SYSTEMS CABLES SHALL ALSO BE REMOVED. ALL EXISTING EQUIPMENT, LIGHTING FIXTURES, WIRING DEVICES, AND MATERIALS TO BE REMOVED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES AND PROPERLY DISPOSED OF IN ACCORDANCE WITH AUTHORITIES HAVING JURISDICTION, UNLESS OTHERWISE NOTED. ALL ITEMS NOTED THAT THE OWNER CHOOSES TO KEEP SHALL BE TRANSFERRED TO THEIR STORAGE AREA BY THE ELECTRICAL CONTRACTOR. FOR ALL EXISTING ELECTRICAL WIRING DEVICES, TELEPHONE, DATA ETC., CONTRACTOR SHALL REMOVE/REINSTALL COVERPLATES AS REQUIRED TO ALLOW FOR NEW FINISHES. INFORMATION ON THE EXISTING CONDITIONS PLANS ARE COMPILED FROM EXISTING DRAWINGS AND CASUAL FIELD OBSERVATIONS AND SHALL BE CONSIDERED APPROXIMATE ONLY. VERIFICATION OF ALL EQUIPMENT, WIRING DEVICES AND FIXTURES, EITHER SHOWN OR NOT SHOWN ON THESE PLANS, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. NOTIFY ENGINEER IMMEDIATELY IF DISCREPANCIES EXIST. X X X X X X X 3,8,9 1,4 5,6,7 IT IS THE BASIC INTENET OF THIS CODE BLOCK TO DECLARE WHETHER OR NOT ANCHORAGE AND SWAY BRACING IS REQUIRED ON THE PROJECT. IF SO, TO DECLARE WHETHER OR NOT THE DETAILS ARE SHOWN ON THE PLANS OR WILL BE SHOWN ON A SUBSEQUENT SUBMISSION. IF SEISMIC RESTRAINT OF A COMPONENT IS NOT REQUIRED BY CODE THIS SHOULD BE STATED IN COMMENTS. IF SEISMIC RESTRAINT, WHICH IS NOT REQUIRED BY CODE, IS BEING PROVIDED DUE TO OWNER/DESIGNER REQUIREMENTS THIS SHOULD ALSO BE STATED IN THE COMMENTS. SHOP DRAWINGS NEED TO BE SUBMITTED TO THE COUNTY A MINIMUM OF TWO WEEKS PRIOR TO THE PLANNED INSTALLATION TO ALLOW FOR PLAN REVIEW AND DISTRIBUTION TO THE INSPECTOR. ADDITIONAL TIME MAY BE NEEDED IF SUCH SUBMISSIONS ARE DEFICIENT. VIDEO SURVEILLANCE CAMERA A DURESS/HOLD UP ALARM CIRCUITRY DESIGNATIONS BRANCH CIRCUITRY. CONCEALED IN WALLS OR ABOVE CEILINGS. ARROW INDICATES HOME RUN TO PANEL. SHORT SLASH MARKS INDICATE "HOT" WIRES, LONG SLASH MARK INDICATES "NEUTRAL" WIRE, LONG SLASH WITH SOLID CIRCLE INDICATES GREEN GROUNDING CONDUCTOR. BRANCH CIRCUITRY AS ABOVE, CONCEALED IN FLOOR SLAB OR UNDERGROUND. BRANCH CIRCUITRY AS ABOVE, EXPOSED ON WALLS OR STRUCTURE. 1. LIGHT FIXTURES LESS THAN 20 POUNDS POWERED WITH FLEXIBLE CABLE LESS THAN 3 FEET, FIXTURE SHALL BE MECHANICALLY ATTATCHED TO CEILING GRID. 2. PENDANT TYPE FIXTURES DO NOT REQUIRE SWAY BRACING WHEN IT CAN SWING AT AN ANGLE OF 45° FROM VERTICAL WITHOUT IMPACTING OTHER COMPONENTS. 3. TABLE 4.4, EXCEPTION FOR IP=1.0, WEIGHT LESS THAN 400 POUNDS. 4. TABLE 4.4, EXCEPTION FOR IP=1.0, WEIGHT LESS THAN 20 POUNDS. 5. TABLE 4.4, EXCEPTION FOR IP=1.0, WEIGHT 5LBS/FT OR LESS. 6. FLEXIBLE CONNECTION REQUIRED BETWEEN EQUIPMENT AND COMPONENTS IF INSTALLATION OTHER THAN MOUNTED TO WALLS AND FLOORS. 7. TABLE 4.4, ITEM 2, D, RIGID STEEL IMC CONDUIT < 1-1/2 INCHES IN DIAMETER, AND EMT OR ALUMINUM CONDUIT < 2 INCHES IN DIAMETER. 8. TYPICAL SEISMIC DETAILS ARE PROVIDED ON THE DRAWINGS FOR REFERENCE ONLY. SHOP DRAWINGS ARE REQUIRED. 9. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO THE PLAN REVIEWER. 10. ELECTRICAL EQUIPMENT AND COMPONENTS IN SEISMIC DESIGN CATEGORY 'C' WITH Ip = 1.0 ARE EXEMPT FROM SEISMIC RESTRAINTS PER ASCE-7,13.1.4. CIRCUITRY UP - CIRCUITRY DOWN. MISCELLANEOUS SEISMIC RESTRAINTS FOR ELECTRICAL SYSTEM COMPONENTS NO SCALE XXX X-X MECHANICAL EQUIPMENT ITEM IDENTIFICATION PER EQUIPMENT SCHEDULE ON MECHANICAL DRAWINGS. ELECTRICAL SHEET LIST Sheet Number E0.1 E0.2 E0.3 E1.1 E2.1 Sheet Name ELECTRICAL SYMBOLS, ABBREVIATIONS & GENERAL NOTES ELECTRICAL PANEL SCHEDULES ELECTRICAL DETAILS ELECTRICAL LIGHTING PLAN ELECTRICAL POWER & SYSTEMS PLAN MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 314.361.0000 ph 314.361.9191 fax IOWA 1000 Melrose Avenue Iowa City, IA 52246 319.343.7055 ph hkwarchitects.com 18207 Edison Avenue Chesterfield, M0 63005 636.530.7770 ph 636.530.7877 fax Bid Set LUMINAIRE - AS ABOVE - WALL MOUNTED 84" AFF (U.N.O). GENERAL DEMOLITION NOTES: 912 Meramec Station Road, Valley Park, MO 63021 BB2 SPEAKER - CEILING MOUNTED. S PNC Valley Park LUMINAIRE - CEILING MOUNTED. ALPHA-NUMERIC DESIGNATION DENOTES TYPE; SEE LIGHTING FIXTURE SCHEDULE FOR DESCRIPTION. PNC Bank AA3 AUXILIARY SYSTEMS Revision Schedule No SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION LIGHTING FIXTURES Date Description April 11, 2016 16.008.00 ELECTRICAL SYMBOLS, ABBREVIATIONS & GENERAL NOTES E0.1 Copyright 2016 HKW Architects Branch Panel: 102B Location: Elec/Data 105 Supply From: Mounting: Surface Enclosure: Type 1 Volts: 120/208 Wye Phases: 3 Wires: 4 A.I.C. Rating: Mains Type: MLO Mains Rating: 225 A MCB Rating: Notes: MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 314.361.0000 ph 314.361.9191 fax CKT NOTES 1 --2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 CKT A 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Trip Poles RTU 35 A 3 ------Vestibule, Lobby, and Concierge Lighting 20 A 1 Corridor, Janitor, Restrooms Lighting,... 20 A 1 Off-Stage, Offices, Break, and Cash... 20 A 1 Emergency Lighting 20 A 1 General Receptacles 20 A 1 Exterior PNC Sign 20 A 1 Receptacle - VESTIBULE 20 A 1 Receptacle - OFF STAGE 20 A 1 Receptacle - CONCIERGE 20 A 1 MDF Printer - CONCIERGE 20 A 1 RECEPTACLE - ICI PRINTER 20 A 1 Receptacle - TELLER/CONCIERGE 20 A 1 Receptacle - TELLER/CONCIERGE 20 A 1 Receptacle - TELLER/CONCIERGE 20 A 1 Receptacle - TELLER/CONCIERGE 20 A 1 Receptacle - CASH ROOM 20 A 1 Receptacle - CASH ROOM 20 A 1 Receptacle - CASH ROOM 20 A 1 Total Load: Total Amps: B C A B C Circuit Description 3360 VA 1280 VA 3360 VA 1280 VA 3360 VA 894 VA 1280 VA 1900 VA 714 VA 400 VA 630 VA 501 VA 360 VA 500 VA 900 VA 1440 VA 200 VA 360 VA 900 VA 1740 VA 720 VA 1200 VA 720 VA 500 VA 1000 VA 720 VA 360 VA 180 VA 180 VA 360 VA 2500 VA 360 VA 180 VA 180 VA 360 VA 360 VA 2000 VA 2000 VA 360 VA 14835 VA 125 A 2100 VA 860 VA 13374 VA 111 A 0 VA 14350 VA 121 A CKT Poles 3 --1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 -1 1 Trip 40 A --20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 25 A -30 A 20 A Circuit Description RTU --Receptacle TOILET/COUPON Receptacle - EWC Receptacle - IT Receptacle for Diebold Receptacle - OFFICE Receptacle - OFFICE Receptacle - BREAKROOM/JANITOR Microwave - BREAKROOM Counter Refrigerator - BREAKROOM Receptacle - OFF STAGE & DISCOVER MICR Printer - CONCIERGE Counter Receptacle - CASH/SECURITY IT RACK Receptacle IT RACK Receptacle EH-1 -- 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 Water Heater 40 Spare 42 CKT NOTES 1 --2 2 2 2 2 2 2 2 2 2 2 3 3,4 3,4 3,5 -3,5 3 IOWA 1000 Melrose Avenue Iowa City, IA 52246 319.343.7055 ph hkwarchitects.com 18207 Edison Avenue Chesterfield, M0 63005 636.530.7770 ph 636.530.7877 fax Legend: Load Classification Lighting Power Electric Heat Other Receptacle Connected Load 2145 VA 180 VA 4000 VA 2900 VA 19420 VA Demand Factor 100.00% 100.00% 100.00% 100.00% 75.75% Estimated Demand 2145 VA 180 VA 4000 VA 2900 VA 14710 VA Panel Totals Total Conn. Load: Total Est. Demand: Total Conn. Current: Total Est. Demand Current: 42565 VA 37855 VA 118 A 105 A Notes: ELECTRICAL PANELBOARD NOTES: Bid Set PNC Bank NOTE: EXISTING PANEL SCHEDULE IS NOT LABELED WELL AND ASSUMPTIONS HAVE BEEN MADE FOR RE-USE OF CIRCUITS. FIELD VERIFY ALL AVAILABLE CIRCUITS AFTER DEMOLITION AND MODIFY CIRCUITING AS REQUIRED. NOTE CHANGES ON AS BUILT DRAWINGS. 912 Meramec Station Road, Valley Park, MO 63021 EXISTING LOAD TO REMAIN. FIELD VERIFY PANEL LABELING IS ACCURATE PRIOR TO WORK. EXISTING LOAD TO BE REMOVED. FIELD VERIFY LOAD IS DEMOLISHED AND RE-USE CIRCUIT BREAKER. NEW BREAKER IN EXISTING SPACE. VERIFY WITH OWNER'S IT REP PRIOR TO ORDERING. VERIFY SIZE WITH MC/PC PRIOR TO ORDERING. PNC Valley Park 1. 2. 3. 4. 5. Revision Schedule SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. No Date Description April 11, 2016 16.008.00 ELECTRICAL PANEL SCHEDULES E0.2 Copyright 2016 HKW Architects MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 314.361.0000 ph 314.361.9191 fax IOWA 1000 Melrose Avenue Iowa City, IA 52246 319.343.7055 ph hkwarchitects.com 18207 Edison Avenue Chesterfield, M0 63005 636.530.7770 ph 636.530.7877 fax EXPANSION ANCHOR 1/2"x1-1/4" HEX HEAD CAP SCREWS AND N225WO NUTS 5/8" BOLT B-LINE, B22 CHANNEL LONGITUDINAL OR TRANSVERSE BRACE (9'-4" MAX LENGTH) NO SCALE INNER NEOPRENE BUSHING TYPE "PB" EQUIPMENT SUPPORT LEG SEISMIC ANCHOR BOLT TYPE "SAB" STEEL WASHER NEOPRENE BUSHING "TYPE Z" CONCRETE FLOOR FIELD TRIM BUSHING TO MATCH HOLE DEPTH (2) SEISMIC CABLE BRACES PER CABLE ANCHORED TO STRUCTURE ABOVE OUTER STEEL SLEEVE SWIVEL CONNECTION OVERSIZED HOLE OUTSIDE NEOPRENE ELEMENT SEISMIC ANCHOR SLACK 1/8" GAL. STEEL AIRCRAFT CABLE DESIGNER NOTES: 1. REFERENCE SPECIFICATION SECTION 260025, "SEISMIC RESTRAINTS" ARTICLE FOR ADDITIONAL INFORMATION. ELONGATED INNER STEEL SLEEVE DESIGNER NOTES: 1. THIS IS BASED ON MASON INDUSTRIES INC. TYPE "SCB" BRACE. 2. THIS IS BASED ON MASON INDUSTRIES INC. TYPE "SG" NEOPRENE ISOLATOR. The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. 3. NORMALLY USED ON FLOOR MOUNTED EQUIPMENT WHICH GENERATE IT'S OWN VIBRATION. 7 SEISMIC ISOLATOR TYPE "Z1" NO SCALE 2. REFERENCE SPECIFICATIONS 260025, "VIBRATION AND SEISMIC CONTROL" FOR ADDITIONAL INFORMATION. DOES NOT 3. USE THIS DETAIL IN CONJUNCTION WITH TRAPEZE MOUNTED SEISMIC SUPPORT. 6 SEISMIC SWAY BRACING CABLE ANCHOR NO SCALE GENERAL FASTENED TO STRUCTURE ABOVE MOUNT C-BAR LIGHT FIXTURE SUPPORT CHANNEL ON T-BAR CEILING GRID SUPPORT BY G.C. BACK OF STEEL PANEL CONCRETE WALL MOUNTED EQUIPMENT SEISMIC ANCHORAGE MOUNT ADJUSTABLE MOUNTING BRACKETS TO LIGHT FIXTURE AND C-CHANNEL RECESSED TROFFER CONDUITS: ADJUSTABLE MOUNTING BRACKET T-BAR CEILING GRID SHEET METAL SCREWC-BAR TO T-BAR PLUS SAME ON DIAGONAL INSERT #2 TAPPING SCREWS THRU CLAMP AND TEE BAR (2 PER CLAMP) CADDY SFCLT SEISMIC FIXTURE CLAMP WITH SELF TAPPING SCREWS ONE (1) AT EACH CORNER (TYP. OF 4) NOTES: 1. BASED ON MASON INDUSTRIES INC. TYPE "PB" NEOPRENE BUSHING. NO SCALE SEISMIC SUPPORTED TEE BAR CEILING 1. NO BRACING IS REQUIRED IF THE TOP OF THE CONDUIT IS SUSPENDED 12" OR LESS FROM THE SUPPORTING STRUCTURAL MEMBER. 2. ATTACHMENT TO STRUCTURAL MEMBERS SHALL USE DEVICES INCLUDED IN FEDERAL SPECIFICATION WW--H-171 (MSS SP-58) OR BE BOLTED/WELDED AS APPROVED BY THE ENGINEER. BRACES SHALL BE CONNECTED TO THE HANGERS/SUPPORTS FOR CONDUIT. 3. SEE THE SPECIFICATIONS FOR REQUIRED STRENGTH OF BRACING. 4. LATERAL SEISMIC FORCE SHALL BE CONSIDERED TO ACT CONCURRENTLY WITH THE DEAD LOAD. THE SLENDERNESS RATIO (l/r) OF BRACES SHALL NOT EXCEED 200, WHERE (l) IS THE LENGTH OF THE BRACE AND (r) IS THE LEAST RADIUS OF GYRATION, BOTH IN INCHES. INSIDE NEOPRENE ELEMENT 5 12GA. SLACK WIRE OR PENCIL ROD UP TO STRUCTURE 1. BRACE ALL 2" AND LARGER. 2. TRANSVERSE AND VERTICAL BRACING SHALL OCCUR AT 40' INTERVALS, MAXIMUM. LONGITUDINAL BRACING SHALL OCCUR AT 80' INTERVALS, MAXIMUM. 3. AT RISERS, WHEREVER POSSIBLE, SUPPORT THE WEIGHT OF THE RISER AT A POINT OR POINTS ABOVE THE CENTER OF GRAVITY OF THE RISER. STEEL DISK No 4 NOTES FOR SEISMIC BRACING NO SCALE 3 RECESSED MOUNTED FIXTURE SEISMIC SUPPORT "SS3B" NO SCALE 1 RECESSED MOUNTED FIXTURE SEISMIC SUPPORT "SS4" NO SCALE SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION SEISMIC ANCHOR BOLT Revision Schedule CEILING GRID SUPPORT BY G.C. SEISMIC ANCHOR AND ANCHOR BOLT Bid Set ATTACHMENT - LATERAL BRACING TO MASONRY OR CONCRETE PNC Valley Park 2 PNC Bank 1 912 Meramec Station Road, Valley Park, MO 63021 1 Date Description April 11, 2016 16.008.00 ELECTRICAL DETAILS E0.3 Copyright 2016 HKW Architects ELECTRICAL GENERAL NOTES: 1. 2. 3. Lighting Fixture Schedule Lamp Details Lamp Voltage Lamp Type 120V LED, 3500K INCLUDED Type Mark Manufacturer Catalog No. A CREE KR6-13L-35K-120V-10V-RBH*-KR6TA & KR6T-SSGC-WF AE B BE C CE D CREE CREE CREE KR6-13L-35K-120V-10V-EB7-RBH*-KR6TA & KR6T-SSGC-WF 120V CR22-32L-35K-10V CR22-32L-35K-10V-EB14 120V 120V COOPER 4SNLED-LD4-32HL-LN-UNV-L835-CD-1-U-AYC-CH AIN/SET COOPER 4SNLED-LD4-32HL-LN-UNV-EL14W-L835-CD-1-U-A YC-CHAIN/SET SLOAN LED 701269-WWLPY-MB & MULTIPLE POWER SUPPLIES & ALL ACCESSOREIS 120V LED, 3500K INCLUDED LED, 3500K INCLUDED LED, 3500K INCLUDED LED, 3500K INCLUDED Fixture Finish Mounting RECESSED CLG WHITE RECESSED CLG WHITE LAY-IN CLG LAY-IN CLG SUSPENDED WHITE WHITE WHITE Remarks (Type) Description GENERAL LTG 6" LED DOWNLIGHT WITH 1100 DELIVERED LUMENS, 0-10V DIMMING, SOFT SATIN GLOW REFLECTOR AND WHITE FLANGE/TRIM; C CHANNEL MOUNTING ACCESSORY. GENERAL LTG 6" LED DOWNLIGHT WITH 1100 DELIVERED LUMENS, 0-10V DIMMING, SOFT SATIN GLOW REFLECTOR AND WHITE FLANGE/TRIM, C-CHANNEL MOUNTING & EMERGNECY BATTERY BALLAST. GENERAL LTG 2' X 2' RECESSED LED FIXTURE WITH 3200 DELIVERED LUMENS. GENERAL LTG 2' X 2' RECESSED LED FIXTURE WITH 3022 DELIVERED LUMENS AND 1400 LUMEN EMERGENCY BATTERY BALLAST JANITOR 4' LED STRIP LIGHT WITH 3200 LUMENS AND SEMI-FROST LENS. 120V LED, 3500K INCLUDED SUSPENDED WHITE IT/ELEC 120V LED, 4200K INCLUDED MECHANICAL FASTNER WHITE COVE X1 EELP EDGU-1RC-BA-RC-EM-SD 120V LED INCLUDED CEILING - - X2 EELP EDGU-2RW-BA-RC-EM-SD 120V LED INCLUDED CEILING - - 5. 6. 102A 314.361.0000 ph 314.361.9191 fax ELECTRICAL KEYED NOTES: 319.343.7055 ph hkwarchitects.com 1 PROVIDE WATTSTOPPER PEANUT LIGHTING CONTROL PANEL #LP8S-8-115 WITH EIGHT RELAY'S, ASTRONOMICAL TIME CLOCK AND LOW VOLTAGE INPUTS. EC SHALL PROGRAM ACCORDING TO PNC'S REQUEST, ALL LIGHTS SHALL COME ON 1 HOUR PRIOR TO NORMAL BUSINESS HOURS AND A ALL LIGHTS TO GO OFF 1 HOUR AFTER NORMAL BUSINESS HOURS (OR AS OTHERWISE INDICATED BY PNC.) 2 PROVIDE LOW VOLTAGE SWITCH EQUAL TO WATTSTOPPER AS-102-W COMPATIBLE WITH LIGHTING CONTROL PANEL. COORDINATE SWITCH FINISH WITH ARCHITECTURAL PLANS. SWITCH SHALL HAVE 2 BUTTONS, TOP BUTTON SHALL TURN ON ALL LIGHTS CONNECTED TO CONTROLLER, BOTTOM BUTTON SHALL TURN OFF ALL LIGHTS CONTROLLED BY CONTROLLER. 3 PROVIDE CONNECTION TO EXTERIOR SIGN; COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SIGN INSTALLER. CONNECT SIGN WITH DEDICATED CIRCUIT THRU LIGHTING CONTROLLER. PROGRAM WITH ASTRONOMICAL CLOCK TO BE ON AT DUSK AND OFF AT DAWN. 4 MOUNT POWER SUPPLY TRANSFORMER ABOVE ACCESSIBLE CEILING. 5 PROVIDE LOW VOLTAGE SWITCH EQUAL TO WATTSTOPPER AS-102-W COMPATIBLE WITH LIGHTING CONTROL PANEL. COORDINATE SWITCH FINISH WITH ARCHITECTURAL PLANS. SWITCH SHALL HAVE 2 BUTTONS, TOP BUTTON SHALL TURN ON ALL EXTERIOR SIGN LIGHTS CONNECTED TO CONTROLLER, BOTTOM BUTTON SHALL TURN OFF ALL EXTERIOR SIGN LIGHTS CONTROLLED BY CONTROLLER. PROVIDE PERMANENT LABEL READING 'EXTERIOR SIGN LIGHT OVERRIDE'. 6 OCCUPANCY SENSOR SHALL ALSO CONTROL EXHAUST FAN IN ROOM. 7 COORDINATE ROUGH-IN LOCATION WITH T-STAT AND MC. 8 PROVIDE ROUGH-IN FOR ALL SPEAKERS AND VOLUME CONTROLS. PROVIDE WPW #2524WT OR EQUAL #18G/2C TWISTED PLENUM CABLING FOR SPEAKERS. REVIEW EXACT ROUTING AND CONNECTIONS WITH SPEAKER INSTALLER PRIOR TO WORK. 18207 Edison Avenue Chesterfield, M0 63005 636.530.7770 ph 636.530.7877 fax Concierge 102 AE B B 13NL B 11j B 11j BE 11j B 7LCa 13NL B 7LCa B 7LCa V 13NL MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 IOWA 1000 Melrose Avenue Iowa City, IA 52246 CEILING MOUNTED SINGLE FACE LED EDGE LIT EXIT SIGN WITH WHITE HOUSING, RED PANEL, BATTERY PACK, AND ARROWS AS INDICATED ON DRAWING. CEILING MOUNTED DOUBLE FACE LED EDGE LIT EXIT SIGN WITH WHITE HOUSING, RED PANEL, BATTERY PACK, AND ARROWS AS INDICATED ON DRAWING. AE J 4. 4' LED STRIP LIGHT WITH 3200 LUMENS AND SEMI-FROST LENS AND 14W EMERGENCY BATTERY BALLAST. LED MODULES TO BE INSTALLED IN COVE; COORDINATE WITH ARCHITECTURAL PLANS AND DETAILS. PROVIDE ONE 60W POWER SUPPLY PER 25' RUN OR AS OTHERWISE REQUIRED BY MFR; PROVIDE ALL REQUIRED MOUNTING AND CONNECTION ACCESSOREIS; MOUNT POWER SUPPLY ABOVE ACCESSIBALE CEILING. ATM Vestibule 100 REFER TO SHEET E0.1 FOR SYMBOLS, ABBREVIATIONS AND GENERAL CONSTRUCTION NOTES. REFER TO THE ELECTRICAL DETAILS SHEET(S) FOR SEISMIC SUPPORTS OF LIGHTING FIXTURES. SUSPENDED CEILING SYSTEMS ARE DESIGNED TO SUPPORT THE WEIGHT OF ALL LIGHTING FIXTURES. THE STRUCTURAL FRAMING SHALL SUPPORT ALL CONDUITS, JUNCTION BOXES, ETC ABOVE CEILINGS. EMERGENCY LIGHTING THAT IS SHOWN TO BE SWITCHED, CONNECT EMERGENCY BALLAST VOLTAGE SENSING LEAD AHEAD OF SWITCH LEG OR OTHER CONTROL DEVICE. INFORMATION ON THIS SHEET IS COMPILED FROM EXISTING DRAWINGS AND CASUAL FIELD OBSERVATIONS AND SHALL BE CONSIDERED APPROXIMATE ONLY. VERIFICATION OF ALL EQUIPMENT AND FIXTURES, EITHER SHOWN OR NOT SHOWN ON THESE PLANS, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL FIELD VERIFY EXISTING EQUIPMENT AND FIXTURES PRIOR TO STARTING WORK. NOTIFY ENGINEER IMMEDIATELY IF DISCREPANCIES EXIST. 11j 13NL 11j 8 2 X1 B 7LCa J 4 B 7LCa BE 7LCa A B A 7LCb 7LCb 7LCb B B 13NL 7LCa BE B 7LCa B 13NL 7LCa Lobby 119 13 X1 102B BE 13NL B 7LCb B BE 7LCb 7LCb B 13NL B B 7LCb D D LCP 9 CE 102B OS 13NL OS X1 11 Office 117 S 11 Office (TYP.) 116 V B V B 11 8 S 13 11 S 11 ELECTRICAL LIGHTING PLAN - DEMOLITION NORTH 13 OS 9 6 BE 6 BE 9 Revision Schedule 9 11 Self-Serve Boxes Coupon Booth Toilet 112 108 114 ELECTRICAL LIGHTING PLAN - RENOVATION SCALE: 1/8" = 1'-0" 7LCa No Customer Pantry 113 SCALE: 1/8" = 1'-0" 13NL BE B 7LCa B B OS 8 (TYP.) S BE 7LCa 11 Office 115 B B 13NL B V 11 Office 118 B Elec/Data 105 V B 1 LV BE 11 BE OS D OS D OS B The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. C X2 OS NORTH 5 13 7LCb OS J 11 Break Room 109 TS 7LCb B Maintenance 104 Janitor 107 B 11 13 B 13NL 7LCb 13 B X1 7LCb D 7 S A BE 7LCb 11i 13NL LV 13NL 7LCb S A (TYP.) 17 LCc 7LCb Toilet 106 Bid Set AE 7LCb 912 Meramec Station Road, Valley Park, MO 63021 AE B Off-Stage 103 PNC Valley Park 13 BE A PNC Bank 3 B J J 13NL A SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION 13NL X1 A OS A i 11i OS AE j AE Date Description April 11, 2016 16.008.00 ELECTRICAL LIGHTING PLAN E1.1 Copyright 2016 HKW Architects ELECTRICAL KEYED NOTES: ELECTRICAL GENERAL NOTES: REFER TO SHEET E0.1 FOR SYMBOLS, ABBREVIATIONS AND GENERAL CONSTRUCTION NOTES. ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, AND HVAC WORK SHALL BE COORDINATED BY THE CONTRACTOR DOING THE WORK. ANY CORRECTIONS TO ANY OF THE ABOVE SHALL BE AT THE CONTRACTOR'S EXPENSE. ALL DISCONNECTS REQUIRED SHALL BE PROVIDED BY THE EC, U.N.O. SEE MECHANICAL & PLUMBING EQUIPMENT SCHEDULE(S) FOR EQUIPMENT DETAILS AND FOR DISCONNECTS FURNISHED BY OTHERS. REFER TO MANUFACTURER'S SPECIFICATIONS FOR MECHANICAL & PLUMBING EQUIPMENT CONNECTION DETAILS. COORDINATE WITH APPLICABLE TRADES. PROVIDE EQUIPMENT GROUNDING CONDUCTOR IN ALL FEEDERS, SIZED IN ACCORDANCE WITH NEC ARTICLE 250.122, SEE SPECIFICATIONS. REFER TO ELECTRICAL DETAILS SHEET(S) FOR ADDITIONAL PHONE AND DATA REQUIREMENTS. INFORMATION ON THIS SHEET IS COMPILED FROM EXISTING DRAWINGS AND CASUAL FIELD OBSERVATIONS AND SHALL BE CONSIDERED APPROXIMATE ONLY. VERIFICATION OF ALL EQUIPMENT AND DEVICES, EITHER SHOWN OR NOT SHOWN ON THESE PLANS, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. CONTRACTOR SHALL FIELD VERIFY EXISTING EQUIPMENT AND DEVICES PRIOR TO STARTING WORK. NOTIFY ENGINEER IMMEDIATELY IF DISCREPANCIES EXIST. THE FIRE ALARM IS A BUILDING WIDE SYSTEM MAINTAINED BY LANDLORD. EC SHALL PERFORM WORK AS INDICATED. BUT MUST COORDINATE ALL FA WORK WITH LANDLORD. PRIOR TO ANY SAWCUTTING OF THE FLOOR SLAB, CONTRACTOR SHALL XRAY THE FLOOR TO AVOID HITTING OTHER UTILITIES OR RE-BAR. COORDINATE EXACT ROUTE TO MINIMIZE DISTURBANCE TO FLOOR SLAB. REVIEW AND COORDINATE ALL SAWCUTTING WITH LANDLORD PRIOR TO WORK 9. 21 TV 23 28 15 A 13 102A 15 35 33 F 31 29 27 19 20 26 6 TV 26 3 41 12 24 24 6 Lobby 119 10 F +2 6 " V PROVIDE DEDICATED RECEPTACLE FOR DIEBOLD. COORDINATE EXACT REQUIREMENTS AND LOCATION WITH DIEBOLD. 10 PROVIDE FLOOR BOX EQUAL TO LEGRAND RFB-2-OG WITH COVER; PREPARED WITH DUPLEX RECEPTACLE AND DATA/VOICE OUTLET. SAW CUT FLOOR TO ACCESSIBLE WALL. PROVIDE (1) 1" CONDUIT FOR POWER AND (2) 1-1/4" CONDUIT FOR LOW VOLTAGE, ROUTED TO ACCESSIBLE WALL. PROVIDE BRONZE COVER FPBTCBZ. PATCH AND FILL AS REQUIRED. XRAY FLOOR PRIOR TO SAWCUTTING. 11 PROVIDE (2) CIRCUITS AT EACH NEW TELLER POSITION. FIELD INSTALL TWO RECEPTACLES AND TWO DATA J-BOXES AS SHOWN; COORDINATE EXACT LOCATIONS WITH TELLER STATION INSTALLER PRIOR TO WORK. 12 SAW CUT FLOOR AND PROVIDE (1) 1" POWER FEED AND (2) 1-1/4" LOW VOLTAGE FEEDS PER TELLER STATION STUBBED THROUGH WALL CAVITY, BELOW SLAB, AND STUBBED UP AT TELLER CONCIERGE DESK. COORDINATE EXACT LOCATION WITH OWNER'S MILLWORK PROVIDER PRIOR TO SAWCUTTING. 13 PROVIDE ROUGH-IN FOR SECURITY KEYPAD. KEYPAD TO BE PROVIDED BY OWNER'S SECURITY CONTRACTOR. 14 DEDICATED RECEPTACLE FOR MFD PRINTER; COORDINATE ELEVATION WITH ARCHITECTURAL PLANS. 15 DEDICATED RECEPTACLE FOR MICR PRINTER; COORDINATE ELEVATION WITH ARCHITECTURAL PLANS. 16 EXISTING ELECTRICAL PANEL TO REMAIN. PANEL IS NOT CONNECTED TO AN ELECTRICAL SERVICE; PANEL IS FOR LANDLORDS FUTURE USE ONLY. 17 PROVIDE CONNECTION TO UNIT HEATER; COORDINATE WITH MC. 18 PROVIDE 10" X 2" X 1/4" COPPER GROUND BUS FOR GROUNDING OF IT EQUIPMENT. PROVIDE A #6AWG BARE COPPER CONDUCTOR FROM GROUND BUS TO INCOMING ELECTRICAL EXISTING GROUNDING SYSTEM. 19 RELOCATE FIRE ALARM NOTIFICATION APPLIANCE. COORDINATE ALL WORK WITH LANDLORDS FIRE ALARM VENDOR. EXTEND WIRING AS REQUIRED. REMOVE, PROTECT AND RE-INSTALL AS SHOWN. 20 REMOVE DEVICE AND WIRING, MAINTAIN ROUGH-IN. RE-CIRCUIT AS INDICATED ON RENOVATION PLAN. 21 DISCONNECT EXISTING WATER HEATER ABOVE CEILING; MAINTAIN CONDUIT; PROVIDE NEW # 10 AWG CONDUCTOR TO PANEL AND NEW BREAKER PER MFR. SPECS., AND CONNECT NEW WATER HEATER. 22 CONTROL EF WITH LIGHTING OCCUPANCY SENSOR. SEE LIGHTING PLAN. 23 PROVIDE CONNECTION TO LINE VOLTAGE THERMOSTAT. COORDINATE EXACT REQUIREMENTS WITH TCC & MC. 24 PROVIDE NEW DEVICE IN EXISTING ROUGH-IN; PROVIDE NEW WIRING AND WALL PLATE; COORDINATE FINISH WITH ARCHITECTURAL PLANS. 25 COORDINATE ALL ROUGH-IN WORK ALONG PERIMETER WALLS WITH PNC SECURITY AND WIRE MESH INSTALLER TO MAINTAIN SECURITY OF WIRE MESH BEING INSTALLED. 26 PROVIDE 4' X 4' FIRE RETARDANT PLYWOOD BACKER BOARD FOR SECURITY CONTRACTOR. LOCATE 5 DUPLEX RECEPTACLES AT BACKER BOARD, COORDINATE EXACT LOCATION OF RECEPTACLES WITH DIEBOLD PRIOR TO WORK. 27 PROVIDE DUPLEX AND LOW VOLTAGE ROUGH-IN FOR TV ABOVE ATM. ROUGH-IN SHALL BE FROM BEHIND IN CASH ROOM; COORDINATE EXACT ROUGH-IN WITH ARCHITECTURAL DETAILS. IT VENDOR TO PROVIDE DATA CABLES FOR TV AS REQUIRED. 28 PROVIDE DUPLEX AND LOW VOLTAGE ROUGH-IN FOR TV ABOVE TELLER COUNTER; COORDINATE EXACT LOCATION AND ELEVATIONWITH ARCHITECTURAL DETAILS. IT VENDOR TO PROVIDE DATA CABLES FOR TV AS REQUIRED. 29 PROVIDE ALTERNATE PRICING AS OUTLINED ON E0.1. 30 PROVIDE AND COORDINATE ROUGH-IN IN EXTERIOR WALL FOR EXTERIOR CAMERA. 24 21 +3 4 " 41 GFI GFI 22 20 Break Room 23 109 2 DC EF 8 25 3 12 Janitor+46" 107 20 T 102B LCP 12 32 14 9 8 18 TGB 5 Elec/Data 105 102B 29 F V 20 +46" 34 20 ABV CLG 16 16 16 J GFI GFI 18 Office 115 A 18 Office 116 A 18 Office 117 A A Office 118 16 GFI GFI Self-Serve Boxes 114 Passage 111 +24" GFI 10 Coupon Booth 112 Toilet 108 25 ELECTRICAL POWER & SYSTEMS PLAN - DEMOLITION ELECTRICAL POWER & SYSTEMS PLAN - RENOVATION SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" NORTH The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. NORTH 9 J 8 GFI 8 REQUIRED ELECTRICAL CLEARANCE EF 9 1 18 21 EF 2 Toilet 40 106 8 GFI 22 21 25 Revision Schedule No Date Description 19 15 8 Customer 8 Pantry 113 636.530.7770 ph 636.530.7877 fax Maintenance 104 26 13 12 15 9 18207 Edison Avenue Chesterfield, M0 63005 21 21 +46" 19 PROVIDE TWO DEDICATED RECEPTACLES FOR IT RACK; ONE QUAD AND ONE DUPLEX. COORDINATE LOCATION AND TYPE WITH PNC. 2 26 F TV 41 20 8 Off-Stage 103 DC 15 DD K 1 EXISTING FIRE ALARM DEVICE TO REMAIN. PROTECT DURING CONSTRUCTION. FD J 23 7 24 15 +67" 23 Concierge 102 11 4 30 23 GFI F +24" 15 14 T DD 37 +67" TV 36,38 FD C 15 F 7 +24" 19 27 J V 1 25 39 +67" K EH 20 23 EXISTING DUCT DETECTOR TO BE PROTECTED AND REMAIN. RE-ROUTE WIRING AS REQUIRED TO ACCOMMODATE NEW WORK. +24" +67" J Cash Room 101 J 16 20 15 26 319.343.7055 ph hkwarchitects.com 6 15 V +24" J ATM Vestibule 100 17 28 IOWA 1000 Melrose Avenue Iowa City, IA 52246 IT RACK AND CABLE TRAY BY PNC. COORDINATE WITH PNC DURING CONSTRUCTION TO RESERVE ADEQUATE SPACE. PROVIDE #6 COPPER GROUND CONDUCTOR FROM CABLE TRAY AND EACH IT RACK TO GROUND BAR. 5 FOR ATM; COORDINATE EXACT LOCATIONS WITH ATM INSTALLER. 24 314.361.0000 ph 314.361.9191 fax PROVIDE 3/4" CONDUIT TO ALARM PANEL. PROVIDE ADDITIONAL SEALTITE CONDUIT FROM JUNCTION BOX TO SAFE. 4 EC SHALL PROVIDE ROUGH-IN'S FOR ALL DATA, VOICE, SOUND, SECURITY, ACCESS CONTROL AND OTHER LOW VOLTAGE SYSTEMS. LOW VOLTAGE EQUIPMENT HAS BEEN SHOWN FOR REFERENCE ONLY; COORDINATE EXACT REQUIREMENTS WITH RESPECTIVE TRADES. REFER TO SECURITAS SECURITY DRAWING 'SEC-1' DATED 03/31/16 FOR MORE DETAILS REGARDING SECURITY ROUGH-IN REQUIREMENTS. EC SHALL PROVIDE ALL ROUGH-INS; ALL CABLING (OTHER THAN SPEAKER WIRING) WILL BE FURNISHED BY OTHERS. COORDINATE PRIOR TO CEILING AND DRYWALL BEING INSTALLED. 30 MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 Bid Set 8. 3 PROVIDE DUPLEX AND LOW VOLTAGE ROUGH-IN FOR TWO TV'S; TV'S ARE STACKED VERTICALLY AND OFFSET HORIZONTALLY; REFER TO ARCHITECTURAL DETAILS FOR MORE INFORMATION. IT VENDOR TO PROVIDE DATA CABLES FOR TV AS REQUIRED. 912 Meramec Station Road, Valley Park, MO 63021 7. PROVIDE LOW VOLTAGE TRANSFORMER FOR DOOR BELL CHIME SYSTEM AND MOUNT ABOVE ACCESSIBLE CEILING. PNC Valley Park 5. 6. 2 PNC Bank 4. CONNECT DOOR CHIME TO BUTTON AT REMOTE ENTRY. PROVIDE NUTONE HARDWIRED DOOR CHIME KIT MODEL BK125WH OR APPROVED EQUAL, (2) DOOR CHIMES, (2) TRANSFORMERS AND LOW VOLTAGE WIRING PER MANUFACTURER'S RECOMMENDATION TO OPERATE BOTH CHIMES FROM A SINGLE BUTTON. 9 22 SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION 3. 1 +46" 1. 2. April 11, 2016 16.008.00 ELECTRICAL POWER & SYSTEMS PLAN E2.1 Copyright 2016 HKW Architects FIRE PROTECTION BRANCH LINE FIRE PROTECTION SYMBOLS LEGEND ANCHORAGE & SWAY BRACING - MECHANICAL SYSTEM COMPONENTS CONNECTION OF NEW TO EXISTING Occupancy Category ( II ) RETURN BEND CONNECTED TO TOP OF BRANCH LINE PIPING, TYP. RETURN BEND Seismic Design Category ( D ) ANCHORAGE TO FLOORS, ROOFS, ETC. LISTING OF EQUIPMENT AND SYSTEM COMPONENTS Not Provided PIPING SWAY BRACING Provided - LOCATION OF PROFESSIONALLY SEALED ANCHORAGE AND SWAY BRACING DETAILS Not Provided Provided X - Drawing No. or Spec. Section X Shop Drawings - BY FPC COMMENTS Separate Permit & Plans BRACE PIPING AS REQUIRED IN NFPA 13 & 14 - VIBRATION ISOLATION AND SEISMIC RESTRAINT SCHEDULE PENDENT SPRINKLER HEAD AFF ABOVE FINISHED FLOOR BOP BOTTOM OF PIPE BRZ BRONZE EC ELECTRICAL CONTRACTOR ECV EXTENDED COVERAGE FPC FIRE PROTECTION CONTRACTOR GRVD GROOVED HSW HORIZONTAL SIDEWALL PC PND PENDENT AMPLIFICATION FACTOR QR QUICK RESPONSE STND STANDARD 1.0 THR THREADED UPR UPRIGHT SPR SPRINKLER PIPING EQUIPMENT TAG ISOLATION SPEC. SEISMIC RESTRAINT ISOLATOR DEFLECTION IMPORTANCE FACTOR SPR-PIPING SC YES - 1.5 2.5 1. SEE THIS SHEET FOR SYMBOLS AND ABBREVIATIONS. 2. THESE GENERAL DEMOLITION NOTES APPLY TO ALL DEMOLITION WORK. 3. DEMOLISH PIPING AND EQUIPMENT SHOWN CROSS HATCHED. 4. THESE DRAWINGS MAY NOT FULLY DEPICT ALL AS-BUILT CONDITIONS, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS. NOTIFY THE ENGINEER AT ONCE SHOULD A DISCREPANCY OR OMISSION BE FOUND. 5. CONTRACTOR SHALL USE CAUTION WHEN REMOVING PIPING AND EQUIPMENT TO AVOID DAMAGE TO ELECTRICAL WIRING THAT IS TO REMAIN. NOTIFY GC AND EC IF WIRING IS FOUND ATTACHED TO PIPING. 6. PLUMBING CONTRACTOR COMPONENT RESPONSE MODIFICATION FACTOR FIRE PROTECTION GENERAL DEMOLITION NOTES: 7. EXISTING SPRINKLER HEAD 9. SPRINKLER DEMOLITION WORK: VERIFY EXISTING SERVICES TO REMAIN. ALL NECESSARY CARE SHALL BE TAKEN DURING DEMOLITION TO PREVENT DAMAGE TO FIRE PROTECTION, PLUMBING, ELECTRICAL, AND MECHANICAL SYSTEMS TO REMAIN. FIRE PROTECTION SYSTEMS SERVING OTHER AREAS SHALL PROVIDE FOR UNINTERRUPTED SERVICE TO THOSE AREAS UNLESS PRIOR WRITTEN APPROVAL IS RECEIVED FROM THE OWNER. COORDINATE ALL SUCH WORK WITH THE GENERAL CONTRACTOR AND OWNER'S ON SITE REPRESENTATIVE. FIRE PROTECTION GENERAL RENOVATION NOTES: NOT TO SCALE 1. THESE DRAWINGS ARE ACCOMPANIED BY SPECIFICATIONS. 2. THIS CONTRACTOR SHALL COORDINATE WITH OTHER CONTRACTORS IN THE LOCATION OF ALL PIPING AND EQUIPMENT TO PREVENT INTERFERENCE. 3. PROVIDE ALL NECESSARY OFFSETS IN PIPING TO AVOID STRUCTURE. 4. IN SPACES WITHOUT CEILINGS PROVIDE ROUGH BRONZE UPRIGHT SPRINKLER HEADS. IN SPACES WITH CEILINGS, REFER TO SPECIFICATIONS FOR SPRINKLER HEAD TYPES. IN DRYWALL CEILINGS, SPRINKLER HEADS SHALL ALIGN WITH LIGHT FIXTURES AND OTHER CEILING MOUNTED DEVICES. CONTRACTOR SHALL COORDINATE SPRINKLER HEAD LOCATIONS WITH ARCHITECT'S REFLECTED CEILING PLAN, AND PROVIDE ADDITIONAL SPRINKLER HEADS WHERE REQUESTED BY ARCHITECT. 4'-0" 1'-0" 1'-0" LARGE WASHER 1'-0" BOTTOM CHORD OF JOIST LOCK NUT RETAINING CLIP 1'-0" 1'-0" 1 2'-0" "C" CLAMP 1'-0" LARGE WASHER 4 BOTTOM CHORD OF JOIST LOCK NUT LOCK NUT 5 PROVIDE A SUPPORT ANGLE SPANNING TWO OR MORE JOISTS; 3x3x1/4" SUPPORT ANGLE WHERE JOIST SPACING IS OVER 2'-0" BUT NOT MORE THAN 4'-0". PROVIDE 2x2x1/4" SUPPORT ANGLE WHERE JOIST SPACING IS 2'-0" AND UNDER. WHERE LOAD EXCEEDS 500 POUNDS PER HANGER, SEE STRUCTURAL DRAWINGS FOR DETAILING. 2 FIELD WELD STIFFENER TO BAR JOIST TOP AND BOTTOM CHORD. 3 PROVIDE STIFFENER ANGLE WHERE LOAD BEING HUNG EXCEEDS 250 LBS. 4 THIS METHOD ALLOWABLE FOR MAX. 150 LB. LOAD WITHIN 6" OF PANEL POINT; BEYOND 6" OF PANEL POINT 50 LB. MAX. LOAD ALLOWABLE. 5. PRIOR TO COMMENCING WORK, APPROVAL SHALL BE RECEIVED FROM THE OWNERS INSURANCE COMPANY, ENGINEER, FIRE MARSHAL AND OWNER. 5 THIS METHOD ALLOWABLE FOR MAX. 50 LB. LOAD WITHIN 6" OF PANEL POINT; BEYOND 6" OF PANEL POINT THIS METHOD IS NOT ALLOWED. 6. UPON COMPLETION, THIS CONTRACTOR SHALL PROVIDE A COMPLETE AND FUNCTIONING SYSTEM. 7. PROVIDE SEISMIC BRACING AS REQUIRED FOR NEW PIPING. 8. FIRE PROTECTION CONTRACTOR SHALL PERFORM A FLOW TEST. FLOW TEST RESULTS INCLUDING DATE OF TEST, LOCATION OF TEST HYDRANT, LOCATION OF FLOW HYDRANT, STATIC PRESSURE, RESIDUAL PRESSURE AND TEST FLOW GPM SHALL BE SUBMITTED WITH HYDRAULIC CALCULATIONS. 9. THE FIRE PROTECTION CONTRACTOR SHALL SUBMIT HYDRAULIC CALCULATIONS AND SHOP DRAWINGS SIGNED AND SEALED BY A FIRE PROTECTION ENGINEER REGISTERED IN THE STATE WHERE THE PROJECT IS LOCATED. HANGER ROD SPRINKLER HEAD HANGER ROD 2'-0" 1/2"Ø BOLT 1 SUPPORT ANGLE 1'-0" A 1'-0" THIS DETAIL 1-1/2x1-1/2x3/16" STIFFENER 3 LARGE WASHER BOTTOM CHORD OF JOIST PANEL POINT 1'-0" LOCK NUT LOCK NUT LOCK NUT 319.343.7055 ph hkwarchitects.com 18207 Edison Avenue Chesterfield, M0 63005 636.530.7770 ph 636.530.7877 fax 10. THE OWNER WILL BE RESPONSIBLE FOR THE REMOVAL OF ANY ACMs (ASBESTOS CONTAINING MATERIALS, PCBs OR OTHER HAZARDOUS MATERIALS) PRESENTLY EXISTING WITHIN THE AREAS AFFECTED BY THE PROJECT SCOPE, THAT WOULD BE REQUIRED TO BE REMOVED FOR THE WORK. ABATEMENT WORK, IF REQUIRED, IS NOT PART OF THIS CONTRACT. RETURN BEND PIPING TO WET AND DRY PENDENTS LOCK NUT IOWA 1000 Melrose Avenue Iowa City, IA 52246 WHERE ITEMS ARE REMOVED, UTILITIES AND THE AREA FROM WHICH THE ITEMS HAVE BEEN REMOVED SHALL BE LEFT IN SUCH A MANNER THAT IS SAFE FOR BOTH PEOPLE AND PROPERTY ON A DAILY BASIS. SEE ARCHITECTURAL DRAWINGS FOR ARCHITECTURAL DEMOLITION. REFER TO MEP AND SPRINKLER DEMOLITION PLANS FOR MEP DEMOLITION. UPRIGHT SPRINKLER HEAD DRY PENDENT SPRINKLER HEAD NOTE: DRY BARREL SHALL BE PROVIDED FOR THE ENTIRE LENGTH OF THE DROP PIPING FROM THE SPRINKLER HEAD TO THE ELBOW AT THE TOP OF THE RETURN BEND. DRY PENDENTS SHALL NOT INCLUDE A DRAIN OUTLET IN DROP PIPING. 314.361.0000 ph 314.361.9191 fax WHEREVER EXISTING EQUIPMENT, PIPING AND EQUIPMENT, ETC., ARE TO BE REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGERS, FOUNDATIONS, ETC., UNLESS NOTED OTHERWISE. AFTER REMOVAL; FLOORS, WALLS AND CEILINGS SHALL BE PATCHED AND FINISHED TO MATCH ADJOINING SURFACES. 8. PENDENT SPRINKLER HEAD MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 2'-0" 10. CONTRACTOR SHALL PROVIDE ALL DOCUMENTATION AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION TO DEMONSTRATE COMPLIANCE WITH NFPA 13. 1'-0" HANGER ROD 11. PIPING SHALL BE INSTALLED AS HIGH AS POSSIBLE. 2 HANGER ROD BOTTOM CHORD OF JOIST LARGE WASHER LOCK NUT SPRINKLER HEAD 6" NOTE: ALL PENETRATIONS OF SPRINKLER HEADS IN AN ACCOUSTICAL CEILING PANEL SHALL BE CENTERED. 1/2"Ø BOLT 6" B A THIS DETAIL THIS DETAIL CEILING PANEL PENETRATION DETAIL TYPICAL JOIST HANGER DETAIL FOR PIPING AND EQUIPMENT NOT TO SCALE NOT TO SCALE 1 SUPPORT ANGLE SECTION B 13. WHERE PIPING ELEVATION CONFLICTS WITH DUCTWORK, OFFSETS TO FIRE PROTECTION PIPING SHALL BE UP AND OVER DUCTWORK. WHERE CONFLICTS OCCUR, PIPING SHALL NOT BE ROUTED DOWN BELOW DUCTWORK WHERE THIS PIPING WOULD BE WITHIN 12" OF CEILING ELEVATION. 14. PROVIDE AUXILIARY DRAINS AS REQUIRED FOR DRAINING TRAPPED SECTIONS OF PIPING. FOR TRAPPED SECTIONS OF PIPING EXCEEDING 5 GALLONS IN CAPACITY, PROVIDE A HARD-PIPED DRAIN CONNECTION AND ROUTE BACK TO DRAIN IN SPRINKLER RISER ROOM. SECTION THIS DETAIL N.T.S. 12. PIPING SHALL BE ROUTED A MINIMUM OF 12" ABOVE CEILING. N.T.S. 15. PIPE ROUTING SHOWN ON DRAWINGS IS FOR REFERENCE ONLY. FIRE PROTECTION CONTRACTOR SHALL COORDINATE WITH STRUCTURAL DRAWINGS, ELECTRICAL AND MECHANICAL DRAWINGS FOR LOCATIONS AND ELEVATIONS OF PIPING. NO CHANGE TO THE CONTRACT PRICE WILL BE ACCEPTED WHERE ALTERNATE PIPING ROUTES ARE REQUIRED. 16. CONTRACTOR SHALL PROVIDE A FIRE WATCH DURING CONSTRUCTION HOURS. COORDINATE WITH LOCAL FIRE DEPARTMENT FIRE WATCH REQUIREMENTS. OBTAIN A FIRE WATCH INSPECTION FORM AND LOG INSPECTION TIME PER FIRE DEPARTMENT'S REQUIREMENTS. THREADED HANGER ROD TOP CHORD OF JOIST, TYP. 2 MEMBERS BRACE PIPE TOLCO FIGURE 907 SWAY BRACE ATTACHMENT NO-THREAD SWIVEL SWAY BRACE ATTACHMENT PIPE CLAMP FOR SWAY BRACE CONCENTRICALLY LOADED BAR JOIST - TOP CHORD 3" MAX THREADED HANGER ROD NUT WASHER 4 WAY EARTHQUAKE BRACE NO SCALE LONGITUDINAL EARTHQUAKE BRACE NO SCALE Revision Schedule MIN. 45°-90° TYPICAL CONCENTRICALLY LOADED BAR JOIST - BOTTOM CHORD MIN. 45°-90° TYPICAL SWAY BRACE ATTACHMENT CONCENTRICALLY LOADED JOIST ATTACHMENT DETAIL NOT TO SCALE BRACE PIPE SWIVEL SWAY BRACE FITTING SWIVEL SWAY BRACE FITTING (2) SWAY BRACE ATTACHMENT (2) TYPICAL BAR JOIST AND BEAM HANGER ATTACHMENT NOTES: 1. ADDITIONAL HANGERS SHALL BE REQUIRED TO LIMIT THE LOAD ON EACH STRUCTURAL MEMBER BELOW THE MAXIMUM LOAD ALLOWED. COORDINATE WITH STRUCTURAL ENGINEER OF RECORD TO PREVENT OVERLOADING. The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. 2. WHEN MULTIPLE PIPES/DUCTWORK ARE PERPENDICULAR TO JOISTS, HANGERS SHALL BE STAGGERED SO THAT PIPING/DUCTWORK IS NOT SUPPORTED FROM A SINGLE JOIST. LATERAL EARTHQUAKE BRACE NO SCALE FAST CLAMP RISER BRACE NO SCALE GENERAL: PIPING: 1. NO BRACING IS REQUIRED IF THE TOP OF PIPING IS SUSPENDED 12" OR LESS FROM THE SUPPORTING STRUCTURAL MEMBER. 1. BRACE ALL PIPES 2-1/2"Ø AND LARGER. IN MECHANICAL ROOMS, BRACE ALL PIPING 1-1/4"Ø AND LARGER. 3. HANGERS AND SUPPORT COMPONENTS SHALL BE FACTORY FABRICATED OF MATERIALS, DESIGN, AND MANUFACTURER COMPLYING WITH MSS SP-58 AND MSS SP-69 AND SPECIFICATION 15010. 210010, 220010 OR 230010. COMPLY WITH LOAD RATINGS FOR EACH TYPE. 2. WALLS, INCLUDING DRYWALL PARTITIONS, MAY REPLACE REQUIRED TRANSVERSE OR VERTICAL BRACING FOR PIPING. 2. TRANSVERSE AND VERTICAL BRACING SHALL OCCUR AT 40' INTERVALS, MAXIMUM. LONGITUDINAL BRACING SHALL OCCUR AT 80' INTERVALS, MAXIMUM. 4. BEAM CLAMPS SHALL COMPLY WITH MSS TYPE 19-23, 25, 27-34. TYPE 19 AND 23 C-CLAMPS SHALL HAVE LOCKNUTS AND RETAINING DEVICES, FURNISHED BY THE MANUFACTURER. 3. ATTACHMENT TO STRUCTURAL MEMBERS SHALL USE DEVICES INCLUDED IN FEDERAL SPECIFICATION WW--H-171 (MSS SP-58) OR BE BOLTED/WELDED AS APPROVED BY THE ENGINEER. BRACES SHALL BE CONNECTED TO THE HANGERS/SUPPORTS FOR PIPING AND SUSPENDED EQUIPMENT. 3. AT PIPE RISERS, WHEREVER POSSIBLE, SUPPORT THE WEIGHT OF THE RISER AT A POINT OR POINTS ABOVE THE CENTER OF GRAVITY OF THE RISER. 5. FOR BUILDINGS WITH JOISTS MADE BEFORE 1985, ALL CLAMPS SHALL BE ATTACHED TO THE UPPER CHORD OF JOISTS. 6. PROVIDE BEAM CLAMPS WITH RETAINING CLIPS FOR INSTALLATIONS WHERE SEISMIC BRACING IS REQUIRED. 7. HANGERS THAT ARE PART OF A SEISMIC RESTRAINT SHALL BE INSTALLED IN CONTACT WITH THE PIPE. 8. SUPPORT ANGLES AND STIFFENERS TO BE SUPPLIED AND INSTALLED BY CONTRACTOR. 4. SEE THE SPECIFICATIONS FOR REQUIRED STRENGTH OF BRACING. 5. LATERAL SEISMIC FORCE SHALL BE CONSIDERED TO ACT CONCURRENTLY WITH THE DEAD LOAD. THE SLENDERNESS RATIO (l/r) OF BRACES SHALL NOT EXCEED 200, WHERE (l) IS THE LENGTH OF THE BRACE AND (r) IS THE LEAST RADIUS OF GYRATION, BOTH IN INCHES. 6. SWAY BRACING METHODS SHOWN IN NFPA 13 (SPRINKLER PIPING) MAY BE USED IN LIEU OF DETAILS SHOWN ON THE DRAWINGS FOR PIPING. 7. BRACE ALL FIRE SUPPRESSION PIPING. 4. DO NOT FASTEN ON RIGID PIPING SYSTEM TO TWO DISSIMILAR PARTS OF THE BUILDING THAT MAY RESPOND IN A DIFFERENT MODE DURING AN EARTHQUAKE; FOR EXAMPLE, A WALL AND A ROOF. 5. DO NOT USE BRANCH LINES TO BRACE MAIN LINES. EQUIPMENT: 1. PROVIDE VIBRATION ISOLATORS & SWAY BRACING FOR ALL SUSPENDED EQUIPMENT. 2. PROVIDE NEOPRENE WASHER AND PAD FOR ALL PUMPS ANCHORED TO CONCRETE PADS. KEYED NOTES: 1 TYPICAL BAR JOIST & BEAM HANGER NOTES SEISMIC BRACING DETAILS AND NOTES NOT TO SCALE NOT TO SCALE ATTACH TO CONCRETE DECK OR STRUCTURAL MEMBERS VIA APPROVED ATTACHMENT METHOD, ATTACHMENT TO METAL ROOF DECK IS PROHIBITED. FIRE PROTECTION SHEET LIST Sheet Number Sheet Name FP0.1 FIRE PROTECTION NOTES & DETAILS FP1.1 FIRE PROTECTION PLAN SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION No BOTTOM CHORD OF JOIST, TYP. 2 MEMBERS Bid Set SWIVEL SWAY BRACE FITTING FIRE PROTECTION SYSTEM DELEGATED-DESIGN NOTE: THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGNING AND PROVIDING AN AUTOMATIC SPRINKLER SYSTEM BASED ON NFPA 13 REQUIREMENTS, THE AVAILABLE WATER FLOW AND PRESSURE AT THE SITE, AND IBC REQUIREMENTS FOR A FULLY SPRINKLERED BUILDING. ALL OCCUPIED AREAS SHALL BE SERVED BY WET-PIPE AUTOMATIC FIRE PROTECTION SYSTEMS. CONTRACTOR SHALL DESIGN ALL PIPE ROUTING, COORDINATE WITH STRUCTURAL ELEMENTS AND DETERMINE SPRINKLER HEAD LOCATIONS AND QUANTITIES REQUIRED. SPRINKLER HEAD LOCATIONS AND PIPING ROUTING ARE SHOWN FOR REFERENCE ONLY, AS AN AID TO BIDDING AND ARCHITECTURAL COORDINATION. THE FIRE PROTECTION CONTRACTOR SHALL BE RESPONSIBLE FOR PERFORMING A FLOW TEST, PROVIDING ENGINEERED SHOP DRAWINGS AND HYDRAULIC CALCULATIONS SIGNED AND SEALED BY A REGISTERED PROFESSIONAL ENGINEER IN THE STATE WHERE THE PROJECT IS LOCATED, AND DESIGNING, SIZING AND INSTALLING ALL PIPING, VALVES, SPRINKLERS, ETC. REQUIRED FOR A COMPLETE, FUNCTIONAL AND CODE COMPLIANT SYSTEM. 912 Meramec Station Road, Valley Park, MO 63021 MIN. 45°-90° TYPICAL 1 PNC Bank MIN. 45°-90° TYPICAL WASHER PNC Valley Park NUT Date Description April 11, 2016 16.008.00 FIRE PROTECTION NOTES & DETAILS FP0.1 Copyright 2016 HKW Architects FIRE PROTECTION GENERAL NOTES: 1. REFER TO SHEET FP0.1 FOR SYMBOLS, ABBREVIATIONS AND GENERAL CONSTRUCTION NOTES. 2. ADJACENT TENANT SPACE NOT IN SCOPE. 3. ITEMS SHOWN CROSS HATCHED TO BE REMOVED. MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 FIRE PROTECTION KEYED NOTES: 314.361.0000 ph 314.361.9191 fax 1 REMOVE SPRINKLER HEADS AND BRANCH PIPING BACK TO MAIN. 2 REMOVE EXISTING SPRINKLER HEAD WITHIN SPACE AND PLUG OUTLET. BRANCH PIPING TO REMAIN TO SERVE ADJACENT TENANT SPACE. IOWA 1000 Melrose Avenue Iowa City, IA 52246 3 EXISTING 2 1/2" CROSS-MAIN AT APPROXIMATELY 14'-2" AFF TO REMAIN. 4 PROVIDE THE DESIGN AND INSTALLATION OF A COMPLETE AND FUNCTIONAL AUTOMATIC FIRE PROTECTION SYSTEM IN THE AREA INDICATED. FIRE PROTECTION SYSTEM(S) SHALL BE DESIGNED PER NFPA 13 AND IBC REQUIREMENTS FOR A FULLY SPRINKLER BUILDING. PROVIDE ALL SPRINKLER HEADS, PIPING, HANGERS, ETC. AND COORDINATE LOCATIONS, PIPE ROUTING, SCHEDULING, AND ALL OTHER INSTALLATION REQUIREMENTS WITH OTHER TRADES. EXTEND NEW BRANCH LINES FROM EXISTING CROSS-MAIN OUTLETS. WHERE CROSS MAIN OUTLETS ARE NOT OF SUFFFICIENT QUANTITY PROVIDE A MECHANICAL TEE, TAP EXISTING SUPPLY MAIN AND PROVIDE ADDITIONAL BRANCH LINE(S). 5 319.343.7055 ph hkwarchitects.com 18207 Edison Avenue Chesterfield, M0 63005 636.530.7770 ph 636.530.7877 fax TO EXISTING VERTICAL BACKFLOW PREVENTER AND SYSTEM RISER. 4 ATM Vestibule Off-Stage Concierge EXISTING FP SERVICE MAIN 5 EXISTING 2-1/2" RISER MAIN @ 14'-2" AFF Maintenance SPR Janitor SPR SPR Customer Pantry 3 Office 2 2 2 Office Office Office Self-Serve Boxes 2 Passage Coupon Booth Toilet Toilet 2 Bid Set Elec/Data 1 PNC Valley Park 1 PNC Bank 1 1 912 Meramec Station Road, Valley Park, MO 63021 Break Room Lobby Revision Schedule The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. NORTH FIRE PROTECTION FLOOR PLAN - DEMOLITION FIRE PROTECTION FLOOR PLAN - RENOVATION SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" NORTH SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION No Date Description April 11, 2016 16.008.00 FIRE PROTECTION PLAN FP1.1 Copyright 2016 HKW Architects CEILING MOUNTED, SQUARE SUPPLY AIR DIFFUSER 4-WAY UNLESS OTHERWISE INDICATED (ARROW INDICATES DIRECTION OF THROW) X - EXISTING DRAIN RG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION CEILING MOUNTED RETURN AIR GRILLE SIDEWALL RETURN GRILLE HWS HOT WATER HEATING SUPPLY SIDEWALL SUPPLY DIFFUSER HWR HOT WATER HEATING RETURN SUPPLY AIR SLOT DIFFUSER X PIPE ANCHOR RECTANGULAR TAP WITH DAMPER (BOTTOM) CA COMPRESSED AIR G NATURAL GAS ROUND DUCT SUPPLY UP, DN OR IN SECTION LPG LIQUID PROPANE GAS ROUND DUCT RETURN UP, DN OR IN SECTION CWS CHILLED WATER SUPPLY PIPE DOWN CWR CHILLED WATER RETURN PIPE UP CHS CHILLED WATER SUPPLY TOP CONNECTION CHR CHILLED WATER RETURN BOTTOM CONNECTION CS CONDENSER WATER SUPPLY FLOW DIRECTION CR CONDENSER WATER RETURN LPS LOW PRESSURE STEAM MPS MEDIUM PRESSURE STEAM HPS HIGH PRESSURE STEAM LPC LOW PRESSURE CONDENSATE MPC MEDIUM PRESSURE CONDENSATE HPC PD MANUAL AIR VENT A AUTOMATIC AIR VENT THERMOWELL PRESSURE GAUGE HIGH PRESSURE CONDENSATE STEAM CONDENSATE PUMPED DISCHARGE LWS LOOP WATER SUPPLY LWR LOOP WATER RETURN P PNEUMATIC TUBING E ELECTRICAL WIRING MANIFOLD GAUGE THERMOMETER CAPPED OUTLET (UP) DEMO PIPE OR EQUIPMENT POINT OF CONNECTION NEW TO EXISTING DIRT LEG (DN) OPPOSED BLADE DAMPER H HUMIDISTAT T THERMOSTAT DD SD UNION PIPE GUIDE SMOKE DETECTOR (DUCT) FS T FLOW SWITCH DPS STEAM TRAP EXPANSION JOINT EJ DIFFERENTIAL PRESSURE SWITCH REDUCER PRESSURE SWITCH BASKET STRAINER X' - X" BOTTOM OF DUCT ELEVATION SUCTION DIFFUSER 24 X 12 OR 24 X 12 RECTANGULAR DUCT (FIRST NUMBER IS SURFACE STRAINER SHOWN-DIMENSIONS REPRESENT NET FREE AREA) GATE VALVE PS 12"Ø OR 12"Ø BALL VALVE ROUND DUCT TRIPLE DUTY VALVE BUTTERFLY VALVE RECTANGULAR TO ROUND TRANSITION PRESSURE REDUCING VALVE 18x12 12x12 18x12 CHECK VALVE TRANSITION GAS COCK 12x12 R DUCT WITH LINER BALANCING VALVE (FLOW CONTROL VALVE) INCLINED RISE (R) OR DROP (D) ARROW IN DIRECTION OF CHANGE RPBP - REDUCED PRESSURE BACKFLOW PREVENTER FLEXIBLE DUCT CONNECTION DRAIN VALVE W/HOSE THREADED CONN. SUPPLY AIR UP OR IN SECTION AIR COOLED CONDENSER AIR CONDITIONING UNIT ADJUSTABLE ABOVE FINISHED FLOOR AIR HANDLING UNIT ACCESS PANEL AIR PRESSURE DROP(IN WC) AIR SEPARATOR BOILER AIR BLENDER BACKDRAFT DAMPER BRAKE HORSEPOWER BRITISH THERMAL UNITS BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM OF STEEL BACKWATER VALVE CAPACITY CENTER TO CENTER CUBIC FEET PER MINUTE CHILLER CHILLED WATER RETURN CHILLED WATER SUPPLY CAST IRON CENTER LINE CEILING CLEANOUT CONNECTION CHLORINATED POLYVINYL CHLORIDE CONDENSER WATER RETURN CONDENSER WATER SUPPLY CONDENSING UNIT CABINET UNIT HEATER CONTROL VALVE DRAIN DIAMETER DRY BULB TEMPERATURE DISCONNECT DOWN DOWNSPOUT DISHWASHER DUCT SMOKE DETECTOR SUPPLY DUCT SMOKE DETECTOR RETURN EXHAUST AIR DEVICE EXHAUST AIR ENTERING AIR TEMPERATURE ENTERING DRY BULB TEMPERATURE ENTERING WET BULB TEMPERATURE ENTERING WATER TEMPERATURE EFFICIENCY EXPANSION TANK ELECTRIC CABINET HEATER EXHAUST FAN ELECTRICAL CONTRACTOR ENERGY MANAGEMENT SYSTEM EXTERNAL STATIC PRESSURE EMERGENCY SHUT-OFF VALVE ELECTRIC UNIT HEATER ELECTRIC WATER HEATER EXISTING EXHAUST FRESH AIR FAN COIL UNIT FLOOR DRAIN FLOOR HYDRANT FILTER DRIER FINISH FLOOR FACTORY MOUNTED FEET PER MINUTE FEET FURNISHED FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE PROTECTION CONTRACTOR FLOOR SINK FAN TERMINAL UNIT GALLONS GALVANIZED GREASE INTERCEPTOR GENERAL CONTRACTOR GAS UNIT HEATER GAS WATER HEATER COLD WATER HOSE BIBB HUB DRAIN HOUR HORSEPOWER IE IN INST IRH LAT LDB LWB LWT LRA LPG LWCO MAU MAX MBH MC MCC MD MIN MSB MV NO NC NO. NF NTS OA OED OV P PC POC PIB PD PVC RA R-# RD RF RPM RP RPBP RTU RV S-# SA SD SF SW STL SG SP SPC SV TC TDV T TF TS TSP TXV UH UR V VAV VD VFD VTR WB WPD W.C. ZD INVERT ELEVATION INCHES INSTALLED INFRA-RED HEATER LEAVING AIR TEMPERATURE LEAVING DRY BULB TEMPERATURE LEAVING WET BULB TEMPERATURE LEAVING WATER TEMPERATURE LOCKED ROTOR AMPS LIQUID PROPANE GAS LOW WATER CUT-OFF MAKE-UP AIR UNIT MAXIMUM 1000 BTU/HR MECHANICAL CONTRACTOR MOTOR CONTROL CENTER MOTORIZED DAMPER MINIMUM MOP SERVICE BASIN MIXING VALVE NORMALLY OPEN NORMALLY CLOSED NUMBER NON-FUSED NOT TO SCALE OUTSIDE AIR OPEN END DUCT OUTLET VELOCITY PUMP PLUMBING CONTRACTOR POINT OF CONNECTION POWER INDUCTION BOX PRESSURE DROP POLYVINYL CHLORIDE RETURN AIR RETURN AIR DEVICE ROOF DRAIN RELIEF FAN REVOLUTIONS PER MINUTE RECIRCULATING PUMP REDUCED PRESSURE BACK FLOW PREVENTER ROOF TOP UNIT RELIEF VALVE SUPPLY AIR DEVICE SUPPLY AIR SMOKE DAMPER SUPPLY FAN SWITCH STEEL SIGHT GLASS STATIC PRESSURE SPRINKLER CONTRACTOR SOLENOID VALVE TEMPERATURE CONTROLLER TRIPLE DUTY VALVE TRANSFER GRILLE TRANSFER FAN TAMPER SWITCH TOTAL STATIC PRESSURE THERMAL EXPANSION VALVE UNIT HEATER (HYDRONIC) URINAL VENT VARIABLE AIR VOLUME BOX VOLUME DAMPER VARIABLE FREQUENCY DRIVE VENT THRU ROOF WET BULB TEMPERATURE WATER PRESSURE DROP(FT. H20) WATER COLUMN ZONE DAMPER 1. SEE THIS SHEET FOR SYMBOLS AND ABBREVIATIONS. 2. THESE GENERAL NOTES APPLY TO ALL DEMOLITION WORK. 3. REMOVE DUCTS AND EQUIPMENT SHOWN CROSS HATCHED OR DASHED. 4. CONTRACTOR SHALL USE CAUTION WHEN REMOVING DUCTS TO AVOID DAMAGE TO ELECTRICAL WIRING THAT IS TO REMAIN. NOTIFY GC AND EC IF WIRING IS FOUND ATTACHED TO DUCTWORK. 5. WHEREVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE TO BE REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGERS, FOUNDATIONS, ETC., UNLESS NOTED OTHERWISE. AFTER REMOVAL; FLOORS, WALLS AND CEILINGS SHALL BE PATCHED AND FINISHED TO MATCH ADJOINING SURFACES. 6. MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 314.361.0000 ph 314.361.9191 fax IOWA 1000 Melrose Avenue Iowa City, IA 52246 WHERE ITEMS ARE REMOVED, UTILITIES AND THE AREA FROM WHICH THE ITEMS HAVE BEEN REMOVED SHALL BE LEFT IN SUCH A MANNER THAT IS SAFE FOR BOTH PEOPLE AND PROPERTY ON A DAILY BASIS. 319.343.7055 ph hkwarchitects.com 7. THESE DRAWINGS MAY NOT FULLY DEPICT ALL AS-BUILT CONDITIONS, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS. NOTIFY THE ENGINEER AT ONCE SHOULD A DISCREPANCY OR OMISSION BE FOUND. 8. SEE ARCHITECTURAL DRAWINGS FOR ARCHITECTURAL DEMOLITION. REFER TO MEP AND SPRINKLER DEMOLITION PLANS FOR MEP AND SPRINKLER DEMOLITION. 9. THE OWNER WILL BE RESPONSIBLE FOR THE REMOVAL OF ANY ACMs (ASBESTOS CONTAINING MATERIALS, PCBs OR OTHER HAZARDOUS MATERIALS) PRESENTLY EXISTING WITHIN THE AREAS AFFECTED BY THE PROJECT SCOPE, THAT WOULD BE REQUIRED TO BE REMOVED FOR THE WORK. ABATEMENT WORK, IF REQUIRED, IS NOT PART OF THIS CONTRACT. 18207 Edison Avenue Chesterfield, M0 63005 636.530.7770 ph 636.530.7877 fax MECHANICAL GENERAL RENOVATION NOTES: 1. SEE THIS SHEET FOR SYMBOLS AND ABBREVIATIONS. 2. THESE GENERAL NOTES APPLY TO ALL WORK. 3. DUCT SIZES SHOWN ARE SHEET METAL SIZE AND INCLUDE THE DUCT LINER WHERE LINER IS REQUIRED. 4. ALL SUPPLY, RETURN, EXHAUST, AND TRANSFER REGISTERS IN ROOMS WITHOUT CEILINGS SHALL BE 9'-0" AFF UNLESS NOTED OTHERWISE. 5. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF CEILING AIR DEVICES. 6. MAINTAIN 10'-0" MINIMUM BETWEEN OUTSIDE AIR INTAKES AND ALL EXHAUST FANS, FLUES, PLUMBING VENTS, ETC. 7. ALL DUCT RUN OUTS TO AIR DEVICES SHALL HAVE A DAMPER WITH A LOCKING QUADRANT IN ADDITION TO THE DAMPER IN THE NECK OF THE AIR DEVICE. 8. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO PREVENT THE INSTALLATION OF CONDUITS, PIPING, LIGHTING, OR OTHER OBSTRUCTIONS UNDER OR ADJACENT TO HVAC EQUIPMENT THAT OBSTRUCTS ACCESS TO COILS, MOTORS, VALVES, FILTERS, ETC., OR OTHER HVAC COMPONENTS NEEDING MAINTENANCE OR OPERATIONS ACCESS. 9. FLEXIBLE DUCT LENGTH SHALL NOT EXCEED 3'-0". 10. ALL EXPOSED DUCTS SHALL HAVE PAINT GRIP FINISH FOR PAINTING BY GC. COLOR PER ARCHITECT. 11. THERMOSTATS AND ROOM TEMPERATURE SENSORS SHALL BE MOUNTED AT 4'-0" TO THE TOP OF THE JUNCTION BOX THAT THE DEVICE IS MOUNTED ON. 12. COORDINATE DUCTWORK WITH ALL SPRINKLER AND PLUMBING PIPING BEFORE COMMENCEMENT OF WORK. 13. MAINTAIN MINIMUM OF 4'-0" BETWEEN BRANCH TAKE OFFS. 14. LOCATIONS OF NEW EQUIPMENT, DUCTWORK, PIPING, AND ASSOCIATED ITEMS SHOWN ON THE DRAWINGS ARE SCHEMATIC. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION AND ELEVATION OF ALL WORK. PROVIDE OFFSETS, FITTINGS, TRANSITIONS, EXTENSIONS, ETC., REQUIRED FOR A COMPLETE SYSTEM. 15. NO CHANGES IN CONTRACT PRICE WILL BE ALLOWED FOR MINOR CHANGES IN LAYOUT OR LOCATION REQUIRED TO AVOID INTERFERENCES, OBSTRUCTIONS, ETC. CONTRACT PRICE CHANGES WILL BE CONSIDERED ONLY FOR CHANGES IN THE SCOPE OF THE PROJECT REQUIREMENTS. ALL SUCH SCOPE CHANGES AND PRICE REVISIONS MUST BE AUTHORIZED IN WRITING. NOTIFY THE ENGINEER AT ONCE SHOULD A DISCREPANCY OR OMISSION BE FOUND. 16. ALL UTILITIES SERVING EXISTING AREAS SHALL REMAIN IN SERVICE AT ALL TIMES EXCEPT FOR SHORT PERIODS OF INTERRUPTION FOR TIE IN OF NEW SERVICES TO EXISTING. ALL INTERRUPTIONS SHALL BE SCHEDULED WITH OWNER AND SHALL NOT BE SCHEDULED UNTIL NEW SERVICES ARE COMPLETE AND READY FOR FINAL CONNECTION. PRESSURE RELIEF VALVE 17. AIR DEVICES SHALL BE SIZED TO MATCH THE CEILING GRID. FURNISH AIR DEVICES FOR EITHER REGULAR GRID CEILINGS OF FOR NARROW GRID CEILINGS OR FOR BOTH TYPES OF GRID; COORDINATE WITH THE ARCHITECTURAL REFLECTED CEILING PLANS. 3-WAY AUTOMATIC CONTROL VALVE 18. PROVIDE SUPPLEMENTAL "TEES" FOR THE CEILING GRID WHERE DIFFUSERS ARE A DIFFERENT SIZE THAN THE CEILING TILES. 2-WAY AUTOMATIC CONTROL VALVE 19. WHERE INSULATION CONTAINING HAZARDOUS MATERIALS HAS BEEN REMOVED FROM DUCTWORK, PIPING, OR EQUIPMENT, REPLACE IT WITH NEW INSULATION. SEE SPECIFICATIONS FOR TYPE AND THICKNESS. VOLUME DAMPER MOTORIZED VALVE 20. GENERALLY PROVIDE DUCT INSULATION FOR SUPPLY, RETURN AND OUTSIDE AIR DUCTS ABOVE CEILINGS. SEE DETAILS AND DUCT INSULATION SCHEDULE ON PLANS FOR ADDITIONAL REQUIREMENTS. SEE SPECS 230900 AND 230200 FOR A MORE DETAILED DESCRIPTION OF LINING AND INSULATION REQUIREMENTS. MOTORIZED DAMPER ANGLE VALVE 21. ALL DUCTS SHALL BE 2" WG PRESSURE CLASS. RETURN,EXHAUST OR OUTSIDE AIR UP OR IN SECTION SUPPLY AIR DOWN OR AWAY RETURN,EXHAUST OR OUTSIDE AIR DOWN OR AWAY RECTANGULAR ELBOW WITH TURNING VANES M M SV FIRE DAMPER/SMOKE DAMPER/COMB. FIRE SMOKE DAMPER SOLENOID VALVE SPIN-IN FITTING WITH DAMPER (SIDE) THERMAL EXPANSION VALVE TEMPERATURE/PRESSURE TEST PLUG Bid Set D EQUIPMENT IDENTIFICATION ACC AC ADJ AFF AHU AP APD AS B BB BDD BHP BTU BOD BOP BOS BW CAP CC CFM CH CWR CWS CI CL CLG CO CONN CPVC CR CS CU CUH CV D DIA DB DISC DN DS DW DSD DSR E-# EA EAT EDB EWB EWT EFF ET ECH EF EC EMS ESP ESV EUH EWH EX EXH FA FCU FD FH FDR FIN FLR FM FPM FT FURN FLA FOB FOT FPC FS FTU GAL GALV GI GC GUH GWH CW HB HD HR HP ROUND TAP WITH DAMPER (BOTTOM) MECHANICAL GENERAL DEMOLITION NOTES: 912 Meramec Station Road, Valley Park, MO 63021 AHU 1 X - EXISTING S - SUPPLY R - RETURN E - EXHAUST PNC Valley Park AIR DEVICE TAG CFM S1 # MECHANICAL ABBREVIATIONS MECHANICAL SYMBOLS LEGEND (CONT.) PNC Bank MECHANICAL SYMBOLS LEGEND Revision Schedule No Date Description Seismic Use Group ( II ) LISTING OF EQUIPMENT AND SYSTEM COMPONENTS Seismic Design Category ( D ) ANCHORAGE TO FLOORS, ROOFS, ETC. Not Provided Provided SWAY BRACING Not Provided Provided LOCATION OF PROFESSIONALLY SEALED ANCHORAGE AND SWAY BRACING DETAILS Drawing No. or Spec. Section Shop Drawings COMMENTS Separate Permit & Plans AIR DEVICES X X 2 EH-1 X X X 12 DUCTWORK X 4 X EF-1 (EXHAUST FAN) X 1. The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. X X 12 TABLE 4.4, ITEM 1, A, EXCEPTION FOR 3 FEET MINIMUM OF FLEX CONNECTION BETWEEN COMPONENTS, MOUNTED 4 FEET OR LESS ABOVE THE FLOOR LEVEL AND WEIGHS 400 POUNDS OR LESS. TABLE 4.4, ITEM 1, B, EXCEPTION FOR 3 FEET MINIMUM OF FLEX CONNECTION BETWEEN COMPONENTS AND WEIGHS 20 POUNDS OR LESS. TABLE 4.4, ITEM 1, B, EXCEPTION FOR LESS THAN 5LB/FT (COPPER PIPING - 2-1/2" OR LESS, SCHEDULE 40 AND 80 CPVC - 3" OR LESS). 3 FOOT FLEX CONNECTIONS FOR SUSPENDED EQUIPMENT. TABLE 4.4, ITEM 3, EXCEPTION FOR DUCTWORK "A" (OR "B"). REFER TO INSTALLATION DETAIL ON DRAWING #__. TABLE 4.4, ITEM 4, EXCEPTION FOR PIPING SUSPENDED FROM HANGERS 12 INCHES OR LESS. REFER TO INSTALLATION DETAIL ON DRAWING #__. TABLE 4.4, ITEM 4, EXCEPTION FOR DUCTILE PIPING 1" OR LESS (SEISMIC DESIGN CATEGORY D). DUCTILE PIPING, STEEL, COPPER PIPING AND TUBING JOINED BY WELDING, BRAZING/SOLDERING OR FLANGES. REFER TO TABLE 4.4, ITEM 4. TABLE 4.4, ITEM 4, EXCEPTION FOR DUCTILE PIPING 3" OR LESS (SEISMIC DESIGN CATEGORY D). TABLE 4.4, ITEM 5, EXCEPTION FOR EXTERIOR GAS PIPING ON ROOF, 2 PSI OR LESS: SEISMIC SHUT-OFF VALVE OR FLEX CONNECTORS WITHIN 5 FEET OF THE BEGINNING OF THE RUN, AT CONNECTIONS TO EQUIPMENT AND AT 42 FOOT OR LESS INTERVALS. COMPONENTS SHALL BE POSITIVELY ATTACHED WITH MECHANICAL FASTENERS. SEISMIC CALCULATIONS ARE ATTACHED TO SET OF DRAWINGS. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO THE PLAN REVIEWER. TYPICAL SEISMIC ANCHORAGE (OR SWAY BRACING) IS PROVIDED ON THE DRAWINGS FOR REFERENCE ONLY. SHOP DRAWINGS ARE REQUIRED. MECHANICAL SHEET LIST Sheet Number Sheet Name M0.1 MECHANICAL SYMBOLS, ABBREVIATIONS & GENERAL NOTES M0.2 MECHANICAL SCHEDULES & DETAILS M1.1 MECHANICAL DUCTWORK PLAN SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION Anchorage & Sway Bracing - Mechanical & Plumbing System Components April 11, 2016 16.008.00 MECHANICAL SYMBOLS, ABBREVIATIONS & GENERAL NOTES M0.1 Copyright 2016 HKW Architects EXHAUST FAN SCHEDULE ELECTRIC HEATER SCHEDULE (CEILING) MARK MANUFACTURER EH-1 QMARK MODEL NO. CDF548 LOCATION ATM / VESTIBULE WATTS VOLT/PH REMARKS 4000 208/1 1,2,3 1. UNIT MOUNTED DISCONNECT SWITCH. 2. CEILING MOUNTED. 3. THERMOSTAT TO BE MOUNTED ON WALL. SEE SHEET M1.1 FOR LOCATION. MARK MANUFACTURER MODEL NO. LOCATION DRIVE SERVICE CFM SP RPM VOLTS/PH HP REMARKS EF-1 BROAN L150MG CEILING DIRECT JANITOR CLOSET 100 0.350 1,750 120/1 - 1 EF-2 BROAN L150MG CEILING DIRECT RESTROOM 100 0.350 1,750 120/1 - 1 EF-3 BROAN L150MG CEILING DIRECT RESTROOM 100 0.350 1,750 120/1 - 1 1. SPEED CONTROLLER AND BACKDRAFT DAMPER. MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 ROOF TOP UNIT SCHEDULE (EXISTING TO REMAIN) 314.361.0000 ph 314.361.9191 fax ESP INCHES H2O HEATING INPUT MBH HP V/PH MCA ELECTRICAL MARK MANUFACTURER MODEL NO. TONS CFM O.A. CFM RTU-1 YORK D2NA060N11025D 5 1,850 260 0.5 135 1.0 208/3 29.5 1 RTU-2 YORK D1NA048N11025C 4 1,500 100 0.5 135 1.0 208/3 25.9 1 1. REMARKS IOWA 1000 Melrose Avenue Iowa City, IA 52246 319.343.7055 ph hkwarchitects.com EXISTING RTU UNIT. NO MODIFCATION OR UPGRADES REQUIRED TO UNIT OR ASSOCIATED GAS PIPING. 18207 Edison Avenue Chesterfield, M0 63005 AIR DEVICE SCHEDULE PLAN MARK MANUFACTURER MODEL MATL. NECK SIZE FRAME TYPE PANEL SIZE NC COLOR REMARKS S1 KRUEGER PLQ STEEL 8"Ø LAY-IN 24x24 <30 44-BRITISH WHITE 1,2 1,2 S2 KRUEGER PLQ STEEL 10"Ø LAY-IN 24x24 <30 44-BRITISH WHITE S3 KRUEGER 5810 ALUM 22x22 SURFACE 12x12 <30 10-ALUMICAN 1,2 S4 ACUTHERM TF-HC STEEL 8"Ø LAY-IN 24x24 <30 STANDARD WHITE 1,2,5 T1 KRUEGER 5810 ALUM 22x22 SURFACE 12x12 <30 10-ALUMICAN 1,2 R1 KRUEGER S80H STEEL 22x22 LAY-IN 24x24 - 44-BRITISH WHITE 1,2,3,4 636.530.7770 ph 636.530.7877 fax Bid Set 912 Meramec Station Road, Valley Park, MO 63021 PNC Valley Park PNC Bank 1. VERIFY ARRANGEMENT WITH CEILING TYPE 2. DAMPERS TO BE RADIAL OPPOSED BLADE 3. DROPPED FACE RETURN GRILLE 4. PROVIDE NECK ADAPTER MATCHING SIZE ON DRAWING 5. VARIABLE VOLUME DIFFUSER. SUPPORTED BY DUCT IN OPEN CEILING. Revision Schedule BRANCH DUCT SEAL FLEX DUCT INSULATION TO RIGID DUCT INSULATION WITH DUCT TAPE EXTERNAL DUCT INSULATION SQUARE TO ROUND TRANSITION The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. VOLUME DAMPER WITH LOCKING QUADRANT AND INSULATION EXTENSION DRAWBAND SEE NOTE 2 FLEXIBLE ROUND DUCT, SEE SPECS NOTES: 1. THIS DETAIL IS APPLICABLE FOR FELXIBLE ROUND DUCT TAKE-OFFS FROM BRANCH DUCTS TO DIFFUSERS. 2. FLEXIBLE DUCT INSULATION SHALL TERMINATE AT SIDE OF BRANCH DUCT SO NO UNISULATED METAL PARTS ARE EXPOSED. BOTTOM TAP DIFFUSER DETAIL BRANCH CONNECTION TO DIFFUSER DETAIL FLEXIBLE DUCT CONNECTION TO BRANCH - INSULATED SOUND BO0T DETAIL NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION No Date Description April 11, 2016 16.008.00 MECHANICAL SCHEDULES & DETAILS M0.2 Copyright 2016 HKW Architects MECHANICAL GENERAL NOTES: 1. REFER TO SHEET M0.1 FOR SYMBOLS, ABBREVIATIONS AND GENERAL CONSTRUCTION NOTES. 2. ADJACENT TENANT SPACE NOT IN SCOPE. 3. ITEMS SHOWN DASHED OR CROSS HATCHED TO BE DEMOLISHED. 4. MC SHALL PROVIDE COMMISIONING FOR THE HVAC SYSTEM BEFORE SUBSTANTIAL COMPLETION. CONFIRM CONTROLS OPERATION; RTU OPERATION - FAN, DAMPERS, COOLING STAGING, HEATING STAGING; EF OPERATION; EH OPERATION. SUBMIT REPORT TO OWNER. MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 314.361.0000 ph 314.361.9191 fax - XS 1 - XS 1 12"ø 16"ø 9 FD 12"ø XS - XS - XS 1 - XS RTU 1 - 1X 8"ø 10"ø 1X 100 2 R1 8"ø S2 T 8"ø 12"x12" 350 S2 - 12"ø - 1 - 16"ø XS XS 1 1 - 350 S1 1 XS RTU 2X (ON ROOF) - R1 S1 - 100 10"ø 12"ø XS 10"ø R1 - 8"ø Lobby 119 RTU S1 200 2X S1 200 (ON ROOF) - 1 9 - XT XT - - 9 3 3 EF EF S2 EX EX 350 8"ø 8"ø Office 116 S1 Office 118 The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. 636.530.7770 ph 636.530.7877 fax 6 12" X 12" TRANSFER DUCT SHALL TRANSITION UP AND TERMINATE IN CEILING PLENUM OF LOBBY. 7 8" TWO-POSITION, 120 VOLT CONTROL DAMPER. LINE VOLTAGE, DUCT MOUNTED THERMOSTAT SHALL CLOSE DAMPER WHEN SUPPLY AIR ABOVE 80° F. 8 PROVIDE DUCTED SOUND BOOT AT PLENUM RETURN GRILLES, SEE SHEET M0.2. 9 EXISTING WALL TRANSFER GRILLE AT 12' AFF TO BE REMOVED TO ACCOMMODATE NEW LAY-IN CEILING. 10 NEW WALL TRANSFER GRILLE AT 7' AFF. 11 EXISTING DUCT DETECTOR TO REMAIN. 12 12" x 12" TRANSFER DUCT ABOVE CEILING. 150 - 8"ø S1 150 6"ø 100 - EF S4 Break Room 109 S1 Self-Serve Boxes 114 8"ø Elec/Data 105 Janitor 107 12 12"x12" RTU-1X Office 115 Maintenance 104 150 T R1 S1 - 150 S1 150 100 Coupon Booth 112 S1 8"ø 100 Toilet 108 Passage 111 4 Toilet 106 EF EF 1 2 4 Revision Schedule T1 No - MECHANICAL DUCTWORK PLAN - DEMOLITION MECHANICAL DUCTWORK PLAN - RENOVATION SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" NORTH R1 Off-Stage 103 8"ø 8"ø 8"ø Office 117 S1 150 8"ø 8 (TYP) 10 NORTH INSTALL SIDE WALL AIR DEVICE 10' AFF. R1 Customer Pantry 113 16"x16" R1 T 5 3 R1 14"x16" RTU-2X 18207 Edison Avenue Chesterfield, M0 63005 S1 R1 1 - NEW EXHAUST FAN TO CONNECT TO EXISTING CAPPED VENT THROUGH ROOF. 12 8"ø - 150 1 FD 12 - 10"ø XS 20"x20" 16"ø 2 T RTU-2X RTU-1X XS RTU 8"ø (ON ROOF) (ON ROOF) XS 12"x12" Concierge 102 8"ø 12"x12" 1 4 4 T1 1 DEMOLISH EXISTING EXHAUST FAN AND DUCT TO EXISTING VENT THROUGH ROOF. VENT THROUGH ROOF TO REMAIN. 8"ø S1 6 3 hkwarchitects.com 150 1 5 RELOCATE EXISTING THERMOSTAT TO NEW LOCATION. SEE RENOVATION PLAN. Bid Set XS - 2 912 Meramec Station Road, Valley Park, MO 63021 11 319.343.7055 ph PNC Valley Park XT DEMOLISH EXISTING AIR DEVICE. PATCH DUCT TO REMAIN WHERE APPLICABLE. PNC Bank - 150 1 S1 EH-1 ATM Vestibule T 100 S3 EH 5 350 1 XT S1 100 20"x20" 9 S1 - IOWA 1000 Melrose Avenue Iowa City, IA 52246 SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION 4 R1 MECHANICAL KEYED NOTES: Date Description April 11, 2016 16.008.00 MECHANICAL DUCTWORK PLAN M1.1 PLUMBING GENERAL DEMOLITION NOTES: PLUMBING FIXTURE SCHEDULE Anchorage & Sway Bracing - Plumbing System Components MARK Seismic Use Group ( II ) Seismic Design Category ( D ) ANCHORAGE TO FLOORS, ROOFS, ETC. LISTING OF EQUIPMENT AND SYSTEM COMPONENTS Not Provided Provided SWAY BRACING Not Provided Provided LOCATION OF PROFESSIONALLY SEALED ANCHORAGE AND SWAY BRACING DETAILS Drawing No. or Spec. Section Shop Drawings EF-21-318 L/R 2a VENT PIPING 4. 5. X 2c 6. AMERICAN STANDARD "LUCERNE", VITREOUS CHINA, 20-1/2"x18-1/4", WALL-HUNG, FRONT OVERFLOW LAVATORY, 2-1/8" DIA. HOLES FOR CONCEALED ARMS. SINGLE CENTERSET. BASYS IR SERIES FAUCET.ONS SINGLE LEVER LAVATORY FAUCET WITH GRID STRAINER DRAIN ASSEMBLY, SINGLE CENTERSET, 0.5 GPM AERATOR. LFBV2166 Z1231-SL-79 EWC-1 MCGUIRE OPEN-GRID DRAIN. RUBBER WASHER AND BRASS LOCKNUT. WITH 1-1/2" TAILPIECE. S-1 ELECTRIC WATER HEATER SCHEDULE EWH-1 A.O. SMITH DEL-6 6 10 GPH HEAT CAP. REMARKS 100 120V 2500 WATTS 1 ELECTRIC WATER COOLER MCGUIRE CHROME PLATED, BRASS BODY P-TRAP WITH CLEANOUT, 17 GAUGE TUBULAER WALL BEND, CAST BRASS SLIP NUTS. LRADQ2521 HEAT SOURCE CONCEALED ARM SYSTEM FOR WALL LAVATORY. 8912 LFBV02 °F. RISE LAV GUARD 2 FAST FIT UNDERSINK PIPING COVERS FOR P-TRAP, ANGLE STOPS, AND SUPPLY COVERS. ADA COMPLIANT. ELKAY BI-LEVEL ELECTRIC WATER COOLER WITH BOTTLE FILLING STATION. VANDAL RESIST STREAMSAVER EZH20 BOTTLE FILLING - WATER COOLER COMBINATION KIT. SR1912A C STORAGE GAL. RECOVERY MCGUIRE CHROME PLATED, BRASS BODY P-TRAP WITH CLEANOUT, 17 GAUGE TUBULAER WALL BEND, CAST BRASS SLIP NUTS. 8912 9. THE OWNER WILL BE RESPONSIBLE FOR THE REMOVAL OF ANY ACMs (ASBESTOS CONTAINING MATERIALS, PCBs OR OTHER HAZARDOUS MATERIALS) PRESENTLY EXISTING WITHIN THE AREAS AFFECTED BY THE PROJECT SCOPE, THAT WOULD BE REQUIRED TO BE REMOVED FOR THE WORK. ABATEMENT WORK, IF REQUIRED, IS NOT PART OF THIS CONTRACT. 18207 Edison Avenue Chesterfield, M0 63005 636.530.7770 ph 636.530.7877 fax 10. MEP DEMOLITION WORK: VERIFY EXISTING SERVICES TO REMAIN. ALL NECESSARY CARE SHALL BE TAKEN DURING DEMOLITION TO PREVENT DAMAGE TO PLUMBING, ELECTRICAL, AND MECHANICAL SYSTEMS TO REMAIN. DUCTWORK, PIPING, ELECTRICAL LINES, AND PLUMBING SERVING OTHER AREAS SHALL PROVIDE FOR UNINTERRUPTED SERVICE TO THOSE AREAS UNLESS PRIOR WRITTEN APPROVAL IS RECEIVED FROM THE OWNER. COORDINATE ALL SUCH WORK WITH THE GENERAL CONTRACTOR AND OWNER'S ON SITE REPRESENTATIVE. 11. WASTE PIPING TO BE PVC WITH PLENUM WRAP OR CAST-IRON TO BE INSTALLED IN RETURN AIR PLENUM. PLUMBING GENERAL RENOVATION NOTES: CHICAGO FAUCET DECK MOUNTED WIDESPREAD FAUCET WITH BLADE HANDLES, 8" HIGH ARC SWING SPOUT WITH 1.0 GPM AERATOR (E3JKABCP). 1. SEE SHEET P0.1 FOR SYMBOLS AND ABBREVIATIONS. THESE GENERAL NOTES APPLY TO ALL WORK. 2. THESE DRAWINGS MAY NOT FULLY DEPICT ALL AS-BUILT CONDITIONS, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS. NOTIFY THE ENGINEER AT ONCE SHOULD A DISCREPANCY OR OMISSION BE FOUND. 3. PIPING ON PLANS IS SHOWN FOR GENERAL ARRANGEMENT. SEE DETAILS FOR CONNECTIONS TO UNITS. 4. WHERE PIPE SIZES ARE NOT SHOWN ON PLANS, SEE SIZES SHOWN ON ISOMETRICS. IF PIPE SIZES ON PLANS CONFLICT WITH SIZES SHOWN ON ISOMETRIC DIAGRAMS, SIZES ON DIAGRAMS SHALL TAKE PRECEDENCE. 5. SLOPE ALL SANITARY PIPES SMALLER THAN 4" AT 1/4" PER FT. AND SANITARY PIPES 4" OR LARGER AT 1/8" PER FT. UNLESS OTHERWISE INDICATED. 6. CONTRACTOR SHALL COORDINATE WITH OTHER TRADES TO PREVENT THE INSTALLATION OF CONDUITS, PIPING, LIGHTING, OR OTHER OBSTRUCTIONS UNDER OR ADJACENT TO HVAC EQUIPMENT THAT OBSTRUCTS ACCESS TO COILS, MOTORS, VALVES, FILTERS, ETC., OR OTHER HVAC COMPONENTS NEEDING MAINTENANCE OR OPERATIONS ACCESS. 7. CONTRACTOR SHALL COORDINATE EXACT LOCATION OF FLOOR DRAINS WITH ARCHITECTURAL AND STRUCTU PLANS. 8. COORDINATE PLUMBING WITH ALL MECHANICAL DUCTWORK AND PIPING AND SPRINKLER PIPING BEFORE COMMENCEMENT OF WORK. 9. LOCATIONS OF NEW FIXTURES, EQUIPMENT, PIPING, AND ASSOCIATED ITEMS SHOWN ON THE DRAWINGS ARE SCHEMATIC. CONTRACTOR SHALL SEE ARCHITECTURAL PLANS AND FIELD VERIFY EXACT LOCATION AND ELEVATION OF ALL WORK. PROVIDE OFFSETS, FITTINGS, TRANSITIONS, EXTENSIONS, ETC., REQUIRED FOR A COMPLETE SYSTEM. BRASS CRAFT LOOSE KEY, CHROME PLATED ANGLE STOP, WITH 1/2" SWEAT INLET AND 3/8" O.D. COMPRESSION OUTLET WITH 3/8" x 11-1/2" LONG RISER AND SHALLOW CHROME PLATED WALL ESCUTCHEON. MCGUIRE CHROME PLATED, BRASS BODY WITH CLEANOUT, 17 GAUGE TUBULAER WALL BEND, CAST BRASS SLIP NUTS. MOP SERVICE BASIN WSB-1 319.343.7055 ph hkwarchitects.com ELKAY, 25"x21.25" STAINLESS STEEL SINGLE BOWL SINK, 6" DEEP, HEAVY DUTY SOUND GUARD UNDERCOATING. 8" CENTERSET. MSB-1 MIB1HAAB WHERE ITEMS ARE REMOVED, UTILITIES AND THE AREA FROM WHICH THE ITEMS HAVE BEEN REMOVED SHALL BE LEFT IN SUCH A MANNER THAT IS SAFE FOR BOTH PEOPLE AND PROPERTY ON A DAILY BASIS. SEE ARCHITECTURAL DRAWINGS FOR ARCHITECTURAL DEMOLITION. REFER TO MEP AND SPRINKLER DEMOLITION PLANS FOR MEP AND SPRINKLER DEMOLITION. 1. NON-SIMULTANEOUS OPERATION. T-35 IOWA 1000 Melrose Avenue Iowa City, IA 52246 SINK ELKAY 3-1/2" DIAMETER WASTE AND 1-1/2" TAILPIECE. 897-RCF 314.361.0000 ph 314.361.9191 fax MCGUIRE STOP VALVE, CONVERTIBLE LOOSE KEY HANDLE, LEAD FREE, CHROME PLATED. LK-18B EB-54 MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 WHEREVER EXISTING EQUIPMENT, PIPING, ETC., ARE TO BE REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGERS, FOUNDATIONS, ETC., UNLESS NOTED OTHERWISE. AFTER REMOVAL, FLOORS, WALLS AND CEILINGS SHALL BE PATCHED AND FINISHED TO MATCH ADJOINING SURFACES. 8. MCGUIRE LOOSE KEY CHROME PLATED, COMMERCIAL PATTERN QUARTER TURN BRASS BALL VALVE. LZSTL8WSVRSK 201-AGN8AE3-317ABCP MODEL NO. 7. 1 X TABLE 4.4, ITEM 1, A, lp=1.0, COMPONENT DOES NOT WEIGH MORE THAN 400 POUNDS AND FLEXIBLE CONNECTIONS ARE PROVIDED. TABLE 4.4, NOTE 2: a. THE FOLLOWING SANITARY DRAIN, WASTE AND VENT PIPE: SCHEDULE 40 PVC, 6 INCHES OR LESS IN DIAMETER, SCHEDULE 80 PVC, 4 INCHES OR LESS IN DIAMETER, SERVICE WEIGHT AND NO HUB CAST IRON, 2 INCHES OR LESS IN DIAMETER. b. THE FOLLOWING STORM DRAIN PIPE: SCHEDULE 40 AND 80 PVC, 3 INCHES OR LESS IN DIAMETER, SERVICE WEIGHT AND NO HUB CAST IRON, NOT APPLICABLE. c. THE FOLLOWING WATER PIPE: TYPE L AND M COPPER, 2-1/2 INCHES OR LESS IN DIAMETER, SCHEDULE 40 AND 80 CPVC, 3 INCHES OR LESS IN DIAMETER. d. FLEXIBLE CONNECTIONS ARE NOT REQUIRED FOR CONNECTIONS TO APPLIANCES OR PLUMBING FIXTURES THAT ARE MOUNTED TO WALLS OR FLOORS. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO SUBMITTAL TO THE PLAN REVIEWER. SEISMIC DETAILS ARE ATTACHED TO THE SET OF DRAWINGS. TYPICAL SEISMIC ANCHORAGE (OR SWAY BRACING) IS PROVIDED ON THE DRAWINGS FOR REFERENCE ONLY. SHOP DRAWINGS ARE REQUIRED. MNFG. CONTRACTOR SHALL USE CAUTION WHEN REMOVING PIPING, EQUIPMENT AND FIXTURES TO AVOID DAMAGE TO ELECTRICAL WIRING THAT IS TO REMAIN. NOTIFY GC AND EC IF WIRING IS FOUND ATTACHED TO PIPING. WALL HUNG LAVATORY 8912 MARK THESE DRAWINGS MAY NOT FULLY DEPICT ALL AS-BUILT CONDITIONS, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING BIDS. NOTIFY THE ENGINEER AT ONCE SHOULD A DISCREPANCY OR OMISSION BE FOUND. LAV-1 0356.137 #103 E-Z 3. 4. 5. 155A2 1. 2. DEMOLISH PIPING, FIXTURES, AND EQUIPMENT SHOWN CROSS HATCHED OR DASHED. GERBER FLOOR MOUNTED TANK TYP VITREOUS CHINA TOILET. ELONGATED BOWL, ADA COMPLIANT, 1.1 GAL PER FLUSH. WATER PIPING X 3. CHURCH COMMERCIAL WHITE SOLID PLASTIC OPEN FRONT SEAT, LESS COVER. EFX-375.100.0000 WATER HEATER (LESS THAN OR EQUAL TO 400 POUNDS) THESE GENERAL DEMOLITION NOTES APPLY TO ALL DEMOLITION WORK. 9500CT 2a X X 2. Separate Permit & Plans X X FLOOR MOUNTED WATER CLOSET - ADA SEE SHEET P0.1 FOR SYMBOLS AND ABBREVIATIONS. SEE RISER DIAGRAMS FOR ADDITIONAL DEMOLITION DETAILS. COMMENTS WASTE PIPING X WC-1 DESCRIPTION 1. Copyright 2016 HKW Architects STERN WILLIAMS ELFIN ONE PIECE, TERRAZO WITH GREY MARBLE CHIPS 24"x24" WITH 6" HIGH SIDES, MOP BASIN. DRAIN BODY SHALL BE STAINLESS STEEL OR CHROME PLATED BRASS, CAST INTEGRAL AND SHALL PROVIDE FOR A CAULK CONNECTION NOT LESS THAN 1" DEEP TO A 3" PIPE. STRAINER SHALL BE CHROME PLATED BRASS. CHICAGO WALL MOUNTED, 8" BODY FAUCET WITH ADJUSTABLE ARMS. STERN WILLIAMS HOSE AND WALL HOOK. WATER SUPPLY BOX GUY GRAY WATER SUPPLY BOX, 20 GAUGE STEEL FACEPLATE AND BOX WITH WHITE POWDER COATING, 1/4 TURN VALVE, 1/2" SWEAT CONNECTION, WITH LEAD FREE WATER HAMMER ARRESTER. 10. NO CHANGES IN CONTRACT PRICE WILL BE ALLOWED FOR MINOR CHANGES IN LAYOUT OR LOCATION REQUIRED TO AVOID INTERFERENCES, OBSTRUCTIONS, ETC. CONTRACT PRICE CHANGES WILL BE CONSIDERED ONLY FOR CHANGES IN THE SCOPE OF THE PROJECT REQUIREMENTS. ALL SUCH SCOPE CHANGES AND PRICE REVISIONS MUST BE AUTHORIZED IN WRITING. NOTIFY THE ENGINEER AT ONCE SHOULD A DISCREPANCY OR OMISSION BE FOUND. 11. PIPING IN EXPOSED LOCATIONS SHALL BE CHROME PLATED UNLESS OTHERWISE INDICATED. 12. CHROME PLATED ESCUTCHEONS SHALL BE PROVIDED AT ALL LOCATIONS WHERE PIPES PENETRATE WALLS IN EXPOSED LOCATIONS. 13. PROVIDE SEISMIC BRACING AS REQUIRED. SEE SCHEDULE FOR SPECIFICATIONS. WC 1 FIXTURE TYPE FIXTURE NUMBER CONNECTION OF NEW TO EXISTING D Bid Set PLUMBING SYMBOLS LEGEND PNC Valley Park PNC Bank 15. SPACES ABOVE CEILINGS ARE RETURN AIR PLENUMS UNLESS OTHERWISE INDICATED ON HVAC PLANS. PIPING AND INSULATION IN CEILING PLENUMS SHALL HAVE A FLAME SPREAD OF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 50 OR LESS AS DETERMINED IN ACCORDANCE WITH ASTM STANDARD E-84. 912 Meramec Station Road, Valley Park, MO 63021 14. ALL UTILITIES SERVING EXISTING AREAS SHALL REMAIN IN SERVICE AT ALL TIMES EXCEPT FOR SHORT PERIODS OF INTERRUPTION FOR TIE IN OF NEW SERVICES TO EXISTING. ALL INTERRUPTIONS SHALL BE SCHEDULED WITH OWNER, AND SHALL NOT BE SCHEDULED UNTIL NEW SERVICES ARE COMPLETE AND READY FOR FINAL CONNECTION. DRAIN Revision Schedule COLD WATER (CW) No Date Description HOT WATER SUPPLY (HW) S SOFT WATER H HARD WATER T TEMPERED WATER 140 G GW W 140 DEGREE HOT WATER GAS PIPING GREASE WASTE SANITARY WASTE ABOVE GRADE SANITARY VENT DT DRAIN TILE ST STORM DRAINAGE PIPING ABOVE GRADE OD OVERFLOW DRAINAGE PIPING ABOVE GRADE PIPING BELOW GRADE (SEE PLANS) PLUMBING TRAP PIPE TURNING DOWN PIPE TURNING UP WATER HAMMER ARRESTER BALL VALVE FLOW CONTROL/BALANCE VALVE PRESSURE RELIEF VALVE The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. CHECK VALVE GAS COCK UNION PRESSURE GAUGE STRAINER REDUCED PRESSURE BACKFLOW PREVENTOR (RPBFP) TP TRAP PRIMER AFF ABOVE FINISHED FLOOR NTS NOT TO SCALE CI CAST IRON CO CLEAN OUT THRU-FLOOR PLUMBING SHEET LIST Sheet Number Sheet Name P0.1 PLUMBING SYMBOLS, ABBREVIATIONS & GENERAL NOTES P1.1 PLUMBING WASTE & VENT PLAN P2.1 PLUMBING DOMESTIC PIPING PLAN SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION HOT WATER RETURN (REC) April 11, 2016 16.008.00 PLUMBING SYMBOLS, ABBREVIATIONS & GENERAL NOTES P0.1 Copyright 2016 HKW Architects PLUMBING GENERAL NOTES: 1. REFER TO SHEET P0.1 FOR SYMBOLS AND GENERAL NOTES. 2. PRIOR TO ANY SAWCUTTING OF THE FLOOR SLAB, CONTRACTOR SHALL XRAY THE FLOOR TO AVOID HITTING OTHER UTILITIES OR RE-BAR. COORDINATE EXACT ROUTE TO MINIMIZE DISTURBANCE TO FLOOR SLAB. REVIEW AND COORDINATE ALL SAWCUTTING WITH LANDLORD PRIOR TO WORK. MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 3. EXISTING VENT AND WASTE PIPING FROM EXISTING LAV AND WATER CLOSET IN RESTROOMS VENTED TO ROOF THROUGH TENANT WALL TO REMAIN. 314.361.0000 ph 314.361.9191 fax 4. ADJACENT TENANT SPACE NOT IN SCOPE. IOWA 1000 Melrose Avenue Iowa City, IA 52246 5. ITEMS SHOWN CROSS HATCHED TO BE DEMOLISHED. PLUMBING DEMOLITION KEYED NOTES: 319.343.7055 ph hkwarchitects.com 1 EXISTING FLOOR DRAIN TO BE REMOVED. PLUG AND CAP PIPE. PATCH FLOOR TO MATCH EXISTING FLOOR FINISH. 2 EXISTING MOP SERVICE BASIN TO BE REMOVED. PLUG AND CAP PIPE. PATCH FLOOR TO MATCH EXISTING FLOOR FINISH. 3 EXISTING VENT THROUGH ROOF. 18207 Edison Avenue Chesterfield, M0 63005 636.530.7770 ph 636.530.7877 fax PLUMBING RENOVATION KEYED NOTES: ATM Vestibule 100 1 4 EXISTING LAVATORY SHALL BE DISCONNECTED AND REMOVED. EXISTING ROUGH-IN SHALL REMAIN FOR NEW FIXTURE CONNECTIONS. 5 EXISTING WATER CLOSET SHALL BE DISCONNECTED AND REMOVED. EXISTING ROUGH-IN SHALL REMAIN FOR NEW FIXTURE CONNECTIONS. 6 CUT AND REMOVE EXISTING FLOOR TO INSTALL NEW WASTE PIPE BELOW SLAB. CONNECT TO EXISTING WASTE PIPING. PATCH FLOOR TO MATCH EXISTING FLOOR FINISH. Off-Stage 103 Concierge 102 FD 2" EX Break Room 109 2" PNC Bank 1 MSB 1 Janitor 107 Elec/Data 105 2 EWC 5 FD EX EX Customer Pantry 113 Office 118 LAV EX WC WC EX EX LAV EX MSB Office 117 Office 116 5 Office 115 Self-Serve Boxes 114 6 3" 1 6 2" 1 WC Toilet 106 Toilet 108 Revision Schedule WC No Date Description 1 1 LAV 4 1 FD EX 3 The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. EX LAV EX NORTH FD Passage 111 PLUMBING WASTE & VENT PLAN - DEMOLITION PLUMBING WASTE & VENT PLAN - RENOVATION SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" NORTH 3 SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION 4 FD Bid Set S Lobby 119 PNC Valley Park Maintenance 104 912 Meramec Station Road, Valley Park, MO 63021 6 April 11, 2016 16.008.00 PLUMBING WASTE & VENT PLAN P1.1 Copyright 2016 HKW Architects PLUMBING GENERAL NOTES: 1. REFER TO SHEET P0.1 FOR SYMBOLS AND GENERAL NOTES. 2. ADJACENT TENANT SPACE NOT IN SCOPE. 3. ITEMS SHOWN CROSS HATCHED TO BE DEMOLISHED. MISSOURI 5017 Washington Place Suite 200 St. Louis, M0 63108 PLUMBING DEMOLITION KEYED NOTES: 1 314.361.0000 ph 314.361.9191 fax DISCONNECT AND REMOVE EXISTING PLUMBING FIXTURE. REMOVE PIPING ROUGH-IN AND BRANCH PIPE BACK TO SUPPLY MAIN. CAP AT MAIN. IOWA 1000 Melrose Avenue Iowa City, IA 52246 2 DISCONNECT AND REMOVE EXISTING PLUMBING FIXTURE. EXISTING ROUGH-IN TO REMAIN FOR NEW CONNECT TO NEW PLUMBING FIXTURE. 3 1/2" hkwarchitects.com EXISTING ELECTRIC WATER HEATER ABOVE CEILING TO BE REMOVED. CONNECTIONS BRANCHING INTO ADJACENT SPACE TO BE CAPPED AND REMOVED. CONTRACTOR TO COORDINATE WITH LANDLORD TO VERIFY WATER SERVICE IS AVAILABLE WITH ADJACENT TENANT SPACE. 18207 Edison Avenue Chesterfield, M0 63005 1/2" 1/2" 1/2" 1/2" 1/2" 636.530.7770 ph 636.530.7877 fax PLUMBING RENOVATION KEYED NOTES: 1/2" 4 S 1/2" 6 1 WB 4 OPTIONAL1/2" COLD WATER PIPE TO SERVE TO COFFEE MAKER. CONTRACTOR TO BID AS SEPARATE LINE ITEM. SEE ARCHITECTURAL DRAWING FOR MOUNTING HEIGHT. 5 EXISTING PRV VALVE / SPACE MAIN WATER SUPPLY. ACCESS THROUGH RESTROOM CEILING ACCESS PANEL. 6 2-1/2" MAIN WATER SERVICE TO BUILDING WATER SUPPLY CONNECTION. 7 HOT AND COLD WATER PIPING TO EXISTING WATERCLOSETS AND LAVATORIES TO REMAIN. 8 EXISTING COLD WATER AND HOT WATER TO ADJACENT TENANT. DISCONNECT EXISTING WATER HEATER PIPING JOINING WITH THE ADJACENT SPACE WATER HEATER. PLUG / CAP SERVICE TO ADJACENT SPACE. 1 1/2" 1/2" 1/2" 319.343.7055 ph MSB 2 1/2" 1 7 EWC 1 EWH 1 8 3 PLUMBING DOMESTIC WATER ISOMETRIC NOT TO SCALE ATM Vestibule 100 Off-Stage 103 Concierge 102 S 6 Maintenance 104 1/2" 1/2" Janitor 107 4 Customer Pantry WB 113 1/2" 1 1/2" 1 2 2 MSB 1/2" EX LAV EX WC EX EWH EX WC EX LAV EX The Seal and Signature apply only to the Document to which they are Affixed, and Expressly Disclaim any Responsibility for all other Plans, Specifications, Estimates, Reports, or other Documents or Instruments relating to or intended to be used for any part or parts of the Architectural or Engineering Project. Copyright © 2016 by SSC Engineering, Inc. NORTH 3 Office 118 Office 116 Office 117 2 Office 115 Self-Serve Boxes 114 MSB 1 EWH 1 EWC Passage 111 1 7 7 Toilet 106 WC 1 LAV 1 Toilet 108 5 WC 1 LAV 2 1 PLUMBING DOMESTIC WATER PLAN - DEMOLITION PLUMBING DOMESTIC WATER PLAN - RENOVATION SCALE: 1/8" = 1'-0" SCALE: 1/8" = 1'-0" NORTH PNC Bank Elec/Data 105 2 1/2" Break Room 109 Revision Schedule 7 No Date Description 7 SSC JOB# 2016123_BID SET - NOT FOR CONSTRUCTION Lobby 119 PNC Valley Park 1 Bid Set FD 912 Meramec Station Road, Valley Park, MO 63021 FD April 11, 2016 16.008.00 PLUMBING DOMESTIC PIPING PLAN P2.1