Models: ACSP-3001-HW Compact 30A Surge Suppressor - hardwired Description This advanced surge suppressor provides the highest current capacity available in devices of its size to protect multiple pieces of sensitive electronic equipment on a single circuit. It features industrial strength “zero failure” technology backed by a ten year warranty. The compact body has a very low profile (1.75"H x 6"D x 9"W) and includes two mounting brackets for easy installation — on a wall behind a flat panel TV, under a counter, in a rack or just about anywhere. Terminates to 6-ft. non-metallic flexible whip that can be field-cut to shorter lengths. A blank plate with knockout allows the 30A receptacle to be converted to hardwired output if desired. Includes a 6-ft. non-metallic flexible whip and mounting brackets. Features • ETL Listed, ANSI C62.41 Compliant • Features (1) 30A outlet • Conforms to UL1449-3 • Includes blank cover plate with knockout that allows the 30A receptacle to be converted in the field to hardwired output, if needed • Low-profile chassis (1.75”H x 6”D x 9”W) • LEDs provide visual system status • Suppresses line to neutral with no ground contamination. • TCR technology defeats surges up to 72,000 amps with zero failures • Two mounting brackets allow versatile installation. • Optional mounting ears are available if standard 19” panel installation is preferred. • Terminates to 6-ft. non-metallic flexible whip • 10 year warranty Optional mounting ears (ACC-1ME) are available if standard 19” rackmount installation is preferred. Mechanical Specifications: Dimensions: Weight: Input Connections: Output Connections: Chassis: Mounting: Performance Specifications: Operating Voltage/Current: Maximum Surge Current: Initial Clamping Voltage: Endurance: Transient Noise Reduction: Response Time: Temperature Range: Protection Mode: UL1449-2 Adjunct Results: A & E Specifications The 30A single-circuit surge suppressor shall be Lowell model ACSP-3001-HW with one 30A outlet. It shall be ETL Listed and conform to UL1449 3rd edition. It shall meet ANSI C62.41 and protect the line to neutral without ground wire contamination. It shall be capable of protecting electronic equipment from transient voltages, spikes and surges up to 72,000 amps and have a response time of less than 5 nanoseconds. It shall mount with mounting brackets (included. It shall include LEDs for visual ground verification and surge diagnostics. Model No. Description ACSP-3001-HW ACC-1ME Compact surge suppressor Mounting Ears Spec. No. 1127 (rev. 06.04.13) pg. 1 of 2 Federal GSA specs (1996) Diagnostic LEDs (surge)** Applicable Standards: Safety Agency Approvals: 9"W x 1.75"H x 6"D 5 lbs. 6-ft. non-metallic flexible whip (1) 30A receptacle Steel with black powder epoxy finish (2) brackets 120VAC / 30A, 60Hz 72,000A (exceeds UL1449-3 6000V, 3000A) 205V, UL rating 400V IEEE C62.41-1991, B3 (C1), Pulses (lifetime): 1kv≥1,000,000; 3kv≥100,000; 6kv≥5000 29dB@100kHz, 70dB@1MHz Less than 5 nanoseconds 25˚C (77˚F) nominal Line to neutral, zero ground leakage 1000 surges, 6000 volts, 3000A, C1, and B3 waveforms (IEEE C62.41), NO FAILURES Grade A, Class 1, Mode 1 Top (green): ON = ground verified Center (green): ON = protection active Bottom (red): ON = protection reduced* UL1449-3, IEEE standard 587-80 A & B, IEEE standard C62.41-1991, IEC 1000-4-5-1995 (IEC 801-5). ETL Listed US and Canada **TCR surge suppression technology provides the assurance of Grade A, Class 1, Mode 1 endurance and performance testing plus visual diagnostic LEDs. The ground verified (green LED), protection active (green LED) should always be ON and the reduced protection (red LED) should be OFF. In the unlikely event the red LED illuminates, full suppression capability is NOT immediately or even necessarily compromised. The red LED indicates the overall life expectancy of the unit may be reduced. Contact Lowell for repair or replacement under the unit’s ten year warranty. Outlets Amperage Termination Over/Under Protection Remote Control Capable 1 30A hardwired No No ©2013 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069. Phone–800.325.9660 Fax—636.257.6606. Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. (lowellmfg.com) Top / Front Panel Layout Includes a 6-ft. non-metallic flexible whip and universal mounting brackets. Changing from receptacle output to hardwired output Remove cover, flip over and remove receptacle plate. Disconnect receptacle. Install blank knockout plate in place of receptacle plate. Attach conduit with wires to blank knockout plate or knockout in side of chassis. Splice to receptacle wires. Reassemble. Installation Options with Mounting Brackets Surface-mount with exposed brackets. Surface-mount with brackets concealed behind unit. Mount to rack rail supports or 10-32 tapped rack rail. Non-metallic flexible whip can be trimmed in the field Snip reinforcing rib at desired length. Bend and carefully cut around conduit without cutting wires inside. Remove excess conduit. Spec. No. 1127 (rev. 06.04.13) pg. 2 of 2 Snip 2 or 3 ribs around the connector and remove connector from excess conduit. Attach connector to shortened conduit length. ©2013 Lowell Manufacturing Company, 100 Integram Dr., Pacific MO 63069. Phone–800.325.9660 Fax—636.257.6606. Lowell makes every effort to provide accurate information while reserving the right to change specifications and/or improve manufacturing methods without notification. (lowellmfg.com)