REVISIONS DESCRIPTION DATE BY HIGH EFFICIENCY LUMINAIRE REQUIREMENTS) ESSION PROF AL R D E A H L E RIC No. C 52489 ER I NE HIGH EFFICIENCY LUMINAIRE REQUIREMENTS) ED NG REGI S TE R STAMP Exp. 12-31-16 S TA WH TE CI V IL A NI R O O F C A LI F HIGH EFFICIENCY LUMINAIRE REQUIREMENTS) BATH 2 UTILITY KITCHEN BEDROOM 4 FAMILY ROOM DINING ROOM A/C SMOKE DETECTOR TYP. LIVING ROOM MASTER BEDROOM BEDROOM 2 CLOSET MASTER BATH BEDROOM 3 CLOSET ELECTRICAL NOTES: 1. SMOKE ALARMS SHALL BE INSTALLER PER CBC 907.2.11.1. 2. BATHROOM AND LAUNDRY FAN SHALL BE CAPABLE OF 5-AIR CHANGES PER HOUR. 3. TELEPHONE OUTLET PREWIRED BY TELEPHONE COMPANY, COORDINATE AS REQUIRED. 4. PROVIDE SWITCHED LIGHT/OUTLET AT ALL ATTIC ACCESSES. 5. ALL 125-VOLT SINGLE PHASE, 15-AND 20 AMPERE RECEPTACLES INSTALLED IN BATHROOMS, GARAGES, OUTDOORS, KITCHENS (COUNTER TOP SURFACES), AND WET BAR SINKS SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL". CEC 210-8(B). 6. PROVIDE A PERMANENT ELECTRICAL RECEPTACLE AND LIGHT FIXTURE SWITCH NEAR THE PASSAGEWAY OPENING, AT OR NEAR THE FURNACE. 7. ALL RECESSED LIGHTS AT INSULATED AREA TO BE IC-RATED. 8. ALL 120-VOLT, SINGLE PHASE, 15-&20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMITY ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. (CEC 210-12). 9. ALL 125-VOLT, 15 AND 20 AMP NON-LOCKING TYPE RECEPTACLES IN THE DWELLING UNITS, GUEST ROOMS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES. (CEC 406.12, 406.13, 406.14) CLOSET FLOOR PLAN W/ ELECTRICAL SCALE: 1/4" = 1'-0" SMOKE ALARM NOTE: MODULAR UNIT 13554 IVIE RD. GALT, CA 95632 A.P.N.: 152-0270-036-000 SMOKE DETECTOR TYP. REQUIRED RESIDENTIAL LIGHTING PER 2013 CALIFORNIA ENERGY CODE: 10. BATHROOM : PERMANTLY INSTALLED LUMINAIRES IN BATHROOM SHALL BE HIGH EFFICACY LUMINAIRES, OR SHALL BE CONTROLLED BY AN MANUAL-ON OCCUPANT SENSOR(S). 11. ALL OTHER INTERIOR ROOMS: PERMANTLY INSTALLED LUMINAIRES SHALL BE HIGH EFFICACY LUMINAIRES, OR SHALL BE CONTROLLED BY A DIMMER SWITCH OR CONTROLLED BY AN MANUAL-ON OCCUPANT SENSOR. 12. OUTDOOR LIGHTING ATTACHED TO BUILDINGS SHALL BE HIGH EFFICACY LUMINAIRES, OR SHALL BE CONTROLLED BY MOTION SENSOR W/ MANUAL-ON / AUTOMATIC OFF SWITCH AND PHOTO CONTROL. 13. TO DETERMINE THE MINIMUM LAMP EFFICACY CATEGORY, ONLY THE WATTS OF THE LAMP (NOT INCLUDING BALLAST) SHALL BE CONSIDERED. A HIGH EFFICACY LAMP HAS A LAMP EFFICACY THAT IS NO LOWER THAN THE EFFICACIES IN THE FOLLOWING TABLE: SHEET TITLE TABLE 150-B MINIMUM REQUIREMENTS FOR OTHER LIGHT SOURCES TO QUALIFY AS HIGH EFFICACY LUMINAIRE POWER RATING MINIMUM LUMINAIRE EFFICACY TO QUALIFY AS HIGH EFFICACY 5 WATTS OR LESS 30 LUMENS PER WATT OVER 5 WATTS TO 15 WATTS 45 LUMENS PER WATT OVER 15 WATTS TO 40 WATTS 60 LUMENS PER WATT OVER 40 WATTS 90 LUMENS PER WATT Note: Determine minimum luminaire efficacy using the system initial rated lumens divided by the luminaire total rated system input power. NOTES: FLOOR PLAN W/ ELECTRICAL NOTES: N.T.S DATE 1. WATER HEATER HAVING NON-RIGID CONNECTORS REQUIRE EARTHQUAKE SUPPORT AS PER 507.2, 2013 CPC. 2. THE UNITS MUST BE SECURED W/ A MINIMUM 1" STRAPS, 22 GA., 2-1/2" LAG SCREWS 1/4"Ø W/ WASHERS ANCHORED INTO THE FRAMING MEMBERS (PERFORATED IRON STRAP IS NOT ALLOWED). 3. STRAPPING SHALL BE AT POINTS WITHIN UPPER ONE-THIRD (1/3) AND LOWER ONE-THIRD (1/3) OF ITS VERTICAL DIMENSIONS. AT THE LOWER POINT, A MINIMUM DISTANCE OF FOUR (4) INCHES SHALL BE MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING PER 2013 CPC 507.2. ALL EXISTING HOUSE DIMENSIONS ARE SHOWN FOR INFORMATION ONLY. ALL DEPENDENT DIMENSIONS ARE TO BE VERIFIED BY THE CONTRACTOR. DRAWN BY CHECKED BY SCALE : SHEET STAIR & LANDING DETAILS