2 floor plan with electrical

advertisement
REVISIONS
DESCRIPTION
DATE
BY
HIGH EFFICIENCY LUMINAIRE REQUIREMENTS)
ESSION
PROF
AL
R
D
E
A
H
L
E
RIC
No. C 52489
ER
I NE
HIGH EFFICIENCY LUMINAIRE REQUIREMENTS)
ED
NG
REGI S
TE
R
STAMP
Exp. 12-31-16
S
TA
WH
TE
CI V IL
A
NI
R
O
O F C A LI F
HIGH EFFICIENCY LUMINAIRE REQUIREMENTS)
BATH 2
UTILITY
KITCHEN
BEDROOM 4
FAMILY ROOM
DINING ROOM
A/C
SMOKE
DETECTOR
TYP.
LIVING ROOM
MASTER BEDROOM
BEDROOM 2
CLOSET
MASTER BATH
BEDROOM 3
CLOSET
ELECTRICAL NOTES:
1. SMOKE ALARMS SHALL BE INSTALLER PER CBC 907.2.11.1.
2. BATHROOM AND LAUNDRY FAN SHALL BE CAPABLE OF 5-AIR CHANGES PER HOUR.
3. TELEPHONE OUTLET PREWIRED BY TELEPHONE COMPANY, COORDINATE AS REQUIRED.
4. PROVIDE SWITCHED LIGHT/OUTLET AT ALL ATTIC ACCESSES.
5. ALL 125-VOLT SINGLE PHASE, 15-AND 20 AMPERE RECEPTACLES INSTALLED IN BATHROOMS,
GARAGES, OUTDOORS, KITCHENS (COUNTER TOP SURFACES), AND WET BAR SINKS SHALL
HAVE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL". CEC 210-8(B).
6. PROVIDE A PERMANENT ELECTRICAL RECEPTACLE AND LIGHT FIXTURE SWITCH NEAR
THE PASSAGEWAY OPENING, AT OR NEAR THE FURNACE.
7. ALL RECESSED LIGHTS AT INSULATED AREA TO BE IC-RATED.
8. ALL 120-VOLT, SINGLE PHASE, 15-&20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED
IN DWELLING UNIT FAMITY ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS,
SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE
PROTECTED BY A LISTED ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO
PROVIDE PROTECTION OF THE BRANCH CIRCUIT. (CEC 210-12).
9. ALL 125-VOLT, 15 AND 20 AMP NON-LOCKING TYPE RECEPTACLES IN THE DWELLING UNITS, GUEST
ROOMS SHALL BE LISTED TAMPER-RESISTANT RECEPTACLES. (CEC 406.12, 406.13, 406.14)
CLOSET
FLOOR PLAN W/ ELECTRICAL
SCALE: 1/4" = 1'-0"
SMOKE ALARM NOTE:
MODULAR UNIT
13554 IVIE RD.
GALT, CA 95632
A.P.N.: 152-0270-036-000
SMOKE
DETECTOR
TYP.
REQUIRED RESIDENTIAL LIGHTING PER 2013 CALIFORNIA ENERGY CODE:
10. BATHROOM : PERMANTLY INSTALLED LUMINAIRES IN BATHROOM SHALL
BE HIGH EFFICACY LUMINAIRES, OR SHALL BE CONTROLLED BY AN
MANUAL-ON OCCUPANT SENSOR(S).
11. ALL OTHER INTERIOR ROOMS: PERMANTLY INSTALLED LUMINAIRES
SHALL BE HIGH EFFICACY LUMINAIRES, OR SHALL BE CONTROLLED BY A
DIMMER SWITCH OR CONTROLLED BY AN MANUAL-ON OCCUPANT
SENSOR.
12. OUTDOOR LIGHTING ATTACHED TO BUILDINGS SHALL BE HIGH
EFFICACY LUMINAIRES, OR SHALL BE CONTROLLED BY MOTION SENSOR
W/ MANUAL-ON / AUTOMATIC OFF SWITCH AND PHOTO CONTROL.
13. TO DETERMINE THE MINIMUM LAMP EFFICACY CATEGORY, ONLY THE
WATTS OF THE LAMP (NOT INCLUDING BALLAST) SHALL BE CONSIDERED.
A HIGH EFFICACY LAMP HAS A LAMP EFFICACY THAT IS NO LOWER THAN
THE EFFICACIES IN THE FOLLOWING TABLE:
SHEET TITLE
TABLE 150-B
MINIMUM REQUIREMENTS FOR OTHER LIGHT
SOURCES TO QUALIFY AS HIGH EFFICACY
LUMINAIRE POWER
RATING
MINIMUM LUMINAIRE
EFFICACY TO QUALIFY
AS HIGH EFFICACY
5 WATTS OR LESS
30 LUMENS PER WATT
OVER 5 WATTS TO 15 WATTS
45 LUMENS PER WATT
OVER 15 WATTS TO 40 WATTS
60 LUMENS PER WATT
OVER 40 WATTS
90 LUMENS PER WATT
Note: Determine minimum luminaire efficacy using the system initial rated
lumens divided by the luminaire total rated system input power.
NOTES:
FLOOR PLAN
W/
ELECTRICAL
NOTES:
N.T.S
DATE
1. WATER HEATER HAVING NON-RIGID CONNECTORS REQUIRE
EARTHQUAKE SUPPORT AS PER 507.2, 2013 CPC.
2. THE UNITS MUST BE SECURED W/ A MINIMUM 1" STRAPS, 22 GA.,
2-1/2" LAG SCREWS 1/4"Ø W/ WASHERS ANCHORED INTO THE
FRAMING MEMBERS (PERFORATED IRON STRAP IS NOT ALLOWED).
3. STRAPPING SHALL BE AT POINTS WITHIN UPPER ONE-THIRD (1/3)
AND LOWER ONE-THIRD (1/3) OF ITS VERTICAL DIMENSIONS. AT THE
LOWER POINT, A MINIMUM DISTANCE OF FOUR (4) INCHES SHALL
BE MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING PER
2013 CPC 507.2.
ALL EXISTING HOUSE DIMENSIONS ARE SHOWN FOR INFORMATION ONLY. ALL
DEPENDENT DIMENSIONS ARE TO BE VERIFIED BY THE CONTRACTOR.
DRAWN BY
CHECKED BY
SCALE :
SHEET
STAIR & LANDING DETAILS