Edge Device Quick Start Guide With Brivo ACS Plug-In for Brivo OnAir® and Brivo Aparato® 10/28/2014 Legal Disclaimers 65B Canada-Underwriters Laboratories (C-UL) Compliancy For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian Electrical Code. 66B Documentation Disclaimer and Restrictions Information in this document is subject to change without notice and does not represent a commitment on the part of Brivo Systems, LLC. For the most up-to-date information, visit www.brivo.com . HU UH This document and the data herein shall not be duplicated, used or disclosed to others for procurement or manufacturing, except as authorized with the written permission of Brivo Systems, LLC. The information contained within this document or within the product itself is considered the exclusive property of Brivo Systems, LLC. All information in this document or within the hardware and software product themselves is protected by the copyright and/or other intellectual property laws of the United States. © 2014 Brivo Systems, LLC. All rights reserved. Brivo® is a registered trademark of Brivo Systems, LLC. Brivo Systems, LLC, 7700 Old Georgetown Road, Suite 300, Bethesda, MD 20814. Quick Start Guide 3 Table of Contents Introduction ........................................................................................................................ 4 Parts List ......................................................................................................................... 4 Product Specifications ................................................................................................... 4 Cable Specifications ...................................................................................................... 4 Overview ............................................................................................................................. 5 Step One: Connect ......................................................................................................... 5 Step Two: Communicate ................................................................................................ 5 Step One: Connect ............................................................................................................. 6 Wiring the Edge Device .................................................................................................. 6 Step Two: Communicate .................................................................................................... 7 Manually Connecting to an Edge Device .......................................................................... 8 For Brivo OnAir: .............................................................................................................. 8 For Aprato: ...................................................................................................................... 8 Appendices ....................................................................................................................... 10 Network Defaults Jumper ............................................................................................ 10 Contact Information ......................................................................................................... 11 Worksheet ........................................................................................................................ 12 For OnAir: ...................................................................................................................... 12 For Aparato: .................................................................................................................. 12 © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014 Quick Start Guide 4 Introduction The HID EdgeReader™ and EdgePlus™ with the Brivo ACS Plug-In provide a control processor that is wired to connect automatically to Brivo’s web interface. Parts List Description EdgeReader or EdgePlus Mounting screws 2.2K EOL resistors Quick Installation Guide Quantity 1 4 8 1 Product Specifications Description Power Supply Maximum current at 12 VDC Average operating current at 12 VDC Maximum Supplied Power —ERW400 EdgeReader —E400 EdgePlus Relay Contact Rating Operating temperature range Humidity Specification 12-16 VDC or Power over Ethernet (PoE) 1 Amp 300 mA—EdgeReader and no accessories 600 mA—Split between one or two relays 700 mA—Split between a reader and one or two relays 2 Amps at 30 VDC 32˚- 122˚F (0˚- 50˚ C) 5% to 95% non-condensing Cable Specifications Cable Input Circuits* Length 500 feet (150 m) Specification 2-conductor, shielded, using ALPHA 1292C (22AWG) or Alpha 2421C (18AWG), or equivalent. Output Circuits* 500 feet (150 m) 2-conductor, using ALPHA 1172C (22AWG) or Alpha 1897C (18AWG), or equivalent. Wiegand (Remote mounted 500 feet (150 m) to ALPHA 1299C, 22AWG, 9-conductor, reader only) reader stranded, overall shield. Fewer conductors needed if all control lines are not used. Ethernet 328 feet (100 m) Cat5, Cat5E, and Cat6 Power Supply + 12 VDC IN ---Refer to your Power Supply Installation Guide *Minimum wire gauge is dependent upon cable length and current requirements. © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014 Quick Start Guide 5 Overview The following outline provides a brief explanation of the required steps for installing the Edge device. Step One: Connect Mount and wire the Edge device. Step Two: Communicate The Edge device automatically communicates with Brivo Central, provided the network supports DHCP, to complete data configuration. © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014 Quick Start Guide 6 Step One: Connect Wiring the Edge Device 1. Preparation Install electrical box. For new installations: use a 4” square electrical box (minimum of 1 ½” deep) with a single-gang plaster ring. To prevent tampering: Conceal plaster ring mounting screws with drywall or use tamper resistant screws. For surface-mount installations: use Wiremold® V5744S or BW35. Remove metal back-plate from unit and mount to electrical box, as shown. © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014 Quick Start Guide 7 2. Wiring Follow the diagram below for wiring assistance. 3. Mount Position the Edge device and mount with a screw. Step Two: Communicate The device will automatically configure itself if the network supports DHCP. If this is not the case, connect the device to a laptop and login manually to the Configuration GUI to set the networking parameters manually. If you still encounter problems, please see the Network Setup guide. © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014 Quick Start Guide 8 Manually Connecting to an Edge Device This section explains how to connect a laptop to access the diagnostic interface for the Edge device if the device does not automatically connect, or if the network does not support DHCP and manual network setup is required. The device must have a known IP address if it is to be accessed from other machines on the network. The most convenient way to achieve this is to set a Static IP Address appropriate for the local network. Contact your LAN administrator for the corresponding settings. For Brivo OnAir: To set static parameters or proxy settings: 1. Connect Edge device to laptop. 2. Open your browser and enter the address http://169.254.242.121. 3. The login page will display, prompting for login information. The default username is “admin.” Leave the password field blank. 4. The password page displays. Choose a username and enter password. Click “set password.” A page displays to signify that the changes have been saved successfully o To set static IP address: 1. Click on the Networking tab. a. Click IP Configuration. b. Click the “Deactivate DHCP” button. c. Fill in the fields according to the worksheet at the end of this document. d. Click Set Static Parameters. Changes have been saved. o To set proxy server settings: 1. Click on the Networking tab. a. Click Proxy Server. b. Fill out the fields according to the worksheet. If SOCKS5 proxy server settings are required, fill in: i. Address ii. Port iii. Username iv. Password c. Click Accept. Changes have been saved. After settings are configured, reconnect the Ethernet cable back into the main network and check to ensure that the device is communicating with Brivo Central. For Aprato: To set static parameters: 1. Connect the Edge device to your laptop. 2. Open your browser and enter the address http://169.254.242.121. 3. The login page will display, prompting for login information. The default username is “admin.” Leave the password field blank. © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014 Quick Start Guide 9 4. The password page displays. Choose a username and enter a password. Click “set password.” A page displays to signify that the changes have been saved successfully o To set static IP address (FOR TEMPORARY SET UP ONLY): 1. Click on the Networking tab. a. Click IP Configuration. b. Click the “Deactivate DHCP” button. c. Fill in the fields according to the worksheet at the end of this document. d. Click Set Static Parameters. Changes have been saved. 2. Reconnect both the Edge device and the laptop to the main network. 3. Go to http://<edgeIP>/cgi-bin/server.cgi and enter the SE appliance’s IP address. Software for the Edge device installs. NOTE: When you click submit, a page will display that may or may not give updates about the device’s status. Allow the page to run to completion before powering down the device. o If necessary, return network to DHCP configuration: 1. Enter into the address field of your browser http://169.254.242.121. 2. The login page displays. Enter login information. 3. Click Networking tab. 4. Click IP Address Configuration. Click the “Activate DHCP” button. To verify connectivity: 1. Login to the SE appliance. 2. The Dashboard page display. 3. Click Hardware Status. 4. The page will display the control panel number of the Edge device on the list of control panels with the corresponding IP address, signifying that the device is communicating with the SE appliance. . © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014 Quick Start Guide 10 Appendices Network Defaults Jumper Use the Network Defaults Jumper to correct possible errors in the network configuration of an Edge device in order to proceed normally with configuration or reconfiguration. WARNING: All network configuration information will be overwritten upon rebooting the Edge device with a jumper in place. To use the Network Defaults Jumper: 1. Remove the jumper from the Tamper header. 2. Place the same jumper over the two left pins of the P65 header as shown in the figure above. 3. Reboot the Edge device to change all of the configuration settings back to the factory default settings. 4. After the LED turns amber, remove the jumper from the P65 header and return it to the Tamper header. The Edge device will take approximately 60 seconds to reset following the removal of the jumper. Once the device finishes rebooting, the LED will blink green. 5. Configure the Edge device for your installation parameters. © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014 Quick Start Guide 11 Contact Information Brivo Systems, LLC. 7700 Old Georgetown Road Suite 300 Bethesda, MD 20814 Brivo Technical Support: (866) 274-8648, or: customercare@brivo.com Toll-free Brivo Sales: (866) 692-7486 or: sales@brivo.com Main: (301) 664-5242 Fax Number: (301) 664-5264 www.brivo.com © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014 Quick Start Guide 12 Worksheet For OnAir: Static IP Settings o IP Address: _______________________________________________ o Netmask: _______________________________________________ o Gateway: _______________________________________________ o Primary DNS: _______________________________________________ o Secondary DNS: _______________________________________________ o Tertiary DNS: _______________________________________________ SOCKS5 Proxy Server: o Address: _______________________________________________ o Port: _______________________________________________ o Username: _______________________________________________ o Password: _______________________________________________ For Aparato: Static IP Settings o IP Address: _______________________________________________ o Netmask: _______________________________________________ o Gateway: _______________________________________________ o Primary DNS: _______________________________________________ o Secondary DNS: _______________________________________________ o Tertiary DNS: _______________________________________________ Aparato IP address: _______________________________________________ © 2014 Brivo Systems, LLC. All rights reserved. 10/28/2014