Edge Device Quick Start Guide With Brivo ACS Plug

advertisement
Edge Device Quick Start Guide
With Brivo ACS Plug-In for
Brivo OnAir® and Brivo OnSite Server
10/28/2014
Legal Disclaimers
65B
Canada-Underwriters Laboratories (C-UL) Compliancy
For C-UL Listed applications, the unit shall be installed in accordance with Part 1 of the Canadian
Electrical Code.
66B
Documentation Disclaimer and Restrictions
Information in this document is subject to change without notice and does not represent a
commitment on the part of Brivo Inc. For the most up-to-date information, visit www.brivo.com .
HU
UH
This document and the data herein shall not be duplicated, used or disclosed to others for
procurement or manufacturing, except as authorized with the written permission of Brivo Inc. The
information contained within this document or within the product itself is considered the exclusive
property of Brivo Inc. All information in this document or within the hardware and software product
themselves is protected by the copyright and/or other intellectual property laws of the United States.
© 2015 Brivo Inc. All rights reserved.
Brivo® is a registered trademark of Brivo, Inc. Brivo, Inc., 7700 Old Georgetown Road, Suite 300,
Bethesda, MD 20814.
Quick Start Guide
3
Table of Contents
Introduction ........................................................................................................................ 4
Parts List ......................................................................................................................... 4
Product Specifications ................................................................................................... 4
Cable Specifications ...................................................................................................... 4
Overview ............................................................................................................................. 5
Step One: Connect ......................................................................................................... 5
Step Two: Communicate ................................................................................................ 5
Step One: Connect ............................................................................................................. 6
Wiring the Edge Device .................................................................................................. 6
Step Two: Communicate .................................................................................................... 7
Manually Connecting to an Edge Device .......................................................................... 8
For Brivo OnAir: .............................................................................................................. 8
For Brivo OnSite Server: ................................................................................................ 8
Appendices ....................................................................................................................... 10
Network Defaults Jumper ............................................................................................ 10
Contact Information ......................................................................................................... 11
Worksheet ........................................................................................................................ 12
For OnAir: ...................................................................................................................... 12
For Brivo OnSite Server: .............................................................................................. 12
© 2015 Brivo, Inc. All rights reserved.
10/28/2014
Quick Start Guide
4
Introduction
The HID EdgeReader™ and EdgePlus™ with the Brivo ACS Plug-In provide a control processor
that is wired to connect automatically to Brivo’s web interface.
Parts List
Description
EdgeReader or EdgePlus
Mounting screws
2.2K EOL resistors
Quick Installation Guide
Quantity
1
4
8
1
Product Specifications
Description
Power Supply
Maximum current at 12 VDC
Average operating current at 12 VDC
Maximum Supplied Power
—ERW400 EdgeReader
—E400 EdgePlus
Relay Contact Rating
Operating temperature range
Humidity
Specification
12-16 VDC or Power over Ethernet (PoE)
1 Amp
300 mA—EdgeReader and no accessories
600 mA—Split between one or two relays
700 mA—Split between a reader and one
or two relays
2 Amps at 30 VDC
32˚- 122˚F (0˚- 50˚ C)
5% to 95% non-condensing
Cable Specifications
Cable
Input Circuits*
Length
500 feet (150 m)
Specification
2-conductor, shielded, using ALPHA 1292C
(22AWG) or Alpha 2421C (18AWG), or
equivalent.
Output Circuits*
500 feet (150 m)
2-conductor, using ALPHA 1172C (22AWG)
or Alpha 1897C (18AWG), or equivalent.
Wiegand (Remote mounted
500 feet (150 m) to
ALPHA 1299C, 22AWG, 9-conductor,
reader only)
reader
stranded, overall shield. Fewer conductors
needed if all control lines are not used.
Ethernet
328 feet (100 m)
Cat5, Cat5E, and Cat6
Power Supply + 12 VDC IN
---Refer to your Power Supply Installation
Guide
*Minimum wire gauge is dependent upon cable length and current requirements.
© 2015 Brivo, Inc. All rights reserved.
10/28/2014
Quick Start Guide
5
Overview
The following outline provides a brief explanation of the required steps for installing the Edge
device.
Step One: Connect
Mount and wire the Edge device.
Step Two: Communicate
The Edge device automatically communicates with Brivo Central, provided the network
supports DHCP, to complete data configuration.
© 2015 Brivo, Inc. All rights reserved.
10/28/2014
Quick Start Guide
6
Step One: Connect
Wiring the Edge Device
1. Preparation
Install electrical box.
For new installations: use a 4” square electrical box (minimum of 1 ½” deep)
with a single-gang plaster ring.
To prevent tampering: Conceal plaster ring mounting screws with drywall or use
tamper resistant screws.
For surface-mount installations: use Wiremold® V5744S or BW35.
Remove metal back-plate from unit and mount to electrical box, as shown.
© 2015 Brivo, Inc. All rights reserved.
10/28/2014
Quick Start Guide
7
2. Wiring
Follow the diagram below for wiring assistance.
3. Mount
Position the Edge device and mount with a screw.
Step Two: Communicate
The device will automatically configure itself if the network supports DHCP. If this is not the
case, connect the device to a laptop and login manually to the Configuration GUI to set the
networking parameters manually. If you still encounter problems, please see the Network
Setup guide.
© 2015 Brivo, Inc. All rights reserved.
10/28/2014
Quick Start Guide
8
Manually Connecting to an Edge Device
This section explains how to connect a laptop to access the diagnostic interface for the Edge
device if the device does not automatically connect, or if the network does not support DHCP
and manual network setup is required.
The device must have a known IP address if it is to be accessed from other machines on the
network. The most convenient way to achieve this is to set a Static IP Address appropriate for
the local network. Contact your LAN administrator for the corresponding settings.
For Brivo OnAir:
§
To set static parameters or proxy settings:
1. Connect Edge device to laptop.
2. Open your browser and enter the address http://169.254.242.121.
3. The login page will display, prompting for login information. The default
username is “admin.” Leave the password field blank.
4. The password page displays. Choose a username and enter password. Click
“set password.” A page displays to signify that the changes have been saved
successfully
o
To set static IP address:
1. Click on the Networking tab.
a. Click IP Configuration.
b. Click the “Deactivate DHCP” button.
c. Fill in the fields according to the worksheet at the end of
this document.
d. Click Set Static Parameters. Changes have been saved.
o
To set proxy server settings:
1. Click on the Networking tab.
a. Click Proxy Server.
b. Fill out the fields according to the worksheet. If SOCKS5
proxy server settings are required, fill in:
i. Address
ii. Port
iii. Username
iv. Password
c. Click Accept. Changes have been saved.
After settings are configured, reconnect the Ethernet cable back into the main
network and check to ensure that the device is communicating with Brivo Central.
For Brivo OnSite Server:
§
To set static parameters:
1. Connect the Edge device to your laptop.
2. Open your browser and enter the address http://169.254.242.121.
3. The login page will display, prompting for login information. The default
username is “admin.” Leave the password field blank.
© 2015 Brivo, Inc. All rights reserved.
10/28/2014
Quick Start Guide
9
4. The password page displays. Choose a username and enter a password.
Click “set password.” A page displays to signify that the changes have been
saved successfully
o
To set static IP address (FOR TEMPORARY SET UP ONLY):
1. Click on the Networking tab.
a. Click IP Configuration.
b. Click the “Deactivate DHCP” button.
c. Fill in the fields according to the worksheet at the end of
this document.
d. Click Set Static Parameters. Changes have been saved.
2. Reconnect both the Edge device and the laptop to the main
network.
3. Go to http://<edgeIP>/cgi-bin/server.cgi and enter the SE
appliance’s IP address. Software for the Edge device installs.
NOTE: When you click submit, a page will display that may or may not give
updates about the device’s status. Allow the page to run to completion before
powering down the device.
o
§
If necessary, return network to DHCP configuration:
1. Enter into the address field of your browser
http://169.254.242.121.
2. The login page displays. Enter login information.
3. Click Networking tab.
4. Click IP Address Configuration. Click the “Activate DHCP” button.
To verify connectivity:
1. Login to the SE appliance.
2. The Dashboard page display.
3. Click Hardware Status.
4. The page will display the control panel number of the Edge device on the list
of control panels with the corresponding IP address, signifying that the
device is communicating with the SE appliance.
.
© 2015 Brivo, Inc. All rights reserved.
10/28/2014
Quick Start Guide
10
Appendices
Network Defaults Jumper
Use the Network Defaults Jumper to correct possible errors in the network configuration of an
Edge device in order to proceed normally with configuration or reconfiguration.
WARNING: All network configuration information will be overwritten upon
rebooting the Edge device with a jumper in place.
• To use the Network Defaults Jumper:
1. Remove the jumper from the Tamper header.
2. Place the same jumper over the two left pins of the P65 header as shown in
the figure above.
3. Reboot the Edge device to change all of the configuration settings back to
the factory default settings.
4. After the LED turns amber, remove the jumper from the P65 header and
return it to the Tamper header. The Edge device will take approximately 60
seconds to reset following the removal of the jumper. Once the device
finishes rebooting, the LED will blink green.
5. Configure the Edge device for your installation parameters.
© 2015 Brivo, Inc. All rights reserved.
10/28/2014
Quick Start Guide
11
Contact Information
Brivo Inc.
7700 Old Georgetown Road
Suite 300
Bethesda, MD 20814
Brivo Technical Support: (866) 274-8648, or: customercare@brivo.com
Toll-free Brivo Sales: (866) 692-7486 or: sales@brivo.com
Main: (301) 664-5242
Fax Number: (301) 664-5264
www.brivo.com
© 2015 Brivo, Inc. All rights reserved.
10/28/2014
Quick Start Guide
12
Worksheet
For OnAir:
•
•
Static IP Settings
o
IP Address:
_______________________________________
o
Netmask:
_______________________________________
o
Gateway:
_______________________________________
o
Primary DNS:
_______________________________________
o
Secondary DNS:
_______________________________________
o
Tertiary DNS:
_______________________________________
SOCKS5 Proxy Server:
o
Address:
_______________________________________
o
Port:
_______________________________________
o
Username:
_______________________________________
o
Password:
_______________________________________
For Brivo OnSite Server:
•
•
Static IP Settings
o
IP Address:
_______________________________________
o
Netmask:
_______________________________________
o
Gateway:
_______________________________________
o
Primary DNS:
_______________________________________
o
Secondary DNS:
_______________________________________
o
Tertiary DNS:
_______________________________________
Brivo OnSite Server IP address:
_______________________________________
© 2015 Brivo, Inc. All rights reserved.