PROTECTION • SERVICE • SAVINGS H.J. Arnett Leads by Example with Superior Standards and Excellent Service SALES TESTING BEYOND Industry Standards • Personal Protection Equipment • Energy Theft Investigation Tools • Service Conductor Testers • FR & Arc Flash Equipment • Underground Fault Locators • Hotline Tools • Insulated Tools • Grounds and Insulated Jumpers TEST • Gloves • Boomtrucks • Blankets • Hotline Tools • Plastic Cover-ups • On Site Field Testing • New or Faulted Cables • Hot Jumper and Ground Cables RENEW •Refurbish existing tools to maintain safety standards and save money. Arc Flash Clothing, Arc Suppression Blankets, Barriers, Canvas or Vinyl Storage Bags, Cover-ups, Eye Protection, Face Shields, Fault Locators, FR Clothing, Ground Cables, Hard Covers, Hard Hats, High and Low Voltage Rubber Blankets, High and Low Voltage Rubber Gloves, High Voltage Rubber Hoods, Hot Jumper Cables, Hot Line Tools and Accessories, Indura Flame Resistant Clothing, Industrial Flash Lights, Insulated Tools, Insulated Rubber Matting, Labels (Safety, Warning, etc.), Line Hose, Nomex Suits, Phasing Testers, Protera Fire Resistant Clothing, Rubber Protective Sleeves, Safety Vests (Hi-Vis & FR), Service Conductor Testers, Switchboard Matting, Voltage Detectors, Wire Strippers & more! You Asked and We Responded! Constant changes to your company’s work environment, work practices and regulations make the need to react immediately a must. Arnett Industries has expanded our product offerings to become your trusted source for safety tools and equipment for utility construction, maintenance, and repair. If we don’t have what you’re looking for, we will find the best contact for you to follow up with. See our new offerings: • Personal Protective Equipment & Clothing • Hi-Vis and FR Clothing (4 cal/cm2 to 100 cal/cm2) • 1000 Volt Insulated Tools • Voltage Detectors • Hot-Line Tools, Arms, Gins • Custom Ground and Bypass Jumper Cables • Outage Protection • Insulating Rubber Gloves, Blankets, Sleeves, Matting and Over Shoes • Line Hoses, Hoods & Plastic Cover-ups Call Us to Setup: Product Demonstrations or Employee Wear Trial Testing NEW DISTRIBUTION & TOOL MAINTENANCE Table I-6 from OSHA 1910.137 Rubber Insulating Equipment Test Intervals Utility worker safety is our MAIN CONCERN! We may test rubber gloves, but it doesn’t stop there... Do you know about our other testing services? • Hot-Line Tool Testing and Refurbishing • Hot Arm, Bypass Jumper or Ground Cluster Testing • Boom Truck Hi-Voltage Test • Equipment Cover-up Dielectric Testing • New Cable Reel Acceptance Test & Faulted Cable Analysis Type Of Equipment When To Test Rubber insulating LINE HOSE Upon indication that insulating value is suspect. Rubber insulating COVERS Upon indication that insulating value is suspect. Rubber insulating BLANKETS Before first issue and every 12 months thereafter (1). Rubber insulating GLOVES Before first issue and every 6 months thereafter(1). Rubber insulating SLEEVES Before first issue and every 12 months thereafter(1). Footnote(1) If the insulating equipment has been electrically tested but not issued for service, it may not be placed into service unless it has been electrically tested within the previous 12 months. In Oregon, the testing intervals for rubber insulating gloves and sleeves is every 3 months. See OAR 437-002-0138. Additional Oregon rule for Electrical Protective Equipment Call Us to Setup: Onsite or In-House Recertification Testing Program (1) Test of Rubber Gloves and Sleeves. Rubber gloves and sleeves shall be electrically tested at least once every 3 months after they are checked out for use, and complete records shall be kept of all such tests and date of issue. Rubber gloves and sleeves not checked out for use within 6 months shall be retested before being issued.