"C" Dim. Aprx. Wt. (lb) Full Load Efficiency Voltage 1800 143T ECP3581T-5 1800 145T ECP3584T-5 1800 145T ECP3587T-5 1800 182T ECP3661T-5 3 1200 213T ECP3764T-5 1800 184T ECP3665T-5 5 1200 215T Alternatives ECP3768T-5 Functionally Equivalent $798 812 848 1,073 1,508 1,093 1,528 L1 L1 L1 L1 L1 L1 L1 12.88 12.88 12.88 15.93 19.32 15.93 19.32 60 65 68 103 186 121 205 86.5 86.5 86.5 89.5 89.5 90.2 89.5 575 575 575 575 575 575 575 1 1 1/2 2 Full Load Notes (a) Amps 1.1 1.6 2.2 3.2 4 5.2 6.4 1 1 1 1 1 1 1 Reliance M/N P14G7545 P14G7548 P14G7550 P18G3373 P21G3353 P18G3374 P21G3354 Catalog Numbers shown with an indented Reliance M/N immediately below identify functionally equivalent products. Both numbers will be stocked. While these motors have the same mounting dimensions and similar performance, there may be some slight differences such as “C” dimension, weight, amps, etc. If one motor is not available, consider the functionally equivalent as an alternative. Hp RPM NEMA Frame 56C 56C 1/4 56C 1200 56C 3600 56C 56C 1/3 1800 56C 501 Catalog Notes 56C 1800 Catalog Number CNM3454/35 ➥P56X3166 P56H3615 CNM3531 CNM3457 ➥P56X1523 CM3534 ➥P56H3119 List Price Mult. Sym. “C” Dim. Aprx. Wt. (lb) Full Load Efficiency Voltage Full Load Amps $404 404 404 513 296 424 293 293 K K K K K K LS LS 10.44 11.07 10.25 11.07 11.07 11.07 11.35 10.25 28 28 21 31 31 31 22 24 68 80 68 68 80 80 68 70 208-230/460 230/460 208-230/460-480 230/460 230/460 230/460 230/460 208-230/460 0.4 0.4 0.55 0.7 0.6 0.6 0.8 0.7 Notes (a) 15 15 30 30 30 15 • Most steel band and cast iron foot-mounted motors have dual mounting holes (143T-145T, 182T-184T, etc.). Cast iron Athens-built 447 and 449 frame motors in M, ECP and ECP841 product families have single foot mounting holes. • All cast iron motors are built with symmetrical frames which may be converted from F1 to F2 by switching endplates and rotor from end-to-end except for L182T, L184T, L213T, L215T and L449T. Frames with the “L” prefix have standard NEMA base and BA dimensions. Also applies to TC versions of these frame sizes. • ECP, ECP841 and ECP641 motors are now painted with the Reliance blue-green color epoxy paint instead of the grey epoxy. Authorized Service Centers and Service Policy — Refer to Baldor's website (www.baldor.com) for a complete listing of service centers and our service/repair policy Dimensions — Refer to Baldor's website: (www.baldor.com) for dimensions for all stock AC and DC motor ratings. Efficiencies — All efficiencies listed are nominal efficiencies at full load. General Information Single Phase Motors Mult. Sym. General Purpose Industrial Motors NEMA Frame Premium Efficient Super-E® Motors List Price RPM Severe Duty Motors Catalog Number Hp Washdown Duty Motors Understanding 501 Catalog Numbers Conversions to Single Design Motors shown with a Catalog Number and a Reliance M/N on the same line indicate that these motors have been converted to one design. The Reliance M/N is provided as a reference to help determine the current catalog number to order by. Products that follow this format will include CP, ECP, CECP, VECP and other servere duty / chemical processing, washdown duty and single phase stock motors. Explosion Proof Motors General Information Renewal Parts and Installation – Maintenance Data — A parts list for each motor is shown online at www.baldor.com. Data Section 506 contains a wide variety of the most commonly required service parts. AC (MN400) and DC (MN605) motor installation and maintenance data are also available. SCR Drive Motors — Field Amps listed are for High Voltage Connections with motor at operating temperature. Service Factor — NEMA T-frames in TEFC construction have a service factor of 1.15 or greater except where noted. All NEMA U- frame TEFC motors (except explosion-proof) have NEMA open service factors. Fractional horsepower TEFC motors have NEMA open service factors. All DC motors have 1.0 service factors. Freight Policy — Shipments of stock products shown in this catalog are made with the selling terms of F.O.B. factory or warehouse. International Shipments - Ex Works, Non-stock items - FOB Factory. Baldor will prepay and absorb freight charges, on a carrier chosen by Baldor, to the first destination in the continental United States on shipments of 1500 pounds (1000 pounds on portable generators) or more. Contact your local Baldor•Reliance District office for clarification, assistance or additional information on any Baldor•Reliance product. A listing of the offices is on page 575. Commercial Motors Performance and connection diagrams — Baldor's website (www.baldor.com) lists performance test data and connection diagrams for all stock AC and DC motor ratings. HVAC Motors Modified Motors — Details of Baldor’s Mod Express Program are listed in this catalog. Using stock motors, Baldor can modify motors to fit a variety of applications in only 2 to 5 working days for most modifications. Pump Motors Full Load Amps – FLA — For low voltage amps, double high voltage amps shown. ­ General Information General Information Abbreviations: The Basic Baldor catalog number consists of a letter(s) prefix and several non-significant proceeding numbers. A suffix letter(s) and/or number(s) may also be part of the catalog number. For example L3510 or L3510T. Following is a list of prefix and suffix definitions. Catalog Number Prefix: Single Phase Motors General Purpose Industrial Motors Premium Efficient Super-E® Motors Severe Duty Motors Washdown Duty Motors Explosion Proof Motors Pump Motors Commercial Motors HVAC Motors ­ AEM AF AM ANF AO AP AS B BC BK BLW BMC BSM BTG BU C CBL CD CDP CDPT CDPWD CDPSWD CDPX CDX CESWDM CF CHC CP CR CSC CSM CSSEWDM CSSWDM CSWDM CWAM CWDSM D DE DG DMG DOC DR E E3H ECP EN FM FCD FD FFC FL G GC GCP GD GF GP GPP Automotive Motor (GM7EHQ) Aeration Fan Motor Automotive (Motor GM7EQ) Auger Flange Motor Air-Over Motor Subfractional HP, PM Motor Arbor Saw Motor Brake Motor DC Motor Speed Control Single Phase Gearmotor Kit Blower Kit Brushless DC Motor Control Brushless Servo Motors Tachometer Generator Bushing Kit NEMA C-Face with Base Cable Assembly Wound Field DC Motor NEMA C-Face with Base PM SCR Drive Motor PM SCR Drive Motor with Integral Tachometer Washdown PM SCR Drive Motor, NEMA C-Face PM Paint Free Washdown SCR Drive Motor C-Face with base PM Explosion Proof SCR Drive Motor C-Face with base Wound Field Explosion Proof DC Motor, NEMA C-Face Paint Free Super-E Washdown - C-Face with base Condenser Fan Motor Direct Drive Fan Motor with Resilient Base Chemical Processing, Corrosion Protected Motor Crusher Motor Checkout Stand Motor Baldor SmartMotor All Stainless Super-E Washdown-C-Face with base All Stainless Washdown - C-Face with base Paint Free Washdown - C-Face with base Dirty Duty Washdown - C-Face with base Baldor Washdown SmartMotor DC Shunt or Compound Motor or Definite Purpose Soft Start Control Vacuum Pump Motor Gate Operator Motor Lifting Magnet Generator Door Operator Motor Double Reduction Super-E Premium Efficiency Super-E Premium Efficiency HVAC Duty with Connection Box located on top of Motor Super-E Premium Efficiency, Chemical Processing Hostile Environment Motor Encoder Kit F-2 Mount Motor Drip Cover Kit Farm Duty Motor Fan Cover/Conduit Box Kit Flange Kit Subfractional HP Gear Motor Permanent Split Capacitor and Split Phase Permanent Split Capacitor and Split Phase Parallel Shaft Gearmotor Centrifugal Fan Motor 900 Series Reducers Subfractional HP PM Motor PM Parallel Shaft Gear Motor GSF GS H H3 HP ID IDM IDNM IDWNM IDXM IM IR J JM JP JSL K KN L LRA M M MM MPM MVM N OF P P15 PSC R RBT RES RG RH RL&RM RT S SD SS SWD T TA TM TK UC V VH VJM VLCP VP VPCP WC WD WW ZD ZDM ZDNM ZDWNM Universal Series Right Angle Gear Reducers Grain Stirring Motor Definite Purpose HVAC Motors HVAC Duty with Connection Box located on top of Motor Hydraulic Pump Motor Inverter Control Inverter Drive Motor-TEBC Inverter Drive Motor-TENV Washdown Inverter Motors-TENV Explosion proof Inverter Drive Motors-TEFC Irrigation Drive Motor Instant Reversing Single Phase Farm Motor NEMA 56J Stainless Steel Threaded Shaft with Dripcover NEMA JM Pump shaft & Face with Base NEMA JP Pump shaft & Face with Base Square Flange Pump Motors with threaded shaft. Model 34 Diameter Motor with 56 C-Face, less Base Model 34 Diameter TENV Motor with 56 C-Face, less Base Single Phase Line Reactor Three Phase Multipurpose Soft Start Control Metric Dimension Motor with Base Three Phase Metering Pump Metric Dimension Motor, Flange Mount less Base Totally Enclosed Non ventilated Design D, High Slip Motor (Oil Field) Pressure Washer Motor Pre-Engineered Control Panel Permanent Split Capacitor Repulsion-Start, Induction-Run Motor Roller Bearing Conversion Kit Resolver Feedback Kit Regeneration Resistor Assembly Definite Purpose HVAC Motors Resilient Base(Cradle Mount) Dynamic Braking Resistor Assembly Single Phase Soft Start Series 23H Servo Control All Stainless Washdown Duty Stainless Washdown Duty Torque Control Torque Arm Definite Purpose HVAC Motors with Terminal Panel Endplate Tachometer Mounting Kit Universal Crop Dryer Motor NEMA C-Face less Base Vertical Pump Motor, Normal Thrust NEMA JM Pump Shaft and Face less Base Vertical Pump Motor, Medium Thrust PM SCR Drive Motor with Metric Face or Flange Vertical Pump Motor, High Thrust West Coast Fit NEMA TCZ Washdown Duty Woodworking Motor Vector Control Vector Drive Motor-TEBC Vector Drive Motor-TENV Washdown Vector Motors-TENV Catalog Number Suffix: -2 120/240V Field -277 277 Volt Winding -4 460 Volt Winding -5 575 Volt Winding -8 200 Volt Winding -9 NEMA Design C High Torque Winding -12 12 Leads /35 Full 140 Frame Band Diameter /36 Full 180 Frame Band Diameter -50 Wound for 50 Hertz Service -2341 2300/4160 Volt Winding A Automatic Thermal Overload BV Blower Vented -C Listing includes Class I, Group C -CL Open Chassis Enclosure, Line Regenerative -CO Open Chassis Enclosure, no internal braking E Electric Switch -E NEMA 1 Enclosure, built in Dynamic Braking -EL NEMA 1 Enclosure, Line Regenerative -EO NEMA 1 Enclosure, no internal braking -ER NEMA 1 Enclosure, built in Dynamic Braking Transistor -I Explosion-Proof, 1.15 Service Factor M Manual Thermal Overload -MO Protected Chassis Enclosure, no internal braking P Wound Field DC Motor NEMA “AT” Frame -P Partial AC Motor Excludes R- Roller Bearing T NEMA "T" Frame Dimension TP Feather Picker Motor TR NEMA “T” Frame-Roller Bearing TS NEMA "TS" Frame Short Shaft Pulley Endplate -V12 12 Volt DC -V24 24 Volt DC -W NEMA 4 Enclosure -WR Washdown Rating Gear Reducer Suffix: 900 Series A 56C Motor Flange B 140TC Motor Flange C 180TC Motor Flange G Left Hand Output Shaft H Double End Output Shaft J Right Hand Output Shaft Gear Reducer Suffix: Universal Series A 56C or Right Hand Output Shaft B 140TC C 180TC Grinder Catalog Number Suffix: D Deluxe E Exhaust Guards W Wide Design Other Abbreviations: C Permanent Split Capacitor L Capacitor-Start, Induction-Run Motor LC Capacitor-Start, Capacitor-Run Motor S Split Phase X Explosion-Proof Approvals UL and CSA General Information General Information UL Recognition for NEMA frames E46145 180-449 — UL Recognition for NEMA frames E54825 42-184 Subfractional motor and gearmotors UL Recognition for DC frames E46145 48-4013AT — UL Recognition for DC frames E54825 L180-DL2814 — UL Recognition for AC frames E54825 440 & 5800 — UL Recognition for AC frames E54825 42-449 — CSA Certification for NEMA frames LR2262 180-449 600 max. CSA Certification for NEMA frames LR7861 42-184 Fractional and Integral CSA Certification for DC frames LR2262 42-184 Integral Wound Field Build in Ft. Mill CSA Certification for DC frames LR36841-5 48-4013AT 5-500 CSA Certification for DC frames LR40567 L180-DL2814 32-1000 CSA Certification for AC frames LR40567 7MG-80MG 15-150 CSA Certification for MG Sets LR40567 C4412-B1610 527-3000 CSA Certification for DC frames LR52580 447T-7111 500-1500 CSA Certification for AC frames LR52580 5000-5800 900(2P),800(4P),700(6P)4160Vmax CSA Certification for AC frames LR36841-7 5800-1000 1000-15000 CSA Certification for AC frames LR6451 447T-7111 500-1500 CSA Certification for Finned AC frames LR52580 5800-1000 1000-15000 CSA Certification for O5800 AC frames LR6451 General Purpose Industrial Motors — LR40567 Baldor Product Designs Reliance Product Designs EPAct Compliance Certification: CC 010A and CC 049A Premium Efficient Super-E® Motors 42-449 Severe Duty Motors Comments Washdown Duty Motors Hp Explosion Proof Motors Frame Single Phase Motors Approvals for AC Motors, Explosion Proof, and DC Motors: AC Inverter and Vector Controls — Baldor and Baldor V*S Drives are UL/cUL Listed, file number E128059. Reliance Drives are UL/cUL Listed, file number E59092. Commercial Motors DC SCR Controls and Accessories — Controls with catalog numbers BC138, BC139, BC140, BC140-FBR, BC141, BC142, BC155, BC154, BCWD140, BC160, BC200, BC201, BC202, BC203 and BC204 and accessories BC24-LF, BC145, BC146, BC147, BC151, BC211 and BC212 are UL listed for US and Canada, UL file number E114039. BC153 is UL component recognized for US and Canada. BC254, BC354, BC214, BC215, BC216, BC217, BC218, BC245, BC253, BC258, BC259, DSP4-120, DSP4240, DTM8000-120, DTM8000-240, HPU10, RK60-56 and RK60-145 are pending – contact Baldor for status. Larger SCR controls Series 19H and 20H are UL and cUL Listed, UL file number E128059. SCR controls Series 29D and 30D are UL and cUL listed, UL file E128059. Reliance DC are Drives UL/cUL Listed, file number E59092. Pump Motors DC Tachometers — XPY tachometers are UL recognized, file number E109527 and CSA listed file number LR36841-5. HVAC Motors AC Soft Starters — All units are CUL listed, file number E114039 except catalog item S25CA. ­