SolaHD DIN Rail Power Supply Solutions Providing the right DIN rail power supply for your application needs. 0 PROVIDING THE RIGHT DIN RAIL POWER SUPPLY FOR YOUR APPLICATION NEEDS 1 SVL: ESSENTIAL PERFORMANCE FOR CONTROLLED ENVIRONMENTS Industries/Applications Oil Rigs Pharmaceutical Food Mills Process Refinery Metal Mining Industrial Control Conveyor Systems Material Handling Packaging Systems DeviceNet Semiconductor Fabrication Vending Machines Test & Measure Scanners Instrumentation ATM Machines 2 SDN-P & SDP: CORE PERFORMANCE FOR INDUSTRIAL PROCESSES Industries/Applications Oil Rigs Pharmaceutical Food Mills Process Refinery Metal Mining Industrial Control Conveyor Systems Material Handling Packaging Systems DeviceNet Semiconductor Fabrication Vending Machines Test & Measure Scanners Instrumentation ATM Machines 3 SDN-C: HIGHEST PERFORMANCE FOR EXTREME APPLICATIONS Industries/Applications Oil Rigs Pharmaceutical Food Mills Process Refinery Metal Mining Industrial Control Conveyor Systems Material Handling Packaging Systems DeviceNet Semiconductor Fabrication Vending Machines Test & Measure Scanners Instrumentation ATM Machines 4 GLOBAL OEM SAFETY STANDARD REQUIREMENTS Approvals Ordinary Location Hazardous Location Offshore Location North America cULus, cCSAus, cURus, cCSAus, GOST P UL/CSA 508 Listed for use as Industrial Control Equipment Recognized for use as Information Technology Equipment, Level 5; U.S.A. (UL 60950-1) and Canada (C22.2 No. 60950-1) UL/CSA 60079 Class 1, Zone 2, Groups A, B, C, D Recognized component used in hazardous locations Class 1 Zone 2, Groups A, B, C, D systems ABS, IECEx American Bureau for Shipping, PDA Environmental category: C, EMC2 Marine and offshore applications (humidity, corrosion, shock & vibration, ground leakage current) European Union CE, GOST P Conformance with the EMC directive 2004/108/EC , the low voltage directive (LVD) 2006/95/EC and the RoHS directive 2011/65/EC; GUS Russia and GUS Countries CoC ATEX Suitable for use in Class 1 Zone 2 Groups IIa, IIb and IIc locations. The power supply must be built-in in an IP54 enclosure. GL, IECEx Germanischer Lloyd classified and Environmental category: C, EMC2 Marine and offshore applications Asia Australia IECEx CCC, GOST P Compliance with hazardous Certificate of Conformity for Russia requirements per IEC standards. and other GUS countries Product does not require additional CCC Chinese CoC testing. C-Tick CoC for Australia IECEx ABS/GL, IECEx ABS/GL, IECEx Our customers are OEM’s based in North America. Their customer’s are Global and require global certifications. 5 A MORE ROBUST DESIGN IS REQUIRED TO MEET HIGHER CERTIFICATION REQUIREMENTS Products with higher level of certification need a more complex design. They are required to pass more rigorous testing to meet the standards required for use in more demanding applications. • PC boards are designed with additional space between copper traces, multiple layers, and thicker insulation to prevent arcing and sparking. • Temperature build up is a critical factor to prevent thermal ignition. SolaHD uses state of the art technology, efficient components and exotic materials to control losses. • Relays are electromagnetic switches which by nature create arcs therefore these must be encapsulated and tested to ensure they will not ignite hazardous vapors. 6 CHOOSE THE RIGHT FEATURES FOR YOUR APPLICATION PERFORMANCE SDN-C CORE SDN-P/SDP ESSENTIAL SVL 5 years 5 years / 3 years 2 years >800,000 hours >500,000 hours >350,000 hours >92% typical >84% typical >79% typical — — 8 visual diagnostics DC OK LED DC OK LED Operation –40°C to +70°C –10°C to +70°C –20°C to +70°C Power derating Starts at +60°C Starts at +60°C Starts at +50°C Clips easy to DIN rail No Tools required to dismount — ATEX/IECEx, ABS, GL, GHOST — — UL 508 (industrial control equip.) UL 60950 Benefits Reliability Features Warranty MTBF Efficiency Handling heat dissipation PowerBoost 1.5 × nominal current for 4 seconds minimum while holding voltage Easy Troubleshooting Diagnostics Temperature Flexible Mounting Safety Approvals This table is an overview of the entire power supply offering. Individual model specifications may vary. For detailed information on individual models, 7 please consult the SolaHD catalog. PERFORMANCE: WHERE SHOULD YOU USE THE SDN-C SERIES? The SDN-C Series is built tough for use in extreme applications • Harsh environments • Extreme temperatures (–40°C to +60°C) • Critical equipment and processes that depend on the highest level of machine availability Models available for use in hazardous locations: • ATEX/IECEx Certified • Ex EAC • Class I, Division 2 • Class I, Zone 2 8 PERFORMANCE: HOW DOES THE SDN-C SERIES BENEFIT YOUR APPLICATION? Highest Efficiency: • Lower energy consumption • Lower cooling costs • No derating Easiest to Use: • Simple installation • Universal input voltage with sag immunity • Eight quick visual diagnostics Greatest Reliability: • PowerBoost technology • Fewer components • Less heat • Five year warranty 9 CORE: WHERE SHOULD YOU USE THE SDN-P AND SDP SERIES? The SDN-P and SDP Series are the standard choice for most industrial applications: • Rugged and resistant to shock and vibration • Wide temperature range (–10°C to +60°C) • Reliable performance for maximum machine availability SDP Low Power Series, single-phase: • 5–48 Vdc, up to 5 Amps SDN-P Series, single- or three-phase: • 12–48 Vdc, up to 40 Amps 10 CORE: HOW DO THE SDN-P AND SDP SERIES BENEFIT YOUR APPLICATION? Efficient: • Power factor correction • Low losses • Adjustable voltage Easy to Use: • Simple installation • Universal input voltage • DC OK LED Reliable: • Rugged case and DIN connector • Trouble-free performance, with short circuit and overvoltage protection • Three year warranty for SDP Low Power Series • Five year warranty for SDN-P Series 11 ESSENTIAL: WHERE SHOULD YOU USE THE SVL SERIES? The SVL Series is best suited for high-volume applications: • Controlled environments • Standard operating temperatures • Compact footprint • ATMs, vending machines, building automation, light industry, life sciences etc. 12 ESSENTIAL: HOW DOES THE SVL SERIES BENEFIT YOUR APPLICATION? Easy Design Integration: • High power density in a small frame • Universal input voltage Quick Installation: • Simple to wire • Trouble-free mounting Practical Operation: • Reliable power for applications in a controlled environment • LED indicator for visual verification • Two year warranty 13 TECHNICAL DATA: ESSENTIAL VS CORE VS PERFORMANCE CORE Feature ESSENTIAL SVL Series PERFORMANCE SDN-C Series SDP Series SDN-P Series Power Range 15–480 W single phase 15–100 W single phase 6–240 W single phase 120–960W single phase 120–960W three phase Input Input Voltage Range 85–264 Vac, 120–375 Vdc 85–264 Vac, 90–375 Vdc 85–132/176–264 Vac, 210–375 Vdc 85–264 Vac, 90–375 Vdc, 320–540 Vac, 450–760 Vdc Efficiency >79% typ. > 80% > 88% typ. > 90% Power Factor Correction Available in select models Passive Passive Active Output Nominal Voltage Range 5–48V 5–48V 12–48V 24V Ripple/Noise (+25 °C) < 100mVpp < 50 mVpp < 50 mVpp < 50 mVpp Nominal Current Range 1.25–20 A 0.6–5 A 2.5–10 A 5–40A Regulation <0.5% line and <1% Load < 2% line and load < ±2 % overall line and load < 0.5% line and load 16 Power Boost ✓ ✓ TECHNICAL DATA: ESSENTIAL VS CORE VS PERFORMANCE Feature ESSENTIAL SVL Series CORE SDP Series SDN-P Series PERFORMANCE SDN-C Series Environmental Data Operating Temperature –20°C to +70°C –10°C to +60°C –10°C to +60°C –10°C to +60°C Storage Temp –40°C to +85°C –25°C to 85°C –25 to +85°C –40 to +85°C Power Derating Starts at +50°C Starts at +60°C Starts at +60°C Starts at +60°C Protections 17 Overvoltage Protection Latch mode Auto-recovery Auto-recovery Auto-recovery Overload Protection Auto-recovery Auto-recovery Auto-recovery Auto-recovery Short Circuit Protection Auto-recovery Auto-recovery Auto-recovery Auto-recovery TECHNICAL DATA: ESSENTIAL VS CORE VS PERFORMANCE Feature ESSENTIAL SVL Series CORE SDP Series SDN-P Series PERFORMANCE SDN-C Series Reliability MTBF >350 khrs to >700khrs per Telcordia >500 khrs per Telcordia >500 khrs to >820 khrs per Telcordia > 800 khrs per Telecordia General LED Signals Green DC OK LED, Blinking OCP DC OK LED DC OK LED 8 visual diagnostics DC OK Relay Contact Available in select models ✓ ✓ ✓ Warranty 2 year 3 year 5 year 5 year 18 QUESTIONS? 19 Visit SolaHD.com for more information all our products, including our complete family of DIN rail transformers. www.solahd.com 20