MDR-120S Compact, 120W DIN Rail Mount AC/DC Power Supply Electrical Specifications Key Features: Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Input • 120W Output Power Parameter • EN 60950 Approved Input Voltage Range • Compact, DIN Rail Case Input Frequency • Active PFC Inrush Current, See Note 1 • 85-264 VAC Input Power Factor Correction Conditions 115 VAC 230 VAC 115 VAC 230 VAC Start Up Shut Down • TS-35/7.5 or TS-35/15 Rails • Meets EN 55022 B Min. 85 120 47 Input Under Voltage Shutdown Typ. 35 70 0.98 0.96 76 67 Output • Remote ON/OFF Control Parameter Output Voltage Accuracy Output Voltage Adjust Line Regulation Load Regulation Ripple & Noise (20 MHz) Hold-Up Time Temperature Coefficient Over Temperature Protection Over Voltage Protection Short Circuit Protection, See Note 3 Overload Protection, See Note 4 Conditions Min. Typ. VIN = Min to Max IOUT = 10% to 100% 25.0 ±0.03 Auto-Recovery 95 See Note 2 30 Continuous (Auto-Recovery) Auto-Recovery 110 Units VAC VDC Hz A Pk 83 75 1.5 Start Up Time • High Efficiency Max. 264 370 63 VAC S Max. ±1.0 ±5.0 ±0.5 ±1.0 100 Units % % % % m V P-P mS %/°C °C VDC 150 %IOUT Max. Units 115/230 VAC General Parameter Conditions Input to Output Input to Output to Isolation Voltage, 60S Switching Frequency EMI Characteristics, See Note 5 Parameter Radiated Emissions Conducted Emissions ESD MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com RS EFT Surge CS PFM Voltage Dips, Interruptions Min. 3,000 1,500 500 Typ. VAC 100 Standard Criteria EN 55024 EN 55022 EN 61000-4-2 B EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 EN 61000-4-8 EN 61000-4-11 A B B A A B kHz Level Class B Class B ±8 kV Air ±6 kV Contact 10V/m ±4 kV ±2 kV/ ±4 kV 10 Vrms 10A/m 0% - 70% Environmental Parameter Operating Temperature Range Storage Temperature Range Cooling Humidity Conditions Min. Typ. Max. -25 +25 +70 -25 +85 Free Air Convection (See Derating Curve on Page 2) RH, Non-condensing 95 Ambient Units °C °C % Physical Case Size Case Material Weight See Mechanical Diagram (Page 2) Heat Resistant Plastic (UL94-V0) and Metal 18.9 Oz (560g) Reliability Specifications Parameter MTBF Safety Standards Safety Class Conditions Min. MIL HDBK 217F, 25°C, Gnd Benign 300 EN 60950 Class I Typ. www.micropowerdirect.com Max. Units kHours www.micropowerdirect.com Model Selection Guide Model Number MDR-120S-24 Input Current (A Max) Voltage 115 VAC 230 VAC (VDC) 1.5 0.75 24.0 Output Current (A) Max. Min. 5.0 Efficiency (%, Typ) Standby Capacitive Power Load Consumption (µF Max) (W Max) 0.0 92 4,700 0.75 Derating Curve, Temperature Other outputs may be available Contact the factory for details at: sales@micropowerdirect.com Notes: 1. Inrush current is given for a cold start at 25°C. 2. Over voltage protection is provided by a zener diode clamp. 3. Output short circuit protection is provided by a “hiccup mode” circuit. The unit recovers automatically when the fault condition is removed. 4. Output overload protection is provided by a fold back current limiting circuit with auto-recovery. A long-term overload could damage the unit. 5. EMI characteristics are specified without external components. 6. Operation at no-load will not damage these units. However, they may not meet all specifications. 7. Applying a voltage level of 4.5 to 12.5 VDC across the control terminals (see mechanical diagram) will turn the unit off. When the control inputs are left open, the unit will operate normally. 8. The MDR-120S is designed for mounting on a standard 35 mm DIN rail (TS35). 9. It is recommended that an external slow blow fuse also be used on the input for protection. Contact the factory for more information. Derating Curve, Input Voltage Mechanical Dimensions Wire Connections Pin Function 1 2 3 4 5 6 7 +VOUT +VOUT -VOUT -VOUT AC-Neutral AC-Line Notes: • All dimensions are typical in inches (mm) • Wire Range is: 26 - 10 AWG, Strip length is 0.32 (8.0) • Tolerance x.xx = ±0.04 (±1.0) MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com