HFA08PB60 - Semiconductors

advertisement
Bulletin PD-20050 01/01
HFA08PB60
HEXFRED
Ultrafast, Soft Recovery Diode
TM
Features
•
•
•
•
•
VR = 600V
BASE
CATHODE
Ultrafast Recovery
Ultrasoft Recovery
Very Low IRRM
Very Low Qrr
Specified at Operating Conditions
VF(typ.)* = 1.4V
4
IF(AV) = 8.0A
Qrr (typ.)= 65nC
2
IRRM = 3.5A
Benefits
• Reduced RFI and EMI
• Reduced Power Loss in Diode and Switching
Transistor
• Higher Frequency Operation
• Reduced Snubbing
• Reduced Parts Count
1
CATHODE
trr(typ.) = 18ns
3
ANODE
2
di(rec)M/dt (typ.)* = 210A/µs
Description
International Rectifier's HFA08PB60 is a state of the art center tap ultra fast
recovery diode. Employing the latest in epitaxial construction and advanced
processing techniques it features a superb combination of characteristics which
result in performance which is unsurpassed by any rectifier previously available.
With basic ratings of 600 volts and 8 amps continuous current, the HFA08PB60
is especially well suited for use as the companion diode for IGBTs and
MOSFETs. In addition to ultra fast recovery time, the HEXFRED product line
features extremely low values of peak recovery current (IRRM) and does not
exhibit any tendency to "snap-off" during the tb portion of recovery. The
HEXFRED features combine to offer designers a rectifier with lower noise and
significantly lower switching losses in both the diode and the switching transistor.
These HEXFRED advantages can help to significantly reduce snubbing,
component count and heatsink sizes. The HEXFRED HFA08PB60 is ideally
suited for applications in power supplies and power conversion systems (such
as inverters), motor drives, and many other similar applications where high
speed, high efficiency is needed.
TO-247AC (Modified)
Absolute Maximum Ratings
Parameter
VR
IF @ TC = 25°C
IF @ TC = 100°C
IFSM
IFRM
PD @ TC = 25°C
PD @ TC = 100°C
TJ
TSTG
Cathode-to-Anode Voltage
Continuous Forward Current
Continuous Forward Current
Single Pulse Forward Current
Maximum Repetitive Forward Current
Maximum Power Dissipation
Maximum Power Dissipation
Operating Junction and
Storage Temperature Range
Max
Units
600
V
8.0
60
24
36
14
-55 to +150
A
W
C
* 125°C
1
HFA08PB60
Bulletin PD-20050 01/01
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
V BR
Cathode Anode Breakdown Voltage
VFM
Max Forward Voltage
IRM
Max Reverse Leakage Current
CT
LS
Min Typ Max Units
Junction Capacitance
600
–––
–––
–––
–––
–––
–––
–––
1.4
1.7
1.4
0.3
100
10
–––
1.7
2.1
1.7
5.0
500
25
Series Inductance
–––
8.0
–––
V
V
µA
pF
nH
Test Conditions
IR = 100µA
IF = 8.0A
See Fig. 1
IF = 16A
IF = 8.0A, TJ = 125°C
See Fig. 2
VR = VR Rated
TJ = 125°C, VR = 0.8 x VR RatedD Rated
See Fig. 3
VR = 200V
Measured lead to lead 5mm from
package body
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter
t rr
trr1
trr2
IRRM1
IRRM2
Qrr1
Qrr2
di(rec)M/dt1
di(rec)M/dt2
Reverse Recovery Time
See Fig. 5, 10
Peak Recovery Current
See Fig. 6
Reverse Recovery Charge
See Fig. 7
Peak Rate of Fall of Recovery Current
See Fig. 8
During tb
Min Typ Max Units
18
37
55
3.5
4.5
65
124
240
210
55
90
5.0
8.0
138
360
ns
A
nC
A/µs
Test Conditions
IF = 1.0A, dif/dt = 200A/µs, VR = 30V
TJ = 25°C
TJ = 125°C
IF = 8.0A
TJ = 25°C
TJ = 125°C
VR = 200V
TJ = 25°C
TJ = 125°C
dif/dt = 200A/µs
TJ = 25°C
TJ = 125°C
Thermal - Mechanical Characteristics
Parameter
Tlead!
RθJC
RθJA"
RθCS#
Lead Temperature
Thermal Resistance, Junction to Case
Thermal Resistance, Junction to Ambient
Thermal Resistance, Case to Heat Sink
Wt
Weight
Mounting Torque
!
"
#
2
Min
Typ
Max
Units
––––
––––
––––
––––
––––
––––
6.0
5.0
––––
––––
––––
0.25
6.0
0.21
––––
––––
300
3.5
40
––––
––––
––––
12
10
°C
K/W
g
(oz)
Kg-cm
lbf•in
0.063 in. from Case (1.6mm) for 10 sec
Typical Socket Mount
Mounting Surface, Flat, Smooth and Greased
www.irf.com
HFA08PB60
Bulletin PD-20050 01/01
Reverse Current - IR (µA)
1000
10
TJ = 150°C
TJ = 125°C
TJ = 150°C
100
TJ = 125°C
10
1
0.1
TJ = 25°C
0.01
0.001
0
100
TJ = 25°C
300
400
500
600
Fig. 2 - Typical Reverse Current vs. Reverse
Voltage
1
100
0.1
0.4
200
Reverse Voltage - V R (V)
0.8
1.2
1.6
2.0
2.4
2.8
3.2
Forward Voltage Drop - V FM (V)
Fig. 1 - Maximum Forward Voltage Drop
vs. Instantaneous Forward Current
Junction Capacitance -CT (pF)
Instantaneous Forward Current - IF (A)
100
A
TJ = 25°C
10
1
1
10
100
1000
Reverse Voltage - V R (V)
Fig. 3 - Typical Junction Capacitance vs.
Reverse Voltage
Thermal Response (Z thJC )
10
D = 0.50
1
0.20
0.10
0.05
0.1
0.01
0.00001
0.02
0.01
P DM
SINGLE PULSE
(THERMAL RESPONSE)
t1
t2
Notes:
1. Duty factor D = t 1 / t 2
2. Peak T J = P DM x Z thJC + TC
0.0001
0.001
0.01
0.1
1
t1 , Rectangular Pulse Duration (sec)
Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics
www.irf.com
3
HFA08PB60
Bulletin PD-20050 01/01
20
80
VR = 200V
TJ = 125°C
TJ = 25°C
I F = 16A
IFF = 8.0A
I F = 4.0A
16
I F = 16A
60
I F = 8.0A
Irr- ( A)
trr- (nC)
I F = 4.0A
40
12
8
20
4
VR = 200V
TJ = 125°C
TJ = 25°C
0
100
di f /dt - (A/µs)
0
100
1000
1000
Fig. 6 - Typical Recovery Current vs. dif/dt,
(per Leg)
Fig. 5 - Typical Reverse Recovery vs. dif/dt,
(per Leg)
500
10000
VR = 200V
TJ = 125°C
TJ = 25°C
400
di f /dt - (A/µs)
VR = 200V
TJ = 125°C
TJ = 25°C
I F = 16A
di (rec) M/dt- (A /µs)
IF = 8.0A
IF = 4.0A
Qrr- (nC)
300
200
IF = 16A
I F = 8.0A
IF = 4.0A
1000
100
0
100
di f /dt - (A/µs)
1000
Fig. 7 - Typical Stored Charge vs. dif/dt,
(per Leg)
4
100
100
di f /dt - (A/µs)
1000
Fig. 8 - Typical di(rec)M/dt vs. dif/dt,
(per Leg)
www.irf.com
HFA08PB60
Bulletin PD-20050 01/01
3
t rr
IF
REVERSE RECOVERY CIRCUIT
tb
ta
0
Q rr
VR = 200V
2
I RRM
4
0.5 I RRM
di(rec)M/dt
0.01 Ω
L = 70µH
D.U.T.
dif/dt
ADJUST
D
G
IRFP250
S
Fig. 9 - Reverse Recovery Parameter Test
Circuit
www.irf.com
5
0.75 I RRM
1
di f /dt
1. dif/dt - Rate of change of current
through zero crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured
from zero crossing point of negative
going IF to point where a line passing
through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
4. Qrr - Area under curve defined by trr
and IRRM
trr X IRRM
Qrr =
2
5. di(rec)M/dt - Peak rate of change of
current during tb portion of trr
Fig. 10 - Reverse Recovery Waveform and
Definitions
5
HFA08PB60
Bulletin PD-20050 01/01
Conforms to JEDEC Outline TO-247AC MODIFIED
Dimensions in millimeters and inches
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 01/01
6
www.irf.com
Download