B Two-wire Signal Conditioners High performance transmitters in various housing styles Head-mount, Field-mount and DIN rail mount transmitters are available for various classified/non-classified environments. Two-wire isolators draw power from the 4 – 20mA process signal loop, no additional power supply or lines is required which can save on wiring costs. ISP1-1 75 B Head-mounted Two-wire Signal Conditioners 27-UNIT Series 4-wire Signal Conditioners 2-wire Signal Conditioners Power Transducers I/O range programming via PC Configurator HART communication capability. ATEX and FM approval n Function monitor LED optional (27R, 27RS) Indicators n HART programmable (27HU, 27HU-B) n 4-digit LED indicator optional (27HU-B) Limit Alarms Gateway, Remote I/O Paperless Recording System PC Recorder s SPECIFICATIONS s SPECIFICATIONS (model: 27HU-B) Electronic Actuators & Position Sensors Construction Construction Degree of protection Transmitter material • Housing • Electrical connection s EXTERNAL DIMENSIONS Flame-resistant resin (black) Terminal block Diecast aluminium standard; stainless steel casting optional (equivalent to type 316); silver color, epoxy resin coated Mounting bracket assembly Stainless steel 304 Applicable pipe 1 1/2” min.; 2” max. Isolation Input to output to outdoor enclosure 6-UNIT Series T-UNIT Series 6 (.24) dia. 2–G 1/2 or 1/2NPT or M20x1.5 or PG13.5 – 1 4 2 110 (4.33) 3 39 (1.54) dia. + 12.7 (.5) 78 (3.07) max. 174 (6.85) 2–4.5 (.18) dia. MTG HOLE 27HU-B 19.5 (.77) 16.5 (.65) 114 (4.49) 19 (.75) 33 (1.30) 78 (3.07) max. 6.3 B5-UNIT Series 27xx 20.7 (.81) 5) B3-UNIT Series mm (inch) 44 (1.73) dia. (.2 B6-UNIT Series Two-wire Signal Conditioners 26-UNIT Series Flame-resistant resin (black) M3 screw terminals (nickel-plated brass; torque 0.5 N·m) Indicator material • Housing • Electrical connection Enclosure material Two-wire Product Selection Guide 27-UNIT Series Outdoor enclosure NEMA 4X, IP65 110 (4.33) dia. Lightning Surge Protectors Sensor head-mounting M3 screw terminals Connection (nickel-plated brass; torque 0.5 N·m) Housing material Flame-resistant resin (black) Isolation Input to output Cold junction compensation CJC sensor incorporated Self diagnostics Detects internal error, burnout Mounting Head-mounting (DIN type B head) Supply voltage 9 – 35V DC (non-approved) Dielectric strength 1500V AC @1 minute (input to output) 6–M3 SCREW B-UNIT Series n Field-mounted Transmitters Model Function 27HU-B 2-wire Universal Temperature Transmitter (HART communication, outdoor enclosure, explosion-proof) n Head-mounting Transmitters n Accessories, Related Products Page P.79 Model Function Page 27HU 2-wire Universal Temperature Transmitter (HART communication) 27U 2-wire Universal Temperature Transmitter (PC programmable) P.80 27TS Thermocouple Transmitter (PC programmable) P.80 27R RTD Transmitter (PC programmable; non-isolated) P.81 27RS RTD Transmitter (PC programmable) P.81 P.79 Model Function A-6 Mounting Spacer Page A-34 DIN Rail Mounting Adaptor 6DV 4-digit Loop Powered Indicator (intrinsically safe) *** P.131 6DVI 4-digit Loop Powered Indicator (intrinsically safe) P.131 6BX-E Outdoor Enclosure *** COP-H Bell202 Modem (RS-232C interface) *** COP-HU Bell202 Modem (USB interface) *** M2DYH Current Loop Supply (applicable to HART signal) P.19 A3DYH Current Loop Supply (applicable to HART signal) *** *** To find a product in the list with “***”, visit M-System Data Library. If you cannot find a product here, please contact: info@m-system.co.jp 78 Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1 B Head-mounted Two-wire Signal Conditioners 26-UNIT Series Four-wire Signal Conditioners Two-wire Signal Conditioners Accepts direct input from RTD or T/C and provides a standard 4 – 20mA DC signal Power Transducers n Suitable for DIN B type head Indicators n Linearization, burnout protection, cold junction compensation (T/C input) standard n Optional 25 msec. response time selectable for 26TS1 and 26RS Limit Alarms Gateway, Remote I/O Paperless Recording System PC Recorder Electronic Actuators & Position Sensors Lightning Surge Protectors s SPECIFICATIONS Two-wire Product Selection Guide Construction Connection Housing material Mounting Supply voltage Operating temperature Operating humidity s EXTERNAL DIMENSIONS 26REX Sensor head-mounting Terminal block Flame-resistant resin (black) Head-mounting (DIN type B head) 12 – 30V DC -40 to +80°C (-40 to +176°F) 0 to 90% RH (non-condensing) ZERO ADJ. mm (inch) 26.5 (1.04) 15.5 (.61) 43.5 (1.71) dia. 33 (1.30) SPAN ADJ. 7.0 (.28) dia. 2–4.2 (.17) dia. MTG HOLE 1 2 3 4 5 26-UNIT Series B6-UNIT Series B3-UNIT Series B5-UNIT Series 6-UNIT Series T-UNIT Series B-UNIT Series Two-wire Signal Conditioners 27-UNIT Series Model Function 26TS1 Thermocouple Transmitter Page P.83 26REX RTD Transmitter (intrinsically safe; non-isolated) P.83 26R1 RTD Transmitter (non-isolated) P.83 26RS RTD Transmitter P.83 n Accessories, Related Products Model Function A-34 DIN Rail Mounting Adaptor Page A-6 Mounting Spacer 6DV 4-digit Loop Powered Indicator (intrinsically safe) *** P.131 6DVI 4-digit Loop Powered Indicator (intrinsically safe) P.131 *** To find a product in the list with “***”, visit M-System Data Library. If you cannot find a product here, please contact: info@m-system.co.jp 82 Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1 B Field-mounted Two-wire Signal Conditioners B6-UNIT Series Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators M-System’s Models B6U and B6U-B accept a wide variety of inputs including thermocouples and RTDs as well as mV, resistance and potentiometer sensor types. n Plug-in two-line LCD display n HART programmable n AMS software version 6.0 or higher Limit Alarms n Stainless steel enclosure optional Gateway, Remote I/O n ATEX Zone 0 approvals Paperless Recording System n FM Class I, II, III, Division 1 approvals PC Recorder Electronic Actuators & Position Sensors s SPECIFICATIONS (model: B6U) s SPECIFICATIONS (model: B6U-B) HART communication, intrinsically safe Electrical connection Materials • Transmitter housing • Screw terminals Isolation Construction Degree of protection Wiring conduit Electrical connection Materials • Transmitter housing • Screw terminals • Enclosure material M3.5 screw terminals (torque 0.8 N·m) Flame-resistant resin (black) Nickel-plated brass Input to output T-UNIT Series B-UNIT Series 2 3 4 48 (1.89) 34.5 (1.36) mm (inch) 1 2 3 4 – + s EXTERNAL DIMENSIONS (model: B6U-B) 78 (3.07) max. 114 (4.49) 110 (4.33) 2–G 1/2 or 1/2NPT or M20x1.5 or PG13.5 2–5 (.197) dia. MTG HOLE 24.5 (.965) deep LCD MODULE CONNECTOR HHC TERMINAL Without LCD Module With LCD Module (Terminal Assignments) Leave enough space at both sides of the module to reach the side levers when installing/removing the LCD module. *Two sets of cable gland are attached with TIIS flameproof option. n Accessories, Related Products Model Function B6U-B 2-wire Universal Temperature Transmitter (HART communication, intrinsically safe/explosion-proof) B6U 2-wire Universal Temperature Transmitter (HART communication, intrinsically safe) mm (inch) 78 (3.07) max. 19 (.75) 1 63 (2.48) max. 39 (1.54) dia. 6-UNIT Series 59 (2.32) dia. 33 (1.30) 174 (6.85) B5-UNIT Series s EXTERNAL DIMENSIONS (model: B6U) 27.5 (1.08) 24.5 (.96) B3-UNIT Series Two-wire Signal Conditioners 27-UNIT Series B6-UNIT Series Outdoor enclosure NEMA 4X, IP65 G 1/2, 1/2 NPT, M20 × 1.5, PG 13.5 M3.5 screw terminals (torque 0.8 N·m) Flame-resistant resin (black) Nickel-plated brass Diecast aluminium standard; stainless steel casting optional (equivalent to type 316); silver color, epoxy resin coated • Mounting bracket assembly Stainless steel 304 Applicable pipe 1 1/2” min.; 2” max. Isolation Input to output to outdoor enclosure Two-wire Product Selection Guide 26-UNIT Series mm (inch) HART communication, intrinsically safe/explosion-proof 110 (4.33) dia. Lightning Surge Protectors Model Function P.85 A-34 DIN Rail Mounting Adaptor *** COP-H Bell202 Modem (RS-232C interface) *** P.85 COP-HU Bell202 Modem (USB interface) *** M2DYH Current Loop Supply (applicable to HART signal) P.19 A3DYH Current Loop Supply (applicable to HART signal) *** Page Page To find a product in the list with “***”, visit M-System Data Library. If you cannot find a product here, please contact: info@m-system.co.jp 84 Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1 B Space-saving Two-wire Signal Conditioners B3-UNIT Series Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators DIN rail mounted, input configurable two-wire transmitters. n Input type and range selectable with the internal DIP switches and fine calibration using the front potentiometers n Wide supply voltage range 12–45V DC Limit Alarms n Eliminates noise and prevents ground loops with 2000V AC isolation Gateway, Remote I/O Paperless Recording System n B3HU / B3PU 1500V AC isolation between input and output PC Recorder Electronic Actuators & Position Sensors s SPECIFICATIONS s EXTERNAL DIMENSIONS GENERAL SPECIFICATIONS 10 11 12 Front terminal access Removable terminal block Flame-resistant resin (grey) Input to output DIN RAIL 35mm wide 106 (4.17) Construction Connection Housing material Isolation INSTALLATION Supply voltage Two-wire Product Selection Guide Operating humidity Mounting Dielectric strength B3-UNIT Series B5-UNIT Series 6-UNIT Series T-UNIT Series 12 – 45V DC -40 to +85°C (-40 to +185°F) Max. 55°C (131°F) for UL approval 0 to 95% RH (non-condensing) DIN rail 2000V AC @1 minute (input to output to ground) 4 5 6 18 (.71) 110.5 (4.35) [3.3 (.13)] • When mounting, no extra space is needed between units. OUTPUT Output 4 – 20mA DC Load resistance vs. supply voltage: 1650 1600 1400 1200 Supply Voltage (V) – 12 (V) Load Resistance (Ω) = –––––––––––––––––––– 1000 0.02 (A) 800 (including leadwire resistance) 600 LOAD RESISTANCE [7] B6-UNIT Series Two-wire Signal Conditioners 27-UNIT Series 26-UNIT Series Operating temperature mm (inch) 62 (2.44) Lightning Surge Protectors 400 200 0 10 12 20 30 40 45 SUPPLY VOLTAGE [V] (6007 maximum at 24V DC) B-UNIT Series Model Function Page B3HU 2-wire Universal Temperature Transmitter (HART communication, intrinsically safe) P.87 B3PU 2-wire Universal Temperature Transmitter (PROFIBUS-PA) P.88 B3FV Signal Transmitter (field-configurable) P.88 B3VS/1 Signal Transmitter (single-channel output loop powered isolator) P.88 B3VS/2 Signal Transmitter (dual-channel output loop powered isolator) P.88 B3FT Thermocouple Transmitter (field-configurable) P.89 B3FR RTD Transmitter (field-configurable) P.89 B3FP Frequency Transmitter (field-configurable) P.89 n Accessories, Related Products Model Function COP-H Bell202 Modem (RS-232C interface) Page *** COP-HU Bell202 Modem (USB interface) *** M2DYH Current Loop Supply (applicable to HART signal) P.19 A3DYH Current Loop Supply (applicable to HART signal) *** To find a product in the list with “***”, visit M-System Data Library. If you cannot find a product here, please contact: info@m-system.co.jp 86 Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1 B Super-mini Two-wire Terminal Block Signal Conditioners B5-UNIT Series Four-wire Signal Conditioners Two-wire Signal Conditioners Power Transducers Indicators Only 41 mm (1.6 in.) deep modules can be installed anywhere, even behind the panel cover. n 41 mm (1.6”) deep n Linearization, burnout protection, cold junction compensation (T/C input) standard Limit Alarms n Optional 25 msec. response time selectable Gateway, Remote I/O n Power indicator LED Paperless Recording System PC Recorder Electronic Actuators & Position Sensors Lightning Surge Protectors s SPECIFICATIONS s EXTERNAL DIMENSIONS 7.3 (.29) GENERAL SPECIFICATIONS Connection Housing material Isolation Power LED 26-UNIT Series B6-UNIT Series B3-UNIT Series B5-UNIT Series 6-UNIT Series T-UNIT Series Two-wire Signal Conditioners Supply voltage Operating temperature Operating humidity Mounting Dielectric strength 12 – 28V DC -40 to +80°C (-40 to +176°F) 0 to 90% RH (non-condensing) DIN rail 2000V AC @1 minute (input to output to ground) DIN RAIL 35mm wide 4 5 6 7 8 25 (.98) 41 (1.61) [3.3 (.13)] • When mounting, no extra space is needed between units. OUTPUT Output 4 – 20mA DC Load resistance vs. supply voltage: 800 Supply Voltage (V) – 12 (V) Load Resistance (Ω) = –––––––––––––––––––– 0.02 (A) (including leadwire resistance) 600 400 200 0 10 12 15 20 25 28 SUPPLY VOLTAGE [V] (6007 maximum at 24V DC) B-UNIT Series 90 2 3 3 (.12) 27-UNIT Series 1 INSTALLATION LOAD RESISTANCE [7] Two-wire Product Selection Guide Terminal block M3.5 screw terminals (nickel-plated steel; torque 0.8 N·m) Flame-resistant resin (black) Input to output Orange light turns on when the power is supplied. 94 (3.70) Construction mm (inch) 8–M3.5 SCREW Model Function Page B5SN Input Loop Powered Isolator P.91 B5VS Signal Transmitter P.91 B5TS Thermocouple Transmitter P.91 B5RS RTD Transmitter P.91 B5MS Potentiometer Transmitter P.91 Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1 B Other Two-wire Signal Conditioners Four-wire Signal Conditioners 6-UNIT/ T-UNIT/ B-UNIT Series Two-wire Signal Conditioners Power Transducers Indicators Field-mounted Two-wire Signal Conditioners 6-UNIT Series Field-selectable input, Hockey-puck style Limit Alarms n Field-selectable input types via internal DIP switches Gateway, Remote I/O n Rugged metal housing provides increased noise & RFI protection Paperless Recording System n Outdoor enclosure 6BX-E available PC Recorder Electronic Actuators & Position Sensors Lightning Surge Protectors Super-mini Two-wire Signal Conditioners T-UNIT Series Two-wire Product Selection Guide B3-UNIT Series B5-UNIT Series 6-UNIT Series T-UNIT Series Two-wire Signal Conditioners B6-UNIT Series B-UNIT Series Ultra-high density mounting on wall/DIN rail Space-saving type n Front DIN screw terminals n Wide supply voltage range 12–60V DC n Super-small pneumatic-to-current transducer available 27-UNIT Series 26-UNIT Series Space-saving Two-wire Signal Conditioners n Zero/span adjustments B-UNIT Series 92 Data sheets available on Web in PDF. Visit M-System Data Library at www.m-system.co.jp ISP1-1