When it comes to High Performance look to Dometic HP air conditioners.
Total comfort is the hallmark of these “best in class” air conditioners. You’ll
appreciate that there is no drop in efficiency to achieve this level of luxury.
• 13,500 or 15,000 BTUs
• Lowest power draw in the industry
• Quiet multi-speed blower delivers interior comfort • Most powerful AC/Heat Pump in the industry
• The HP utilizes Dometic’s QuietZone Ducted Air System
for residential performance
• Low profile, stylish ADB
• Eco-friendly 410A refrigerant
High Performance Air Conditioners
The HP provides more cooling comfort with a lower power
draw thanks to a high efficiency compressor, strong fan
motors, blower wheels and large, oversize coils.
Single Zone LCD Thermostat
· Simple, three-button operation
· Easy control including cool/furnace,
heat pump or heat strips
· Low profile
· Manual or automatic control
· Large display screen
Air Distribution Box
· Five multi-directional air slots
· Ratcheting side vents
· Washable Hepa-style filters
· Quick cool air dump feature
Features
Return Air Grill
· Washable filter
· Quick cool air discharge
· Low profile
540315
540316
541915
541916
Nominal capacity, BTU/hr.
13,500
15,000 13,500
15,000
Installation type
Non-ducted or Ducted Non-ducted or Ducted
Ducted
Ducted
Electrical rating
115V AC, 60 Hz, 1Ph
Compressor-rated load amps
12.4
13.3
12.4
13.3
Fan motor-rated load amps
3.0
2.8
3.0
2.8
Compressor-locked rotor amps
63
66
63
66
Fan motor-locked rotor amps
8.5
7.6
8.5
7.6
SCFM, high-speed max./min.
350/275
350/275
350/275
350/275
Heater amps/watts @ 120V AC
13.7/1,530
13.7/1,530
13.7/1,530
13.7/1,530
Refrigerant 410A (oz.)
18.5
29.5
18.5
29.5
Minimum wire size
12 AWG copper up to 24 feet. For distances over 24 feet consult the National Electrical Code.
AC circuit protection
DC circuit protection
(User Supplied) 20 amp time delay fuse or 20 HCAR circuit breaker
(User Supplied) Installation must comply with national, state, provincial and/or local electrical codes
Installed weight, lbs.
91
105
91
105
Minimum generator size - 1 unit
3.5 KW
3.5 KW
3.5 KW
3.5 KW
Minimum generator size - 2 units
5.0 KW
5.0 KW
5.0 KW
5.0 KW
Thermostat/Control options
ADB or
Thermostat
ADB or
Thermostat
Single Zone
LCD
Single Zone LCD
Outstanding Warranty
Dometic’s 2-Year Protection Plus warranty.
For more information visit www.Dometic.com/USA
Dometic reserves the right to make improvements or modifications without notice.
Printed on recycled paper with 25% post consumer content with environmentally safe ink.
Printed in U.S.A.
©2011 Dometic Corporation
OS2258
DRV-648/TM/3-11/1.5M
Download