PVI 3800TL
PVI 5200TL
PVI 6600TL
PVI 7600TL
MEGAWATT SOLAR STATIONS
PVI 14TL
PVI 20TL
PVI 23TL
PVI 28TL
PVI 36TL
PVI 50TL
PVI 60TL
PVI 50KW
PVI 60KW
PVI 75KW
PVI 85KW
PVI 100KW
SGI 225
SGI 250
SGI 266
SGI 300
SGI 500/PE
SGI 500XT
SGI 500XTM
SGI 750XTM
Absolute Maximum Input Voltage
600 VDC
600 VDC
1000 VDC
1000 VDC
600 VDC
600 VDC
600 VDC
1000 VDC
200-950 VDC
300-600 VDC
300-600 VDC
300-600 VDC
545-1000 VDC
300-500 VDC
300-500 VDC
300-500 VDC
545-820 VDC
Operating Input Voltage Range, MPPT
120-550 VDC
180-580 VDC
260-580 VDC
300-900 VDC
240-950 VDC
Full Power Input Voltage Range, MPPT
200-500 VDC
300-540 VDC
300-550 VDC
500-800 VDC
540-800 VDC
480-850 VDC
29 A per MPPT (58 A)
35 A per MPPT (70 A)
36 A per MPPT (108 A)
38 kW (19 kW per MPPT)
54 kW (27 kW per MPPT)
75 kW (25 kW per MPPT)
Full Power Input Voltage Range, MPPT - Low Voltage Option
−
20 A
15 A per MPPT
5.3 kW
3.6 kW per MPPT
Max Operating Input Current - Low Voltage Option
Maximum PV Power
−
20 A per MPPT
25 A per MPPT (50 A)
35 A per MPPT (70 A)
25 A per MPPT (50 A)
4.6 kW per MPPT
5.3 kW per MPPT
19 kW (9.5 kW per MPPT)
27 kW (13.5 kW per MPPT)
31 kW (15.5 kW per MPPT)
−
150 V
Start Voltage - Low Voltage Option
540-850 VDC
−
18 A per MPPT
−
Start Voltage
330 V
−
211 A
−
176 A
185 A
222 A
278 A
314 A
370 A
90 kW (30 kW per MPPT)
65 kW
78 kW
97.5 kW
110.5 kW
130 kW
−
300 V
−
285-500 VDC
38 A per MPPT (114 A)
264 A
299 A
351 A
768 A
853 A
908 A
331.5 kW
325 kW
345.8 kW
−
1026 A
1721/1712 A
1750 A
965 A
390 kW
650kW
650 kW
700 kW
−
330 V
400 V
390 V
−
380 V
−
480 VAC, 3ø+/PE/N
208, 240, 480 or 600 VAC, 3ø+/PE
480 VAC, 3ø+/PE
Dimensions (L x W x H)
Skid
Canopy
Enclosure
1445 A
−
1050 kW
390 V
700 V
Weight
Skid
Canopy
Enclosure
Color
Baseframe
−
Enclosure Type
AC Output
Nominal Output Voltage
208 or 240 VAC, 1ø+/PE
Continuous Output Power
3.3 kW (208 VAC);
3.8 kW (240 VAC)
5 kW (208 VAC);
5.2 kW (240 VAC)
Continuous Output Current
16 A
24 A
Power Factor
208 VAC, 3ø+/PE/N
6.6 kW (208 VAC);
6.6 kW (240 VAC)
6.6 kW (208 VAC);
7.6 kW (240 VAC)
32 A
Unity, > 0.99
480 VAC, 3ø+/PE/N
208 VAC, 3ø+/PE
14 kW
20 kW
23 kW
28 kW
36 kW
50 kW
60 kW
50 kW
60 kW
75 kW
85 kW
100 kW
225 kW
250 kW
266 kW
300 kW
500 kW
39 A
25.5 A
27.7 A
33.7 A
43.5 A
60 A
72 A
139/120/60/48 A
167/144/72/58 A
208/180/90/72 A
236/205/102/82 A
278/240/120/96 A
271 A
301/240 A
320 A
360 A
602 A
Unity, >0.99 (adjustable
0.8 leading / 0.8 lagging)
Unity, >0.99 (adjustable
0.9 leading / 0.9 lagging)
Unity, >0.99 (adjustable 0.8 leading / 0.8 lagging)
Unity, >0.99 (adjustable 0.8 leading / 0.8 lagging)
Adjustable 0.9 leading / 0.9 lagging, factory set at 1
380 VAC, 3ø+/PE
Peak Efficiency (208/240/480/600 VAC)
98.3%
96.6%
97.4%
CEC Efficiency (208/240/480 VAC)
97.5%
96.0%
97.0%
Tare Loss
<2W
4W
Ambient Temperature Range (full power)
-13°F to +122°F (-25°C to +50°C)
Storage Temperature Range
-40°F to +185°F (-40°C to +85°C)
Audible Noise
98.6%
CSA
99.0%
98.0%
Integrated string combiner:
2 strings per tracker
(1 tracker)
Transformer
AC/DC Disconnect
Enclosure Rating
Enclosure Finish & Material
500 kW
SolrenView Monitoring Service
1387 A
Adjustable 0.9 leading / 0.9 lagging, factory set at 1
760 A
98.5%
96.7/97.7/96.5/96.5%
96.7/97.8/96.5/96.5%
96.0/97.0/96.0%
97.3/97.1/97.2/97.2%
96.6/96.7/96.9/96.9%
97.0/96.0/97.0%
96.5/96.9/96.9/96.9%
96.0/96.0/96.5%
98.0%
97.9%/98.3%
97.5%
97.0%/97.5%
28 W
32 W
98.1%
98.3%
98.0%
Door (Enclosure)
Minimum 20 gauge hollow metal doors with
R2.4 insulation; interior panic hardware;
door closer; exterior drip strips
Minimum 20 gauge hollow metal doors with R2.4 insulation;
interior panic hardware; door closer; exterior drip strips
Interior florescent lighting;
4 ft or 8 ft T8 high output light
fixtures; other light fixtures available
Interior florescent lighting;
4 ft or 8 ft T8 high output light fixtures; other light fixtures available
Electrical metallic tubing (EMT) or
flexible metal conduit; not less than 1/2” diameter
Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2” diameter
20 A, 250 V minimum (located at doors)
20 A, 250 V minimum (located at doors)
Convenience Power
120 V, 20 A receptacles, listed
GFCI weather tight & approved for outdoor use
120 V, 20 A receptacles, listed GFCI weather tight & approved for outdoor use
Wireways & Cables
All MSS components are listed and station is in full
compliance with the National Electric Code (NEC)
All MSS components are listed and station is in full compliance with the National Electric Code (NEC)
-40°F to +158°F (-40°C to +70°C)
-40°F to +122°F (-40°C to +50°C)
Lighting (Enclosure)
< 50 dBA @ 3 m
< 55 dBA @ 1 m
< 62 dBA @ 3 m
< 60 dBA @ 5 m
UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B
UL 1741:2010, UL 1699B, CSA-C22.2 NO.107.1-01,
IEEE1547; FCC part 15
UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B
UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B
CSA
ETL
ETL
Conduit & Fittings
Light Switches (Enclosure)
ETL
Integrated string combiner: 2 strings per tracker (2 trackers)
Integrated string combiner: 4 strings per tracker (2 trackers), 15 A (fused by-pass available)
Integrated string combiner:
5 strings per tracker
(2 trackers), 15 or 30 A* (30 A
only for combined inputs)
Integrated string combiner: 5 strings per tracker
(3 trackers), 15-30 A
(25 or 30 A only for combined inputs)
Subcombiner: Fuses or breakers, 2-8 positions, 40-300 A*
Subcombiner: Fuses or breakers, 6-24 positions, 70-400 A*
Subcombiner:
Fuses or breakers,
8-32 positions, 70-400 A*
Subcombiner:
Fuses or breakers,
8-32 positions, 70-400 A*
Subcombiner: Fuses, 4 to 16 positions, 100-400 A*
Subcombiner: Breakers, 4 to 15 positions, 125-350 A*
Transformerless
Transformerless
Transformerless
Standard, fully-integrated
Standard, fully-integrated
Dedicated external transformer required, refer to external transformer specifications
DC disconnect, fully-integrated
Standard, fully-integrated
Standard, fully-integrated
Standard, fully-integrated
Standard, Fully-integrated
DC disconnect: standard, fully-integrated;
AC disconnect/breaker: optional disconnect, breaker or breaker with shunt trip
39.4 x 23.6 x 10.24 in. (1,000 x 600 x 260 mm)
Side Facing: 78.2 x 50-53 x 33 in. (1,987 x 1,270-1,347 x 839 mm) (width dependent upon rating of disconnect chosen)
Forward Facing: 78.2 x 79-88 x 33 in. (1,987 x 2,007-2,236 x 839 mm) (width dependent upon rating of disconnect chosen)
17.5 x 15.8 x 8.5 in.
(445 x 402 x 216 mm)
26.8 x 15.8 x 8.5 in. (681 x 402 x 216 mm) (including DC disconnect)
43 lbs (19.5 kg)
65 lbs (29.5 kg)
Type 4 + Salt Mist Corrosion Protection
Aluminum
41.6 x 21.4 x 8.5 in. (1,057 x 544 x 216 mm)
141 lbs (64 kg)
39.4 x 23.6 x 9.1 in. (1,001 x 600 x 232 mm)
Inverter: 104 lbs (47.2 kg);
Wiring Box: 22 lbs (9.9 kg)
132 lbs (60 kg)
Type 4
Polyester powder coated aluminum
Inverter: 121 lbs (55 kg);
Wiring Box: 22 lbs (9.9 kg)
Inverter: 123.5 lbs (56 kg);
Wiring Box: 33 lbs (15 kg)
Type 4X
Type 4X
Polyester powder coated aluminum
1,450 lbs (658 kg)
1,875 lbs (851 kg)
79 x 109 x 41 in. (2,007 x 2,769 x 1,042 mm)
5,170 lbs (2,346 kg)
5,650 lbs (2563 kg)
Type 3R
Polyester powder coated steel; Optional 316 stainless steel
6,980 lbs (3,167 kg);
PE Model: 7,107 lbs (3,224 kg)
3,410 lbs (1,547 kg)
Type 3R
3,080 lbs (1,398 kg)
Nominal Output Power
Polyester powder coated steel; Optional 316 stainless steel
Utility Connection kV Classes
Optional, External
Standard, Internal
Standard, Integrated
Standard, Integrated
Standard, Integrated
Optional
Optional
Optional
Optional
Optional
Optional
Optional, External
Optional, External
Optional, External
Optional, External
400 A
800 A
1600 A
Sub-Array Monitoring (DC Current)
−
−
−
Optional, 2-8 zones
Optional, 6 zones
Optional, 8 zones
Optional, 8 zones
800 A
Cellular Communication
−
−
−
Optional, SolrenView AIR
Optional, SolrenView AIR
Optional, SolrenView AIR
Communication Interface
RS-485
RS-485 Modbus RTU
RS-485 Modbus RTU
RS-485 SunSpec Modbus RTU
RS-485 SunSpec Modbus RTU
RS-485 SunSpec Modbus RTU
Standard
10 year
10 year
10 year
5 year
5 year
5 year
Optional
Extended warranty not available
15, 20 year; extended service agreement
15, 20 year; extended service agreement
10, 15, 20 year; extended service agreement; uptime guarantee
10, 15, 20 year; extended service agreement; uptime guarantee
10, 15, 20 year; extended service agreement; uptime guarantee
Warranty
750 kVA, 3-Ph
1000 kVA, 3-Ph
2.5-35 kV
15 kV / 25 kV / 35 kV
15 kV / 25 kV / 35 kV
(2) 2.5% above & (2) below nominal
(2) 2.5% above & (2) below nominal
60 Hz
60 Hz
380 VAC
Inverter Output kV Class
1.2 kV
1.2 kV
Cooling Class
KNAN
KNAN
Envirotemp FR3
Envirotemp FR3
Partial range current-limiting fuses
Partial range current-limiting fuses
Dead front and loop feed
Dead front and loop feed
Configuration
1600 A
500 kVA, 3-Ph
208 VAC
Overcurrent Protection
Optional, 1 zone per protected input (up to 16 zones)
1000 kVA, 3-Ph
2.5-35 kV
Inverter Output Voltage
Insulating Fluid
Optional, External
500 kVA, 3-Ph
Utility Connection Voltage
Frequency
3,570 lbs (1,620 kg)
Type 3R
Polyester powder coated steel; Optional 316 stainless steel
Medium Voltage Transformer*
Taps
82 x 109 x 41 in. (2,083 mm x 2,769 mm x 1,042 mm)
Structural steel; conforms to ASTM A36; shop welded
Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional;
bows are c-style 16 gauge galvanized at 24”; sloped at 1” minimum pitch; insulation optional
-40°F to +131°F (-40°C to +55°C)
CSA
Frisco White; other colors optional
Structural steel;
conforms to ASTM A36; shop welded
Full length, tight fitted, weather tight &
weather proof; EPDM membrane roof optional;
bows are c-style 16 gauge galvanized at 24”;
sloped at 1” minimum pitch; insulation optional
-40°F to +158°F (-40°C to +70°C)
ETL
Frisco White; other colors optional
45,000 lbs (20,412 kg)
46,500 lbs (21,092 kg)
47,000 lbs (21,319 kg)
Roof (Enclosure)
Electrical
UL 1741/IEEE 1547, CSA C22.2#107.1
40,000 lbs (18,144 kg)
41,500 lbs (18,824 kg)
42,000 lbs (19,051 kg)
Full length, tight fitted, weather tight & weather proof;
standard 0.040 gauge factory painted stucco aluminum
-40°F to +122°F (-40°C to +50°C)
< 67 dBA @ 10 m
37,500 lbs (17,010 kg)
39,500 lbs (17,917 kg)
39,500 lbs (17,917 kg)
Full length, tight fitted, weather tight &
weather proof; standard 0.040 gauge
factory painted stucco aluminum
-40°F to +122°F (-40°C to +50°C)
< 58 dBA @ 3 m
35,000 lbs (15,876 kg)
36,500 lbs (16,556 kg)
37,000 lbs (16,783 kg)
Siding (Enclosure)
-40°F to +131°F (-40°C to +55°C)
-40°F to +158°F
(-40°C to +70°C)
123 W
33,000 lbs (14,969 kg)
34,500 lbs (15,649 kg)
39,000 lbs (17,690 kg)
Post minimum 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket
-22°F to +140°F (-30°C to +60°C)
Derating occurs over +122°F (+50°C)
-22°F to +158°F (-30°C to +70°C)
89 W
30,000 lbs (13,608 kg)
31,500 lbs (14,288 kg)
36,000 lbs (16,330 kg)
267 x 138 x 95 in. (6,782 x 3,506 x 2,413 mm)
267 x 138 x 129 in. (6,782 x 3,506 x 3,277 mm)
410 x 138 x 120 in. (10,414 x 3,506 x 3,048 mm)
Post minimum 14 gauge galvanized, shop welded
to structural steel base frame & roof z-bracket
<3W
-22°F to +140°F (-30°C to +60°C)
Derating occurs over +45°C
41 W
267 x 138 x 95 in. (6,782 x 3,506 x 2,413 mm)
267 x 138 x 129 in. (6,782 x 3,506 x 3,277 mm)
410 x 138 x 120 in. (10,414 x 3,506 x 3,048 mm)
Walls (Enclosure)
1140 A
Adjustable 0.8 leading / 0.8 lagging, factory set at 1
Revenue Grade Meter/Monitoring
*Please see combiner datasheet for complete subcombiner details
MSS 1.5MW-XTM
1/4” steel plate or 3/16” diamond tread steel plate; insulation optional
Flooring (Enclosure)
750 kW
Communications
Data Logger Hardware
MSS 1MW-XTM
Skid, Canopy or Enclosure
Mechanical
Weight
MSS 0.75MW-XTM
Skid, Canopy or Enclosure
< 2W
-13°F to +140°F (-25°C to +60°C)
Derating occurs over +50°C
UL 1741/IEEE 1547, UL 1699B, CSA C22.2#107.1, FCC part 15 A&B
Certification Agency
98.5%
2W
< 45 dBA @ 3 m
Safety Listings & Certifications
Dimensions (H x W x D)
MSS 0.5MW-XTM
1/4” steel plate or 3/16” diamond
tread steel plate; insulation optional
Performance
Subcombiner or Integrated String Combiner
MSS 1MW-XT
Structural
DC Input
Maximum Operating Input Current
MSS 0.5MW-XT
*Transformer options not listed, but may be quoted upon request
1500 kVA, 3-Ph
COMBINERS
DISCONNECTING COMBINERS
RESIDENTIAL RAPID
SHUTDOWN COMBINER
AFDI COMBINER
MONITORING
PERFORMANCE
Market leading performance: industry leading
CEC efficiencies and proven +99.5% uptime.
Over 100 years in the power electronics and
PV inverter industries with 23M inverters
installed worldwide.
Specifications
Number of Fused
Inputs
DISCOM
DISCOM 1500
ARCCOM
8, 12, 16, 20, 24LT, 24, 30
8, 10, 12, 14,
15, 16, 18, 20, 21, 24
8, 12, 16, 24
Input Wire Range
14-6 AWG
12-8 AWG
Max Output Wire Size*
8
10
12
Mech Lug: 350 kcmil, or (2) 300 kcmil
Compression Lug: 600 kcmil
-
600 kcmil or 750 kcmil
600 kcmil or 750 kcmil
600 kcmil
-
600 kcmil or 750 kcmil
14
Mech Lug: 350 kcmil, or (2) 300 kcmil
Compression Lug: 600 kcmil
-
600 kcmil or 750 kcmil
-
15
-
600 kcmil or 750 kcmil
-
16
18
20
21
24LT
24
30
Maximum Voltage
Maximum Current
Fuse Range
Operating Temperature
Mounting Locations
600 kcmil
Enclosure Rating
Enclosure
Operating Temperature
Mounting Locations
600 kcmil or 750 kcmil
-
600 kcmil or 750 kcmil
-
Standard
Mech Lug: (2) 600 kcmil
Compression Lug: 600 or 750 kcmil
Mech Lug: (2) 600 kcmil
Compression Lug: 600 or 750 kcmil
Mech Lug: (2) 600 kcmil
Compression Lug: 600 or 750 kcmil
-
-
Enclosure
600 kcmil or 750 kcmil
600 kcmil
-
-
Safety Listings &
Certifications
Certification Agency
Weight
Enclosure Rating
600 or 1000 VDC
1500 VDC
600 or 1000 VDC
96, 144, 192, 240, 250, 288, 360 A
96, 120, 144, 168, 180, 192,
216, 240, 252, 282 A
96, 144, 192, 288 A
4 A, 6 A, 8 A, 10 A, 12 A, 15 A
15 A, 25 A, 30 A
4 A, 6 A, 8 A, 10 A, 12 A, 15 A
Enclosure
2 positions per MPPT
RELIABILITY
DC powered by the array (2.5 W)
All inverters are designed and tested to the
15 A included, 20 A maximum
highest standards including HALT, field testing
-40°F to +158°F
(-40°C to +70°C)
UL 1741, CSA C22.2#107.1
CSA
10 year
SERVICEABILITY
Technicians and offices strategically located
throughout the U.S.A. and internationally. All
minimal downtime.
Aluminum
PVI 3800-7600TL
*Dimensions do not include DC input wiring shown in photos; input
wiring is included when RSD is ordered
EXPERIENCE
Thousands of PV projects ranging in size from
UL 1741, CSA C22.2#107.1
UL 1741,
CSA C22.2#107.1, UL 1699B
partners with PV project owners, investors,
ETL
ETL
inverter solutions. Yaskawa - Solectria Solar
developers, EPCs, and distributors throughout
the world to build high-performing PV systems,
20/24/30 x 16/20/24 x 6/6/8 in.
30 x 24 x 8 in.
(962 x 610 x 203 mm)
-
(508/610/762 x 406/508/610 x 203/203/203 mm)
20/24/30 x 16/20/24 x 8/8/8 in.
30 x 24 x 8 in.
(962 x 610 x 203 mm)
29/36/75 lbs (13.2/16.3/34 kg)
29/36/75 lbs (13.2/16.3/34 kg)
26/29.3/56 lbs (11.8/13.3/25.4 kg)
75 lbs (34 kg)
56 lbs (25.4 kg)
Type 4; Optional Type 4X
Polyester powder coated steel;
optional 316 stainless steel or
fiberglass
Polyester powder coated steel;
optional fiberglass
24 x 20 x 7 in.
(610 x 508 x 178 mm)
24 x 20 x 7 in.
(610 x 508 x 178 mm)
24 x 20 x 7 in.
(610 x 508 x 178 mm)
42/43/44 lbs (19/19.5/20 kg)
42/43/44 lbs (19/19.5/20 kg)
35.3/36.3/37.3 lbs (16/16.5/17 kg)
Type 4; Optional Type 4X
Polyester powder coated steel;
optional 316 stainless steel or
fiberglass
SolrenView Inverter Direct standard animated view
The PVI 14-60TL are compact, three-phase transformerless string
inverters designed to maximize reliability and efficiency, while
SolrenView GlobalView simplifying installation. The PVI 50-100KW, SGI 225-500PE,
GlobalView provides users with the ability to view, sort and search all of their sites monitored by SolrenView. GlobalView is available upon request and
simplifies the process of monitoring the performance of multiple sites. It provides one web-based site where users will find site performance details including
real-time AC power performance and lifetime power production of all sites combined.
and SGI 500XT inverters are time tested, proven solutions for
600VDC applications in both new PV plants and for legacy inverter
SolrenView Revenue Grade Energy Production replacement.
available upon request
optional monitoring package
SolrenView Revenue Grade Energy Production Monitoring package option keeps track of lifetime energy produced by a customer’s PV system. This package
option also includes e-mail and cell phone alerts with detailed descriptions of system problems and a recommended course of action. Compatible with thirdparty inverters.
UTILITY-SCALE INVERTERS
SolrenView SolZone DC Current Sub-Array Monitoring optional
SolZone provides an extra level of granularity to see multiple sub-array DC currents. SolZone has the ability to compare individual PV zones against each other
based on the number of sub-array fuses or ‘zones’ built into a Yaskawa - Solectria Solar factory-installed DC subcombiner. Additional inverter hardware is
required for SolZone. This package option also includes e-mail and cell phone alerts with detailed descriptions of system problems and a recommended course
of action. SolZone is compatible with most third-party monitoring systems.
The SGI XTM inverter series is a line of external transformer inverters
designed for direct to medium voltage applications. These inverters
have redundant power stages, which optimize reliability and energy
harvest. They also include the latest evolution of central inverter
SolrenView Agency Reportingoptional
technologies proven over the last decade. Advanced Smart Grid
SolrenView Agency Reporting is for customers that require a revenue grade energy production report to be sent to an agency such as NEPOOL, WREGIS,
MassCEC, PG&E, SCE, CCSE, IID, or PaCE. A report is generated from SolrenView Revenue Grade metering outputs and sent directly to the agency of your choice.
Yaskawa - Solectria Solar’s monitoring team works directly with agencies to activate and maintain solar production credit accounts.
features are available for utility applications.
from residential rooftops to the world’s largest
CPV plant.
standard monitoring package
SolrenView Inverter Direct monitoring allows customers to see detailed operational inverter data (DC and AC) using a web enabled device. This standard
package allows customers to view daily, weekly, monthly, and annual graphs up to 5 years into the past, viewing single events or long term performance trends.
The package includes e-mail and cell phone alerts with detailed descriptions of system issues and a recommended course of action.
The Kiosk View (Animated View) provides customers with a quick and easy access to a customer’s PV system performance. This is a great tool for advertising
and public viewing. When the “Animated View” button is clicked on the SolrenView screen, SolrenView will continuously loop through the site overview,
environmental footprint, project details, site analytics, and if applicable, the detailed analytics page.
Type 4X
1kW to 30MW rely on Yaskawa - Solectria Solar
20/24/30 x 16/20/24 x 6/6/8 in.
SIMPLIFYING SOLAR
6.6 lbs (3 kg)
Indoor, Outdoor, Wall, Array,
Rooftop - Vertical or Horizontal
5 year
right choice for large commercial and utility-scale projects.
COMMERCIAL INVERTERS
Indoor, Outdoor, Wall, Array, Rooftop - Vertical, Horizontal or Angled
8-12 / 16 / 24
technology from reliable partners. Yaskawa - Solectria Solar is the
SolrenView monitoring provides PV system owners with a highly accurate and real time webbased monitoring solution to maximize efficiency and profitability of their solar assets. Yaskawa Solectria Solar’s SolrenView web-based monitoring solution is available for use with residential,
commercial, and utility-scale inverters, allowing for real-time, seamless recording and reporting
of PV system production. The integrated SolrenView data logger is available for all 3-phase
central inverters. A standalone SolrenView data logger is available for Solectria’s PVI 38007600TLs and PVI 14-60TLs. The complete SolrenView system features inverter direct monitoring,
revenue grade monitoring, agency reporting, SolZone™ sub-array current monitoring, XML feed,
kiosk view and weather station.
SolrenView Kiosk View inverters are designed for easy service and
12.4 x 10 x 2.2 in
(315 x 254 x 56 mm)*
PRODUCT
SPECIFICATIONS
Solar power is reaching cost parity with conventional energy sources
and a rigorous design review process.
Indoor, Outdoor, Wall,
Array, Rooftop
- Vertical, Horizontal or Angled
-40°F to +122°F (-40°C to +50°C)
5 year
class warranties.
and project portfolios. Those that will be successful need the best
-40°F to +122°F (-40°C to +50°C)
8-12 / 16-20 / 24LT-30
solutions supported by exceptional engineering talent and world
15 A included, 20 A maximum
Compatibility
Compatible Products
Solar offers a versatile line of high-efficiency and high-value inverter
in North America, driving aggressive demand for large solar projects
Warranty
Dimensions (H x W x D)
manufacturer based in Lawrence, Massachusetts. Yaskawa - Solectria
600 VDC
Certifications
Mech Lug: (2) 600 kcmil
Compression Lug: 600 kcmil
-
(508/610/762 x 406/508/610 x 152/152/203 mm)
Weight
Powder Coated Steel
316 Stainless Steel
Fiberglass
Fuse Range
-
(508/610/762 x 406/508/610 x 152/152/203 mm)
Fiberglass
Integrated Power Supply
600 kcmil or 750 kcmil
Standard
316 Stainless Steel
Integrated String
Combiner
600 kcmil
Warranty
Dimensions (H x W x D)
Powder Coated Steel
PV Fuse Size
600 kcmil or 750 kcmil
Certification Agency
Enclosure
Maximum Open Circuit
Voltage
Mech Lug: (2) 600 kcmil
Compression Lug: 600 kcmil
-
Certifications
Safety Listings &
Certifications
Specifications
SolrenView™ Web-Based PV Monitoring
Yaskawa - Solectria Solar is a leading grid-tied PV inverter
SolrenView Weather Stationoptional
SolrenView Weather Station is a real-time weather package which allows customers to view accurate readings of crucial environmental information that may
affect the performance of your PV system. The weather station comes standard with a solar irradiance sensor as well as temperature sensors for ambient and
module measurements. Wind speed and direction sensors are additional options that may be added to the weather station. The weather station is a great
educational tool and a must-have for PPAs. Complies with RS-485 SunSpec Environmental Sensor System.
MEGAWATT SOLUTIONS
Yaskawa - Solectria Solar offers a variety of fully-integrated MW
solutions for both string and central inverters. The Decentralized
MW Solution includes all major system components for connecting
string inverters to medium voltage (inverters, panelboards,
switchboards, and transformers). Megawatt Solar Stations (MSS)
Viewable Measurements:
- Solar Irradiance
- Ambient Temperature
- Module Temperature
- Wind Speed and Wind Direction (option)
SolrenView AIRoptional
connect central inverters to a medium voltage transformer as a part
The SolrenView AIR option permits customers to take advantage of SolrenView web-based monitoring features via a fully-integrated 4G cellular modem when
standard internet access is not available at a site. SolrenView AIR may be factory integrated for any inverter 50kW and greater (PVI 50-100KW, SGI 225-500PE,
SGI 500XT, SGI 500/750XTM inverters; not available for PVI 3800-7600TL or PVI 14-60TL inverters).
of a prefabricated skid.
*See product datasheet on www.solectria.com/documentation for full Output Wire Ranges
SolrenView XML Feedoptional
YASKAWA – SOLECTRIA SOLAR
INVERTERS@SOLECTRIA.COM
SOLECTRIA.COM
+1 978-683-9700
360 MERRIMACK STREET
LAWRENCE, MA 01843
DOCR-070256-G
© 2016 YASKAWA – SOLECTRIA SOLAR
SolrenView XML feed option provides a reporting framework for customers with a need to display real-time monitoring information about their PV system within
their applications/website or using third-party monitoring.
Download