GRID-TIED PV INVERTER OVERVIEW PVI 3800TL PVI 5200TL PVI 6600TL PVI 7600TL MEGAWATT SOLAR STATIONS PVI 14TL PVI 20TL PVI 23TL PVI 28TL PVI 36TL PVI 50TL PVI 60TL PVI 50KW PVI 60KW PVI 75KW PVI 85KW PVI 100KW SGI 225 SGI 250 SGI 266 SGI 300 SGI 500/PE SGI 500XT SGI 500XTM SGI 750XTM Absolute Maximum Input Voltage 600 VDC 600 VDC 1000 VDC 1000 VDC 600 VDC 600 VDC 600 VDC 1000 VDC 200-950 VDC 300-600 VDC 300-600 VDC 300-600 VDC 545-1000 VDC 300-500 VDC 300-500 VDC 300-500 VDC 545-820 VDC Operating Input Voltage Range, MPPT 120-550 VDC 180-580 VDC 260-580 VDC 300-900 VDC 240-950 VDC Full Power Input Voltage Range, MPPT 200-500 VDC 300-540 VDC 300-550 VDC 500-800 VDC 540-800 VDC 480-850 VDC 29 A per MPPT (58 A) 35 A per MPPT (70 A) 36 A per MPPT (108 A) 38 kW (19 kW per MPPT) 54 kW (27 kW per MPPT) 75 kW (25 kW per MPPT) Full Power Input Voltage Range, MPPT - Low Voltage Option − 20 A 15 A per MPPT 5.3 kW 3.6 kW per MPPT Max Operating Input Current - Low Voltage Option Maximum PV Power − 20 A per MPPT 25 A per MPPT (50 A) 35 A per MPPT (70 A) 25 A per MPPT (50 A) 4.6 kW per MPPT 5.3 kW per MPPT 19 kW (9.5 kW per MPPT) 27 kW (13.5 kW per MPPT) 31 kW (15.5 kW per MPPT) − 150 V Start Voltage - Low Voltage Option 540-850 VDC − 18 A per MPPT − Start Voltage 330 V − 211 A − 176 A 185 A 222 A 278 A 314 A 370 A 90 kW (30 kW per MPPT) 65 kW 78 kW 97.5 kW 110.5 kW 130 kW − 300 V − 285-500 VDC 38 A per MPPT (114 A) 264 A 299 A 351 A 768 A 853 A 908 A 331.5 kW 325 kW 345.8 kW − 1026 A 1721/1712 A 1750 A 965 A 390 kW 650kW 650 kW 700 kW − 330 V 400 V 390 V − 380 V − 480 VAC, 3ø+/PE/N 208, 240, 480 or 600 VAC, 3ø+/PE 480 VAC, 3ø+/PE Dimensions (L x W x H) Skid Canopy Enclosure 1445 A − 1050 kW 390 V 700 V Weight Skid Canopy Enclosure Color Baseframe − Enclosure Type AC Output Nominal Output Voltage 208 or 240 VAC, 1ø+/PE Continuous Output Power 3.3 kW (208 VAC); 3.8 kW (240 VAC) 5 kW (208 VAC); 5.2 kW (240 VAC) Continuous Output Current 16 A 24 A Power Factor 208 VAC, 3ø+/PE/N 6.6 kW (208 VAC); 6.6 kW (240 VAC) 6.6 kW (208 VAC); 7.6 kW (240 VAC) 32 A Unity, > 0.99 480 VAC, 3ø+/PE/N 208 VAC, 3ø+/PE 14 kW 20 kW 23 kW 28 kW 36 kW 50 kW 60 kW 50 kW 60 kW 75 kW 85 kW 100 kW 225 kW 250 kW 266 kW 300 kW 500 kW 39 A 25.5 A 27.7 A 33.7 A 43.5 A 60 A 72 A 139/120/60/48 A 167/144/72/58 A 208/180/90/72 A 236/205/102/82 A 278/240/120/96 A 271 A 301/240 A 320 A 360 A 602 A Unity, >0.99 (adjustable 0.8 leading / 0.8 lagging) Unity, >0.99 (adjustable 0.9 leading / 0.9 lagging) Unity, >0.99 (adjustable 0.8 leading / 0.8 lagging) Unity, >0.99 (adjustable 0.8 leading / 0.8 lagging) Adjustable 0.9 leading / 0.9 lagging, factory set at 1 380 VAC, 3ø+/PE Peak Efficiency (208/240/480/600 VAC) 98.3% 96.6% 97.4% CEC Efficiency (208/240/480 VAC) 97.5% 96.0% 97.0% Tare Loss <2W 4W Ambient Temperature Range (full power) -13°F to +122°F (-25°C to +50°C) Storage Temperature Range -40°F to +185°F (-40°C to +85°C) Audible Noise 98.6% CSA 99.0% 98.0% Integrated string combiner: 2 strings per tracker (1 tracker) Transformer AC/DC Disconnect Enclosure Rating Enclosure Finish & Material 500 kW SolrenView Monitoring Service 1387 A Adjustable 0.9 leading / 0.9 lagging, factory set at 1 760 A 98.5% 96.7/97.7/96.5/96.5% 96.7/97.8/96.5/96.5% 96.0/97.0/96.0% 97.3/97.1/97.2/97.2% 96.6/96.7/96.9/96.9% 97.0/96.0/97.0% 96.5/96.9/96.9/96.9% 96.0/96.0/96.5% 98.0% 97.9%/98.3% 97.5% 97.0%/97.5% 28 W 32 W 98.1% 98.3% 98.0% Door (Enclosure) Minimum 20 gauge hollow metal doors with R2.4 insulation; interior panic hardware; door closer; exterior drip strips Minimum 20 gauge hollow metal doors with R2.4 insulation; interior panic hardware; door closer; exterior drip strips Interior florescent lighting; 4 ft or 8 ft T8 high output light fixtures; other light fixtures available Interior florescent lighting; 4 ft or 8 ft T8 high output light fixtures; other light fixtures available Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2” diameter Electrical metallic tubing (EMT) or flexible metal conduit; not less than 1/2” diameter 20 A, 250 V minimum (located at doors) 20 A, 250 V minimum (located at doors) Convenience Power 120 V, 20 A receptacles, listed GFCI weather tight & approved for outdoor use 120 V, 20 A receptacles, listed GFCI weather tight & approved for outdoor use Wireways & Cables All MSS components are listed and station is in full compliance with the National Electric Code (NEC) All MSS components are listed and station is in full compliance with the National Electric Code (NEC) -40°F to +158°F (-40°C to +70°C) -40°F to +122°F (-40°C to +50°C) Lighting (Enclosure) < 50 dBA @ 3 m < 55 dBA @ 1 m < 62 dBA @ 3 m < 60 dBA @ 5 m UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741:2010, UL 1699B, CSA-C22.2 NO.107.1-01, IEEE1547; FCC part 15 UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B UL 1741/IEEE 1547, CSA C22.2#107.1, FCC part 15B CSA ETL ETL Conduit & Fittings Light Switches (Enclosure) ETL Integrated string combiner: 2 strings per tracker (2 trackers) Integrated string combiner: 4 strings per tracker (2 trackers), 15 A (fused by-pass available) Integrated string combiner: 5 strings per tracker (2 trackers), 15 or 30 A* (30 A only for combined inputs) Integrated string combiner: 5 strings per tracker (3 trackers), 15-30 A (25 or 30 A only for combined inputs) Subcombiner: Fuses or breakers, 2-8 positions, 40-300 A* Subcombiner: Fuses or breakers, 6-24 positions, 70-400 A* Subcombiner: Fuses or breakers, 8-32 positions, 70-400 A* Subcombiner: Fuses or breakers, 8-32 positions, 70-400 A* Subcombiner: Fuses, 4 to 16 positions, 100-400 A* Subcombiner: Breakers, 4 to 15 positions, 125-350 A* Transformerless Transformerless Transformerless Standard, fully-integrated Standard, fully-integrated Dedicated external transformer required, refer to external transformer specifications DC disconnect, fully-integrated Standard, fully-integrated Standard, fully-integrated Standard, fully-integrated Standard, Fully-integrated DC disconnect: standard, fully-integrated; AC disconnect/breaker: optional disconnect, breaker or breaker with shunt trip 39.4 x 23.6 x 10.24 in. (1,000 x 600 x 260 mm) Side Facing: 78.2 x 50-53 x 33 in. (1,987 x 1,270-1,347 x 839 mm) (width dependent upon rating of disconnect chosen) Forward Facing: 78.2 x 79-88 x 33 in. (1,987 x 2,007-2,236 x 839 mm) (width dependent upon rating of disconnect chosen) 17.5 x 15.8 x 8.5 in. (445 x 402 x 216 mm) 26.8 x 15.8 x 8.5 in. (681 x 402 x 216 mm) (including DC disconnect) 43 lbs (19.5 kg) 65 lbs (29.5 kg) Type 4 + Salt Mist Corrosion Protection Aluminum 41.6 x 21.4 x 8.5 in. (1,057 x 544 x 216 mm) 141 lbs (64 kg) 39.4 x 23.6 x 9.1 in. (1,001 x 600 x 232 mm) Inverter: 104 lbs (47.2 kg); Wiring Box: 22 lbs (9.9 kg) 132 lbs (60 kg) Type 4 Polyester powder coated aluminum Inverter: 121 lbs (55 kg); Wiring Box: 22 lbs (9.9 kg) Inverter: 123.5 lbs (56 kg); Wiring Box: 33 lbs (15 kg) Type 4X Type 4X Polyester powder coated aluminum 1,450 lbs (658 kg) 1,875 lbs (851 kg) 79 x 109 x 41 in. (2,007 x 2,769 x 1,042 mm) 5,170 lbs (2,346 kg) 5,650 lbs (2563 kg) Type 3R Polyester powder coated steel; Optional 316 stainless steel 6,980 lbs (3,167 kg); PE Model: 7,107 lbs (3,224 kg) 3,410 lbs (1,547 kg) Type 3R 3,080 lbs (1,398 kg) Nominal Output Power Polyester powder coated steel; Optional 316 stainless steel Utility Connection kV Classes Optional, External Standard, Internal Standard, Integrated Standard, Integrated Standard, Integrated Optional Optional Optional Optional Optional Optional Optional, External Optional, External Optional, External Optional, External 400 A 800 A 1600 A Sub-Array Monitoring (DC Current) − − − Optional, 2-8 zones Optional, 6 zones Optional, 8 zones Optional, 8 zones 800 A Cellular Communication − − − Optional, SolrenView AIR Optional, SolrenView AIR Optional, SolrenView AIR Communication Interface RS-485 RS-485 Modbus RTU RS-485 Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU RS-485 SunSpec Modbus RTU Standard 10 year 10 year 10 year 5 year 5 year 5 year Optional Extended warranty not available 15, 20 year; extended service agreement 15, 20 year; extended service agreement 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee 10, 15, 20 year; extended service agreement; uptime guarantee Warranty 750 kVA, 3-Ph 1000 kVA, 3-Ph 2.5-35 kV 15 kV / 25 kV / 35 kV 15 kV / 25 kV / 35 kV (2) 2.5% above & (2) below nominal (2) 2.5% above & (2) below nominal 60 Hz 60 Hz 380 VAC Inverter Output kV Class 1.2 kV 1.2 kV Cooling Class KNAN KNAN Envirotemp FR3 Envirotemp FR3 Partial range current-limiting fuses Partial range current-limiting fuses Dead front and loop feed Dead front and loop feed Configuration 1600 A 500 kVA, 3-Ph 208 VAC Overcurrent Protection Optional, 1 zone per protected input (up to 16 zones) 1000 kVA, 3-Ph 2.5-35 kV Inverter Output Voltage Insulating Fluid Optional, External 500 kVA, 3-Ph Utility Connection Voltage Frequency 3,570 lbs (1,620 kg) Type 3R Polyester powder coated steel; Optional 316 stainless steel Medium Voltage Transformer* Taps 82 x 109 x 41 in. (2,083 mm x 2,769 mm x 1,042 mm) Structural steel; conforms to ASTM A36; shop welded Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional; bows are c-style 16 gauge galvanized at 24”; sloped at 1” minimum pitch; insulation optional -40°F to +131°F (-40°C to +55°C) CSA Frisco White; other colors optional Structural steel; conforms to ASTM A36; shop welded Full length, tight fitted, weather tight & weather proof; EPDM membrane roof optional; bows are c-style 16 gauge galvanized at 24”; sloped at 1” minimum pitch; insulation optional -40°F to +158°F (-40°C to +70°C) ETL Frisco White; other colors optional 45,000 lbs (20,412 kg) 46,500 lbs (21,092 kg) 47,000 lbs (21,319 kg) Roof (Enclosure) Electrical UL 1741/IEEE 1547, CSA C22.2#107.1 40,000 lbs (18,144 kg) 41,500 lbs (18,824 kg) 42,000 lbs (19,051 kg) Full length, tight fitted, weather tight & weather proof; standard 0.040 gauge factory painted stucco aluminum -40°F to +122°F (-40°C to +50°C) < 67 dBA @ 10 m 37,500 lbs (17,010 kg) 39,500 lbs (17,917 kg) 39,500 lbs (17,917 kg) Full length, tight fitted, weather tight & weather proof; standard 0.040 gauge factory painted stucco aluminum -40°F to +122°F (-40°C to +50°C) < 58 dBA @ 3 m 35,000 lbs (15,876 kg) 36,500 lbs (16,556 kg) 37,000 lbs (16,783 kg) Siding (Enclosure) -40°F to +131°F (-40°C to +55°C) -40°F to +158°F (-40°C to +70°C) 123 W 33,000 lbs (14,969 kg) 34,500 lbs (15,649 kg) 39,000 lbs (17,690 kg) Post minimum 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket -22°F to +140°F (-30°C to +60°C) Derating occurs over +122°F (+50°C) -22°F to +158°F (-30°C to +70°C) 89 W 30,000 lbs (13,608 kg) 31,500 lbs (14,288 kg) 36,000 lbs (16,330 kg) 267 x 138 x 95 in. (6,782 x 3,506 x 2,413 mm) 267 x 138 x 129 in. (6,782 x 3,506 x 3,277 mm) 410 x 138 x 120 in. (10,414 x 3,506 x 3,048 mm) Post minimum 14 gauge galvanized, shop welded to structural steel base frame & roof z-bracket <3W -22°F to +140°F (-30°C to +60°C) Derating occurs over +45°C 41 W 267 x 138 x 95 in. (6,782 x 3,506 x 2,413 mm) 267 x 138 x 129 in. (6,782 x 3,506 x 3,277 mm) 410 x 138 x 120 in. (10,414 x 3,506 x 3,048 mm) Walls (Enclosure) 1140 A Adjustable 0.8 leading / 0.8 lagging, factory set at 1 Revenue Grade Meter/Monitoring *Please see combiner datasheet for complete subcombiner details MSS 1.5MW-XTM 1/4” steel plate or 3/16” diamond tread steel plate; insulation optional Flooring (Enclosure) 750 kW Communications Data Logger Hardware MSS 1MW-XTM Skid, Canopy or Enclosure Mechanical Weight MSS 0.75MW-XTM Skid, Canopy or Enclosure < 2W -13°F to +140°F (-25°C to +60°C) Derating occurs over +50°C UL 1741/IEEE 1547, UL 1699B, CSA C22.2#107.1, FCC part 15 A&B Certification Agency 98.5% 2W < 45 dBA @ 3 m Safety Listings & Certifications Dimensions (H x W x D) MSS 0.5MW-XTM 1/4” steel plate or 3/16” diamond tread steel plate; insulation optional Performance Subcombiner or Integrated String Combiner MSS 1MW-XT Structural DC Input Maximum Operating Input Current MSS 0.5MW-XT *Transformer options not listed, but may be quoted upon request 1500 kVA, 3-Ph COMBINERS DISCONNECTING COMBINERS RESIDENTIAL RAPID SHUTDOWN COMBINER AFDI COMBINER MONITORING PERFORMANCE Market leading performance: industry leading CEC efficiencies and proven +99.5% uptime. Over 100 years in the power electronics and PV inverter industries with 23M inverters installed worldwide. Specifications Number of Fused Inputs DISCOM DISCOM 1500 ARCCOM 8, 12, 16, 20, 24LT, 24, 30 8, 10, 12, 14, 15, 16, 18, 20, 21, 24 8, 12, 16, 24 Input Wire Range 14-6 AWG 12-8 AWG Max Output Wire Size* 8 10 12 Mech Lug: 350 kcmil, or (2) 300 kcmil Compression Lug: 600 kcmil - 600 kcmil or 750 kcmil 600 kcmil or 750 kcmil 600 kcmil - 600 kcmil or 750 kcmil 14 Mech Lug: 350 kcmil, or (2) 300 kcmil Compression Lug: 600 kcmil - 600 kcmil or 750 kcmil - 15 - 600 kcmil or 750 kcmil - 16 18 20 21 24LT 24 30 Maximum Voltage Maximum Current Fuse Range Operating Temperature Mounting Locations 600 kcmil Enclosure Rating Enclosure Operating Temperature Mounting Locations 600 kcmil or 750 kcmil - 600 kcmil or 750 kcmil - Standard Mech Lug: (2) 600 kcmil Compression Lug: 600 or 750 kcmil Mech Lug: (2) 600 kcmil Compression Lug: 600 or 750 kcmil Mech Lug: (2) 600 kcmil Compression Lug: 600 or 750 kcmil - - Enclosure 600 kcmil or 750 kcmil 600 kcmil - - Safety Listings & Certifications Certification Agency Weight Enclosure Rating 600 or 1000 VDC 1500 VDC 600 or 1000 VDC 96, 144, 192, 240, 250, 288, 360 A 96, 120, 144, 168, 180, 192, 216, 240, 252, 282 A 96, 144, 192, 288 A 4 A, 6 A, 8 A, 10 A, 12 A, 15 A 15 A, 25 A, 30 A 4 A, 6 A, 8 A, 10 A, 12 A, 15 A Enclosure 2 positions per MPPT RELIABILITY DC powered by the array (2.5 W) All inverters are designed and tested to the 15 A included, 20 A maximum highest standards including HALT, field testing -40°F to +158°F (-40°C to +70°C) UL 1741, CSA C22.2#107.1 CSA 10 year SERVICEABILITY Technicians and offices strategically located throughout the U.S.A. and internationally. All minimal downtime. Aluminum PVI 3800-7600TL *Dimensions do not include DC input wiring shown in photos; input wiring is included when RSD is ordered EXPERIENCE Thousands of PV projects ranging in size from UL 1741, CSA C22.2#107.1 UL 1741, CSA C22.2#107.1, UL 1699B partners with PV project owners, investors, ETL ETL inverter solutions. Yaskawa - Solectria Solar developers, EPCs, and distributors throughout the world to build high-performing PV systems, 20/24/30 x 16/20/24 x 6/6/8 in. 30 x 24 x 8 in. (962 x 610 x 203 mm) - (508/610/762 x 406/508/610 x 203/203/203 mm) 20/24/30 x 16/20/24 x 8/8/8 in. 30 x 24 x 8 in. (962 x 610 x 203 mm) 29/36/75 lbs (13.2/16.3/34 kg) 29/36/75 lbs (13.2/16.3/34 kg) 26/29.3/56 lbs (11.8/13.3/25.4 kg) 75 lbs (34 kg) 56 lbs (25.4 kg) Type 4; Optional Type 4X Polyester powder coated steel; optional 316 stainless steel or fiberglass Polyester powder coated steel; optional fiberglass 24 x 20 x 7 in. (610 x 508 x 178 mm) 24 x 20 x 7 in. (610 x 508 x 178 mm) 24 x 20 x 7 in. (610 x 508 x 178 mm) 42/43/44 lbs (19/19.5/20 kg) 42/43/44 lbs (19/19.5/20 kg) 35.3/36.3/37.3 lbs (16/16.5/17 kg) Type 4; Optional Type 4X Polyester powder coated steel; optional 316 stainless steel or fiberglass SolrenView Inverter Direct standard animated view The PVI 14-60TL are compact, three-phase transformerless string inverters designed to maximize reliability and efficiency, while SolrenView GlobalView simplifying installation. The PVI 50-100KW, SGI 225-500PE, GlobalView provides users with the ability to view, sort and search all of their sites monitored by SolrenView. GlobalView is available upon request and simplifies the process of monitoring the performance of multiple sites. It provides one web-based site where users will find site performance details including real-time AC power performance and lifetime power production of all sites combined. and SGI 500XT inverters are time tested, proven solutions for 600VDC applications in both new PV plants and for legacy inverter SolrenView Revenue Grade Energy Production replacement. available upon request optional monitoring package SolrenView Revenue Grade Energy Production Monitoring package option keeps track of lifetime energy produced by a customer’s PV system. This package option also includes e-mail and cell phone alerts with detailed descriptions of system problems and a recommended course of action. Compatible with thirdparty inverters. UTILITY-SCALE INVERTERS SolrenView SolZone DC Current Sub-Array Monitoring optional SolZone provides an extra level of granularity to see multiple sub-array DC currents. SolZone has the ability to compare individual PV zones against each other based on the number of sub-array fuses or ‘zones’ built into a Yaskawa - Solectria Solar factory-installed DC subcombiner. Additional inverter hardware is required for SolZone. This package option also includes e-mail and cell phone alerts with detailed descriptions of system problems and a recommended course of action. SolZone is compatible with most third-party monitoring systems. The SGI XTM inverter series is a line of external transformer inverters designed for direct to medium voltage applications. These inverters have redundant power stages, which optimize reliability and energy harvest. They also include the latest evolution of central inverter SolrenView Agency Reportingoptional technologies proven over the last decade. Advanced Smart Grid SolrenView Agency Reporting is for customers that require a revenue grade energy production report to be sent to an agency such as NEPOOL, WREGIS, MassCEC, PG&E, SCE, CCSE, IID, or PaCE. A report is generated from SolrenView Revenue Grade metering outputs and sent directly to the agency of your choice. Yaskawa - Solectria Solar’s monitoring team works directly with agencies to activate and maintain solar production credit accounts. features are available for utility applications. from residential rooftops to the world’s largest CPV plant. standard monitoring package SolrenView Inverter Direct monitoring allows customers to see detailed operational inverter data (DC and AC) using a web enabled device. This standard package allows customers to view daily, weekly, monthly, and annual graphs up to 5 years into the past, viewing single events or long term performance trends. The package includes e-mail and cell phone alerts with detailed descriptions of system issues and a recommended course of action. The Kiosk View (Animated View) provides customers with a quick and easy access to a customer’s PV system performance. This is a great tool for advertising and public viewing. When the “Animated View” button is clicked on the SolrenView screen, SolrenView will continuously loop through the site overview, environmental footprint, project details, site analytics, and if applicable, the detailed analytics page. Type 4X 1kW to 30MW rely on Yaskawa - Solectria Solar 20/24/30 x 16/20/24 x 6/6/8 in. SIMPLIFYING SOLAR 6.6 lbs (3 kg) Indoor, Outdoor, Wall, Array, Rooftop - Vertical or Horizontal 5 year right choice for large commercial and utility-scale projects. COMMERCIAL INVERTERS Indoor, Outdoor, Wall, Array, Rooftop - Vertical, Horizontal or Angled 8-12 / 16 / 24 technology from reliable partners. Yaskawa - Solectria Solar is the SolrenView monitoring provides PV system owners with a highly accurate and real time webbased monitoring solution to maximize efficiency and profitability of their solar assets. Yaskawa Solectria Solar’s SolrenView web-based monitoring solution is available for use with residential, commercial, and utility-scale inverters, allowing for real-time, seamless recording and reporting of PV system production. The integrated SolrenView data logger is available for all 3-phase central inverters. A standalone SolrenView data logger is available for Solectria’s PVI 38007600TLs and PVI 14-60TLs. The complete SolrenView system features inverter direct monitoring, revenue grade monitoring, agency reporting, SolZone™ sub-array current monitoring, XML feed, kiosk view and weather station. SolrenView Kiosk View inverters are designed for easy service and 12.4 x 10 x 2.2 in (315 x 254 x 56 mm)* PRODUCT SPECIFICATIONS Solar power is reaching cost parity with conventional energy sources and a rigorous design review process. Indoor, Outdoor, Wall, Array, Rooftop - Vertical, Horizontal or Angled -40°F to +122°F (-40°C to +50°C) 5 year class warranties. and project portfolios. Those that will be successful need the best -40°F to +122°F (-40°C to +50°C) 8-12 / 16-20 / 24LT-30 solutions supported by exceptional engineering talent and world 15 A included, 20 A maximum Compatibility Compatible Products Solar offers a versatile line of high-efficiency and high-value inverter in North America, driving aggressive demand for large solar projects Warranty Dimensions (H x W x D) manufacturer based in Lawrence, Massachusetts. Yaskawa - Solectria 600 VDC Certifications Mech Lug: (2) 600 kcmil Compression Lug: 600 kcmil - (508/610/762 x 406/508/610 x 152/152/203 mm) Weight Powder Coated Steel 316 Stainless Steel Fiberglass Fuse Range - (508/610/762 x 406/508/610 x 152/152/203 mm) Fiberglass Integrated Power Supply 600 kcmil or 750 kcmil Standard 316 Stainless Steel Integrated String Combiner 600 kcmil Warranty Dimensions (H x W x D) Powder Coated Steel PV Fuse Size 600 kcmil or 750 kcmil Certification Agency Enclosure Maximum Open Circuit Voltage Mech Lug: (2) 600 kcmil Compression Lug: 600 kcmil - Certifications Safety Listings & Certifications Specifications SolrenView™ Web-Based PV Monitoring Yaskawa - Solectria Solar is a leading grid-tied PV inverter SolrenView Weather Stationoptional SolrenView Weather Station is a real-time weather package which allows customers to view accurate readings of crucial environmental information that may affect the performance of your PV system. The weather station comes standard with a solar irradiance sensor as well as temperature sensors for ambient and module measurements. Wind speed and direction sensors are additional options that may be added to the weather station. The weather station is a great educational tool and a must-have for PPAs. Complies with RS-485 SunSpec Environmental Sensor System. MEGAWATT SOLUTIONS Yaskawa - Solectria Solar offers a variety of fully-integrated MW solutions for both string and central inverters. The Decentralized MW Solution includes all major system components for connecting string inverters to medium voltage (inverters, panelboards, switchboards, and transformers). Megawatt Solar Stations (MSS) Viewable Measurements: - Solar Irradiance - Ambient Temperature - Module Temperature - Wind Speed and Wind Direction (option) SolrenView AIRoptional connect central inverters to a medium voltage transformer as a part The SolrenView AIR option permits customers to take advantage of SolrenView web-based monitoring features via a fully-integrated 4G cellular modem when standard internet access is not available at a site. SolrenView AIR may be factory integrated for any inverter 50kW and greater (PVI 50-100KW, SGI 225-500PE, SGI 500XT, SGI 500/750XTM inverters; not available for PVI 3800-7600TL or PVI 14-60TL inverters). of a prefabricated skid. *See product datasheet on www.solectria.com/documentation for full Output Wire Ranges SolrenView XML Feedoptional YASKAWA – SOLECTRIA SOLAR INVERTERS@SOLECTRIA.COM SOLECTRIA.COM +1 978-683-9700 360 MERRIMACK STREET LAWRENCE, MA 01843 DOCR-070256-G © 2016 YASKAWA – SOLECTRIA SOLAR SolrenView XML feed option provides a reporting framework for customers with a need to display real-time monitoring information about their PV system within their applications/website or using third-party monitoring.