Product Comparison Guide - Synergy Electrical Sales

advertisement
Product Comparison Guide
Electronic Time Switch | Product Cross Reference
Features
Type of Operation
Contact Ratings
Time and Date retention
Scheduled Events
Schedule retention
User interface
Enclosures
SKU’s
Application
Series (Intermatic)
TORK
PARAGON
PRECISION
LUTRON
ET1100
E / E-PB
EC4000
24 Hr
24Hr
24Hr
/
/
30 Amp
40 Amp
30 Amp
/
/
3 Years Battery Back-up
100 Hours Super-Cap
7 Days special-Cap
/
/
28
20
16
/
/
Non-volatile
Non-volatile
Non-volatile
/
/
Easy Programming
Not user friendly
User friendly control
/
/
Type 1 or Type 3R plastic or metal
NEMA 3R Plastic
NEMA 1 steel or NEMA 3R plastic
/
/
9
5
5
/
/
Water heater/indoor and outdoor
lighting/AC/Fans/pumps/Commercial ovens and poultry equipment
Signs/AC/lighting/sump pumps/
ventilating fans
Lighting/HVAC/security system/motor/pump/fan
/
/
ET1700
DG / EW
EL7
Type of Operation
7 Days
7 Days
24Hrs / 7Days / 365Days
/
/
Contact Ratings
30 Amp
40 Amp
20 Amp
/
/
3 Years battery back-up
100 Hrs Super-Cap
96Hrs carry-over
/
/
28
20
128 ON or OFF events, 34 holidays
and 32 sensor events.
/
/
Time and Date retention
Scheduled Events
Schedule Retention
User Interface
External inputs
Input Voltage
SKU’s
Application
Non-Volatile
Non-Volatile
Non-Volatile
/
/
Easy Programming
Not user friendly
User friendly control
/
/
N/A
Sensor/Switch inputs
Sensor/override input terminals
/
/
120 -277 VAC
12VDC, 24VAC, 120 – 277VAC
24 - 277 VAC
/
/
9
16
3
/
/
Water heater/indoor and outdoor
lighting/AC/Fans/pumps/Commercial ovens and poultry equipment
School/traffic lights/Duty cycle/
Lighting and lighting secutrity/HAC
Lighting/HVAC/security system/motor/pump/fan
/
/
Electronic Time Switch | Product Cross Reference
Features
Type of Operation
Contact Ratings
Time and Date retention
Schedule Retention
Series (Intermatic)
TORK
PARAGON
ET90000
ELC
EL7
365 Day
365 Day
24Hr / 7Day / 365Day
PRECISION
LUTRON
/
/
30 Amp
20 Amp
20 Amp
/
/
100 Hrs Super-Cap
1 Week Super-Cap
96Hrs carry-over
/
/
Non-Volatile
Non-Volatile
Non-volatile
/
/
User Interface
Wizard Style
Not user friendly
User friendly control
/
/
External inputs
2 – 8 depending on model
2 – 8 depending on model
5 power inputs / 4-8-12 relays
/
/
Ethernet Module, Relay cards,
Enclosure
Enclosure
Enclosure
/
/
120 -277 VAC
24VAC, 120 – 277VAC
24, 120, 208, 240 and 277 VAC
/
/
2000
128
128
/
/
Replacement Parts
Input Voltage
Schedule Events
Holiday/ Special Events
Remote Connectivity
Stagger Times
Enclosure
SKU’s
Application
99
26
34
/
/
Ethernet
N/A
on-board RS-232 port and the
Pecosoft.EL software
/
/
3 Seconds or Off
5 Seconds – 15 Minutes
n/a
/
/
Type 1 or 3R
NEMA 1 or NEMA 3R
NEMA 1 steel
/
/
12
5
3
/
/
School/Apartment/office/store/
security system/Parking lot lighting/
Airports
HVAC/Lighting
Lighting/HVAC/security system/motor/pump/fan
/
/
Electro-Mechanical Time Switch | Product Cross Reference
Features
Type of Operation
Contact Ratings
Series (Intermatic)
TORK
GM40AV
TU40
24 Hr or 7 Day
24Hr
PARAGON
PRECISION
LUTRON
/
/
/
40 Amp
40 Amp
/
/
/
7 day carry over (some models)
Not available
/
/
/
Scheduled Events
48
48
/
/
/
Schedule retention
7 day carry over (some models)
Not available
/
/
/
Operating Temperature
-40° - 131° F
-31° - 116° F
/
/
/
Enclosures
Type 3R plastic
NEMA 3R Plastic or NEMA 1 metal enclosure
/
/
/
5
2
/
/
/
lighting/HVAC/pumps/motors/general elecctrical
circuits in residential, commercial, industrial and
agricultural facilities
pumps/motors/fans/signs/lighting/water heater/
HAC
/
/
/
GM40AVE
DTU40
24 Hr or 7 Day
24Hr or 7 Day
/
/
/
40 Amp
40 Amp
/
/
/
Battery Back-up
Battery Back-up
/
/
/
Time and Date retention
SKU’s
Application
Type of Operation
Contact Ratings
Time and Date retention
Scheduled Events
20
14
/
/
/
Schedule retention
Non-Volatile Memory
Battery Back-up
/
/
/
Operating Temperature
-40° - 131° F
-31° - 116° F
/
/
/
Enclosures
Type 3R Plastic
NEMA 3R Plastic
/
/
/
1
1
/
/
/
lighting/HVAC/pumps/motors/general elecctrical
circuits in residential, commercial, industrial and
agricultural facilities
pumps/motors/fans/signs/lighting/water heater/
HAC
/
/
/
SKU’s
Application
Mechanical Time Switch | Product Cross Reference
Features
Type of Operation
Contact Ratings
Series (Intermatic)
TORK
PARAGON
PRECISION
T100
1100
4000
CD100
24 Hr
24Hr
24Hr
24Hr
LUTRON
/
40 Amp
40 Amp
40 Amp
40 Amp
/
CSA
UL and CSA
UL and CSA
n/a
/
-40° - 130° F
-40° - 165° F
-40 to 180
n/a
/
Minimum ON time
1 Hour
20 Minutes
90 Minutes
1 hour between ON & OFF
/
Minimum OFF time
1 Hour
75 Minutes
90 Minutes
2 Hours between OFF & ON.
/
SPST, SPDT, DPST
SPST, DPST
SPST, DPST, SPDT
SPST, DPST, SPDT
/
Type 1 metal, Type 3R plastic or metal
NEMA 1, NEMA 3R plastic or metal
(Noryl)
NEMA 1, indoor metal
Raintight NEMA 3
/
Agency
Operating Temperature
Switch Offerings
Enclosure
Input Voltage
SKU’s
Application
Type of Operation
Contact Ratings
120- 277 VAC
120- 347 VAC
120 - 277 VAC
120, 240 VAC
/
19 (Mech only not included)
16 (Mech only not included)
23
6
/
lighting/pumps/signs/fans/AC/Water
heaters
lighting/pumps/signs/fans/AC/Water
heaters
Lighting/HVAC/Signs/Heater/Music
and signal system/motor/pump/fans/
electric fences
replaces the Intermatic T100 series and
Tork 1100
/
/
/
T170 / T1400 / T1800
7000
4000-00
24 Hour w/ Skip a day feature
24 Hour w/ Skip a day feature
24 Hour w/ Skip a day feature
40 Amp
40 Amp
40 Amp
/
/
CSA
UL and CSA
UL and CSA
/
/
-40° - 130° F
-40° - 165° F
-40° - 180° F
/
/
Minimum ON time
1 Hour
20 Minutes
90 Minutes
/
/
Minimum OFF time
1 Hour
75 Minutes
90 Minutes
/
/
Agency
Operating Temperature
Switch Offerings
Enclosure
Input Voltage
SKU’s
Application
SPST, SPDT, DPST, DPDT, 4PST
SPST, SPDT, DPST, DPDT, 3PST
SPST, DPST, SPDT
/
/
Type 1 metal, Type 3R plastic or metal
NEMA 1, NEMA 3R plastic or metal
(Noryl)
NEMA 1, NEMA 3 and NEMA 3R
/
/
120, 208-277, 480 VAC
120, 208-277 VAC
24, 120, 208, 277 VAC
/
/
16
19 (Units with bracket to fit into Intermatic enclosure not included)
13
/
/
Lighting/HVAC/Signs/Heater/ Music and
signal system/motor/pump/fans/electric
fences
/
/
lighting/pumps/signs/AC/heating
lighting/pumps/signs/AC/heating
Mechanical Time Switch | Product Cross Reference
Features
Series (Intermatic)
TORK
PARAGON
PRECISION
LUTRON
/
/
T1900
8000
1015
Type of Operation
24 Hour
24 Hour
24 Hour w/ Skip a day feature
Contact Ratings
20 Amp
20 Amp
10 Amp
/
/
CSA
UL and CSA
UL and CSA
/
/
-40° - 130° F
-40° - 165° F
-40 to +130
/
/
Minimum ON time
15 Minutes
15 Minutes
15 Minutes
/
/
Minimum OFF time
15 Minutes
15 Minutes
15 Minutes
/
/
No mention of this in catalog
Adjustable from1/2, 1, 2, 3, 4, 6, 12,
and 24 hours
n/a
/
/
SPDT
SPDT
SPST, DPST, SPDT
/
/
Type 1 metal, Type 3R plastic or metal
NEMA 1, NEMA 3R plastic or metal
(Noryl)
NEMA 3
/
/
120, 208-277, 480 VAC
120, 208-277, 480 VAC
120, 208-240, 480 VAC
/
/
Agency
Operating Temperature
Duty Cycling
Switch Offerings
Enclosure
Input Voltage
Skip – a – day feature
SKU’s
Application
7 days version only
7 days or 14 days version
7 days version only
/
/
12 (Mech only not included)
18 (Mech only not included)
3
/
/
Ventilating fans/pumping/irrigation/process control/laboratory experiments
Duty cycling/ventilating fans/pumping/
irrigation/process control/laboratory
experiments
Ventilating fans/pumping/irrigation/
process control/laboratory experiments
/
/
Mechanical Time Switch | Product Cross Reference
Features
Type of Operation
Contact Ratings
Agency
Operating Temperature
Minimum ON time
Trippers
Switch Offerings
Enclosure
Input Voltage
Dial Cycle
SKU’s
Application
Series (Intermatic)
TORK
C88000
8000
24 Hour Cycle Timer
24 Hour Cycle Timer
PARAGON
PRECISION
LUTRON
/
/
/
20 Amp
20 Amp
/
/
/
CSA
UL and CSA
/
/
/
-40° - 130° F
-40° - 165° F
/
/
/
5 Seconds – 2 Minutes
6 Seconds – 1 Minute
/
/
/
Removable
Captive
/
/
/
SPDT
SPDT
/
/
/
Type 1 metal
NEMA 1 metal
/
/
/
120, 208-277 VAC
120 VAC
/
/
/
10, 30, 60 minutes, and 4 hours
6, 12, 30, and 60 minutes
/
/
/
5
4
/
/
/
Duty cycling/ventilating fans/pumping/
irrigation/process control/laboratory
experiments
Duty cycling/ventilating fans/pumping/
irrigation/process control/laboratory
experiments
/
/
/
In-Wall Timer | Product Cross Reference
Features
Type of Operation
Input Voltage
Time and Date retention
Scheduled Events
Operating Temperature
Random mode
SKU’S
Application
Type of Operation
Input Voltage
Time and Date retention
Scheduled Events
Operating Temperature
Random mode
SKU’S
Application
Series (Intermatic)
TORK
ST01
SS700Z
PARAGON
PRECISION
LUTRON
7 Day - Astromic feature
7 Day - Astronomic feature
/
/
/
120 - 277 VAC
120 - 277 VAC
/
/
/
CR2 Lithium battery (3 years)
2 Day real time backup - Supercap
/
/
/
40
10
/
/
/
32 to 122 F
32 to 104 F
/
/
/
NO
YES
/
/
/
2
4
/
/
/
Indoor&Outdoor lighting, LED / Flourescent / CFL
/ incandescent
Outdoor security lighting/Fans/appliances/livedin look
/
/
/
EJ600
SS720A
24 Hrs or 7 days - Astronomic feature
24 Hrs or 7 Days
/
/
/
120 VAC
125 VAC
/
/
/
Built-in rechargeable lithium ion battery
Rechargeable Ni-MI battery
/
/
/
7
7
/
/
/
32 to 104 F
n/a
/
/
/
NO
YES
/
/
/
3
2
/
/
/
Outdoor lighting / aplliances
Outdoor security lighting/Fans/appliances/livedin look
/
/
/
In-Wall Timer | Product Cross Reference
Features
Type of Operation
Input Voltage
Time and Date retention
Scheduled Events
Operating Temperature
Random mode
SKU’S
Application
Type of Operation
Input Voltage
Events
Warning
CFL / LED compatible
Accuracy
SKU’S
Application
Series (Intermatic)
TORK
PARAGON
PRECISION
LUTRON
EJ500
SS720A
7 Days - Astromic feature
24 Hrs or 7 days
/
/
/
120 VAC
125 VAC
/
/
/
Battery Back-up
Rechargeable Ni-MI battery
/
/
/
7
7
/
/
/
32 to 104 F
n/a
/
/
/
NO
YES
/
/
/
3
2
/
/
/
only for CFL
Outdoor security lighting/Fans/appliances/livedin look
/
/
/
EI400
SSA
Electronic Auto-Off
Digital Auto-Off
/
/
/
120-277 VAC
120-277 VAC
/
/
/
1 - countdown timer
8 preset ON intervals
/
/
/
Audible & Visual
Audible & Visiual
/
/
/
YES
NO
/
/
/
To-the-second
0.002%
/
/
/
3
5
/
/
/
Indoor Lighting / offices
Office/library aisles/stock,utility,equipment
rooms/bathrooms/Hot tub heaters/circulating
pump/HVAC
/
/
/
In-Wall Timer | Product Cross Reference
Features
Type of Operation
Series (Intermatic)
TORK
EI200
D1060 / D212
Electronic Countdown
Electronic Countdown
/
/
n/a
Input Voltage
Range
PRECISION
LUTRON
Maestro
120 VAC
120 VAC
/
/
n/a
From 5min to 12Hr
From 10min to 12Hr
/
/
n/a
32 to 122 F
32 to 122 F
/
/
n/a
Operating Temperature
SKU’S
Application
PARAGON
7
6
/
/
n/a
closet/bathroom fan/lights hot tub/spa
Fans/Indoor and outdoor lighting/bathrrom/self
storage
/
/
n/a
FD
A500
PD
Type of Operation
Auto-Off Timer
Auto-off Timer
/
Spring Wound Timer
/
Input Voltage
125-250/277 VAC
120-250/277 VAC
Range
From 5min to 6Hrs
From 15min to 12Hrs
/
120-250/277 VAC
/
/
From 15min to 12Hrs
/
Hold Feature
n/a
Some models
/
n/a
/
SKU’S
Application
20
20
/
4
/
closet/bathroom fan/lights hot tub/spa
Fans/Indoor and outdoor lighting/bathrrom/self
storage
/
n/a
/
SKU’S
3
2
/
/
/
Application
only for CFL
Outdoor security lighting/Fans/appliances/livedin look
/
/
/
In-Wall Timer | Product Cross Reference
Features
Type of Operation
Series (Intermatic)
TORK
FF
C500
Auto-Off Timer
Auto-off Timer
PARAGON
PRECISION
LUTRON
PM
/
Spring Wound Timer
/
Input Voltage
125-250/277 VAC
120-250-277 VAC
/
120-250/277 VAC
/
Range
From 5min to 12Hrs
From 15min to 12Hrs
/
From 15min to 12Hrs
/
Some models
Some models
/
n/a
/
29
10
/
4
/
closet/bathroom fan/ lights hot tub/spa
Fans/Indoor and outdoor lighting bathrrom/self
storage
/
n/a
/
Hold Feature
SKU’S
Application
SKU’S
Application
Type of Operation
Input Voltage
Interval
Scheduled Events
3
5
/
/
/
Indoor Lighting / offices
Office/library aisles/stock,utility,equipment
rooms/bathrooms/Hot tub heaters/circulating
pump/HVAC
/
/
/
KM2
700A
24 Hr - Mechanic Inwall
24 Hr - Mechanic Inwall
/
/
/
120 VAC
125 VAC
/
/
/
20min
30min
/
/
/
72 trippers (36 events)
48 trippers (24 events)
/
/
/
Use with CFL
YES
n/a
/
/
/
Use with LED
n/a
n/a
/
/
/
SKU’S
Application
Type of Operation
7
5
/
/
/
House fan/ventilation/ outdoor lighting
Porch/Patio/Doorway/ Pool/Outdoor security
lighting
/
/
/
E1000
M500
Heavy Duty Inwall
Motor operated Inwall
/
/
/
Photo Controls | Product Cross Reference
Features
Series (Intermatic)
TORK
K4200
2001
Polycarbonate
Lexan
/
Weatherproof Lexan
/
Use with CFL
Yes
Yes
/
n/a
/
Use with LED
Yes (small number)
Yes (they claim)
/
n/a
/
1 -2 Years
5 Years
/
5 Years
/
Housings
Warranty
Input Voltage
SKU’S
Application
Housings
PARAGON
PRECISION
LUTRON
ST-15
120 – 480 VAC
120 – 480 VAC
/
120
/
41 (excluding accessories)
39 (excluding accessories)
/
4
/
street/parking lot/billboard/security lighting
Parking Lot/Building/Outdoor
/
Outdoor lighting
/
K4200
2020
PN 201-00
ET-15 ET-168
Polycarbonate
Lexan
n/a
Weatherproof Lexan
/
Use with CFL
? (Catalog doesn’t state that they work with CFL)
Yes (they claim that they work with CFL)
n/a
n/a
/
Use with LED
No literature stating this
Yes (they claim, no EB Rating for this though)
n/a
n/a
/
Warranty
2 Years
5 Years
n/a
5 Years
/
120 – 480 VAC
120 – 480 VAC
n/a
120, 208-277 VAC
/
4
4
n/a
2
/
residential outdoor/street/parking lot/billboard/security
lighting
Flood and patio lamp
n/a
n/a
/
K4400
2100
CW 201-00 / CW
201-71
T-AL
Heavy Duty Die Cast
Die Cast Zinc
n/a
Vandal proof die cast
aluminium
/
Use with CFL
? (Catalog doesn’t state that they work with CFL)
Yes (they claim that they work with screw based CFL
& LED)
n/a
n/a
/
Use with LED
No literature stating this
Yes (they claim, no EB Rating for this though)
n/a
n/a
/
2 years
5 Years
n/a
n/a
/
120 – 277 VAC
120 – 277 VAC
n/a
120, 208-277 VAC
/
Input Voltage
SKU’S
Application
Housings
Warranty
Input Voltage
SKU’S
Application
3
3
n/a
4
/
Parking Lot/Building perimeter lighting/Outdoor signs
n/a
n/a
/
Photo Controls | Product Cross Reference
Features
Series (Intermatic)
TORK
PARAGON
PRECISION
LUTRON
/
/
/
2110
Housings
/
Die Cast Aluminum
Use with CFL
/
Yes (they claim that they work with screw based CFL & LED)
/
/
/
Use with LED
/
Yes (they claim, no EB Rating for this though)
/
/
/
Warranty
/
5 Years
/
/
/
Input Voltage
/
120 – 277 VAC
/
/
/
SKU’S
/
3
/
/
/
Application
/
Parking Lot/Building perimeter lighting/Outdoor signs
/
/
/
K4100
Housings
CW 201-71
Polycarbonate
/
n/a
/
/
Use with CFL
? (Catalog doesn’t state that they work with CFL)
/
n/a
/
/
Use with LED
No literature stating this
/
n/a
/
/
Warranty
Input Voltage
SKU’S
Application
1 - 2 Years
/
n/a
/
/
120 – 480 VAC
/
n/a
/
/
5
/
n/a
/
/
Thermal type photo controls - Outdoor lighting
/
n/a
/
/
Occupancy/Vacancy Sensor | Product Cross Reference
Features
Series (Intermatic)
TORK
IOS
OSC
PIR (Passive Infrared)
Yes
Yes
/
/
Yes
Dual-Tech
No
Yes
/
/
Yes
Ultrasonic
No
Yes
/
/
Yes
Warranty
1 -3 Years
n/a
/
/
1 Year
Input Voltage
24 VDC, 120 – 277 VAC
24 VDC, 120 – 347 VAC
/
/
20-24 VDC, class 2 (PELV) low-voltage
wiring
SKU’S
21 (including power pack)
16 (including power pack)
/
/
24 (including power pack)
Fixed on ceiling s
Office/conference room/hotel/school/lavatories/
hallways
/
/
n/a
IOS-D
OSW
Application
PARAGON
PRECISION
LUTRON
LOS C
LOS W
PIR (Passive Infrared)
Yes
Yes
/
/
Yes
Dual-Tech
No
Yes
/
/
Yes
Ultrasonic
No
Yes
/
/
Yes
Warranty
1 -3 Years
n/a
/
/
1 Year
Input Voltage
24 VDC, 120 – 277 VAC
24 VDC, 120 – 347 VAC
/
/
20-24 VDC, class 2 (PELV) low-voltage
wiring
SKU’S
21 (including power pack)
16 (including power pack)
/
/
8 (including power pack)
fixed on walls
Office/conference room/hotel/school/lavatories/
hallways
/
/
n/a
Application
Download