Volumetric Meter

advertisement
Uvitem
Ultravioleta, Tecnología
y Maquinaria, S.L.
Volumetric Meter
with IP-55 or Eexd Protection
Uvitem include in the line of products a
wide range of volumetric meters.
AFE
M.R.O Low Flow Serie
CEB/09
Flange Series
Agressive Liquid Series
M.R.O Medium Flow Serie
M.R.O High Flow Serie
CE 2000 P Programmer
Converter M-A-I-C
Pol. Ind. La Esperanza, c/ País Vasco, Parc. 29-30 Apdo. Correos 133 - 12400 SEGORBE (Castellón)
Tel. 96 471 40 32 - Fax 96 471 39 19, E-mail: info@uvitem.com - web: www.uvitem.com
________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
Flowmeters
OVAL WHEELS
Materials:
Stainless steel / Bronze
Accuracy:
± 0'4%
Pipe connection:
Thread / flange
TURBINE
Materials:
Stainless steel
(PVC, PVCF TX range)
Accuracy:
±1%
Pipe connection:
Thread / flange
ELECTROMAGNETICS
Flow Range
MODELS
Low
Flow
Medium
Flow
High
Flow
MODELS
Flow Range
MODELS
Flow Range
Materials:
Stainless steel, teflon
Accuracy:
± 0'5%
Pipe connection:
Different options
Additional Fittings
READING HEAD CEB/09
Functions: (depending on model)
Pulse output
4 – 20 mA Output
Flow indication
Totalization
Parcial with reset to zero
PROGRAMMER-METER CE 2000-P
Functions:
Pre-selection and dosage
Volume totalizing counter
Parcial volume counter and reset to zero
Constant value setting on counter
Two-stage batching
M-A-I-C
Functions:
Frequency / current converter
Flow / totalizer indication
4 – 20 mA, 0 – 10 V, 0 – 20 mA outputs
Completely configurable
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
Meters and Oval Wheels Flowmeter
Stainless Steel Series
FEATURES
· STRONG AND
SIMPLE UNIT MADE OF
STAINLESS STEEL AISI 316
·
SPECIALLY SUITABLE FOR VISCOUS
LIQUIDS (up to 100.000 cP), FOOD LIQUID
and / or CORROSIVE LIQUIDS
· HIGH
TEMPERATURE RESISTANT (Up
to 250ºC) and PRESSURES (Up to 500 bar)
AVAILABLE
·
HIGH ACCURACY (less than 0'4%)
·
A U T H O R I Z E D B Y S PA N I S H
METROLOGY CENTER (CENTRO
ESPAÑOL DE METROLOGÍA – C.E.M.)
MAIN APPLICATIONS
· FOOD LIQUIDS
-
EDIBLE OILS (olive, sunflower, soya oils,
etc.)
BUTTER AND FAT
LIQUID EGGS
GLUCOSE, CHOCOLATE AND HONEY
JUICE CONCENTRATE
ALCOHOL AND LIQUOR
MILK, YOGURT and FERMENT
FOOD ADDITIVES, Etc.
· OTHER LIQUIDS
-
WATER and PEROXIDE
DETERGENTS, FABRIC SOFTENER,
GELS and SURFACTANT
RESINS, PAINTS, AND SOLVENTS
ACID and BASES
FERTILIZER
OTHER CHEMICAL PRODUCTS, etc.
3
4
________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
OPERATING PRINCIPLE
OPTIONS
These flowmeters work by positive
displacement. Its operating principle consists
in the capture of a small volume of fluid
and driving it through the flowmeter doing
the same steps. Two meshed oval driving
pinion drive the liquid inside the
measurement chamber. If number of
revolutions of oval wheels are determined
the volume of fluids can be metered.
METER ASSEMBLY
· Oval wheel shafts must always be
horizontally assembled regardless of
meter position.
· Outlet meter must always be full of
product.
· Fluid must never move backwards.
· Place an appropriate filter at meter inlet.
· Liquid pressure up to 40, 64, 100 and 500
Bar
· Reading head:
- CEB09 self-powered
- CEB09/SI with pulse output self-powered
-CEB09/SIA with pulse output and
analogic. Power supply 24v (ac-dc).
- CEB09 Eexd flame proof.
- CEB09/SIA Eexd with pulse outlet and
analogic, flame proof.
- CEB07 flame proof
· Connections: flange DIN and ANSI
· Heating chamber for steam and thermal
oil up to 300ºC and 1/2” gas thread
connections.
· Oval wheels with stainless steel bearings.
· Increase of accuracy (pulses/liters) from 2
to 10 times depending on model.
IMPROPER
ASSEMBLY
CORRECT
ASSEMBLY
· Liquid temperature up to 90ºC, 120ºC,
150ºC and 250ºC.
TECHNICAL SPECIFICATIONS
TEMPERATURE (ºC)
MODEL
Standard
PRESSURE (Bar)
Maximum
(optional) Standard
up to
Maximum
(optional)
up to
FLOW (l/h)
(1)
Minimum Maximum
MATERIALS
Wheels
Body
CONNECTIONS
Options
(2)
Gas
Flanges Flanges
DIN NW Thread
DIN
ANSI
Thread
(1) Suitable for liquids viscosity of 1 mPa/sec. For liquids with other viscosity, please consult G-Flow.
(2) For other flanges, please consult G-Flow.
DIMENSIONS (mm)
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
Oval Wheels Meters
Medium Flow Series
5
6
________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
Oval Wheel Flow Meters
Medium Flow Series
MAIN ADVANTAGES
· High accuracy, +-0'4%
TECHNICAL SPECIFICATIONS
· Reliable, strong and simple unit.
· Maximum working temperature
- Standard 55ºC
- Maximum 120ºC
· Low pressure drop.
· Approved by spanish metrology center
(centro español de metrología – C.E.M.)
· Several uses: chemical industry,
pharmaceutical industry...
· Measuring range
RIM – RBM 20 0'2 – 2 m3/h
RIM – RBM 32 0'6 – 6 m3/h
RN – RA - RI 50 2 – 20 m3/h
· Several options: pulse outlet, 4-20 mA,
total volume meter, parcial volume meter,
reset to zero...
· Viscosity: 1'5 – 100.000 mP.s
OPERATING PRINCIPLE
· Connections
RIM – RBM 20 / 32:
- Thread DIN 11851 DN25 / GAS 1
1/4”
- Flange DIN 2635 PN 25
- Flange ANSI B16'5 CLASS 300
DIN 1 1/42”
RN – RI 50:
- Flange DIN 2636 DN50 PN64
RA 50:
- Rosca DIN 11851 DN50
These flow meters work by positive
displacement. Its operating principle consists
in the capture of a small volume of fluid and
driving it from inlet to outlet passing through
the same steps. Two meshed oval driving
pinion drive the liquid inside the measurement
chamber. If number of revolutions of oval
wheels are determined the volume of fluids
can be metered.
· Maximum working pressure: 16 bar
· Materials
- Wheels AISI 316 or bronze
- Body AISI 316 or bronze
- Shaft AISI 316
DIMENSIONS
MODEL
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
Meters and oval Wheels Flow Meter
Aluminium Series
FEATURES
· RELIABLE AND LIGHTWEIGHT
MADE OF DURALUMIN
· SPECIALLY SUITABLE FOR LIGHT
AND CLEAN HYDROCARBON
· MAINTENANCE AND PURCHASE
LOW COSTS
· HIGH ACCURACY (less than 0'4%)
· LOW PRESSURE DROP
· MARKETING AUTHORIZED BY
SPANISH METROLOGY CENTER
( C E N T R O E S PA Ñ O L D E
METEOROLOGÍA – C.E.M.)
MAIN APPLICATIONS
·
HYDROCARBONS
-
DIESEL OIL
GASOLINE
KEROSENE
CLEAN MINERAL OIL
7
8
________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
OPERATING PRINCIPLE
OPTIONS
These flow meters works by positive
displacement. Its operating principle consists
in the capture of a small volume of fluid and
driving it from inlet to outlet passing through
the same steps. Two meshed oval driving pinion
drive the liquid inside the measurement
chamber. If number of revolutions of oval
wheels are determined the volume of fluids
can be metered.
· Liquid temperature up to 90ºC.
· Reading head:
- CEB09 self-powered
- CEB09/SI with pulse output selfpowered
- CEB09/SIA with pulse output and
analogic. Power supply 24v (ac-dc).
- CEB09 Eexd flame proof.
- CEB09/SIA Eexd with pulse outlet
and analogic, flame proof.
- CEB07 flame proof
METER ASSEMBLY
· Oval wheel shafts must always be
horizontally assembled regardless of
meter position.
· Outlet meter must always be full of
product.
· Fluid must never move backwards.
· Place an appropriate filter at meter
inlet.
IMPROPER
ASSEMBLY
CORRECT
ASSEMBLY
TECHNICAL SPECIFICATIONS
FLOW (l/h)
TEMPERATURE (ºC)
MODEL
Standard
Maximum
(optional) up to
PRESSURE
(Bar)
MATERIALS
(1)
Minimum Maximum
Wheels
Body
CONNECTIONS
Lids
Aluminum Aluminum
6082
7075
Aluminum Aluminum
7075
6082
Aluminum Aluminum
7075
6082
(1) Values only valid for diesel oil. For other liquids, please consult G-Flow.
Gas Internal
Thread
DIMENSIONS (mm)
A
B
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
Meters and Turbine Flow Meter
Serie Stainless Steel
FEATURES
· STRONG AND RELIABLE UNIT
MADE OF STAINLESS STEEL
· MAINTENANCE AND
PURCHASE LOW COSTS
· SPECIALLY SUITABLE FOR
LOW VISCOSITY LIQUIDS (up
to 30 cP)
· HIGH TEMPERATURE
RESISTANT (Up to 200ºC) and
PRESSURES (Up to 300 bar)
AVAILABLE
· HIGH ACCURACY (error lesser
than 1%)
· HIGHER ACCURACY AT
SPECIFIC FLOWS (CC4
Certificate)
MAIN APPLICATIONS
· FOOD LIQUIDS
- WINE, VINEGAR and ALCOHOL
- RON, WHISKY, GIN, etc
- HORCHATA (Sweet drink)
- MILK AND WHEY
- BEER
- SOME JUICES
- WATER AND MINERAL WATER
· NON-FOOD LIQUIDS
- LIQUID FERTILISER
- DE-MINERALISED WATER
- PEROXIDE
- STEAM CONDENSATE
- SOLVENTS
- ISOCYANATE, FORMOL
- DIESEL OIL, GASOLINE and
QUEROSENE
9
10 ________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
OPERATING PRINCIPLE
OPTIONS
Turbine flow meters are provided with a rotor
which rotates when the fluid applies a force to
the rotor's blade. Rotational speed is
proportional to the flow, so volume of fluid
will de determined by rotor's speed. In order
to know speed of rotor, a sensor detects each
pass of the blade. The frequency of pulses of
the sensor determines the flow passing through.
· Liquid temperature up to 90ºC, 120ºC,
150ºC and 200ºC.
· Liquid pressure up to 300 Bar
· AISI 316 material and turbine casing
by HALAR
· Reading head:
- CEB09 self-powered
- CEB09/SI with pulse output selfpowered
- CEB09/SIA with pulse output and
analogic. Power supply 24v (ac-dc).
- CEB09 Eexd flame proof.
- CEB09/SIA Eexd with pulse outlet and
analogical, flame proof.
- CEB07 flame proof
· Pipe connection: flange DIN and ANSI
METER ASSEMBLY
Better use a straight pipe for meter assembly
with the same internal diameter than the meter
and no less than 5 times the diameter at outlet
point, and 10 times at inlet.
The placement of the meter in the pipe is
indicated by means of an arrow printed on
meter's body. The arrow also indicated the
direction of the fluid.
The meter can be assemble horizontal or
vertically. However, it is recommended a
vertical position as shown on figure below.
RIGHT ASSEMBLIES
BAD
ASSEMBLY
TECHNICAL SPECIFICATIONS
TEMPERATURE (ºC)
MODEL
PRESSURE (Bar)
Maximum
Maximum
Standard (optional) Standard (optional)
up to
up to
FLOW (l/h)
(1)
CONNECTIONS
MATERIALS
Minimum Maximum Turbines
Body
Standard
(1) Suitable for water. For liquids with other viscosity, please consult G-Flow.
Option
Standard
Thread
Clamp
Connection
Options
Flanges
DIN
Flanges
ANSI
DIMENSIONS (mm)
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
Electromagnetic Meters and Flow Meters
Serie AFE
FEATURES
· SPECIALLY INDICATED FOR
CLEAN CONDUCTIVE LIQUIDS
OR WITH SUSPENDED SOLIDS.
· STRONG AND SIMPLE UNIT
WITHOUT INTERNAL MOBILE
COMPONENTS
· INTERNAL TUBE MADE OF
TEFLÓN PFA:
- FOOD PROCESSING industry
(specific connection optional)
- High resistance against CHEMICAL
AND ABRASIVE PRODUCTS
MAIN APPLICATIONS
· FOOD-PROCESSING INDUSTRY
- MILK and MILK PRODUCTS
- BEER
- WINE, VINASSE and non-filtered
MUST.
- FRUIT JUICE
- CHOPPED OR FRIED TOMATO
- SAUCE AND JELLY
- DRINKABLE WATER
- LIQUIDS WITHOUT WATER
· OTHER APPLICATIONS
- SULPHURIC ACID
- SODA and CITRIC ACID
- SYNTHETIC RESINS
- CALCIUM CARBONATE
- DETERGENTS AND
SURFACTANTS
- WASTE WATER etc.
11
12 ________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
MAIN FEATURES
· No mobile components which means low
pressure drop
· Internal tube TEFLON PFA and electrodes
by Hastelloy C4
· Suitable for food-processing industry with
optional specified connections
· Chemical products resistant
· High resistant against abrasión
OPERATING PRINCIPLE
The conductive liquid passes through the
metering tube applying electric voltage
between two electrodes (“sandwich
connection”) as an electromagnetic field
has been created across the tube. This
voltage is proportional to speed and
therefore, proportional to the flow.
· Easy installation
· Power supply: 220Vca
· Pulse outlet and 4-20 mA
· IP67 protection
· Current and total flow indication
· Waffer connection (between flanges)
TECHNICAL SPECIFICATIONS
MODEL
PRESSURE TEMPERATURE (ºC)
MAX.
(Bar)
Min
Max
FLOW (l/h)
Min
CONNECTION
MATERIALS
(1)
Standard
Max
Internal Tube
Electrodes
External Tube Sandwich
Teflon reinforces with
stainless steel mesh
Steel with epoxi
Teflon reinforces with
stainless steel mesh
Steel with epoxi
Teflon reinforces with
stainless steel mesh
Steel with epoxi
Teflon reinforces with
stainless steel mesh
Steel with epoxi
Teflon reinforces with
stainless steel mesh
Steel with epoxi
Option
Flange
Clamp
DIMENSIONS
(mm)
A
B
C
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
Turbine-TX Flow Meter
Serie Corrosive Liquids
13
14 ________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
Turbine Meters
MODEL TX
MAIN ADVANTAGES
FEATURES
The TX flow meter is G-FLOW’s answer to the
market demands, asking for a reliable, accurate
and inexpensive flow meter for the measuring of
corrosive liquids.
- Max. working pressure: 6 bar
It’s a paddle turbine flow meter. The flow sensor
consists of a transducer and an open-cell paddle
wheel. When immersed in the flow, the rotating
paddle-wheel produces a frequency modulated
measuring signal proportional to the flow.
- Accuracy:
The TX model offers an effect hall pulse output.
Optionally it can provide a display and a 4-20
mAoutput.
Flow range varies from 500 L/h in the smallest
sized models up to more than 3000 m3/h in the
largest.
Materials have been carefully chosen in order to
provide an appropriate solution for corrosive liquid
measuring (HCl, i.e.)
- Max. working temperature:
Three-wire sensor: 80ºC
- Output:
± 1% of measured value
Three wire sensor : rectangular
0..200 Hz pulse output
- Voltage supply:
Three wire sensor: 12...30 VDC
- Protection Index:
IP 65
- Materials
- Fittings:
Rotor: PVDF
Sensor housing: PVDF
Axis and bearings: ceramic
Fittings: PVC standard
PVDF on request
Socket union (up to DN 50)
Saddles (diameters DN 65 ... DN 200
DIMENSIONS
DN
External
Diameter
PVC (SOCKET UNION)
DN
PVC WITH COLLAR
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
FLOW RATE INDICATOR – CEBO9
· Total, partial and flor
· Pulse input: NAMUR, reed,
PNP, NPN, ENCODER
· Total, partial, flor
· Pulse input: NAMUR, reed,
PNP, NPN, ENCODER
· Protection against hits
· Flame-proof (optional)
· Total, partial, flor
· Pulse input: NAMUR, reed,
PNP, NPN, ENCODER
· Pulse output
· Total, partial, flor
· Pulse input: NAMUR, HALL,
reed, PNP, NPN, ENCODER
· Pulse output
· 4-20 mA output
15
16 ________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
CEB09 indicates in the display volume and flow rates. It is compatible with the
following pulse emitters:
·
CEB09, CEB09/SI, SCEB9 and SCEB09/SI: NAMUR, REED, PNP, NPN, ENCODER
·
CEB09/SIA and SCEB09/SIA: NAMUR, HALL, REED, PNP, NPN, ENCODER
Sensor sends pulses out to the flow rate indicator. By means of the constant pulses/liter
(number of pulses per liter), the reading device indicates:
· TOTAL VOLUME of liters measured from the beginning of the operation. LCD and 8
digits display show the measurements.
· PARTIAL VOLUME of liters and reset to zero (partial meter). LCD display for 5 10mm
digits.
· INSTANTANEOUS FLOW RATE (liters per unit of time). LCD display for 5 10mm
digits.
· PLC available for a remote control of meter. Models CEB09/SIA and SCEB09/SI (optional).
· 4-20 mA OUTPUT proportional to flow rate (optional). Models CEB09/SIA and SCEB09/SIA
available.
One of the main features of CEB09, SCEB09, CEB09/SI and SCEB09/SI models is the 57 years autonomous battery. This features easies the installation and makes possible the use
of this readings units in places where is difficult to find power supply.
1 - PARTIAL METER
2 - FLOW
FLOW INDICATION RATE OR PARTIAL
MEASUREMENT UNITS
INDICATION
FLOW
LITERS
LITER INDICATOR or m3
TOTAL MULTIPLIER
TOTAL VOLUME RATE
LOW BATTERY CHARGE INDICATOR
CONTACESA LOGO
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
Frequency 4/20mA Converter
M-A-I-C
PULSE
GENERATOR
FLOWMETERS
PULSES
PLC
17
18 ________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
Multifunction Frequency Converter
The new M.A.I.C lets turn any pulse
input –generated by flowmeters,
encoders, etc- into a current or voltage
output which is proportional to the input
pulses. It also divides the input pulses
by a factor “K”.
TECHNICAL SPECIFICATIONS
·
·
·
·
·
·
·
·
·
·
·
·
·
Voltage: 220 Vac, 50/60 Hz
Power: 3,2 VA
Pulse input: Namur, NPN
Maximum pulse input frequency: 1000
Hz
Minimum pulse input frequency: 0.09
Hz
Analogic output: 4 – 20 mA / 0 – 10 V
Pulse divider:
litres per 0.01, 0.1, 1, 10, 100 y 1000.
Pulse output:
Relay and open collector.
Alphanumeric display. 2 lines and 16
characters
Working temperature range: 0 – 40 º C
Mounting: DIN rail.
Protection : IP 20
Dimensions: 125 x 75 x 55 mm
ELECTRICAL CONNECTIONS
M-A-I-C
FUNCTIONS
·
·
·
·
·
·
·
Pulse divider
Frequency / current converter
Tachometer
Frequency meter
Totalizer
Flow-rate indication
Batch controller
CONFIGURABLE PARAMETERS
· Password
· Function Type (flowrate/volume;
frequency/pulses;batch)
· Output Type (4-20 mA, 0-10 V, 0-20
mA)
· Flowrate units (L/min., L/h, m3/h)
· Display data refreshment time
· Reading stability (manual or automatic)
· Pulse waiting limit time
· Reading decimal digits
· Temperature sensor amplifier gain
· Pulse/litre rate at pulse output
· Output pulse width
· Batched volume
· Analogic output offset
· Analogic output scan
POWER SUPPLY
PULSE INPUT
PULSE OUTLET (COLLECTOR)
PULSE OUTLET (RELAY)
0-10V ANALOGIC OUTPUT
4-20mA ANALOGIC OUTPUT
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
TWO STAGE METER
CE2000-P
AUT OMAT ON
PRINTER
ENTER
MODE
ZERO
ON
OFF
SENSOR PULSES
PRE-CUT
VALVE
FLOWMETERS
PULSES
SHUT-OFF
VALVE
19
20 ________________________________________________________________________________________________Ultravioleta, Tecnología y Maquinaria
2 STAGES PROGRAMMABLE METER CE-2000-P
INTRODUCCIÓN
SPECIFICATIONS
This serie is specially designed to perform the
most of the packaging processes, dosage, mixtures,
loading and unloading of tanks... for chemical or
petrochemical industry, food industry etc.
· 5 digits 12mm high
· Two stage batching
· 6 led to indicate work mode and state
· Partial totalizar
· 15 digits totalizar
· On/off from keyboard
· External starting
· Programming, pre-contact and pulse factor
The have been strongly built so they are resistant
to those extreme conditions of industry.
They are easy to use and they can be read from
long distance. They are compatible with different
type pulses inputs: REED, NAMUR, NPN,
HALL, ENCODER etc. They can also work with
turbine flowmeters, oval wheel meters or
electromagnetic flowmeters.
performance from keypad
· Data protection against electrical supply failures
· TTL output for printer. 2.400 bauds
· Pulse output open collector
· Maximum frequency input: 500Hz
ELECTRICAL FEATURES AND
CONNECTIONS
· Voltage: 220V dc, consumption 10W
· Auxiliar voltage: 12V ac
· Output:
- Output 1: 220 V DC, 100 W inductive
load
- Output 2: 220 V DC, 100W (optional)
· Input: NAMUR, REED, TRANSISTOR,
NPN
· Ambient operating temperature: 0 – 55ºC
· 12 poles connector
DESCRIPTION OF FRONTAL SIDE
5 DIGITS DISPLAY
KEYPAD
PULSE INPUT INDICATOR
ON/OFF INDICATOR
PROGRAM MODE INDICATOR
ENTER
MANUAL MODE INDICATOR
MODE
ZERO
ON
OFF
SENSOR PULSES
TOTALIZER VALUE INDICATOR
PRE-CONTACT VALUE INDICATOR
CONSTANT VALUE PULSES
KEYPAD DESCRIPTION
ENTER
Key to confirm data input and
select commands
Cursor movement along
digits (left and right)
Keys to change values
(up to increase; down
decrease)
ZERO
ON
OFF
MODE
To reste partial totalizer
to zero
Key to star and stop
manual or program mode
Key to select mode
PULSE INPUT
TWO WIRES
SENSORS
(NAMUR-REED)
1. NEGATIVE
2. POSITIVE
SENSORS POWER
SUPPLY: 12V
20 MA
OUTPUT 2
EXTERNAL
220 V DC
OUTPUT 1
220 V DC
STARTING
1. NEGATIVE
2. INLET
3. POSITIVE
INDUCTOR
CONTACTOR
PUMP
PRECONTACT
(OPTIONAL)
EARTHING
NET 220 V DC
Ultravioleta, Tecnología y Maquinaria______________________________________________________________________________________________
TWO STAGE METER
CE2000-P
FLOWMETERS
PULSES
CONVERTER
PULSES
AUT OMAT ON
PRINTER
PRE-CUT
VALVE (Optional)
SHUT-OFF
PUMP
SHUT-OFF
VALVE
21
Download