Audible Alarm The Safety Of Your Solar Energy System Near At Hand BENEFITS Australian Standards Compliant SolaGRID Audible Alarm complies with the new AS/NZS 5033:2012 Standard (clause 3.4.3) that requires low voltage PV arrays to be equipped with an alarm that alerts the solar user when an earth fault has occurred and is used to initiate corrective action. Visual and Audible Alarm Notification SolaGRID Audible Alarm provides both visual (red flashing light) and audible (beeping – 74 dB @ 1 m) alarm of a fault at the inverter. Geared for Fault Clearance The AS/NZS Standard 5033 stipulates that the external alarm must repeat at least once per hour until the fault is cleared. SolaGRID Audible Alarm goes one better. Although the user can push a mute button to silence the audible alarm, the red light will continue to flash until the fault is cleared. SAFETY FIRST: Solar arrays are generally situated in exposed areas and are subject to environmental and operational conditions (e.g., lightning, vermin, wind, or mechanical impact) that can cause a safety hazard, such as a short-circuit or earth fault. While many solar inverters have local indication that trigger if a fault has occurred, the inverter may be located in a garage, switch room or rooftop where operational staff or a solar system owner may not notice the warning – a dangerous situation potentially leading to electrocution or fire. The SolaGRID Audible Alarm is a compact, lightweight safety device that ensures solar power users are alerted, both through audible and visual alarm, if an earth fault affects an inverter. The unit can be placed in areas near the solar user such as a kitchen or office. SolaGRID Audible Alarm puts the safety of your solar energy system near at hand. Single Alarm Covers Multiple Inverters A single SolaGRID Audible Alarm will track and alert an earth fault from multiple inverters. The user can then check the inverter displays to determine which inverter carries the fault. SMA and Power One Compatible The SolaGRID Audible Alarm is compatible with highest quality inverter products, including Power One and SMA. S P E C I F I C AT I O N S The SolaGRID Audible Alarm is powered from a 230 V AC single-phase control circuit – 1 amp max. It is available as a kit complete with: •SolaGRID Remote Audible Alarm Module •Fully enclosed surface mount enclosure – with 20 mm conduit entry top, bottom or rear •DIN mount 1 pole 10 x 38 mm fuse holder •10 x 38 mm Fuse Cartridge – 1 A •A3 colour wiring diagram Endless Possibilities in Solar Solutions Audible Alarm The Safety Of Your Solar Energy System Near At Hand From the Standard: AS /NZS 5033:2012 Installation and safety requirements for photovoltaic (PV) arrays Clause 3.4.3 Earth fault alarm In systems where the PV array is operating at LV, an earth fault alarm system shall be installed which, on an earth fault, causes an action to be initiated to correct the earth fault. The alarm system is to continue repeating its operation at least at hourly intervals until the earth fault is corrected. The alarm system may be an audible signal placed in an area where operational staff or system owners will be aware of the signal or another form of fault communication, e.g. fax, email, SMS or similar, shall be applied to inform to the system operator. A set of operational instructions shall be provided to the system owner that includes the actions to take when the alarm operates. NOTE: Many inverters have earth fault detection and indication in the form of indicator lights. This indication is generally not in an area that will be noticed. IEC 62109-2 requires that inverters have a local indication and also a means of signalling an earth fault externally. The external alarm function should be used to ‘cause an action to be initiated to correct the earth fault’, i.e. by placing a light or audible signal where it will be noticed. Wiring Diagram The SolaGRID Audible Alarm system is compliant with latest modifications to the AZ/NZS standard governing installation and safety requirements for photovoltaic (PV) arrays. Queensland: 07 3166 9598 • Victoria: 03 9017 1010 • South Australia: 08 8372 7808 • sales@solarinception.com.au www.SolarInception.com.au