CP 50 ELECTROCARDIOGRAPH SPECIFICATIONS Welch Allyn CP 50™ Electrocardiograph Advanced ECG in a compact design that fit your facility and your budget. > > > > > > Offered at an affordable price to help maximize your budget Easy-to-use, with one-button operation, makes performing ECG tests efficient Full-color, touch-screen display to help improve staff satisfaction High-resolution thermal printer provides quick outputs Battery operation lets you easily transport your device to the patient Optional Mobile Stand and Carrying Case are also available CP 50™ ECG • Reliable touch-screen display • Optional MEANS interpretation • High-resolution thermal printer • ‘Instant-on’ button • Internet storage For more information, contact your local Welch Allyn representative or visit www.welchallyn.com/CP50 CP 50™ ECG Plus with Connectivity Includes all of the features of the CP 50, plus • Flexible connectivity options • External printing capability • Programmable patient entry fields CP 50 Technical Specifications Dimensions L x H x W 12.8 in (32.5 cm) x 3.1 in (8 cm) x 7.4 in (18.8 cm) Weight 4.4 lb (2.0 kg) Keyboard type (power, auto ECG, and rhythm ECG buttons) Polyester overlay Display Thermal paper Type TFT, 4.3 in (11 cm) color touch screen Resolution WQVGA, 480 x 272 Z-fold 4.5 in (11.4 cm) x 250 sheets Roll 4.5 in (11.4 cm) x 65.6 ft (20 m) Thermal printer (internal) Computer-controlled dot array, 8 dots/mm Thermal chart paper speeds 10, 25, 50 mm/s Gain settings Lead configurations Report print formats—Internal thermal printer (PCL 3 or 5 only) Report print formats—Compatible External Inkjet or Laser Auto ECGs 2.5, 5, 10, 20 mm/mV, AUTO Rhythm ECGs 2.5, 5, 10, 20 mm/mV Standard, Cabrera Auto ECGs 3x4, 3x4 + 1R, 2x6 Rhythm ECGs 3 leads Average cycles 3x4 + 3R @ 25 mm/s, 3x4 + 3R @ 50 mm/s, 2x6 + 1R @ 25 mm/s, 2x6 + 1R @ 50 mm/s Auto ECGs 3x4, 3x4 + 1R, 2x6 , 3x4 + 3R, 6x2, 2x6, 12x1 Average cycles 3x4 +3R @ 25 mm/s, 3x4 + 3R @ 50 mm/s, 2x6 + 1R @ 25 mm/s, 2x6 + 1R @ 50 mm/s , 3x4 + 2R @ 25 mm/s, 3x4 + 2R @ 50 mm/s, 6x2 + 2R @ 50 mm/s Frequency range 0.3 to 150 Hz Digital sampling rate > 1,000 samples/second/channel Pacemaker detection ANSI/AAMI EC11 Power requirement Universal AC power supply ~110–240 V, ~50/60 Hz, 1.5 A maximum AC fuses Time-log type, 2.0-amp 250-V rating, Littlefuse 0218002P or equivalent Rechargeable battery 10.8 V, 2000 mAh, 3-cells Li-Ion “smart” battery. Recharge time < 3 hours Filters High-performance baseline 0.5 Hz Muscle tremor 35 Hz AC interference 50 Hz or 60 Hz Internal ECG Storage Up to 50 ECGs External ECG Storage Unlimited via USB connection Safety, EMC, and regulatory compliance Standard connectivity ANSI/AAMI EC11* UL60601-1 CAN/CSA C22.2 No. 601.1 IEC/EN 60601-1 CAN/CSA C22.2 No. 601.1.1 IEC/EN 60601-1-1 CAN/CSA C22.2 No. 601.1.2 IEC/EN 60601-1-2 CAN/CSA C22.2 No. 601.1.4 IEC/EN 60601-1-4 CAN/CSA C22.2 No. 601.2.25 IEC/EN 60601-1-6 IEC/EN 60601-2-25 IEC/EN 60601-2-51 (2x6 lead arrangement) Mini USB Client and USB Host (CP 50 Plus version only) Ethernet (CP 50 Plus version only) Connectivity with electronic medical records (CP 50 Plus only) Through the Welch Allyn CardioPerfect™ Workstation software Electrodes Rigorously tested for conductivity, adhesion, and hypoallergenic qualities; exceeds all AAMI standards Power cable Meets or exceeds Type SJT Patient cable and leads Meets or exceeds ANSI/AAMI EC53, EN/IEC 60601-2-25 and EN/IEC 60601-2-51 Environmental operating conditions Environmental storage conditions Temperature +50° F to +104° F (+10° C to +40° C ) Relative humidity 15 - 95% noncondensing (30 - 70% for printing) Atmospheric air-pressure limits 700 – 1060 hPa Temperature -4° F to +122° F (-20° C to +50° C ) Relative humidity 15 - 95% noncondensing Atmospheric air-pressure limits 700 – 1060 hPa Protection against electric shock Class I, internally powered Type BF Mode of operation Continuous * Per AAMI EC11:1991/(R)2001 Diagnostic Electrocardiographic Devices, Section 3.1.2.1 Disclosure of cautionary information/performance characteristics paragraph c) Accuracy of input signal reproduction, the manufacturer shall disclose the methods used to establish overall system error and frequency response. Welch Allyn has used methods A & D, as prescribed in section 3.2.7.2 and 4.2.7.2 of this same standard, to verify overall system error and frequency response. Because of the sampling characteristics and the asynchronism between sample rate and signal rate, digital ECG systems such as the CP 50 may produce a noticeable modulating effect from one cycle to the next, particularly in pediatric recordings. This phenomenon is not physiologic. Specifications are subject to change without notice. Welch Allyn Corporate Headquarters, 4341 State Street Road, Skaneateles Falls, New York 13153 USA (p) +1.800.535.6663 ©2013 Welch Allyn MC10387 COMPREHENSIVE AND PORTABLE ELECTROCARDIOGRAPH ELI 230 12-lead Resting Electrocardiograph PRIMARY BENEFITS: • Portable solution. Compact and lightweight, the ELI™ 230 provides comprehensive functionality in a portable device. • Best 10 technology. Capture the best 10 seconds of ECG data from system memory, reducing the need for repeat ECGs. • Wireless data acquisition. Increase workspace flexibility by acquiring 12-lead data without the need for a tethered cable. VALUE WITHOUT COMPROMISE • Complete functionality in a compact, portable, device. Easy-to-use and feature-rich, the Burdick ELI 230 offers a cost-effective ECG solution with capabilities such as digital sampling, accurate and reliable adult and pediatric ECG interpretation, and full-size printouts. • High-resolution color display provides real-time preview of 3, 8, or 12-leads of ECG data, as well as post-acquisition review of acquired ECG. • VERITAS™ resting ECG interpretation algorithm uses gender specific and adult and pediatric criteria to provide a silent second opinion for diagnostic interpretation. SMALL IN STATURE, BIG IN CAPABILITY • Choose between the innovative WAM™ wireless acquisition module or the AM12™ acquisition module. Both include replaceable lead wires, lead fail indicator, and remote control with buttons for ECG acquisition and rhythm printing. • Our unique Best 10 feature automatically selects and displays the best 10 seconds of ECG data from the memory, reducing clinical review time and reducing the need for repeat ECGs caused by patient movement or other sources of ECG artifact. • Digital sampling technology provides in-depth ECG signal assessment including 40,000 sps per channel for unsurpassed pacemaker spike detection. ELI™ 230 ELECTROCARDIOGRAPH FE ATURE MORTARA INSTRUMENT, INC. MORTARA RANGONI EUROPE, SRL MORTARA INSTRUMENT AUSTRALIA MORTARA DOLBY UK LTD. www.mortara.com ISO 13485 CERTIFIED WARRANTY + SERVICE SPECIFICATION* INSTRUMENT TYPE 12-lead electrocardiograph INPUT CHANNELS Simultaneous acquisition of all 12 leads STANDARD LEADS ACQUIRED I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 WAVEFORM DISPLAY Backlit, 1/4 VGA 320 x 240 LCD color display 4+4 or 6+6 lead presentation INPUT IMPEDANCE INPUT DYNAMIC RANGE ELECTRODE OFFSET TOLERANCE COMMON MODE REJECTION Meets or exceeds the requirements of ANSI/AAMI EC11 PATIENT LEAKAGE CURRENT CHASSIS LEAKAGE CURRENT Meets or exceeds the requirements of ANSI/AAMI ES1 DIGITAL SAMPLING RATE 40,000 s/sec/channel used for pacemaker spike detection; 1000 s/sec/channel used for recording and analysis RESOLUTION 1.875 microvolt LSB A/D CONVERSION 20 bits FREQUENCY RESPONSE 0.05 to 300 Hz FILTERS High-performance baseline filter; AC interference filter 50/60 Hz; low-pass filters 40 Hz, 150 Hz, or 300 Hz LEAD REVERSAL DETECTION Notification of possible lead reversal conditions, for both limb and chest leads, indicated on the display, prior to printing PACEMAKER SPIKE DETECTION Pacemaker spike markers, for both atrial and ventricular rhythms, indicated on printouts OPTIONAL FUNCTIONS Optional Mortara VERITAS resting ECG interpretation with age and gender specific algorithm PAPER Thermal roll paper; 210 mm (8.25”) wide THERMAL PRINTER Computer-controlled dot array; 8 dots/mm THERMAL PRINTER SPEEDS 5, 10, 25, or 50 mm/s GAIN SETTINGS 5, 10, or 20 mm/mV REPORT PRINT FORMATS Standard or Cabrera; 12, 6, or 3+1 channel RHYTHM PRINT FORMATS 12, 6, or 3 channel with configurable lead groups DEVICE CLASSIFICATION Class I, Type CF defibrillation-proof applied parts ECG STORAGE Internal storage up to 20 ECG records; external storage to USB memory stick CONNECTIVITY Review or print from ELI Link V4.xx WEIGHT 5.8 lbs. (2.63 kg) including battery (without paper) DIMENSIONS 11.25 x 7.5 x 2.75" (28.58 x 19 x 7 cm) POWER REQUIREMENTS Universal AC power supply (100-240 VAC at 50/60 Hz) 110 VA; internally rechargeable battery *Specifications subject to change without notice. Mortara®, AM12™, Burdick®, ELI™, VERITAS™, and WAM™ are trademarks or registered trademarks of Mortara Instrument, Inc. Ref: 9513-175-02-ENG Rev 1