CEE MP -15/600 Deadbreak Junction Power System

advertisement
Power System
CEE MP
-15/600 Deadbreak Junction
For 15/25kV,600A
General:
The CEE MP
-15/600 Deadbreak Junction provides two,
three or four 600Amp deadbreak interfaces based together
and encapsulated in a precision molded peroxide cured EPDM
insulated rubber body with a semiconductive outer shield.
Deadbreak Junctions are used in padmount apparatus,underground vaults,and other installations to establish loops,taps
and splices,and facilitate apparatus change-outs.
Sectionalizing a cable run to find and isolate a cable fault
is made easy when a deadbreak junction is used with
deadbreak connectors meeting the requirements of ANSI/IEEE
Standard 386-"Separable Insulated Connector Systems".
CEE MP -15/600
When mated with a comparably rated product,the junction
DeadbreakJunction
provides a fully shielded,submersible threaded connection for
deadbreak operation.
Electrical Characteristics:
Voltage Ratings and Characteristics
DIMENSIONS(mm)
Maximum Rating Phase-to-phase
26.3
Maximum Rating Phase-to-ground
15.2
AC 50 Hz 1 Minute Withstand
42
DC 15 Minute Withstand
78
BIL and Full Wave Crest
125
Minimum Corona Voltage Level
19
5/8¡å
75.5
25
57
Standard Voltage Class
82.5
kV
158
Description
Current Ratings and Characteristics
Description
Amperes
Continuous
600A
24h overload
1000A
Short Time
105
105
A
Branch
2 Branch
3 Branch
4 Branch
180
285
390
50kA rms symmetrical for 0.3s
A
20kA rms symmetrical for 4.0s
Electrical Characteristics are in accordance with or ex-
B
ceed GB/T 12706.4-2002, ANSI/IEEE 386-1995, IEC 60502-
115
115
105
105
6-9x25
3
4:1997.
3- 80
1
Deadbreak Junctionv
2
Red Shipping Cap
3
Silicone Lubricant
4
Cleaning Paper
5
Installation Instruction Sheet
6
Quality certificate
Branch
B
110
135
163
Standard Packaging List:
53
2 Branch 3 Branch 4 Branch
205
310
600A Mounting Bracket
415
Power System
Ordering Information:
CatalogNo
Voltage Rating(kV)
CurrentRating(A)
CEEMP2-15/600
15
600
CEE MP3-15/600
15
600
CEEMP4-15/600
15
600
Code Information:
CEE
MP
-
15
/
600
Current Rating (A)
Voltage Rating (kV)
Branch (2,3 or 4)
Deadbreak Junctionv
China Electric Equipment
Typical Arangement:
Deadbreak Junction +Mounting bracket+Deadbreak Tee connector
+Deadbreak T-IIconnector+elbow conncetor+Insulated protective cap(15kV Class)
234
230
298
165
298
490
254
Important:
¡
All of the 600A spare interface must be covered with 600A Insulated
Protective Cap . Red Shipping Cap
is not for energized operation .
Do not replace the Insulated Protective Cap
with Red Shipping Cap
.
More Information for cable accessories,installation instructions,technic questions,
Please contact your local CEE power system representative or visit our website http://www.
ceepower.com.