SERIES H6 - Plug-in auxiliary relays

advertisement
SERIES H6 - Plug-in auxiliary relays
Plug-in auxiliary relays
Control
circuit
H6AB30
Utilisation
Rated
No of
thermal
contacts
current (Ith)
Cat. no. (1)
Indicator
ON/OFF
Pack Weight
Plug-in faston 2.8 or solder terminals with 2, 3 or 4 contacts
Direct or alternating current
AC
10A
DC
6A
10A
2
3
4
2
3
4
6A
-
H6AB20 ◆
H6AB30 ◆
H6AB40 ◆
H6CB20 ◆
H6CB30 ◆
H6CB40 ◆
6
6
6
6
6
6
0.070
0.070
0.070
0.070
0.070
0.070
H6AA20 ◆
H6AA30 ◆
H6CA20 ◆
H6CA30 ◆
6
6
6
6
0.070
0.070
0.070
0.070
H6AD21
H6AD22
H6AE31
H6AE32
H6CD21
H6CD22
H6CE31
H6CE32
6
6
6
6
6
6
6
6
0.075
0.070
0.075
0.070
0.075
0.070
0.075
0.070
Solder to printed circuit with 2 or 3 contacts
H6AD21
Direct or alternating current
AC
10A
DC
10A
2
3
2
3
-
Plug-in with 8 or 11 pins, with 2 or 3 contacts
Direct or alternating current
With pushbutton operator and relay on/off indicator
AC
H6AE32
DC
8 pins
10A
2
11 pins
10A
3
8 pins
10A
2
11 pins
10A
3
Mechanical
LED
Mechanical
LED
Mechanical
LED
Mechanical
LED
(1) To complete the catalogue number, replace the symbol ◆ by the code corresponding to the voltage and frequency
of the control circuit.
Rated voltages (1)
Alternating current (V)
◆
50Hz
S
6
60Hz
Ohms
5,7
A
6
5
T
12
B
D
24
C
E
F
42
G
48
32
140
48
310
320
H
25
12
20
110
24
80
60
510
D
24
440
E
32
785
F
36
995
G
H
I
J
(2)
48 60 72 110 220
1640 2700 3987 8700
I
J
110
115
110 120
1750 2000
Direct current (V)
◆
DC
Ohms
A
6
28
B
12
110
(2) Use 110V DC coil, with external resistor of 10 kΩ 2W connected in series.
Technical characteristics, see J.31
Dimensions, see J.33
L
125
127
N
220
R
M
P
208 220 240
2580 7700 6000 7000 8000
SERIES H6 - Plug-in auxiliary relays
Accessories
System
H6SZ13BG
Fore use with
No of
contacts
Cat. no.
Pack Weight
2 or 3
H6SZ13BG
6
0.010
4
2 or 3
H6SZ14BG
H6SZ13BA
6
6
0.012
0.010
4
2 or 3
H6SZ14BA
H6SZ13BFT
6
6
0.012
0.065
8 pins, solder terminals
and panel flush fixing
8 pins, front terminals
and panel surface or rail fixing
11 pins, solder terminals
and panel flush fixing
11 pins, front terminals
and panel surface or rail fixing
H6AB20, H6AB30
H6CB20, H6CB30
H6AB40, H6CB40
H6AB20, H6AB30
H6CB20, H6CB30
H6AB40, H6CB40
H6AB20, H6AB30
H6CB20, H6CB30
H6AD21, H6AD22
H6CD21, H6CD22
H6AD21, H6AD22
H6CD21, H6CD22
H6AE31, H6AE32
H6CE31, H6CE32
H6AE31, H6AE32
H6CE31, H6CE32
2
H6SZ12DG
6
0.013
2
H6SZ12DFT
6
0.050
3
H6SZ13EG
6
0.013
3
H6SZ13EFT
6
0.050
System
For use with
Cat. no.
Pack Weight
H6AB20, H6AB30, H6AB40
H6CB20, H6CB30, H6CB40
H6AB20, H6AB30, H6AB40
H6CB20, H6CB30, H6CB40
H6AB20, H6AB30
H6CB20, H6CB30
H6S2A
6
0.008
H6S2B
6
0.005
H6S2C
6
0.010
No of
elements
Cat. no.
Pack Weight
4
6
8
10
14
H6S3B
H6S3C
H6S3D
H6S3E
H6S3G
6
6
6
6
6
Sockets
Solder terminals
Solder to printed circuit
H6SZ12DG
H6SZ13EFT
H6S2B
Front terminals
Mounting plate
Individual to panel
Individual to 35 mm DIN-rail
(EN50022)
Double to 35 mm DIN-rail
(EN50022)
H6S2C
For use with
Support chassis
Assembling in groups. Sockets: H6SZ12DG, H6SZ13EG
Dimensions, see J.34
0.050
0.105
0.155
0.195
0.235
SERIES H6 - Plug-in auxiliary relays - Technical data
H6AB20, H6CB20
H6AB30, H6CB30
H6AA20, H6CA20
H6AA30, H6CA30
H6AB40
H6CB40
H6AD21, H6AD22
H6AE31, H6AE32
H6CD21, H6CD22
H6CE31, H6CE32
Fig. 1 Electrical endurance in AC1
n = number of operations
Ps = Power in kVA
General
250V
Rated insulation voltage (Ui)
Test voltage
IEC 255-1 / IEC 255-0-20
Insulation resistance
Level of insulation to VDE 0110
Ambient
Ambient temperature
conditions
Altitude
Humidity
2000 Vrms
1500 MΩ
Group C - 250V
-25°C to +55°C
2000 m
Without condensation
Control circuit
AC
DC
Rated voltage
50 Hz
(V)
60 Hz
(V)
Voltage limits
Pick up
Drop out
Coil consumption
Sealed
Inrush
Closing time
Opening time
Mechanical endurance
Max. operating rate unloaded
Rated voltages
(V)
Voltage limits
Pick up
Drop out
Coil consumption
Closing time
Opening time
Mechanical endurance
Max. operating rate unloaded
6, 12, 24, 42, 48, 110, 115, 127, 220
6, 12, 24, 32, 48, 60, 110, 120, 208, 220, 240
0.8 to 1.1 xUs
0.3 to 0.6 xUs
2 VA
4.5 VA
8 to 10 ms
4 to 7 ms
20 x 106 Ops.
36,000 Ops/h
6, 12, 24, 32, 36, 48, 60, 72, 110
H6AB40, H6CB40
Fig. 2 Coefficient of reduction of the electrical
endurance as a function of the cos ϕ of the
load
0.8 to 1,1 xUs
0.2 to 0.55 xUs
1.3 W
10 to 13 ms
5 to 7 ms
15 x 106 operations
36,000 operations/hour
Contacts
Rated thermal current Ith ( ␪ < 40°C)
Rated voltage Ue
Maximum operating power
AC cos ␸ = 1
DC
Maximum closing current
Electrical endurance
Operating rate when loaded
10 A
2000 VA
(A)
30 A
Terminal numbering
H6.B20, H6.A20
H6.B30, H6.A30
6
H6.D21, H6.D22
6
H6.E31, H6.E32
H6.B40
9
6A
250V
10 A
1000 VA
2000 VA
See figure 3
10 A
20 A
See figures 1 and 2
1800 operations/hour
Fig. 3 Maximum operating power in DC
= 1 and 2 contacts in series,
non-inductive load
= 1 and 2 contacts in series,
inductive load L/R = 40ms
SERIES H6 - Plug-in auxiliary relays - Dimensions
Relays
Sockets
H6SZ13BG
H6.B20, H6.B30
J
33
H6.A20, H6.A30
H6SZ14BG
H6.B40
H6SZ13BA
H6SZ14BA
H6.D21, H6.D22
H6SZ13BFT
H6.E31, H6.E32
SERIES H6 - Plug-in auxiliary relays - Dimensions
Sockets
J
H6SZ12DG, H6SZ13EG
Fixing system
H6S2A
34
H6SZ12DFT, H6SZ13EFT
Support chassis
H6S2B
Screw B2.2 x 9.5
H6SZ2C
H6S3B
H6S3C
H6S3D
H6S3E
H6S3G
L
85
128
171
214
300
Download