15 th Year Of Excellence amperes Precision Design, Absolute Confidence PUBLIC ADDRESS SYSTEM C O M M E R C I A L I N S TA L L AT I O N S 20 15 16 ISO 9001: 2008 Design & Manufacture of Public Address Equipment and Systems Certificate No. 16895 / A / 0001 / UK / En AMPERES ELECTRONICS SDN BHD (Co No. 509025-X) Organisation Reaching Out Amperes Electronics is now in its 15th years and shall continue to grow for the next few decades. It was started as a sole proprietor and with the promising future, it was incorporated into a Private Limited company ( Sdn Bhd ) in the year 2000. Puchong, a fast growing township near Kuala Lumpur has been the base of operation and for its future expansion. Amperes has been a name synonymous with Public Address Systems. With thousands of references in the region, it is no doubt that Amperes is a brand well accepted. We sincerely express our heartfelt thanks to our loyal clients in our home ground as well as our partners in South East Asia and Middle East countries. We began from a tiny premises and our persistence in pursuing the goal had made the company to grow steadily. From a small workbench, we focus on the mission and can proudly to claim that we are a true entity involved in Research and Development, manufacturing and distribution. With dynamism of growth, our production floor has expanded to many folds since its inception. 15 In order to be a part of institution, we are members of Federation of Malaysian Manufacturer ( FMM ) and Matrade, with " amperes " registered as our trademark. Product th Forward We started from fabricating customised accessories of AV market such as patch panels, selectors, etc. Due to acceptance of our quality workmanship, more and more complicated products were required and hence, it was the opportunity came knocking. As the path ahead never gets easier, Amperes shall endeavour to sail through, producing more technologically advanced and cost effective products for every stake holders. Year Of Excellence Standardised products should be the way to go, thereby ZS601 ; 6 channel speaker zone selector were the first product introduced. We listen and react, seek and apply the shared knowledge to achieve a brand name of “ Precision Design, Absolute Confidence “. From there on, more and more products were developed, based on the requirement of clients and in accordance to British Standards. What we truly emphasise are the suitability of installations, user friendly and keeping the cost at optimum level. Currently, we are able to provide solutions from simple and basic installations to mid and large scale setups. As PA technology advances, we join the race in IP technology. Integrating conventional systems with Ethernet based products. As IP Systems shall be the game in future, Amperes shall invest substantially in developing items in this field. Philosophy & Mission Continuous Product Development policy is the heart of producing excellent and reliable products and is the vital route of placing Amperes in arena of global players. Major portion of revenue is invested in R and D, not only developing new equipment but enhancing present models. Since the certification of ISO9001 : 2008, Amperes had been emphasising the best practices in its management of product and operation, in the goal to achieve a well respected organisation. A Member Of : Fed of Malaysian Manufacturer (FMM) Design & Manufacturing of Public Address Equipment An organisation without a mission is a meaningless journey to travel, and Amperes adopts a simple one : “ Adopting the best organisation practices where possible, producing products of contemporary needs and cost effective yet reliable. “ ISO 9001: 2008 Design & Manufacture of Public Address Equipment and Systems Certificate No. 16895 / A / 0001 / UK / En www.ampereselectronics.com catalogue 2015 : all rights reserved by amperes electronics sdn bhd 1 Introduction iPX5101 iPX5200 iPX5151 iPX5300 iPX5500 2 IP BASED PA SOLUTION IP Based System Ethernet Paging Server Ethernet Music Server Ethernet Paging Client Ethernet Music Client Ethernet Comm. Box PD1240 PD1280 PD2400 PD2800 PD1160 PM1000 PM1060 PM1120 EP1200A 4 CM1400 MICS CD1001 MP1020 MR1301 PT1801 FI6000 5 MxP2188 MxP2188 MxP2288 Tech. Info DA2208 MX2222 6 PA300S QP2000S PA2000S DP2000S MA2000S MC2000S Tech. Info 10 11 12 PAGING MICROPHONE Digital Paging Microphone (Soft Touch Buttons) 24 Zone Digital Paging Microphone (Soft Touch Buttons) 24 Zone Digital Paging Microphone Digital Paging Microphone 8/16 Zone Remote Paging Microphone Desktop Paging Microphone 6 Ch Desktop Paging Microphone 12 Ch Desktop Paging Microphone Emergency Paging Microphone Panel 13 13 14 14 14 15 15 15 16 17 17 18 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 12 Ch Speaker Zone Selector 6 Ch Speaker Zone Selector 12 Ch Speaker Zone Selector 6 Ch Speaker Zone Selector 6 Ch Uninterrupted Paging Speaker Zone Selector Source Selector 8 Ch Decoder / Zone Selector 24 Ch Data Decoder 9 POWER SUPPLIES & DISTRIBUTION BC9740 SQ9715 PS9400 24V DC Automatic Battery Charger Sequential Power Switcher Regulated 24V DC Power Supply 39 39 40 40 41 41 42 43 44 45 45 VOLUME CONTROLLER / PATCH 6 Zone Rack Mounted Volume Controllers Auto Volume Controller 5 / 10 / 30 / 50 / 100 / 150W Volume Controllers 5 / 10 / 30 / 50 / 100W Volume Controllers Speaker Patch Panel 100V - 8 Ohm Speaker Patch Panel VR7600S AV7200 VC7000S VC8000S VP7501 VP7810 46 46 47 47 48 48 SPEAKERS CS Series CS620 / 840 BS / DV410 FS Series CL / CH Series PS / GS SP Series HS Speaker Accessories Tech. info Tech. Info 35 35 36 37 38 38 SELECTORS & DATA DECODER ZS5122 ZS5062 ZS5121 ZS5601 ZS5602 SS6401 TD6080 TD6240 12 POWER AMPLIFIERS 10 / 20 /30W Mini Amplifiers 125 /250 / 375 / 500W Power Amplifiers with AFS 120 / 240 / 360 / 480W Power Amplifiers Multichannel Power Amplifier 60 / 120W Mixer Amplifier with Zone Selection 60 / 120W Basic Mixer Amplifiers Sound Pressure Level 6 Duty / 1 Standby Amplifier Changeover Panel 6 Duty / 1 Standby Manual Changeover Panel 8 Duty / 1 Standby Auto Standby Amplifier Fault Changeover 6 Channel Speaker Line Surveillance Amplifier Surveillance Module 12 Channel Amplifier Monitor Panel 11 MIXERS / DISTRIBUTION 8 x 8 Matrix Paging Controller 8 x 8 Matrix Paging Controller (System Components) 8 x 8 Matrix Paging Controller (Preview) General Terms 2 Input 8 Output Signal Distribution Amplifier Pre-Amplifier Mixer AX700 AC3601 AX3800 LS4600 AS4000 AM4120 10 INPUTS Chime & Siren Tone Generator Microphones CD/MP3/AM-FM Tuner 2 Ch Media Player Message Recorder / Player Weekly Programmable Timer Fire Alarm Interface AMPLIFIER CHANGEOVER & MONITORING 8 SOFTWARE BASED PA SYSTEM PMX II Standard Music Server Software PMX II LAN LAN Based Music Server w. Monitoring Tech. Info Product Selection Guide 3 04 06 07 08 08 09 7 Dual Cone Ceiling Speaker Co-axial Ceiling Speaker Surface Mount Speakers Full Range Speakers Column Speakers Pendant Ball / Ground Speakers Projection Speakers Horn Speaker 49 50 51 52 53 54 55 56 OTHERS Complimentary products Guide to Ceiling Speakers Installation Calculating Battery Capacity 57 58 59 iPX5000 Series amperes IP Based System Introduction IP Based PA System is seeing growth in coming future based on the growing size of installations, expanding complexity of requirement and cost consciousness in connecting large scale sites. Cabling infrastructure can be simplified and reduced and among the important features is the ability for IP system to cater for future expansions without having to relay cables. Amperes iPX5000 offers solution to convert conventional system into IP environment with ease. With continuous development of IP related products, iPX shall not only provide seamless connectivity between systems but would be able to provide real time monitoring and controls with the new Amperes PMX II LAN software. DECENTRALISED PAGING SYSTEM EQUIPMENT MONITORING & CONTROLS IP SOLUTIONS VOICE & EVAC ANNOUNCEMENT TO PA SYSTEM BGM DISTRIBUTIONS Features and Advantages of iPX5000 Series 101010 DUPLEX DIGITAL AUDIO TRANSMISSION DECENTRALIZED SYSTEM Audio signal is transmitted in digital format thereby provides immunity from noise which would normally occur using analogue signal for long distance transmission. Building to building inter connectivity shall be further simplified by using existing IT network whereas in conventional system, a substantial amount of copper cable has to be laid to link to main rack. CHOICE OF CONNECTIVITY EXPANSION & CONVERSION Communications between main paging station to remote can be achieved using local LAN or WAN, Internet or using Fiber Optic Cable (converter required). System can be expanded further to cater for larger area without having to run connecting cablings to the main rack, provided there is a network point in the new location. COST SAVINGS MOBILITY Significant cost savings on cabling works can be achieved by applying IP, especially in large setup such as university, factory and office complexes. With readily available Wifi, the BGM broadcast CPU can be placed anywhere, thus eliminating the limitations of using wired system. REMOTE CONTROLS / MONITORING 4 MULTI LEVEL SYSTEM ACCESS As long as there is a LAN connectivity, paging to remote connection shall be achievable. Among applications include paging to train stations, branch offices or factories. Access to the system operation or setup can be tiered according to different levels via the management software (Available soon). This shall prevent unnecessary interference to the system.source can be broadcasted in the entire setup. MULTIPLE AUDIO BROADCAST INTEGRATION Multiple BGM source can be broadcasted to entire system with each receiving point having flexibility to select the preferred music source. This flexibility shall not be available in conventional system where only a single source can be broadcasted in the entire setup. iPX5000 series can be easily integrated with existing Amperes products such as MatriMix Paging, PMX or PD Series of Paging Microphones. www.ampereselectronics.com iPX5000 Series amperes IP Based System Application in Multi Location Setup Sub Building Network Switch Sub Building Network Switch iPX5300 iPX5300 iPX5151 Music iPX5151 Paging Music Paging PD Mic PD Mic iPX5151 iPX5151 Local PA System Local PA PA System Interconnections between Sub Systems via LAN / Fiber Optic iPX5151 Network Switch iPX5101 iPX5151 iPX5300 Local PA System PD Mic PC WITH PMX II LAN SOFTWARE iPX5200 Main Building (Main System) MP3 CD TUNER Linking multiple locations via Ethernet / LAN allows full controls, cost savings and flexibility in which conventional installations would not be possible. Should cable link to sub system not possible, wireless connections using IP transceiver shall be the option. The main system shall be able to page to desired zone of any of the remote sub system and vice versa. Each system shall work independently regardless of communication continuity with the main rack, thereby reducing communication risk during downtime. Components in IP Paging IP Network Controller IP Music Server IP Communication Box Amperes IP System has been upgraded from its first model and iPX5101 succeeded iPX5100 as the Paging Server or Ethernet Paging Controller. In this version, more clients within a system are allowed and not limited as previously. iPX5200 offers a great way of streaming audio to remote locations via LAN, delivering high quality sound reproduction at the receiving end. It is also known as Network Audio Inserter, enabling analogue audio from players to be fed into the IP network. iPX5500 is used to relay information from various equipments with RS485 and to transmit to PC via Ethernet. Amperes PMX II LAN software with monitoring modules shall be used to monitor or control the remote equipment. IP Paging Client IP Music Client PMX II LAN Software iPX5151 is the Ethernet Paging Client which receives and transmits paging audio and RS486 data from digital paging microphone, which is then fed to PA mixer for amplification. iPX5300, Ethernet Music Client is used to receive audio streaming from central rack either from iPX5200 Ethernet Music Server or via PMX II LAN. Quality sound can be expected as it plays MP3 audio at up to 320 kbps. PMX II V2 is the latest version released, rendering greater flexibility in operating and loaded with extra features including the ease of interfacing with external paging microphones. 5 www.ampereselectronics.com iPX5101 Ethernet Paging Server IP Based System amperes Introduction Technical Specifications Amperes IP System has been upgraded from its first model and iPX5101 succeeded iPX5100 as the Paging Server or Ethernet Paging Controller. In this version, more clients within a system are allowed and not limited as previously. Multicast method is employed, and apart from the number of client, the other main advantage is the transmission speed. Progressive delay in receiving audio and data from Paging Mic are eliminated and every client shall receive the transmission simultaneously. Power requirement : Voltage Current 18 ~ 24V DC (Normal DC 24V) 350 mA Connectivity - LAN interface - Common protocols - Priority protocols RJ-45, 100Mb/s TCP/IP, UDP, IGMP, HTTP UDMP, ADP IPX5101 functions as the traffic controller for all paging clients ( iPX5151 ). Every activity from Clients shall be assessed by the Controller and shall route the transmission to its intended destination. It is used to store various parameters of clients connected to it such as priority level, zone configuration, routing destination, etc. Audio - Analogue input (peak-to-peak) - Input load resistance - Input load capacitance - Total harmonic distortion (THD) - S/N ratio (full scale signal) - Digital format Integration with iPX5151 shall form a complete IP solution to enable paging via Ethernet. Setup process had been made simpler and all are performed via http. Rear View: Firmware upgrade 255 Max (Web Browser) IE V8+, Firefox V22+, Google Crome V25+, RS485 Via Web Browser Operating condition : Temperature Humidity -20°C ~ 80°C 80% Case : Dimension Weight 482 x 44 x 180 mm 1.9 kg Client connection User interface Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.9 kg 1.25Vrms 30 Ohm 100 pF 0.1% 83 dB IMA ADPCM / MP3 (CBR / 320 kbps max) / WAV Application Schematic PD SERIES PAGING MIC amperes ETHERNET iPX ETHER5151 NET PAGIN G CLIEN T ADDRESS LINE BALANCED OUTPUT RESET cat5e / 6 direct or through network iPX5151 ETHERNET iPX5151 iPX amperes ETHERNET ETHER 5151 NET PAGIN G CLIEN T ADDRESS LINE iPX amperes ETHERNET ETHER5151 NET PAGIN G CLIENT ADDRESS BALANCED OUTPUT LINE BALANCED OUTPUT RESET RESET EP1200A EMER. PAGING MIC amperes ETHERNET iPX ETHER5151 NET PAGIN G CLIEN T ADDRESS LINE BALANCED OUTPUT RESET ETHERNET iPX5151 MR1300 MESS. PLAYER iPX5200 MUSIC SERVER MP3 / TUNER / CD MEDIA PLAYER iPX 5 1 0 1 iPX5300 amperes ETHERNET ETHERNET iPX ETHER5300 NET MUSIC ADDRESS CLIENT LINE BALANCED OUTPUT RESET ETHERNET music audio paging audio & data LOCAL PA EQUIPMENT INCL. PRE-AMPLIFIER MIXER ZONE DECODER POWER AMPLIFIERS ETC. NETWORK SWITCH WITH FIBER LINK FROM FIRE ALARM INTERFACE NETWORK SWITCH WITH FIBER LINK ETHERNET iPX5151 iPX5300 amperes ETHERNET iPX ETHER5300 NET MUSIC ADDRESS CLIENT LINE BALANCED OUTPUT RESET ETHERNET music audio paging audio & data LOCAL PA EQUIPMENT INCL. PRE-AMPLIFIER MIXER ZONE DECODER POWER AMPLIFIERS ETC. a m pe re s ACT STATUS REM POWER iPX5101 IP PAGING CONTROLLER MAIN SYSTEM 6 www.ampereselectronics.com Fiber redundant loop ( not available to all switchers ) SUB SYSTEM iPX5200 Ethernet Music Server amperes IP Based System Introduction Network Audio Inserter SD Card Slot LAN Environment Features 4 analogue line inputs and 1 SD card BGM sources for audio streaming via LAN Connectivity of up to 255 iPX5300 music clients Client groupings into 8 for easy broadcast destination selection Ease of programming / configuration via http page High quality audio encoding and transmission iPX5200 offers a great way of streaming audio to remote locations via LAN, delivering high quality sound reproduction at the receiving end. It is also known as Network Audio Inserter, enabling analogue audio from players to be fed into the IP network. With its multiple analogue inputs and SD card reader, user shall be able to select the channel desired and stream them to individual or group of music clients of their choice. Eight groups are available, with each group consisting of up to 32 clients. Setting of various parameters shall be through http, and status of each client can be directly monitored at real time. iPX5200 is indeed an outstanding tool for LAN audio streaming at reasonable cost, suitable for varsities, office buildings, club houses, hotels etc. Rear View: DC 24V ETHERNET ADDRESS : + - Multiformat audio file transmission and decoding ETHERNET ON/OFF Quality Product From AMPERES ELECTRONICS LEFT RESET IPX 5200 SERIAL NO : microSD ETHERNET MUSIC SERVER RIGHT 100mA Connection to WIFI router for wireless transmission Application Schematic Technical Specifications DUAL CHANNEL DIGITAL MEDIA PLAYER Connectivity - LAN interface - Common protocols - Priority Protocols Audio - Analogue input (peak-to-peak) - Input load resistance - Input load capacitance - Total harmonic distortion (THD) - S/N ratio (full scale signal) - Digital format CH 2 FM a m pe re s OFF/ON Power requirement : Voltage Current CH 1 FM MP 1020 / V- / V+ MODE MIN MAX MIN MAX OFF/ON / V- / V+ MODE MP1020 Analogue Inputs 18 ~ 30V DC (Normal DC 24V) <100 mA STREMING UP NEXT DOWN PRE SOURCE IPX 5200 1 2 3 4 5 6 7 CD1001 8 amperes POW START / STOP RJ-45, 100Mb/s TCP/IP, UDP, IGMP, HTTP UDMP, ADP 1.25Vrms 30 Ohm 100 pF 0.1% 83 dB IMA ADPCM / MP3 (CBR / 320 kbps max) / WAV microSD (SD Card Input) amp eres iPX5200 iPX ETHE RNET MUSIC CLIENT GROUP ETHERNET MUSIC SERVER ADD 53 ETHE 00 RNET MU RESS SIC LAN LINE NCEDUT BALA OUTP CLIEN T LOCATION N RESET ETHE RNET iPX5300 Music Client LOCATION 1 amp eres iPX ETHE RNET ADD 53 ETHE 00 RNET MU RESS SIC LINE NCEDUT BALA OUTP CLIEN T RESET Firmware upgrade 255 Max (Web Browser) IE V8+, Firefox V22+, Google Crome V25+, RS485 Via Web Browser Operating condition : Temperature Humidity -20°C ~ 80°C 0 - 70% Case : Dimension Weight 482 x 44 x 180 mm 1.9 kg Client connection User interface Local PA System RNET ETHE iPX5300 Music Client LOCATION 2 Local PA System Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.9 kg 7 www.ampereselectronics.com iPX5000 Series IP Based System amperes iPX5300 iPX5151 Ethernet Music Client Ethernet Paging Client Introduction Introduction iPX5151 is the Ethernet Paging Client which receives and transmits paging audio and RS486 data from digital paging microphone, which is then fed to PA mixer for amplification. iPX5300, Ethernet Music Client is used to receive audio streaming from central rack either from iPX5200 Ethernet Music Server or via PMX II LAN. Quality sound can be expected as it plays MP3 audio at up to 320 kbps. iPX5151 replaces iPX5150 with a totally improvised architectures, notably on the operational protocol and size reduction. Multicast transmission is now employed, enabling it to send audio or data at faster rate and the quantity of clients in a network can be up to 255 units. The application of iPX5300 is rather simple, as depicted in the diagram in page 7 (iPX5200). It shall be installed at remote buildings and its balanced audio output shall be fed to mixer and thereafter amplifiers. Settings of each module is through http for bass and treble, volume, ID, etc. Parameter settings is done using http, connected directly to the unit for channel setup, bass and treble controls, volume, etc. Technical Specifications iPX5151 12 ~ 24V DC (Normal DC 24V) <100 mA Connectivity - LAN Interface - Common Protocols - Priority Protocols RJ-45, 100Mb/s TCP/IP, UDP, IGMP, HTTP UDMP, ADP Audio - Analogue in/out (peak-to-peak) - Input load resistance - Input load Capacitance - Total harmonic distortion (THD) - S/N ratio (full scale signal) - Digital format User interface Firmware upgrade Packing information Qty per carton : 1 unit WxHxD : iPX5151 / iPX5300 : 168 x 102 x 190 mm Weight 8 : iPX5151 / iPX5300 : 1 kg www.ampereselectronics.com iPX5300 Power Requirement : Voltage Current Operating condition : Temperature Humidity Case : Dimension (WxHxD) Weight 1.25Vrms 30 Ohm 100 pF 0.1% 83 dB IMA ADPCM / MP3 (CBR / 320 kbps max) / WAV (Web Browser) IE V8+, Firefox V22+, Google Crome V25+, RS485 Via Web Browser -20°C ~ 80°C 0 - 70% 100 x 147 x 40 mm 300 g iPX5500 IP Communication Box amperes IP Based System Introduction iPX5500 is the communication interface for equipment with RS485 outputs and remote PC, enabling remote monitoring and controls via Amperes PMX II LAN software. It converts RS485 data received from equipment into IP and shall be received by remote PC in the LAN environment. Likewise for remote controlling, user would be able to perform setting or changing parameters via the software modules available in PMX II LAN. Among devices available are QP Series of amplifiers, LS4600 line surveillance unit, AX3800 auto amplifier changeover panel and PS9400 battery charger. The list shall be expanded further in due time. With combination of iPX devices available, user shall have better controls and monitoring of PA equipment to ensure smooth running with minimal downtime, especially during emergency. Features Converts UART interface to IP for monitoring and controls via LAN Application Schematic Birectional RS485 data communication Up to 16 devices per comm box PC WITH PMX II LAN SOFTWARE Compatible with other UART devices Simple setup via http Management Room NETWORK SWITCH Technical Specifications CONNECTION VIA LAN OR FIBER Control Room Rack NETWORK SWITCH TO OTHER iPX DEVICES QP POWER AMPLIFIERS iPX5500 COMM INTERFACE RS485 / UART CONNECTIONS Power requirement : Voltage Current 12~ 24V DC (Normal DC 24V) <100 mA Connectivity - LAN interface - Common protocols RJ-45, 100Mb/s TCP/IP, UDP, IGMP, HTTP Firmware upgrade (Web Browser) IE V8+, Firefox V22+, Google Crome V25+, RS485 Via Web Browser Operating condition : Temperature Humidity -20°C ~ 80°C 0 - 70% Case : Dimension (WxHxD) Weight 200 x 120 x 30 mm 600 g User interface QP POWER AMPLIFIERS LS4600 LINE SURVEILLANCE PS9400 BATTERY CHARGER FI6000 PHASE CONTROLLER Packing information Qty per carton : 2 unit WxHxD : 512 x 83 x 288 mm Weight : 1.55 kg PT1801 TIMER 9 www.ampereselectronics.com PMX II V2 Software Media Playback Music Server Software Media Library amperes Calendar Scheduling Emergency Call PMX II is software that consists of virtual hardware components such as Music Player, Music Storage, Programmable Timer, Message Player and Paging Station. It is a standalone version and runs on PC with operating system of Windows 7 and above. With a converter as dongle, the audio and control outputs from PC shall be fed to conventional PA rack, enriching the entire installation to a more sophisticated setup. Main Page The user interface had been made to be user friendly, enabling smoother setup and viewing. The system shall be able to integrate freely with existing equipment such as zone decoders, paging microphones with different priority level and emergency paging panel which the activities would be monitored in the screen. Among suitable installations includes offices, transportation stations, malls, hotels, schools, etc. Media Library Features Media playback module to feed BGM audio to PA system for MP3, WAV or other supported audio files by Windows Media Player. Media Library to store unlimited songs, messages, tones or chimes in HDD for playback Weekly programmable timer allows repetitive playback of tones or chimes Calendar scheduling to playback songs such as birthday songs Controls up to 256 zones which is linked to external zone selector such as ZS5121 via TD6240 Zone configuration allows naming each zone to specific name and assignable as Normal or Emergency zone. Paging or messaging to zone or groups of zones, with priority overriding for Emergency Call PC Paging Interface Application Schematic PC MIC PM1000 PAGING MIC PC PC audio output PMX6500 External Device Status Audio + Data (2 pair screen) USB output Other audio inputs Lower priority setting Audio CH1 CH2 CH3 CH4 CH5 CH6 SOURCE E X T IN P U T OFF M A S TE R TON E CTRL MX 2122 S E LE C T TUNER OFF M IN M IN MAX M IN S IG IN MAX S IG IN M IN MAX M IN S IG IN MAX S IG IN M IN MAX S IG IN M IN S IG IN MAX M IN MAX M AX C H IM E M IN POW ER I CASS CD AUX M AX M IX E R T R E B LE BASS M IN S IG IN a m pe r e s O MAX M U S IC S O U R C E S IG IN MX2222 MIXER TD6240 DECODER a m pe r e s AMPLIFIER PD2400 / PD2800 POW ER M ENU Q P 2 5 00 Higher priority Audio + Data (2 pair screen) I a m pe r e s O UP DOWN 5 0 0 W 1 0 0 V L IN E P O W E R A M P LIFIE R Switching signal ZONE SELECTOR ZS 5121 a m pe r e s O V E R R ID E 10 www.ampereselectronics.com 1 2 3 4 5 6 7 SPEAKER ZONE SELECT 8 9 10 11 12 ALL CALL SPEAKERS Stand alone setup of PMX II PMX II Xtended LAN Based PMX System amperes Software Application Schematic PMX II LAN version has all the features of PMX II standalone but it runs on LAN environment and would be able to work with other Amperes IP products such as Music Client, Communication Box and soon the IP MatriMix. In addition, it contains the extension modules of equipment User Interface, such as QP2000, FI6000, AX3800 and other upcoming models which would be available for free updates. With the extension modules, user shall be able to control and monitor status of equipment from multiple locations within the local area network. Among them, controlling the volume control of power amplifiers, fault changeover notifications, emergency paging activation alert and so forth. Application of these extensions would require the usage of iPX5500 communication box, which receives RS485 data from equipment and send to the PMX software and vice versa. With the advent of IP technology in PA systems, PMX II LAN would be the essential component sought after and it is a cost efficient way to an advanced paging system. Paging Mic PC with PMX II (1) Paging Mic PC with PMX II (2) LAN System (1) System (2) iP Client Music Client iP Client iP - UART Communication interface iPX5500 Components in PMX II LAN Paging and message Click to access paging control panel Combox Manager: Interfacing to external equipment for monitoring and control Client Info : Showing music clients connected to system Scheduling Events / messages scheduled for playback Playback Controls : Control buttons for music playback System message: Status of PMX communication Emergency Paging Status : Indications for emergency paging in progress Playlist : List of messages or songs for playback PACKING INFO: - Software CD - PMX II stand alone only:- PMX6500 USB to RS485 converter WxHxD : 190 x 168 x 102 mm Weight : 1.05 kg PMX IP Info : Information of PMX IP address HARDWARE REQUIREMENT : PC with 4GB RAM ( higher RAM required for simultaneous multichannel music playback ) with Windows 7 / 8 operating system. Intel i3 and above processor or equivalent recommended. 11 www.ampereselectronics.com PRODUCT SELECTION GUIDE Amperes has variance of products to choose from for practically almost applications, be it a simple mixer amp or more complex audio distributions with multiple building blocks. SQ 9715 The table below provides a quick equipment selection guide. As quantity or product type may vary for different applications, such as size, budget or customer’s requirement, you are welcomed to contact us for free consultation. AM 4120 CD 1001 a An l g lo ic s Ba ue at IP M No MODEL 1 iPX5101 √ √ √ √ 2 iPX5151 √ √ √ √ 3 iPX5200 √ √ √ √ 4 5 iPX5300 √ √ √ √ √ 6 PD2000 Series / PD1160 √ √ √ 7 PD1240 / PD1280 √ √ √ 8 EP1200A √ √ √ √ 9 CM1400 √ √ √ √ √ √ √ √ √ √ √ √ √ √ PM1000 Series √ d se rix ita g Di I O Ba √ CM 1400 FIRE BP 2000 10 CD1001 / MP1020 11 MR1300 / MR1301 12 TD6240 / TD6080 √ √ √ 13 PT1800 / PT1801 √ √ √ √ 14 FI6000 √ √ PMX Systems √ √ √ √ √ 15 16 MxP2188 / MxP2288 √ √ 17 ER1108 √ √ 18 RP1104 / 1105 √ 19 MX2222 √ √ √ √ √ 20 DA2208 √ √ √ √ 21 QP2000 Series √ √ √ √ 22 PA2000 Series MA / MC2000 √ √ √ 23 √ 24 PA310 / 320 / 330 √ √ √ √ √ √ 25 AX3800 √ √ √ √ 26 AX700 √ √ √ √ 27 AS4000 √ √ √ 28 AC3601 √ √ √ 29 AM4120 √ √ 30 31 LS4600 ZS5601 / 5121 / 5602 √ √ √ √ √ √ √ 32 SS6401 √ √ √ √ 33 SQ9715 √ √ √ 34 35 BC9730 / BC9740 √ √ √ √ √ √ √ √ √ √ √ √ PS9400 √ √ √ √ √ 36 VR7600 √ √ √ 37 AV7200 √ √ √ √ √ 38 VC7000 / 8000 √ √ √ √ √ 39 VP7501 / 7810 √ √ √ √ √ √ BP 1000 IPx 5100 TD 6240 TD 6080 MxP 2188 ER 1108 MX 2222 DA 2208 √ √ SS 6401 ZS 5601 ZS 5121 ZS 5602 PT 1800 MSG 2 MR 1300 a m pe re s LS 4600 VR 7600 AC 3601 AX 700 Basic setup : restaurants, meeting rooms, lecture halls, mobile PA Analogue : small buildings, offices, entertainment outlets, schools Digital : medium size or high rise buildings exceeding 12 zones, hypermarkets, university / college campus Matrix : Bungalows, club houses, entertainment centre, offices which require flexible music selection IP System : Large scale installations with multiple blocks, remote installations, transportation hub or stations, universities, etc AMP. NORMAL AX 3800 AMP. FAULT PILOT TONE AMP. CHANGEOVER AMP. NUMBER amperes STANDBY AMP. FAULT 1 2 3 4 5 6 7 8 PS 9400 PREV ENTER MENU NEXT POWER BC 9740 CHARGING amperes FAULT PA 2480 AUTOMATIC BATTERY CHARGER PA 2480 BC 9730 MA 2024 VP 1000 MA 2012 VP 3000 MC 2112 Product outline drawings can be downloaded from our website Precision Design, Absolute Confidence QP 2000 www.ampereselectronics.com PD1000 Series amperes Digital Paging Mic PD1240 | 24 Zone Digital Paging Microphone PD1280 | Digital Paging Microphone Sensor Touch Multipoint Paging Priority Introduction Features Sensor touch keypad with impressive outlooks PD1240 and 1280 are enhanced versions of the popular PD2000 series incorporating soft touch buttons and improved sound quality. All essential features such as Priority level assignment, multipoint paging, illuminated gooseneck microphone and volume controls are included. LED indicators for PD1240 and large LCD display for PD1280 Suitable for multipoint paging with priority level setup Improved sound output PD1240 is a 24 buttons zone control with 4 fixed groups with ALL CALL, suitable for small setup. For larger installations of up to 254 zones, PD1280 shall fit into the requirement which comes with large LCD panel and programmable 9 priority levels. Built in chime Adjustable volume controls for chime and microphone Name setting at PD1280 Compatible with Matrix Controller and TD Series of Zone Decoders, IP Client iPX5151 PD1280 PD1240 Application Schematic Technical Specifications PD1240 Operating voltage Power consumption Zone selection Switching selection Microphone Output impedance Output level Output controls Data connections Cabling to decoder Recommended operating distance Compatible interfacing device Chime Indicators Displays Frequency response S / N ratio Gooseneck mic length Dimension (W x H x D) Weight PD1280 24V DC via EX2800 with local power adaptor 1.2 W 1.3 W 24 zone keys, Numerical keypad with Group, All Call Group, All Call Sensor touch keypad Gooseneck condenser capsule ; unidirectional 600 Ohm 1.2V balanced line output Chime, mic volume RS485; 19.2 kbps 2 pair screen; 22 AWG / Cat 5e decoder 500m subjected to cable size MxP2188, TD6240, TD6080 4 tone up and 4 tone down Zone, power, audio, data, gooseneck ring LED NIL LCD display; white back illumination 100 - 12 kHz >65 dB @ 1 KHz 400 mm 230 x 192 x 65 mm ( Excluding Mic) 1.6 kg At remote location PD1240 Mic Nbr 2 12V DC via adaptor Cat 5e EX2800 PD1240 Mic Nbr 1 12V DC via adaptor EX2800 Cat 5e PD1240 Mic Nbr 3 EX2800 2 pair screen cable Cat 5e TD6240 Zone Decoder (24 channel) MX2222 Pre-amplifier Mixer 8 core cable ( Cat 5 ) connection via RJ45 Jack Power Amplifier Each cable to cater for 6 zones ZS5121 Spk Zone Selector (Zone 1 to 12) ZS5121 Spk Zone Selector (Zone 13 to 24) Speakers 13 www.ampereselectronics.com PD Series amperes Digital Paging Mic 24 Zone Digital Paging Microphone | PD2400 Digital Paging Microphone | PD2800 8/16 Zone Remote Paging Microphone | PD1160 Grouping PD2800 Priority These classic digital paging microphones are suitable for remote paging setup over long distance, typically within 500m. With their harmonised protocols, they are compatible with all TD decoders and Matrix controller via RS485 data. With multipoint paging of several PD mic, user shall be able to set priority level of each mic according to the priority needs, allowing unit with higher priority to override lesser one. It is suitable for large scale installations of up to 256 zones, enabling 9 groupings of 12 zones each. Features including : Programmable zone grouping ie. Storing selected zones in groups to enable faster access to paging. 9 priority level settings ie. Enables 9 multipoint paging station with 9 levels of priority LCD display for easy monitoring PD2400 PD1160 It is suitable for mid-size installations of up to 24 zones. Among its distinctive features include : 24 direct zone key with 4 groups with ALL CALL. Built in 4 tone chime with Chime and Mic volume controls Up to 3 priority level setting It is a simple and dedicated paging microphone for connection to MxP2188 MatriMix system with 8 / 16 zones call station. Multipoint paging with EX1102 mic extender Technical Specifications Power requirement Power consumption Zone selection Microphone Output impedance Output level Output controls Data output Data connection Operating distance (data) Audio distance Chime Indicators Frequency response S/N ratio Gooseneck mic length Dimensions (WxHxD) Weight 14 www.ampereselectronics.com Direct connection to MxP2188 controller. PD2400 PD2800 24V DC via RJ45 connected to EX2800 170 mA 420 mA 24 individual zone key Numerical keypad 4 groups (preset of 6 zones) ALL CALL Condenser microphone cardioid 600 Ohm balanced 1.2 V (line output) Chime and mic level RS485; 19.2 KBs RJ45 to EX2800 via Cat 5E / 6 cable ; 2P screen to decoder Up to 1000 m (sub. to cable size) Typ 500 m (sub to cable size) 4 tone up and 4 tone down 2 or 4 tones; assignable LCD Display Mic ring, zone switch 100 ~ 12 KHz > 60 dB at 1 KHz 400 mm 292 x 62 x 186 mm (body only) 1.3 kg (excl. adaptor) PD1160 24V DC via MxP2188 800 mA 8 / 16 zone keys with ALL CALL Mic level RJ45 to MxP2188 300 m 300 m - Power, source, volume, busy 150 x 186 x 62 mm (body only) 1.0 kg PM1000 Series amperes Analogue Paging Mic PM1000 | Dekstop Paging Microphone PM1060 | 6 Ch Dekstop Paging Microphone PM1120 | 12 Ch Dekstop Paging Microphone Introduction Features PM1000 analogue series are available in three variants and had been serving many installations faithfully since its creation. They are available as simple paging mic with chime to those with 6 or 12 zone selections. They are most suitable for simple and small size installations of less than 12 zones in total. Condenser gooseneck microphone with illuminated ring Pre and post announcement 4 tone chime Adjustable chime and mic volume with balance mic / line output level Output level selection to mic or line signal to suit the input type of the pre-amplifier mixer Dry contact available when mic is active (PM1000 only) Technical Specifications 6 or 12 zone selection for PM1060 and PM1120 PM1000 PM1060 PM1120 24V DC via D9 conn. 24V DC adaptor 150 mA 150 mA 50 mA ALL CALL 6 and 12 zones w ALL CALL Condenser microphone cardioid 600 Ohm 1.2 V (line output) / balanced mic (775 mV ) Power requirement Power consumption Zone selection Microphone Output impedance Output level Output dry contact Output controls Audio connection Switching connection Operating distance Chime Indicators Frequency response S/N ratio Gooseneck mic length Dimensions (WxHxD) Weight 3 A normally open Chime and mic level 1/4 " stereo phone jack D15 connector 2W connector 300 m (recommended) 4 tone up and 4 tone down Mic ring, zone switch, ALL CALL PM1000 100 ~ 12 KHz (+/- 3dB ; 0 dB out) > 60 dB 400 mm 150 x 62 x 186 mm (excluding mic) 800 gms 800 gms 850 gms PM1060 Application Schematic PAGING MIC Audio : 2C screen MIXER OFF CH1 CH2 CH3 CH4 CH5 CH6 SOURCE TUNER MIN MAX SIG IN MIN MAX SIG IN MIN MAX MIN SIG IN MAX SIG IN MIN MAX SIG IN MIN SIG IN MAX MIN MAX MAX CHIME MIN PM1120 POWER TONE CTRL OFF MIN POWER PM1000 Via adaptor, PM1060 / 1120 via D conn SELECT MASTER EXT INPUT MX 2222 I CASS CD amperes O AUX MAX MIXER TREBLE BASS SIG IN MIN MAX SIG IN MUSIC SOURCE E/M PAGING MIC TEST FIRE SIREN ACTIVATE AM 6000 POWER amperes POWER AMP PA 2060 60 Watts POWER POWER AM 6000 I PROTECT O SIGNAL -10 dB amperes CLIP SIGNAL -40 dB Zone Control : PM1000 - 2C for all call, PM1060 / 1120 8 / 16 core ZONE SELECTOR ZS 5121 amperes OVERRIDE 1 2 3 4 5 6 7 SPEAKER ZONE SELECT 8 9 10 11 12 ALL CALL TO LINE SURVEILLANCE / VOLUME CONTROLLER / SPEAKERS Packing information Qty per carton : 1 unit WxHxD : 512 x 83 x 288 mm Weight : PM 1000 - 1.5 kg ( incl adaptor ) : PM 1060 - 1.15 kg : PM 1120 - 1.2 kg Rear View Of PM1000 Rear View Of PM1060 / PM1120 15 www.ampereselectronics.com EP1200A Paging Microphones Siren Tone Activation Emergency Paging Panel amperes RS485 Interface Introduction Emergency Paging Panel is an essential tool for firemen during emergency, allowing direct paging to all zones and bypassing any active BGM or paging in progress. EP1200A is enhanced with communication port, enabling the unit to be used with iPX5151 IP Client for a LAN based setup. This shall allow simultaneous emergency paging or siren activation for entire multiple sub racks available in the system. Features Built in siren tone generator (constant signal) Visual FIRE indicator External voice message activation Dual mode siren tone activation Dry contact when paging mic is activated Priority paging via front panel microphone, bypassing all other audio sources Output level controls for siren and message / paging microphone Application Schematic Application in conventional system MX2222 OFF CH1 CH2 CH3 CH4 CH5 CH6 SOURCE TUNER MIN MAX MIN SIG IN MAX MIN SIG IN MAX SIG IN MIN MAX SIG IN MIN SIG IN MAX MIN MAX MAX CHIME MIN TREBLE BASS MIN O MUSIC SOURCE line out line EP1200A amperes AUX MAX SIG IN a m pe re s MESSAGE RECORDER I CASS CD MAX MIXER SIG IN contact MSG 2 MR 1300 MAX POWER TONE CTRL OFF MIN MIN SIG IN TRIGGER SWITCH SELECT MASTER EXT INPUT MX 2222 FIRE all call activation POWER AMP POWER PA 2480 amperes PROTECT CLIP SIGNAL -10 dB SIGNAL -40 dB PUBLIC ADDRESS POWER AMPLIFIER 100V SPEAKER ZONE SELECTORS ZS 5121 1 2 3 4 5 6 7 SPEAKER ZONE SELECT 8 9 10 11 12 16 24V DC 3.5W MICROPHONE Mic sensitivity Impedance Frequency response -72 dB Omni directional 600 Ohm 300 ~ 8 KHz SIREN Siren frequency Siren duration Siren activation Continuous at 8 KHz Continuous when activated Front test switch / remote contact Input channel Output level Priority sequence Indicators Dimension (WxHxD) Weight Pre-amplifier output, message recorder Balanced line out (1.2V) Paging mic - siren - message - pre amp in Front FIRE with backlight illumination 482 x 88 x 180 mm 3.0 kg ALL CALL Rear View: 24V O/R www.ampereselectronics.com Power requirement Power consumption amperes OVERRIDE VOLUME CONTROLS Technical Specifications SPEAKERS Packing information Qty per carton : 1 unit WxHxD : 560 x 165 x 295 mm Weight : 3.6 kg CM1400 Input Sources Chime and Siren Tone Generator amperes Features Introduction Selectable output as balanced or unbalanced line CM1400 offers 5 chimes and 2 siren tones with selectable balanced and unbalanced line output. Activation of chime shall be from front switches or via remote triggering terminal, enabling the unit to be linked to external sensors or triggering system such as alarm panel, remote mic or emergency switch. Siren has priority over chimes. Front panel switch activation or via remote trigger port It is suitable for installation in schools, factories, hazardous areas etc. 5 types of chimes and 2 siren Adjustable output volume * Customised tones available upon request. Application Schematic Rear View: RELAY OUTPUT CONTACT MELODY a m pe r e s E/M SWITCH contact NO contact SIREN CM 1400 PT1800 WAVY 4T UP 4T DWN 2T UP WEST'R Technical Specifications BELL amperes POWER CHIME / SIREN TONE GENERATOR chime input OFF SELECT POWER MASTER EXT INPUT CH1 MX 2122 CH2 CH3 CH4 CH5 CH6 TONE CTRL TUNER OFF MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX I SOURCE MIN MIN SIG IN MIN MAX MAX CHIME SIG IN MIN CASS CD MAX MIXER TREBLE BASS MIN SIG IN Other Inputs AUX O MAX MUSIC SOURCE CM1400 Operating voltage Power consumption Chime type MX2222 line out Siren type E/M PANEL FIRE External activation Output Output impedance Gain Dimensions (WxHxD) Weight To power amplifier and speakers Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.15 kg 24V DC ; 0.5 A 0.3 A 4 tone up, 4 tone down, 2 tone Ringing bell, Westminster Constant siren 8 KHz Wavy siren Dry contact Line 1V 10 K Ohm +4 dB max 482 x 44 x 180 mm 1.55 kg MICROPHONES Condenser Gooseneck Mic | GM 8 / GM 9 Handheld Compact Mic | GM338 Condenser Tie Clip Mic | TC122 GM8 GM9 Condenser Gooseneck Mic Condenser Gooseneck Mic GM338 Handheld Compact Mic TC122 Condenser Tie Clip Mic Technical Specifications GM8 Capsule Polar pattern Frequency response Sensitivity Output impedance Power supply Dimension Weight GM9 GM338 Back electret condenser Uni directional 20Hz ~ 1.6kHz & 200Hz ~ 20kHz 50 ~ 16 KHz 82 ± 3 dB -45 dB ± dB 1 K Ohm 50 Ohm 9 ~ 12V DC Phantom power supply 400 mm 495 mm 120 x 63 mm 60 gm 90 gm 190 gm TC122 50 ~ 16 KHz -45 dB ± dB 600 Ohm 7.8 dia x 25 mm 40 gm 17 www.ampereselectronics.com Media Players amperes Input Sources CD1001 is a rack mounted integrated CD / MP3 / AM FM tuner media player built specifically to serve BGM requirement in your PA installation. Local listening is available with headphone jack or via the built in speaker. Features USB Plays various format of CD audio, AM / FM tuner and MP3 via USB CD AM / FM Headphone Headphone jack and monitor output for pre-broadcast listening CD1001 CD / MP3 / AM-FM Tuner MP1020 2 CH Media Player MP1020 is a two channel digital media player in a single rack unit. Both the modules operate independently and shall be able to play files from SD Card, USB as well as receiving FM audio. Features Dual channel BGM source in a box Plays files from SD card, USB drive and FM radio reception Rear View CD1001: Headphone monitoring Packing information Qty per carton : 1 unit WxHxD : 560 x 165 x 295 mm Weight : 5.35 kg MP1020 2 CH DIGITAL MEDIA PLAYER Rear View MP1020: CH. 2 CH. 1 CH. 2 CH. 1 LEFT OFF/ON RIGHT ANTENNA AUX OUTPUT LINE INPUT Technical Specifications MP1020 18 Operating voltage Power consumption Playback media Supported files Aux audio input Audio output Output voltage Dimension (W x H x D) Weight www.ampereselectronics.com Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.2 kg CD1001 24V DC 1A 180mA USB, mini SD Card, FM radio MP3, WAV RCA Stereo Line In RCA Stereo LINE Out 1.2V unbalanced 482 x 44 x 180 mm 1.8 kg Playback system CD / CD-R / CD-RW / MP3 / Tuner CD / USB Frequency response S/N ratio Channel separation Noise Distortion 20 - 20 KHz 70 dB > 45 dB 4 mV < 0.5% TUNER Tuner frequency S/N ratio AM : 522 - 1620 KHz FM : 87.5 - 108 MHz 55 dB Audio output Output jack Headphone output Headphone volume Working temperature Power supply Power consumption Dimensions (WxHxD) Weight 500 mV Stereo, RCA jack 1/4” phone jack Via front VC, +4 dB gain 45ËšC 230 - 240V ac 1.8W at 240V ac 482 x 88 x 180 mm 4.4 kg MR1301 Input Sources Message Recorder / Player amperes Introduction ARM 32 bit Processor MP3 Quality 16GB Memory PC Interface The all new MR1301 has loads of features for flexibility in operation and performance for any demanding applications which runs on 32 bit ARM processor. It supports larger SD Card memory size of up to 16GB, offering flexible file / message arrangement or naming. 32 bit ARM chip for faster and multitasking processing of data User shall be able to group different messages with delays in between for every single message bank with high quality MP3 format of 320 kbps. All settings can be done easily, offline through the SD Card and the configurator software provided. Another key feature is the auto firmware updates, making MR1301 a tool that would work to contemporary needs. Up to 16GB of memory space using Micro SD card Rear View: Features Message playback via front direct access button and rear remote triggering DC 24V + High quality MP3 playback of up to 320 kbps 64 kbps IMA ADPCM voice recording for better clarity Flexible message configuration in every memory bank eg. Multiple files in a single button Application Schematic Priority message playback with dry contact activation Playback controls ie. Volume, Repeat, Bass and Treble RS485 output with PC link for remote monitoring or using iPX5400 UART-IP converter for monitoring and control via LAN ( Application software : PMX II LAN ) Auto firmware update / detection upon power up Alternative setup at PC via “MR1301 configuration” software External Contacts for Message Triggering ( Up to 16 contacts ) NOTE: Only Voltage free contacts allowed for remote triggering Alternative Bypass : Audio and Trigger direct to EP1200A Balanced Audio ( line in ) CH1 Technical Specifications Operating voltage Power comsumption Data communication Inputs Processor Message trigger File format MP3 quality Voice recording Files in single bank Delay set up in playback Priority message cut Software interface Remote view / control Indicators Memory Dimension (W x H x D) Weight 24V DC 1W RS485 at 19.2 kbps Line inputs; unbalanced via RCA jack Microphone input; via front phone jack 32 bit ARM 16 front and rear message MP3, WMA, WAV 320 kbps IMA ADPCM 16 KHz Sampling Rate Bit Rate : 64 kbps Up to 20 per message / button Yes Yes Yes Yes LED at switches, LCD display MicroSD up to 16 GB 482 x 44 x 180 mm 2 kg Note : With direct connection to EP1200A, message shall bypass audio signal from MX2222 with higher priority MR1301 MESSAGE RECORDER / PLAYER CH2 CH3 CH4 CH5 MX2222 CH6 SO URCE E X T IN P U T TON E CTRL OFF M ASTER MX 2222 SELECT TUNER OFF M IN M IN MAX M IN S IG IN MAX S IG IN M IN MAX S IG IN M IN MAX S IG IN M IN S IG IN MAX M IN MAX S IG IN M IN MAX M AX C H IM E M IN PO W ER CASS CD amperes AUX M AX M IX E R T R E B LE S IG IN Bal. Audio to Pre-Amp input BASS M IN S IG IN M AX M U S IC S O U R C E EP1200A FIRE Amp input AMPLIFIERS PA 2120 120 Watts PO W ER POW ER PA 2120 PROTECT I C L IP O a m pe re s S IG N A L -10 dB S IG N A L -40 dB 100V Output 24V Override Trigger to ALL CALL Conn. O V E R R ID E ZS5121 a m pe re s O V E R R ID E 2 x 100V Audio 2 x 24V Override VC VOLUME CONTROLLERS SPEAKERS The above diagram shows typical schematic using MR1301 as message player, either for general repetitive message playback or for emergency voice evacuation purpose. Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.6 kg 19 www.ampereselectronics.com PT1801 Multichannel Programmable Timer Inputs Sources Weekly & Event Date PC Interface Clock Backup amperes Built In Chime Introduction Features The all new PT1801 now packed with better features, notably with its setup or programming process. The user friendly “PT1801 Configurator” software is available for download from website and programming of schedules, upload or recall programs can be done at breeze. 8 output triggering ports with user selectable contact options PT1801 is useful for schools, factories, malls, etc. which shall work to provide reliable time reminders for various events of the day. Its 250 programmable steps with 8 output contacts shall cater for needs of various industries. RS485 data for remote monitoring COM COM UNBALANCE LINE OUT OUTPUT LEVEL RELAY DRY CONTACT Application Schematic Optional PC Interface PAGING MICROPHONE ( Normal / Zone Selection ) Audio Output (Balanced / Unbalanced ) OFF CH1 CH2 CH3 CH4 CH5 CH6 SOURCE SELECT TUNER MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN MAX MAX CHIME MIN Audio output ( unbalanced ) TONE CTRL OFF MIN MIN SIG IN POWER MASTER EXT INPUT MX 2222 Zone Triggering Westminster chime output with adjustable volume CH8 NO COM CH7 NO COM CH6 NO COM CH5 NO COM COM CH4 NO COM CH3 NO CH2 NO CH1 NO + User interface software for ease of programming Technical Specifications Rear View: DC 24V 250 preset triggering times with free assignment to any of the output ports PRE-AMPLIFIER MIXER TREBLE BASS MIN SIG IN I CASS CD MAX MIXER SIG IN MAX MUSIC SOURCE amperes AUX O Only when Ch.8 is used Mini USB Cable RELAY OUTPUT CONTACT MELODY a m pe r e s PT1801 POWER AMPLIFIER Input voltage Power consumption 24V DC ; 0.5A 4.8W Output channels 8 Triggering mode ON, OFF, pulse (3 seconds) Memory 250 preset time Contact rating 3A Indicators LED for triggered channel, Melody, Standby Output chime Westminster (Ch. 8 only) Chime output level Line level ; 1.2Vrms Volume attenuation Output connection off to 0 dB 1/4” phone jack ; unbalanced Impedance 1K Ohm Clock backup CR1220 button battery RTC accuracy Data link ± 2ppm RS485 Baud rate Dimensions (WxHxD) 19.2 kbps 482 x 44 x 180 mm Weight 2 kg Zone Triggering ( optional ) or connect to Message Playback equipment SPEAKER ZONE SELECTOR Speakers Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.5 kg 20 www.ampereselectronics.com FI6000 Input Sources Fire Alarm Interface amperes Scalable Integration Phased Evacuation Programmable PC Interface Introduction Features FI6000 is a phase evacuation controller which can be integrated with various Amperes equipment such as zone decoder and voice message player for interfacing with Fire Alarm System. Integration with Amperes products via RS485 interface and Fire Alarm System via dry contacts As part of requirement of EN54, it is necessary that voice alarm to be broadcasted according to zone(s) for orderly evacuation or warning purposes. FI6000 performs the task required by triggering appropriate announcement and intended broadcast zones. Easily programmable for phased evacuation announcement Available in 24 zone per panel and scalable to cater for larger number of zones Provided with FI6000 Configurator software for easier setup Bicolour LED for easier status indication for each incoming sensors FI6000 can be configured via configurator software and is flexible in its setup. Technical Specifications Rear View: Application Schematic PD SERIES PAGING MIC INPUT SOURCES FROM FIRE ALARM INTERFACE / BAS SENSORS ( VOLTAGE FREE ) amperes MX2222 PRE AMPLIFIER MIXER CH1 CH2 OFF CH3 CH4 CH5 CH6 SOURCE SELECT TONE CTRL TUNER OFF MIN MIN MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX SIG IN EP1200A MIN MAX SIG IN MIN MAX SIG IN MIN POWER MASTER EXT INPUT MX 2222 MAX MAX CHIME MIN I CASS O AUX CD MAX MIXER TREBLE BASS SIG IN MIN audio amperes MAX SIG IN MUSIC SOURCE VC 24V trigger USB RESET SNOOZE STOP INPUT & OUTPUT CH1 CH2 FI 6000 amperes CH3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 CH4 RELAY OUTPUT FIRE ALARM INTERFACE Input : Operating voltage Current source idle Current source channel and relay trigger Power consumption idle USB input Communication control Baud rate Unit cascade control Channel input Software configuration 24V DC 20mA 0.10A 0.48W USB to RS485 Driver RS485 19200 bps Software Control 24 Channel FI6000 Configurator Output : Channel output Contact rating LED indicator 4 Channel 3A 28 LEDs Case : Dimension Weight 482 x 44 x 180 mm 1.85 kg EMERGENCY PAGING PANEL EMERGENCY PAGING EMERGENCY / SIREN ACTIVE EP 1200A SIREN MIC amperes FIRE contact 2 to 4 (trigger EP 24V override) audio AMPLIFIER POWER MENU QP2500 I trigger contact ( s ) amperes O UP Quantum 500W 100V LINE POWER AMPLIFIER audio RS485 data DOWN 2000 SERIES 100V audio TD6240 data & audio PRIORITY 2 DATA ACTIVE PRIORITY 1 amperes trigger switching & 100V line audio 1 2 3 4 5 VC 24V trigger 6 7 8 9 10 11 OVERRIDE 12 ALL CALL amperes OVERRIDE SPEAKER ZONE SELECTOR MR 1301 PAGING ZONE SELECTION ENTER MENU UP NEXT SHIFT MSG 1 MSG 2 MSG 3 MSG 4 MSG 5 MSG 6 MSG 7 MSG 8 REC MIC INPUT amperes REC MESSAGE REC / PLAYER 24 CH DATA DECODER / RECEIVER ZS 5121 MR1300 / 1 DOWN PRE POWER TD 6240 DIRECT MESSAGE TRIGGER audio out to MX2222 or EP1200A Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.5 kg TO SPEAKERS 18 21 www.ampereselectronics.com MxP2188 Mixer / Distribution Matrimix Paging System amperes Technical Specifications Introduction Matrix Controller MxP2188 offers flexibility of routing input sources to the output zones, as in many cases that different area of listening would have its own preference to the type of music. It is a 8 x 8 controller but expandable to larger setup of 128 zones. Configuration Power source Inputs Offices, club houses, shopping complexes, entertainment centers as well as high end residential buildings are among places where it is suitable to apply MxP2188. Essential functions such as emergency overriding, remote zone selection and audio monitoring are integral features of the unit, thus making it a suitable equipment in the PA setup. Input connections Input volume control Bass and treble control Phantom power Priority input Chime Message recording Output Zone selection Features 8 input and 8 output Matrix controller with inputs of either Mic or BGM or fed from remote source panel. Individual channel setup for bass, treble and volume. Built in chime with selectable 2 or 4 tone output. Built in voice recorder of up to 60 seconds. E/M override contact Audio monitor via Communication Remote triggering Audio output monitor for every zone. Remote triggering port for message and siren. Priority override dry contact port whenever ALL CALL is triggered. Microphone input for paging at rack. Remote paging desk connectivity to Amperes PD Series of paging microphones Dimensions (WxHxD) Weight Link to Emergency Paging mic / EVAC voice message unit to comply with emergency voice playing requirement. Rear View: 8 x 8 ; Cascade to 8 x 128 24V DC ; 2A via adaptor 8 local BGM - unbal. line or 8 remote BGM via RP1105 1 remote paging mic PD1160 1 local mic input RJ45 (remote) / RCA jack XLR for local mic input Manual adj. at each channel +12 dB to -12 dB ; digital select 12V DC (local mic in only) Local page, E/M message 2 or 4 tone built in 60 secs max in single bank 8 x balanced line output Remote paging mic (PD1160) ; Front panel with ALL CALL 3A dry contact Source monitor with volume control 3W speaker RS485 ; 19.2 Kbps Siren (ALL CALL) Message (ALL CALL / individual) 482 x 88 x 300 mm 6.0 kg IP setup possible by using iPX5150 to enable longer or multi building communication. BGM 2 Application Schematic PD1160 / PD2400 or PD2800 PAGING MIC EP1200A EMERGENCY PAGING PANEL FIRE EX1102 MIC EXTENDER F RO M PD IC S PL IT M A STER MxP2188 TER TO SL AMPLIFIER ZONE 1 1160 TO M AVE AX3800 C/OVER UP MENU amperes L IN E V O LU M E DOWN SPEAKERS L IN E 8 M IC PILOT TONE RP1104 REM OTE CO NTRO L PANEL R E M O TE S O U R C E P A N E L STANDBY AMP. FAULT M IC Cat 5e/6 REM OTE CO NTRO L PANEL R E M O TE S O U R C E P A N E L M O N ITO R S P E A K E R RP1105 DYNAMIC MIC DOWN 5 6 MENU 7 UP V O LU M E 3 4 CD PLAYER RP1104 REM OTE CO NTRO L PANEL UP 22 www.ampereselectronics.com MENU DOWN MENU DOWN UP MENU DOWN Cat 5e/6 Multiple unit looping ER1108 MATRIX O/RIDE PANEL AMP. FAULT AMP. NUMBER AMP. NORMAL UP REM OTE CO NTRO L PANEL AX 3800 ER1108 8 x8 M A T R IX M IX E R M atrim ix P aging MxP 2188 REM OTE CO NTRO L PANEL AMP. CHANGEOVER 1 2 CB110 MIC AMPLIFIER ZONE 8 STANDBY AMPLIFIER Equipment shown are for illustration of a full system. Some items may not be required for simpler setup. Please consult us for larger system requiring multiple units in cascade mode. MxP2188 Mixer / Distribution Matrix Components amperes RP1104 - Remote Zone Control Panel RP1105 - Remote Source Input Panel A remote zone controller with sensor touch buttons which allows the user to select input music source, volume and tones. It shall be installed at remote location at individual zone and connected to the MxP2188 controller via Cat5e / 6 UTP cable. Each controller shall run individually to each input port of the respective zone. It is used as a local source panel where microphone or line source from music player can be patched to the controller. RP1104 Remote Zone Control Panel shall be installed side by side with RP1105 to provide power source. The localized input source shall be bypassed if emergency paging is activated at the controller. Among installations that require RP1105 shall be promotion area at shopping centers, function rooms, etc. Power source Power consumption Communication Controls Cabling Distance Dimensions (WxH) Weight 24V DC via MxP2188 100 mA RS485 ; 19.2 Kbps Volume / BGM source / tone controls Cat 5E / 6 Up to 500m 86 x 86 mm 100 g Power source Power consumption Communication Controls Inputs Cabling Distance Dimensions (WxH) Weight 24V DC via MxP2188 100 mA RS485 ; 19.2 Kbps Volume Mic or Line (unbal.), mini jack Cat 5E / 6 Up to 500m 86 x 86 mm 100 g ER1108 - Matrix Overriding ER1108 is an 8 in / 8 out relay panel which would override all individual audio signal from Matrix controller and re-route the outputs to a single emergency source such as EP1200A emergency paging panel. It is an optional item, and shall be installed after the Matrix controller with outputs to individual amplifier of each zone. EP1200A shall be used with emergency trigger and audio output connected to this unit. PD1160 - 8/16 Zone Remote Paging Microphone EX1103 - Paging Mic Extender When multipoint paging is required, EX1103 shall be used, with each PD1160 connected in series in a single circuit. The mic nearest to the Matrix controller shall have priority over its precedence. It is a simple and dedicated paging microphone for connection to MxP2188 MatriMix system with 8 / 16 zones call station. - Multipoint paging with EX1102 mic extender - Direct connection to MxP2188 controller. Power requirement Power consumption Zone selection Data connection Operating distance (data) Audio distance Indicators Dimensions (WxHxD) Weight 18 24V DC via MxP2188 800 mA 8 / 16 zone keys with ALL CALL RJ45 300 m 300 m Power, source, volume, busy 150 x 186 x 62 mm (body only) 1.0 kg 23 www.ampereselectronics.com Matrixmix MxP2288 8 x 8 Marix Paging Controller review available in 2016 Introduction Network ready Multiple Inputs jacks MxP2288 shall be another pride of Amperes, an all new successor of the popular MxP2188. With a decade long experience in providing matrix solution to PA system, we had incorporated various features and improving the shortcomings of the previous version. MxP2288 does not only offer simplified interconnectivity with its associated equipment but minimizing equipment count for the similar functionalities. A summary of features listed shall provide a better glimpse of what it can offer. amperes HTTP acces PMX II LAN compatible Trusted throughout the years, Amperes will continue to deliver cost effective and affordable solutions, uncompromising quality and reliability. Simplified setup The new MxP2288 setting a new benchmark for matrix paging installation. FIRE Matrimix Paging 8x8 MATRIX MIXER MxP 2288 amperes A simplified integration with EP1200A Key Features 24 NETWORKING MADE AVAILABLE As IT features are now inevitable part of PA system, MxP2288 is now ready with network capability. It is now easier to install in IP environment for inter building connectivity and not forgetting the remote viewing and controls the system. The configuration tasks shall be conveniently managed via http. FUTURE EXPANSION With the host of features available for now and thoughts for thereafter, MxP2288 would be able to cater and upgraded for future needs. Firmware and software would be easily updated when new functions are available, and we provide them at no extra cost. SYSTEM COST DOWN Interfacing with EP1200A or adding a paging mic at rack has been simplified and ER1108 is no longer required. Not only the interconnectivity links are reduced but the number of accessories use, which is translated into cost reduction. SMOOTH TRANSITION Similarities for setup, operation and key features are carefully reserved in MxP2288, enabling smoother transition from old to new. AUDIO INPUT SOURCE MxP2288 breaks the limitation on the input source connections and types. Now feel free to insert any source, be it mic or line level, balanced or unbalanced. MULTIPLE JACK AUDIO INPUT SOURCE At times, audio source may have different output jacks, and we make it easier for connections by providing combo jacks, which allow 1/4" phone jacks or XLR Male for plugins. CASCADING Stacking up several controllers to larger setup is now a breeze. Cascading ports are provided for the purpose and signal degradation is no longer an issue as every link ports are now buffered. It means lesser cable mess and audio signal distributor shall not be required. INTEGRATION WITH PMX II LAN Apart from webpage setting of various parameters, integration with PMX II LAN would be made available for much easier access, control and monitor every MxP2288 installed. User would be able to stream music directly from remote PC, making the overall system truly flexible. www.ampereselectronics.com amperes Technical Info GENERAL TERM USED IN PUBLIC ADDRESS SYSTEMS SOUND LEVEL COMPARISON CHART ROOT MEANS SQUARE (RMS) : Average value of ac voltage, it is 0.707 time of the peak voltage of a constant sine wave. IMPEDANCE (Ohm with symbol Z) : A measurement of total resistance to current in a circuit with inductance and capacitance, such as speakers and microphones. The value differs for different frequencies, and thereby would normally be rated at Ohm @ 1 KHz. Machine Gun 130 120 Power tools Hard Rock Band 110 Heavy city traffic Average Home Hi-Fi Level 90 Vacuum Cleaner Average Automobile 70 SIGNAL TO NOISE RATIO ( S/N Ratio ) : Measured in dB, is the ratio of signal to noise at same point of signal. It is normally measured at 1 kHz with 1V input signal. Higher S/N ratio is always preferred. Room with window air conditioner Average Home 50 DECIBELS ( dB ) : Use to express the ratio between two signals, such as Voltage, Power, Current, etc. It is expressed in dB SPL for Sound Pressure Level, dBV for relativity to 1V and etc. Quiet Conversation Broadcast Studio 30 Human Breath Anechoic Chamber 10 SENSITIVITY : The minimum signal required for producing a fixed output level and is specified in various terms. In Microphones ( mV/Pa), is amount of mV produced by a Pascal of sound pressure ( 94 dB ) in axis with the transducer. In Speakers ( dB, 1W @ 1m ) is the sound output in dB produced by 1W of power and measured in axis of 1 m away. In professional Amplifiers ( dBu or V ) is the input signal required for the power amplifier to reach its rated output. SOUND PRESSURE LEVEL ( SPL ) : A measurement of loudness in relation to the threshold of human hearing at 2 uBar. It varies with frequencies and thereby in audio, it is expressed as RMS value in dB SPL. See also the SPL chart. TOTAL HARMONIC DISTORTIONS ( THD ) : Expressed in %, it is the ratio of a fundamental frequency to the level of all harmonic frequencies produced by the equipment. Lower percentage is better. FREQUENCY RESPONSE : Is used to indicate how well an equipment or speaker response to the audio input signal, usually 20 to 20 KHz. It is usually measured at 1KHz reference, 1V input level with +/- 3 dB. BALANCED SIGNAL : Refers to cable carrying audio signal with 3 conductors ie. Hot, Cold and Ground or Shield. It offers better immunity against external interference and is preferred choice for long cabling. UNBALANCED SIGNAL : Refers to audio signal in cable with Hot and Ground (Shield) conductors. It is recommended for short distance cabling as it is subjected to interference. SPEECH TRANSMISSION INDEX ( STI ) : STI is used to measure speech intelligibility by injecting a test signal at source point and measurement is made at the listening plane. The measured value is within the range of 0 to 1. 0 18 140 STI 0.3 0.45 0.6 0.75 1.0 100 80 60 40 20 0 Turbo Propeller Plane at take-off Threshold of pain thunder Heavy Thunder Subway Banging Steel Plate Alarm Clock Average Factory Background Music Average Office Voice, low Quiet Home Whisper Watch Ticking Threshold of hearing 0.0002 Dyne/Sq. cm Sound Pressure Level ( SPL ) is normally expressed in dB, in relation to the lowest sound level a human ear can hear ie. 20 uBar. The chart below shows typical SPL level from various source of sound. AUDIO LEVELS : In professional audio, line level is referred to as +4 dBU which is a reference of how much it is above or below the reference level of 0.775V. 4 dBU = 1.25V rms. The value of consumer or semi-professional differs and is lower than this, eg. 0 dBV = 1 V rms. Consumer line level is typically -10dBV or 0.32V. 0.775V rms is used as reference as it is used to generate 1 mW ( 0 dBm ) over the load of 600 Ohms. ( P = V2 / R ). TERMS RELATED TO SPEAKER POWER AVERAGE POWER : Often referred to RMS Power as rms value of voltage and currernt are used to calculate the power. PROGRAM POWER : Also known as Music Power and is normally twice the amount of Average Power. It is used to select suitable amplifier rating. PEAK POWER : Defines the instantaneous power delivered to speaker at highest level of output. 25 www.ampereselectronics.com DA2208 Mixer / Distribution Distribution Amplifier amperes Introduction DA2208 shall be used to amplify incoming audio signal of line level and thereafter linked to several amplifiers to avoid sound distortion. It consists of 2 sets of 1 in 4 out configuration and can be set as 1 in 8 out format. Each output channel has its individual bass and treble controls, facilitating tone setup of the amplifier to suit the type of speakers used as well as the acoustic environment. Rear View: Dual Mode Tone Controls Features Operates as dual channel 1 input 4 output or single channel 1 input 8 output Individual bass and treble control with volume adjustment Direct input signal to output whenever DC power input not available or whenever power failure occurs Technical Specifications Operating voltage Power consumption Configuration Input level Input impedance Output gain Output impedance Controls Frequency response Dimensions (WxHxD) Weight 24V DC 2.4W 1 in x 8 out or 2 in x 4 out Line : 1V rms max 10 K Ohm + 4 dBu 10 K Ohm Bass, Treble, Channel volume 150 ~ 19 KHz (+/- 3 dB at 1 KHz) 482 x 44 x 180 mm 1.55 kg Application Schematic MX2222 MIXER Paging audio signal ( Bal ) BGM audio signal ( Bal ) DA2208 DIST. AMPLIFIER Balanced output Amplifiers for signal input 1 with output from Ch 1 to 4, Serves as Paging amplifiers PA 2120 1 20 W atts POW ER POW ER PA 2120 I PROTECT O S IG N A L -1 0 dB C LIP S IG N A L -4 0 dB AMP ( PAGING ) PA 2120 1 20 W atts POW ER POW ER PA 2120 Amplifiers for signal input 2 with output from ch. 5 to 8 Serves as BGM amplifiers I PROTECT O S IG N A L -1 0 dB C LIP S IG N A L -4 0 dB PA 2120 1 20 W atts POW ER POW ER PA 2120 I PROTECT O S IG N A L -1 0 dB C LIP S IG N A L -4 0 dB AMP ( BGM ) PA 2120 1 20 W atts POW ER POW ER PA 2120 Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.15 kg 26 www.ampereselectronics.com I PROTECT O S IG N A L -1 0 dB C LIP S IG N A L -4 0 dB The above illustration is for Uninterrupted Paging setup. In normal setup with single input, use the link switch to form 1 input 8 outputs configuration. Each output from DA2208 can be linked up to 6 power amplifiers. MX2222 Mixer / Distribution Pre-Amplifier Mixer amperes Introduction Priority Mute Dual Output Phatom Power Features 12 inputs of mic, BGM sources, ext.chime and mixer link Expandable to form more channels for larger setup Auto mic muting with adjustable mixing level for mic Ch.1, 2, ext.chime and mixer link This compact 1 hu pre-amplifier mixer features 6 mic, 4 BGM sources, chime and external line inputs and is suitable for any application, such as meeting room, lecture theatre, hall of prayer and definitely commercial fixed PA installation. It dual output feature can be used for uninterrupted paging setup, ie. BGM and paging announcement. Adjustable priority muting level is available for paging announcement to override BGM and other lower priority sources. Adjusting it to minimum and the unit shall work like any other mixing unit and it comes with 12V phantom power supply for mic input 1 to 4. Application Schematic PM1000 MICROPHONE Priority muting with disable option for normal mixing mode Switchable phantom power for mic channel 1 to 4 Dual output ; mixed line and BGM output for uninterrupted paging setup PM1060 MICROPHONE AUDIO SOURCES Independently adjustable BGM output level with balanced line MX2222 OFF Built in daisy chain source selector with last selection memory CH1 CH2 CH3 CH4 CH5 CH6 SOURCE TUNER SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN to ZS remote trigger AC and DC operation for uninterrupted operation during power failure MAX MIN MAX SIG IN MIN MAX SIG IN MIN POWER TONE CTRL OFF MIN MIN Bass and treble tone control SELECT MASTER EXT INPUT MX 2222 MAX MAX CHIME SIG IN MIN CASS CD AUX MAX MIXER TREBLE BASS MIN MAX SIG IN MUSIC SOURCE line out (mixed) line out (BGM) MIC TEST SIREN ACTIVATE AM 6000 POWER FIRE EP1200 AMPLIFIER - BGM line PA 2120 120 Watts POWER POWER PA 2120 Technical Specification I PROTECT O SIGNAL -10 dB CLIP SIGNAL -40 dB AMPLIFIER - PAGING PA 2120 120 Watts POWER POWER Operating voltage Power consumption Input channels Input impedance Sensitivity(1.2 mVrms output) Output level Output impedance Controls Phantom power Frequency response S/N ratio Dimensions (WxHxD) Weight 230 / 240V ac or 24V DC 2.4W on 240V ac / 100 mA on 24V DC 6 x mic ; 4 x BGM ; ext chime in ; mixer link Mic : 600 Ohm BGM : 47 K Ohm unbalanced Chime input : 10 K Ohm unbalanced Mixer link : 600 Ohm balanced Line : 530 mVrms Mic : 2.5 mVrms 1.2V XLR balanced (mixed output) 1.0V phone jack balanced (BGM output) 600 Ohm balanced Mic channel ; chime ; mixer input Master mixed ; BGM ; Bass and treble controls 12V DC switchable at mic 1 to 4 175 - 15 KHz (+/- 3 dB at 1 KHz) with low cut > 60 dB at 1 KHz 482 x 44 x 180 mm 2.5 kg PA 2120 I PROTECT O SIGNAL -10 dB CLIP SIGNAL -40 dB zone remote trigger fr paging mic ZONE SEL ZS5602 paging BGM TO SPEAKERS Illustration for uninterrupted paging system. Rear View Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 3.1 kg 27 www.ampereselectronics.com PA300 Series Mini Amplifiers Power Amplifiers amperes 20W 4 Ohm Mini Amplifier | PA320 30W 100V Line Amplifier | PA330 Introduction Amperes PA320 is a mini amplifier used to amplify BGM signal to a speaker of 4 or 8 Ohm, such as from TV output to a bathroom speaker in a hotel room. Amperes VC7805 volume controller and VP7810 BGM-Speaker patch panel can be installed if required to allow emergency paging to be announced at the speaker. Other applications include simple mic calling system at counters or as an amplifier module to some other system which need to broadcast audio output to a speaker, ie. queue management system or telephone intercom. Features PA320 Available in 20W 4 Ohm rating or 30W 100V line (PA330) Adjustable volume control for volume preset Compact size for easy installations Application Schematic 24VDC Overriding (optional) PA320 8 Ohm Output SPEAKERVOLUME 2 1 OFF 3 4 5 OVERRIDE amperes 20W 4 OHM Audio VC7810 8 OHM VOLUME CONTROLLER VP7810 OVERRIDING UNIT 230 / 240V ac TV WITH AUDIO OUTPUT BATHROOM SPEAKER (8 OHM WITHOUT TRANSFORMER) PA330 Amperes PA330 has higher rating of 30W 100V line which accepts unbalanced line input. It can be used as remote amplifier in a decentralised PA system. Among applications include classroom paging and paging for remote station. Packing information PA320 WxHxD : 560 x 165 x 295 mm Qty per carton : 20 unit Weight : 16.4 kg Using LC1000 (step down module) shall allow PA330 to accept 100V line input and thereby a very large network of paging can be implemented in a wider area. PA330 WxHxD : 560 x 430 x 225 mm Qty per carton : 10 unit Weight : 24.1 kg Technical Specifications Rating Operating voltage Current consumption Input signal Input sensitivity Max input Input impedance Frequency response Controls Dimensions (WxHxD) Weight 28 www.ampereselectronics.com PA320 20W 4 Ohm 0.14A 230 ~ 240V ac PA330 30W 100V Line Mono ; unbalanced line 40 mV 1.2V 0.17A 10 K Ohm 100 K Ohm 150 ~ 15 KHz 100 ~ 18 KHz (+/- 3 dB) Input volume preset 160 x 95 x 170 mm 130 x 55 x 95 mm 2.4 kg 790 g Power Amplifiers 125W 100V 250W 100V 375W 100V 500W 100V Introduction Application Schematic QP Series are available from 125W to 500W 100V line in 2 hu height, with enhanced circuitry for higher efficiency, better frequency response and with extra protection features. It is digitally controlled and thus enable the unit to be monitored and controlled remotely via RS485. They can be linked to PMX II Xtended* software for remote setting and monitoring, enabling control flexibility for the user. POW ER MX2222 MIXER I | | | | audio signal QP2000 DUTY AMPLIFIER POW ER M ENU Q P2500 I O UP O QP2125 QP2250 QP2375 QP2500 QP2000 Series Power Amplifier With AFS amperes DOW N 5 0 0 W 1 0 0 V L IN E P O W E R A M P LIF IE R M ENU M AX M IX ER M IN E XT IN P U T MAX M IN UP DOW N 5 0 0 W 1 0 0 V L IN E P O W E R A M P LIF IE R M IN 100V Line Standby Output S IG IN POW ER UP S IG IN CH4 I O MAX M IN M ENU Q P2500 MAX M IN CH5 MAX S IG IN CH6 MAX M IN 100V S IG IN SOURCE I O C H IM E M AX T R E BLE TON E CTRL B A SS M IN M A S TE R S IG IN MAX OFF OFF TUNER CD CASS S ELEC T M U S IC S O U R C E AUX 100V POW ER Q P2500 S IG IN MAX M IN CH3 DOW N 5 0 0 W 1 0 0 V L IN E P O W E R A M P LIF IE R M IN MX 2122 S IG IN CH1 MAX M IN CH2 100V S IG IN Inputs Another distinctive feature is its Auto Fault Sensor ( AFS ) circuitry which auto detects faulty output of the unit and would enable a dry contact to initiate an alarm for fault. The internal Fault Standby Changeover relay would allow a faulty unit to be taken over by a standby amplifier if one of the duty amplifiers failed. A feature that reduces the equipment count in the system as well as reducing cabling complexity. POW ER M ENU Q P2500 I O UP DOW N 5 0 0 W 1 0 0 V L IN E P O W E R A M P LIF IE R STANDBY AMPLIFIER Features Available in 125 / 250 / 375 / 500W 100V line output in compact 2hu height Remote Zone Control SPEAKER ZONE SELECTOR ZS 5121 O V E R R ID E 1 2 3 4 5 6 7 SPEAKER ZONE SELECT 8 9 10 11 12 ALL CALL Digital setting for various control features such as bass, treble, fan speed, etc Built in Auto Fault Sensor and Changeover relay for standby fault changeover TO SPEAKERS RS485 data port for remote monitoring Fan speed option ensures longer lifespan of the unit Overload, thermal cut off, short circuit and fuse protections High efficiency for lower power consumption and lesser back up battery capacity Packing information Qty per carton : 1 unit WxHxD : QP2125 / QP2250 / QP2375 / QP2500 : 550 x 180 x 465 mm Weight Technical Specifications QP2375 QP2250 230 / 240V ac or 24V DC back up supply 580VA (2.4A) 290VA (1.0A) 440VA (1.8A) 20A 8A 15A 0.32A 0.3A 0.31A 1V / 10 K ohm; balanced via XLR female -40 to 0 dB 375W 125W 250W 38.7V 22.3V 31.6V 27 Ohm 80 Ohm 40 Ohm 70 Hz - 15 KHz @ 1 KHz +/- 3 dB >70 dB @ 1 KHz, 1V <0.18 % Thermal, Short circuit, Overload, Fuse 75 Deg C Auto temperature controlled fan speed with auto on LCD with temp, audio level and address RS485, 19.2 kbps Internal Pilot Tone, Detection at 15 to 25 secs at 10 secs intervals Standby amplifier relay activation, fault dry contact 482 x 88 x 335 mm 16.5 kg 12.3 kg 13.5 kg QP2125 Power requirement Power consumption (240V ac) Current consumption (24VDC) Standby current (24VDC) Input signal Input gain control Rated output (100V, RMS) 4 ohm output voltage Output impedance (max load) Frequency response S/N ratio THD + N Protections Cut off temperature Cooling system Indications Communication Fault sensing Fault detection response Dimension (W x H x D) Net Weight : QP2125 QP2250 QP2375 QP2500 - 13.7 kg 15.0 kg 18.0 kg 20.2 kg QP2500 720VA (3A) 25A 0.35A 500W 44.8V 20 Ohm 18.8 kg 29 www.ampereselectronics.com PA2000 Series amperes Power Amplifiers 120W 100V 240W 100V 360W 100V 480W 100V Introduction | | | | PA2120 PA2240 PA2360 PA2480 Features PA2000 Series of amplifiers had been a reliable workhorse for years and had been refined to perform more efficiently. It is available with power ratings of 120W to 480W 100V line, in 2 HU height for space saving. Various protection features are included with the objective of providing trouble free operation for years to come. Available in various ratings ; from 120W to 480W 70 or 100V line 4 Ohm speaker connection available with 25V output Thermal protection by muting input signal (typically 85 deg at heat sink) Momentary short circuit protection Temperature dependent dual speed cooling fan Balanced input signal with gain control and selectable grounding option AC and DC operation for uninterrupted operation during power failure Packing information Qty per carton : 1 unit WxHxD : PA2120 / PA2240 / PA2360 / PA2480 : 550 x 180 x 465 mm Weight : PA2120 PA2240 PA2360 PA2480 - Application Schematic 13.4 kg 14.6 kg 17.4 kg 19.4 kg From pre-amplifier Loop to next amp in. 24V DC battery backup Output to speakers or zone selectors parallel to next amplifier Technical Specifications Power requirement Power consumption (240V ac) Current consumption (24V DC) Standby current (24V DC) Input signal Input gain controls Rated output (100V, RMS) 4 Ohm output voltage Output impedance (max load) Frequency response S/N ratio THD + N Protections Cut off temperature Cooling system Indications Dimensions (W x H x D) Net Weight 30 www.ampereselectronics.com PA2120 280VA (1.3A) 8A 0.2A 120W 22V 83 Ohm 12 kg PA2360 PA2240 230 / 240V ac or 24V DC back up supply 560VA (2.3A) 420VA (1.75A) 19A 14.5A 0.3A 0.25A 1V / 10K Ohm; balanced via XLR female -40 to 4 dBu 360W 240W 38V 31V 27 Ohm 42 Ohm 70Hz - 15 KHz @ 1KHz +/-3 dB >70 dB @ 1 KHz, 1V <0.18 % Thermal, Short circuit, Overload, Fuse 75 Deg C Auto temperature controlled fan speed LED : Power, Signal level 482 x 88 x 335 mm 16.2 kg 13.3 kg PA2480 700VA (3.0A) 24A 0.32A 480W 43.8V 20 Ohm 18.2 kg DP2000 Series Power Amplifiers Multi Channel Power Amplifiers amperes DP2406 | 4 Ch 60W 100V Multi Channel DP2212 | 2 Ch 120W 100V Multi Channel Introduction D DP2406 is a quad channel with power rating of 60W 100V line per channel whereas DP2212 is dual channel of 120W 100V line per output. With its Class D amplification, it has various advantages over conventional power amplifiers, notably its higher power efficiency, lesser heat dissipation as well as flatter frequency response. It is most suitable for Matrix setup, which multiple channels of amplifiers are required and with lesser unit count of amplifiers, it translates into more rack space savings and lower overall setup costs. High Temperature Operating Multichannel Class D Features Class D amplifiers for wider frequency response Low power loss with higher efficiency circuits Rear View DP2406 Available in 2 x 120W or 4 x 60W 100V Line High ambient temperature operating condition AC and DC operation Rear View DP2212 Application Schematic Multiple Input Sources MxP2288 Technical Specifications DP2406 DP2212 Rating 4 x 60W 100V line 2 x 120W 100V line Operating voltage 230 ~ 240V ac / 24V DC Current consumption 1.4A on 240V AC Current (Load / Standby) 10.2A/0.7A on 24V DC Input 4 x XLR 2 x XLR Input level 1.25 Vrms Balanced Outputs 100V, 70V, 30V Frequency response 100Hz ~ 16kHz + / - 3 dB Thermal, short circuit AC & DC fuse Protection Power, audio input level, over temperature, amplifier faulty Indicator Via continuous operating fan Cooling system Dimension (WxHxD) 482 x 88 x 335 mm Weight 13.3 kg 12 kg MxP 2288 DP2406 DP2212 3 4 DP 2406 PUBLIC ADDRESS POWER AMPLIFIER 1 2 x 120W POWER AMPLIFIER 2 3 4 SPEAKER 5 6 Packing information Qty per carton : 1 unit WxHxD : DP2212 / DP2406 : 550 x 180 x 465 mm Weight : DP2212 - 13.7 kg DP2406 - 15 kg 31 www.ampereselectronics.com MA2000 Series Mixer Amplifiers Power Amplifiers amperes 60W 100V Mixer Amp With 3 Zone Output | MA2060 120W 100V Mixer Amp With 3 Zone Output | MA2012 240W 100V Mixer Amp With 3 Zone Output | MA2024 Application Schematic Introduction MA2000 Series, available in power rating of 60 to 240W 100V line is suitable for small setup such as showrooms, shops, function rooms or small mosques. It has 3 selectable zone outputs with remote selection from PM Series of paging microphones with muting feature. FRONT INP MICROPHONE DYN.MIC Optional media player module for USB / SD Card MP3 playback and AM FM tuner is available for 240W version with prefix P (MA2024P). ON LINE MIC LINE MIC LINE MIC LINE MIC REMOTE MIC Line output to extend to booster amplifier SPEAKERS Features Z1 CD1001 CD 1001 Z2 I O VOL CTRL 6 mic / line selectable input channels, with front mic jack, phantom power Priority muting for mic input 1 with adjustable muting level 3 zone speaker output with ALL CALL and remote triggering port 100V line output with aux 4 Ohm speaker terminal Tone and bass controls Z3 AC / DC operation Variants : MA 20xx / P : with USB / SD card / FM tuner player MA Series is available with optional media player module Technical Specifications Ratings Operating voltage 24V DC requirement Current (Load / Standby) Input channel Input phantom power Input sensitivity / impedance Tone controls Outputs Output selection Frequency response Protections Indicators Cooling system Dimensions (WxHxD) Weight 32 www.ampereselectronics.com Packing information Qty per carton : 1 unit WxHxD : MA2060 / MA2012 : 550 x 180 x 430 mm Weight : MA2060 - 11.0 kg : MA2012 - 12.1 kg : MA2024 - 14.0 kg MA2060 60W 100V line MA2012 MA2024 240W 100V line 120W 100V line 230 ~ 240V ac / 24V DC 4A 8A 15A 1.3A / 0.4A 2.2A / 0.4A 6.1A / 0.3A 6 : 2 MIC ( XLR), 4 MIC/Line Selectable (RCA/Phone Jack) Mic 1 and 2 ; 12V DC 2 x Mic (XLR) & 4 x Mic 2 x Mic (XLR) & 4 x Mic (Phone jack) : 20 mVrms (Phone jack) : 4 mVrms 4 x LINE (RCA) : 150 mVrms 4 x LINE (RCA) : 350 mVrms Bass (100 Hz) ; Treble (10 KHz) +/- 3 dB 3 Zone 100V line, 4 Ohm Front and remote triggering 175 ~ 18 KHz 70 ~ 15 KHz Thermal, short circuit, AC and DC fuse AC mains, clip, protect, audio input level Dual speed fan with heat sensing 424 x 88 x 300 mm 9.8 kg 10.9 kg 12.8 kg 33 Basic Mixing Amplifiers amperes MC2000 Series Power Amplifiers MC2106 | 60W 100V Mixer Amp MC2112 | 120W 100V Mixer Amp IMPROVED Features Introduction MC2000 Series offer simple mixing amplification for small setups or functions such as shops, boutiques, meeting rooms or a small gathering venues. Two versions are available ; 60 and 120W 100V line outputs. Though being basic, it is equipped with various protection features such as thermal and short circuit protections. 6 inputs for mic and line with phantom power for input 1 Tone and bass controls 70 / 100V line output with 4 Ohm terminal with audio line output Short circuit, thermal protections Application Schematic Rear View: 8 OHM SPEAKERS OR 100V SPEAKER WITH MATCHING TRANS PAGING MIC I O CD1001 CD 1001 CD 1001 Packing information Qty per carton : 1 unit WxHxD : MC2106 / MC2112 : 560 x 165 x 295 mm Weight : MC2106 : 7.80 kg : MC2112 : 8.65 kg stereo DYNAMIC / COND. MICROPHONE I O Technical Specifications MC2106 Rating Operating voltage 24V DC requirement Current (Load / Standby) Input channel Input phantom power Input sensitivity @ 1W / 4 Ohm Tone controls Outputs Frequency response (± 3dB @ 1Kz 20 ~ 20 KHz ) SNR THD+N (at rated power) Protections Indicators Cooling system Dimensions (WxHxD) Weight MC2112 60W 100V line 120W 100V line 230 ~ 240V AC mains 1.2A / 0.1A 2.2A / 0.1A 6 inputs; 4 Mic phone jack, 2 line selectable (RCA) Mic 2 : 12V DC Mic : 430 mV Line : 650 mV RCA : 642 mV Bass (150 Hz) ; Treble (10 KHz) ± 3 dB 4 Ohm / 100V line 120 Hz - 15 kHz 76 dB @ 1 kHz, 1V 0.02% Thermal, short circuit, AC and DC fuse Power, Audio Input Level Fan with dual speed 424 x 88 x 180 mm 7.05 kg 7.80 kg 33 www.ampereselectronics.com Technical Info amperes SPL (dB) TO POWER AND DISTANCE The Sound Pressure Level ( SPL ) shall drop 6 dB whenever the distance from source is doubled. It can be calculated from the formula : Distance (m) 2 4 8 10 15 20 30 40 50 60 80 100 dB Loss 6 12 18 20 23.5 26.0 29.5 32 34 35.6 38 40 SPL drop = 20 log D ( D= distance in metre ) SPL ( dB ) shall increase 3 dB when the power to speaker is doubled, calculated from : Power (W) dB Increase SPL = 10 log W ( W = power input ) SPEAKER CABLING IN 100V LINE SYSTEM Cables used in PA installations are subjected to losses as similar to the cablings in electrical installations. The factors affecting the percentage loss include the cable size, length, cable materials, input voltage, load and tempera ture. A typical loss chart with relation to cable size is shown below. ( Copper conductors in single phase ). For accuracy, please refer to the manufacturer’s data sheet. 1 2 4 8 10 15 20 30 40 50 80 100 0 3 6 9 10 11.8 13 14.8 16 17 19 20 Length in Meter for 0.5 dB Power Drop (Appr 81% at Load ) Cable Gauge Conductor Size Impedance AWG ( mm sq ) Ohm / 1000ft 10 5.26 1.00 11 4.17 1.26 12 3.31 1.59 13 2.62 2.00 14 2.08 2.53 15 1.65 3.18 16 1.31 4.02 17 1.04 5.06 18 0.82 6.39 125W power 250W 500W Load 20 Ohm 190 150 120 90 75 60 45 35 26 500W 1 dB loss 3 dB loss 1 dB loss 3 dB loss 1 dB loss 3 dB loss 12 1727 1087 6045 3805 862 542 3017 1897 429 270 1502 945 14 683 2391 341 1194 170 595 16 430 1505 215 753 107 375 18 269 942 134 469 67 235 10 Total Impedance 800 Ohm 400 Ohm 300W Load 33 Ohm 320 260 200 160 130 100 70 60 50 200W Load 50 Ohm 490 390 310 240 190 150 110 90 70 100W Load 100 Ohm 990 780 620 490 390 310 240 170 150 50W Load 200 Ohm 1990 1580 1250 990 780 620 480 390 310 The table provides an approximate cable length permissible for specified loss of signal in 100V line speaker installation. 200 Ohm FIBER OPTIC CABLES IN PA INSTALLATIONS Laying of copper cables may not be wise in installations such as railway stations communications, sparsely located buildings or remotely located paging points. They may pose hazards like lightning strike, inteferences as well as signal drop, and thus affect the performance and lifespan of the installation. Fiber optic cabling is an alternative solution and applying IP to the system would make the PA setup to be cost effective, safer, expandable and more efficient. Followings are the items required for fiber optic installation : IP PA Server / Controller - Amperes iPX5101 ( one per system ) IP PA Client / Adaptor - Amperes iPX5151 ( one for each location ) Network Switch, 10/100T or higher Cat 5e to Fiber Converter ( if Fiber optic network switch unavailable ) Fiber optic cable ( Single / Multimode ) - 2 core For short distance ( typically around 2 km ) multimode cable shall be used and single mode type for longer distance. 34 www.ampereselectronics.com 6 Duty / 1 Standby Changeover Panel amperes AX700 / AC3601 Changeover & Monitoring AX700 | 6 Duty / 1 Standby Amplifier Changeover Panel AC3601 | 6 Duty / 1 Standby Manual Changeover Panel Introduction Features AX700 is a platform for standby amplifier to take over failed duty unit in an automated changeover setup. Each unit caters for 6 duty and 1 standby amplifier but expandable to larger setup with a single standby power pack. It shall be used with amplifier with auto fault sensing (AFS) such as QP series and whereas normal amplifiers are used, Amperes AS4000 shall be installed at every duty unit. AX700 has protection feature that only allows a single takeover to prevent overloading. Cater for 6 duty and 1 standby amplifier Expandable for 1 standby to serve more than 6 duty units Overload protection by allowing only a single take over Prioritized changeover - unit with higher number is preferred for changeover Fault alert with LED indicator and switchable buzzer Compatible with most auto detection cards AX700s 6 Duty / Standby Amplifier Changeover Panel AC3601 6 Duty / 1 Standby Manual Changeover Panel Amperes AC3601 is a manual changeover panel for 6 duty with 1 standby amplifier and is required for a standby unit to take over a failed duty amp to ensure uninterrupted and continuous operation of a PA system. More than one AC3601 can be cascaded for a single standby unit to cater for more than 6 duty packs. Protection circuitry is embedded that only allows one failed duty amplifier to be taken over by standby unit to prevent overloading. Priority features shall ensure higher numbered failed unit has preference for changeover. Features Cater for 6 duty and 1 standby amplifier Expandable for 1 standby to serve more than 6 duty units Overload protection by allowing only a single take over Prioritized changeover - unit with higher number is preferred for changeover Manual front panel changeover selection IN P L E AS E O B S E R V E P O L A R IT Y OUT HOT HOT S TA N D B Y A M P INP U T COM COM COM HOT HOT HOT COM COM HOT COM HOT HOT COM HOT COM COM COM DU TY A M P L IF IE R INP U TS HOT 6 HOT 5 HOT 4 COM 3 COM 2 COM 1 S/BY + COM A M P .F A U LT DE TE C T TR IG G E R D C 24V 0 .5 A HOT AUTO AM P. C HAN G E OVE R Rear View AX700 : A M P.IN A M P .O U T S /B Y IN D U TY A M P S/B Y A M P IN OU T L IN K TO A S4 0 0 TO ZON E SELEC TO R OR SPEA KERS AX 7 0 0 W IR IN G C O N N E C T IO N S AM P . IN - FR . AM P O U T P U T S AM P . O U T - T O Z O N E S E L E C T O R / S P E A K E R S M AX L O AD / C H - 4 0 0 W / 1 0 0 V L IN E LIN K COM TO A S4 0 0 1 ~ 6 DE TE C T Q u a lit y P ro d u c t Fro m A M P E R E S E LE C T R O NI C S A X7 0 0 Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.5 kg Rear View AC3601 : IN OUT HOT S TAN D B Y C AS C AD E LIN K AM P I N PU T COM HOT COM COM HOT HOT COM COM HOT COM HOT COM HOT HOT HOT COM COM COM HOT HOT HOT COM COM HOT COM AC 3601 D U TY AM PLIFIER IN PU TS DC 24V USAGE OF NON RECOMMENDED POWER SUPPLY UNIT MAY CAUSE DAMAGE TO THIS EQUIPMENT DC SUPPLY RATING : 24V DC, 0.5A + ( PS9400 RECOMMENDED ) WIRING CONNECTIONS LINK IN - FR. N-1 AC3601 LINK OUT - TO NEXT AC3601 MAX LOAD / CH - 400W / 100V LINE PLEASE OBSERVE POLARITY IN L IN K O UT D UT Y A M P S/ B Y A M P AMP.IN AMP.OUT S/BY IN TO ZONE SELECTOR OR SPEAKERS AC3601 another quality product from a m p e re s e le ct r o n ics Technical Specifications AX700 Operating voltage Power consumption Zone load rating Amplifier inputs Indications Switching mode Changeover alert Changeover section Cable connection Cable size Dimensions (WxHxD) Weight AC3601 24V DC via PS9400 PSU Standby : 82 mW, 3.4A Operating : 1.3W, 50 mA 500W / 100V line per ch. 6 Duty / 1 Standby Front switch LED Red LED for take over Green - normal / non c/over Dry contact activation by AS4000 Via front panel switch Buzzer, LED Amplifier outputs only Plug in connectors 2.5 mm sq 482 x 44 x 180 mm 2.0 kg 35 www.ampereselectronics.com AX3800 Changeover & Monitoring 8 Duty 1 Standby Auto Amp. Changeover Panel amperes IMPROVED Introduction AX3800 offers great flexibility and simplicity for amplifier fault changeover setup. With the precise circuit design, amplifier fault detection period is greatly reduced to initiate timely changeover to standby unit. The internal pilot tone generation at 20KHz is set at optimum interval to avoid unnecessary loading to amplifiers. Changeover shall occur at both input and output of amplifiers, making it suitable for application in a matrix system. Priority and single changeover ensures overloading of standby amplifier is avoided, thus providing a reliable and uninterrupted system at most times. 20KHz Simplified Cabling Pilot Tone Generator Shorter Fault Detection Features Cater for 8 duty and 1 standby Expandable for 1 standby to cater for more than 8 duty amps. Built in Pilot Tone generator, transmit at intervals and senses at sequence to protect amplifiers Rear View: Overloading protection by allowing only a single take over Prioritised changeover which higher numbered amplifier shall be preferred for take over if more than two units are down AUDIO SIGNAL INPUTS / OUTPUTS - + - G + - CHANNEL 2 SIGNAL LINK INPUT OUTPUT LINK OPEN + - G + - STANDBY FAULT CONT. OUTPUT 3A NO MAX - G + CHANNEL 1 SIGNAL LINK INPUT OUTPUT LINK OPEN OUTPUT + LINK OPEN - INPUT G + - STANDBY AMP Shorter fault detection time from 7 to 15 seconds CASCADE RS 485 CHAN. 1 ON CHAN. 2 ON CHAN. 3 ON CHAN. 4 ON CHAN. 5 ON CHAN. 6 ON CHAN. 7 ON HIGH IN- IN+ + CHANNEL 3 SIGNAL LINK INPUT G CHAN. 8 ON LOW CHANNEL 1 - IN+ CHANNEL 2 OUT+ CHANNEL 4 OUTPUT LINK OPEN + IN- - OUT+ + OUT- G OUT- IN- IN+ - IN- CHANNEL 3 OUT+ IN- + SIGNAL LINK INPUT OUTPUT LINK OPEN IN+ - CHANNEL 4 IN+ IN- IN+ OUT+ CHANNEL 5 + CHANNEL 5 SIGNAL LINK INPUT G OUT+ - OUT- + OUT- CHANNEL 6 OUTPUT LINK OPEN OUT- - CHANNEL 6 IN + CHANNEL 7 + IN - G OUT - IN+ IN- OUT- OUT+ CHANNEL 8 DC 24V 0.5 A + - - SIGNAL LINK INPUT OUTPUT LINK OPEN + OUT + - IN+ + CHANNEL 7 SIGNAL LINK INPUT G IN- - OUT+ + OUT- CHANNEL 8 OUTPUT A B ON SWITCH TO OFF FOR UNUSED CHANNEL CHANNEL / AMP. DETECTION SWITCHES Changeover at input and output section simultaneously ; suitable for matrix system installations Input link switch ; making connection of sources easier Channel isolation switch for unused or un-monitored channel Application Schematic DUTY AMP PA 2120 DUTY AMP PA 2120 PA 2120 I O Technical Specifications POWER I O I O POWER POWER STANDBY AMP Individual channel status indicators ; normal, fault and changeover SIGNAL -40 dB SIGNAL -10 dB CLIP PROTECT POWER SIGNAL -10 dB CLIP SIGNAL -40 dB PROTECT POWER CLIP SIGNAL -40 dB SIGNAL -10 dB PROTECT POWER 100V 120 Watts PA 2120 120 Watts PA 2120 120 Watts PA 2120 audio + PT INPUT SOURCES OFF CH1 CH2 CH3 CH4 CH5 CH6 SOURCE TUNER MAX MIN SIG IN MAX MIN MAX SIG IN MIN MAX SIG IN MIN MAX SIG IN MIN SIG IN MAX MIN MAX MAX CHIME MIN AX 3800 TREBLE POWER AMP. FAULT 1 2 3 4 5 6 7 8 PILOT TONE STANDBY AMP. FAULT amperes 24V DC overriding 1 amperes 2 3 4 5 6 7 SPEAKER ZONE SELECT 8 9 10 11 12 ALL CALL 24V DC overriding SPEAKERS www.ampereselectronics.com ZONE SELECTOR VOL CTRL Cascade AX3800 if more than 8 duty amps are installed 36 O AUX MAX MUSIC SOURCE FIRE AX3800 6 1 MIN SIG IN E/M PANEL ZS 5121 OVERRIDE BASS MIC SIREN ACTIVATE AMP. NORMAL AMP. NUMBER AMP. CHANGEOVER 100V 1 6 100V I CASS CD MAX MIXER SIG IN TEST AM 6000 POWER TONE CTRL OFF MIN MIN SIG IN audio SELECT MASTER EXT INPUT MX 2122 Operating voltage Power consumption Input signal Input impedance Audio output gain Pilot tone interval Pilot tone frequency Detection line Detection level Failure detection time Failure recovery time Zone load rating Status indication LED Changeover alert Changeover section Dimensions ( WxHXD ) Weight 24V DC ; 1A 6.8 W 8 Ch balanced line signal 10 K Ohm Unity 8 seconds / channel 20 KHz ( +/- 5% ) 70 / 100 V line 50 V rms min 7 - 15 seconds 20 seconds max 500W / 100V line max Normal ; Fault ; Changeover Buzzer with switch Input and output simultaneously 482 x 88 x 180 mm 2.85 kg Packing information Qty per carton : 1 unit WxHxD : 560 x 165 x 295 mm Weight : 3.6 kg amperes 6 Ch Speaker Line Surveillance Introduction Features Changeover & Monitoring 6 channel speaker line monitoring and expandable LS4600 provides reliable speaker circuit monitoring for ground leakage, short and open circuit at user settable intervals. Impedance measurement method is used in determining the health of the circuit, thus giving flexibility over cabling routings. Basic and Advance level of detection setup Detection of faulty cable and speaker in individual zone or circuit It is loaded with features that would enable the device to be fitted to any PA installations with different requirements of setups. Impedance measurement method - no capacitor coupling required and cable branching allowed. Faulty circuit disconnection option Technical Specifications Operating voltage Power consumption Capacity Processor Impedance detection range Power measurement range Measurement accuracy Pilot tone injection frequency Pilot tone signal output level Transmittal detection period Detection interval Sensitivity setting Indicators - LED Display LCD Audible output signal Dry contact setting DC output in detection mode Dimensions (WxHxD) Weight LS4600 Built in impedance meter, range within 10 Ohm to 10 K Ohm LCD display to facilitate system setup, measurement and monitoring 24V DC via PS9400 PSU 3.5W 6 channel and expandable PIC micro controller with 12 bit ADC 10 to 10 K Ohm 3 to 1000W 100V line +/- 3% within range 1 KHz 5V sine 3 seconds per channel User preset from 1 min to 48 hrs User preset at each channel Normal, Fault, Buzzer, Auto run 2 x 16 characters w back light Continuous buzzer with Off option 3A 24V DC for individual channel 482 x 44 x 180 mm 2.3 kg Fault alert with LED indicators and switchable buzzer Detection test interval setting from 1 min to 48 hours Short burst test signal, minimizing interruption to PA operation User setting for detection sensitivity for open, short and leakage Aux 24V DC output for volume controller overriding during testing mode Rear View: Application Schematic multiply LS4600 as required ZONE SELECTOR LS4600 SPEAKER 100V 10 3 4 3 2 1 PATCH PANEL VOL CTRL 5 6 7 SPEAKER ZONE SELECT 5 6 8 9 1 2 UP DOWN M ENU 4 5 6 11 12 1 2 3 4 5 6 ALL CALL a m pe r e s QP2000 POWER AMPLIFIER VR7000 4 SPEAKER PATCH PANEL SPEAKER VOLUME 2 1 OFF 3 4 5 3 I O OVERRIDE OVERRIDE 1 5 0 0 W 1 0 0 V L IN E P O W E R A M P LIFIE R POW ER 2 E/M OVERRIDE VR 7000 2 ZS 5121 Q P 2 5 00 SPEAKER VOLUME 1 OFF 3 4 5 OVERRIDE Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.9 kg 24V emergency override signal 37 www.ampereselectronics.com AM4120 Changeover & Monitoring Amplifier Monitor Panel Introduction AM4120 shall be used to monitor amplifier outputs of 70 / 100V line at the rack which is equipped with level meter, amplifier output LED and speaker for audio monitoring. It can also be used as a tool to calibrate sound output level of each amplifier from the rack. Rear View: amperes Features 12 inputs for 70 / 100V line amplifier outputs Dual mode monitoring with continuous signal indicator Audio monitoring with volume control Technical Specifications Operating voltage Power consumption Amplifier inputs Monitoring mode Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 2.8 kg Dimensions (WxHxD) Weight 24V DC via PS9400 PSU 50 mW 12 : 70 / 100V line Audio : 1W speaker with 5 presets Visual : segment LED level meter LED for all channels 482 x 44 x 180 mm 2.1 kg AS4000 | Amplifier Surveillance Module Technical Specifications AS4000 is used to monitor the status of 70 / 100V line power amplifiers which do not have built in detection module. Every amplifier shall employ one AS4000 and the dry contact output from the unit shall then be connected to Amperes AX700. Repeating this link shall then form an automatic amplifier fault changeover / surveillance system. Features Interval Pilot Tone injection ; reduces strain to amplifiers Works independently with or without availability of audio signal Low distortion to original audio signal Status monitoring via LED ; Pilot Tone and amplifier fault Compatible with most 70 / 100V line amplifiers in the market 38 www.ampereselectronics.com Operating voltage Power consumption Input impedance Output impedance Max audio input Max audio output Transmit interval Detection delay Recovery time Frequency response Detection output Dimensions (WxHxD) Weight 24V DC via PS9400 PSU 200 mW nominal 10 K balanced 600 Ohm balanced 0.75V 1.2V 10 seconds 20 seconds 30 seconds 20 - 20 KHz NO and NC dry contact 120 x 96 x 28 mm 330 gms ZS5062 / ZS5122 Selector & Data Decoder amperes ZS5062 | 6 Ch Speaker Zone Selector ZS5122 | 12 Ch Speaker Zone Selector RS485 Fail Safe Remote Monitor Features Introduction Available in 6 and 12 zones ; expandable to 192 zones These next generation of zone selectors are introduced to meet the new demands for a fail safe equipment. They are available in 6 and 12 zones and expandable to larger configurations. Fail safe zone trigger during power or unit failure Remote zone triggering via analogue and RS485 data ZS5602 / 5122 may look and function similarly with other zone selectors but they have several distinctive features for safety, operation and monitoring. All zone contacts shall automatically closed during power failure or damage to the unit, which is vital to continuous emergency broadcast. RS485 communication port is available for remote triggering or monitoring via PMX software. Zone monitoring via PMX II software Local paging overriding bypassing BGM Flexible amplifier to zone configuration ZS5062 6 Ch Speaker Zone Selector ZS5122 12 Ch Speaker Zone Selector Technical Specifications Dimensions (W x H x D) Weight 2 4 8 ON Quality Product From AMP 6 ZON6 100V 100V 100V 100V 100V 100V 100V 100V COM ZON5 COM AMP 5 COM ZON4 COM AMP 4 COM ZON3 COM AMP 3 COM ZON2 COM AMP 2 COM ZON1 COM AMP 1 COM REMOTE SELECT ZONE 1 TO 6 1-Z1 2-Z2 3-Z3 4-Z4 5-Z5 6-Z6 7-24V 8-COM 100V UNIT ADD 1 100V RELAY RELAY Z RS485 TRIG CONT PR A B 100V - 100V + COM ZONE SELECTOR ZS 5062 AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6 AMPERES ELECTRONICS Quality Product From AMPERES ELECTRONICS 2 4 ON 8 100V 100V 100V 100V 100V 100V 100V Packing information Carton : Weight : : Qty : COM ZON12 COM AMP12 COM ZON11 COM AMP11 COM ZON10 COM AMP10 COM ZON9 COM 100V AMP 9 100V 100V ZON8 COM 100V 100V AMP 8 100V 100V ZON7 COM 100V AMP 7 COM 100V 100V AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6 REMOTE SELECT ZONE 7 TO 12 1-Z7 2-Z8 3-Z9 4-Z10 5-Z11 6-Z12 7-24V 8-COM 100V ZON6 COM AMP 6 100V ZON5 100V AMP 5 COM ZON4 COM AMP 4 COM ZON3 COM AMP 3 COM ZON2 COM AMP 2 COM ZON1 COM AMP 1 COM REMOTE SELECT ZONE 1 TO 6 1-Z1 2-Z2 3-Z3 4-Z4 5-Z5 6-Z6 7-24V 8-COM 100V UNIT ADD 1 COM RELAY RELAY Z RS485 TRIG CONT PR A B COM - 100V + 100V DC 24V 100V Rear View ZS5122: COM ZS5122 24V DC via PS9400 adaptor 6.25W 3.29W 0.72W 0.96W 0.14A 0.26A 0.03A 0.04A 500W at 100V line 6 12 6 12 Front panel switch and remote 16 -ve triggered (common ground) Individual zone switch, Priority RS485 19.2 kbps baud rate Individual, All Call Local zone selection bypassed when remote trigger is activated 482 x 44 x 180 mm 1.85 kg 2 kg DC 24V ZONE SELECTOR ZS5062 ZS 5122 Operating voltage Power consumption (idle) Power consumption (All Call) Current consumption (idle) Current consumption (All Call) Max load / channel Number of zones Amplifier inputs Zone selection Cascade limitation Remote triggering Indicators Data communication Switching mode Rear View ZS5062: AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 7 TO 12 560 (W) x 95 (H) x 295 (D) mm ZS5602 : 2.5 kg ZS5122 : 2.7 kg 1 unit / carton 39 www.ampereselectronics.com ZS5601 / ZS5121 6 / 12 Ch. Speaker Zone Selector Selectors & Data Decoder amperes 6 Ch Speaker Zone Selector | ZS5601 12 Ch Speaker Zone Selector | ZS5121 Introduction Features ZS5601 and 5121 are trusted product for speaker zone selection which had been used for more than a decade. Available in 6 (ZS5601) and 12 zone (ZS5121) respectively with ALL CALL They provide direct zone switching for single source PA setup via front panel switches or through remote port connected to Amperes PM Series paging desk, or through Amperes TD decoders when PD series of paging desks are used. Other made of paging consoles are compatible with ZS provided they have negative triggering switching ports. Remote zone triggering port via external paging microphone or console A distinctive feature shall be the remote override function which bypasses local zone selection whenever a paging mic connected to it is activated. The individual input and output connections make it flexible for amp-zone configurations as well as for matrix setup. Expandable to more zones as required Paging override by Amperes paging console with Priority override indicator Emergency paging mic triggering port with dry contact for volume controller overriding application Flexible amplifier to zone configuration ZS5601 6 Ch Speaker Zone Selector ZS5121 12 Ch Speaker Zone Selector DC 24V + RLY TRIG PLEASE OBSERVE LINE POLARITY WHEN CONNECTING CABLES AMP.6 REM. PAGING MIC E/M TRIG REL.CONT DC24V ZONE 1 ZONE 6 SPEAKERS AMP.1 AMP INPUTS TYPICAL CONFIGURATION DO NOT OVERLOAD ZONE MAX LOAD/ZONE : 400W CONNECT REMOTE / RELAY PORT ONLY IF APPLICABLE AMP.IN LOOPING ALLOWED REMOTE SELECT ZON6 COM COM AMP 6 100V COM ZON5 COM COM AMP 5 100V COM ZON4 100V AMP 4 100V COM COM ZON3 100V AMP 3 100V COM ZON2 COM AMP 2 100V AMPLIFIER INPUTS - ZONE OUTPUTS FOR ZONE 1 TO 6 100V ZON1 100V AMP 1 COM 1-Z 1 2-Z 2 3-Z 3 4-Z 4 5-Z 5 6-Z 6 7 --V E 8 -+ V E COM P IN P IN P IN P IN P IN P IN P IN P IN 100V REMOTE SELECT 100V RLY RLY ZS TRIG CON PR 100V DC 24V + ZONE OUTPUTS Rear View: Quality Product From AMPERES ELECTRONICS RLY ZS CON PR P IN 1 -Z 1 P IN 2 -Z 2 P IN 3 -Z 3 P IN 4 -Z 4 P IN 5 -Z 5 P IN 6 -Z 6 P IN 7 -AC P IN 8 -PR P IN 1 -Z 7 P IN 2 -Z 8 P IN 3 -Z 9 P IN 4 -Z 10 P IN 5 -Z 11 P IN 6 -Z 12 P IN 7 -AC P IN 8 -GND Application Schematic 24V DC REG. POWER TEST AM 6000 S IR E N A C T IV A T E POW ER FIR E POWER PA 2480 PROTECT amperes CLIP SIGNAL -10 dB SIGNAL -40 dB PUBLIC ADDRESS POWER AMPLIFIER DC 24V + RLY RLY ZS TRIG CON PR P IN 1 -Z 1 P IN 2 -Z 2 P IN 3 -Z 3 P IN 4 -Z 4 P IN 5 -Z 5 P IN 6 -Z 6 P IN 7 -AC P IN 8 -PR P IN 1 -Z 7 P IN 2 -Z 8 P IN 3 -Z 9 P IN 4 -Z 10 P IN 5 -Z 11 P IN 6 -Z 12 P IN 7 -AC P IN 8 -GND M IC a mp e r e s for E/M override Dry contact for link to other application / EM overriding TO SPEAKERS (VARIOUS ZONES) N+3 Multicore Cable N= No of Zones remote zone trigger AMPERES PM1060 / 1120 REMOTE PAGING MICROPHONES (OR OTHER BRANDS WITH NEGATIVE TRIGGER) 40 www.ampereselectronics.com 560 (W) x 95 (H) x 295 (D) mm ZS5601 : 2.3 kg ZS5121 : 2.8 kg 1 unit / carton Technical Specifications POWER AMPLIFIERS (70/100V) E/M PANEL TRIGGER OR OTHER TRIGGERING METHOD Packing information Carton : Weight : : Qty : ZS5601 OR ZS5121 Operating voltage Power consumption Max load / channel Number of zones Amplifier inputs Zone selection Cascade limitation Remote triggering Indicators Switching mode Dimensions (W x H x D) Weight ZS5601 ZS5121 24V DC adaptor 3.5W, 0.14A w All Call 6.8W, 0.28A w All Call 500W at 100V line 6 12 6 12 Front panel switch and remote Unlimited -ve triggered (common ground) Individual zone switch, Priority Individual, All Call Local zone selection bypassed when remote trigger is activated 482 x 44 x 180 mm 1.7 kg 2.1 kg ZS5602 / SS6401 Selector & Data Decoder amperes ZS5602 Introduction Features ZS5602 shall be suitable for uninterrupted paging setup, ie. when an announcement to a zone is made, other areas with BGM shall not be interrupted. Available in 6 zones for BGM and 6 for Paging with ALL CALL This shall require two sets of amplifiers connected to the ZS5602, thus the system shall consist of two sources, one being BGM and the other as Paging. Remote zone triggering port via external paging mic Similarly to ZS5601 / 5121, paging zone can be remotely triggered and each zone shall have separate amp input - zone output terminals, thus making it flexible for amp-zone configuration. Aux DC output for selected paging zone Rear View ZS5602: PLEASE OBSERVE POLARITY WHEN CABLING ZON6 COM AMP6 COM ZON5 COM COM AMP5 100V COM ZON4 100V COM AMP4 100V COM ZON3 100V COM AMP 3 100V COM ZON2 100V AMP 2 100V BGM AMPLIFIER INPUTS - NORMAL BGM OUTPUTS COM ZON1 100V AMP 1 COM 6 100V 24 V 4 5 COM 3 100V 2 100V ZONE DC OUTPUTS 1 100V COM COM COM ZON6 100V COM ( OR 3 WIRE SYSTEM PRIORITY ZONE OUTPUTS ) AMP 6 100V COM ZON5 100V COM AMP 5 100V COM ZON4 100V AMP 4 100V COM ZON3 100V COM AMP 3 COM ZON2 100V COM PAGING AMPLIFIER INPUTS - ZONE OUTPUTS 100V COM AMP 2 100V ZON1 100V 100V AMP 1 Expandable or link multiple units to form more zones Emergency paging mic triggering port with dry contact for volume controller overriding application Suitable for 3 or 4 wire system Application Schematic ( 3 WIRE SYSTEM ONLY ) REMOTE PAGING MICROPHONE Technical Specifications BGM SOURCES MIXER MX2222 OFF CH1 CH2 CH3 CH4 CH5 CH6 SOURCE Operating voltage Power consumption Insertion loss Max load / channel Number of zones Amplifier inputs Zone selection - BGM Zone selection - Paging Indicators Aux output voltage Dimensions (WxHxD) Weight 24V DC ; 0.5A 10W ; 0.42A at ALL CALL 0.5 dB max 500W at 100V line 6 6 BGM ; 6 Paging Front panel switch Front panel switch, remote Zone LED 24V DC ; 3A max / zone 482 x 44 x 180 mm 2.2 kg SELECT TONE CTRL TUNER OFF MIN MAX CHIME MIN MAX SIG IN MIN SIG IN MAX MIN MAX SIG IN MIN SIG IN MAX MIN MAX SIG IN MIN SIG IN MAX MIN POWER MASTER EXT INPUT MX 2122 MIN TREBLE I CASS CD MAX MIXER MAX SIG IN AUX O BASS MIN MAX SIG IN MUSIC SOURCE BGM Paging PAGING AMPLIFIERS BGM AMPLIFIERS PA 2060 PA 2060 60 Watts 60 Watts POWER POWER POWER AM 6000 I PROTECT O SIGNAL -10 dB POWER AM 6000 CLIP SIGNAL -40 dB I PROTECT O SIGNAL -10 dB CLIP SIGNAL -40 dB BGM output Paging output zone control 24V DC ZS5602 multiply ZS5602 for more zones Z1 24V DC override 100V SPEAKERS VOL CTRL Z6 SS6401 | 4 Input BGM Source Selector SS6401 has 4 BGM source input via RCA jack with mono output suitable for PA system. Its has line balancing circuitry which provide equal output level no matter which input is selected, as different BGM source has different output level. This avoids the trouble to adjust mixer volume whenever a different source is changed. Technical Specifications Input connection Output Gain (max) Selection Dimensions (WxHxD) Weight 4 input sources ; Cassette, CD, Tuner and Aux Input level balancing circuit for constant output level for different type of BGM source Rear View SS6401: SS 6401 24V DC ; 0.3A 0.15A : 2V / 47 K Ohm CD : 600 mV / 10 K Ohm Tuner Cassette : 500 mV / 10 K Ohm : 1.25V / 20 K Ohm Aux RCA mono RCA mono, 1V 600 Ohm CD : -6 dB / Tuner : 4 dB Cassette : 6 dB / Aux : -2 dB Daisy chain 482 x 44 x 180 mm 1.8 kg MUSIC SOURCE SELECTOR Input voltage Consumption Input level / Imp (max input) Features CASS DC 24V DC SUPPLY RATING : 24V DC, 150 mA OUTPUT ( UNBALANCE ) 1 V MAX AUX TUNER CD INPUT SENSITIVITY / IMPEDANCE TUNER CD CASS AUX : 200mV / 47K : 500mV / 47K : 200mV / 47K : 200mV / 47K + - Packing information Carton : Weight : : Qty : 560 (W) x 95 (H) x 295 (D) mm ZS5602 : 2.5 kg SS6401 : 2.9 kg 1 unit / carton 41 www.ampereselectronics.com TD6080 Selectors & Data Decoder 8 Ch Decoder / Zone Selector amperes Introduction Features Integrated paging mic zone decoder and zone selector for simplified system interconnections Multipoint paging input from PD series of paging mics 8 input / 8 output configurable amp – speaker line connections TD6080 is engineered for convenience, combining data decoder and zone selector in a box, which is translated into fewer component counts and cabling cost. It is also suitable for decentralised installations of multiple locations, which can communicate with central paging system through RS485 or LAN. Cascade feature for larger number of zones Configurable as group BGM / Paging for matrix setup Technical Specifications Operating voltage Consumption Max load / channels Cascade Quantity Input circuits Number of zones Amplifier inputs Zone selection Indicators Switch mode Rear View: TIME OUT 5 MIN LINE / MIC OUTPUT MASTER / SLAVE 0 DC 24V L S 5 M M + Packing information Carton : 560 (W) x 95 (H) x 295 (D) mm Weight : 2.5 kg Qty : 1 unit / carton Application Schematic PD2400 / 2800 PAGING MIC 2 PD2400 / 2800 PAGING MIC 1 PD2400 / 2800 PAGING MIC 3 Cat 5e EX1103A audio & data 2pr screen TD6080 DECODER Zone Output MX2222 PREAMPLIFIER MIXER audio output (mic / line level) OFF CH1 CH2 CH3 CH4 CH5 CH6 SOURCE SELECT TUNER MAX CHIME MAX MIN SIG IN MAX MIN MAX SIG IN MIN MAX MIN SIG IN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN Amp (100V Line) - - - - - - - - - - - - - O/P TONE CTRL OFF MIN MIN SIG IN POWER MASTER EXT INPUT MX 2122 I CASS CD a m pe re s O AUX MAX MIXER TREBLE BASS MIN MAX SIG IN MUSIC SOURCE audio output POWER MENU QP2500 I a m pe re s O UP DOWN 500W 100V LINE POWER AMPLIFIER QP2000s POWER AMPLIFIER Zone 1 SPEAKERS Zone 8 The illustration shows a setup using multiple paging mic with TD6080 as zone decoder and zone selector 42 www.ampereselectronics.com 24V DC 6W (250 mA) 500W at 100V line 31 Unit (248 zone) 2 8 8 Front panel switch & remote Individual zone switch Individual, All Call Local zone selection bypassed when remote trigger is actived AUDIO Input impedance (Ohm) Output impedance Freq response Audio input Max audio output Line : 10 K 600 Ohm balanced 70 ~ 15 KHz Line Line 1.2V DATA Data protocol Baud rate Dimension (WxHx D) Weight RS485 19.2 K bps 482 x 44 x 180 mm 2 kg 24 Ch Data Decoder amperes TD6240 Selector & Data Decoder Technical Specifications Introduction TD6240 is an intermediary equipment between PD series of paging microphone and zone selectors. It accepts up to 3 mic input circuits ; enabling multipoint paging setup and has 24 analogue switching circuits to be connected to ZS series of zone selectors. More than one TD6240 can be stacked to achieve expanded zone quantity. Features Expandable and addressable to cater for more than 24 zones Priority setting for multi point paging setup Selectable balanced audio output level (mic or line) Compatible with most zone selectors with remote triggering port Connects directly to ZS5601 / 5121 via remote triggering port using RJ45 connector Rear View: Operating voltage Consumption Switching channels Cascade / max zones 24V DC 2.4W (100 mA) 24 8 (max 192 zones) Input circuit Output connection (Triggering) 3 RJ45 to ZS zone selector AUDIO Input impedance (Ohm) Output impedance Freq response Audio input Max audio output Line : 10 K 600 Ohm balanced 70 ~ 15 KHz Line Line 1.2V DATA Data protocol Baud rate Dimension (WxHx D) Weight RS485 19.2 K bps 482 x 44 x 180 mm 2.5 kg Application Schematic PD2400 / 2800 Paging Mic 2 PD2400 / 2800 Paging Mic 1 PD2400 / 2800 Paging Mic 3 Cat 5e EX2800 EX2800 EX2800 Note : Priority level not important when connect to the Mic Connection Port of T6240 2pr screen TD6240 DECODER Cat5/ multicore cable for zone triggering audio output (mic / line level) MX2222 PREAMPLIFIER MIXER OFF CH1 CH2 CH3 CH4 CH5 CH6 SOURCE SELECT TONE CTRL TUNER OFF MIN MAX CHIME MIN MAX MIN SIG IN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN SIG IN MAX MIN POWER MASTER EXT INPUT MX 2122 MIN I CASS CD MAX MIXER a m pe re s AUX ZS 5121 a m pe re s O OVERRIDE TREBLE BASS MAX MIN SIG IN SIG IN MAX 1 2 3 4 5 6 7 SPEAKER ZONE SELECT 8 9 10 11 12 ALL CALL MUSIC SOURCE ZS5121 ZONE SELECTOR POWER MENU QP2500 I a m pe re s O UP DOWN 500W 100V LINE POWER AMPLIFIER POWER AMPLIFIER Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 3.2 kg SPEAKERS 43 www.ampereselectronics.com BC9740 24 DC Automatic Battery Charger Power Distribution amperes Features Constant DC voltage charging for 24V battery bank 4A initial charging current with reducing rate over charging time RS485 Remote Battery Protection Built in surge protection and resetable fuse Output short circuit protection Introduction Thermal protection against overheating Meet the all new next generation of innovative Battery Charger, which has been engineered to meet the requirement of installers and users alike. It is compact in 1 HU height, built with the latest technology for efficient charging, controls and monitoring purpose. Auto low battery disconnection with LCD indication Driven by powerful ARM processor, it works to protect against misconnections, prolonging battery life with its battery monitoring feature and communicates to provide human interaction. RS485 data port is available for external monitoring via PMX II Software and can be readily linked up to LAN through iPX5500 Com Box. Battery reversed polarity protection Rear mains switch to avoid unnecessary switching off the unit RS485 communication for remote monitoring via PMX II software Rear View: Input voltage Charging voltage Charging current Idle power consumption Protections Indications Displays Communication E/M back up Amp rating Terminals Dimensions (WxHxD) Weight 230 / 240V ac 28.8V dc 4A; (max 5A) 1.3W 25A resettable fuse at battery back up output Low battery auto disconnection, reverse polarity, standby protection AC mains, short circuit and low battery Charging current Charging voltage Battery voltage Output current Battery reverse polarity RS485 out; link to Amperes PMX II LAN via iPX5500 comm. box for remote monitoring 25A max ( Use external contactor / relay if required ) Battery input , EM load 482 x 44 x 180 mm 2.62 kg LOAD PROTECTION - + BATTERY INPUTS REVERSED POLARITY WARNING Amperes invites you to experience this innovative product which we had meticulously developed for the convenience of the valued users. Technical Specifications - + RS485 +A -B Quality Product From AMPERES ELECTRONICS PRESS TO RESET WARNING ! RISK OF ELECTRICAL SHOCK DO NOT OPEN THIS UNIT MUST BE EARTHED BATT IN BACK UP DC OUT BC 9740 AUTOMATIC BATTERY CHARGER DC 30A Application Schematic BC9740 PREV ENTER MENU NEXT POWER BC 9740 amperes CHARGING FAULT AUTOMATIC BATTERY CHARGER BATT IN TERMINALS Refer Note 1 BACK UP DC OUT + + - 24V DC BATT. BANK + 12V - BACK UP DC OUT TERMINALS Cable Type: Refer Note 2 + 12V Amperes PS9400 24V power supply I PS 9400 amperes O bypass for heavy load OPTIONAL HIGH AMP. RATING CONTRACTOR Refer Note 2 TO EQUIPMENTS DC SUPPLY CONTACTOR (24V DC COIL) TO HEAVY LOAD (POWER AMPS) Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 3.2 kg 44 www.ampereselectronics.com SQ9715 / PS9400 Sequential Power Switcher amperes Power Distribution SQ9715 Features Introduction 7 channel with 6A per channel; total load of 15A with surge protection Cascade 2 units to form 14 channel setup ON / OFF sequential switching Remote switching port via external noiseless contact AC output via IEC connectors with channel isolation via DIP switch Ch. 7 with delay Off option for 2 min ; suitable for video projector connection SQ9715 is suitable for applications in PA, sound and AV system in which it manages the powering sequence of every equipment in orderly manner. It works to provide a some degree of protection to the lifespan of the equipment as random powering may cause irreversible damage. It has internal surge protection to kill harmful incoming power spikes. An important tool that works to safely powering up your equipment with a touch of a button. Rear View: Lock mode to avoid incidental switching Technical Specifications Operating voltage Power consumption Output voltage Max load / channel Max total load Output connection Max cascade Surge protection Clamping voltage Turn on sequence Turn off sequence Step timing Delay off option Delay off timer Switch lock Indicators Dimensions (WxHxD) Weight 230 / 240V ac 50 mW (without load) 230 / 240V ac 6A 15A IEC female socket 2 uts : total 14 channels L-N, L-E, N-E. 870V ac Step 1 to 7 incremental Step 7 to 1 decremental 2 seconds Channel 7 via DIP switch 2 minutes Via front switch AC mains, Ch. on, Lock 482 x 44 x 180 mm 2.7 kg excl. accessories Application Schematic ac output CH.1 LOAD : : : : ac supply CH.7 LOAD ac supply SQ9715 MASTER link cable Units shown in cascade mode with 14 channels in total. Ch 14 is last channel with delay option Control only at Master unit SQ9715 SLAVE CH.8 LOAD : : CH.14 LOAD Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 3.3 kg Regulated 24V DC Power Supply | PS9400 IMPROVED Technical Specifications Input ac voltage Output voltage Rating No load consumption Efficiency Indicators Protections Output DC protection Terminals Dimensions (WxHxD) Weight Packing information Qty per carton : 1 unit WxHxD : 560 x 95 x 295 mm Weight : 3.3 kg 220 ~ 240V ac 24V +/- 1% 4A nominal ; max 4.5A 50 mW 83% AC mains, battery input, DC output Built in surge protection Short circuit Overload (105% ~ 150%) Over voltage (115% ~ 135%) Manual reset circuit breaker Batt input and load ; barrier connector 482 x 44 x 180 mm 2.6 kg PS9400 is a rack mounted 24V DC regulated power pack designed uniquely for PA installations. It comes with built in changeover relay which shall be connected to back up 24V DC to allow continuous and uninterrupted supply to the whole installation whenever the mains failed. Features 4V DC 4A output highly regulated switching power supply Manual reset output circuit breaker protection Built in surge and short circuit protection Back up battery overriding relay Rear View: 45 www.ampereselectronics.com VR7600 & AV7200 amperes Volume Controllers / Patch Features 6 zones with 50 / 100 / 150W 100V line rating for each zone Customised zone rating option available VR7600 - Rack Mounted Zone Volume Controllers VR series is available in three variants with 6 zones at each panel, to be mounted at rack to enable volume of each zone to be controlled or set at the control room. Suitable for 4 wire system : 2 for 100V audio & 2 for 24V DC overriding Built in overriding relay for emergency volume bypass Application Schematic VR should be installed before LS4600 to avoid false fault detection due to variation of impedance whenever volume is adjusted. Technical Specifications POWER AMPLIFIERS PA 2120 120 Watts POWER POWER PA 2120 VR7605 / VR7610 / VR7615 Power rating 50 / 100 / 150W 100V line / zone Overriding voltage 24V DC Overriding current 15 mA per channel Attenuation 6 steps incl. OFF Attenuation / step 6 dB / step Attenuation method Auto transformer Size (W x H x D) 482 x 88 x 60 mm Weight 2.1 / 3.1 / 3.2 kg I PROTECT O SIGNAL -10 dB CLIP SIGNAL -40 dB ZONE SELECTOR 24V DC for emergency override ZS 5121 OVERRIDE 1 2 3 4 5 6 7 SPEAKER ZONE SELECT 8 9 10 11 12 ALL CALL VR7000 SERIES LINE SURV. MENU ENTER PRE NEXT STATUS CH1 CH2 CH3 CH4 CH5 CH6 BUZZER AUTO NORMAL FAULT 24V 100V 100V VOLUME CONTROLS SPEAKERS AV7200 | 100W 100V Line Auto Volume Controller AV7200 is used for controlling speaker volume automatically for a localised area by adjusting the 100V line audio according to the ambient noise. As it varies the volume at 100V instead of sending control signal to the system, it can be easily applied to the existing systems without having to lay new cablings or installing new equipment. Among suitable areas are shopping malls, stations, building lobbies, etc. Features Installation at localised area (at existing volume controller) without additional cable re-run (easily retrofit to existing system) Application Schematic 100V speaker line control with 6 step attenuation Adjustable noise sensing sensitivity POWER AMPLIFIER Built in overriding relay for emergency volume bypass 24V DC for overriding LS4600 (optional) Technical Specifications 100V Line 24V O/Ride A V 7 2 00 24V DC PSU via adaptor A U T O M A T IC V O L U M E C O N T R O LL E R HI M IC LO HI LO S E N S IT IV IT Y 1 2 3 4 5 O U T P U T LE V E L S E N S IT IV IT Y 6 1 O V E R R ID E AV7200 ZONE SPEAKERS 46 A V 7 2 00 A U T O M A T IC V O L U M E C O N T R O LL E R M IC www.ampereselectronics.com 2 3 4 5 O U T P U T LE V E L 6 O V E R R ID E AV7200 ZONE SPEAKERS Power rating Operating voltage Attenuation Emergency overriding Sensitivity adjustment Dimension (W x H x D) Weight (excl. enclosure) 100W 100V line 24V DC : 40 mA 6 steps ; -6 dB per step 24V DC ; 0.15A 2 level 247 x 87 x 50 mm 1.1 kg Speaker Volume Controllers amperes VC7000 & VC8000 Volume Controller / Patch From contemporary to classic design, Amperes offers choices for the installation needs. The variants are in three different designs and available in various ratings, ranging from 5 watts to 150 watts 100V line. They are suitable for 4 wire system installation with built in emergency overriding relay and overriding LED indicator. Features Suitable for 4 wire system : 2 for 100V line , 2 for 24V DC overriding signal Built in overriding relay to allow emergency signal to bypass volume attenuation Overriding LED indicator whenever EM paging is activated 5 preset attenuation with OFF VC7000 - 5 - 150W 100V (86 x 86 mm) Large cable terminal block for ease of termination Technical Specifications Power rating Overriding voltage Overriding current Attenuation Attenuation / step Attenuation method Refer to variants 24V DC 15 mA per channel 6 steps incl. OFF 6 dB / step VC7005 / 7010 / 8010 - Resistive Others - Auto transformer White VC7000 / 8000 - 86 x 86 x 40 mm VC7000A - 70 x 120 x 40 mm VC7805 / 7005 / 7010 - 100 gms VC7030 / 7050 - 248 gms VC7100 / 7150 - 382 gms Colour Size (W x H x D) Weight VC8010 VC8030 VC8050 VC8100 Optional item : Conceal enclosure Surface enclosure 77 x 77 x 60 mm 85 x 85 x 60 mm VC8000 - 5 - 100W 100V (86 x 86 mm) Variants : VP7000 (OPTIONAL) 24V O/R From amplifier localised area 100V VC8000 100V For 70 x 120 faceplate series: Vertical and Horizontal version available - 250 gms - 254 gms - 264 gms - 269 gms Application Schematic 24V DC Override VC7000A - 5 - 100W 100V (70 x 120 mm) VC8000 SPEAKERS loop to next speaker 100V SPEAKERS loop to next speaker 4 wire system installation NOTE : Wall concealed installation shall require back enclosure with depth of min 50 mm from finishing surface for models with auto transformer. Normal electrical back enclosure shall suffice for installation using resistive volume controllers. ie. VC7005 / 7010 / 8010 VC8000 SERIES (86 X 86 mm) 10W 100V Line Resistive VC8010 : 30W 100V Line Auto Trans VC8030 : 50W 100V Line Auto Trans VC8050 : 100W 100V Line Auto Trans VC8100 : VC7000 SERIES (86 x 86 mm) 10W 8 OHM Resistive VC7810 : 5W 100V Line Resistive VC7005 : 10W 100V Line Resistive VC7010 : 30W 100V Line Auto Trans VC7030 : 50W 100V Line Auto Trans VC7050 : 100W 100V Line Auto Trans VC7100 : 150W 100V Line Auto Trans VC7150 : VC7000A SERIES (70 X 120 mm) 10W 100V Line Resistive VC7010A : 30W 100V Line Auto Trans VC7030A : 50W 100V Line Auto Trans VC7050A : 100W 100V Line Auto Trans VC7100A : 47 www.ampereselectronics.com Speaker Patchs Volume Controllers / Patch amperes Introduction VP7501 is used to isolate a group of speakers (meeting room, etc) from central PA system to allow a separate PA amplifier to utilise those local speakers, but can be overrided by main system when a 24V overriding signal is present. VP7810 works similarly but the local speaker is 8 Ohm, ie. setup in hotel room with speaker connected to TV audio output via a mini amplifier. In the event of emergency, it shall allow the incoming 100V line to take over and to match the speaker’s impedance. Features VP7501 - Local Speaker Patch Panel Suitable for 4 wire system : 2 x audio, 2 x 24V DC overriding Built in overriding relay for emergency bypass with LED indicator Also available with 70 x 120 mm front panel Application Schematic 24V DC Override from main PA system VOL.CONTROL patch using 1/4" mono jack LOCAL SPEAKER PATCH IN 100V SPEAKER VOLUME 2 1 OFF 3 4 100V 5 OVERRIDE VP7810 - 8 Ohm Speaker Patch OVERRIDE VP7501 SPEAKER C/W TRANS 100V Technical Specifications Power rating Overriding voltage Patch connection Cablings Size (front panel) Weight (excl. enclosure) Concealed (W x H x D) Surface (W x H x D) VP7501 VP7810 50W 100V line 10W 8 Ohm 24V DC : 15 mA 1/4”phone jack-front patch Hardwired 4 wire system (2 audio ; 2 overriding) 86 x 86 mm 70 x 120 mm face plate available upon request 69 / 215 gms 77 x 77 x 60 mm 85 x 85 x 60 mm audio inputs MIXER AMP (LOCALISED) VP7501 application schematic audio in from TV etc 8 OHM OUT MINI AMP VC7805 VP7810 PA - TV BGM EM OVERRIDE MODULE SPEAKER VOLUME 2 1 OFF 3 4 5 OVERRIDE OVERRIDE 100V output from central PA system 24V DC Override VP7810 application schematic Packing information Carton (W x H x D) : VP7501 / VP7810 : 580 x 510 x 310 mm Weight : VP7501 : 200 g : VP7810 : 300 g Qty : VP7501 / VP7810 : 112 uts per carton 48 www.ampereselectronics.com 4 / 8 OHM SPEAKER Dual Cone Ceiling Speaker Speakers Speaker Volume Controllers amperes CS510 / CS610 : DUAL CONE CEILING SPEAKER W ABS ENCLOSURE Available in 5” and 6” of driver size complete with matching transformer of three tappings ; 1, 3 or 6W. Back enclosure are supplied as integral part of the speakers made from quality ABS plastic. Installation is made easy with its screw mounting mechanism. Packing information CS510A : 850 (W) x 385 (H) x 240 (D) mm : 15 kg : 20 uts per carton CS610A : 685 (W) x 475 (H) x 340 (D) mm : 19.6 kg : 18 uts per carton CS515 : DUAL CONE CEILING SPEAKER W ABS ENCLOSURE CS510A - 5” 6W 100V Line CS610A - 6” 6W 100V Line CS515 is a general purpose 5" 6W 100V line ceiling speakers which comes complete with ABS honeycome grille and back enclosure. It is suitable for BGM and Paging application and suitable for rust prove enviroment. CS606 - 6” 6W 100V Line Packing information CS515 : 850 (W) x 385 (H) x 240 (D) mm : 15 kg : 20 uts per carton CS606 : DUAL CONE CEILING SPEAKER W METAL ENCLOSURE Available in 6” dual cone speaker with back metal enclosure, grill and baffle and multi tap matching transformer of 1.5, 3 and 6W 100V line. This model shall be suitable for installations that demand fire resistant version of dome. CS515 - 5” 6W 100V Line Packing information CS606 : 420 (W) x 220 (H) x 345 (D) mm : 6.5 kg : 6 uts per carton CS343 : WEATHERPROOF CEILING SPEAKER CS343 is driven by a 4” dual cone speaker with built in matching transformer of dual taps of 3 and 6W 100V line. Made of quality ABS enclosure and aluminum grille, it is suitable for high humidity areas, such as bathrooms and salty environment. Though compact in size, it delivers satisfactory sound reproduction with high SPL level, good for listening pleasure as well as paging clarity. Packing information CS343 : 550 (W) x 180 (H) x 465 (D) mm : 9.5 kg : 9 uts per carton CS343 - 4” 6W 100V Line Technical Specifications CS510 SPEAKER Power rating Diameter Cone type Impedance (Ohm) Freq response (+/- 5dB) SPL @ 1W / m (+/- 3dB) 1 KHz Magnet weight TRANSFORMER Tapping (100V line) Primary impedance (Ohm) Secondary impedance (Ohm) PHYSICAL Grille / enclosure Cutting hole dim Overall size (dia x height) Weight Colour CS610 6W 100V line nominal (max 10W) 5” (125 mm) 150 ~ 19 KHz 93 dB 3 oz CS606 6” (150 mm) 120 ~ 19 KHz 92 dB 5.3 oz Dual cone 8 150 ~ 16 KHz 91 dB 2 oz CS515 CS343 5” (125 mm) 4” (100 mm) 150 ~ 17 KHz 92 dB 3 oz 150 - 18 KHz 90 dB 1 / 3 / 6W 10 K / 3.3 K / 1.6 K 1.5 / 3 / 6W 6.7 K / 3.3 K / 1.6 K 8 1.3 / 6W 10 K / 3.67 K / 1.7 K 3 / 6W 3.3K / 1.67 K White metal / ABS white 175 mm 140 mm 230 x 102 mm 177 x 130 mm 785 g 715 g White metal 165 mm 200 x 100 mm 950 g White ABS Plastic 145 mm 175 x 95 mm 600 g Aluminum / ABS 120 mm 140 x 130 mm 900 g 49 www.ampereselectronics.com Co-axial Ceiling Speaker Speakers amperes CS620 / 840 CO-AXIAL CEILING SPEAKER CS620 and 840 meets the requirement of hi fidelity of sound reproduction in areas such as function halls, restaurants and also for sound reinforcement at banquet halls. They are available in 6” and 8” version of speaker driver with tweeter and 100V line matching transformer. Packing information CS620 : 580 (W) x 510 (H) x 310 (D) mm : 20 kg : 7 uts per carton CS840 CS620 / CS840 : 580 (W) x 510 (H) x 310 (D) mm : 13.6 kg : 4 uts per carton CS518 SQUARE CO-AXIAL CEILING SPEAKER CS518 matches other fittings at ceiling where most of them are in square or rectangular shapes. It’s size is almost similar to square shape light fittings and is loaded with co-axial 5” driver, delivering clear and crispy sound. It is suitable for boutiques, residence, offices as well as lobbies. Packing information CS518 : 580(W) x 510 (H) x 310 (D) mm : 17.8 kg : 7 uts per carton CS518 Technical Specifications SPEAKER Power rating Diameter Cone type Impedance Freq response (+/- 5dB) SPL @ 1W / m (+/- 3dB) 1 KHz Magnet weight TRANSFORMER Tapping (100V line) Primary impedance (Ohm) Secondary impedance (Ohm) PHYSICAL Grille / enclosure Cutting hole dim Overall size (dia x height) Weight Colour 50 www.ampereselectronics.com CS620 CS840 CS518 20W 100V 6.5” (165 mm) 40W 100V 8” (200 mm) Co-axial 8 Ohm 90 ~ 19 KHz 90 dB 15 oz 20W 100V 5” (125 mm) 80 ~ 18 KHz 88 dB 10 oz 20W 500 205 mm 240 x 145 mm 2.4 kg 40W 250 8 White metal / ABS white 240 mm 280 x 145 mm 2.9 kg white 100 ~ 18 KHZ 85 dB 10 oz 2.5 / 5 / 10 / 20W 4K / 2K / 1K / 500 150 x 150 mm 180 x 180 x 135 mm 1.8 kg Surface Mount Speaker amperes Speakers SURFACE MOUNT SPEAKER It is constructed with high quality ABS plastic with 4” dual cone speaker driver and multi tapping matching transformer of 1 / 3 / 6 and 10W 100 V line. Suitable for wall and ceiling installation with optional tilt mounting bracket. Available in white colour. BS410 - 4” 10W 100V Packing information BS410 : 550 (W) x 220 (H) x 430 (D) mm : 12 kg : 12 uts per carton SURFACE MOUNT SPEAKER DV410 - 4” 6W 100V A classic yet favourite model which is suitable for installations in small enclosed areas such as staircase, office, etc. Available in white colour with multi tap matching transformer of 1 / 3 / and 6W 100V line, fit for vertical or horizontal installations. Packing information DV410 : 590 (W) x 400 (H) x 305 (D) mm : 15.4 kg : 18 uts per carton SURFACE MOUNT SPEAKER BS506 - 5” 6W 100V Wall mount speaker are suitable for any type of sound reproduction, for both paging and background music. Available in white colour with high effeciency driver and line transformers. Packing information BS410 : 550 (W) x 220 (H) x 430 (D) mm : 12 kg : 12 uts per carton Technical Specifications BS410 DV410 BS506 6W 100V 6W 100V 5” SPEAKER Power rating Diameter Cone type Impedance (Ohm) Freq response (+/- 5dB) SPL @ 1W / m (+/- 3dB) 1 KHz Magnet weight 4 100 ~ 16 KHz 92 dB 7.5 oz Dual Cone 8 100 ~ 18 KHz 90 dB 3.0 oz 8 100 ~ 15 KHz 93 dB 3 oz TRANSFORMER Tapping (100V line) Primary impedance (Ohm) Secondary impedance (Ohm) 1 / 3 / 6 / 10W 10 K / 3.3 K / 1.6 K /1K 4 1 / 3 / 6W 10 K / 3.3 K / 1.6 K 8 1 / 3 / 6W 10 K / 3.3 K / 1.6 K 8 PHYSICAL Grille / enclosure Overall size (WxHxD) Weight Colour 10W 100V 4” ABS ABS with metal grille 172 x 195 x 105 mm 185 x 205 x 90 mm 195 x 215 105 mm 1.1 kg 0.75 kg White 51 www.ampereselectronics.com Full Range Speaker amperes Speakers FS420 & FS640 : FOREGROUND MUSIC SPEAKER Available in 4” and 6” of driver size complete with matching transformer, selectable power switch and mounting bracket. They are suitable for foreground soft music such as restaurants, shops and general sound reinforcement in meeting room, corridors, etc. Packing information FS420 : 440 (W) x 370 (H) x 250 (D) mm : 9.65 kg : 4 uts per carton FS640 : 420 (W) x 345 (H) x 220 (D) mm : 7.30 kg : 2 uts per carton FS338 : FOREGROUND MUSIC SPEAKER FS420 ( Black / White ) FS640 ( Black / White ) 4” 20W 100V 6” 40W 100V FS338 is built as multi purpose speaker, optimising the features of smooth and pleasant outlooks while maintaining the audio performance. Thus by its appearance and sound quality, it can be employed in most indoor venues. It is driven by 2 x 4” PP speakers and a 1” tweeter with 40W 100V line power. It can also be driven directly from audio amplifier with 4 Ohm connections. Multiple power tapping is available via the rotary switch from 5 to 40W 100V line. Installation is rather flexible due to its dual angle mounting bracket. They can be mounted in horizontal or vertical position. If wider coverage is required, then can be installed in horizontal array format, with two, three or 360 degree format via the optional mounting pole. Packing information FS338 : 560 (W) x 295 (H) x 165 (D) mm : 7.6 kg : 2 uts per carton FS340 : FOREGROUND MUSIC SPEAKER FS340 delivers smoothing sound with its 6” driver with tweeter. Available in 40W 100V line with power selector for level adjustment to suit area of installation. It can be installed vertically or horizontally, thanks to its flexible mounting bracket. FS340 FS338 6” 40W 100V 4” 40W 100V Technical Specifications FS420 SPEAKER Power rating Diameter Speaker type Impedance Freq response (+/- 5dB) SPL @ 1W / m (+/- 3dB) 1 KHz TRANSFORMER Tapping (100V line) Primary impedance (Ohm) Secondary impedance (Ohm) PHYSICAL Grille / enclosure Overall size (WxHxD) Weight Colour 52 www.ampereselectronics.com 20W 4” (100 mm) 100 ~ 18 KHz 89 dB 1.25 / 2.5 / 5 / 10 / 20W / 8 4K / 2K / 1K / 500 / 8 Be it a restaurant, pub or cafe, meeting room or lobby, FS340 shall be the exact candidate to choose from. Packing information FS340 : 455 (W) x 385 (H) x 240 (D) mm : 7.8 kg : 2 uts per carton FS340 FS640 FS338 40W 100V 6” (150 mm) 4” x 2 (100 mm) 6” (150 mm) 2 way speaker with tweeter 8 Ohm 70 ~ 18 KHz 70 ~ 16 KHz 87 dB 88 dB 5 / 10 / 20 / 40W / 8 8 5 / 10 / 20 / 40W / 8 2K / 1K / 500 / 250 / 8 5 / 10 / 20 / 40W / 4 2K / 1K / 500 / 250 / 4 4 ABS enclosure with metal grille 170 x 215 x 150 mm 209 x 585 x 195 mm 137 x 385 x 262 mm 215 x 284 x 190 mm 2.2 kg 3.3 kg 3.4 kg 3.5 kg White and Black Black Column Speaker amperes Speakers CL900 | 20 - 60W 100V Line Column Speaker Features Slim design to match environment or hidden from view CL912 - 60W 100V Engineered for speech and BGM clarity CL908 - 40W 100V Technical Specifications Power rating Speaker components Transformer tapping(100V) Primary impedance (Ohm) Sensitivity (1m / 1w) Frequency response Dimension (mm) Material Weight with bracket (kg) CL904 20W 100V 4 x 2” 10 / 20W 1k / 500 87 ± 3dB 350 x 79 x 89 1.4 CL908 40W 100V 8 x 2” 30 / 40W 330 / 250 88 ± 3dB 230 - 16 KHz 567 x 79 x 89 Aluminum 2.35 CL912 60W 100V 12 x 2” 50 / 60W 200 / 166 89 ± 3dB CL904 - 20W 100V 782 x 79 x 89 3.2 Packing information CL904 : 390(W) x 150(H) x 230(D) mm : 3.60 kg : 2 uts per carton CL908 CL912 Built ruggedly with aluminum die extrusion housing and available in 3 power rating of 20 / 40 and 60W 100V line with dual power tapping. : 608(W) x 168(H) x 235(D) mm : 5.55 kg : 2 uts per carton Suitable for classrooms, hyper markets, mosques, ballroom, factories, passenger terminals, exhibition areas etc. : 828(W) x 168(H) x 235(D) mm : 7.80 kg : 2 uts per carton 20 - 40W 100V Line Column Speaker | CH700 CH700 SERIES COLUMN SPEAKER CH740 - Built ruggedly with aluminum die cast housing and available in 3 power rating of 20 / 30 and 40W 100V line with dual power tapping. Suitable for classrooms, hyper markets, mosques, etc. CH730 - 40W 100V 30W 100V Technical Specifications SPEAKER Power rating Diameter Speaker type Impedance Freq response (+/- 5dB) SPL @ 1W / m (+/- 3dB) 1 KHz Magnet weight TRANSFORMER Tapping (100V line) Primary impedance (Ohm) Secondary impedance (Ohm) PHYSICAL Grille / enclosure Overall size (WxHxD) (mm) Weight (kg) Colour CH720 CH730 CH740 20W 100V 2 x 4” 30W 100V 3 x 4” Dual cone 8 Ohm 80 ~ 15 KHz 93 dB 7.5 oz 40W 100V 4 x 4” 85 ~ 15 KHz 91 dB 10 / 20W 1 K / 500 15 / 30W 660 / 330 8 CH720 - 20W 100V 75 ~ 15 KHz 95 dB 20 / 40W 500 / 230 Aluminum / metal grille 145 x 605 x 100 145 x 495 x 100 145 x 400 x 100 4.6 3.7 3.2 Dark grey / front black grille Packing information CH720 : 430 (W) x 310 (H) x 220 (D) mm : 7.1 kg : 2 uts per carton CH730 : 520 (W) x 320(H) x 215 (D) mm : 8.9 kg : 2 uts per carton CH740 : 620 (W) x 310 (H) x 220 (D) mm : 10.5 kg : 2 uts per carton 53 www.ampereselectronics.com PS820 & SG390 Speakers amperes PS820 PENDANT BALL SPEAKER Installations for high ceiling areas without columns, such as warehouses, hypermarkets and large showrooms that require even sound distributions shall select PS820 pendant ball speakers. It is built with 8” speaker of 20W 100V rating, delivering powerful and evenly projected sound with 180° dispersion. PS820 20W 100V Line Packing information PS820 : 310(W) x 310(H) x 300(D) mm : 3 kg : 1 unit per carton SG390 OUTDOOR GARDEN SPEAKER SG390 is the preferred choice for outdoor installations in parks, pool sides, etc, providing excellent music for listening pleasure. With its green outlooks, it blends perfectly to the shrubs, or hidden by leaves or grass. Thereby, its the right candidate to hide the sound source unlike the bulky speakers suspended at poles which may affect the aesthetic value of the environment. Dual purpose It is installed for paging purposes or to provide smooth music at outdoor installations. 360 dispersion It provides an even dispersion of 360. An advantage over conventional speakers that may require at least 3 units for such an angle of coverage. Thus reducing the speaker count. SG390 Powerful sound Available in 40W 100V line input, SG390 shall deliver the punch of sound, smoothness of listening pleasure and clarity of voice announcement. 40W 100V Line Built for all environment High quality materials are used in the construction of the enclosure, which enable the unit to withstand outdoor environment - rain or shine. Packing information SG390 : 345(W) x 390(H) x 345(D) mm : 4.65 kg : 1 unit per carton Technical Specifications PS820 Power rating Power tapping (100V line) Speaker diameter Speaker type Primary impedance (Ohm) Frequency response SPL (1w/m @ 1 kHz) Construction material Colour Dimensions Weight 54 www.ampereselectronics.com 20W 100V line 5 / 10 / 20W 8” (200 mm) 2K / 1K / 500 80 - 18 KHz 91 dB White 254 diameter (mm) 2.2 kg SG390 Co-axial ABS 40W 100V line 20 / 40W 5” (125 mm) 540 / 270 70Hz - 16 KHz 84 dB Green 340 dia x 134 height (mm) 3.6kg Horn & Projection Speakers amperes SP219 : UNIDIRECTIONAL SOUND PROJECTOR SP219 is used when a more directional sound projection is required for areas such as at narrow corridors, tunnels, walkways, etc. It has aluminum body with metal grille and available with standard power rating of 10W 100V line. Mounting position can be either at wall or hanged from ceiling. Packing information SP219 : 550 (W) x 180 (H) x 465 (D) mm : 9.6 kg : 4 uts per carton SP219 : 10W 100V LINE SP319 : BIDIRECTIONAL SOUND PROJECTOR It is suitable for narrow corridors, or walkways that requires sound reproduction in two direction. Installing bi directional speakers may reduce the speaker counts and thus lowering installation and cabling costs. Packing information SP319 : 550 (W) x 180 (H) x 465 (D) mm : 12.8 kg : 5 uts per carton SP319 : 10W 100V LINE BIDIRECTIONAL HS725 : WEATHERPROOF CLEAR HORN SPEAKER HS725 meets the requirement of speakers with horn characteristics and yet delivers sound with music clarity. It is suitable for installations in almost any areas particularly outdoors, able to withstand rain and shine. Packing information HS725 : 440 (W) x 250 (H) x 370 (D) mm : 5.1 kg : 1 unit per box HS725 : 30W 100V LINE Technical Specifications HS725 SP319 SP219 Power rating Power tapping (100V Line) Speaker Primary impedance (Ohm) Secondary impedance (Ohm) Frequency response (+/-3 dB @ 1 KHz) SPL (1W / m @ 1 KHz) Grille / enclosure Overall size Weight Colour 5” 2.9 kg 10W 100V Fixed at 10W 1K 8 130 ~ 15 KHz 91 dB Mild Steel / Aluminum 138 (Dia) x 205 (H) mm White 2 x 5” 3.5 kg HS725 30W 100V line 30 / 15 / 7.5 / 3.8W 5” (125mm) 333 / 667 / 1.3 K / 2.6 K 8 100 ~ 10 KHz 90 dB Aluminum / ABS 366 (W) x 172 (H) x 272 (D) mm 3 kg Light grey 55 www.ampereselectronics.com Horn Speaker Speakers amperes HS815 8” 15W 100V LINE HS830 12” 30W 100V LINE HS815 & HS830 : HORN SPEAKER WITH ROUND FLARE Both models are constructed using rounded aluminum flare of 8” (HS815) and 12” (HS830) with multiple power selection via rotary switch. Suitable for schools, mosques, car parks, factories at indoor or under shade installations and that requires omni direction sound broadcast. Packing information HS815 : 695 (W) x 480 (H) x 520 (D) mm : 23 kg : 12 uts per carton HS830 : 665 (W) x 665 (H) x 355 (D) mm : 10.6 kg : 4 uts per carton HS880 : HIGH POWER HORN SPEAKER HS880 20” 80W 100V LINE Constructed using rounded aluminum flare of 20” (HS880) with multiple power selection. It is suitable for schools, mosques, fencing perimeters etc, which requires loud and clear broadcast. Packing information HS880 : 585 (W) x 390 (H) x 560 (D) mm : 6.2 kg : 1 unit per box HS820 : HORN SPEAKER WITH RECT. FLARE HS820 6“ X 8” 15W 100V LINE IP65 Constructed with high impact ABS flares rectangular shape to suit installation sites where pattern of broadcast shall be controlled, such as low level car parks, corridors, etc. Suitable for indoor or outdoor sites with IP65 rating. Packing information HS820 : 550 (W) x 180 (H) x 465 (D) mm : 14.2 kg : 8 uts per carton Technical Specifications Power rating Power tapping (W) Primary Impedance (Ohm) Secondary impedance (Ohm) Frequency response (+/-5 dB) @ 1KHz, 1W SPL (1W / m @ 1 KHz) Flare material Flare dimension Driver enclosure Overall size (dia x height) Weight Colour 56 www.ampereselectronics.com HS815 15W 100V 1 / 3 / 5 / 10 / 15 670 1K 2K 3.3 K 10 K 350 ~ 7 KHz 103 dB 8” round 210 x 240 mm 1.55 kg 8 ABS HS830 30W 100V 3 / 5 / 10 / 15 / 30 330 670 1K 2K 3.3 K 300 ~ 10 KHz 105 dB Aluminum 12” round 310 x 325 mm 1.85 kg Beige HS880 80W 100V 20 / 40 / 60 / 80 500 250 160 125 16 160 ~ 6 KHz 110 dB HS820 15W 100V 1.9 / 3.8 / 7.5 / 15 5.26 K 2.63 K 1.33 K 667 8 250 ~ 8 KHz 105 dB 20” round Aluminum Diecast 504 x 335 mm 3.35 kg 160 x 220 mm ABS 222(W) x 162(H) x 232(D) mm 1.5 kg ABS White amperes All models with 60 mm depth, suitable for volume controllers with auto transformers. Enclosures are optional items and to be ordered separately from volume controllers / patch panels. Accessories Complementary Products ENCLOSURES EC7012 : 70 X 120 mm Back enclosure for concealed mounting (steel) ES7012 : 70 x 120 mm Back enclosure for surface mounting (steel) EA9090 : 86 x 86 mm Back enclosure for concealed mounting (ABS) ES9090 : 86 x 86 mm Back enclosure for surface mounting (steel) Quality XLR connectors are used in the above series. Other brands of inlets are available upon request. PATCH PANELS MR5000 : 5 Way rack mounted female XLR patch panel MR1000 : 10 Way rack mounted female XLR patch panel MP1000 : Single inlet wall mounted female XLR patch panel MP2000 : Double inlet wall mounted female XLR patch panel Available with standard Amperes mounting ears for harmonious look with other amperes equipments. RACK PANELS Panels are available in black powder epoxy coating. BP1000 : 1 hu blank panel BP2000 : 2 hu blank panel VP1000 : 1 hu ventilation panel VP2000 : 2 hu ventilation panel Regulated power adaptor for powering single unit of equipment. Equipments are not supplied with power adaptor and are to be ordered separately. POWER SUPPLY For larger system, we recommend that proper DC supply to be used with relay changeover for DC back up supply. ie. Amperes PS9400. PS1205 : 12V 0.5A ac / dc regulated power adaptor PS2405 : 24V 0.5A ac / dc regulated power adaptor PS9000 : 24V 4.5A dc switching power supply SLA batteries are sold in blocks of 24V ( 2 x 12V block ). Above are common ratings widely used. Other ratings are available upon request. SLA BATTERIES We recommend that Constant Voltage with auto current reducing charger to be used, ie. Amperes BC9740. MS12 - 26 MS12 - 40 MS12 - 65 MS12 - 100 : 12V 26 Ah Maintenance free SLA battery : 12V 40 Ah Maintenance free SLA battery : 12V 65 Ah Maintenance free SLA battery : 12V 100 Ah Maintenance free SLA battery DAEWOO12 - 65 : 12V 65 Ah Sealed rechargeable battery DAEWOO12 - 100 : 12V 100 Ah Sealed rechargeable battery Fiber optic converter for IP Paging application ( RJ45 to Fiber ) available in single and multimode fiber cabling. Operates on 12V DC with power supply adaptor provided. HTB110 : Multimode fiber connection ( 2 KM ) SC/ST connectors HTB110S: Single mode fiber connection ( 25 KM ) SC connectors Physical dimensions : 26 (H) x 71 (W) x 97 (D) mm FIBER OPTIC CONVERTER 57 www.ampereselectronics.com Technical Info amperes The criterias to be considered in determining the number of speaker required in any installation shall include:- Ceiling speaker Ceiling 4m 1) The ceiling height 2) Acoustical factor of the environment 3) Type of speakers, eg. dispersion angle and SPL level. 4) Expected environment such as factory, office or shopping complex. 3m Hearing level 3.5m 2m coverage angle In order to hear properly, the sound source from speaker shall be 6 dB above the background noise. 1m If the background noise is around 70 dB, such as in a shopping area with average crowd, the person shall be listening to the speaker sound at approximately 76 dB, at around 1.5 to 2m above floor level. Floor Level If the power input is 3W, the SPL ( 1KHz ) at 2 m from speaker shall be approximately 93 dB. With music source, the average SPL shall be 3 dB below ; thereby the hearing shall be around 89 dB, which is rather comfortable level in a shopping mall. Effective dispersion radius From this, the coverage area can be estimated ; ie. approximately 7m diameter or 38 sq m. Further to this, the distance of speaker can be ascertained by dividing the area of the mall to the area of coverage by each speaker. FLOOR MAPPING A general guide to calculate speaker quantity of a floor area. Ceiling height, dispersion angle and speaker characteristics determine the dispersion radius. 4m 3m 2m 1m Point of Source Distance in Metre 93 dB (Max 102 dB) 87 dB (Max 96 dB) 81 dB (Max 90 dB) 78 dB (Max 84 dB) SPL CHART SPL VS DISTANCE It tells the frequency response of a speaker, measured at 1W / m, +/- 3dB at 1 KHz reference point. A general guideline showing the drop of SPL level over distance, measured in meter. POLAR CHART Shows the effective dispersion angle of a speaker. Full 360 deg chart is often used to check full angular characteristics of speaker. POSSIBLE CAUSE OF SPEAKER DAMAGE Speaker may be damaged while in operation and can be associated to excessive power delivery in appropriate frequencies the driver or due to natural disaster such as lightning strike. To prevent or at least to pro long the speaker lifespan the followings should be taken into consideration:Avoid excessive input power to speakers Ensure audio signal delivered is within the frequency baudpass of the speaker ( e.g. sub bass) Do not allow amplifier to clip, ie ensure power rating of amplifier is higher than the total load The amplifier with DC output protection, and preferably with high pass and low pass filters 58 www.ampereselectronics.com Technical Info amperes CALCULATING BACK UP BATTERY CAPACITY CORRECT WAY OF POWERING EQUIPMENT WITH 24V DC For most commercial installations, it is a requirement by local authority that the PA system must be able to operate during power failure. The means for back up supply to the system can be from building’s standby generator or via standalone back up power supply bank ie. Batteries. It is a misinformed idea to save some equipment cost in powering up equipment with 24V DC by using voltage output from battery charger instead of a 24V DC power supply unit or adaptor. It shall damage the equipment concerned as normally they can operate in the range of 10% voltage tolerance and anything above that shall stress the power regulating circuitries. Not only it would shorten the life span but excessive heat would be generated. Batteries can be NiCd or usually SLA type. Steps below provide a simple calculation method on the capacity of batteries required (24V). Step 1 : Sum up total current drawn in the system and operating period required using back up batteries. ie. Total current drawn under 24V supply is 30A and 2 hrs of full load operation is required Capacity C1 : 30 x 2 = 60 Ah Step 2 : Residual voltage percentage to remain at batteries to avoid total discharge, which may cause permanent damage to the cells. ( Refer to manufacturer’s data for safe value ) Voltage from battery charger is normally around 27 to 28V DC whereas from power supply unit ie. Amperes PS9400 is regulated at 24V DC. Thereby it is highly recommended to use suitable regulated power supply unit for operation. 20V DC 24V DC 26V DC ie. 30% Voltage to remain Capacity C2 : 60 / 0.7 = 85.7 Ah Step 3 : Determine optimum discharge rate. Discharge rate differs according to the battery capacity. ( Refer to manufacturer’s data ) PS9400 ie. If it is recommended to draw 5 amp / hour from a battery Capacity C3 : 85.7 / 0.5 = 171.4 Ah Step 4 : BC9740 27.8V DC Duty cycle may differ according to type of load. Music broadcast has lower duty cycle as compared to siren. Using a factor of 20% for music, ie. 20% of current shall be drawn in an hour ie. duty cycle = 20% BATTERY CAPACITY REQUIRED : 171.4 x 0.2 = 34.28 Ah Thereby the nearest standard capacity available is 40 Ah, which would be used for the system. A calculation table is available in Technical Section of www.ampereselectronics.com SOURCE OF INFO : VARIOUS First Digit ( Protection fr. Solid Object) Second Digit ( Protection from liquid) 0 No Protection 0 No Protection 1 Solid object of up to 50 mm and above 1 Vertically falling water drops 2 Solid object of up to 12 mm and above 2 Water spray with 15 vertical angle 3 Solid object of up to 2.5 mm and above 3 Water spray with 60 vertical angle 4 Solid object of up to 1 mm and above 4 Water spray with full all direction with allowance 5 Dust with no harmful deposits 5 Low pressure water jet from all direction 6 Full protection from dust 6 High pressure water jet from all direction 7 Temporary immersion in water 8 Long immersion in water IP RATINGS Ingress Protection up is a classification to indicate the degree of protection of enclosures ( such as speakers ) against penetration of solid particles and moisture. It is usually stated in two digits, IP54, which the first digit refers to protection against solid object and the second digit for protection from moisture. Ref Standards : IEC 60529 SOURCE OF INFO : VARIOUS V 59 www.ampereselectronics.com 15th Year Of Excellence Due to our continuous product improvement policy, amperes electronics reserves the rights to change the specifications, features and artwork without prior notifications. While every care had been taken to ensure the information contained in this catalogue is correct at the time of printing, some minor errors may be unintentionally inserted. Kindly contact us for clarifications should any doubt arises. Amperes shall be indemnified against any claims caused by any errors in the printing. The “amperes” logo is a registered trademark of Amperes Electronics Sdn Bhd (Co No:509025-X) Malaysia. Copyrights Reserved @2015 amperes Precision Design, Absolute Confidence PUBLIC ADDRESS SYSTEM C O M M E R C I A L I N S TA L L AT I O N S 20 15 16 ISO 9001: 2008 Design & Manufacture of Public Address Equipment and Systems Certificate No. 16895 / A / 0001 / UK / En www.ampereselectronics.com Related materials such as engineer’s specifications, instruction manuals, product drawings and catalogue in softcopy are available in CD-ROM and website. Models which are not available in this version of catalogue are considered discontinued from production or latest products which are yet launched at the time of printing. Kindly contact your nearest distributor or e-mail to us for further information. Distributed By :