ST. TAMMANY PARISH PATRICIA P. BRISTER PARISH PRESIDENT March 23, 2016 Please find the following addendum to the below mentioned BID. Addendum No.: 3 Bid#: 404-40-16-11-2 Project Name: Statewide Generator Program Bid Due Date: Tuesday, March 29, 2016 GENERAL INFORMATION: 1. Replace Section 04 “Pricing Sheet” with Section 04 “LA Public Bid Form” (Attached) ATTACHMENTS: 1. Section 04 LA Public Bid Form.pdf << End of Addendum #3>> PROCUREMENT DEPARTMENT P.O. BOX 628 | COVINGTON, LOUISIANA | 70434 | PROCUREMENT@STPGOV.ORG | 985-898-2520 WWW.STPGOV.ORG Section 04 LOUISIANA UNIFORM PUBLIC WORK BID FORM TO: _St. Tammany Parish Government_____________ 21454 Koop Drive, Suite 2F________________ Mandeville, LA 70471______ ________________ _______________________________________ BID FOR:_Statewide Generator Program Bid#404-40-16-11-2 _______________________________________ _______________________________________ (Owner to provide name of project and other identifying (Owner to provide name and address of owner) information) The undersigned bidder hereby declares and represents that she/he; a) has carefully examined and understands the Bidding Documents, b) has not received, relied on, or based his bid on any verbal instructions contrary to the Bidding Documents or any addenda, c) has personally inspected and is familiar with the project site, and hereby proposes to provide all labor, materials, tools, appliances and facilities as required to perform, in a workmanlike manner, all work and services for the construction and completion of the referenced project, all in strict accordance with the Bidding Documents prepared by:_ST. Tammany Parish Government and dated: _January 15, 2016 (Owner to provide name of entity preparing bidding documents.) Bidders must acknowledge all addenda. The Bidder acknowledges receipt of the following ADDENDA: (Enter the number the Designer has assigned to each of the addenda that the Bidder is acknowledging) __________________________________________ . TOTAL BASE BID: For all work required by the Bidding Documents (including any and all unit prices designated “Base Bid” * but not alternates) the sum of: Dollars ($ ) ALTERNATES: For any and all work required by the Bidding Documents for Alternates including any and all unit prices designated as alternates in the unit price description. Alternate No. 1 N/A (Owner to provide description of alternate and state whether add or deduct) for the lump sum of: Dollars ($ ) Alternate No. 2 N/A (Owner to provide description of alternate and state whether add or deduct) for the lump sum of: Dollars ($ ) Alternate No. 3 N/A (Owner to provide description of alternate and state whether add or deduct) for the lump sum of: Dollars ($ ) NAME OF BIDDER: ADDRESS OF BIDDER: LOUISIANA CONTRACTOR’S LICENSE NUMBER: NAME OF AUTHORIZED SIGNATORY OF BIDDER: TITLE OF AUTHORIZED SIGNATORY OF BIDDER: SIGNATURE OF AUTHORIZED SIGNATORY OF BIDDER **: DATE: _______________________ * The Unit Price Form shall be used if the contract includes unit prices. Otherwise it is not required and need not be included with the form. The number of unit prices that may be included is not limited and additional sheets may be included if needed. ** If someone other than a corporate officer signs for the Bidder/Contractor, a copy of a corporate resolution or other signature authorization shall be required for submission of bid. Failure to include a copy of the appropriate signature authorization, if required, may result in the rejection of the bid unless bidder has complied with La. R.S. 38:2212(B)5. BID SECURITY in the form of a bid bond, certified check or cashier’s check as prescribed by LA RS 38:2218.A is attached to and made a part of this bid. ST. TAMMANY PARISH PATRICIA P. BRISTER PARISH PRESIDENT March 18, 2016 Please find the following addendum to the below mentioned BID. Addendum No.: 2 Bid#: 404-40-16-11-2 Project Name: Statewide Generator Program Bid Due Date: Tuesday, March 29, 2016 GENERAL INFORMATION: 1. Kohler Generator has been approved as an equal. (Attached) 2. ASKA Generator and ASCO Switch have been approved as an equal. (Attached) QUESTIONS & ANSWERS: Question #1: I saw the Liquidated Damages of $500 per day. However, I can’t find the completion time for the project to know when the LDs will kick in. Can you please let me know the completion time so I can provide to my surety? Answer #1: The projects will take place during the summer months due to the locations being at active schools in the Parish. The students will be out of school from May 27th – August 12th, 2016 and the installation will occur during that timeframe. The generators will need to be prepared for delivery no later than 13 weeks from the issuance of the notice to proceed. We reserve the right to extend to liquidated damages timeframe if realtime conditions present obstacles that could not make it possible. PROCUREMENT DEPARTMENT P.O. BOX 628 | COVINGTON, LOUISIANA | 70434 | PROCUREMENT@STPGOV.ORG | 985-898-2520 WWW.STPGOV.ORG Question #2: Is there any information on where the NEMA 1 Automatic Transfer Switch is to be installed? It will need to be installed inside a building and the contractor is required to set this piece of equipment in place. Answer #2: Since this ATS is located indoors, the winning bidder will only be responsible for delivering the NEMA 1 Automatic Transfer Switch to the jobsite. The construction contractor will be responsible for storing and installing the ATS. Question #3: Please clarify that the contractor is not responsible to refill the fuel tank after load bank test. Answer #3: The Generator vendor will be responsible for a full tank of diesel after the completion of the start-up and 4 hour load bank test on the new generators. Question #4: Please clarify whether the fuel tank needs to be a 24 hour tank or have a 1000 gallon capacity. Answer #4: The required capacity of the generators sub base fuel tank is 1000 gallons. Question #5: One question I need clarification on. Under the section for the sound attenuated enclosure. I believe it reads 73 dba at 23 feet under no load and 86.1 dba at 23 feet under full load. Is this correct? Answer #5: The bid requirement for sound attenuation on the generator is 73 dba at 23 feet under no load and 86.1 dba at 23 feet under full load. ATTACHMENTS: 1. Kholer Generator Specifications.pdf 2. ASKA Generator and ASCO Switch.pdf << End of Addendum #2>> ANTHONY SMITH , DIRECTOR | PROCUREMENT P.O. BOX 628 | COVINGTON, LOUISIANA | 70434 | PURCHASING@STPGOV.ORG | 985-898-2520 WWW.STPGOV.ORG Attachment 1 Industrial Generator Set Accessories Generator Set Controller Kohlerr Decision-Makerr 550 Controller General Description and Function The Decision-Makerr 550 generator set controller provides advanced control, system monitoring, and system diagnostics for optimum performance and compatibility with selected engine Electronic Control Modules (ECM). ECM models only: The Decision-Makerr 550 controller directly communicates with the ECM to monitor engine parameters and diagnose engine problems (see Controller Diagnostics for details). Standard Features D A digital display and keypad provide access to data. The display provides complete and understandable information, and the keypad allows easy local access. D Measurements selectable in metric or English units. D The controller can communicate directly with a personal computer via a network or via a modem configuration. D The controller supports Modbusr protocol. Use with serial bus or Ethernet networks. (Ethernet requires an external Modbusr/Ethernet converter module.) D Integrated voltage regulator providing 0.25% regulation. D Built-in alternator thermal overload protection. D A lockout keyswitch meets appropriate local code requirements. Decision-Makerr 550 Optional Features D Monitor III, an optional menu-driven Windowsr-based PC software, monitors engine and alternator parameters and also provides control capability. See G6-76 spec sheet for more information. D Menu 15 (Protective Relays) is required for optional protective functions and is only available with the Kohler PD-Series switchgear. Modbusr is a registered trademark of Schneider Electric. Windowsr is a registered trademark of Microsoft Corporation. G6-46 12/15o Page 1 15 Protective Relays Decision-Makerr 550 Controller Controller Features NFPA Requirements Decision-Makerr 550—Software Version 2.70 or higher Specifications D D D D D D Power source with circuit protection: 12- or 24-volt DC Power drain: 700 milliamps (or 400 milliamps without panel lamps) Humidity range: 5% to 95% noncondensing Operating temperature range: --40C to +70C (--40F to +158F) Storage temperature range: --40C to +85C (--40F to +185F) Standards: d NFPA 99 d NFPA 110, Level 1 d CSA 282-09 d UL 508 D D D D D Vacuum fluorescent display Environmentally sealed 16-button membrane keypad LED status indicating lights Three-position (run, off/reset, auto) keyswitch Latch-type emergency stop switch with International Electromechanical Commission (IEC) yellow ring identification Alarm horn Fuse-protected battery circuits Controller mounts locally or remotely up to a distance of 12 m (40 ft.) and viewed from one of four positions Dimensions—W x H x D, 460 x 275 x 291 mm (18.15 x 10.8 x 11.47 in.) Hardware Features D D D D In order to meet NFPA 110, Level 1 requirements, the generator set controller monitors the engine/generator functions and faults shown below. NFPA 110 Common Alarm D Engine functions: d Overcrank d Low coolant temperature warning d High coolant temperature warning d High coolant temperature shutdown d Low oil pressure shutdown d Low oil pressure warning d Overspeed d Low fuel (level or pressure) * d Low coolant level d EPS supplying load d High battery voltage * d Low battery voltage * d Air damper indicator D General functions: d Master switch not in auto d Battery charger fault * d Lamp test d Contacts for local and remote common alarm d Audible alarm silence switch d Remote emergency stop * Function requires optional input sensors or kits and is engine dependent, see Controller Displays as Provided by the Engine ECM. G6-46 12/15o Page 2 Controller Functions The control functions apply to both the ECM and non-ECM equipped models unless noted otherwise. D AC Output Voltage Adjustment The voltage adjustment provides keypad adjustment in 0.1 volt increments of the average line-to-line AC output voltage with a maximum adjustment of 10% of the system voltage. D Master Switch Fault The generator set master switch has fault detection at four levels: 1) master switch to off, 2) master switch open, 3) master switch error, and 4) master switch not in auto. Each of these faults/ warnings provides local display, alarm horn on, and activates a relay driver output (RDO). By placing the master switch to the off/reset position, all generator set faults can be reset. D Alternator Protection The controller firmware provides generator set overload and short circuit protection matched to each alternator for the particular voltage/phase configuration. D Modbusr Interface The Modbusr interface provides industry standard open protocol for communication between the generator set controller and other devices or for network communications. D Automatic Restart The controller automatic restart feature initiates the start routine and recrank when the generator set slows to less than 390 rpm after a failed start attempt. D Number of Starts Total number of generator set successful starts is recorded and displayed on the local display and remote PC monitor. This information is a resettable and total record. D Battleswitch (Fault Shutdown Override Switch) The battleswitch input provides the ability to override the fault shutdowns except emergency stop and overspeed shutdown in emergency situations and during generator set troubleshooting. D Programming Access The setup access and programming information is password protected. When locally accessing programming information, the PM (programming mode) LED flashes. When remotely accessing programming information, the PM LED is steady. D Clock and Calendar Real-time clock and calendar functions time stamp shutdowns for local display and remote monitor. Also use these functions to determine the generator set start date and days of operation. D Cooldown Temperature Override This feature provides the ability to bypass (override) the cooldown temperature shutdown and force the generator set to run for the full engine cooldown time delay. Also see Time Delay Engine Cooldown (TDEC). D Cyclic Cranking The controller has programmable cyclic cranking. The customer selects the number of crank cycles (1--6) and the crank time from 10 to 30 seconds. The crank disconnect depends upon the speed sensor input information or the generator frequency information. The default cyclic crank setting is 15 seconds on, 15 seconds off for three cycles. D Digital Voltage Regulator The digital voltage regulator provides 0.25% no-load to full-load regulation. D Display Power Shutdown To conserve battery power, the display turns off after 5 minutes of inactivity. Pressing any keypad button activates the display. D ECM Communication The controller monitors ECM communication links and provides fault detection for oil pressure signal loss, coolant temperature signal loss, and ECM communication loss. Each of these faults provides local display, alarm horn ON, and relay driver output (RDO) on ECM models only. See Controller Diagnostics following for additional information. D Idle Speed Function Idle speed function provides the ability to start and run the engine at idle speed for a selectable time period. The engine will go to normal speed should the temperature reach warm-up before the time delay is complete. D Lamp Test Keypad switch verifies functionality of the indicator LEDs, alarm horn, and digital display. D Programmed Run The programmed run function provides user-selectable time for a one-time exercising of the generator set. The controller does not provide weekly scheduled exercise periods. D Remote Reset The remote reset function resets faults and allows restarting of the generator set without going to the master switch off/reset position. The remote reset function is initiated via the remote reset digital input. D Running Time Hourmeter The running time hourmeter function is available on the local display and remote monitor. The information displayed uses real time loaded and unloaded run time as an actual and resettable record. D Self-Test The controller has memory protection and a microprocessor self-test. D Starting Aid The starting aid feature provides control for an ether injection system. This setup has adjustable on time before engine crank from 0 to 10 seconds. This feature is also part of the remote communication option. D Time Delay Engine Cooldown (TDEC) The TDEC provides a user-selectable time delay before the generator set shuts down. If the engine is above the preset temperature and unit is signalled to shut down, unit will continue to run for the duration of the TDEC. If the engine is at or below the preset temperature and unit is signalled to shut down or the TDEC is running, unit will shut down without waiting for the time delay to expire. Also see Cooldown Temperature Override. D Time Delay Engine Start (TDES) The TDES provides a user-selectable time delay before the generator set starts. Modbusr is a registered trademark of Schneider Electric. D Load Shed The load shed function provides a load control output (RDO) with user-selectable load shed level. G6-46 12/15o Page 3 Controller Diagnostics The controller features warnings and shutdowns as text messages on the vacuum fluorescent display. See the table below. Warnings show yellow LED and signal an impending problem. Shutdowns show red LED and stop the generator set. User-Defined Common Fault and Status. The user customizes outputs through a menu of warnings, shutdowns, and status conditions. User defines up to 31 relay driver outputs (RDOs) (relays not included). Note: Menu 15 features are available by purchasing the paralleling switchgear option. Warning Function Engine Protection Air damper control, if equipped Air damper indicator, if equipped Coolant temp. signal loss High battery voltage High coolant temperature High oil temp. shutdown Low battery voltage Low coolant level Low coolant temperature Low fuel level (diesel) * Low fuel pressure (gas) * Low oil pressure Oil pressure signal loss Overcrank Overspeed Speed sensor fault Starting aid Weak battery General Protection Auxiliary inputs 0--5 VDC— up to 7 analog Auxiliary inputs— up to 21 digital Battery charger fault * Defined common fault [ EEPROM write failure Emergency stop Engine cooldown delay Engine start delay EPS supplying load Internal fault Load shed kW overload X X Shutdown UserUser Function Defined RDOs X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Note: The available user inputs are dependent on factory reserved inputs for specific engine types, engine controls, and paralleling applications. Warning Shutdown UserUser Function Function Defined RDOs Load shed underfrequency X X X Master switch error X X X Master switch not in auto X X X Master switch open X X X Master switch to off X X X NFPA 110 common alarm X X SCRDO’s 1--4 (software X X controlled RDOs) System ready (status) X X Alternator Protection AC sensing loss X X X X Critical overvoltage X X X Generator running X X Ground fault * X X X Locked rotor X X X AC Protection (includes Menu 15 Enabled Enhancements) Alternator protection (short X X X circuit and overload) Breaker trip ] X Common protective relay X X output In synchronization ] X Loss of field (reverse VAR) X X X Overcurrent X X X X Overfrequency X X X Overpower X X X Overvoltage X X X Reverse power X X X Underfrequency X X X Undervoltage X X X * Function requires optional input sensors or kits and is engine dependent, see Controller Displays as Provided by the Engine ECM. [ Factory default settings for the defined common fault are emergency stop, high coolant temperature shutdown, low oil pressure shutdown, overcrank, and overspeed. ] Factory set inputs that are fixed and not user changeable. Controller Displays as Provided by the Engine ECM (availability subject to change by the engine manufacturer) Display GM/PSI Doosan John Deere (JDEC) Volvo (EMS II) Volvo (EDC III) DD/MTU (ADEC) Ambient temperature X Charge air pressure X X X X X Charge air temperature X X X X X Coolant level X X X Coolant pressure X X Coolant temperature X X X X X X Crankcase pressure X X ECM battery voltage X X X ECM fault codes X X X X X X ECM serial number X Engine model number X X Engine serial number X X Engine speed X X X X X X Fuel pressure X X Fuel rate X X X X X X Fuel temperature X X X X Oil level X Oil pressure X X X X X X Oil temperature X X X Trip fuel X X X NOTE: 40--60REOZK (Kohler KDI engines) do not include an ECM as standard equipment. REOZMD/ROZMC (Mitsubishi engines) have an ECM but do not send signals to the generator set controller. G6-46 12/15o Page 4 Controller Monitoring Standard Equipment and Features D Alarm horn D Indicators: d Not in auto (yellow) d Program mode (yellow) d System ready (green) d System shutdown (red) d System warning (yellow) D Switches and standard features: d Keypad, 16-button multi-function sealed membrane d Lamp test d Keyswitch, auto, off/reset, run (engine start) d Switch, emergency stop (normally closed contacts) D Vacuum fluorescent display with two lines of 20 characters Displays Some engine displays are dependent upon enhanced electronic engine control availability. D Engine monitoring data (metric or English units): d Battery voltage d Engine model number [ d Engine serial number [ d Engine speed d Engine start countdown d ECM—battery voltage [ d ECM—fault codes d ECM—serial number [ d Fuel rate d Level—coolant [ d Level—oil [ d Pressure—crankcase [ d Pressure—charge air [ d Pressure—coolant [ d Pressure—fuel d Pressure—oil d Rpm d Temperature—ambient [ d Temperature—charge air [ d Temperature—coolant d Temperature—fuel [ d Temperature—oil [ d Trip fuel [ D Engine setpoints d Coolant—high temperature shutdown and warning setpoints d Oil—low pressure shutdown and warning setpoints d Temperature—engine cooled down setpoint d Temperature—engine warmed up setpoint D Generator monitoring data: d Current (L1, L2, L3), 0.25% accuracy d Frequency, 0.5% accuracy d Kilowatts, total per phase (L1, L2, L3), 0.5% accuracy d KVA, total per phase (L1, L2, L3), 0.5% accuracy d KVAR, total absorbing/generating per phase (L1, L2, L3), 0.5% accuracy d Percent alternator duty level (actual load kW/standby kW rating) d Power factor per phase, leading/lagging d Voltage (line-to-line, line-to-neutral for all phases), 0.25% accuracy D Operational records: d Event history (stores up to 100 system events) d Last start date d Number of starts d Number of starts since last maintenance d Operating days since last maintenance d Operating mode—standby or prime power d Run time (total, loaded and unloaded hours, and total kW hours) d Run time since maintenance (total, loaded, and unloaded hours and total kW hours) d System shutdowns d System warnings d Time, date, and day of week D Time delays—general: d Crank cycles for on/pause d Crank cycles for overcrank shutdown d Engine cooldown d Engine start d Load shed d Voltage, over- and underd Starting aid D Time delays—paralleling relays (PR) for optional switchgear applications: d Current—over (PR) d Current—over shutdown d Frequency—over- and under- (PR and shutdown) d Loss of field (PR and shutdown) d Loss of field shutdown (PR) d Power—over (PR) d Power—over shutdown d Reverse power (PR) d Reverse power shutdown d Synch matching—frequency, phase, voltage d Voltage—over- and under- (PR and shutdown) D System parameters: d Alternator number d Current, rated (based on kW, voltage, connection settings) d Frequency d Generator set model number d Generator set serial number d Generator set spec number d Rating, kW d Phase, single and three (wye or delta) d Voltage, AC d Voltage configuration, wye or delta Inputs D Customer and remote inputs: d Analog inputs 0--5 VDC (up to 7 user-defined analog inputs with multiple shutdown and warning levels) d Digital contact inputs (up to 21 user-defined digital inputs with shutdown or warning levels) d Ground fault detector * d Remote emergency stop d Remote reset d Remote 2-wire start D Digital inputs (standard): d Air damper fault, if equipped d Battery charger fault * d Battleswitch d Emergency stop d Field overvoltage (350 kW and higher) d High oil temperature d Idle mode active (ECM models only) * d Low coolant level d Low coolant temperature d Low fuel warning * d Low fuel shutdown * D Switchgear inputs in Menu 15 (to interface with switchgear system): d Circuit breaker closed d Enable synch d Lockout shutdown d Remote reset d Remote shutdown d VAR/PF mode selection d Voltage—raise/lower (or VAR/PF raise/lower in VAR/PF mode) Outputs See the Fault Diagnostics section for a breakdown of the available shutdown and warning functions. D Thirty-one user-defined relay driver outputs (relays not included) d Fifteen NFPA 110 faults d Defined common faults Communication D RS-485 connector for Modbusr RTU communication port D RS-232 connector for a PC or modem (optional software required) D SAE J1939 connector for the engine ECM (engine control module) * Function requires optional input sensors or kits and is engine dependent; see Controller Displays as Provided by the Engine ECM on page 4. [ See Controller Displays as Provided by the Engine ECM on page 4 for display availability. Modbusr is a registered trademark of Schneider Electric. G6-46 12/15o Page 5 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Decision-Makerr 550 Controller Available Options Communication and PC Software Available Options Refer to spec sheet G6-76, Monitor III Software for additional communication and PC software information including Modbusr communication. - Local Single Connection. A PC is connected directly to the device communication module with an RS-232 cable for applications where the PC is within 15 m (50 ft.) of the device or RS-485 cable for applications where the PC is up to 1220 m (4000 ft.) from the device. Other Available Options - Common Failure Relay remotely signals auxiliary fault, emergency stop, high engine temperature, low oil pressure, overcrank, and overspeed via one single-pole, double-throw relay with 10-amp contacts at 120 VAC or 28 VDC maximum. - Run Relay provides a three-pole, double-throw relay with 10-amp contacts at 120 VAC or 28 VDC maximum for indicating that the generator set is running. - Controller Cable enables remote mounting of the controller with distances of up to 12 m (40 ft.) from the generator set. - Local Area Network (LAN). A PC is connected directly to the device’s local area network. A LAN is a system of connecting more than one device to a single PC. - Remote Network (Ethernet): A PC with a NIC card uses an Ethernet connection to access a remotely located converter (Modbusr/Ethernet) serving a controller. Refer to G6-79 for system details. - Remote Network (Modem): A PC uses a modem to connect to a remotely located device modem serving a controller. Monitoring software (Monitor III) runs on the PC to view system operation. - Monitor III Software for Monitoring and Control (Windowsr-based user interface) - Converter, Modbusr/Ethernet. Supports a power system using a controller accessed via the Ethernet. Converter is supplied with an IP address by the site administrator. Refer to G6-79 for converter details. - RS-232 to RS-485 Port Converters - Controller Connection Kit provides a cable connecting the controller output terminals to a terminal strip in the junction box. - Dry Contact Kit interfaces between the controller signals and customer-supplied accessories providing contact closure to activate warning devices such as lamps or horns. Kits are available with either one or ten single-pole, double-throw (form-C) relays with 10-amp contacts at 120 VAC or 28 VDC maximum. - Float/Equalize Battery Charger with Alarm Feature signals controller of battery charger fault. - Prealarm Kit for NFPA 110 (gas fuel models only) warns the operator of low fuel pressure. Select the kit based on LP vapor or natural gas, combination dual fuel, or LP liquid withdrawal. - Prime Power Switch prevents battery drain during generator set non-operation periods and when the generator set battery cannot be maintained by an AC battery charger. - Remote Audiovisual Alarm Panel warns the operator of fault shutdowns and warning conditions. Kit includes common fault lamp and horn with silence switch. - Remote Emergency Stop Panel immediately shuts the generator set down from a remote station. - Remote Serial Annunciator (RSA) Panel enables the operator to monitor the status of the generator set from a remote location, which may be required for NFPA 99 and NFPA 110 installations. Uses Modbusr protocol, an industry standard. or Personal computer Device modem External PC modem RS-232 to RS-485 port converter Modbusr is a registered trademark of Schneider Electric. Windowsr is a registered trademark of Microsoft Corporation. Telephone lines DISTRIBUTED BY: Generator Set with the Decision-Makerr 550 controller Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator set distributor for availability. 2003, 2005, 2006, 2007, 2008, 2011, 2012, 2013, 2015 by Kohler Co., All rights reserved. G6-46 12/15o Page 6 Industrial Generator Set Accessories Float/Equalize Battery Charger Standard Features D Kohler automatic battery chargers feature two charging modes to keep lead-acid and nickelcadmium batteries fully charged without overcharging. The battery charger automatic float-to-equalize operation maintains battery voltage with no manual intervention. D Temperature compensation feature prevents overcharging or undercharging battery at high/low ambient temperatures. EXPLOSION. Battery gases can cause explosion and severe injury or death. D Current-limiting circuitry prevents battery charger from overload at low battery voltage and during a short circuit. The ten amp DC current limit allows the battery charger to remain connected to the battery during engine cranking. Remove AC power from charger before connecting or disconnecting to battery terminals. D Battery charger complies with NFPA 110 code requirements when equipped with optional alarm circuit board. Alarm board features low battery voltage, high battery voltage, and battery charger malfunction alarm contacts. Specifications Loose Battery Charger Kit No. Output Number of Cells NFPA 110 Alarm Outputs Voltage Amps Lead Acid Ni-Cd Installed Battery Charger Kit Nos. PAD-292862 PAD-292863 PAD-292864, GM78809-KP2 — GM39705-KA1, GM42342-KA1 GM28562-KA2, -KA4, -KA6, -KA8, GM51537-KA2, GM78809-KA2, GM87550-KA1 PAD-292865, GM78809-KP1 GM28562-KA1, -KA3, -KA5, -KA7, GM51537-KA1, GM78809-KA1, GM87550-KA2 AC Input Voltage, Frequency DC Voltage Regulation Weight (battery charger without mounting brackets) Dimensions, L x D x H No Yes 12 6 9 12 18 10 No 24 Yes 120/240 VAC, 50/60 Hz ±1% 11.8 kg (26 lb.) 271 x 143 x 422 mm (10.67 x 5.63 x 16.63 in.) (battery charger without mounting brackets) Note: Installed battery charger kits are available on selected generator set models. See your authorized distributor for availability. G6-15 7/13m Automatic Float to Equalize Battery Voltage Charging Current When the battery loses its charge, the battery charger operates in the High Rate Constant Current Mode until the battery voltage rises to the preset equalize level. At the preset equalize level, the battery charger switches to the constant voltage Equalize Mode until the current required to maintain this voltage drops to 50% of the battery charger’s high rate current. Equalize Voltage Float Voltage 50% of High Rate 100% Output Current Float Current The battery charger then switches to the lower constant voltage Float Mode when the battery nears full charge. The battery charger continues to operate in this mode until AC input power disconnects or the current required to maintain the battery at the float voltage setting exceeds 6 amps. Time High Rate Constant Current Mode Equalize Mode Float Mode Figure 1 Temperature Compensation The battery charger compensates for battery temperature using a negative temperature coefficient. The battery charger provides temperature compensation of --2 mv/°C per cell over the ambient temperature range of --40°C up to 60°C. The temperature compensation automatically adjusts the float and equalize voltage settings to prevent the battery from overcharging at high ambient temperatures and undercharging at low ambient temperatures. 60 ° 40 20 0 -20 92 94 96 98 100 102 104 % of Nominal Charging Voltage Figure 2 G6-15 7/13m 106 Standard Features D Ammeter and voltmeter indicate battery charging rate with 5% full-scale accuracy. POWER ON lamp indicates battery charger is operating. D Reconnection blocks allow operation at 120 or 240 volts AC, single phase, 50 or 60 hertz. D Battery charger circuitry protected from AC line and DC load voltage spikes and transients. D AC input and DC output fuses prevent battery charger damage from abnormal overload and short-circuit conditions. D Terminal block for remote battery sensing leads. D Operational temperature range is from --40°C (--40°F) to 60°C (140°F). Battery charger float and equalize voltage automatically adjust throughout the temperature range. D Reverse polarity protection circuitry prevents battery charger from energizing if improperly connected. D Internal terminal blocks for AC input and DC output/ sensing lead connections. D Automatic float-to-equalize operation with individual potentiometer adjustments. Charge up to 12 lead-acid or 18 nickel-cadmium battery cells. D No adjustments are necessary for lead-acid or nickel-cadmium batteries. D Oversized transformer and SCR heatsink allow constant current charging at 10 amps up to the equalize voltage setting for fastest battery charging. D DC voltage regulation of ±1% from no load to full load and AC input line voltage variations of ±10%. D UL-1012 listed/CSA certified. D Wall-mount, slotted enclosure with knockouts for customer conduit installation. G6-15 7/13m Note: The battery charger will discharge the engine starting battery(ies) when the battery charger is connected to the battery(ies) and is not connected to an AC power supply. To prevent engine starting battery(ies) discharge, install battery charger relay kit GM39659. KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com EXPLOSION. Battery gases can cause explosion and severe injury or death. Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Remove AC power from charger before connecting or disconnecting to battery terminals. ADV-5971--A DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator set distributor for availability. © 1993, 1994, 1995, 1999, 2003, 2005, 2011, 2012, 2013 by Kohler Co. All rights reserved. G6-15 7/13m Model: 400REOZJB 208--600 V Tier 3 EPA-Certified for Stationary Emergency Applications Ratings Range Standby: kW kVA Diesel Standard Features D Kohler Co. provides one-source responsibility for the generating system and accessories. D The generator set and its components are prototype-tested, factory-built, and production-tested. D The 60 Hz generator set offers a UL 2200 listing. D The generator set accepts rated load in one step. D The 60 Hz emergency generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. D A one-year limited warranty covers all generator set systems and components. Two- and five-year extended limited warranties are also available. D Alternator features: d The pilot-excited, permanent magnet (PM) alternator provides superior short-circuit capability. d The brushless, rotating-field alternator has broadrange reconnectability. D Other features: d Kohler designed controllers for guaranteed system integration and remote communication. See Controllers on page 3. d The low coolant level shutdown prevents overheating (standard on radiator models only). d Integral vibration isolation eliminates the need for under-unit vibration spring isolators. d An electronic, isochronous governor delivers precise frequency regulation. d Multiple circuit breaker configurations. 60 Hz 315--410 394--513 Generator Set Ratings Alternator 4M4021 5M4027 5M4028 4M4266 5M4272 Voltage Ph Hz 150_C Rise Standby Rating kW/kVA Amps 120/208 127/220 139/240 220/380 240/416 277/480 120/208 127/220 139/240 220/380 240/416 277/480 120/208 127/220 139/240 220/380 240/416 277/480 347/600 347/600 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 60 400/500 410/513 410/513 315/394 400/500 410/513 410/513 410/513 410/513 405/506 410/513 410/513 410/513 410/513 410/513 410/513 410/513 410/513 410/513 410/513 1388 1345 1233 598 694 616 1423 1345 1233 769 711 616 1423 1345 1233 779 711 616 493 493 130_C Rise Standby Rating kW/kVA Amps 380/475 390/488 400/500 315/394 380/475 405/506 410/513 410/513 410/513 405/506 410/513 410/513 410/513 410/513 410/513 410/513 410/513 410/513 400/500 410/513 1318 1279 1203 598 659 609 1423 1345 1233 769 711 616 1423 1345 1233 779 711 616 481 493 RATINGS: All three-phase units are rated at 0.8 power factor. Standby Ratings: The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-8528-1 and ISO-3046-1. Obtain technical information bulletin (TIB-101) for ratings guidelines, complete ratings definitions, and site condition derates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. G5-403 (400REOZJB) 7/15c Alternator Specifications D NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting. Specifications Alternator Type Exciter type 4-Pole, Rotating-Field Brushless, PermanentMagnet, Pilot Exciter Leads: quantity, type 12, Reconnectable 4, 600 V Solid State, Volts/Hz NEMA MG1 Class H, Synthetic, Nonhygroscopic D Sustained short-circuit current enabling downstream circuit breakers to trip without collapsing the alternator field. Temperature rise Bearing: quantity, type Coupling Amortisseur windings Rotor balancing Voltage regulation, no-load to full-load One-step load acceptance Unbalanced load capability 130_C, 150_C Standby 1, Sealed Flexible Disc Full 125% Controller Dependent 100% of Rating 100% of Rated Standby Current D Brushless alternator with brushless pilot exciter for excellent load response. Peak motor starting kVA: 480 V 4M4021 (12 lead) 480 V 5M4027 (12 lead) 480 V 5M4028 (12 lead) 600 V 4M4266 (4 lead) 600 V 5M4272 (4 lead) (35% dip for voltages below) 1350 1550 1800 1300 1750 Voltage regulator Insulation: Material D Self-ventilated and dripproof construction. D Superior voltage waveform from a two-thirds pitch stator and skewed rotor. Application Data Engine Engine Electrical Engine Specifications Engine manufacturer Engine model Engine type Cylinder arrangement Displacement, L (cu. in.) Bore and stroke, mm (in.) Compression ratio Piston speed, m/min. (ft./min.) Main bearings: quantity, type Rated rpm Max. power at rated rpm, kWm (BHP) Crankshaft material Valve material Intake/Exhaust Governor: type, make/model Frequency regulation, no-load to full-load Frequency regulation, steady state Frequency Air cleaner type, all models Engine Electrical System John Deere 6135HFG84 4-Cycle, Turbocharged, Charge Air-Cooled 6, Inline 13.5 (824) 132 x 165 (5.2 x 6.5) 16.0:1 594 (1950) 7, Replaceable Insert 1800 460 (617) Forged Steel Nickel-Chromium Head Chromium-Silicone Stem JDEC Electronic L15 Isochronous 0.25% Fixed Dry Exhaust Exhaust System Exhaust manifold type Exhaust flow at rated kW, m3/min. (cfm) Exhaust temperature at rated kW, dry exhaust, _C (_F) D Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds. Battery charging alternator: Ground (negative/positive) Volts (DC) Ampere rating Starter motor rated voltage (DC) Battery, recommended cold cranking amps (CCA): Qty., CCA rating each Battery voltage (DC) Negative 24 60 24 Two, 950 12 Fuel Fuel System Fuel supply line, min. ID, mm (in.) Fuel return line, min. ID, mm (in.) Max. lift, fuel pump: type, m (ft.) Max. fuel flow, Lph (gph) Max. return line restriction, kPa (in. Hg) Fuel prime pump Fuel filter Secondary Primary Water Separator Recommended fuel 13 (0.50) 10 (0.38) Electronic 2.1 (6.8) 191.3 (50.5) 35 (10.3) Electronic 2 Microns @ 98% Efficiency 10 Microns Yes #2 Diesel Lubrication Dry 74 (2606) Lubricating System Maximum allowable back pressure, kPa (in. Hg) 527 (981) Min. 4 (1.2) Max. 7.5 (2.2) Engine exhaust outlet size, mm (in.) See ADV drawing Type Oil pan capacity, L (qt.) Oil pan capacity with filter, L (qt.) Oil filter: quantity, type Oil cooler G5-403 (400REOZJB) 7/15c Full Pressure 40.0 (42.3) 42.0 (44.4) 1, Cartridge Water-Cooled Application Data Controllers Cooling Radiator System Ambient temperature, _C (_F)* Engine jacket water capacity, L (gal.) Radiator system capacity, including engine, L (gal.) Engine jacket water flow, Lpm (gpm) Heat rejected to cooling water at rated kW, dry exhaust, kW (Btu/min.) Heat rejected to air charge cooler at rated kW, dry exhaust, kW (Btu/min.) Water pump type Fan diameter, including blades, mm (in.) Fan, kWm (HP) Max. restriction of cooling air, intake and discharge side of radiator, kPa (in. H2O) 50 (122) 18 (4.8) 67.2 (17.8) 400 (106) 208 (11839) 94 (5350) Centrifugal 965 (38) 18 (24) 0.125 (0.5) Decision-Makerr 3000 Controller Provides advanced control, system monitoring, and system diagnostics for optimum performance and compatibility. D Digital display and menu control provide easy local data access D Measurements are selectable in metric or English units D Remote communication thru a PC via network or serial configuration D Controller supports Modbusr protocol D Integrated hybrid voltage regulator with 0.5% regulation D Built-in alternator thermal overload protection D NFPA 110 Level 1 capability Refer to G6-100 for additional controller features and accessories. * Enclosure with internal silencer reduces ambient temperature capability by 5_C (9_F). Operation Requirements Air Requirements Radiator-cooled cooling air, m3/min. (scfm)[ Cooling air required for generator set when equipped with city water cooling or remote radiator, based on 14_C (25_F) rise, m3/min. (cfm)[ Combustion air, m3/min. (cfm) Heat rejected to ambient air: Engine, kW (Btu/min.) Alternator, kW (Btu/min.) 651 (23000) 297 (10500) 28 (996) 43 (2448) 40 (2277) [ Air density = 1.20 kg/m3 (0.075 lbm/ft3) Decision-Makerr 550 Controller Provides advanced control, system monitoring, and system diagnostics with remote monitoring capabilities. D Digital display and keypad provide easy local data access D Measurements are selectable in metric or English units D Remote communication thru a PC via network or modem configuration D Controller supports Modbusr protocol D Integrated voltage regulator with 0.25% regulation D Built-in alternator thermal overload protection D NFPA 110 Level 1 capability Refer to G6-46 for additional controller features and accessories. Fuel Consumption Diesel, Lph (gph) at % load 100% 75% 50% 25% Standby Rating 116.9 90.9 63.8 34.2 (30.9) (24.0) (16.8) (9.0) Decision-Makerr 6000 Paralleling Controller Provides advanced control, system monitoring, and system diagnostics with remote monitoring capabilities for paralleling multiple generator sets. D Paralleling capability with first-on logic, synchronizer, kW and kVAR load sharing, and protective relays D Digital display and keypad provide easy local data access D Measurements are selectable in metric or English units D Remote communication thru a PC via network or modem configuration D Controller supports Modbusr protocol D Integrated voltage regulator with 0.25% regulation D Built-in alternator thermal overload protection D NFPA 110 Level 1 capability Refer to G6-107 for additional controller features and accessories. Modbusr is a registered trademark of Schneider Electric. G5-403 (400REOZJB) 7/15c Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Standard Features Paralleling System - Manual Speed Adjust - Voltage Sensing D Alternator Protection D Battery Rack and Cables D Customer Connection (standard with Decision-Makerr 6000 controller only) D Local Emergency Stop Switch D Oil Drain Extension D Operation and Installation Literature Available Options - Approvals and Listings California OSHPD Pre-Approval CSA Approval IBC Seismic Certification UL 2200 Listing Enclosed Unit - Sound Enclosure Level 1 and Subbase Fuel Tank Packages - Sound Enclosure Level 2 and Subbase Fuel Tank Packages - Weather Enclosure and Subbase Fuel Tank Packages - Miscellaneous Air Cleaner, Heavy Duty Air Cleaner Restriction Indicator Crankcase Emissions Canister Engine Fluids Added Rated Power Factor Testing - Literature General Maintenance NFPA 110 Overhaul Production Warranty - 2-Year Basic Limited - 5-Year Basic Limited - 5-Year Comprehensive Limited Open Unit - Exhaust Silencer, Critical (kit: PA-354880) - Flexible Exhaust Connector, Stainless Steel Other Options - Fuel System - Flexible Fuel Lines (Select rubber or stainless steel) Controller - Common Failure Relay (Decision-Makerr 550 and 6000 controllers only) _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________________ _______________________________________________ - Communication Products and PC Software - Customer Connection (Decision-Makerr 550 controller only) Dimensions and Weights - Decision-Makerr Paralleling System (DPS) (Decision-Makerr 6000 controller only) Overall Size, L x W x H, max., mm (in.): - Dry Contact (isolated alarm) (Decision-Makerr 550 and 6000 controllers only) Weight (radiator model), wet, max., kg (lb.): 3630 x 1425 x 1993 (142.9 x 56.1 x 78.5) 3883 (8560) - Input/Output Module (Decision-Makerr 3000 controller only) - Remote Audiovisual Alarm Panel (Decision-Makerr 550 controller only) - Remote Emergency Stop - Remote Serial Annunciator Panel - Run Relay - H Cooling System Block Heater, 2500 W, 90--120 V, 1 Ph Block Heater, 2500 W, 190--208 V, 1 Ph Block Heater, 2500 W, 210--240 V, 1 Ph Block Heater, 2500 W, 380--480 V, 1 Ph Recommended for ambient temperatures below 0C (32F) W NOTE: This drawing is provided for reference only and should not be used for planning installation. Contact your local distributor for more detailed information. - Radiator Duct Flange - L Electrical System Alternator Strip Heater Battery Battery Charger, Equalize/Float Type Battery Heater Line Circuit Breaker (NEMA type 1 enclosure) Line Circuit Breaker with Shunt Trip (NEMA type 1 enclosure) DISTRIBUTED BY: E 2012, 2013, 2014, 2015 by Kohler Co. All rights reserved. G5-403 (400REOZJB) 7/15c TIB-102 TECHNICAL INFORMATION BULLETIN Alternator Data Sheet Alternator Model: (8--22--11) 5M4027 * Voltage refers to wye (star) connection, unless otherwise specified. TIB-102 5M4027 60 Hz 2/15w 1 Alternator Model: TYPICAL DYNAMIC CHARACTERISTICS 5M4027 Voltage refers to wye (star) connection, unless otherwise specified. 2 5M4027 60 Hz 2/15w TIB-102 5M4027, 60 Hz, Low Wye or Delta Connection SHORT CIRCUIT DECREMENT CURVE Full Load Current: 1788 Amps Steady State S.C. Current: 5364 Amps Max. 3 ph. Symm. S.C. Current: 9770 Amps 5M4027, 60 Hz, High Wye Connection SHORT CIRCUIT DECREMENT CURVE Full Load Current: 775 Amps Steady State S.C. Current: 2325 Amps Max. 3 ph. Symm. S.C. Current: 5657 Amps NOTE: Symmetrical component values are shown, maximum asymmetrical values are 1.732 times the symmetrical values. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. 2015 by Kohler Co. All rights reserved. TIB-102 5M4027 60 Hz 2/15w 3 Model KEP Automatic Transfer Switches Service Entrance Rated Transfer Switch Standard Features Enclosed Contact Power Switching Units D Service entrance automatic transfer switches incorporate an isolating mechanism and overcurrent protection on the utility supply, eliminating the need to have a separate, upstream utility source circuit breaker/disconnect switch. D UL 1008 listed, file #58962 D IBC seismic certification available D Fully enclosed silver alloy contacts provide high withstand rating. D 3-cycle short circuit current withstand-tested D Completely separate utility and generator set power switching units provide redundancy (no common parts) and are easy to service. D Utility disconnect power switching units have overcurrent protection; generator disconnect is available with or without overcurrent protection: d Molded case circuit breakers (MCCB) include thermalmagnetic or electronic trip overcurrent protection (80% rated) d Molded case switches (MCSW) do not include overcurrent protection (100% rated) (available on generator disconnect only) d Insulated case circuit breakers (ICCB) include electronic trip overcurrent protection (100% rated). d Insulated case switches (ICSW) do not include overcurrent protection (100% rated) (available on generator disconnect only) Controller D Decision-Makerr MPAC 1500 Ratings Power Switching Device Molded case (MCCB) Insulated Case (ICCB) Current Voltage, Frequency 200 208--240 VAC, 60 Hz 100--1200 208--480 VAC, 60 Hz 800--4000 208--480 VAC, 60 Hz D Inherent stored-energy design prevents damage if manually switched while in service. D Heavy duty brushless gear motor and operating mechanism provide mechanical interlocking and extreme long life with minimal maintenance. D Safe manual operation permits easy operation even under adverse conditions. D All mechanical and control devices are visible and readily accessible. D NEMA 1, 3R, 4X and 12 enclosures available D Padlockable service disconnect control switch D Status indicators D Two-position control circuit isolation switch disconnects utility power to the transfer switch controller. Service Disconnect Switch D Two-position switch with padlockable cover disconnects the normal source and inhibits transfer during maintenance or service. D Controller display shows SERVICE DISCONNECT. D Lamp illuminates to indicate that the switch is in the DISCONNECT position. D Further transfer is inhibited after transfer to Emergency. G11-133 (Model KEP Service Entrance Rated Transfer Switch) 3/14 Page 1 Automatic Transfer Switch Controller The Decision-Makerr MPAC 1500 Automatic Transfer Switch Controller is used on service entrance transfer switch models. Decision-Makerr MPAC 1500 Controller Codes and Standards The ATS meets or exceeds the requirements of the following specifications: D EN61000-4-4 Fast Transient Immunity Severity Level 4 D EN61000-4-5 Surge Immunity Class 4 (voltage sensing and programmable inputs only) D IEC Specifications for EMI/EMC Immunity: d CISPR 11, Radiated Emissions d IEC 1000-4-2, Electrostatic Discharge d IEC 1000-4-3, Radiated Electromagnetic Fields d IEC 1000-4-4, Electrical Fast Transients (Bursts) d IEC 1000-4-5, Surge Voltage d IEC 1000-4-6, Conducted RF Disturbances d IEC 1000-4-8, Magnetic Fields D LCD display, 4 lines x 20 characters, backlit D Complete programming and viewing capability at the door using the keypad and LCD display D LED indicators: Source available, transfer switch position, service required (fault), and “not in auto” D Modbus communication is standard D Programmable voltage and frequency pickup and dropout settings D Programmable time delays D Programmable generator exerciser D Time-based load control D Current-based load control (current sensing kit required) D Two programmable inputs and two programmable outputs D Up to four I/O extension modules available D RS-485 communication standard D Ethernet communication standard d IEC 1000-4-11, Voltage Dips and Interruptions D IEC 60947-6-1, Low Voltage Switchgear and Control Gear; Multifunction Equipment; Automatic Transfer Switching Equipment D IEEE Standard 446, IEEE Recommended Practice for Emergency and Standby Power Systems for Commercial and Industrial Applications D IEEE 472 (ANSI C37.90A) Ring Wave Test D NEMA Standard ICS 10--2005, Electromechanical AC Transfer Switch Equipment D NFPA 70, National Electrical Code D NFPA 99, Essential Electrical Systems for Health Care Facilities D NFPA 110, Emergency and Standby Power Systems D Underwriters Laboratories UL 1008, Standard for Automatic Transfer Switches for Use in Emergency Standby Systems file #58962 D Three-source system D Prime power For more information about Decision-Makerr MPAC 1500 features and functions, see specification sheet G11--128. G11-133 (Model KEP Service Entrance Rated Transfer Switch) 3/14 Page 2 Application Data Ratings Environmental Specifications Interrupting Capacity Current Rating With Integral Overcurrent Protection * Operating Temperature --15C to 50C (5F to 122F) Storage Temperature --20C to 70C (--4F to 158F) Humidity 95% noncondensing Auxiliary Position-Indicating Contacts MCCB Models Use programmable digital outputs ICCB Models 3 Normal, 2 Emergency Rated 2.5 A @ 24/48 VDC, 6 A @ 480VAC Typical Single-Line Diagram CUSTOMER LOAD SERVICE ENTRANCE AUTOMATIC TRANSFER SWITCH 3-POLE MODEL SHOWN GCB GENERATOR POWER SWITCHING DEVICE (NON-AUTO) MECHANICAL INTERLOCK UCB UTILITY POWER SWITCHING DEVICE W/TRIP UNIT N N UTILITY SUPPLY REMOVABLE NEUTRAL GROUND BOND CONDUCTOR GENERATOR CIRCUIT BREAKER N (No upstream circuit breaker protection required) Power Switching Device Switch Rating, Amps Voltage, Max. Amps RMS @ 240 V @ 480 V 100 600 65,000 25,000 150 600 200 240 65,000 NA 250 600 65,000 35,000 Molded 400 case 600 800 600 65,000 50,000 1000 1200 800 1000 1200 1600 Insulated 600 100,000 100,000 case 2000 2500 3000 4000 * With molded case/insulated case switching devices equipped with integral overcurrent protection. STANDBY GENERATOR SET Cable Sizes Cable Sizes, Al/Cu Wire Model Amps Circuit Breaker (per Phase) 100 (1) #14 - 1/0 AWG 150 (2) #2 - 4/0 AWG 200 KEP, MCCB (3) #14 - 1/0 AWG (3) #6 - 350 KCMIL (2) 2/0 - 500 KCMIL (6) 2/0 - 500 KCMIL 800 (3) 2/0 - 500 KCMIL (9) 2/0 - 500 KCMIL 1000 1200 (4) 4/0 - 500 KCMIL (12) 4/0 - 500 KCMIL 250 400 Ground (3) #14 - 2/0 AWG (1) #6 - 350 KCMIL 600 KEP, ICCB Neutral (3) #6 - 350 KCMIL (3) #4 - 600 KCMIL 800 (3) 3/0 - 750 KCMIL (9) 3/0 - 750 KCMIL 1000 (4) 3/0 - 750 KCMIL (12) 3/0 - 750 KCMIL 1200 (4) 3/0 - 750 KCMIL (12) 3/0 - 750 KCMIL 1600 (5) 3/0 - 750 KCMIL (15) 3/0 - 750 KCMIL 2000 (6) 3/0 - 750 KCMIL (18) 3/0 - 750 KCMIL 2500 (8) 3/0 - 750 KCMIL (24) 3/0 - 750 KCMIL 3000 (9) 3/0 - 750 KCMIL (27) 3/0 - 750 KCMIL (3) #6 - 250 KCMIL 4000 (12) 3/0 - 750 KCMIL (36) 3/0 - 750 KCMIL (3) #6 - 250 KCMIL G11-133 (Model KEP Service Entrance Rated Transfer Switch) 3/14 Page 3 (3) #6 - 250 KCMIL (3) #6 - 250 KCMIL (3) #6 - 250 KCMIL Weights and Dimensions Weights and dimensions are shown for NEMA type 1 enclosures. Consult the factory for other enclosure types. Weights and dimensions are shown for reference only. Refer to the transfer switch dimension drawing for planning and installation. Molded Case Circuit Breaker (MCCB) Models Dimensions, mm (in.) Model KEP, MCCB Weight, kg (lb.) Amps Poles Height Width Depth 2P 3P 4P 100-150 2,3,4 914 (36.0) 725 (28.5) 462 (18.2) 68 (150) 68 (150) 68 (150) 200 2,3 914 (36.0) 725 (28.5) 462 (18.2) 68 (150) 68 (150) N/A 250 2,3,4 914 (36.0) 725 (28.5) 462 (18.2) 81 (178) 81 (178) 81 (178) 400 2,3,4 1231 (48.4) 995 (39.2) 486 (19.1) 195 (430) 195 (430) 195 (430) 600-800 2,3,4 1231 (48.4) 995 (39.2) 486 (19.1) 200 (441) 200 (441) 200 (441) 1000-1200 3,4 2024 (79.7) 875 (34.4) 515 (20.3) N/A 270 (595) 270 (595) Insulated Case Circuit Breaker (ICCB) Models Dimensions, mm (in.) Model Amps 800 1000-1200 1600 KEP, ICCB 2000 2500 3000 4000 Poles Height Width Depth Weight, kg (lb.) 3 2324 (91.5) 914 (36.0) 1219 (48.0) 544 (1200) 4 2324 (91.5) 914 (36.0) 1219 (48.0) 635 (1400) 3 2324 (91.5) 914 (36.0) 1219 (48.0) 553 ( 1220) 4 2324 (91.5) 914 (36.0) 1219 (48.0) 644 (1420) 3 2324 (91.5) 914 (36.0) 1372 (54.0) 598 (1320) 4 2324 (91.5) 914 (36.0) 1372 (54.0) 625 (1380) 3 2324 (91.5) 914 (36.0) 1372 (54.0) 607(1340) 4 2324 (91.5) 914 (36.0) 1372 (54.0) 644 (1420) 3 2324 (91.5) 914 (36.0) 1524 (60.0) 625 (1380) 4 2324 (91.5) 1067 (42.0) 1524 (60.0) 662 (1460) 3 2324 (91.5) 914 (36.0) 1524 (60.0) 644 (1420) 4 2324 (91.5) 1067 (42.0) 1524 (60.0) 680 (1500) 3 2324 (91.5) 1372 (42.0) 1524 (60.0) 907 (2000) 4 2324 (91.5) 1372 (42.0) 1524 (60.0) 1270 (2800) G11-133 (Model KEP Service Entrance Rated Transfer Switch) 3/14 Page 4 Accessories Accessories are available either factory-installed or as loose kits, unless otherwise noted. - Digital Meter D Measure and display voltage, current, frequency, and power for both sources: D Programmable visual alarms for high voltage, low voltage, and high current D Three digital outputs D Serial port for optional network connections D Password-protected programming menus D Joystick operation D Factory-installed - Extended Warranties D 2-year basic D 5-year basic D 5-year comprehensive D 10-year major components - Heater, Anti-Condensation D Hygrostat-controlled 120 VAC strip heater (customer-supplied voltage source required) D 100 or 250 watts (sized for enclosure) D Protective 15 Amp circuit breaker - Literature Kits D Production literature kit (one set of literature is included with each transfer switch) D Overhaul literature kit - Load Shed Kit D Forced transfer from Emergency to OFF for programmed-transition models D Customer-supplied signal (contact closure) is required for the forced transfer to OFF function D Factory-installed - RSA III Remote Serial Annunciator D Monitors the generator set D Monitors Normal and Emergency source status and connection D Monitors ATS common alarm D Allows remote testing of the ATS D For more information, see specification sheet G6--139. - Seismic Certification D Certification depends on application and geographic location. Contact your distributor for details. D Available for the transfer switches and enclosures shown below: ATS Type and Size Enclosure, NEMA Type: Type Amps 1 3R MCCB 100--600 MCCB 100--1200 D D ICCB 800--4000 D D 4X 12 D D - Surge Protection Device (SPD) D SPD available for the normal source supply D Surge protection reduces transient voltages to harmless levels D Protection modes: L-L / L-N / L-G / N-G D Replaceable phase and neutral cartridges for service D Frequency: 50--60 Hz D Operating Temperature Range: --40 to 176_F (--40 to 80_C) D Remote contacts for customer-supplied status indicators: Contacts: 1 NO, 1 NC Min Load: 12VDC / 10 mA Max. Load: 250 VAC / 1 A Wire Size (max.): 16AWG D Fuse protection: 30 amps / 600 V D UL 1449, 3rd Edition for Type 2 applications D IEC 61-643-1, 2nd Edition T2/11 D See additional specifications below Additional Controller Accessories See the controller specification sheet for more information. - Accessory Modules D Alarm Module D External Battery Supply Module D Input/Output Module D High-Power Input/Output Module - Current Sensing Kit - Line-to-Neutral Voltage Monitoring - Padlockable User Interface Cover - Supervised Transfer Control Switch SPD Specifications 240 / 120 Max. Discharge Current (kA) 40 Phase Split Poles 3 208 / 120 40 Wye 480 / 277 40 240 / 120 600 / 347 Nominal Voltage (V ±15%) at 3kAmps at 10kAmp Short Circuit Withstand Current (kA) 0.6 / 1.2 / 0.7 0.6 / 0.4 / 0.6 0.8 / 0.7 / 0.8 200 Maximum Continuous Operating Voltage (VAC) 175 / 350 4 0.6 / 1.2 / 0.7 0.6 / 0.4 / 0.6 0.8 / 0.7 / 0.8 200 175 / 350 Wye 4 1.0 / 1.2 / 1.1 1.0 / 0.4 / 1.0 1.2 / 0.7 / 1.2 200 320 / 460 40 HLD 4 1.0 / 1.2 / 1.1 1.0 / 0.4 / 1.0 1.2 / 0.7 / 1.2 200 320 / 460 40 Wye 4 1.3 / 1.2 / 1.4 1.3 / 0.4 / 1.3 1.5 / 0.7 / 1.5 200 440 / 880 UL VPR 3rd Ed (L-N/N-G/L-G) (kV) Limiting Voltage, (L-N/N-G/L-G) (kV) G11-133 (Model KEP Service Entrance Rated Transfer Switch) 3/14 Page 5 KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Model Designation Model Mechanism Transition Controls Voltage Poles Enclosure Current Rating Connection Utility Sw. Gen Sw. Record the transfer switch model designation in the boxes. The transfer switch model designation defines characteristics and ratings as explained below. Sample Model Designation: KEP-DMTA-0400S-NK Model Current, Amps K: 0100 0600 2000 0150 0800 2500 Mechanism 0200 1000 3000 E: 0250 1200 4000 0400 1600 Kohler Service Entrance Rated Transition P: Programmed Connections S: Standard Controller D: Decision-Makerr MPAC 1500, Automatic Voltage/Frequency Utility Switching Device M: MCCB w/thermal magnetic trip 100--200 A N: MCCB w/electronic trip 250--800 A C: 208 Volts / 60 Hz M: 480 Volts / 60 Hz P: MCCB w/electronic trip and GF 1000--1200 A F: 240 Volts / 60 Hz R: 220 Volts / 60 Hz R: ICCB w/electronic trip 800 A K: 440 Volts / 60 Hz T: ICCB w/electronic trip and GF 1000--4000 A Number of Poles/Wires Generator Switching Device N: 2 Poles / 3 Wires, Solid Neutral K: MCSW 100--1200 A T: 3 Poles / 4 Wires, Solid Neutral M: MCCB w/thermal magnetic trip 100--200 A V: 4 Poles / 4 Wires, Switched Neutral N: MCCB w/electronic trip 250--1200 A Q: ICSW 800--4000 A R: ICCB w/electronic trip 800--4000 A Enclosure A: NEMA 1 C: NEMA 3R B: NEMA 12 F: NEMA 4X Note: Some selections are not available for every model. Contact your Kohler distributor for availability. DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator distributor for availability. 2014 by Kohler Co. All rights reserved. G11-133 (Model KEP Service Entrance Rated Transfer Switch) 3/14 Page 6 Power System Accessories Monitor III Software Applicable Controllers Monitoring and Control Software Monitor III software provides monitoring and control of Kohlerr generator sets and transfer switches equipped with the following controllers: Decision-Makerr 6000 Decision-Makerr 6000 generator set controller Decision-Makerr 3000 generator set controller Decision-Makerr 550 generator set controller Decision-Makerr 340 generator set controller Decision-Makerr 3+ generator set controller Decision-Makerr 3000 MPACt 1500 automatic transfer switch controller MPACt 1000 automatic transfer switch controller M340 and M340+ automatic transfer switch controllers PM340 Power Monitor Standard Software Features and Functions D Monitor and control the power system generator sets and transfer switches from a personal computer using a single software package D Monitor and control systems through a Windowsr-based graphical user interface D View the status of all devices on one site overview screen D Password-protected data access: Guest, User, and Supervisor D Monitor and control systems over a local area network, remotely via a modem connection, or through an Ethernet connection D Connect up to 247 controller devices on a local area network D Monitor data from multiple devices on the same local area network simultaneously D Start or stop the generator set from a PC D Read and adjust trip points, time delays, and system parameter settings D Assign inputs and outputs D View ECM data for ECM-equipped engines Decision-Makerr 550 Decision-Makerr 3+ Decision-Makerr 340 D View system run time history D View up to 100 recent events including engine starts, faults, shutdowns, and warnings D Device data windows automatically update D Software kits include hardware for either local or remote communications MPACt 1500 MPACt 1000 Windowsr is a registered trademark of Microsoft Corporation. M340+ ATS Controller and PM340 Power Monitor are not illustrated. G6-76 (Monitor III Software) 6/11b Page 1 Monitoring and Control Software Use Monitor III software to create screens containing data windows that display system information, controller settings, and operating status for connected generator sets, transfer switches, and power monitors. For more information, see TP-6347, Monitor III Software Operation and Installation Manual. Minimum System Requirements D 133 MHz or higher Intelr Pentiumr-compatible CPU D 32 MB RAM D CD-ROM drive and 75 MB hard drive space available for installation D 800 x 600 or better color monitor (1024 x 768 recommended) D Easily select, create, arrange, or delete data windows. D Create data windows for multiple devices in a network. D Create and save multiple screen configurations. D Display screens show system status and settings. D COM port numbered between 1 and 255, capable of baud rate 9600 or 19200 (for direct local connection) D Password-protected setup windows allow remote operation and adjustment. D PC network interface card (NIC) (for applications using ethernet connections only) Kohler publishes Modbusr data register maps for its products. Modbus protocol manual TP-6113 is available through Kohler distributors. Modbusr is registered trademark of Schneider Electric. D Microsoftr Windowsr 2000, Windowsr XP, Windows Vistar, or Windowsr 7 operating system D Adober Acrobatr or Adober Readerr (to display the Help file) Intelr and Pentiumr are registered trademarks of Intel Corporation. Microsoftr, Windowsr, and Windows Vistar are registered trademarks of Microsoft Corporation. Adober Acrobatr and Adober Readerr are registered trademarks of Adobe Systems Incorporated. G6-76 (Monitor III Software) 6/11b Page 2 Decision-Makerr 550 and Decision-Makerr 6000 Generator Set Controllers All of the following information is available through Decision-Makerr 550 and Decision-Makerr 6000 controller communications. Adjustments and manual operations are password-protected. Parameter Date and Time Date Time Synchronize with computer Electrical Information % of rated kW Current, L1, L2, L3 Frequency Voltage, line-line Voltage, line-neutral Total kVA, L1, L2, and L3 Total kVAR, L1, L2, and L3 Total kW, L1, L2, and L3 Total power factor, L1, L2, and L3 Engine Info Battery voltage (ECM) Coolant Level Coolant Pressure Coolant Temperature Engine speed (RPM) Fuel last run consumption Fuel pressure Fuel burn rate, liters/hr. or gal./hr. Fuel temperature Intake air filter diff. pressure Intake air temperature Oil pressure Oil level Oil temperature Oil crankcase pressure Event History (100 most recent events) Faults Warnings Shutdowns Input activation Output activiation Save history button Time and date of each event Generator Info Battery voltage, nominal Connection, wye or delta Rating, kW NFPA 110 defaults, enabled or disabled Phases, single or three Frequency, nominal Voltage, nominal Operating mode, standby or prime power View Adjust D D D D D D D D D D D D D D View Adjust D D D D D D D D D * Total and since last maintenance D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D Parameter Maintenance kW hours * Last maintenance date Last run start date Last run start time Loaded/unloaded run time * Number of starts * Operating days Run time * Last run time, loaded and unloaded D D D D D D D D D D Maintenance Operations Reset maintenance records button Reset faults button System Info Alternator part number Controller serial number Engine part number Final assembler’s clock number Final assembly date Generator set serial number Generator set model number Genset name (optional, user-defined) Load description (optional, user-defined) Location (optional, user-defined) Device ID Specification number Application code version (controller) Time Delays Crank on Crank pause Engine cooldown Engine start Load shed Maximum crank cycles Overvoltage Starting aid Undervoltage Trip Points High battery voltage load shed output Low battery voltage Overfrequency Overspeed Overvoltage Underfrequency Undervoltage G6-76 (Monitor III Software) 6/11b Page 3 D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D Decision-Makerr 550 and Decision-Makerr 6000 Controllers, continued Relay Driver Outputs (RDOs), System Events, and Common Alarms Assign up to 31 relay driver outputs (RDOs). Define any event as a common fault, except as noted. Parameter View Adjust Relay Driver Outputs (RDOs), System Events, and Common Alarms High shutdown enable/disable D D High warning enable/disable D D Low shutdown enable/disable D D Low warning enable/disable D D Assign/remove functions: D D AC sensing loss D D Air damper control D D Air damper indicator D D Air/fuel module (AFM) remote start D D Air temperature signal loss D D Alternator protection shutdown D D Analog inputs 1--7 D D Battery charger fault D D Breaker trip D D Critical overvoltage D D Defined common fault (not selectable as D D common fault) Delay engine cooldown D D Delay engine start D D Digital inputs 1--21 D D EEPROM write failure D D Emergency power system (EPS) D D supplying load Emergency stop D D Fuel valve relay D D Generator running D D Ground fault D D High air temperature shutdown D D High air temperature warning D D High battery voltage D D High coolant temperature shutdown D D High coolant temperature warning D D High oil temperature shutdown D D High oil temperature warning D D In synch D D Internal fault D D Load shed kW over D D Load shed overtemperature D D Load shed underfrequency D D Locked rotor D D Parameter Loss of ECM communications Loss of field shutdown Low battery voltage Low coolant level Low coolant temperature shutdown Low coolant temperature warning Low fuel Master switch error Master switch not in AUTO Master switch off Master switch open Block heater control (for future MDEC applications) Yellow alert (for future MDEC applications) Red alert (for future MDEC applications) NFPA 110 fault No coolant temperature signal No oil pressure signal Oil pressure shutdown Oil pressure warning Oil temperature signal loss Overcrank Overcurrent shutdown Overcurrent warning Overfrequency Overpower shutdown Overspeed Overvoltage Prelube relay Protective relay common (for switchgear) Reverse power shutdown (for switchgear) Software-controlled relay driver outputs (SCRDOs) 1--4 (on/off) Speed sensor fault Starting aid System ready Underfrequency Undervoltage Weak battery G6-76 (Monitor III Software) 6/11b Page 4 View D D D D D D D D D D D D Adjust D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D Decision-Makerr 550 and Decision-Makerr 6000 Controllers, continued Inputs Assign up to 7 analog inputs and 21 digital inputs. Parameter Digital Inputs (assign up to 21) Delay time Inhibit time Enable/disable Assign/remove functions: Warning Shutdowns, type A and B Voltage raise Voltage lower Variable PF (power factor) mode Remote shutdown Remote reset Air damper Low fuel (level or pressure) Field overvoltage Idle mode active (ECM only) Battleswitch Ground fault Battery charger fault High oil temperature (non-ECM) Low coolant level Low coolant temperature (not user-selectable) Enable synch (not user-selectable) AFM (air-fuel module) shutdown [ Knock shutdown [ Detonation warning [ Detonation shutdown [ Low fuel shutdown [ Breaker closed (not user-selectable) View Adjust D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D Parameter Analog Inputs (assign up to 7) High shutdown value High warning value Inhibit time Low shutdown value Low warning value Shutdown delay Shutdown enabled Warning delay Warning enabled Description (optional, user-defined) Battery voltage View Adjust D D D D D D D D D D D D D D D D D D D D D Remote Operation (password-protected) Manual Operation Generator set run time Set run time Start generator set Stop generator set Maintenance Operations Reset maintenance records button Reset faults button D D D D D D [ Waukesha engines only G6-76 (Monitor III Software) 6/11b Page 5 Control D D D D D D Decision-Makerr 3000 Generator Set Controller The following information for Decision-Makerr 3000 controllers can be monitored through Monitor III. Parameter Electrical Information Total kVA Total kW % of Rated kW Voltage L1-L2 Voltage L2-L3 Voltage L3-L1 Voltage L1-L0 Voltage L2-L0 Voltage L3-L0 Current L1, A Current L2, A Current L3, A Frequency, Hz Engine Information (Analog) Engine Speed, RPM Coolant Temperature, _C and _F Oil Pressure, PSI and kPa Battery Voltage, VDC ECM Battery Voltage, VDC View D D D D D D D D D D D D D D D D D D Parameter Generator Information Genset Rating Nominal Voltage Nominal Current Nominal Frequency Nominal Battery Voltage Phases Connection Alarm Silence Always Total Energy Delivered System Information Genset Model No. Genset Spec No. Genset Serial No. Alternator Part No. Engine Model No. Engine Part No. Engine Serial No. Software Version No. G6-76 (Monitor III Software) 6/11b Page 6 View D D D D D D D D D D D D D D D D D Decision-Makerr 340 Generator Set Controller All of the following information for Decision- Makert 340 generator set controllers can be monitored through Monitor III. Manual operations are password-protected. A Modbus/KBUS converter is required for this device. Parameter View Auxiliary inputs Delay time D Description D Inhibit time D Common faults (1--6) D Date/Time D Electrical Info D Current, L1, L2, and L3 D Frequency D Power level (percent of alternator kilowatt rating) D Power factor D Total kilowatts D Voltage, line-to-line for all phases D Voltage, line-to-neutral for all phases D Engine parameters Battery voltage D Coolant temperature D Engine speed D Oil pressure D History (since initial startup and since last maintenance record reset) Days of operation D Last run time (duration) D System startup date and time D Energy delivered, kilowatt hours D Last start date D Last start time D Number of starts D Run time loaded D Run time unloaded D Shutdown history, date and description (code) D Relay driver output assignments (1--10) D System information Controller serial number D Generator set name D Load description D Location D Model number D Generator set serial number D Specification number D Parameter System summary Generator set kilowatt rating Battery voltage (12 or 24), nominal Generator status (stopped/running/cranking) Master switch position Programming mode System status including current shutdown or warning System voltage (nominal) System frequency (nominal) Time delay settings Crank on Crank pause Engine cooldown Engine start Maximum number of crank cycles Overvoltage Undervoltage Starting aid Trip point settings Low battery voltage High battery voltage Overfrequency Underfrequency Overspeed Overvoltage Undervoltage View D D D D D D D D D D D D D D D D D D D D D D D Remote Operation (password-protected) Operation Reset faults Generator set run time Set run time (start/stop generator set) G6-76 (Monitor III Software) 6/11b Page 7 Control D D D Decision-Makerr 3+ Generator Set Controller with Communications All of the following information for Decision-Makert 3+ generator set controllers can be monitored through Monitor III. The Decision-Makert 3+ controller with communications (red main logic board) and the Modbusr communication board are required. Manual operations are password-protected. Parameter View Status (on/off indicators) Run mode Generator running System ready Lost ECM communications Common fault High coolant temperature Low coolant temperature Low coolant level Low oil pressure Not in auto Emergency stop Master switch error Overcrank Overspeed Locked rotor No AC voltage Speed sensor fault Intermittent speed sensor Air damper switch Low fuel High battery voltage Low battery voltage Battery charger ATS emergency on User input #1 User input #2 ECM red alarm ECM yellow alarm Controller application code version Parameter View ECM Information * D D D D D D D D D D D D D D D D D D D D D D D D D D D D D Communication protocol, J1939, MTU, or MTU with VSG D DC voltage at ECM (analog) ECM hours of operation ECM fault code D D D Engine Information (analog) Engine speed, RPM Coolant temperature * Fuel temperature * Charge air temperature * Oil pressure * Fuel pressure * Charge air pressure * D D D D D D D DIP Switch Settings Overspeed: 60 or 70 Hz Temperature cooldown: enabled or disabled Crank mode: continuous or cyclic Engine: non-ECM, DDC/MTU, J1939, or MTU with VSG D D D D * For ECM-equipped engines only Remote Operation (password-protected) Operation Start engine Stop engine Reset faults Modbusr is a registered tradmark of Schneider Electric. G6-76 (Monitor III Software) 6/11b Page 8 Control D D D MPACt 1500 Automatic Transfer Switch Controller The following information is available for both the Normal and Emergency sources. Adjustment screens are password-protected. View Parameter Active Time Delay Time delay name D Time remaining, seconds D Graphic display, time delay elapsed/remain D End time delay button D Common Alarms Common alarms, available and assigned D Audible alarms, available and assigned D Date/Time Date D Time D Synchronize with computer button Daylight saving time enable/disable Clock ahead/behind month, week, day DIP Switch Settings Password enable/disable RO D Maintenance/run mode RO D Spare switch on/off (2) RO D Event History Lost preferred source: last time, date, and D duration Events: D Contactor position changes (transfers) D Faults D Input activation D Output activation D DIP switch position changes D Other events as described in ATS manual D Test button activation/release D Time and date of each event D Save history Clear history Event History View View events for a selected time period D Start date D End date D Get events D Save history button Exercise Calendar Mode Event number D Next start date D Enable/disable each event D Start date Start time D Run time D Loaded/unloaded D Interval D Repeat rate (setup only) Adjust D D D D D D D D D D D D D D D D D Parameter I/O State (on=green, off=gray) Logic board input status Logic board output status I/O module input status I/O module output status Frequency Set Points (Source N, E) Overfrequency dropout Overfrequency pickup Underfrequency pickup Underfrequency dropout Frequency dropout time, seconds Load Control (up to 9 loads) Mode, time-based or current-based for each source Add load (amps, current-based only) Remove load (amps, current-based only) Loads to add (1--9) Add priority (current-based only) Remove priority (current-based only) Add time delay (min:sec, current-based) Remove time delay (min:sec, current-based) Disconnect before transfer time delay, N to E and E to N Reconnect after transfer time delay, N to E and E to N (time-based only) Maintenance History Time not in preferred * Time in standby * Operation time * Switch transfers * Lost preferred source * Failures to transfer * System start date Last maintenance reset date Transfer time, N to E, mS Transfer time, E to N, mS Transfer time, N to open, mS [ Transfer time, E to open, mS [ Transfer time, N to close, mS [ Transfer time, E to close, mS [ Close transfer parallel time (closed-transition) Reset maintenance records button * Total and since reset [ Service entrance models G6-76 (Monitor III Software) 6/11b Page 9 View Adjust D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D MPACt 1500 Automatic Transfer Switch Controller, continued Parameter Programmable Inputs Forced transfer to off Peak shave mode Inhibit transfer Remote end time delay Remote test Low battery voltage Remote common alarm Bypass contactor disable 3 source system disable Remotely monitored inputs #1--4 Programmable Outputs Alarm silenced Audible alarm Preferred source available Standby source available Battery backup low Contactor in preferred poistion Contactor in standby position Contactor in off position Contactor in source N position Contactor in source E position Maintenance mode Not in auto Load control active Low battery on standby source Exerciser active Test mode active Peak shave active Non-emergency transfer Load bank bank active Start source N generator Start source E generator In phase monitor synching Common alarm (1--2) Undervoltage, N and E Overvoltage, N and E Voltage unbalance Loss of phase, N and E Phase rotation error, N and E Overfrequency, N and E Underfrequency, N and E Failure to acquire standby Failure to acquire preferred Failure to transfer I/O module lost comms Aux. switch fault Aux. switch open Load control outputs 1--9 Software-controlled RDO 1--4 3 source system disable View Adjust D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D Parameter View Remote I/O (Input/Output) Software-controlled relay outputs on/off D toggle Remote monitored inputs status D I/O descriptions D Source Information, Normal and Emergency Voltage, line-to-line D Voltage, line-to-neutral D Frequency D Phases, single or three D Selected rotation (ABC/CBA/none) D Actual rotation (ABC or CBA) D System voltage (nominal) D System frequency (nominal) D Line current (accessory required) D System Information Designation (optional, user-defined) D Location (optional, user-defined) D Load branch (optional, user-defined) D Load description (optional, user-defined) D ATS serial number (factory-set) D Contactor serial number (factory-set) D Controller serial number (factory-set) D Software version numbers (controller) D Device ID D MAC address D System Summary System state D Contactor position D Preferred source, N/E D Mode of operation, gen/utility, gen/gen, D utility/utility, or utility/gen/gen Transition mode, open/programmed/closed D Preferred source available D Standby source available D Extended engine start time delay, D enable/disable Commit to transfer, enable/disable D Peak shave delay bypass, enable/disable D In phase monitor, enable/disable D Phase angle Rated current D Loaded remote test, enable/disable D Supervised transfer, mode and switch D position Service entrance type, none/ICCB/MCCB D Closed-transition program override mode, D auto/manual (password-protected) Synchronous closed transition: Voltage phase angle (deg.) D Voltage differential (%) D Frequency differential (Hz) D G6-76 (Monitor III Software) 6/11b Page 10 Adjust D D D D D D D D D D D D D D D D D D D D D D D MPACt 1500 Automatic Transfer Switch Controller, continued Parameter Time Delays Source N engine start Source E engine start Source N engine cooldown Source E engine cooldown Preferred to standby Standby to preferred Fail to acquire standby In phase transfer failure Off-to-standby (programmed-transition) Off-to-preferred, (programmed-transition) Voltage Set Points (Source N, E) Overvoltage dropout Overvoltage pickup Undervoltage pickup Undervoltage dropout Unbalanced voltage enable/disable Unbalanced voltage dropout Unbalanced voltage pickup Debounce time, seconds View Adjust D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D Remote Operation (password-protected) Operation Peak shave start/stop Unloaded test start/stop (remote start/stop) Unloaded sync check start/stop (closed-transition) Loaded test start/stop (remote start/stop) Auto-loaded test start/stop (remote start/stop) Auto test time (1--60 min.) Programmed-transition transfer to OFF/resume normal operation Prime power start/stop Source 1 and source 2 duration (view) Source 1 and source 2 countdown (view) End time delay (active time delay window) Software-controlled relay outputs on/off G6-76 (Monitor III Software) 6/11b Page 11 Control D D D D D D D D D D MPACt 1000 Automatic Transfer Switch Controller The following information is available for both the Normal and Emergency sources. Adjustment screens are password-protected. View Parameter Active Time Delay Time delay name D Time remaining, seconds D Graphic display, time delay elapsed/remain D End time delay button D Common Alarms Common alarms, available and assigned D Audible alarms, available and assigned D Date/Time Date D Time D Synch with system clock Automatic daylight saving time DIP Switch Settings Transfer inhibited/permitted D Test loaded/unloaded D Exercise inhibited/permitted D Manual exercise 1 week/2 week D Exercise loaded/unloaded D Commit/no commit to transfer D Phase rotation ABC/CBA D Event History Lost preferred source: last time, date, and D duration Events: D Contactor position changes (transfers) D Faults D Input activation D Output activation D DIP switch position changes D Other events as described in ATS manual D Test button activation/release D Time and date of each event D Save history button Event History View View events for a selected time period D Start date D End date D Get events D Save history button Exerciser Mode: manual, calendar, or calendar w/ D manual override Next exercise start date D Next exercise start time D Manual exercise period D Loaded/unloaded D Run time D Manual exercise disable button (setup only) D Manual exercise set/end button (setup only) D Exercise time remaining D Adjust D D D D D D D D D D D D D D D D D Parameter View Exercise Calendar Mode Event number D Next start date D Enable/disable each event D Start time D Run time D Loaded/unloaded D Interval D Repeat rate (setup only) Frequency Set Points, (Source N, E) Overfrequency dropout D Overfrequency pickup D Underfrequency pickup D Underfrequency dropout D Frequency dropout time, seconds D Voltage Set Points, (Source N, E) Overvoltage dropout D Overvoltage pickup D Undervoltage pickup D Undervoltage dropout D Debounce time, seconds D Load Control Time Delays (up to 9 loads) Disconnect before transfer time delay, D N to E and E to N Reconnect after transfer time delay, D N to E and E to N Maintenance Records Time not in preferred * Time in standby * Operation time * Switch transfers * Lost preferred source * Failures to transfer * System start date Last maintenance reset date Transfer time, N to E, mS Transfer time, E to N, mS * Total and since reset Source Information, Normal and Emergency Voltage, line-to-line RO Voltage, line-to-neutral RO Frequency RO Phases, single or three RW Selected rotation (ABC or CBA) RW Actual rotation (ABC or CBA) RO System voltage (nominal) RW System frequency (nominal) RW G6-76 (Monitor III Software) 6/11b Page 12 D D D D D D D D D D D D D D D D D D Adjust D D D D D D D D D D D D D D D D D D D D D D D D D MPACt 1000 Automatic Transfer Switch Controller, continued Parameter View System Information Designation (optional, user-defined) D Location (optional, user-defined) D Load branch (optional, user-defined) D Load description (optional, user-defined) D ATS serial number (factory-set) D Contactor serial number (factory-set) D Controller serial number (factory-set) D Software version numbers D System Summary System state D Contactor position D Preferred source, N/E D Mode of operation, D gen-utility/gen-gen/utility-utility Transition mode, open/progammed D Extended engine start time delay, D enabled/disabled Preferred source available D Standby source available D Supervised transfer mode D Supervised transfer switch position D Commit to transfer, enabled/disabled D Peak shave delay bypass, enabled/disabled D In phase monitor, enabled/disabled D Rated current D I/O modules expected D Time Delays Source N engine start D Source E engine start D Source N engine cooldown D Source E engine cooldown D Preferred to standby D Standby to preferred D Acquire standby source D In phase monitor synch D Off-to-standby (programmed-transition) D Off-to-preferred, (programmed-transition) D Programmable Inputs Forced transfer to off D Peak shave mode D Inhibit transfer D Remote end time delay D Remote test D Low battery voltage D Remote common alarm D Bypass contactor disable D 3 source system disable D Adjust D D D D D D D D D D D D D D D D D D D D D D D Parameter Programmable Outputs Preferred source available Standby source available Contactor in preferred poistion Contactor in standby position Contactor in off position Contactor in source N position Contactor in source E position Maintenance mode Not in auto Load control active Low battery on standby source Exerciser started Test mode active Peak shave active Non-emergency transfer Load bank bank active Start source N generator Start source E generator In phase monitor waiting for synch Common alarm (1--2) Undervoltage, N and E Overvoltage, N and E Loss of phase, N and E Phase rotation error, N and E Overfrequency, N and E Underfrequency, N and E Failure to acquire standby Failure to transfer I/O module lost comms I/O module not found Aux. switch fault Aux. switch open Load control outputs 0--8 Software-controlled RDO 1--4 3 source system disable View Adjust D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D Remote Operation (password-protected) Operation Peak shave start/stop System test start/stop (Remote Start/Stop) Programmed transition transfer to OFF/resume normal operation End time delay (active time delay window) Modbus-controlled relay outputs G6-76 (Monitor III Software) 6/11b Page 13 Control D D D D D M340 and M340+ Transfer Switch Controllers All of the following information for M340 and M340+ transfer switch controllers can be viewed through Monitor III. A Modbus/KBUS converter is required for this device. Parameter Date/Time Date Time Frequency Setpoints (Source N, E) Overfrequency dropout Overfrequency pickup Underfrequency pickup Underfrequency dropout Voltage Setpoints (Source N, E) Overvoltage dropout Overvoltage pickup Undervoltage pickup Undervoltage dropout Maintenance History Time not in normal position * Time in emergency * Days of operation * Number of transfers * Last maintenance date System start date Exercise time remaining Last exercise date Last outage date Last outage time Last outage duration View D D D D D D D D D D * Total and since last maintenance D D D D D D D D D D D D Source Info for Source N and Source E Line-to-line voltage Frequency System voltage System frequency D D D D Parameter System Info ATS name Location Load description Branch ATS serial number Controller serial number Number of phases Switch size System Summary Alert code Switch position Programming mode System status messages Time Delays Engine start Normal to emergency Emergency to normal Engine cooldown Before emergency After emergency Sequence to emergency Return to emergency Before normal After normal Sequence to normal Return to normal View D D D D D D D D D D D D D D D D D D D D D D D D Remote Operation (password-protected) Operation Engine run time Set run time (starts engine) G6-76 (Monitor III Software) 6/11b Page 14 Control D D PM340 Power Monitor The following information for the Power Monitor can be viewed through Monitor III software. A Modbus/KBUS converter is required for this device. Parameter Analog Inputs Analog input reading, (2) Auxiliary Inputs Description Inhibit time Date/Time Date Time Electrical Info Voltage, line-to-line Voltage, line-to-neutral Current, L1, L2, L3 Frequency Total kW Total kVAR Power factor Power supply voltage, VDC System Info Generator set name Location Load description Model number Specification number Generator set serial number Controller serial number View D D D D D D D D D D D D D D D D D D D D Parameter System Summary System status Switch position Contactor position Programming mode Test mode timed Test mode active ATS rating Nominal voltage Nominal frequency Phases Connection type History Run time, normal Run time, emergency Run time, off Event history, date and event description (code) View D D D D D D D D D D D D D D D Remote Operation (password-protected) Operation Engine run time Set run time (starts engine) G6-76 (Monitor III Software) 6/11b Page 15 Control D D Connection Types Local Connections A personal computer (PC) can communicate with generator set controllers, transfer switch controllers, and power monitors using local, remote modem, or remote network (Ethernet) connections. A PC connects directly to a device or network of devices with an RS-232 cable or an RS-485 cable. Connection Notes: D A device in the following diagrams is any generator set controller, transfer switch controller, or power monitor listed on page 1 of this document. All devices must be configured for Modbus communication. PC RS-232 D RS-485 connects up to 247 devices with a maximum total cable length of 1220 m (4000 ft.). Use a terminating resistor on the last device in the network. See EIA standards. D The 550 controller can act as an RS-232 to RS-485 port converter when the controller is located within 15 m (50 ft.) of the PC. RS-232 to RS-485 port converter Device RS-485 PC D The Decision-Makert 3+ and MPACt 1000 controllers must use RS-485 connections for Monitor III communications. RS-232 D The Decision-Makert 340, M340, M340+, and PM340 Power Monitor require Modbus/KBUS converters. D The MPACt 1500 ATS controller uses RS-485 and Ethernet connections. Device * RS-232 to RS-485 port converter PC D A Modbus/Ethernet converter is required for remote network (Ethernet) connections to all devices except the MPACt 1500 ATS controller. RS-485 Device RS-485 D RS-232 connects up to 15.2 m (50 ft.) from PC’s serial port. RS-232 * RS-485 Device Terminating resistor Additional devices * Some devices can use RS-232 connections. See Connection Types. G6-76 (Monitor III Software) 6/11b Page 16 Remote Modem Connections The PC and device(s) are connected by modems. The PC communicates with the device or device network via a telephone network, and the PC can be located anywhere a telephone line can be accessed. Telephone line from modem Telephone lines RS-232 * Device modem Device * PC w/modem Telephone line from modem RS-485 RS-232 Device modem RS-232 to RS-485 port converter Device RS-485 Telephone lines PC w/modem RS-485 Device Device Terminating resistor * Some devices can use RS-232 connections. See Connection Types. Remote Network Connection (Ethernet) A PC with a network interface card is connected to the Ethernet network. The 1500 ATS controller has an RJ-45 connector for direct Ethernet connection. Other devices can connect together using RS-485 connections and connect to the Ethernet network through a Modbusr/ Ethernet converter. The PC can be located anywhere the site’s Ethernet network can be accessed. Modbusr TCP/IP PC with network interface card Modbusr TCP/IP Ethernet Network 1500 ATS Controller Modbusr TCP/IP Category 5 Modbusr TCP/IP Category 5 Modbusr RTU Device RS-485 Converter, Modbusr/ Ethernet RS-485 Device PC with network interface card RS-485 Terminating resistor G6-76 (Monitor III Software) 6/11b Page 17 Additional devices KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KohlerPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Network Communication Products and Accessories - Monitor III software kit with hardware key. Includes: d Software CD-ROM d Null modem cable d Network termination resistor d Operation manual and connection instructions - Monitor III software kit with hardware key and device modem for remote connections. Includes: d Software CD-ROM d AT modem cable d Device modem, 120VAC/60Hz, 19.2k baud d Optical isolator d Converter, RS-232/ RS-485 d Connector, 9-pin/ 25-pin d Null modem, 25-pin d Network termination resistor d Operation manual and connection instructions - Device modem kit, 50Hz, 19.2k baud - Modbusr/Ethernet converter kit. Includes DC adapter with universal AC plug. (RS-485/ RJ-45 connectors; required for TCP/IP connections. Not required for the MPACt 1500 ATS controller). - Modbusr/ KBUS converter kit for the following devices (required for Monitor III or other Modbusr communication): - Decision-Makert 340 generator set controller - M340 and M340+ transfer switch controller - PM340 power monitor - Modbusr communication board for Decision-Makert 3+ generator set controllers (required for Monitor III or other Modbusr communication) - RS-232/ RS-485 port converter - Null modem cable, 9-pin/ 9-pin DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr generator distributor for availability. © 2005, 2006, 2011 by Kohler Co. All rights reserved. G6-76 (Monitor III Software) 6/11b Page 18 TIB-114 TECHNICAL INFORMATION BULLETIN Generator Set Sound Data Sheet Sound Pressure Data in dB(A) Generator Set Model Hz 400REOZJB 60 Load 100% Load No Load Raw Exhaust 119.5 102.6 Open Unit, Isolated Exhaust Weather Enclosure Level 1 Sound Enclosure Level 2 Sound Enclosure 94.8 90.4 92.9 88.5 84.7 74.6 75.6 72.5 Note: Sound pressure data is the logarithmic average of eight perimeter measurement points at a distance of 7 m (23 ft.), except Raw Exhaust data which is a single measurement point at 1 m (3.3 ft.) from the mouth of a straight pipe exhaust. 400REOZJB Load 100% Load Distance, m (ft) 7 (23) 60 Hz Enclosure Level 2 Sound Sound Pressure Levels, dB(A) Measurement Clock Position Octave Band Center Frequency (Hz) 3:00 1:30 12:00--Engine 10:30 9:00 7:30 6:00--Alternator 4:30 63 60.8 57.9 58.9 60.6 61.7 56.6 56.4 59.4 125 67.8 64.4 65.5 68.3 68.5 64.4 64.8 67.5 250 69.1 68.6 64.3 68.7 63.9 71.3 72.6 72.6 500 71.0 70.8 70.8 70.7 69.0 66.9 67.3 68.8 1000 69.7 66.8 65.7 69.7 67.8 69.0 62.5 68.6 2000 65.4 64.7 63.8 67.2 65.2 67.3 57.2 66.9 4000 61.5 61.5 61.1 62.4 60.4 60.7 53.6 64.6 8000 54.5 56.9 50.2 54.7 55.3 54.9 42.5 56.1 8--pos. log avg. 59.4 66.7 69.9 69.7 67.9 65.5 61.5 54.5 Overall Level 76.3 75.1 74.2 76.4 74.7 75.6 74.7 76.8 75.6 Sound Pressure Levels, dB(A) Load 100% Load Distance, m (ft) 7 (23) Enclosure Measurement Clock Position Level 1 Sound 3:00 1:30 12:00--Engine 10:30 9:00 7:30 6:00--Alternator 4:30 8--pos. log avg. Octave Band Center Frequency (Hz) 63 57.5 62.6 63.2 60.2 62.8 57.4 58.7 59.3 60.8 125 69.1 71.4 70.7 69.3 71.7 68.2 66.8 69.3 69.8 250 78.0 75.6 76.0 78.5 74.2 72.6 76.3 77.0 76.3 500 74.9 77.6 79.3 76.5 72.7 72.0 75.6 76.4 76.2 1000 76.9 79.6 79.3 76.6 73.2 74.9 74.2 74.4 76.7 2000 80.1 82.0 85.6 81.6 72.9 74.9 72.6 75.9 80.4 4000 74.9 79.5 80.9 75.9 67.4 69.2 68.4 71.7 76.0 8000 65.6 68.4 71.3 66.7 61.1 62.6 63.4 62.9 66.5 Overall Level 84.6 86.6 88.6 85.5 80.4 80.6 81.4 82.7 84.7 Sound Pressure Levels, dB(A) Load Distance, m (ft) Enclosure Measurement Clock Position 3:00 1:30 12:00 10:30 Eng. 9:00 7:30 6:00 Alt. 4:30 8--pos. log avg. 100% Load 7 (23) Weather Overall Levels 93.8 92.5 92.0 94.5 93.8 87.6 92.0 92.9 94.1 Sound Pressure Levels, dB(A) Load 100% Load Distance, m (ft) Measurement Clock Position 7 (23) 3:00 1:30 12:00--Engine 10:30 9:00 7:30 6:00--Alternator 4:30 8--pos. log avg. Open Unit, Isolated Exhaust Octave Band Center Frequency (Hz) 63 60.2 57.6 66.3 64.9 66.1 64.1 64.5 60.9 63.9 125 71.0 69.6 73.5 74.7 75.4 73.4 73.7 70.8 73.1 250 81.2 86.6 87.1 87.5 85.3 86.1 82.8 79.9 85.3 500 84.3 86.9 83.0 85.1 85.3 82.8 82.9 82.4 84.4 1000 88.3 87.5 88.7 90.3 89.3 89.1 81.2 87.6 88.3 2000 91.6 87.9 88.7 91.3 93.2 92.2 84.0 89.9 90.6 4000 86.9 83.9 82.6 86.4 86.3 85.8 77.5 85.3 85.0 8000 87.8 85.1 77.5 81.8 84.5 82.3 74.3 83.7 83.6 Overall Level 95.7 94.4 93.9 96.0 96.4 95.7 89.5 93.9 94.8 The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. 2013 by Kohler Co. All rights reserved. TIB-114 400REOZJB 60 Hz 12/13c 1 Attachment 2 Table of Contents; Over view Unit Brochure Engine Datasheets Alternator Datasheets Genset Controller Datasheets Breaker Datasheet Battery Charger Datasheet Water Heater Datasheet Genset Layout Drawing Fuel Tank Layout Drawing Electrical Wiring Diagram Standard Warranty Policy Start-up Check List Data Diesel Generating Set Installation & Operation Manual 2 AKSA APD-ULJ400 GENERATOR SET TECHNICAL SPECIFICATIONS AKSA GENERATOR SET Manufacturer: Aksa Power Generation Standards: The equipment meets the following standards; - UL2200 Listed - ISO3046, VDE0530, BS4999, BS5000, IEC34 - The generator sets are manufactured by a fully accredited ISO9001 facility. Rating : - please refer to technical brochure given attached. Standby rating : 400 kW Full Load Current : 601.4A (U = 480Vac, Cosφ = 0,8) Full Load Current : 1387.9A (U = 208Vac, Cosφ = 0,8) Frequency / Speed : 60Hz / 1800rpm Voltage Regulation : ± 1.0% Diesel Engine: - please refer to technical brochure and engine datasheet given attached. John Deere diesel engine, model 6135HFG84 The engine is of the heavy duty industrial type with 4 stroke compression ignition and is fitted with all accessories to provide a reliable power supply. These accessories include, among others, a cartgridge type dry air filter and a mechanical governor. The engine cylinder block is cast in one piece cast iron, vertical cylinders inline overhead valves and camshaft in block. The cylinder head is made of special cast iron. The thermally loaded flame plate is efficiently water cooled. The crankshaft is forged in one piece in a high tensile steel. Lubrication: forced lubrication via gear pump, special paper cartridge type filters, lubricant cooling via heat exchanger on most versions. Air Cooling Cubic Capacity Cylinders and Build Governor Type Fuel Consumption Coolant Capacity Radiator Ambient Temp. EPA Certification : Turbocharged & Air to Air Aftercooled : 824 cu.in (13.5lt) : 6 In-line : Electronic : 100% load 29.2 gal/h 75% load 23.9 gal/h 50% load 16.8 gal/h 25% load 9.0 gal/h : 18.0 gallons (engine) : 50 °C : Tier 3 3 Cooling System: The engine cooling system is water cooled. The water cooled system is comprised of a radiator, a pusher fan and thermostat. The alternator has its own internal fan to cool the alternator components. Standard operating temperature of the radiator is 122°F (50°C) Alternator: - please refer to technical brochure and engine datasheet given attached. Stamford, brushless alternator, model; HCI444F Horizontal axle alternator (synchronous three phase), on rolling bearings, selfventilated within the the room with low loss silicon-sheet stator bundle, electrolytic copper winding with class H insulation. The output electrical power is normally produced by a screen protected and dripproof, self-exciting, self-regulating, brushless alternator. Fine tuned to the output of this generating set. Mounted on the top of the alternator is a sheet steel terminal box. Alternator meets the following specs: - Brushless, single bearing system, 4 poles - Insulation class H - Standard degree of protection IP23 - Self-exciting and self-regulating - Stator winding with 2/3 pitch for improved harmonics - Impregnation with tropicalised epoxy varnish - Solid state Automatic Voltage Regulator - Voltage regulation of 1% - AC Waveform Total Harmonic Distortion: No Load < 1.5%, Non-distorting balanced linear load < 5% - Telephone Influence Factor (TIF): <50 Per NEMA MG1-22.43 - Telephone Harmonic Factor (THF): <2% Coupling: Engine and alternator are firmly joined by a coupling cone that guarantees the proper assembly coaxiality. Mono-support machines are also used. A special flexible disk is used in the place of a flexible coupling. Fuel Tank and Base Frame: The engine and alternator are coupled together and mounted on a heavy duty steel baseframe. US made, UL142 listed, double wall, minimum 24 hours capacity at full load base designed fuel tanks supplied as an option. Fuel tank comes standard with vent caps, fuel sensors and fuel gauge. Vibration Isolation: The generator set is fitted with vibration isolators which are designed to reduce engine vibration being transmitted to the foundation on which the generating set is mounted. These isolators are fitted between the engine/alternator feet and the baseframe. Silencer and Exhaust System: Exhaust gases from the turbocharger are discharged toward atmosphere through a silencer. These should be vented as high as possible, and must be prevented from reentering the engine via the charge intake, or polluting the radiator fins. 4 It is important to note that the turbocharger nozzles must always be free of loads. Stainless steel exhaust compensator(s) is fixed on exhaust system of generator set. Rain cap is installed to prevent water entering the silencer and the engine. A residential or critical grade exhaust silencer is provided and installed inside the canopy of the generating set. The silencer and exhaust system reduces the noise emission from the engine and can direct exhaust gases to safe outlets. The exhaust silencer is made of a carbon steel receiver containing a sound attenuator and wave de-phasing system made of perforated steel and heavy rock wool. It is asbestos free. Control System: - please refer to technical brochure and engine datasheet given attached. Deep Sea Electronic, model 7320 consisting of microprocessor logic with the following features: • Stop/Reset, Auto, Manual, Start pushbutton • LCD Display Scroll pushbutton • Event Log pushbutton • LCD display • LED indication icons Metering via the LCD display: • Generator Volts L1-N, L2-N, L3-N • Generator Volts L1-L2, L2-L3, L3-L1 • Generator Amps L1, L2, L3 • Generator Frequency Hz • Engine Speed RPM • Engine Oil Pressure • Engine Temperature • Plant Battery Volts • Engine Hours Run • Generator kVA • Generator kW • Generator Power Factor • Fuel level (optional) • Mains Volts L1-N, L2-N, L3-N • Mains Volts L1-L2, L2-L3, L3-L1 • Mains Frequency Hz Alarm Functions: • Engine functions: - High coolant temperature - warning / shutdown - Low coolant level - Low oil pressure - warning / shutdown - Under/Over speed - warning / shutdown - Charge Fail - warning - Fail to start - Fail to stop - Emergency stop - Under/Over Generator Volts - warning / shutdown - Under/Over Generator Frequency - warning / shutdown - Over current - warning / shutdown 5 - Low/High DC Battery Volts - warning - Low Fuel Alarm – warning (optional) - Loss of speed sensing signal - Mains out of limits - Mains under/over Volts - Mains under/over Frequency Additional Standard Functions: • Adjustable crank cycle/attempts • Built in Exercise Scheduler • Graphic Icon based LCD Display for true Multi-lingual use • Event Logging of Shutdown Alarms. This records the last 15 shutdown alarms • 6 fully configurable auxiliary inputs • 3 configurable outputs • Full Remote Control and Telemetry (Option) • System lock input • Front panel configuration of timers and alarm trip points • SMS messaging capability with suitable GSM Modem Generator Set Standard Accessories: • 24 Vdc electrical system • Battery charge alternator • 24 Vdc engine starter motor • Electronic governor • Starting batteries, Maintenence free Lead-Acid type • UL2200 listed and approved battery charger • Muffler inside of enclosure • Exhaust flexible coupling • Factory installed vibration isolators • Main line output circuit breaker • Engine block heater • Modular design, electrostatic polyester powder painted steel enclosure Dimensions: - please refer to given technical brochure and layout drawing Sound Attenuated Level-1 Enc. (LxWxH) in. : 205.7 x 74.8 x 88.1 (w/o tank) Dry weight (Level-1 Canopy Type) lb. : 9000 Sound Attenuated Level-2 Enc. (LxWxH) in. : 205.7 x 74.8 x 112.1 (w/o tank) Dry weight (Level-2 Canopy Type) lb. : 9750 Warranty: - please refer to warranty guide given attached. • 24 Months from date of start up / 2000 hours which ever first. • Genset should be serviced every 250 hrs. & genuine spare parts should be used for genset maintenence. Sound Attenuated Enclosure: Manufacturer: Aksa Power Generation Type: Sound attenuated level-1 to provide 79dBA @ 7m(23ft), 88dBA @ 1m(3.28ft) Sound attenuated level-2 to provide 76dBA @ 7m(23ft), 85dBA @ 1m(3.28ft) 6 • • • • • • • • • • • • • • Modular design (sheet steel) Sound proof Anti-corrosion powder coated phosphate priming. Color black / beige (RAL9005 / RAL1015) Insulated with acoustic foam lining Easy lifting and moving Lockable doors with key Protective mesh for rotating parts Exterior emergency stop push button Thermally insulated engine exhaust system Doors on each side Panel window Access to radiator filling or cap Oil drains and breather (sump) extended outside canopy Generator Factroy Test Procedure: Each Aksa UL2200 listed genset is subjected to a factory test according to UL2200 standards and regulations. Preparations and Controls before test: • Leakage and exhaust connection control • Engine oil level and radiator water level control • Water filter valve control • Oil and water hose clamps control • Fan belt tension control • Charging alternator belt tension control • Rubber wedge level control • Alternator, panel cable cross sections and mountings check • Terminals connection tightness control • Symmetry axis of distance between radiator and fan control • Grounding cable connection control • General control such as tools, nuts, bolts in testing area to be cleaned. Controls during the test: • Engine noise control to determine if it runs properly • Voltage control by multimeter and verify with DSE controller • Frequency control by multimeter and verify with DSE controller • Rectifier voltage control • Charging alternator voltage control • Oil and water leak physical control • Vibration control • Two wire start control • Cooling time function control • Emergency stop function control • Alternator voltage failure control • Over heating failure control • Overspeed failure control • Low oil pressure failure control • Low water level failure control (if switch fitted) 7 • Start failure control • Measuring devices and accuracy control • Air inlet for airflow control for turbo charged units • Turbocharge lubricant pipe leakage control Load test: • Load test to be subjected as; - 0% of nominal power 5min. - 25% of nominal power 5min. - 50% of nominal power 5min. - 75% of nominal power 5min. - 100% of nominal power 5min. - 110% of nominal power 15min. • Each unit subjected to load/unload of 50% of nominal power 3 times. • Below values have been recorded during load testing; - Load % - Cooling Temperature (ᵒC) - Oil pressure (bar) - Iu (A) - Iv (A) - Iw (A) - Uph-ph (V) - Frequency (Hz) - Power (kW) - Cos ᶲ - Power (kVA) Controls after test: - Battery cables connection control - Radiator water drain control - Oil drain oil hose connection control - Oil and water hoses connection control - Lower teminal cover bolts tightening control 8 APD-ULJ400 AKSA Power Generation has been producing industrial generator sets with an innovative compact design and excellence in quality for over 30 years. AKSA has been providing reliable power through three main production plants and over 15 branch offices worldwide. Alternator (125 ⁰C Rise) HCI434F Winding #311 Stand-by Ratings Voltage Ph Pf Prime Ratings Hz kW/kVA Amp kW/kVA Amp 480/277V 3 0.8 60 400/500 601 NA NA 440/254V 3 0.8 60 400/500 656 NA NA 416/240V 3 0.8 60 400/500 694 NA NA 240/139V 3 0.8 60 400/500 1203 NA NA 240/120V 3 0.8 60 400/500 1203 NA NA 208/120V 3 0.8 60 400/500 1388 NA NA Rating Definition Stand-by Power (Maximum): Power available at variable load in the event of main power network failure. No over load is permitted. Prime Power: Power available at variable load in lieu of a main power network. Overload of 10% is permitted for 1 hour in every 12 hours of operation. The above ratings represent the engine performance capabilities to conditions specified in accordance with ISO 8528/5 & ISO3046. Derating may be required for conditions outside of the test conditions. Codes & Standards U.S.EPA Standard Features EPA Certified Tier3 for Emergency Stationary Applications. AKSA Power Generation provides single source responsibility for the generator set & accessories. The Generator set is UL2200 listed. Dual wall UL142 listed fuel tanks are also available. The generator set, with its components, are prototype tested and production tested according to the UL test program. The Generator set is designed and manufactured in a facility certified to ISO9001 standards. The Generator set is designed and manufactured in a facility certified to ISO14001:2004 standards. The Generator meets NFPA70, 99, 110, 37 Level 1 when equipped with the necessary accessories and installed per NFPA standards. John Deere heavy duty four cycle industrial diesel engine delivers low emission, reliable power, fuel efficiency and fast response to load changes. Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant sections of other international standards such as BS5000, VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Non-proprietary NFPA110 compliant control system provides total gen-set system integrated control, protections, metering, automatic starting/stopping with options of remote control, remote display or remote annunciation. Heavy duty base frame with integral pad vibration isolators eliminates the need for under unit spring vibration isolators. www.aksausa.com APD-ULJ400 Fuel Consumption (gal/hr) Engine Data Manufacturer John Deere 100% Load - Standby 29.2 Model 6135HFG84 75% Load - Standby 23.9 Cylinders 6, In-line 50% Load - Standby 16.8 Max. power @ rated rpm; kWm (BHP) 460 (617) 25% Load - Standby 9.0 Brake mean effective pressure; kPa 2271 Aspiration & Cooling Turbocharged & air to air aftercooled Total displacement; L (in3) 13.5 (824) Bore; in. (mm) 5.2 (132) Stroke; in. (mm) 6.5 (165) Compression ratio 16:1 Governor type Electronic Engine crankcase vent system Exhaust System Exhaust gas flow; (m3/min) 73.8 Max. allowable exhaust restriction; (kPa) 7.5 Max. exhaust gas temp; (⁰C) 527 Max. bending moment on turbo outlet; (lb-ft) 5.2 Open Cooling System Engine Electrical System Charging alternator Radiator ambient temp; ⁰C (⁰F) 24V, Negative Ground Engine coolant capacity; L Starter rolling current @32 ⁰F; (amp) 600 Min. coolant fill rate; L/min (gal/min) Min. voltage at ECU during cranking; (dc) 10 Thermostat operation range; ⁰C Max. allowable start circuit resistance; (Ohm) Starter motor rated voltage; (dc) Battery quantity x rating & CCA 0.002 24 2 x 120Ah, 850 Max top tank temp; ⁰C Min. limiting ambient temp; ⁰C Cooling fan type Fuel System L15 Controller Fuel injection pump Unit injection Governor Type Electronic Total fuel flow; lb/hr 357 Fuel temp rise, inlet to return; ⁰C 47 Max fuel inlet temp; ⁰C 100 Max fuel inlet restriction; in.H2O (kPA) 40 (10) Max. fuel return pressure; in.H2O (kPA) 140 (35) Fuel filter @98% efficiency m3/min Intake manifold pressure; (psi) ECU Description 2 mic 18 12 (3.2) 82-92 105 47 Pusher Max. External coolant restriction; (psi) Engine air flow; 50 (122) Engine coolant flow; L/min (gal/min) 6 28.2 39.4 400 (124) Engine heat rejection; BTU/min 11839 Air cleaner efficiency 99.9% Lubrication System Oil pressure @rated speed; psi In pan oil temp.; ⁰C Max. oil carryover in blow by; lb/hr Max. air flow in blow by; gal/min Max. crankcase pressure; in. H2O (kPa) www.aksausa.com 34 113 0.007 79.3 2 (0.5) APD-ULJ400 Alternator Data Control System Manufacturer Stamford Model HCI434F Design 4 Pole, drip proof rotating field Exciter type Brushless, self excited P.M.G. option is available Stator 2/3 winding pitch Rotor Single bearing, flexible disc Leads 12 Efficiency 480V 93.7 208V 93.4 Voltage regulator Solid state, Volts/Hz Voltage regulation Self excited 1% PMG 0.5% Insulation Class H Protection IP23 Temp. rise @ 40⁰C ambient 125⁰C Prime 150⁰C Standby Alternator Cooling Direct drive Centrifugal Blower Cooling air; 0.8 m3/min Waveform distortion No load < 1.5% Non-distorting balanced linear load <5% Max. over-speed; rev/min 2250 Telephone influence factor (TIF) <50 Telephone harmonic factor (THF) <2% DSE7320 is an advanced control system, suitable for a wide variety of single, diesel or gas, gen-set applications. Monitoring and an extensive number of engine parameters, the module displays warnings, shutdowns and engine status information on the back lit LCD screen, illuminated LEDs, remote PC and via SMS text alerts (with external modem). • UL recognized, NFPA110 Level 1 compatible • LCD text display, key menu navigation and front panel editing • Off/Manual/Auto model switch • Two wire starting/stopping in Auto mode • Engine exerciser • IP65 front panel rating with supplied sealing gasket • Configurable 9 inputs, 8 outputs with expansion capability • Real time clock provides accurate event logging • Fully configurable via DSE Configuration Suite PC software • Remote SCADA monitoring and BMS integration features • License free PC software Sustained short circuit current 10sec; (amp) Protections Instruments • Gen. Voltage - under/over Star (WYE) 2000 • Gen. Voltage (L-L/L-N) • Gen. Frequency - under/over • Gen Frequency Parallel Star (Low WYE) 4000 • Engine Speed - under/over • Engine Speed • Engine Oil pressure - low • Oil Pressure • Engine Temp. - low/high • Water Temperature • Battery Voltage - low/high • Battery Voltage • Weak battery • Run time • Fail to start/stop • Engine maintenance due • Charge fail • Phase sequence • Over current & load(kW/kVAr) • Pwr. monitoring Locked rotor kVA (skVA) @30% voltage dip Self Excited PMG Excited 480/277V - 3ph 1050 1270 208/120V - 3ph 730 980 • Unbalanced loa (kWh / kVAh / kVArh) • Independent Earth Fault • Power (kW/kVA/kVAr) • Reverse Power • Power factor • Fuel level - low/high (optional • Gen. Current (L1-L2-L3) • Loss of speed signal • Earth current www.aksausa.com APD-ULJ400 Standard Features & Accessories Optional Accessories • UL2200 Listing • Upsized Alternator • Sound Attenuated Steel Enclosure • PMG Excitation • 150mph Wind Rating • Alternator Anti-condensation Heater • Heavy Duty Steel Base-frame • Manual Speed Adjust • Anti-vibration pads • Sub Base Fuel Tank (UL142 / UL2085) • Residential Grade Silencer Inside Enclosure • Low Fuel & Fuel Leak Alarms • Flex Fuel Lines • Fuel Level Monitoring on Controller & High Fuel Alarm • Oil Drain Valve & Extension • Spring Anti-vibration pads • Emergency Stop Switch • Critical Grade Silencer • Battery, Battery Rack & Cables • Fuel Line Check Valve • Battery Charger (2.5 Amp) • Oil Temperature Gauge • Main Line CB (80% rated) • Remote Emergency Stop Switch • Jacket Water Heater (3000W) • Battery Restraint • Operations Manual • Battery Charger 10/20Amp per NFPA110 • 2 Years / 2000hours Limited Warranty • Main Line CB (100% rated) • Main Line CB Shunt Trip Dimensions & Weight & Sound Level • Remote Serial Display Panel • Remote Annunciation Panel (8/16/24 lights) Gen-set Without Fuel • 5 Years / 2000hours Limited Warranty Open Type Enclosed Type Level 1 Level 2 205 205 L (in.) 157 W (in.) 75 75 75 H (in.) 78 88 112 6400 9000 9750 79 76 Weight (lb) Sound Level (dBA@23ft) Fuel Tank – UL142 24h(665gal) 48h(1400gal) 72h(2100gal) L (in.) 205 205 260 W (in.) 75 75 75 H (in.) Weight (lb) 17 2800 33 3700 36 4710 *Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice. AKSA POWER GENERATION USA LLC 371 Exchange Street, West Monroe, LA 71292 Tel: 318.855.8377 Fax: 318.855.8381 E-mail: sales@aksausa.com AKSA Power Generation USA is a member of www.aksausa.com ENGINE PERFORMANCE CURVE PowerTech™ E 13.5L Engine Model:6135HFG84 JD Electronic Control Gross Power Rating: Application: Generator Emergency Stationary (400 kWe Market) 1800 RPM (60 Hz) NA hp (NA kW) Prime 617 hp (460 kW) Standby Nominal Engine Power @ 1800 RPM Prime Generator Efficiency % 90-94 STANDARD CONDITIONS ______________________ Standby HP kW HP kW NA NA 617 460 Fan Power (% of Standby) hp kW 24.7 18.4 Power Factor 0.8 Prime Rating Air Intake Restriction......................................12 in.H2O (3 kPa) Exhaust Back Pressure...............................60 in.H2O (15 kPa) Standby Rating kWe kVA kWe kVA NA NA 397-415 497-519 Gross power guaranteed within + or - 5% at SAE J1995 and ISO 3046 conditions: 77 °F (25 °C) air inlet temperature 29.31 in.Hg (99 kPa) barometer 104 °F (40 °C) fuel inlet temperature 0.853 fuel specific gravity @ 60 °F (15.5 °C) Conversion factors: Power: kW = hp x 0.746 Fuel: 1 gal = 7.1 lb, 1 L = 0.85kg Torque: N·m = lb-ft x 1.356 Note 1: Based on nominal engine power; Fan Power is 4% of Standby. All values are from currently available data and are subject to change without notice. Notes:A crankshaft Torsional Vibration Analysis is required on all Gen Set applications. Designed/Calibrated to meet: Certified by: • EPA Tier 3 Ref: Engine Emission Label Performance Curve: 6135HFG84_A Engine Performance Curves 6135 - Generator August 2013 Engine Installation Criteria General Data Electrical System Model 6135HFG84 Recommended Battery Capacity, 12V @32 °F (0 °C) 1900 amps 6 Recommended Battery Capacity, 24V @32 °F (0 °C) 925 amps 5.2 in. Starter Rolling Current, 12V @32 °F (0 °C) 920 amps Number of Cylinders Bore 132 mm Stroke 165 mm 6.5 in. Starter Rolling Current, 24V @32 °F (0 °C) Displacement 13.5 L 824 in.³ Starter Rolling Current, 12V @-22 °F (-30 °C) 1300 amps Starter Rolling Current, 24V @-22 °F (-30 °C) 700 amps Compression Ratio 16.0 : 1 Valves per Cylinder, Intake/Exhaust Firing Order Combustion System Engine Type Aspiration 600 amps 2/2 Min. Voltage at ECU during Cranking, 12V 6 volts 1-5-3-6-2-4 Min. Voltage at ECU during Cranking, 24V 10 volts Unit Injection Max. Voltage Drop, Battery to Starter 0.8 volts In-line, 4 Cycle Max. Allowable Start Circuit Resistance, 12V 0.0012 Ohm Turbocharged and air-toair aftercooled Max. Allowable Start Circuit Resistance, 24V 0.002 Ohm Engine Crankcase Vent System Max. Voltage From Engine to Crankshaft, 12V Open 0.15 volts Max. Voltage From Engine to Crankshaft, 24V Physical Data 0.15 volts Max. ECU Temperature 105 °C 221 °F Max. Harness Temperature 125 °C 257 °F Length 1362 mm 53.6 in. Max. Alternator Temperature 120 °C 248 °F Width 857 mm 33.7 in. Max. Starter Temperature 120 °C 248 °F Height 1210 mm 47.6 in. Max. Temperature, All Other Electronics 125 °C 257 °F Weight, with oil &no coolant (Includes engine, flywheel housing, flywheel &electrics) 1334 kg 2941 lb Center of Gravity Location, X-axis From Rear Face of Block -522 mm -20.6 in. Center of Gravity Location, Y-axis Right of Crankshaft -23.3 mm -0.9 in. Center of Gravity Location, Z-axis Above Crankshaft 254.5 mm 10.0 in. Max. Allowable Static Bending Moment At Rear Face of Flywheel Housing with 5-G Load 814 N·m 600 lb-ft Thrust Bearing Load Limit Forward, Intermittent 8100 N 1821 lb Thrust Bearing Load Limit Forward, Continuous 5400 N 1214 lb Thrust Bearing Load Limit Rearward, Intermittent 4000 N 899 lb Thrust Bearing Load Limit Rearward, Continuous 2500 N 562 lb Max. Continuous Damper Temp Max. Torsional Vibration, Front of Crank 82 °C 180 °F 0.36 DDA Performance Curve: 6135HFG84_A Engine Performance Curves 6135 - Generator Sheet 2 - August 2013 Engine Installation Criteria Charge Air Cooling System Exhaust System Air-to-Air Heat Rejection 94 kW Intake Manifold Pressure 271.9 kPa 5350 BTU/min Exhaust Flow 73.8 m³/min 39.4 psi Exhaust Temperature 527 °C Max. Allowable Exhaust Restriction 7.5 kPa Min. Allowable Exhaust Restriction 4 kPa 16 in. H2O Max. Bending Moment on Turbo Outlet 7 N·m 5.2 lb-ft Compressor Discharge Temperature @77°F(25°C) Ambient Air 220 °C 428 °F Compressor Discharge Temperature @117°F(47°C) 80 kPa Barametric pressure 260 °C 500 °F 88 °C 190 °F Intake Manifold Temperature at which Power De-rate Occurs 121 °C 250 °F Intake Manifold Temperature at which Severe Power Derate Occurs 123 °C 253.4 °F Max. Temperature Out of Charge Air Cooler @All Ambient Conditions Max. Shear on Turbine Outlet ECU Description 57 quart Max. Pressure Drop through CAC 13 kPa 52.0 in. H2O Governor Regulation Min. Pressure Drop through CAC 8 kPa 32.0 in. H2O Total Fuel Flow 113 °F Max. Bending Moment on Compressor Outlet Max. Shear on Compressor Outlet 7 N·m 11 kg 5 lb-ft 24 lb Cooling System Engine Heat Rejection 208 kW 11839 BTU/min Engine Radiated Heat 20 kW 1138 BTU/min 400 L/min 106 gal/min Coolant Flow Thermostat Start to Open 82 °C 180 °F Thermostat Fully Open 92 °C 198 °F Engine Coolant Capacity 18 Liter 19.0 quart Min. Coolant Fill Rate 12 L/min Min. Pressure Cap 100 kPa Min. Pump Inlet Pressure @203°F (95°C) Coolant 30 kPaa 4 psia Max. External Coolant Restriction 40 kPa 6 psi Max. Top Tank Temperature 105 °C 221 °F Max. Top Tank Temperature 95% of Operating Hours 95 °C 203 °F Min. Limiting Ambient Temperature 47 °C 117 °F 30 in. H2O 24 lb L15 Controller Unit Injection Governor Type Electronic Selectable 162 kg/hr 357 lb/hr Fuel Consumption 94 kg/hr 207.2 lb/hr Fuel Temperature Rise, Inlet to Return 47 ∆°C 85 ∆°F Max. Fuel Inlet Restriction 10 kPa 40 in. H2O Min. Fuel Inlet Pressure -10 kPa -40 in. H2O Max. Fuel Inlet Pressure 24 kPa 96 in. H2O 35 kPa 140 in. H2O Max. Fuel Return Pressure Max. Fuel Inlet Temperature 100 °C Fuel Filter @98% Efficiency 212 °F 2 mic Lubrication System 3.2 gal/min 15 psi 11 kg Fuel Injection Pump 54 Liter 45 °C 981 °F Fuel System Max. CAC System Volume Max. Temperature Out of Charge Air Cooler @77°F (25°C) Ambient Air 2606 ft.³/min Oil Pressure at Rated Speed 234 kPa In-Pan Oil Temperature 113 °C Max. Oil Carryover in Blow-By 3 g/hr Max. Airflow in Blow-By 300 L/min Max. Crankcase Pressure 0.5 kPa 34 psi 235 °F 0.007 lb/hr 79.3 gal/min 2 in. H2O Performance Curve: 6135HFG84_A Engine Performance Curves 6135 - Generator Sheet 3 - August 2013 Engine Installation Criteria Air Intake System Engine Air Flow 28.2 m³/min Air Mass Flow 1940 kg/hr Maximum Allowable Temperature Rise, Ambient Air to Engine Inlet 996 ft.³/min 4277 lb/hr 8 ∆°C 15 ∆°F Max. Air Intake Restriction, Clean Air Cleaner 3.75 kPa 15.0 in. H2O Max. Air Intake Restriction, Dirty Air Cleaner 6.25 kPa 25.0 in. H2O Air Cleaner Efficiency 99.9 % Performance Data Rated Power, Prime NA Rated Power, Standby 460 kW NA 617 HP Rated Speed 1800 rpm Rated Torque, Prime NA Rated Torque, Standby 2440 N·m 1800 lb-ft BMEP, Prime NA BMEP, Standby 2271 kPa Altitude Capability 914 m Friction Power @Rated Speed 329 psi 3000 ft 41 kW Air:Fuel Ratio 55 HP 20.6 : 1 Smoke @Rated Speed 0.29 Bosch No. Noise @1 m 98.9 dB(A) 0-100% Standby Load Acceptance 11.5 sec Load Acceptance, ISO 8528-5 Fuel Consumption G3 Prime Standby lb/hr kg/h lb/hr kg/h 25 % Power 0.0 0.0 63.9 29.0 50 % Power 0.0 0.0 119.0 54.0 75 % Power 0.0 0.0 169.8 77.0 100 % Power 0.0 0.0 207.2 94.0 Performance Curve: 6135HFG84_A Engine Performance Curves 6135 - Generator Sheet 4 - August 2013 HCI 434F/444F - Technical Data Sheet HCI434F/444F SPECIFICATIONS & OPTIONS STANDARDS Newage Stamford industrial generators meet the requirements of BS EN 60034 and the relevant section of other international standards such as BS5000, VDE 0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359. Other standards and certifications can be considered on request. VOLTAGE REGULATORS AS440 AVR - STANDARD With this self-excited system the main stator provides power via the Automatic Voltage Regulator (AVR) to the exciter stator. The high efficiency semi-conductors of the AVR ensure positive build-up from initial low levels of residual voltage. The exciter rotor output is fed to the main rotor through a three-phase full-wave bridge rectifier. The rectifier is protected by a surge suppressor against surges caused, for example, by short circuit or out-of-phase paralleling. The AS440 will support a range of electronic accessories, including a 'droop' Current Transformer (CT) to permit parallel operation with other ac generators. MX341 AVR This sophisticated AVR is incorporated into the Stamford Permanent Magnet Generator (PMG) control system. The PMG provides power via the AVR to the main exciter, giving a source of constant excitation power independent of generator output. The main exciter output is then fed to the main rotor, through a full wave bridge, protected by a surge suppressor. The AVR has in-built protection against sustained over-excitation, caused by internal or external faults. This de-excites the machine after a minimum of 5 seconds. An engine relief load acceptance feature can enable full load to be applied to the generator in a single step. If three-phase sensing is required with the PMG system the MX321 AVR must be used. We recommend three-phase sensing for applications with greatly unbalanced or highly non-linear loads. MX321 AVR The most sophisticated of all our AVRs combines all the features of the MX341 with, additionally, three-phase rms sensing, for improved regulation and performance. Over voltage protection is built-in and short circuit current level adjustments is an optional facility. WINDINGS & ELECTRICAL PERFORMANCE All generator stators are wound to 2/3 pitch. This eliminates triplen (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimum design for trouble-free supply of non-linear loads. The 2/3 pitch design avoids excessive neutral currents sometimes seen with higher winding pitches, when in parallel with the mains. A fully connected damper winding reduces oscillations during paralleling. This winding, with the 2/3 pitch and carefully selected pole and tooth designs, ensures very low waveform distortion. TERMINALS & TERMINAL BOX Standard generators are 3-phase reconnectable with 12 ends brought out to the terminals, which are mounted on a cover at the non-drive end of the generator. A sheet steel terminal box contains the AVR and provides ample space for the customers' wiring and gland arrangements. It has removable panels for easy access. SHAFT & KEYS All generator rotors are dynamically balanced to better than BS6861:Part 1 Grade 2.5 for minimum vibration in operation. Two bearing generators are balanced with a half key. INSULATION/IMPREGNATION The insulation system is class 'H'. All wound components are impregnated with materials and processes designed specifically to provide the high build required for static windings and the high mechanical strength required for rotating components. QUALITY ASSURANCE Generators are manufactured using production procedures having a quality assurance level to BS EN ISO 9001. The stated voltage regulation may not be maintained in the presence of certain radio transmitted signals. Any change in performance will fall within the limits of Criteria 'B' of EN 61000-6-2:2001. At no time will the steady-state voltage regulation exceed 2%. NB Continuous development of our products entitles us to change specification details without notice, therefore they must not be regarded as binding. Front cover drawing typical of product range. 2 HCI434F/444F WINDING 311 CONTROL SYSTEM A.V.R. VOLTAGE REGULATION SEPARATELY EXCITED BY P.M.G. MX321 MX341 ± 0.5 % ± 1.0 % With 4% ENGINE GOVERNING SUSTAINED SHORT CIRCUIT REFER TO SHORT CIRCUIT DECREMENT CURVES (page 7) CONTROL SYSTEM SELF EXCITED A.V.R. VOLTAGE REGULATION SUSTAINED SHORT CIRCUIT AS440 ± 1.0 % With 4% ENGINE GOVERNING WILL NOT SUSTAIN A SHORT CIRCUIT INSULATION SYSTEM CLASS H IP23 PROTECTION 0.8 RATED POWER FACTOR DOUBLE LAYER LAP STATOR WINDING WINDING PITCH TWO THIRDS WINDING LEADS 12 STATOR WDG. RESISTANCE 0.0073 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED ROTOR WDG. RESISTANCE 1.37 Ohms at 22°C EXCITER STATOR RESISTANCE 18 Ohms at 22°C EXCITER ROTOR RESISTANCE 0.068 Ohms PER PHASE AT 22°C R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0% 2250 Rev/Min MAXIMUM OVERSPEED BALL. 6317 (ISO) BEARING DRIVE END BALL. 6314 (ISO) BEARING NON-DRIVE END 1 BEARING 2 BEARING WEIGHT COMP. GENERATOR 1160 kg 1160 kg WEIGHT WOUND STATOR 535 kg 535 kg WEIGHT WOUND ROTOR 463 kg 440 kg 5.4292 kgm2 1230 kg 5.2304 kgm2 1230 kg 155 x 87 x 107(cm) 155 x 87 x 107(cm) WR² INERTIA SHIPPING WEIGHTS in a crate PACKING CRATE SIZE TELEPHONE INTERFERENCE 50 Hz 60 Hz THF<2% TIF<50 0.8 m³/sec 1700 cfm COOLING AIR 0.99 m³/sec 2100 cfm VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277 VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138 VOLTAGE SERIES DELTA kVA BASE RATING FOR REACTANCE VALUES Xd DIR. AXIS SYNCHRONOUS 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138 400 400 400 400 455 480 500 500 2.72 2.45 2.28 2.03 3.28 3.09 2.95 2.71 X'd DIR. AXIS TRANSIENT 0.18 0.16 0.15 0.13 0.18 0.17 0.16 0.15 X''d DIR. AXIS SUBTRANSIENT 0.13 0.12 0.11 0.10 0.13 0.12 0.12 0.11 Xq QUAD. AXIS REACTANCE 2.35 2.12 1.97 1.75 2.90 2.73 2.61 2.39 X''q QUAD. AXIS SUBTRANSIENT 0.31 0.28 0.26 0.23 0.43 0.41 0.39 0.35 XL LEAKAGE REACTANCE 0.06 0.05 0.05 0.04 0.07 0.07 0.06 0.06 X2 NEGATIVE SEQUENCE 0.23 0.20 0.19 0.17 0.29 0.27 0.26 0.24 0.08 X0 ZERO SEQUENCE REACTANCES ARE SATURATED T'd TRANSIENT TIME CONST. T''d SUB-TRANSTIME CONST. T'do O.C. FIELD TIME CONST. Ta ARMATURE TIME CONST. SHORT CIRCUIT RATIO 0.08 0.07 0.06 0.10 0.09 0.09 0.08 VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED 0.08s 0.019s 1.7s 0.018s 1/Xd 3 50 Hz HCI434F/444F Winding 311 THREE PHASE EFFICIENCY CURVES 4 60 Hz HCI434F/444F Winding 311 THREE PHASE EFFICIENCY CURVES 5 HCI434F/444F Winding 311 Locked Rotor Motor Starting Curve 50 Hz MX 346V 30 380V 400V 415V SX 440V 380V 400V 415V 440V 25 P E R C E N T T R A N S IE N T V O L T A G E D I P . 25 P E R C E N T T R A N S IE N T V O L T A G E D IP . 346V 30 20 20 15 15 10 10 5 5 0 0 0 200 400 600 800 1000 1200 1400 0 LOCKED ROTOR kVA 100 200 300 400 500 LOCKED ROTOR kVA 600 700 800 900 460V 480V 1000 60 Hz MX 380V 416V 440V 460V 480V 380V 30 25 25 20 20 P E R C E N T T R A N S IE N T V O L T A G E D IP . P E R C E N T T R A N S IE N T V O L T A G E D IP . 30 SX 15 10 5 416V 440V 15 10 5 0 0 0 200 400 600 800 1000 1200 1400 0 LOCKED ROTOR kVA 200 400 600 LOCKED ROTOR kVA 6 800 1000 1200 HCI434F Three-phase Short Circuit Decrement Curve. No-load Excitation at Rated Speed Based on star (wye) connection. 50 Hz 10000 SYMMETRICAL CURRE NT (Am ps) ASYMMETRICAL 1000 100 0.001 0.01 0.1 TIME (secs) 1 10 Sustained Short Circuit = 1,750 Amps 60 Hz 10000 SYMMETRICAL CURRE NT (Am ps) ASYMMETRICAL 1000 100 0.001 0.01 0.1 TIME (secs) 1 10 Sustained Short Circuit = 2,000 Amps Note 1 The following multiplication factors should be used to adjust the values from curve between time 0.001 seconds and the minimum current point in respect of nominal operating voltage : 50Hz Voltage 380v 400v 415v 440v Note 2 The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types of short circuit : 60Hz Factor X 1.00 X 1.05 X 1.09 X 1.16 Voltage 416v 440v 460v 480v 3-phase Factor X 1.00 X 1.06 X 1.10 X 1.15 The sustained current value is constant irrespective of voltage level 2-phase L-L 1-phase L-N Instantaneous x 1.00 x 0.87 x 1.30 Minimum x 1.00 x 1.80 x 3.20 Sustained x 1.00 x 1.50 x 2.50 Max. sustained duration 10 sec. 5 sec. 2 sec. All other times are unchanged Note 3 Curves are drawn for Star (Wye) connected machines. For other connection the following multipliers should be applied to current values as shown : Parallel Star = Curve current value X 2 7 HCI434F/444F Winding 311 / 0.8 Power Factor RATINGS Class - Temp Rise 50 Hz Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440 Parallel Star (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220 Series Delta (V) 220 230 240 254 220 230 240 254 220 230 240 254 220 230 240 254 kVA 370 370 370 370 400 400 400 400 415 430 430 430 425 450 440 440 kW 296 296 296 296 320 320 320 320 332 344 344 344 340 360 352 352 Efficiency (%) 93.5 93.8 93.9 94.0 93.2 93.4 93.6 93.8 92.9 93.0 93.2 93.5 92.8 92.8 93.1 93.4 kW Input 317 316 315 315 343 343 342 341 357 370 369 368 366 388 378 377 60 Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480 Hz Parallel Star (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240 Series Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277 kVA 420 445 465 465 455 480 500 500 485 515 535 535 500 530 550 550 kW 336 356 372 372 364 384 400 400 388 412 428 428 400 424 440 440 Efficiency (%) 93.7 93.8 93.8 94.0 93.4 93.4 93.5 93.7 93.1 93.1 93.1 93.4 92.9 92.9 93.0 93.2 380 397 396 390 411 428 427 417 443 460 458 431 456 473 472 kW Input 359 DIMENSIONS Barnack Road • Stamford • Lincolnshire • PE9 2NB Tel: 00 44 (0)1780 484000 • Fax: 00 44 (0)1780 484100 © 2006 TD_HCI4F.GB_10.06_04_GB ® DSEGenset DSE7310/20 ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment AUTO START & AUTO MAINS FAILURE CONTROL MODULES FEATURES ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment, including Electrical Business Equipment The DSE7310 is an Auto Start Control Module and the DSE7320 is an Auto Mains (Utility) Failure Control Module suitable for a wide variety of single, diesel or gas, gen-set applications. Monitoring an extensive number of engine parameters, the modules will display warnings, shutdown and engine status information on the back-lit LCD screen, illuminated LEDs, remote PC and via SMS text alerts (with external modem). The DSE7320 will also monitor the mains (utility) supply. The modules include USB, RS232 and RS485 ports as well as dedicated DSENet® terminals for system expansion. The extensive list of features includes enhanced event and performance monitoring, remote communications and dual mutual standby (DSE7310 only) to reduce engine wear. Both modules are compatible with electronic (CAN) and non-electronic (magnetic pick-up/alternator sensing) engines and offer an extensive number of flexible inputs, outputs and extensive engine protections so the system can be easily adapted to meet the most demanding industry requirements. The modules can be easily configured using the DSE Configuration Suite PC software. Selected front panel editing is also available. TEMPERATURE BS EN 60068-2-1 Ab/Ae Cold Test -30 oC BS EN 60068-2-2 Bb/Be Dry Heat +70 oC VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 oC @ 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 oC @ 93% RH 48 Hours SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 mS DEGREES OF PROTECTION PROVIDED BY ENCLOSURES BS EN 60529 IP65 - Front of module when installed into the control panel with the supplied sealing gasket. COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS MODEM MODBUS DSE2130 DSE2157 DSE2548 DSE2510/20 PC 8 232 ® DSENET EXPANSION 4 4 485 RS232 AND RS485 USB PORT CONFIGURABLE INPUTS DC OUTPUTS ANALOGUE SENDERS EMERGENCY STOP DC POWER SUPPLY 8-35V + DEUTZ ISUZU PERKINS CATERPILLAR MTU VOLVO CUMMINS SCANIA DSE7310/20 7 OTHER MAINS (UTILITY) SENSING DSE7320 ONLY N/C VOLT FREE OUTPUT N/O VOLT FREE OUTPUT CURRENT VOLTS 1ph 2ph 3ph N 1 1 CHARGE ALTERNATOR GENERATOR SENSING 1ph 2ph 3ph E N VOLTS D+ W/L FUEL & CRANK OUTPUTS (Flexible with CAN) ELECTRONIC ENGINES & MAGNETIC PICK-UP + 1ph 2ph 3ph N ISSUE 6 ® DSEGenset DSE7310/20 SPECIFICATION DC SUPPLY CONTINUOUS VOLTAGE RATING 8 V to 35 V Continuous AUTO START & AUTO MAINS FAILURE CONTROL MODULES FEATURES CRANKING DROPOUTS Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking. DSE7320 DSE7310 MAXIMUM OPERATING CURRENT 340 mA at 12 V, 160 mA at 24 V MAXIMUM STANDBY CURRENT 160 mA at 12 V, 80 mA at 24 V CHARGE FAIL/EXCITATION RANGE 0 V to 35 V MAINS (UTILITY) DSE7320 ONLY VOLTAGE RANGE 15 V - 333 V AC (L-N) FREQUENCY RANGE 3.5 Hz to 75 Hz KEY FEATURES • Reactive power protection • 4-Line back-lit LCD text display • Five key menu navigation • Front panel editing with PIN protection • Customisable status screens • Power save mode • Support for up to three remote display units • 9 configurable inputs • 8 configurable outputs • Flexible sender inputs • Configurable timers and alarms • 3 configurable maintenance alarms • Multiple date and time scheduler • Configurable event log (250) • Tier 4 CAN engine support • Integral PLC editor • Easy access diagnostic page • CAN and Magnetic Pick-up/Alt. sensing • Fuel usage monitor and low fuel alarms • Charge alternator failure alarm • Manual speed control (on compatible CAN engines) • Manual fuel pump control • Engine exerciser • “Protections disabled” feature • kW & kV Ar overload protection • Reverse power (kW & kV Ar) protection • LED and LCD alarm indication • Power monitoring (kW h, kV Ar, kV A h, kV Ar h) • Load switching (load shedding and dummy load outputs) • Automatic load transfer (DSE7320) • Unbalanced load protection • Independent Earth Fault trip • True dual mutual standby with load balancing timer (DSE7310 only) • USB connectivity • Backed up real time clock • Fully configurable via DSE Configuration Suite PC software • Configurable display languages • Remote SCADA monitoring via DSE Configuration Suite PC software • User selectable RS232 and RS485 communications • Configurable Gencomm pages • Advanced SMS messaging (additional external modem required) • Start & stop capability via SMS messaging RELATED MATERIALS TITLE DSE7310 Installation Instructions DSE7320 Installation Instructions DSE7200/7300 Quick Start Guide DSE7200/7300 Operator Manual DSE7200/7300 Configuration Suite PC Manual • Additional display screens to help with modem diagnostics • DSENet® expansion compatible KEY BENEFITS • 132 x 64 pixel ratio display for clarity • Real-time clock provides accurate event logging • Multiple date and time scheduler • Set maintenance periods can be configured to maintain optimum engine performance • Ethernet communications (via DSE860/865 modules), provides advanced remote monitoring at low cost • Modules can be integrated into building management systems (BMS) • Increased input and output expansion capability via DSENet® • Licence-free PC software • IP65 rating (with supplied gasket) offers increased resistance to water ingress • PLC editor allows user configurable functions to meet specific application requirements OUTPUTS OUTPUT A (FUEL) 15 A DC at supply voltage OUTPUT B (START) 15 A DC at supply voltage OUTPUTS C & D 8 A 250 V (Volt free) AUXILIARY OUTPUTS E,F,G,H 2 A DC at supply voltage GENERATOR VOLTAGE RANGE 15 V - 333 V AC (L-N) FREQUENCY RANGE 3.5 Hz to 75 Hz MAGNETIC PICK UP VOLTAGE RANGE +/- 0.5 V to 70 V FREQUENCY RANGE 10,000 Hz (max) DIMENSIONS OVERALL 240 mm x 181 mm x 42 mm 9.4” x 7.1” x 1.6” PANEL CUT-OUT 220 mm x 160 mm 8.7” x 6.3” MAXIMUM PANEL THICKNESS 8 mm 0.3” PART NO’S 053-028 053-029 057-101 057-074 057-077 DEEP SEA ELECTRONICS PLC UK Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com DEEP SEA ELECTRONICS INC USA 3230 Williams Avenue, Rockford, IL 61101-2668 USA TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708 EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change the details shown on this data sheet without prior notice. The contents are intended for guidance only. Registered in England & Wales No.01319649 VAT No.316923457 055-051/10/11 (10) US ® DSEGenset DSE2548 DSENET OUTPUT EXPANSION MODULE ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment ® ELECTRICAL SAFETY BS EN 60950 Safety of Information Technology Equipment, including Electrical Business Equipment The DSE2548 is an LED expansion module that can be used with all DSENet® compatible control modules. The module has been designed to display a maximum of eight individual LED indications up to a maximum distance of 1 KM (0.6miles). The DSE2548 includes individual LEDs for each channel and a ‘Power On’ LED that flashes when the link with the host controller is lost. TEMPERATURE BS EN 60068-2-1 Ab/Ae Cold Test -30 oC BS EN 60068-2-2 Bb/Be Dry Heat +70 oC VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn The DSE2548 is presented in a vertical enclosure. It includes an alarm sounder that is triggered when the host controller detects an alarm condition. The alarm can be muted directly from the DSE2548 using the front push button. HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 oC @ 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 oC @ 93% RH 48 Hours SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 mS DEGREES OF PROTECTION PROVIDED BY ENCLOSURES BS EN 60529 IP65 - Front of module when installed into the control panel with the supplied sealing gasket. COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS HOST MODULE (1) 1 DSENET® EXPANSION DC POWER SUPPLY 8-35V COMPATIBLE WITH DSE7310/20, DSE8610/60/80 & DSE8710/60 DSE2548 DSENET® HOST MODULE 7 2157 2130 2510/20 2548 OTHER CONFIGURABLE LEDS AUDIBLE ALARM 8 ISSUE 3 ® DSEGenset DSE2548 DSENET OUTPUT EXPANSION MODULE ® SPECIFICATION DC SUPPLY CONTINUOUS VOLTAGE RATING 8 V to 35 V Continuous CRANKING DROPOUTS Able to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries. LEDs and backlight will not be maintained during cranking. MAXIMUM OPERATING CURRENT 112 mA at 12 V, 53 mA at 24 V MAXIMUM STANDBY CURRENT 74 mA at 12 V, 35 mA at 24 V DIMENSIONS OVERALL 180 mm x 116 mm x 42.7 mm 7.07” x 4.57” x 1.68” PANEL CUT-OUT 154 mm x 98 mm 6.06” x 3.86” MAXIMUM PANEL THICKNESS 8 mm 0.3” KEY FEATURES • Eight configurable LEDs • Works up to 1 KM (0.6 miles) from the host controller • 10 modules can be linked together to one host controller ID SWITCH The rotary ID switch is used to select the address of the DSE2548 expansion module, as the host control module is capable of giving instructions to a number of DSE2548 expansion modules at the same time. RELATED MATERIALS TITLE DSE2548 Installation Instructions DSE2548 Operator Manual PART NO’S 053-032 057-084 DEEP SEA ELECTRONICS PLC UK Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com DEEP SEA ELECTRONICS INC USA 3230 Williams Avenue, Rockford, IL 61101-2668 USA TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708 EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change the details shown on this data sheet without prior notice. The contents are intended for guidance only. Registered in England & Wales No.01319649 VAT No.316923457 055-062/10/10 (3) ® DSEPower DSE9470, DSE9472, DSE9480 & DSE9481 ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4 EMC Generic Emission Standard for the Industrial Environment MK ll INTELLIGENT BATTERY CHARGERS 5 AMP & 10 AMP, 12 VOLT & 24 VOLT OPTIONS OPERATING TEMPERATURE RANGE BS EN 60068-2-1 Ab/Ae Cold Test -30 oC BS EN 60068-2-2 Bb/Be Dry Heat +80 oC * Refer to de-rating curve in the DSE9000 Operator Manual FEATURES The DSE9400 series is a range of intelligent battery chargers that can be programmed for different charging curves to maximise the life of the battery. The chargers do not include any moving parts to give added durability and reliability. They will also continue to operate during engine running. The DSE9400 series of intelligent battery chargers are programmed using the user-friendly DSE Configuration Suite PC software. Multiple modules can be linked together to provide a larger current output. VIBRATION BS EN 60068-2-6 Ten sweeps in each of three major axes 5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn HUMIDITY BS EN 60068-2-30 Db Damp Heat Cyclic 20/55 oC @ 95% RH 48 Hours BS EN 60068-2-78 Cab Damp Heat Static 40 oC @ 93% RH 48 Hours The chargers can be either mounted via DIN rail or to the chassis, using the fixing holes that are built into the case. The charger’s stylish design includes three coloured LEDs to indicate charging status and fault conditions. SHOCK BS EN 60068-2-27 Three shocks in each of three major axes 15 gn in 11 mS COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF BATTERY CHARGER APPLICATIONS MODBUS PC 1ph N CHARGE OUTPUT USB PORT RS485 AC POWER SUPPLY VOLT FREE CHANGE OVER FAULT OUTPUT CONFIGURABLE INPUT COMPATIBLE WITH ALL DSE MODULES DSE9470, DSE9472, DSE9480 & DSE9481 7 OTHER TEMPERATURE SENSOR PT1000 ONLY 1 1 ISSUE 1 ® DSEPower DSE9470, DSE9472, DSE9480 & DSE9481 SPECIFICATION MKll INTELLIGENT BATTERY CHARGERS AC SUPPLY VOLTAGE RANGE 90 V to 305 V (L-N) 5 AMP & 10 AMP, 12 VOLT & 24 VOLT OPTIONS FREQUENCY RANGE 48 Hz to 64 Hz (L-N) FEATURES DC OUTPUT DSE9470 OUTPUT 10 A DC at 24 V DC DSE9472 OUTPUT 5 A DC at 24 V DC DSE9480 OUTPUT 10 A DC at 12 V DC DSE9481 OUTPUT 5 A DC at 12 V DC RIPPLE AND NOISE <1% EFFICIENCY >86% REGULATION LINE <0.5% LOAD 2% TEMPERATURE SENSOR INPUT PT1000 ADVANCED FEATURES • Intelligent two, three and four stage charging profiles • Configurable to suit 12V and 24V applications • Adjustable current limit (Max 10A) • Can be used as a battery charger, power supply or both at the same time • Automatic or manual boost and storage charge functions to help maintain battery condition • Digital microprocessor technology • Temperature compensation for battery charging • Low output ripple and superb line regulation • Three LEDs indication Full Protection • AC input under voltage • AC input over voltage • Battery charger output over voltage • Battery charger output over current • Output short circuit and inversion polarity with auto recovery • Automatic power de-rating at high ambient temperatures. • Optional battery temperature compensation using PT1000 temperature sensor with over temperature protection Automatic Boost Mode • Boosts and equalises cell charge improving battery performance and life Power Save Mode • Once the battery is fully charged the chargers switch to ecopower to save energy Communication • Can be integrated in to external systems through MODBUS RTU using RS485 • Fully configurable via DSE Configuration Suite PC Software RELATED MATERIALS TITLE DSE9400 Series Configuration Suite PC Software Manual DSE Configuration Suite Installation & Operator Manual DSE9000 Series Installation Instructions DSE9000 Series Operator Manual DEEP SEA ELECTRONICS PLC UK Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change the details shown on this data sheet without prior notice. The contents are intended for guidance only. • External remote LCD option DSE2541 KEY BENEFITS • Fully flexible to maximise the life of the battery • Suitable for a wide range of battery types • Switched mode design • Minimum 86% efficiency throughout full operating range • No external intervention for boost mode • Multiple chargers can be linked together to provide larger current output • Can be permenantly connected to battery and AC supply. No need to disconnect through high load conditions such as cranking or when the engine is running. PROTECTIONS Short Circuit DC Over Voltage DC Over Current Reverse Polarity Over Temperature AC Under & Over Voltage CHARGE FAILURE RELAY 3 A at 30 V DC volt free relay DIMENSIONS OVERALL 70 mm x 200 mm x 130 mm 2.7” x 7.9” x 5.1” WEIGHT 0.75 kg OPERATING TEMPERATURE RANGE -30 oC to +55 oC STORAGE TEMPERATURE RANGE -30 oC to +70 oC PART NO’S 057-159 057-151 057-049 057-085 DEEP SEA ELECTRONICS INC USA 3230 Williams Avenue, Rockford, IL 61101-2668 USA TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708 EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com Registered in England & Wales No.01319649 VAT No.316923457 055-158/03/13 (2) US 6 5 4 3 2 1 120 [4.724] 2218 [87.323] 2238 [88.11] D 150 [5.906] 1300 [51.181] 1300 [51.181] 600 [23.622] 450 [17.717] 2900 [114.173] 500 [19.685] 1100 [43.307] 1730 [68.11] 600 [23.622] 1200 [47.244] 14x 18x25 1820 [71.653] 1900 [74.803] 5200 [204.724] C 5225.4 [205.724] For Breaker panel cable outlet 1088 [42.835] 411 [16.181] 414 [16.299] B COPYRIGHT RESERVED C THE DESIGN AND DETAIL OF THIS DRAWING IS THE PROPERTY OF Aksa Power Generation (China) Co. Ltd. AND MUST BE RETURNED ON DEMAND. IT IS ISSUED ON THE STRICT CONDITION THAT WITHOUT WRITTEN PERMISSION IT MUST NOT BE REPRODUCED. COPIED OR COMMUNICATED TO ANY THIRD PARTY NOR BE USED FOR ANY PURPOSE OTHER THAN THAT STATED IN THE PARTICULAR ENQUIRY.ORDER OR CONTRACT WITH WHICH IT IS ISSUED THE RESERVATION OF COPYRIGHT IN THIS DOCUMENT EXTENDS FROM EACH DATE APPEARING THERE ON AND IN RESRECT OF THE SUBJECT MATTER AS IT APPEARED AT THE RELEVANT DATE. 1:50 2015 DATE NAME 18/06 EVAN CONTROLED BY 18/06 APPROVED BY 18/06 APD-ULJ300 CANOPY ASSEMBLY DRAWING HAKEA A TOTO APD-ULJ300CANOPY(Lev1) ENGINEERING A3 PAGE DATE 6 5 4 3 00 NAME 2 1 ASCO Series 300 Service Entrance Power Transfer Switch The ASCO Service Entrance Power Transfer Switch combines automatic power switching with the necessary disconnecting, grounding, and bonding required for use as service entrance equipment. The power transfer switch meets all National Electrical Code requirements for service entrance use. Product Features: • Suitable for use as service entrance equipment. Listed to UL 891 (standard for switchboards) for 600 - 3000 amps, sizes and UL 1008 (standard for panel-boards) for 70 - 400 amps. • Automatic Transfer Switch is listed to UL 1008 for total system loads • Sizes available from 70 - 3000 amps, 600 VAC, 50 or 60 Hz, single or three phase • Silver plated copper ground and neutral bus with solderless screw type terminals • Ground fault trip protection provided on sizes 1000 amps and above • Available with solid or switched neutral ASCO Series 300 SE Rated 800 amperes Type 1 enclosure ASCO Series 300 SE Rated 200 amperes in Type 3R enclosure ASCO Series 300SE products use two types of construction. 70 - 400 Amp Construction 600 - 3000 Amp Construction Products 400 amperes or less, utilize a single enclosure including a service (utility source) disconnect circuit breaker, as well as the power transfer switch, grounding and bonding provisions. Products 600 amperes and above, utilize a multi-section switchboard construction including a service equipment section containing the service (utility source) disconnect circuit breaker, grounding, and bonding provisions. A second section contains the power transfer switch. AS To order an ASCO Series 300SE Power Transfer Switch, complete the following catalog number: J 03AUS + B + Product Type Frame + Neutral Code 3 0600 + Phase Poles + N Amperes Continuous Rating 2 2 0070, 0100, poles, 0150, 0200, 1Ø 02255, 02505, E 260 - 400 Amp 03NUS Non Automatic 0400, 0600, B1 Switched 3 3 J 150 - 6008 Amp 0800, 1000, 3ADUS Automatic Delayed poles, 1200, 1600, Neutral Transition 3Ø H 800 - 1200 Amp 2000 2500, 3000 3NDUS Non Automatic G 1600 - 3000 Amp Delayed Transition D 70 - 225 Amp 03AUS Automatic A Solid Neutral A2 B2 C D E F H J K L M N Q R Notes: 1. Specify neutral code “C” for 250 and 400 amperes for 3AUS, 3NUS only. 2. 115-120 volt available 150-400 amperes for 3AUS, 3NUS only. 3. Available for 70-1000 amperes, use type 3R for 1200-3000 ampere applications. 4. A solid neutral is provided as standard. 5. 200, 225 ampere rated switches suitable for use with copper cable only. GX + Voltage Code 115 120 208 220 230 240 380 400 415 440 460 480 575 600 C + Controller Code Enclosure G No Accessories C M GX With Accessories N P Q R S Type 1 (Standard) Type 3R Secure Double Door Type 43 Secure Double Door Type 4X3, 6 Secure Double Door 316 SS Type 123 Secure Double Door Type 3RX3, 6, 7 Secure Double Door Type 4X3 Secure Double Door 304 SS Refer to paragraph 310.15 of the NEC for additional information. 6. Type 316 stainless steel is the standard. It provides an improved reduction in corrosion of salt and some chemicals. It is the preferred choice for marine environments. 7. Available only on switches rated 1200, 2000, 2600 and 3000 amperes. 8. J 150-400 ampere for Series 3ADUS/3NDUS only. ASCO Series 300SE Power Transfer Switch Dimensions and Shipping Weights UL Type 1 Enclosure4 Switch Rating Amps 70, 100 ,150, 200, 225 250, 400 150, 200, 225, 260, 400 Series 3ADUS/3NDUS Only 6001 8001 10001, 12001 16001, 20001 25001, 30001 Notes: UL Type 3R Enclosure4 Phase Neutral Code Poles 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3 A B A B A C A C A B A B A B A B A B A B A B A B A B A B Dimensions, In. (mm) Width Height Depth 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 13 (330) 13 (330) 13 (330) 13 (330) 13 (330) 13 (330) 13 (330) 13 (330) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 72 (1829) 72 (1829) 400 (185) 408 (188) 408 (188) 420 (193) 400 (185) 408 (188) 408 (188) 420 (193) 860 (396) 870 (401) 870 (401) 880 (405) 860 (396) 870 (401) 870 (401) 880 (405) 1460 (673) 1470 (677) 1470 (677) 1480 (682) 1460 (673) 1470 (677) 1470 (677) 1480 (682) 1684 (781) 1716 (796) 2172 (1008) 2203 (1022) 1. Unit is designed for top and bottom cable entry for all services and load. 2. Enclosures for 600 – 3000 amps are freestanding. 3. A space heater accessory 44G is required with all service entrance (Type 3R) switches to help reduce Series 300SE External Power Connections Sizes UL-Listed Solderless Screw-Type Terminals Switch Rating 70, 100, 150, 200*, 225* 250, 400 600 800, 1000, 1200 1600, 2000 2500 3000 250, 400 150, 200, 225, 260, 400 Series 3ADUS/3NDUS Only 6001 8001 10001, 12001 16001, 20001 25001, 30001 Emerson Network Power ASCO Power Technologies 50 Hanover Road, Florham Park, NJ, 07932 EmersonNetworkPower.com/ASCO customercare@asco.com 1-800-800-ASCO (2726) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 36 (914) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 38 (965) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 48 (1219) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 91 (2311) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 16 (406) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 28 (711) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 48 (1218) 72 (1829) 72 (1829) Approx. Shipping Weight Lb. (kg) 500 (232) 520 (241) 520 (241) 530 (246) 500 (232) 520 (241) 520 (241) 530 (246) 1170 (543) 1180 (548) 1180 (548) 1200 (557) 1170 (543) 1180 (548) 1180 (548) 1200 (557) 1530 (710) 1540 (715) 1540 (715) 1560 (724) 1530 (710) 1540 (715) 1540 (715) 1560 (724) 2180 (1012) 2200 (1021) 2815 (1306) 2865 (1329) Extended Warranties for Series 300SE Transfer Switches (3AUS/3NUS/3ADUS/3NDUS) Description 1 Year Extension (Total of 3 Years) 2 Year Extension (Total of 4 Years) 3 Year Extension (Total of 5 Years) One #14 to 4/0 AWG (unless switched neutral configuration is specified) and terminal lugs. 2. 200 and 225 ampere rated switches for use with copper cable only. Refer to paragraph 310.15 of the NEC for all additional information. 3. Use wire rated 75 degrees minimum for all power connections. 4. Refer to the outline drawing for maximum power cable connections for circuit breaker. A B A B A C A C A B A B A B A B A B A B A B A B A B A B Dimensions, In. (mm) Height Depth Width condensation and protect the circuit breaker. It is recommended when environmental enclosures (Type 4, 12) are ordered for installation outdoors. See Optional Accessories page for space heater options (acc. 44G). 4. Dimensional data is approximate and subject to change. Certified dimensions available upon request. (Unless Specified Copper Only) Notes: 1. All Series 300SE switches are furnished with a solid neutral plate 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 2 2 3 3 3 3 3 3 70, 100 ,150, 200, 225 Ranges of AL-CU Wire Sizes Two 1/0 AWG to 250 MCM or One #4 AWG to 600 MCM Two 1/0 AWG to 600 MCM Four 1/0 to 600 MCM Six 1/0 to 600 MCM Twelve 3/0 to 600 MCM Twelve 3/0 to 600 MCM Phase Neutral Code Poles Switch Rating Amps Approx. Shipping Weight Lb. (kg) Notes: 1. Standard warranty is (24) months, 2 years from date of shipment, extended warranty is in addition to the two years, for a total of 3, 4 or 5 years, except where the warranty period for the circuit breaker shall be limited to 24 months from date of shipment from ASCO. 2. Refer to Publication 3223 for warranty terms and conditions. Series 300SE AIC Breaker Rating1 Switch Rating AIC Rating (KA) Voltage 70, 100, 150, 200, 225 250, 400 150, 200, 225, 250, 400 Series 3ADUS/3NDUS Only 600 800, 1000,1200, 1600, 2000 2500, 3000 35,000 35,000 480 480 50,000 480 65,000 100,000 480 480 Notes: 1. Refer to Series 300 Publication 1195 for switch ratings. Emerson, Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©May, 2015 Emerson Electric Co. Publication 2007 ST. TAMMANY PARISH PATRICIA P. BRISTER PARISH PRESIDENT March 14, 2016 Please find the following addendum to the below mentioned BID. Addendum No.: 1 Bid#: 404-40-16-11-2 Project Name: Statewide Generator Program Bid Due Date: Tuesday, March 28, 2016 GENERAL INFORMATION: 1. Add Site Map- Harrison (Attached) 2. Add Site Map- Lyons (Attached) 3. The Bid opening date has been pushed to Tuesday, March 28, 2016. The last day to submit written inquiries is Thursday, March 17, 2016 at 2:00 PM. The last day to issue an addendum is Wednesday, March 23, 2016 at 2:00 PM. Time and location remain the same. QUESTIONS & ANSWERS: Question #1: Please provide site and electrical drawings for the Statewide Generator Program #404-40-16-11-2. Answer #1: Please see Attachment No. 1 & 2. ATTACHMENTS: 1. Site Map- Harrison.pdf 2. Site Map- Lyons.pdf << End of Addendum #1>> PROCUREMENT DEPARTMENT P.O. BOX 628 | COVINGTON, LOUISIANA | 70434 | PROCUREMENT@STPGOV.ORG | 985-898-2520 WWW.STPGOV.ORG