Industrial Relays Miniature Contactors Comat products comply with different international standards and are certified accordingly. Miniature Contactors Recommended application 63A 40A 25A 20A 10A 6A & & 10 mA 5 mA 1mA 2 3 +1 RIC20 SOC-6 4 twin contacts RIC-AUX SOC-2 RIC25 RIC40 RIC63 1 L1 13 3 L2 23 5 L3 33 Additional auxiliary Snap-on contacts 43 1 2 T1 3 13 MAX MIN Continuous terminal No. ➞ Designation according to DIN/EN 50011 ➞ 53 NO 83 NO 5 14 63 NO 71NC 81NC 51NC 61NC 71NC 81NC 10A 400Va 4 T2 24 54 NO 44 34 6 T3 14 NO 64 NO 74 NO SU-440M O 54 NO 84 NO 64 NO 72 NC SU-422M SS-1BM / UC12-48 VU O 82 NC 52 NC 62 NC 72 NC 01 O A1 SU-404M 0µ47 150 82 NC A2 SU-440M SOC- 6 -1a 4000V 4000V Test voltage: Tamb. operation/ storage: -20..+60/ - 40..+85°C 73 NO 01 50/60 Hz ON 20A 400 Va • All contacts with twin interruption • Manual operation • Mechanical status display 63 NO SOC-6-1a/AC230V 01 E0414 01 53 NO 3-/4-pole Miniature Contactor RC Modules A1 13 NO 01 DIN SOC-6 Miniature Contactor Miniature Contactor SU-422M SS-1... SU-404M Universal Miniature Contactor Additional auxiliary contact block Additional auxiliary contact block Additional auxiliary contact block with 3 main contacts 20A and 1 auxiliary contact 10A (signal twin contact). Contact opening > 3mm and test voltage 4000V. Specially suitable for “safely separation” in low voltage circuits. 4 NO contacts. Snap-on to miniature contactor SOC-6. Expands the SOC-6 up to a total of 8 NO contacts. 2 NO + 2 NC contacts. Snap-on to miniature contactor SOC-6. Expands the SOC-6 up to a total of 6 NO and 2 NC contacts. 4 NC contacts. Snap-on to miniature contactor SOC-6. Expands the SOC-6 up to a total of 4 NO and 4 NC contacts. 20 A // 10 A 400 V A 10 A 400 V A 10 A 400V A 10 A 400V A 10mA 24V // 1mA 6V 10mA 24V 10mA 24V 10mA 24V 1 3 5 13 A1+ L1 L2 L3 NO 13 23 33 43 53 63 73 83 53 63 71 81 51 61 71 RC Modul to limit overvoltage. Universal version (UC...VU) for AC and DC coils. Snap-on directly onto miniature contactor SOC-6. 81 NO NO NO NO NO NO NC NC NC NC NC NC NO NO NO NO NO NO NC NC NC NC NC NC Connection lay out (top/bottom) 14 24 34 44 T1 T2 T3 NO 2 4 6 14 A2 Data at Tamb. =20°C / 40°C Main contacts // Auxiliary contact Contact material Switching power AC1 Switching power AC 3/4 Switching current AC15 Switching power DC1 Switching power DC13 Making-/Breaking capacity Mechanical switching cycles AgNi 11kW 400V // 4kW 400V 4kW 9A 400V // – 1,9A 400V // 1,5A 400V ...300W 0,3A 220V // 0,1A 220V 90A / 70A eff 20x106 Operation voltage AC 50 Hz / DC Power consumption Typical make/release time 0,8...1,2UN 4,2VA/3W 20ms/15ms AC DC 10% 64 74 84 AgNi 7kW 400V – 1,9A 400V ...300W 0,3A 220V >30A 10x106 24, 230 SOC-6-1a / AC ..... V 50Hz Interlocking unit 54 54 64 72 82 AgNi 7kW 400 V – 1,9A 400V ...300W 0,3A 220V >30A 10x106 SU-440M 52 62 72 AgNi 7kW 400V – 1,9A 400V ...300W 0,3A 220V >30A 10x106 SU-422M SU-404M A1 A2 82 Current consumption: at AC 24V : 8mA at DC24V : 4mA at AC230V : 12mA at DC220V: 2,5mA Release time SOC-6 with RC module 45ms SS-1HM/UC110-240V SS-1BM / UC12-48 V 24 SOC-6-1a / DC ..... V SR-6 mechanically prevents the simultaneous engagement of two parallel working SOC-6. Type: 01 SR-6 Interlock Unit O O Arrangement Ordering example 23 5 L3 33 •Auxiliary contact block 13 NO 43 SS-1... SOC-6 (2NO + 2NC contacts) SU-422M RC module SS-1H/UC110-240V Interlocking unit SR-6 2 T1 14 4 T2 24 34 6 T3 35 44 44 14 NO SU-4... SS-1... SR-6 SR-6 A1 TS35 3 L2 58 13 50 1 L1 45,4 Miniature contactor SOC-6-1a/AC230V SU-4... SOC-6 A2 6 3 53 57 1 1 26,2 1 Innstallation Contactor SOC-2-1a DIN SOC-2 Miniature Contactor Cover sealed 3 5 13 1 3 13 SOC-2-1a /AC230VA 4 6 AC1 20A 400VIEC/EN 13KW 02 60947-4 AC3 2,2kW 400V A1 EN 60947-4; IEC1095; VDE 0660 A2 14 AC1 20A 400V/13kW AC3 2,2kW/400V O I A1 1 L1 2 2 3 50Hz IEC/EN 60947-4 02 AC1 20A 400V/13kW AC3 2,2kW/400V 50Hz T1 2 5 SOC-2-1a/AC230VA 50Hz SOC-2-1a /AC230VA 1 L2 5 4 4 I L3 T2 13 O A1 A2 T3 6 14 6 A214 02 SOC-2-1a 3- + 1-pol. Miniature Contactor • All contacts with twin interruption • Manual operation • Mechanical status display Test voltage: 4000V 4000V Tamb. operation/storage: -20..+55/ - 30..+80°C MAX MIN Installation Contactor High power relay up to 3x20A 400V and 1 auxiliary twin contact 6A. For installation mounting with cover conform DIN 43880. The cover can be sealed. For general applications and motors up to 2,2kW. Suitable for pilot control signals. 20 A // 6 A 400 V A 10mA 24V // 1mA 6V Continuous terminal No. ➞ A1 1 3 5 13 L1 L2 L3 NO 13 23 33 43 Designation according to DIN/EN 50011 ➞ Connection lay out (top/bottom) 14 24 34 44 T1 T2 T3 NO 2 4 6 14 A2 Data at Tamb. =20°C / 40°C Main contacts // Auxiliary contact Contact material Switching power AC1 Switching power AC3 /4 Switching current DC1 Inrush current AgNi 13kW 400V 2,2kW 400V 20A 24V / 2A 110V 100A / 2,5ms Switching current Switching current DC1 Mechanical life time 6A 400V 6A 24V / 0,5A 220V > 3 x 10 6 Coil voltage Coil power Typical make / release time 0,8 - 1,2 U N 32W 20ms /1,5 W < 20ms / < 20ms Installation contactor SOC-2-1a/AC230V Bestellbeispiel TS35 Ordering example 24, 230 SOC-2-1a/AC.....V 62,5 50Hz 50 AC SOC-2 Spare parts Cover sealed SOC-2COV 4,1 4,5 4,75 35 45 1 50.5 8 DIN RIC Miniature Contactor Contactor 20 A Contactor 25 A Contactor 40 A 4NO or 4NC or 2NO/2NC 2NO or 2NC or 1NO/1NC Contactor 63 A AUX Block 2NO or 2NC or 1NO/1NC 4NO or 2NO/2NC 4NO or 4NC or 2NO/2NC SE! TS35 NO NOI AC/DC Istallation Contactors No noise! • All contacts doublemake/ doublebrake • Mechanical status display Test voltage: 4kV/3 Tamb. operation/storage: -20..+55/ - 30..+ 80°C MAX MIN RIC 20 RIC 25 RIC 40 Contactor 20 A Contactor 25 A Contactor 40 A Contactor 63 A Auxilary Contactor with 2NO or 2NC or 1NO+1NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional. Contactor with 4NO or 4NC or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional. Contactor with 4NO or 4NC or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional. Contactor with 4NO or 2NO+2NC contacts. UC (AC/DC) versions are noise free and do not need external freewheeling circuits. No coil inrush overcurrent. Sealing cover optional. Contactblock with 2NO or 2NC or 1NO+1NC contacts. For signalling and control applications up to 6 A with crown twin contacts. For all RIC contactors. 20 A 400 V A 25 A 400 V A 40 A 400 V A 63 A 400 V A 6 A 400 V A 10mA 24V 10mA 24V 10mA 24V 10mA 24V 5mA 24V 1 A1 3 1 3 A1 5 7 1 RIC 63 3 A1 5 7 1 RIC-AUX 3 A1 5 7 51 61 Connection lay out (top/bottom) 2 A2 4 2 4 A2 6 8 2 4 A2 6 8 2 4 A2 6 8 52 62 1 A1 R1 1 R1 A1 R3 3 1 R1 A1 R3 3 1 R1 A1 R3 3 51 61 4 2 4 2 R2 A2 R4 4 52 62 2 A2 R2 2 R2 A2 R4 R2 A2 R4 R1 A1 R3 R1 R3 A1 R5 R7 R1 R3 A1 R5 R7 51 61 R2 A2 R4 R2 R4 A2 R6 R8 R2 R4 A2 R6 R8 52 62 Data at Tamb =20°C Contact material Switching current I TH Switching voltage Switching power AC3 Switching power AC1/AC7a Op Frequenz max. cycle/hr Electrical life cycles AC1 AgNi 20A 400V 1,3kW/230V 4kW/230V 600 2x105 AgNi 25A 400V 2,2kW/400V 16kW/400V 600 2x10 5 AgSnO2 40A 400V 5,5kW/400V 26kW/400V 120 1x10 5 AgSnO2 63A 400V 8,5kW/230V 40kW/400V 120 1x105 AgNi 6A 400V – – 600 2x10 5 Coil voltage range Power consumption Operate / release time typ. 0,85 - 1,1 U N 2,5W 20ms // 20ms 0,85 - 1,1 U N 3W 10 ms // 50ms 0,85 - 1,1 U N 5W 20 ms // 35ms 0,85 - 1,1 U N 5W 20 ms // 35ms – – – // – UC A 50/60Hz / D UC A 50/60 Hz / D UC A 50/60 Hz / D 24, 230 RIC25-400/UC ..... V 24, 230 RIC40-400/UC ..... V 24, 230 RIC63-400/UC ..... V RIC-AUX20 24, 230 RIC20-110/UC ..... V 24, 230 RIC25-220/UC ..... V 24, 230 RIC40-220/UC ..... V 24, 230 RIC63-220/UC ..... V RIC-AUX11 24, 230 RIC20-020/UC ..... V 24, 230 RIC25-040/UC ..... V 24, 230 RIC40-040/UC ..... V RIC-AUX02 RIC25-63 RIC 40 RIC 63 RIC 25 RIC-AUX Aux block RIC-AUX20 Sealing cover RIC-SEAL20 45 RIC20 Installation contactor RIC25-400/UC230V *Option Sealing cover Type: RIC-SEAL 20 RIC-SEAL 25 RIC-SEAL40-63 TS 35 Ordering example 85 RIC20 24, 230 RIC20-200/UC ..... V 1.5* 17,5 35 54.5 8 5 44 ( 45.5* ) 16.5 ! Kühn Controls AG Notes: You want more information about this product, please call us: tel: +49 (0)7082-940000 or send us a fax: +49 (0)7082-940001, or email: sales@kuehn-controls.de or visit our Website: www.kuehn-controls.de