CR305X, CH385X Auxiliary Contact Kits for Field Installation r aoo

advertisement
GE NEMA Rated Full Voltage Starters
CR305X, CH385X Auxiliary Contact Kits for Field Installation
r aoo-Line Auxiliary contact Kits
on Magnetic Contactors and Starters
NEMA Sizes 0-7
starters; and, in conjunction with a standard reversing starter and
plugging switch, to plug-stop motors. Auxiliary contacts can be
added to all across-the-line magnetic starters and contactors,
combination magnetic starters, reversing and multi-speed
controllers.
Each auxiliary contact is rated 10 Amperes ac, resistive load,
NEMA "A600," and is suitable for either right or left side mounting.
An insulating shield is also provided between each auxiliary
contact unit and the starter. Auxiliary contacts are furnished in the
basic block design or as an adder block.
Basic block
Adder block
Application
Auxiliary contacts can add to the versatility of magnetic contactors
and starters by providing additional control circuits to do a variety
of jobs without adding to the width of the starter.
Kits make it easy to add contacts to control accessory equipment
such as indicating lights; to control sequencing of other motor
Each contact is marked NO or NC on the block and is not
convertible.
Logic reed contacts suitable for low energy level circuits are also
available. These are designed for applications on low-voltage
control circuits (24 Volts and below), such as inputs to computers
and programmable controllers.
Ordering Directions
Order by quantity and complete Catalog Number. Example: Three
CR305X300A at $36.00 each, GO-10G.
Auxiliary Contact Kits for 300-Line Size 0-6 Contactors and Starters
(Also suitable for 200-Line)
Basic Blocks
>
NEMA Size
Contactor
or Starter
Adder Blocks ©
1 NO-1 NC
Contacts
1 NO Contact
1 NC Contact
Catalog Number
Catalog Number
List
Price,
GO-10G
Catalog Number
0,1
2
CR305X100A
CR305X200A
CR305X100B
CR305X200B
$ 36.00
36.00
CR305X100C
CR305X200C
3
4
CR305X300A
CR305X300A
CR305X300B
CR305X300B
36.00
36.00
5,6
CR305X500A
CR305X500B
36.00
List
Price,
GO-10G
1 NO Contact
1 NC Contact
Catalog Number
Catalog Number
List
Price,
GO-10G
$ 48.00
48.00
CR305X100D
CR305X100D
CR305X100E
CR305X100E
$36.00
36.00
CR305X300C
CR305X300C
48.00
48.00
CR305X100D
CR305X100D
CR305X100E
CR305X100E
36.00
36.00
CR305X500C
48.00
CR305X100D
CR305X100E
36.00
Auxiliary Contact Kits for Size 7-9 Contactors and Starters
7
CR385X600A
CR385X600B
198.00
CR385X600C
396.00
CR305X100D
CR305X100E
36.00
8-9
CR385X800A
CR385X800B
198.00
CR385X800C
396.00
CR305X100D
CR305X100E
36.00
Note: Four extra auxiliary contacts (not blocks) is the maximum that can
be added to either a NEMA size 0 or 1 contactor/starter while five is
the maximum extra auxiliary contacts that can be added to NEMA
Size 2 through 6 devices.
Logic Reed Switch Auxiliary Contacts
Contact Arrangement
NO
NC
Catalog
Number
1
0
1
1
CR305X100RA
CR305X100RB
CR305X100RC
$45.00
45.00
72.00
CR305X200RA
CR305X200RB
CR305X200RC
45.00
45.00
72.00
NEMA Size
00,0, 1
0
1
List Price,
GO-10G
1
0
0
2
1
0
3,4
0
1
1
1
CR305X300RA
CR305X300RB
CR305X300RC
45.00
45.00
72.00
1
0
5,6
0
CR305X500RA
CR305X500RB
CR305X500RC
45.00
45.00
72.00
1
1
References:
1
1
1
1
Contact Ratings
High Fidelity Contact Basic Block
120 Vac maximum .15 A maximum, 8 VA maximum resistive.
30 Vdc maximum .15 A maximum, 4.5 VA maximum resistive.
Standard Block
Continuous
Current
Amperes
Inrush
Current
Amperes
230
6.0
3.0
460
575
1.5
1.2
60
30
15
12
—
—
AC Volts
115
Publication Number
0,1
2
3,4
5,6
GEH-4758
GEH-4759
GEH-4760
GEH-4761
GEH-5109
GEH-5178
GEH-5185
GEH-5186
GEH-5187
7-9
Note: CR305X logic reed switch auxiliary contacts may be
ordered as a factory-installed modification. Order by description.
For factory-installed modification, add $75.00, GO-10G, per
circuit to price of starter/contactor.
Instructions
NEMA Size
0, 1 Logic Reed
2 Logic Reed
3, 4 Logic Reed
5, 6 Logic Reed
® First adder block must be mounted to a basic block. A second adder
block can be added to the first adder block on size 2 through size 6
contactors and starters.
Prices and data subject to change without notice
1999 Issue
Continuous
Current
Amperes
Inrush
Current
Amperes
125
1.1
250
—
0.5
—
_
—
—
—
DC Volts
1-57