MASTERTEMP®125 HIGH PERFORMANCE HEATER INSTALLATION AND USER’S GUIDE FOR YOUR SAFETY - READ BEFORE OPERATING ,I\RXGRQRWIROORZWKHVHLQVWUXFWLRQVH[DFWO\D¿UHRUH[SORVLRQPD\UHVXOWFDXVLQJ SURSHUW\GDPDJHSHUVRQDOLQMXU\RUORVVRIOLIH)RUDGGLWLRQDOIUHHFRSLHVRIWKLV PDQXDOFDOO FOR YOUR SAFETY - This product must be installed and serviced by authorized personnel, qualified inpool/spa heater installation. Improper installation and/or operation can create carbon monoxide gas and flue gases which can cause serious injury, property damage, or death. For indoor installations, as an additional measure of safety, Pentair Aquatic Systems strongly recommends installation of suitable Carbon Monoxide detectors in the vicinity of this appliance and in any adjacent occupied spaces. Improper installation and/or operation will void the warranty. 120/240 VAC NATURAL GAS/LP GAS Models Natural Propane 125K BTU/HR (without cord) 125K BTU/HR (with cord) 461058 461059 461060 461061 OWNER: Retain For Future Reference ,PSURSHULQVWDOODWLRQDGMXVWPHQWDOWHUDWLRQVHUYLFHRUPDLQWHQDQFHFDQFDXVH SURSHUW\GDPDJHSHUVRQDOLQMXU\RUGHDWK,QVWDOODWLRQDQGVHUYLFHPXVWEHSHUIRUPHG E\DTXDOL¿HGLQVWDOOHUVHUYLFHDJHQF\RUWKHJDVVXSSOLHU WHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY 'RQRWWU\WROLJKWDQ\DSSOLDQFH 'RQRWWRXFKDQ\HOHFWULFDOVZLWFKGRQRWXVHDQ\SKRQHLQ\RXUEXLOGLQJ ,PPHGLDWHO\FDOO\RXUJDVVXSSOLHUIURPDQHLJKERU¶VSKRQH )ROORZWKHJDVVXSSOLHU¶VLQVWUXFWLRQV ,I\RXFDQQRWUHDFK\RXUJDVVXSSOLHUFDOOWKH¿UHGHSDUWPHQW '2127VWRUHRUXVHJDVROLQHRURWKHUÀDPPDEOHYDSRUVDQGOLTXLGVLQWKHYLFLQLW\ RIWKLVRURWKHUDSSOLDQFHV Pentair Water Pool and Spa, Inc. 1620 Hawkins Ave., Sanford, NC 27330 ɒ (800) 831-7133 or (919) 566-8000 10951 W. Los Angeles Ave., Moorpark, CA 93021 ɒ (800) 831-7133 or (805) 553-5000 2 Customer Service and Technical Support If you have questions about ordering Pentair Aquatic Systems replacement parts, and pool products, please call: Phone: (800) 831-7133 - (8 AM to 4:30 PM Pacific Time and Eastern Time) Fax: (800) 284-4151 Web sites: www.pentairpool.com - www.staritepool.com P/N 475000 Rev. A MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 3 Contents 6HFWLRQ+HDWHU,GHQWL¿FDWLRQ,QIRUPDWLRQ......................................................................... 6HFWLRQ:DUQLQJDQG6DIHW\,QIRUPDWLRQ.......................................................................... 4 5 Important Notices ................................................................................................................................................................................. Warranty Information ............................................................................................................................................................................ Code Requirements.............................................................................................................................................................................. Consumer Information and Safety Information ..................................................................................................................................... General Specifications.......................................................................................................................................................................... 5 5 6 6-9 9 Section 3. Installation .............................................................................................................. 10 Heater Description ................................................................................................................................................................................ 10 Putting the Heater into Service ............................................................................................................................................................. 10 Specifications ....................................................................................................................................................................................... 11 Plumbing Connections.......................................................................................................................................................................... 12 Valves ................................................................................................................................................................................................... 12 Manual By-Pass ................................................................................................................................................................................... 12 Water Connections ............................................................................................................................................................................... 13 Below Pool Installation ......................................................................................................................................................................... 13 Gas Connections .................................................................................................................................................................................. 14 Sediment Traps ................................................................................................................................................................................... 14 Gas Pipe Sizing .................................................................................................................................................................................... 15 Testing Gas Pressure/Gas Pressure Requirements ............................................................................................................................. 15 Outdoor Installation (US and Canada) / Heater Clearances ................................................................................................................ 16 Outdoor Installation Venting Guidelines .............................................................................................................................................. 17 Indoor Venting — General Requirements (Category I and Category III requirements) ...................................................................... 17 Heater Clearances — General Requirements (Indoor Installation for US or Outdoor Shelter for Canada) ....................................... 18 Outside Vent Cover Removal ............................................................................................................................................................... 18 Combustion Air Supply ......................................................................................................................................................................... 18 Direct Air Intake Exhaust Duct using 3-inch PVC Pipe (Indoor Installation) / Corrosive Vapors and Possible Causes ........................ 19 Vent Installation (Indoor Installation for U.S. or Outdoor Shelter for Canada) ...................................................................................... 20 Vertical Venting - Negative Pressure ................................................................................................................................................... 20 - 22 Horizontal or Vertical Venting - Positive Pressure ............................................................................................................................... 23 Connecting Special Gas Venting .......................................................................................................................................................... 23 - 25 Outdoor Shelter Vent Installation .......................................................................................................................................................... 26 Garage or Utility Room Installation ....................................................................................................................................................... 26 Control Panel Indexing ......................................................................................................................................................................... 27 Final Installation Check ........................................................................................................................................................................ 27 Electrical Connections .......................................................................................................................................................................... 28 Fireman’s Switch Connection/Remote Control Connections ................................................................................................................ 29 MasterTemp® 125 Heater Wiring Diagram ........................................................................................................................................... 30 Electrical Schematic Ladder Diagram .................................................................................................................................................. 31 Section 4. Operation ................................................................................................................ 32 Basic System Operation ....................................................................................................................................................................... 32 HSI (Hot-Surface Ignition) Lighting/Operation ...................................................................................................................................... 32 Operating ............................................................................................................................................................................................. 33 To Turn Off Gas to Appliance ................................................................................................................................................................ 33 Safety Controls ..................................................................................................................................................................................... 34 - 36 Section 5. Troubleshooting .................................................................................................... 37 Initial Troubleshooting and Troubleshooting Chart ............................................................................................................................... 38 Heater Will Not Fire Troubleshooting .................................................................................................................................................... 39 - 42 LED Diagnostics ................................................................................................................................................................................... 43 - 44 Burner / Heat Exchanger Troubleshooting ........................................................................................................................................... 45 Section 6. Maintenance ........................................................................................................... 45 Care and Maintenance ......................................................................................................................................................................... 46 Pressure Relief Valve ........................................................................................................................................................................... 45 After Start-Up........................................................................................................................................................................................ 46 Spring, Fall and Winter Operation ........................................................................................................................................................ 46 Maintaining Pool Temperature .............................................................................................................................................................. 47 Energy Saving Tips............................................................................................................................................................................... 48 Chemical Balance................................................................................................................................................................................. 47 - 48 Replacement Parts ............................................................................................................................................................................... 49 - 53 Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 4 Section 1. Heater Identification Information Section 1: Heater Identification Information 7RLGHQWLI\WKHKHDWHUVHHUDWLQJSODWHRQWKHLQQHUIURQWSDQHORIWKHKHDWHU7KHUHDUHWZRGHVLJQDWRUVIRUHDFKKHDWHU RQHLVWKH0RGHO1XPEHUDQGWKHRWKHULVWKH+HDWHU,GHQWL¿FDWLRQ1XPEHU+,1 D +HDWHU,GHQWL¿FDWLRQ1XPEHU+,1 7KHIROORZLQJexampleVLPSOL¿HVWKHLGHQWL¿FDWLRQV\VWHP MT0DVWHU7HPS125 Model Size125,QSXWUDWLQJ%WXKU; Fuel Type LP 3URSDQHJDVRU1$ 1DWXUDOJDV Construction STD 6WDQGDUG0RGHO HEATER IDENTIFICATION INFORMATION — (HIN) H. I. N. HEATER IDENTIFICATION NUMBER ID DESIGNATOR FOR PENTAIR AQUATIC SYSTEMS MASTERTEMP® 125 HEATER Example: 1 2 3 4 MT 125 NA STD CONSTRUCTION = STD = STANDARD MODEL FUEL TYPE = NA = NATURAL GAS LP = PROPANE GAS MODEL SIZE = BTU INPUT in 1000 of BTU / HR MT = MASTERTEMP MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 2. Warning and Safety Instructions 5 Section 2: Warning and Safety Instructions IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS MasterTemp® 125 High Performance Heater &RQJUDWXODWLRQV RQ \RXU SXUFKDVH RI D 0DVWHU7HPS® KLJK SHUIRUPDQFH KHDWLQJ V\VWHP 3URSHU LQVWDOODWLRQ DQG VHUYLFHRI\RXUQHZKHDWLQJV\VWHPDQGFRUUHFWFKHPLFDOPDLQWHQDQFHRIWKHZDWHUZLOOHQVXUH\HDUVRIHQMR\PHQW7KH 0DVWHU7HPS®KHDWHULVDFRPSDFWOLJKWZHLJKWHI¿FLHQWLQGXFHGGUDIWJDV¿UHGKLJKSHUIRUPDQFHSRRODQGVSDKHDWHU WKDWFDQEHGLUHFWO\FRQQHFWHGWRVFKHGXOH39&SLSH7KHKHDWHUDOVRFRPHVHTXLSSHGZLWKWKH3HQWDLUPXOWLIXQFWLRQ WHPSHUDWXUHFRQWUROOHUZKLFKVKRZVDWDJODQFHWKHSURSHUIXQFWLRQLQJRIWKHKHDWHU$OO0DVWHU7HPS®KHDWHUVDUH GHVLJQHGZLWKDGLUHFWLJQLWLRQGHYLFH+6,KRWVXUIDFHLJQLWLRQZKLFKHOLPLQDWHVWKHQHHGIRUDVWDQGLQJSLORW7KH 0DVWHU7HPS®KHDWHUUHTXLUHVDQH[WHUQDOSRZHUVRXUFH9$&+]WRRSHUDWH 63(&,$/,16758&7,216722:1(55HWDLQWKLVPDQXDOIRUIXWXUHUHIHUHQFH7KLVLQVWUXFWLRQPDQXDOSURYLGHV RSHUDWLQJ LQVWUXFWLRQV LQVWDOODWLRQ DQG VHUYLFH LQIRUPDWLRQ IRU WKH 0DVWHU7HPS® KLJK SHUIRUPDQFH KHDWHU7KH LQIRUPDWLRQLQWKLVPDQXDODSSOLHVWRDOO0DVWHU7HPS®KHDWHUPRGHOV5($'$1'5(9,(:7+,60$18$/ &203/(7(/< LW LV YHU\ LPSRUWDQW WKDW WKH RZQHULQVWDOOHU UHDG DQG XQGHUVWDQG WKH VHFWLRQ FRYHULQJ LQVWDOODWLRQ LQVWUXFWLRQVDQGUHFRJQL]HWKHORFDODQGVWDWHFRGHVEHIRUHLQVWDOOLQJWKH0DVWHU7HPS®KHDWHU,WVXVHZLOOUHGXFH VHUYLFHFDOOVDQGFKDQFHRILQMXU\DQGZLOOOHQJWKHQSURGXFWOLIH+LVWRU\DQGH[SHULHQFHKDVVKRZQWKDWPRVWKHDWHU GDPDJHLVFDXVHGE\LPSURSHULQVWDOODWLRQSUDFWLFHV IMPORTANT NOTICES )RUWKHLQVWDOOHUDQGRSHUDWRURIWKH0DVWHU7HPS®SRRODQGVSDKHDWHU7KHPDQXIDFWXUHU¶VZDUUDQW\PD\EHYRLG LIIRUDQ\UHDVRQWKHKHDWHULVLPSURSHUO\LQVWDOOHGDQGRURSHUDWHG%HVXUHWRIROORZWKHLQVWUXFWLRQVVHWIRUWKLQWKLV PDQXDO,I\RXQHHGDQ\PRUHLQIRUPDWLRQRULI\RXKDYHDQ\TXHVWLRQVUHJDUGLQJWRWKLVSRROKHDWHUSOHDVHFRQWDFW 3HQWDLU$TXDWLF6\VWHPVDW WARRANTY INFORMATION 7KH0DVWHU7HPSSRROKHDWHULVVROGZLWKDOLPLWHGIDFWRU\ZDUUDQW\ 6SHFL¿FGHWDLOVDUHGHVFULEHGRQWKHZDUUDQW\UHJLVWUDWLRQFDUGZKLFKLVLQFOXGHGZLWKWKHSURGXFW5HWXUQWKHZDUUDQW\UHJLVWUDWLRQFDUGDIWHU¿OOLQJLQWKH VHULDOQXPEHUIURPWKHUDWLQJSODWHLQVLGHWKHKHDWHU 3HQWDLU$TXDWLF6\VWHPVKLJKVWDQGDUGVRIH[FHOOHQFHLQFOXGHDSROLF\RIFRQWLQXRXVSURGXFWLPSURYHPHQWUHVXOWLQJ LQ\RXUVWDWHRIWKHDUWKHDWHU:HUHVHUYHWKHULJKWWRPDNHLPSURYHPHQWVZKLFKFKDQJHWKHVSHFL¿FDWLRQVRIWKH KHDWHUZLWKRXWLQFXUULQJDQREOLJDWLRQWRXSGDWHWKHFXUUHQWKHDWHUHTXLSPHQW 7KHVHKHDWHUVDUHGHVLJQHGIRUWKHKHDWLQJRIFKORULQHEURPLQHRUVDOWV\VWHPVZLPPLQJSRROVDQGVSDVRULQ QRQVWDWLRQDU\LQVWDOODWLRQVDQGVKRXOGQHYHUEHHPSOR\HGIRUXVHDVVSDFHKHDWLQJERLOHUVRUJHQHUDOSXUSRVH ZDWHUKHDWHUV7KHPDQXIDFWXUHU¶VZDUUDQW\PD\EHYRLGLIIRUDQ\UHDVRQWKHKHDWHULVLPSURSHUO\LQVWDOOHG DQGRURSHUDWHG%HVXUHWRIROORZWKHLQVWUXFWLRQVVHWIRUWKLQWKLVPDQXDO CAUTION OPERATING THIS HEATER CONTINUOUSLY AT WATER TEMPERATURE BELOW 68° F. WILL CAUSE HARMFUL CONDENSATION AND WILL DAMAGE THE HEATER AND VOID THE WARRANTY. Do not use the heater to protect pools or spas from freezing if the final maintenance temperature desired is below 68° F., as this will cause condensation related problems. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 6 Section 2. Warning and Safety Instructions CODE REQUIREMENTS ,QVWDOODWLRQPXVWEHLQDFFRUGDQFHZLWKDOOORFDOFRGHVDQGRUWKHODWHVWHGLWLRQRIWKH1DWLRQDO)XHO*DV&RGH $16,=DQGWKHODWHVWHGLWLRQRIWKH1DWLRQDO(OHFWULFDO&RGH1)3$86 ,QVWDOODWLRQLQ&DQDGDPXVWEHLQDFFRUGDQFHZLWKWKHODWHVW&$1&*$%RUDQG&6$&&DQDGLDQ (OHFWULF&RGHSDUW 7KHKHDWHUZKHQLQVWDOOHGPXVWEHHOHFWULFDOO\JURXQGHGDQGERQGHGLQDFFRUGDQFHZLWKORFDOFRGHVRULQDEVHQFH RIORFDOFRGHVZLWKWKH1DWLRQDO(OHFWULFDO&RGH$16,1)3$86RULQ&DQDGDLQDFFRUGDQFHZLWKWKH&DQDGLDQ (OHFWULF&RGHSDUWDVDSSOLFDEOH DANGER CARBON MONOXIDE GAS IS DEADLY – Exhaust from this pool heater contains toxic levels of carbon monoxide, a dangerous, poisonous gas you cannot see or smell. CONSUMER INFORMATION AND SAFETY WARNING The U.S. Consumer Product Safety Commission warns that elevated water temperature can be hazardous. See below for water temperature guidelines before setting temperature. 6SDRUKRWWXEZDWHUWHPSHUDWXUHVVKRXOGQHYHUH[FHHG)&$WHPSHUDWXUHRI)&LVFRQVLGHUHG VDIHIRUDKHDOWK\DGXOW6SHFLDOFDXWLRQLVVXJJHVWHGIRU\RXQJFKLOGUHQ 'ULQNLQJ RI DOFRKROLF EHYHUDJHV EHIRUH RU GXULQJ VSD RU KRW WXE XVH FDQ FDXVH GURZVLQHVV ZKLFK FRXOG OHDG WR XQFRQVFLRXVQHVVDQGVXEVHTXHQWO\UHVXOWLQGURZQLQJ 3UHJQDQWZRPHQEHZDUH6RDNLQJLQZDWHUDERYH)&FDQFDXVHIHWDOGDPDJHGXULQJWKH¿UVWWKUHH PRQWKVRISUHJQDQF\UHVXOWLQJLQWKHELUWKRIDEUDLQGDPDJHGRUGHIRUPHGFKLOG3UHJQDQWZRPHQVKRXOGVWLFN WRWKH)&PD[LPXPUXOH %HIRUHHQWHULQJWKHVSDRUKRWWXEWKHXVHUVKRXOGFKHFNWKHZDWHUWHPSHUDWXUHZLWKDQDFFXUDWHWKHUPRPHWHU6SD RUKRWWXEWKHUPRVWDWVPD\HUULQUHJXODWLQJZDWHUWHPSHUDWXUHVE\DVPXFKDV)& 3HUVRQVZLWKDPHGLFDOKLVWRU\RIKHDUWGLVHDVHFLUFXODWRU\SUREOHPVGLDEHWHVRUEORRGSUHVVXUHSUREOHPVVKRXOG REWDLQWKHLUSK\VLFLDQ¶VDGYLFHEHIRUHXVLQJVSDVRUKRWWXEV 3HUVRQVWDNLQJPHGLFDWLRQZKLFKLQGXFHGURZVLQHVVVXFKDVWUDQTXLOL]HUVDQWLKLVWDPLQHVRUDQWLFRDJXODQWVVKRXOG QRWXVHVSDVRUKRWWXEV WARNING Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the heater. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of control system and gas control which has been under water. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 2. Warning and Safety Instructions 7 SAFETY INFORMATION The MasterTemp® 125 Heater is designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this manual. Throughout this manual, safety warnings and cautions are identified by the “ “ symbol. Be sure to read and comply with all of the warnings and cautions. DANGER — CARBON MONOXIDE GAS IS DEADLY READ OWNERS MANUAL COMPLETELY BEFORE OPERATING THIS PRODUCT MUST BE INSTALLED AND SERVICED BY A PROFESSIONAL SERVICE TECHNICIAN, QUALIFIED IN POOL HEATER INSTALLATION. Some jurisdictions require that installers be licensed. Check with your local building authority about contractor licensing requirements. Improper installation and/or operation could create carbon monoxide gas and flue gases which could cause serious injury or death. Improper installation and/or operation will void the warranty. Exhaust from this pool heater contains toxic levels of carbon monoxide, a dangerous, poisonous gas you cannot see or smell. Symptoms of carbon monoxide exposure or poisoning include dizziness, headache, nausea, weakness, sleepiness, muscular twitching, vomiting and inability to think clearly. IF YOU EXPERIENCE ANY OF THE ABOVE SYMPTOMS, IMMEDIATELY TURN OFF THE POOL HEATER, LEAVE THE VICINITY OF THE POOL OR SPA AND GET INTO FRESH AIR IMMEDIATELY. THE POOL HEATER MUST BE THOROUGHLY TESTED BY A GAS PROFESSIONAL BEFORE RESUMING OPERATION. EXCESSIVE CARBON MONOXIDE EXPOSURE CAN CAUSE BRAIN DAMAGE OR DEATH. sNEVER use this pool heater indoors without specified ventilation system (and properly installed vent pipe). sNEVER use this pool heater in the home or in partly enclosed areas (such as garages), unless the specified ventilation system is used. If used outdoors, install far from open windows, doors, vents and other openings. s Pentair strongly recommends that all vents, pipes and exhaust systems be initially and periodically tested for proper operation. This testing can be accomplished by using a hand-held carbon monoxide meter and/or by consulting with a gas professional. s Pool heaters must be used in conjunction with carbon monoxide detectors installed near the pool heater. The carbon monoxide detectors must be periodically inspected for proper operation so WARNING — FOR YOUR SAFETY This product must be installed and serviced by a professional service technician, qualified in pool heater installation. Some jurisdictions require that installers be licensed. Check with your local building authority about contractor licensing requirements. Improper installation and/or operation could create carbon monoxide gas and flue gases which could cause serious injury or death. Improper installation and/or operation will void the warranty. WARNING — This heater is equipped with an unconventional gas control valve that is factory set with a manifold pressure of -.2 inches wc. Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Installation or service must be performed by a qualified installer, service agency or the gas supplier. If this control is replaced, it must be replaced with an identical control. Do not attempt to adjust the gas flow by adjusting the regulator setting. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 8 Section 2. Warning and Safety Instructions SAFETY INFORMATION, (cont’d.) WARNING — Risk of fire or explosion from incorrect fuel use or faulty fuel conversion. Do not try to run a heater set up for natural gas on propane gas or vice versa. Only qualified service technicians should attempt to convert heater from one fuel to the other. Do not attempt to alter the rated input or type of gas by changing the orifice. If it is necessary to convert to a different type of gas, consult your Pentair dealer. Serious malfunction of the burner can occur which may result in loss of life. Any additions, changes, or conversions required in order for the appliance to satisfactorily meet the application needs must be made by a Pentair dealer or other qualified agency using factory specified and approved parts. The heater is available for use with natural gas or LP (propane) gas only. It is not designed to operate with any other fuels. Refer to the nameplate for the type of gas the heater is equipped to use. s 5SEHEATERONLYWITHTHEFUELFORWHICHITISDESIGNED s )F A FUEL CONVERSION IS NECESSARY REFER THIS WORK TO A QUALIlED SERVICE TECHNICIAN OR GAS SUPPLIER before putting the heater into operation. WARNING — Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile flammable liquids near heater or in the same room with heater. WARNING — Risk of explosion if unit is installed near propane gas storage. Propane (LP) gas is heavier than air. Consult local codes and fire protection authorities about specific installation requirements and restrictions. Locate the heater away from propane gas storage and filling equipment as specified by the Standard for the Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2 (latest edition) or ANSI/NFPA 58 (latest edition). WARNING — Risk of fire, carbon monoxide poisoning, or asphyxiation if exhaust venting system leaks. Only qualified service technicians should attempt to service the heater, as leakage of exhaust products or flammable gas may result from incorrect servicing. WARNING — Risk of asphyxiation if exhaust is not correctly vented. Follow venting instructions exactly when installing heater. Do not use a draft hood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room housing the heater. The heater is supplied with an integral venting system for outdoor installation. A vent conversion kit (See Page 23 for Part Numbers for Conversion Kits) is available for installations in enclosures Canada) or indoors (U.S.). Use the specified venting, and only the specified venting, when heater is installed in an enclosure or indoors. In Canada, this pool heater can only be installed outdoors or in an enclosure that is not normally occupied and has no openings directly into occupied areas. See Page 18 for enclosure venting requirements. CAUTION — Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Wiring errors can also destroy the control board. s #ONNECTHEATERTO120 or 240 Volt, 60 Hz., Single Phase power only. s 6ERIFYPROPEROPERATIONAFTERSERVICING s $ONOTALLOWCHILDRENTOPLAYONORAROUNDHEATERORASSOCIATEDEQUIPMENT s .EVERALLOWCHILDRENTOUSETHEPOOLORSPAWITHOUTADULTSUPERVISION s 2EAD AND FOLLOW OTHER SAFETY INFORMATION CONTAINED IN THIS MANUAL PRIOR TO OPERATING THIS POOL heater. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 2. Warning and Safety Instructions 9 CONSUMER INFORMATION AND SAFETY WARNING The U.S. Consumer Product Safety Commission warns that carbon monoxide is an “invisible killer”. Carbon monoxide is a colorless and odorless gas. &DUERQPRQR[LGHLVSURGXFHGE\EXUQLQJIXHOLQFOXGLQJQDWXUDOJDVDQGSURSDQH 3URSHULQVWDOODWLRQRSHUDWLRQDQGPDLQWHQDQFHRIIXHOEXUQLQJDSSOLDQFHVLQWKHKRPHLVWKHPRVWLPSRUWDQW IDFWRULQUHGXFLQJFDUERQPRQR[LGHSRLVRQLQJ %HVXUHWKDWIXHOEXUQLQJDSSOLDQFHVVXFKDVKHDWHUVDUHLQVWDOOHGE\SURIHVVLRQDOVDFFRUGLQJWRPDQXIDFWXUHU¶V LQVWUXFWLRQVDQGFRGHV $OZD\VIROORZWKHPDQXIDFWXUHU¶VGLUHFWLRQVIRUVDIHRSHUDWLRQ +DYHWKHKHDWLQJV\VWHPLQFOXGLQJYHQWVLQVSHFWHGDQGVHUYLFHGDQQXDOO\E\DWUDLQHGVHUYLFHWHFKQLFLDQ ([DPLQHYHQWVUHJXODUO\IRULPSURSHUFRQQHFWLRQVYLVLEOHFUDFNVUXVWRUVWDLQV ,QVWDOOEDWWHU\RSHUDWHGFDUERQPRQR[LGHDODUPV7KHDODUPVVKRXOGEHFHUWL¿HGWRWKHUHTXLUHPHQWVRIWKH PRVWUHFHQW8/,$6&6$DQG,$302VWDQGDUGIRUFDUERQPRQR[LGHDODUPV7HVWFDUERQPRQR[LGHDODUPV UHJXODUO\DQGUHSODFHGHDGEDWWHULHV GENERAL SPECIFICATIONS NOTICE: s #OMBUSTIONAIRCONTAMINATEDBYCORROSIVECHEMICALFUMESCANDAMAGETHEHEATERANDWILLVOIDTHEWARRANTY s 4HE#OMBINATION'AS#ONTROL6ALVEONTHISHEATERDIFFERSFROMMOSTAPPLIANCEGASCONTROLS)FITMUSTBEREPLACED for safety reasons replace it only with an identical gas control. s 4HEACCESSDOORPANELSMUSTBEINPLACETOPROVIDEPROPERVENTILATION$ONOTOPERATETHEHEATERFORMORETHANlVE minutes with the access door panels removed. s 4HISHEATERISDESIGNCERTIlEDBY#3!)NTERNATIONALASCOMPLYINGWITHTHE3TANDARDFOR'AS&IRED0OOL(EATERS ANSI Z21.56/CSA 4.7, and is intended for use in heating fresh water swimming pools or spas. s 4HEHEATERISDESIGNEDFORTHEHEATINGOFCHLORINEBROMINEORSALTSYSTEMSWIMMINGPOOLSANDSPAS)TSHOULDNOT be used as a space heating boiler, or general purpose water heater. s 4HEHEATERISDESIGNCERTIlEDBY#3!)NTERNATIONALFORINSTALLATIONONCOMBUSTIBLEmOORING3PECIlEDMINIMUM clearances must be maintained to combustible surfaces (see “Heater Clearances”, page 18). s 4HEHEATERSHOULDBELOCATEDINANAREAWHERELEAKAGEOFTHEHEATERORCONNECTIONSWILLNOTRESULTINDAMAGETOTHE area adjacent to the heater or to the structure. When such locations cannot be avoided, it is recommended that a suitable drain pan, adequately drained, be installed under the heater. The pan must not restrict air flow. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 10 Section 3. Installation Instructions Section 3: Installation Instructions 7ZRLQFK39&ZDWHUSLSLQJFRQQHFWVGLUHFWO\WRWKHPDQLIROGKHDGHURQ WKHKHDWH[FKDQJHUXVLQJ´39&VOLSXQLRQVSURYLGHGZLWKWKHKHDWHU 7KHRXWHUPDQLIROGUHPDLQVFRROQRKHDWVLQNVDUHUHTXLUHG$WKHUPDO UHJXODWRUDQGDQLQWHUQDOE\SDVVUHJXODWHWKHZDWHUÀRZWKURXJKWKHKHDW H[FKDQJHUWRPDLQWDLQWKHFRUUHFWRXWOHWWHPSHUDWXUH7KHKHDWHURSHUDWRU FRQWUROSDQHOERDUGDVVHPEO\LVORFDWHGRQWRSRIWKHKHDWHU Exhaust )LJXUH LV D GLDJUDP RI WKH KHDWHU VKRZLQJ KRZ LW RSHUDWHV 3UHFLVHO\PDWFKHGRUL¿FHSODWHVPHWHUWKHDLUDQGJDVLQWRWKHPL[HU 7KHEORZHUGUDZVWKHDLUDQGJDVWKURXJKWKHPL[HUDQGIRUFHVLWLQWR WKHEXUQHU¶VÀDPHKROGHU$VHDOHGKHDWH[FKDQJHUVXUURXQGVWKHÀDPH KROGHUGLVFKDUJLQJH[KDXVWJDVHVRXWWKHÀXH Gas HEATER DESCRIPTION Air Blower Mixer Inlet (Cold Water) Outlet (Mixed Water) Burner Heating Coils SEQUENCE OF OPERATION Figure 1. $QHOHFWURQLFWHPSHUDWXUHVHQVLQJWKHUPLVWRULQWKHPDQLIROGDGDSWHULQOHWFRQWUROVWKHKHDWHURSHUDWLRQ:KHQWKHLQOHW ZDWHUWHPSHUDWXUHGURSVEHORZWKHWHPSHUDWXUHVHWRQWKHRSHUDWLQJFRQWUROWKHEXUQHUFRQWUROOHUVXSSOLHVSRZHUWRWKH FRPEXVWLRQDLUEORZHUWKURXJKDVHULHVRIVDIHW\LQWHUORFNV7KHLQWHUORFNVFRQVLVWRI WKHSUHVVXUHVZLWFKPSZKLFKVHQVHVWKDWWKHSXPSLVUXQQLQJ WKHKLJKOLPLWVZLWFKHLSZKLFKRSHQVLIWKHKHDWH[FKDQJHURXWOHWWHPSHUDWXUHJRHVDERYH)&DQG WKHDLUÀRZVZLWFK$)6ZKLFKVHQVHVWKHSUHVVXUHGURSDFURVVWKHDLUPHWHULQJRUL¿FH WKH DXWRPDWLF JDV VKXWRII $*6 VZLWFK ZKLFK RSHQV LI WKH KHDW H[FKDQJHU RXWOHW WHPSHUDWXUH JRHV DERYH )& WKHVWDFNÀXHVHQVRU6)6ZKLFKVKXWVGRZQWKHKHDWHULIWKHÀXHJDVWHPSHUDWXUHUHDFKHV)& 7KHDLUÀRZVZLWFK$)6VHQVHVWKHSUHVVXUHGURSDFURVVWKHDLUPHWHULQJRUL¿FH$VVRRQDVWKHUHLVVXI¿FLHQWDLUÀRZ WKH$)6FORVHVFORVLQJWKHFLUFXLWWRWKHKRWVXUIDFHLJQLWHUHSIZKLFKLJQLWHVWKHIXHOPL[WXUH2QDFDOOIRUKHDWWKH EORZHUDQG+6,DUHHQHUJL]HG,QDERXWVHFRQGVWKHJDVYDOYHRSHQVDQGLJQLWLRQRFFXUV7KH+6,WKHQVZLWFKHVWRD VHQVLQJPRGHDQGPRQLWRUVWKHÀDPH 7KH KHDWHU LV HTXLSSHG ZLWK D GLJLWDO RSHUDWLQJ FRQWURO WKDW HQDEOHV WKH XVHU WR SUHVHW WKH GHVLUHG SRRO DQG VSD ZDWHU WHPSHUDWXUHV7KHFRQWUROHQDEOHVWKHXVHUWRVHOHFWEHWZHHQSRRODQGVSDKHDWLQJDQGIHDWXUHVDGLJLWDOGLVSOD\WKDWLQGLFDWHV WKHZDWHUWHPSHUDWXUH PUTTING THE HEATER INTO SERVICE ,IWKHKHDWHULVLQVWDOOHGEHORZWKHOHYHORIWKHSRRORUPRUHWKDQWZRIHHWDERYHSRROOHYHOWKHSUHVVXUHVZLWFKVHWWLQJ VKRXOGEHDGMXVWHG6HH:$7(535(6685(6:,7&+LQWKH6$)(7<&21752/66HFWLRQ %HIRUHSXWWLQJWKHKHDWHULQWRVHUYLFHIRUWKH¿UVWWLPHIROORZWKHLQVWUXFWLRQVXQGHU³%()25(67$5783´SDJHLQWKH IURQWRIWKLVPDQXDO&KHFNIRUSURSHURSHUDWLRQRIWKHKHDWHUE\IROORZLQJWKHVWHSVXQGHU³23(5$7,21,16758&7,216´ 'DPDJHWRHTXLSPHQWFDXVHGE\LPSURSHULQVWDOODWLRQRUUHSDLUZLOOYRLGWKHZDUUDQW\ MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions 11 SPECIFICATIONS 7KHVHLQVWDOODWLRQLQVWUXFWLRQVDUHGHVLJQHGIRUXVHE\TXDOL¿HGSHUVRQQHORQO\WUDLQHGHVSHFLDOO\IRULQVWDOODWLRQRIWKLV W\SHRIKHDWLQJHTXLSPHQWDQGUHODWHGFRPSRQHQWV6RPHVWDWHVUHTXLUHLQVWDOODWLRQDQGUHSDLUE\OLFHQVHGSHUVRQQHO ,IWKLVDSSOLHVLQ\RXUVWDWHEHVXUH\RXUFRQWUDFWRUEHDUVWKHDSSURSULDWHOLFHQVH6HH)LJXUHIRU2XWGRRUDQG,QGRRU ,QVWDOODWLRQV 20.85" 52.95cm DIMENSIONS IN INCHES ELECTRICAL CONDUIT PORT 29.43" 74.76 17.5" 44.5cm 21" 53 cm 10.87" 28.cm FRONT VIEW TOP VIEW 23" 58.4cm 10.87" 27.6cm EXHAUST SIDE VIEW 5.5" 14cm PLUMBING SIDE VIEW Figure 2. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 12 Section 3. Installation Instructions PLUMBING CONNECTIONS Figure 3. 7KH 0DVWHU7HPS® KHDWHU KDV WKH XQLTXH FDSDELOLW\ RI GLUHFW VFKHGXOH 39& SOXPELQJ FRQQHFWLRQV $ VHW RI EXONKHDG ¿WWLQJV LV LQFOXGHG ZLWK WKH 0DVWHU7HPS KHDWHU WR LQVXUH FRQIRUPLW\ ZLWK 3HQWDLU¶V UHFRPPHQGHG 39&SOXPELQJSURFHGXUH2WKHUSOXPELQJFRQQHFWLRQVFDQ EHXVHG6HH)LJXUHIRUSOXPELQJFRQQHFWLRQV CAUTION HEATER TO POOL FROM FILTER Before operating the heater on a new installation, turn on the circulation pump and bleed all the air from the filter using the air relief valve on top of the filter. Water should flow freely through the heater. Do not operate the heater unless water in the pool/spa is at the proper level. If a manual by-pass is installed, temporarily close it to insure that all air is purged from the heater. PUMP FILTER MANUAL BY-PASS GATE VALVE FROM POOL 3-Way Valve WATER CONNECTIONS 7KH KHDWHU UHTXLUHV SURSHU ZDWHU ÀRZ DQG SUHVVXUH IRU LWV RSHUDWLRQ6HH)LJXUHIRUWKHUHFRPPHQGHGLQVWDOODWLRQ7KH ¿OWHUSXPSGLVFKDUJHVWRWKH¿OWHUWKH¿OWHUGLVFKDUJHVWRWKH KHDWHUDQGWKHKHDWHUGLVFKDUJHVGLUHFWO\WRWKHSRRORUVSD $PDQXDOE\SDVVYDOYHVKRXOGEHLQVWDOOHGDFURVVWKHKHDWHU ZKHQ WKH SXPS ÀRZ H[FHHGV *30 /30 6HH ³:$7(5)/2:5$7(´7DEOHRQSDJHIRUVHWWLQJRI WKHPDQXDOE\SDVVYDOYH 0DNHVXUHWKDWWKHRXWOHWSOXPELQJIURPWKHKHDWHUFRQWDLQV QRVKXWRIIYDOYHVRURWKHUÀRZUHVWULFWLRQVWKDWFRXOGSUHYHQW ÀRZWKURXJKWKHKHDWHUH[FHSWIRUSRROLQVWDOODWLRQVDVQRWHG EHORZRUZLQWHUL]LQJYDOYHVZKHUHQHHGHG7RVZLWFKÀRZ EHWZHHQWKHSRRODQGVSDXVHDGLYHUWHUYDOYH'RQRWXVH DQ\YDOYHWKDWFDQVKXWRIIWKHÀRZ Chlorinator Check Valve Heater Main Drain Filter Spa Pool Pump From Pool 3-Way Valve 3-Way Valve Figure 4. ,QVWDOOWKHFKHPLFDOIHHGHUGRZQVWUHDPRIWKHKHDWHU,QVWDOODFKHPLFDOUHVLVWDQWRQHZD\FKHFNYDOYHEHWZHHQWKH KHDWHUDQGWKHFKHPLFDOIHHGHUWRSUHYHQWEDFNVLSKRQLQJWKURXJKWKHKHDWHUZKHQWKHSXPSLVRII NOTICE:,IWKHKHDWHULVSOXPEHGLQEDFNZDUGVLWZLOOF\FOHFRQWLQXRXVO\0DNHVXUHSLSLQJIURP¿OWHULVQRWUHYHUVHG ZKHQLQVWDOOLQJKHDWHU &RQQHFWWKHKHDWHUGLUHFWO\WR´39&SLSHXVLQJWKHLQWHJUDOXQLRQVSURYLGHG+HDWVLQNVDUHQRWUHTXLUHG7KHORZ WKHUPDOPDVVRIWKHKHDWHUZLOOSUHYHQWRYHUKHDWLQJRIWKHSLSLQJFRQQHFWHGWRWKHSXPSHYHQLIWKHKHDWHUVKXWVGRZQ XQH[SHFWHGO\,I\RXDUHXVLQJDÀH[LEOHFRUUXJDWHGKRVHIRUDERYHJURXQGV\VWHPVXVHRQO\3HQWDLUDSSURYHGÀH[LEOH KRVHNLWV31IWDQG31IW 2FFDVLRQDOO\DWZRVSHHGSXPSZLOOQRWGHYHORSHQRXJKSUHVVXUHRQWKHORZVSHHGWRRSHUDWHWKHKHDWHU,QWKLVFDVHUXQ WKHSXPSDWKLJKVSHHGRQO\WRRSHUDWHWKHKHDWHU,IWKLVGRHVQRWVROYHWKHSUREOHPGRQRWWU\WRUXQWKHKHDWHU,QVWHDG FRUUHFWWKHLQVWDOODWLRQ 'RQRWRSHUDWHWKHKHDWHUZKLOHDQDXWRPDWLFSRROFOHDQHULVDOVRRSHUDWLQJ,IWKHFLUFXODWLRQSXPSVXFWLRQLVSOXJJHG IRUH[DPSOHE\OHDYHVWKHUHPD\QRWEHDGHTXDWHÀRZWRWKHKHDWHU'RQRWUHO\RQWKHSUHVVXUHVZLWFKLQWKLVFDVH MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions 13 VALVES :KHQDQ\HTXLSPHQWLVORFDWHGEHORZWKHVXUIDFHRIWKHSRRORUVSDYDOYHVVKRXOGEHSODFHGLQWKHFLUFXODWLRQSLSLQJ V\VWHPWRLVRODWHWKHHTXLSPHQWIURPWKHSRRORUVSD&KHFNYDOYHVDUHUHFRPPHQGHGWRSUHYHQWEDFNVLSKRQLQJ%DFN VLSKRQLQJLVPRVWOLNHO\WRRFFXUZKHQWKHSXPSVWRSVFUHDWLQJDSUHVVXUHVXFWLRQGLIIHUHQWLDO'R127VDQLWL]HWKH SRROE\SXWWLQJFKORULQHWDEOHWVRUVWLFNVLQWRWKHVNLPPHUV:KHQWKHSXPSLVRIIWKLVZLOOFDXVHDKLJKFRQFHQWUDWLRQ RIFKORULQHWRHQWHUWKHKHDWHUZKLFKFRXOGFDXVHFRUURVLRQGDPDJHWRWKHKHDWH[FKDQJHU CAUTION Exercise care when installing chemical feeders so as to not allow back siphoning of chemical into the heater, filters or pump. When chemical feeders are installed in the circulation of the piping system, make sure the feeder outlet line is down stream of the heater, and is equipped with a positive seal noncorrosive “Check Valve”, (P/N R172288), between the feeder and heater. MANUAL BY-PASS :KHUHWKHZDWHUÀRZUDWHH[FHHGVWKHPD[LPXP*30/30 DPDQXDOE\SDVVVKRXOGEHLQVWDOOHGDQGDGMXVWHG$IWHULQVWDOOLQJWKH YDOYHDGMXVWWKHYDOYHWREULQJWKHÀRZUDWHZLWKLQWKHDFFHSWDEOH UDQJH 7KHQ UHPRYH WKH YDOYH KDQGOH RU ORFN LW LQ SODFH WR DYRLG WDPSHULQJ6HH)LJXUH Model 125 Min. (GPM) (LPM) Max. (GPM) (LPM) * 20 (76) Warm water out 70 (265) * Do not exceed the maximum recommended flow rate for the connecting piping. Cool water in Table 1. See page 34 for Pressure Relief Valve Installations. 1. Set Manual By-Pass Valve. 2. Remove Handle. BELOW POOL INSTALLATION INLET FROM HEATER OUTLET TO POOL ,IWKHKHDWHULVEHORZZDWHUOHYHOWKHSUHVVXUHVZLWFKPXVWEHDG MXVWHG7KLVDGMXVWPHQWPXVWEHGRQHE\DTXDOL¿HGVHUYLFHWHFKQL FLDQ6HHIROORZLQJ&$87,21EHIRUHLQVWDOODWLRQ Figure 5. CAUTION BELOW OR ABOVE POOL INSTALLATION The water pressure switch is set in the factory at 3.00 PSI (± 0.75 PSI). This setting is for a heater installed at pool level. If the heater is to be installed more than 1’ above or below, the water pressure switch must be adjusted by a qualified service technician. See page 34, Figure 29. FLOW SWITCH If the heater is installed more than 5’ above the pool or more than 4’ below the pool level, you will be beyond the limits of the pressure switch and a flow switch must be installed. Locate and install the flow switch externally on the outlet piping from the heater, as close as possible to the heater. Connect the flow switch wires in place of the water pressure switch wires. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 14 Section 3. Installation Instructions GAS CONNECTIONS GAS LINE INSTALLATIONS %HIRUHLQVWDOOLQJWKHJDVOLQHEHVXUHWRFKHFNZKLFKJDVWKHKHDWHUKDVEHHQGHVLJQHGWREXUQ7KLVLVLPSRUWDQWEHFDXVH GLIIHUHQWW\SHVRIJDVUHTXLUHGLIIHUHQWJDVSLSHVL]HV7KHUDWLQJSODWHRQWKHKHDWHUZLOOLQGLFDWHZKLFKJDVWKHKHDWHULV GHVLJQHGWREXUQ7DEOHVKRZQRQSDJHVKRZZKLFKVL]HSLSHLVUHTXLUHGIRUWKHGLVWDQFHIURPWKHJDVPHWHUWRWKH KHDWHU7KHWDEOHLVIRUQDWXUDOJDVDWDVSHFL¿FJUDYLW\RIDQGSURSDQHDWDVSHFL¿FJUDYLW\RI :KHQVL]LQJJDVOLQHVFDOFXODWHWKUHHDGGLWLRQDOIHHWRIVWUDLJKWSLSHIRUHYHU\HOERZXVHG:KHQLQVWDOOLQJWKHJDV OLQHDYRLGJHWWLQJGLUWJUHDVHRURWKHUIRUHLJQPDWHULDOLQWKHSLSHDVWKLVPD\FDXVHGDPDJHWRWKHJDVYDOYHZKLFK PD\UHVXOWLQKHDWHUIDLOXUH The gas meter should be checked to make sure that it will supply enough gas to the heater and any other appliances that may be used on the same meter. The gas line from the meter will usually be of a larger size than the gas valve supplied with the heater. Therefore a reduction of the connecting gas pipe will be necessary. Make this reduction as close to the heater as possible. 7KHKHDWHUUHTXLUHVDJDVVXSSO\RIQRWOHVVWKDQ´FPZFDQGQRWPRUHWKDQ´FPZF*DVVXSSO\ SUHVVXUHVRXWVLGHRIWKLVUDQJHPD\UHVXOWLQLPSURSHUEXUQHURSHUDWLRQ$PLQLPXPÀRZLQJRUG\QDPLFLQOHWSUHVVXUH ZKLOHWKHKHDWHULVUXQQLQJRI´FPZFLVUHTXLUHGWRPDLQWDLQLQSXWUDWLQJZLWKQRPRUHWKDQD´SUHVVXUH GURSEHWZHHQVWDWLFDQGG\QDPLF7KHJDVVXSSO\PXVWEHLQVWDOOHGLQDFFRUGDQFHZLWKWKHNational Fuel Gas Code, ANSIZ223.1RUVWDQGDUGCSA B149.1Natural Gas and Propane Installation CodesDVDSSOLFDEOHDQGDOODSSOLFDEOHORFDO FRGHV,QVWDOODPDQXDOVKXWRIIYDOYHDQGDVHGLPHQWWUDSDQGXQLRQORFDWHGRXWVLGHWKHKHDWHUSDQHOVVHH)LJXUH'R QRWXVHDUHVWULFWLYHJDVFRFN7KHIROORZLQJPLQLPXPJDVSLSHVL]HVDUHUHFRPPHQGHGIRUQDWXUDOJDVVXSSO\SLSLQJ VHH7DEOHRQSDJH)RUORZSUHVVXUH/3JDVSLSHVL]HPD\EHUHGXFHGE\´ZLWKDPLQLPXPSLSHVL]HRI´ &KHFNIRUFRPSOLDQFHZLWKORFDOFRGHV 7KHKHDWHUDQGDQ\RWKHUJDVDSSOLDQFHVPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\SLSLQJV\VWHPGXULQJDQ\SUHVVXUH WHVWLQJRQWKDWV\VWHPJUHDWHUWKDQò36,7KHKHDWHUDQGLWVJDVFRQQHFWLRQPXVWEHOHDNWHVWHGEHIRUHSODFLQJWKH KHDWHULQRSHUDWLRQ'RQRWXVHÀDPHWRWHVWWKHJDVOLQH8VHVRDS\ZDWHURUDQRWKHUQRQÀDPPDEOHPHWKRG NOTE A manual main shut-off valve must be installed externally to the heater. WARNING DO NOT INSTALL THE GAS LINE UNION INSIDE THE HEATER CABINET. THIS WILL VOID YOUR WARRANTY. SEDIMENT TRAPS ,QVWDOO D VHGLPHQW WUDS DQG XQLRQ ORFDWHG RXWVLGH WKH KHDWHU SDQHOV LQ DFFRUGDQFH ZLWK 1DWLRQDO FRGH UHTXLUHPHQWV'RQRWXVHDUHVWULFWLYHJDVFRFN7KH VHGLPHQWWUDSVKDOOEHHLWKHUDWHH¿WWLQJZLWKDFDSSHG QLSSOHLQWKHERWWRPRXWOHWZKLFKFDQEHUHPRYHGIRU FOHDQLQJ DV VKRZQ LQ )LJXUH RU DQ RWKHU GHYLFH UHFRJQL]HG DV DQ HIIHFWLYH VHGLPHQW WUDS $OO JDV SLSLQJVKRXOGEHWHVWHGDIWHULQVWDOODWLRQLQDFFRUGDQFH ZLWKORFDOFRGHV 18–24" of 3/4" Manual Gas line from Shut-off Valve Valve 1" Dia. or larger (See "Recommended Pipe Sizes" Chart) Bell Reducer At least 9" Union At least 3" Sediment Trap Figure 6. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation 15 GAS PIPE SIZING STAGE TWO “LOW PRESSURE” GAS PIPE SIZING PIPE SIZING FOR GAS LINE CONNECTIONS MAXIMUM EQUIVALENT PIPE LENGTH (Ft.) Natural Gas at 1000 B.T.U. per Cubic Foot Propane Gas at 2500 B.T.U. per Cubic Foot 1/2” MODEL 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO NAT PRO 125 - 20’ 50’ 80’ 125’ 250’ 450’ 600’ - - - - - - Table 2. TESTING GAS PRESSURE %HIRUHRSHUDWLQJWKHKHDWHUWKHKHDWHUDQGLWVJDVFRQQHFWLRQVPXVWEHOHDNWHVWHG'R127XVHDQRSHQÀDPHWRWHVW IRUOHDNV7HVWDOOJDVFRQQHFWLRQVIRUOHDNVZLWKVRDS\ZDWHURUDQRWKHUQRQÀDPPDEOHPHWKRGVHHSDJH 7KHKHDWHUDQGLWVLQGLYLGXDOVKXWRIIYDOYHPXVWEHGLVFRQQHFWHGIURPWKHJDVVXSSO\SLSLQJV\VWHPGXULQJDQ\SUHVVXUH WHVWLQJRIWKDWV\VWHPDWWHVWSUHVVXUHVLQH[FHVVRISVLJN3D7KHKHDWHUPXVWEHLVRODWHGIURPWKHJDVVXSSO\ V\VWHPE\FORVLQJLWVLQGLYLGXDOPDQXDOVKXWRIIYDOYHGXULQJDQ\SUHVVXUHWHVWLQJRIWKHJDVVXSSO\DWWHVWSUHVVXUHV HTXDOWRRUOHVVWKDQSVLJN3D CHECKING THE GAS PRESSURE THROUGH THE COMBINATION GAS CONTROL VALVE WARNING Risk of fire and explosion. Improper installation, incorrect adjustment, alteration, service, or maintenance of the Combination Gas Control Valve can lead to fire or explosion, causing loss of life, personal injury, and/or property damage. If it is necessary to adjust the gas valve, this must be done by only by a qualified service agency. These instructions are for the use of qualified service technicians only! 7KLVDSSOLDQFHLVHTXLSSHGZLWKDQXQFRQYHQWLRQDOJDVFRQWUROYDOYHWKDWLVIDFWRU\VHWZLWKDPDQLIROGSUHVVXUHRI–.2´ ±FPZF,QVWDOODWLRQRUVHUYLFHPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHUVHUYLFHDJHQF\RUWKHJDVVXSSOLHU,I WKLVFRQWUROYDOYHLVUHSODFHGLWPXVWEHUHSODFHGZLWKDQLGHQWLFDOFRQWURO7KHFRPELQDWLRQJDVYDOYHLQFRUSRUDWHVGXDO VKXWRIIYDOYHVDQGDQHJDWLYHSUHVVXUHUHJXODWRU)RUSURSHURSHUDWLRQWKHUHJXODWHGSUHVVXUHDWWKHRXWOHWPDQLIROGRI WKHYDOYHPXVWEH±´±FPZFEHORZWKHUHIHUHQFHSUHVVXUHDWWKHEORZHUPL[HULQOHWDQGWKHJDVYDOYHµ9(17¶ WDSPXVWEHFRQQHFWHGWRWKHHQGFDSDLURUL¿FHDVVKRZQLQ)LJXUH'RQRWDWWHPSWWRDGMXVWWKHJDVLQSXWE\ To Air Flow Switch Connection for Service To Gas Valve Vent To Air Flow Switch Connection for Test To High Side of Differential Pressure Gauge To Gas Valve Vent Pressure Tap Inlet Vent Pressure Tap Figure 7. To Low Side of Differential Pressure Gauge GAS PRESSURE REQUIREMENTS CAUTION The use of Flexible Connectors (FLEX) is NOT recommended unless they are properly sized according to the supplier recommendations for the heater rating. Rev. B 8/14 MASTERTEMP® 125 HEATER GAS PRESSURE: NATURAL AND PROPANE: MAXIMUM INLET: 14 INCHES W.C. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 16 Section 3. Installation Instructions OUTDOOR INSTALLATION (U.S. and Canada) )RUKHDWHUVORFDWHGRXWGRRUVXVLQJWKHEXLOWLQVWDFNOHVVYHQWLQJV\VWHP WARNING Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do not install the heater using propane in pits or other locations where gas might collect. Consult your local building code officials to determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and filling equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquid Petroleum Gases, ANSI/NFPA 58 (latest edition) in the U.S., or CAN/CSA B149.2 (latest edition) in Canada. Consult local codes and fire protection authorities about specific installation restrictions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or Heater mounting bolts and clamps, purchase separately Bolt Down Bracket Kit, Part No. 460738. Lead Anchor HEATER CLEARANCES – OUTDOOR IMPORTANT! s )NANOUTDOORINSTALLATIONITISIMPORTANTTOENSUREWATERISDIVERTEDFROMOVERHANGING EVESWITHAPROPERGUTTERDRAINAGESYSTEM4HEHEATERMUSTBESETONALEVELFOUNDATION for proper drainage. s 4HISUNITSHALLNOTBEOPERATEDOUTDOORSATTEMPERATURESBELOWo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ft. (1 M) or more CAUTION If installing the heater next to or near an air conditioning unit or a heat pump, allow a minimum of 36 in. (91.4 cm) between the air conditioning unit and the heater. Figure 8. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions OUTDOOR INSTALLATION VENTING GUIDELINES 17 From window or door 4' 3' SIDE VIEW 4' Property Line 6 in 4' From building wall Force Air Inlet Exhaust Grill (Vent) es od g c nts. n i e ild m bu uire al oc k req l k ec bac Ch set for Building Vent Termination: Must be at least 3 ft. above any forced air inlet located within a 10 ft. radius. Must be located 6 in. away from the building wall and the following distances away from any building wall openings, included but not limited to vented eaves, doors, windows, gravity air inlet: 4 ft. below, 4 ft. horizontally Figure 9. INDOOR VENTING — General Requirements The heater may be installed as a Category I or Category III appliance. Vented Appliance (Category I) – Vertical only $QDSSOLDQFHWKDWRSHUDWHVZLWKDnonpositiveYHQWVWDWLFSUHVVXUHDQGZLWKDYHQWJDVWHPSHUDWXUHWKDWDYRLGVH[FHVVLYH FRQGHQVDWHSURGXFWLRQLQWKHYHQWVHHSDJHV Vented Appliance (Category III) – Vertical or Horizontal $QDSSOLDQFHWKDWRSHUDWHVZLWKDpositiveYHQWVWDWLFSUHVVXUHDQGZLWKDYHQWJDVWHPSHUDWXUHWKDWDYRLGVH[FHVVLYH FRQGHQVDWHSURGXFWLRQLQWKHYHQWVHHSDJHV ,I\RXDUHFRQVLGHULQJFRQQHFWLQJWKLVKHDWHUWRDSUHH[LVWLQJYHQWV\VWHPPDNHVXUHWKDWWKHYHQWV\VWHPPHHWVWKH DSSURSULDWHYHQWLQJUHTXLUHPHQWVDVJLYHQLQWKLVPDQXDORQSDJHV,IQRWUHSODFHWKHYHQWV\VWHP'2127XVH DGUDIWKRRGZLWKWKLVKHDWHU 7KH0DVWHU7HPS®KHDWHULVDUHFDSDEOHRIDGHJUHHGLVFKDUJHURWDWLRQDQGRSHUDWHZLWKDSRVLWLYHYHQWVWDWLF SUHVVXUHDQGZLWKDYHQWJDVWHPSHUDWXUHOHVVWKDQ)&7KHWRWDOOHQJWKRIWKHKRUL]RQWDOUXQPXVWQRW H[FHHGWKHOHQJWKWKDWLVOLVWHGLQ7DEOHRQSDJH Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 18 Section 3. Installation Instructions HEATER CLEARANCES — General Requirements INDOOR INSTALLATION (U.S.) OR OUTDOOR SHELTER (CANADA) 7KHIROORZLQJFOHDUDQFHVPXVWEHPDLQWDLQHGIURPFRPEXVWLEOHVXUIDFHV (*) For service access, it is advisable to allow for sufficient clearance on at least one door panel. TOP...............................6 in. (15 cm) 15 cm (6 in) EXHAUST SIDE ...........6 in. (15 cm) HEADER SIDE .............6 in. (15 cm) DOOR PANELS† .........6 in. (15 cm) 1RWH)RUVHUYLFHDFFHVVLWLVDGYLVDEOHWRDOORZIRUVXI¿FLHQWFOHDUDQFHRQ DWOHDVWRQHGRRUSDQHO7KHKHDWHULVGHVLJQFHUWL¿HGE\&6$,QWHUQDWLRQDO IRULQVWDOODWLRQRQFRPEXVWLEOHÀRRULQJ)RULQVWDOODWLRQRQFDUSHWLQJWKH KHDWHUPXVWEHPRXQWHGRQDPHWDORUZRRGSDQHOWKDWH[WHQGVDWOHDVWWKUHH LQFKHVFPEH\RQGWKHEDVHRIWKHKHDWHU,IWKHKHDWHULVLQVWDOOHGLQD FORVHWRUDOFRYHWKHHQWLUHÀRRUVKDOOEHFRYHUHGE\WKHSDQHO2QDQRXWGRRU VKHOWHULQVWDOODWLRQWKHH[KDXVWGLVFKDUJHVLQWRDYHQWSLSH2ULHQWWKHKHDWHU VRWKDWWKHYHQWSLSHGRHVQRWLQWHUIHUHZLWKDGMXVWPHQWRIWKHRSHUDWLQJ FRQWUROV7KHFRQWUROSDQHOORFDWHGRQWKHWRSSDQHOFDQEHURWDWHGWRDQ\ RIWKHWKUHHVLGHVRIWKHKHDWHUIRUHDV\DFFHVV+RZHYHUWKHFRQWUROSDQHO PXVWQRWEHORFDWHGRQWKHVLGHZKHUHWKHYHQWLVORFDWHGVHH)LJXUH 15 cm* (6 in) 15 cm* (6 in) 15 cm (6 in) Figure 10. OUTSIDE VENT COVER REMOVAL 7KHKHDWHULVVXSSOLHGIURPWKHIDFWRU\ZLWKDEXLOWLQVWDFNOHVVRXWVLGHYHQWIRURXWGRRU LQVWDOODWLRQ5HPRYHWKHRXWVLGHYHQWFRYHUIRURXWGRRUVKHOWHULQVWDOODWLRQ Air Supply Requirements Guide for MasterTemp® 125 Heater COMBUSTION AIR SUPPLY )RULQGRRULQVWDOODWLRQWKHKHDWHUORFDWLRQPXVWSURYLGH VXI¿FLHQWDLUVXSSO\IRUSURSHUFRPEXVWLRQDQGYHQWLODWLRQ RIWKHVXUURXQGLQJDUHD 7KHPLQLPXPUHTXLUHPHQWVIRUWKHDLUVXSSO\VSHFLI\WKDW WKHURRPLQZKLFKDKHDWHULVLQVWDOOHGVKRXOGEHSURYLGHG ZLWKWZRSHUPDQHQWDLUVXSSO\RSHQLQJVRQHZLWKLQ LQFKHVFPRIWKHFHLOLQJWKHRWKHUZLWKLQLQFKHV FPRIWKHÀRRUIRUFRPEXVWLRQDLULQDFFRUGDQFHZLWK WKH ODWHVW HGLWLRQ RI$16, = RU WKH 1DWLRQDO )XHO *DV FRGH WKH &6$ % 1DWXUDO *DV DQG 3URSDQH ,QVWDOODWLRQ&RGHVDVDSSOLFDEOHDQGDQ\ORFDOFRGHVWKDW PD\DSSO\7KHVHRSHQLQJVVKDOOGLUHFWO\RUWKURXJKGXFW FRQQHFWWRRXWGRRUDLU Minimum Net Free Open Area for Each Opening* (Square Inches/Centimeters) All Air From Inside Building All Air From Outside Building Model 125 Combustion Vent Combustion Vent 200 sq. in. 1290 sq. cm. 200 sq. in. 1290 sq. cm. 50 sq. in. 323 sq. cm. 50 sq. in. 323 sq. cm. * Area indicated is for one of two openings; one at floor level and one at the ceiling. Table 3. 1RWH)RULQGRRULQVWDOODWLRQVZKHUHFRPEXVWLRQ DLU PLJKW EH LQVXI¿FLHQW VHH ³'LUHFW$LU ,QWDNH 'XFWZLWKLQFK39&3LSH,QGRRU,QVWDOODWLRQ´ RQSDJH MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions 19 $IRECT!IR)NTAKE$UCTWITHINCH06#0IPE)NDOOR)NSTALLATION )RULQGRRUKHDWHULQVWDOODWLRQVZKHUHFRPEXVWLRQDLUVXSSO\PLJKWEHLQVXI¿FLHQWWKH0DVWHU7HPS®+HDWHULV FHUWL¿HGIRUDGLUHFWDLULQWDNHGXFWXVLQJLQFK39&SLSH,IRXWVLGHDLULVGUDZQWKURXJK´39&GXFWGLUHFWO\LQWRWKH KHDWHU39&SLSHFDQEHLQVWDOOHGLQDFFRUGDQFHZLWKWKHIROORZLQJUHTXLUHPHQWV 7KHDLULQWDNHRSHQLQJ0867EHLQVWDOOHGDWOHDVWIWDERYHWKHURRIOLQHRUQRUPDOVQRZOHYHOVIRUIUHHDLUÀRZ7KH &DWHJRU\,RU,,,H[KDXVWYHQWWHUPLQDWLRQFDSPXVWKDYHDWOHDVWIWPLQLPXPYHUWLFDOFOHDUDQFHIURPDLULQWDNHGXFW 6HH)LJXUHEHORZ Combustion 3 in. PVC Pipe Inlet Air Intake Duct Requirements* Combustion Air Intake 3 in. Pipe (Vertical or Horizontal) No. of 90° Elbows 0 1 2 3 4 Maximum Length in Feet (M) 70 ft. (21.3 M) 58 ft. (17.7 M) 46 ft. (14.0 M) 34 ft. (10.4 M) 22 ft. ( 6.7 M) Table 4. WARNING! DO NOT USE PVC PIPE FOR FLUE EXHAUST VENT. FLUE EXHAUST VENT TEMPERATURES CAN BE IN EXCESS OF 400° F. FLUE EXHAUST VENT MUST BE CATEGORY I or CATEGORY III METAL VENT. Figure 11. Note (*): Combustion Air Intake Duct Connection Kit (Call 1.800.831.7133 for part number) for all MasterTemp® 125 Heater models can be purchased separately. See page 52 for parts list. NOTE Each 90-degree elbow reduces the maximum horizontal PVC air intake duct run by 12 feet and each 45-degree elbow in the PVC air intake duct run reduces the maximum run by 6 feet. See the Table 5 above for the maximum lengths using 90-degree elbows. Corrosive Vapors and Possible Causes Area Likely Contaminants Chlorinated swimming pools and spas Pool or spa cleaning chemicals. Acids, such as hydrochloric or muriatic acid. New construction and remodeling areas Glues and cements, construction adhesives, paints, varnishes, and paint and varnish strippers. Waxes and cleaners containing calcium or sodium chloride. CAUTION Chemicals should not be stored near the heater installation. Combustion air can be contaminated by corrosive chemical fumes which can void the warranty. Table 5. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 20 Section 3. Installation Instructions VENT INSTALLATION – INDOOR INSTALLATION (U.S.) OR OUTDOOR SHELTER (CANADA) (Category I) NOTE *: Vent must be at least eight (8) feet away from nearest vertical surface. Vents extending five (5) feet or more above the roof must be braced or guyed. Consult your local code officials for detailed information. $OZD\VYHQWWKHKHDWHUWRWKHRXWGRRUVVHH1RWH 9HQWLWYHUWLFDOO\XVLQJ7\SH³%´GRXEOHZDOOYHQWFRQQHFWRUSLSH /RFDWHWKHKHDWHUVRDVWRPLQLPL]HWKHOHQJWKRIKRUL]RQWDOYHQWLQJDQGWKHQXPEHURIYHQWHOERZVUHTXLUHG+RUL]RQWDO YHQWUXQVPXVWVORSHXS´SHUIRRWFP0IURPWKHKHDWHUWRDOORZH[KDXVWFRQGHQVDWHWRGUDLQDQGLWLVUHFRPPHQGHG WRKDYHDFRQGHQVDWHGUDLQDVGHVFULEHGLQWKHYHQWLQJLQVWDOODWLRQLQVWUXFWLRQV VERTICAL VENTING - NEGATIVE PRESSURE (See Figures 12, 13 and 14) 9HQW WKH KHDWHU YHUWLFDOO\ LQ D QHJDWLYH SUHVVXUH SRVLWLYH GUDIW V\VWHP LQ DFFRUGDQFHZLWKWKH1DWLRQDO)XHO*DV&RGH$16,=1)3$DQGRU&6$ %1DWXUDO*DVDQG3URSDQH,QVWDOODWLRQ&RGHVDQGORFDOFRGHV7\SH³%´ 'RXEOHZDOOYHQWFRQQHFWRULVUHFRPPHQGHGKRZHYHUVLQJOHZDOOSLSHLVDOORZHG E\WKH1DWLRQDO)XHO*DV&RGHLQVRPHFLUFXPVWDQFHV&RQVXOW\RXUORFDOFRGH RI¿FLDOIRUGHWDLOHGLQIRUPDWLRQ'RQRWXVHDGUDIWKRRGZLWKWKLVKHDWHU Clean the Interior Surface Vent Body V 4" x 8" Metal Flue Collar Vent Pipe 7RFRQQHFWDQHJDWLYHSUHVVXUHPHWDOJDVYHQWWRWKHKHDWHURUGHUWKHDSSURSULDWH 0HWDO)OXH&ROODUIURPWKHFKDUWEHORZ Metal Flue Collar Part No. 4 x 6” 77707-0076 4 x 8” 77707-0077 Combustion Chamber Flue Collar Clean and RTV This Surface Figure 12. 6HH7DEOHWRGHWHUPLQHDOORZDEOHYHQWVL]HVIRU\RXUKHDWHU NOTICE:7DEOHLVIRULQVWDOODWLRQVLQZKLFKWKHWRWDOODWHUDOYHQWOHQJWKWKDWLVWKHKRUL]RQWDOGLVWDQFHIURPWKHÀXH FROODUWRWKHPDLQYHUWLFDOSRUWLRQRIWKHYHQWLVOHVVWKDQWKHWRWDOYHQWKHLJKWWKHYHUWLFDOGLVWDQFHIURPWKHÀXHFROODU WRWKHYHQWWHUPLQDWLRQDQGZKLFKKDYHWKUHHRUOHVVHOERZVLQWKHV\VWHP)RUYHQWLQJV\VWHPVZKLFKGRQRWPHHWWKHVH FRQGLWLRQVFRQVXOWWKH1DWLRQDO)XHO*DV&RGH$16,=86RUWKHVWDQGDUGV&6$%DQG%&DQDGD Read “VERTICAL VENTING – NEGATIVE PRESSURE” before using this table. Table 5. – Permitted Minimum and Maximum Vent Heights By Size and Heater Model Type "B" Double-Wall Vent with Type "B" Double-Wall Connector in Feet (Meters) Vent Size Model 125 Height min./max. 6 in. 6 ft. (1.8)/100 ft. (30.5) 7 in. 6 ft. (1.8)/100 ft. (30.5) 8 in. 6 ft. (1.8)/100 ft. (30.5) 9 and 10 in. 6 ft. (1.8)/50 ft. (15.3) Type "B" Double-Wall Vent with Single-Wall Connector in Feet (Meters) Model 125 Vent Size Height min./max. 6 in. 6 ft. (1.8)/15 ft. (4.6) 7 in. 6 ft. (1.8)/8 ft. (2.4) 8 in. Not Rec. 9 in. Not Rec. 10 in. Not Rec. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions 21 NOTE The allowable vent runs for each vent pipe diameter are different and can not be exceeded. Each 90-degree elbow reduces the maximum horizontal vent run by 12 feet and each 45-degree elbow in the vent run reduces the maximum vent run by 6 feet. See Table 5 on page 20 for the maximum vent lengths using 90-degree and 45-degree elbows. ,QVWDOO WKH PHWDO )OXH &ROODU LQ WKH 9HQW %RG\ RI WKH KHDWHUORFDWHGXQGHUWKHRXWVLGHYHQWFRYHU)DVWHQWKH PHWDO)OXH&ROODUWRWKH9HQW%RG\ZLWKWZRVKHHW PHWDOVFUHZV8VHKLJKWHPSHUDWXUHVLOLFRQH579WRVHDO WKH)OXH&ROODUWRWKH9HQW%RG\%HIRUHFRQQHFWLQJWKH PHWDO)OXH&ROODUWRWKH9HQW%RG\ZHWDFOHDQFORWKRU SDSHUWRZHOZLWKLVRSURS\ODOFRKROUXEELQJDOFRKRODQG YLJRURXVO\ZLSHWKHVRFNHWRIWKH9HQW%RG\,PPHGLDWHO\ ZLSHWKHFOHDQHGVXUIDFHVGU\ZLWKDFOHDQFORWKRUSDSHU WRZHO5HSHDWIRUWKHH[WHULRURIWKH´HQGRIWKHPHWDO )OXH&ROODU$WWDFKWKHPHWDO)OXH&ROODUWRWKH9HQW%RG\ XVLQJWKH579VXSSOLHGZLWKWKHNLWIROORZLQJWKHYHQW PDQXIDFWXUHU¶VLQVWUXFWLRQVLQFOXGHGZLWKNLW $WWDFKWKHYHQWSLSHWRWKHPHWDO)OXH&ROODUZLWKVKHHW PHWDOVFUHZV WARNING Risk of fire or asphyxiation if vent is not assembled according to manufacturer’s instructions or if vent parts from different manufacturers are mixed. Vent parts from different manufacturers ARE NOT interchangeable. Mixing parts from more than one manufacturer may cause leaks or damage to vent. When assembling a vent, pick one manufacturer and be sure that all vent parts come from that manufacturer and are specified by the manufacturer for your system. Follow manufacturer’s instructions, local code requirements, National Fuel Gas Code requirements (U.S.) or standards CSA B149.1 and B149.2 (Canada) carefully during assembly and installation. Listed Termination Cap Min. 10 Ft. Storm Collar Flashing 6" Minimum Clearance to Combustible Materials Class B Double Wall Metal Vent Pipe Vent Body Firestop Metal Flue Collar Support Vertical Vent Pipe so adapter does not take weight of pipe. Figure 13. – Typical Metal Vent Pipe Installation - U.S. (Vertical – Negative Pressure) Min. 2 Ft. (.7 M) Approved Termination Cap Min. 10 Ft. (3.3 M) Storm Collar Flashing 6" (15 cm) Minimum Clearance to Combustible Materials Double Wall Metal Vent Pipe Vent Body Metal Flue Collar Condensate Drain w/trap Firestop Double Wall Metal Vent Tee Support Vertical Vent Pipe so adapter does not take weight of pipe. Dispose of condensate according to local codes. Figure 14. – Typical Metal Vent Pipe Installation Canada (Vertical – Negative Pressure) Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 22 Section 3. Installation Instructions ,QVWDOOYHQWSLSHVRWKDWLWFDQH[SDQGDQGFRQWUDFWIUHHO\DVWKHWHPSHUDWXUHFKDQJHV6XSSRUWWKHYHQWSLSHDFFRUGLQJ WRDSSOLFDEOHFRGHVDQGWKHYHQWPDQXIDFWXUHU¶VLQVWUXFWLRQV3LSHVXSSRUWPXVWDOORZWKHYHQWSLSHIUHHPRYHPHQWRXW DQGEDFNIURPVLGHWRVLGHRUXSDQGGRZQDVQHFHVVDU\ZLWKRXWSXWWLQJDVWUDLQRQWKHKHDWHURUYHQWERG\6ORSH KRUL]RQWDOSLSHUXQVXSIURPWKHKHDWHUDWOHDVW´SHUIRRWFPSHUPHWHU,QVWDOO/LVWHGFRQGHQVDWHGUDLQVDWORZ SRLQWVZKHUHFRQGHQVDWHPLJKWFROOHFW3OXPEFRQGHQVDWHGUDLQVWRDGUDLQWKURXJKKDUGSLSLQJRUKLJKWHPSHUDWXUH WXELQJVXFKDVVLOLFRQHUXEEHURU(3'0UXEEHU±GRQRWXVHYLQ\ORURWKHUORZWHPSHUDWXUHWXELQJ)ROORZGUDLQ PDQXIDFWXUHU¶VLQVWDOODWLRQLQVWUXFWLRQV 8VH/LVWHG¿UHVWRSIRUÀRRUDQGFHLOLQJSHQHWUDWLRQV8VH/LVWHGWKLPEOHIRUZDOOSHQHWUDWLRQV8VHD/LVWHGURRI ÀDVKLQJURRIMDFNRUURRIWKLPEOHIRUDOOURRISHQHWUDWLRQV'RQRW¿OOWKHVSDFHDURXQGWKHYHQWWKDWLVWKHFOHDU DLUVSDFHLQWKHWKLPEOHRU¿UHVWRSZLWKLQVXODWLRQ7KHURRIRSHQLQJPXVWEHORFDWHGVRWKDWWKHYHQWLVYHUWLFDO 'RQRWUXQWKHKHDWHUYHQWLQWRDFRPPRQYHQWZLWKDQ\RWKHUDSSOLDQFH WARNING Fire Hazard. Do not vent the heater directly into a masonry chimney. Installation into a masonry chimney must use a chimney liner and must meet the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Codes requirements and all local code requirements. WARNING Risk of fire, carbon monoxide poisoning, or asphyxiation. It is recommended to use a CO Monitor and Fire Alarm in rooms that contain gas fired appliances. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions 23 HORIZONTAL OR VERTICAL VENTING - POSITIVE PRESSURE (See Figures 15, 16, and 17) (Category III) 9HQW WKH KHDWHU HLWKHU KRUL]RQWDOO\ RU YHUWLFDOO\ XVLQJ DQ RSWLRQDO YHQW DGDSWHU RI WKH LQFK VSHFLDO JDV DSSURYHG &DWHJRU\,,,YHQWSLSHV,QVWDOOWKHYHQWSLSHLQDFFRUGDQFHZLWKORFDOFRGHVDQGWKHSURYLVLRQVRIWKH1DWLRQDO)XHO *DV&RGH$16,=86RUWKHVWDQGDUGV&6$%1DWXUDO*DVDQG3URSDQH,QVWDOODWLRQ&RGHV&DQDGD DQG WKH YHQW PDQXIDFWXUHU¶V LQVWUXFWLRQV 'R QRW XVH D GUDIW KRRG ZLWK WKLV KHDWHU ,QVWDOO WKH YHQW DFFRUGLQJ WR WKH YHQW PDQXIDFWXUHU¶V GHWDLOHG LQVWUXFWLRQV 1RWH 0DLQWDLQFOHDUDQFHEHWZHHQWKHYHQWSLSHDQGFRPEXVWLEOHVXUIDFHV DFFRUGLQJWRWKHYHQWPDQXIDFWXUHU¶VLQVWUXFWLRQVDQGFRGHUHTXLUHPHQWV'RQRWSODFHDQ\LQVXODWLQJPDWHULDOVDURXQG WKHYHQWRULQVLGHWKHUHTXLUHGFOHDUDLUVSDFHVXUURXQGLQJWKHYHQW6HH7DEOHIRUPD[LPXPSHUPLVVLEOHYHQWOHQJWKV NOTE The allowable vent runs for each vent pipe diameter are different and can not be exceeded. Each 90° elbow reduces the maximum horizontal vent run by 12 feet and each 45-degree elbow in the vent run reduces the maximum vent run by 6 ft. See the Table 6 below for the maximum vent lengths using 90° elbows. 7KH0DVWHU7HPSKHDWHULVD³&DWHJRU\,,,´DSSOLDQFH ZKLFKUHTXLUHVDIRXULQFKVSHFLDOJDVDSSURYHG³&DWHJRU\ ,,,´YHQWSLSHDQGLVDIRUFHGGUDIWSRRODQGVSDKHDWHUZKLFK XVHVSRVLWLYHSUHVVXUHWRSXVKÀXHJDVHVWKURXJKWKHYHQWSLSHWR WKHRXWVLGH)OXHJDVHVXQGHUSRVLWLYHSUHVVXUHPD\HVFDSHLQWR WKHGZHOOLQJZLWKDQ\FUDFNVRUORRVHMRLQWVLQWKHYHQWSLSH RULPSURSHUYHQWLQVWDOODWLRQ7KHYHQWSLSHPXVWEHRIDVHDOHG VHDPFRQVWUXFWLRQVXFKDVWKRVHOLVWHGIRUXVHZLWK³&DWHJRU\ ,,,$SSOLDQFHV´DQGIRURSHUDWLQJWHPSHUDWXUHVOHVVWKDQ) &9HQWSLSHFRQVWUXFWLRQZLOOEHRI8/DSSURYHGQRQ FRUURVLYHPDWHULDOVXFKDVVWDLQOHVVVWHHODOXPLQXPJDOYDQL]HG$ FRQGHQVDWHWUDSPD\EHQHHGHG7KHXVHRI³$SSURYHG´WKLPEOHV URRIMDFNVDQGRUVLGHYHQWWHUPLQDOVDUHUHTXLUHGDQGWKHSURSHU FOHDUDQFHVWRFRPEXVWLEOHPDWHULDOVPXVWEHPDLQWDLQHGLQ DFFRUGDQFHZLWKW\SHRIYHQWSLSHHPSOR\HG²LQWKHDEVHQFHRI DFOHDUDQFHUHFRPPHQGDWLRQE\WKHYHQWSLSHPDQXIDFWXUHUWKH UHTXLUHPHQWVRIWKH8QLIRUP0HFKDQLFDO&RGHVKRXOGEHPHW7KH YHQWLODWLRQDLUUHTXLUHPHQWVIRUWKH0DVWHU7HPS®KHDWHU DUHVKRZQRQSDJH.,WLVUHFRPPHQGHGWKDWYHQWUXQVRYHUIHHW PD\QHHGWREHLQVXODWHGWRUHGXFHFRQGHQVDWLRQUHODWHGSUREOHPVDQG RUWKHXVHRIDFRQGHQVDWHWUDSLQWKHYHQWUXQFORVHWRWKHKHDWHUPD\EH QHFHVVDU\LQFHUWDLQLQVWDOODWLRQVVXFKDVFROGFOLPDWHV+RUL]RQWDO YHQWV¶0RUOHVVLQOHQJWKGRQRWUHTXLUHDFRQGHQVDWHWHH7KH 0DVWHU7HPSKHDWHULVVXLWDEOHIRUWKURXJKWKHZDOOYHQWLQJ 4 in. Special Gas Vent (Vertical or Horizontal) No. of 90° Elbows 0 1 2 3 4 Maximum Length in Feet (M) 70 ft. (21.3 M) 58 ft. (17.7 M) 46 ft. (14.0 M) 34 ft. (10.4 M) 22 ft. ( 6.7 M) Table 6. *Minimum vent length is one foot (.34M), or in accordance with vent manufacturer’s instruction, and local and national codes. Horizontal vents 3’(1M) or less in length do not require a condensate tee, but must slope down toward the outlet at 1/4” to the foot (2cm/M) to allow condensate to drain. CAUTION Do NOT combine exhaust vent pipes to a common exhaust vent in multiple unit installations. Run separate vent pipes. CONNECTING SPECIAL METALIC GAS VENT TO THE HEATER 2UGHUDQRSWLRQDODSSOLDQFHDGDSWHUNLW(3HQWDLURIIHUVRSWLRQDODSSOLDQFHDGDSWHUNLWVFDOO&XVWRPHU6HUYLFHDW IRUPRUHLQIRUPDWLRQ3DUW1RIRU6DI79HQWRU6DI79HQW&,3DUW1R IRU=9HQW 5HPRYHWKHRXWVLGHYHQWFRYHU ,QVWDOOWKH$SSOLDQFH$GDSWHULQWKH9HQW%RG\RIWKHKHDWHUORFDWHGXQGHUWKHRXWVLGH9HQW&RYHU%HIRUH FRQQHFWLQJWKH$SSOLDQFH$GDSWHUWRWKH9HQW%RG\ZHWDFOHDQFORWKRUSDSHUWRZHOZLWKLVRSURS\ODOFRKRO UXEELQJDOFRKRODQGYLJRURXVO\ZLSHWKHVRFNHWRIWKH9HQW%RG\,PPHGLDWHO\ZLSHWKHFOHDQHGVXUIDFHVGU\ ZLWKDFOHDQFORWKRUSDSHUWRZHO5HSHDWIRUWKHH[WHULRURIWKHKHDWHUHQGRIWKH$SSOLDQFH$GDSWHU$WWDFKWKH DSSOLDQFHDGDSWHUWRWKHYHQWERG\XVLQJWKHDGKHVLYHVSHFL¿HGE\WKHYHQWPDQXIDFWXUHUIROORZLQJWKHYHQW PDQXIDFWXUHU¶VLQVWUXFWLRQV Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 24 Section 3. Installation Instructions WARNING Risk of carbon monoxide poisoning if adapter is improperly attached. Mechanical connections (such as screws) can cause cracking and leaks in the adapter. Do NOT drill holes or use screws to connect the appliance adapter to the heater vent body. Attach with manufacturer’s specified adhesive. WARNING Risk of fire or asphyxiation if vent is not assembled according to manufacturer’s instructions or if vent parts from different manufacturers are mixed. Vent parts from different manufacturers ARE NOT interchangeable. Mixing parts from more than one manufacturer may cause leaks or damage to vent. When installing a vent, pick one manufacturer and be sure that all vent parts come from that manufacturer and are specified by the manufacturer for your system. Follow manufacturer’s instructions and local and National Fuel Gas Code (U.S.) or CSA B149.1, Natural Gas and Propane Installation Codes (Canada) requirements carefully during assembly and installation. ,QVWDOOYHQWSLSHVRWKDWLWFDQH[SDQGDQGFRQWUDFWIUHHO\DV WKHWHPSHUDWXUHFKDQJHV6XSSRUWWKHYHQWSLSHDFFRUGLQJ WR DSSOLFDEOH FRGHV DQG YHQW PDQXIDFWXUHU¶V LQVWUXFWLRQV 3LSHVXSSRUWPXVWDOORZWKHYHQWSLSHIUHHPRYHPHQWRXW DQGEDFNIURPVLGHWRVLGHRUXSDQGGRZQDVQHFHVVDU\ ZLWKRXW SXWWLQJ D VWUDLQ RQ WKH KHDWHU RU YHQW ERG\ ,W LV UHFRPPHQGHGWRVORSHWKHKRUL]RQWDOSLSHUXQVXSIURPWKH KHDWHU DW OHDVW ´ SHU IRRW FP0 ,QVWDOO ³$SSURYHG´ FRQGHQVDWH GUDLQV DW ORZ SRLQWV ZKHUH FRQGHQVDWH PLJKW FROOHFW 3OXPE FRQGHQVDWH GUDLQV WR D GUDLQ WKURXJK KDUG SLSLQJRUKLJKWHPSHUDWXUHWXELQJVXFKDVVLOLFRQHUXEEHURU (3'0UXEEHU±GRQRWXVHYLQ\ORURWKHUORZWHPSHUDWXUH WXELQJ)ROORZGUDLQPDQXIDFWXUHU¶VLQVWDOODWLRQLQVWUXFWLRQV 8VHDQ³$SSURYHG´¿UHVWRSIRUÀRRUDQGFHLOLQJSHQHWUDWLRQV 8VHDQ³$SSURYHG´WKLPEOHIRUZDOOSHQHWUDWLRQV8VHDQ ³$SSURYHG´ URRI ÀDVKLQJ URRI MDFN RU URRI WKLPEOH IRU DOOURRISHQHWUDWLRQV'RQRW¿OOWKHVSDFHDURXQGWKHYHQW WKDWLVWKHFOHDUDLUVSDFHLQWKHWKLPEOHRU¿UHVWRSZLWK LQVXODWLRQ7KHURRIRSHQLQJPXVWEHORFDWHGVRWKDWWKHYHQW LVYHUWLFDO 9HQW7HUPLQDWLRQ±9HUWLFDO6HH)LJXUHVDQGIRU KHLJKWRIYHQWWHUPLQDWLRQDERYHWKHURRI8VHDQ³$SSURYHG´ YHQW WHUPLQDO VSHFL¿HG E\ ORFDO DQG QDWLRQDO FRGHV DQG \RXUPDQXIDFWXUHU¶VLQVWUXFWLRQV$URRIWHUPLQDWLRQPXVW EH YHUWLFDO ,Q &DQDGD WKH 9HQW &DS ORFDWLRQ VKDOO KDYH D PLQLPXP FOHDUDQFH RI IHHW 0 KRUL]RQWDOO\ IURP HOHFWULFPHWHUVJDVPHWHUVUHJXODWRUVDQGUHOLHIRSHQLQJV Chimney or Gas Vent Vent Cap and Riser Furnished by Installer Outlet Air Opening Side Wall Vent Inlet Air Opening Figure 15. Chimney or Gas Vent Vent Cap and Riser Furnished by Installer Outlet Air Opening 0DNHVXUHHQWLUHLQVWDOODWLRQLVVHDOHGDFFRUGLQJWRDSSURYHG VWDQGDUG Side Wall Vent Inlet Air Opening Heater Figure 16. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions 25 4' Min. Vent Termination Vent Termination 4' Min. Vent Termination 1' Min. 4' Min. 1' Minimum above snow or finished grade (whichever is higher) Max. 12" Min. 3" 4' Min. At least 7' above grade adjacent to public walkways Gas Meter Forced Air Inlet 3' Minimum clearance if horizontal distance to exhaust opening is less than 10 feet. Figure 17. 9HQW7HUPLQDWLRQ±+RUL]RQWDO 7KHWHUPLQDOPXVWEHORFDWHG86±6HH)LJXUH DWOHDVW´DQGDWPRVW´RXWIURPWKHZDOOVHH)LJXUHIROORZLQJWKHYHQWPDQXIDFWXUHU¶VLQVWUXFWLRQV DWOHDVW´DERYH¿QLVKHGJUDGHRUWKHQRUPDOO\H[SHFWHGVQRZDFFXPXODWLRQOHYHOZKLFKHYHULVKLJKHU DWOHDVWIHHWEHORZRUKRUL]RQWDOO\IURPRUIRRWDERYHDQ\GRRUVRUZLQGRZVRUJUDYLW\DLULQOHWWRDEXLOGLQJ DWOHDVWIHHWDERYHDQ\IRUFHGDLULQOHWORFDWHGZLWKLQIHHW DWOHDVWIHHWKRUL]RQWDOO\IURPHOHFWULFPHWHUVJDVPHWHUVUHJXODWRUVDQGUHOLHIHTXLSPHQW DWOHDVWIHHWDERYHJUDGHDGMDFHQWWRZDONZD\VRUVLPLODUWUDI¿FDUHDV 7KHWHUPLQDOPXVWEHORFDWHG&DQDGD±6HH)LJXUH DWOHDVWIHHW0IURPDQ\RSHQLQJLQWRDEXLOGLQJ DWOHDVW´0DERYH¿QLVKHGJUDGHRUWKHQRUPDOO\H[SHFWHGVQRZDFFXPXODWLRQOHYHOZKLFKHYHULVKLJKHU DWOHDVWIHHW0KRUL]RQWDOO\IURPHOHFWULFPHWHUVJDVPHWHUVUHJXODWRUVDQGUHOLHIHTXLSPHQW DWOHDVWIHHW0DERYHJUDGHDGMDFHQWWRZDONZD\VRUVLPLODUWUDI¿FDUHDV $OORZ DW OHDVW WKUHH IHHW 0 YHUWLFDO FOHDUDQFH RYHU YHQW WHUPLQDWLRQ ZKHQ WHUPLQDWLQJ XQGHU DQ RYHUKDQJ $YRLGFRUQHUVRUDOFRYHVZKHUHVQRZRUZLQGFRXOG KDYH DQ HIIHFW ([KDXVW PD\ DIIHFW VKUXEEHU\ DQG VRPHEXLOGLQJPDWHULDOV.HHSVKUXEEHU\DZD\IURP WHUPLQDWLRQ 7R SUHYHQW VWDLQLQJ RU GHWHULRUDWLRQ VHDOLQJ RU VKLHOGLQJ H[SRVHG VXUIDFHV PD\ EH UHTXLUHG WARNING Fire Hazard. Do not run the heater vent into a common vent with any other appliance. Do not run the Special Gas Vent into, through, or within any active vent such Metal Special Support Gas Vent weight requires of pipe Appliance Adapter Condensate Tee Listed Terminal Metal Vent Body Condensate drain w/Trap (Optional) Slope at least 1/4" per foot (2 cm per Meter) down towards condensate drain 3" (7.6 cm) Min., 12" (30.5 cm) Ma Clearance Figure 18. Rev. B 8/14 ® MASTERTEMP 125 Pool and Spa Heater Installation and User’s Guide 26 Section 3. Installation Instructions OUTDOOR SHELTER INSTALLATION ,Q&DQDGDWKLVSRROKHDWHUFDQRQO\EHLQVWDOOHGRXWGRRUVRULQDQHQFORVXUHWKDWLVQRWQRUPDOO\RFFXSLHGDQGKDVQR GLUHFWRSHQLQJVLQWRRFFXSLHGDUHDV WARNING Risk of asphyxiation if exhaust is not correctly vented. Follow venting instructions exactly when installing heater. Do not use a draft hood with this heater, as the exhaust is under pressure from the burner blower and a draft hood will allow exhaust fumes to blow into the room housing the heater. Exhaust venting to the outdoors is required for all outdoor shelter installations. WARNING Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do not install the heater using propane in pits or other locations where gas might collect. Consult your local building code officials to determine installation requirements and specific installation restrictions of the heater relative to propane storage tanks and filling equipment. Installation must meet the requirements for the Standard for the Storage and Handling of Liquefied Petroleum Gases, CAN/CSA B149.2 (latest edition) or ANSI/NFPA 58 (latest edition). Consult local codes and fire protection authorities about specific installation restrictions. 7KHKHDWHULVGHVLJQFHUWL¿HGE\&6$,QWHUQDWLRQDOIRULQVWDOODWLRQRQFRPEXVWLEOHÀRRULQJLQDOFRYHVEDVHPHQWVLQ FORVHWRUXWLOLW\URRPVLQWKH86 GARAGE OR UTILITY ROOM INSTALLATION ,Q&DQDGDWKHKHDWHUPXVWEHLQVWDOOHGLQDURRPWKDWLVQRWQRUPDOO\RFFXSLHGDQGKDVQRRSHQLQJV GLUHFWO\WRRFFXSLHGDUHDV WARNING Risk of fire and explosion if installed at floor level in an automotive garage or near gasoline or flammable liquid storage. Gasoline fumes are heavier than air and will settle to floor level in closed spaces. Gasoline fumes and spilled gasoline or other volatile liquids (such as some paints and varnishes) will travel across the floor and can be ignited by a gas appliance. ,QDQ\XWLOLW\URRPRUUHVLGHQWLDOJDUDJHLQVWDOODWLRQLQVWDOOWKHKHDWHUZLWKWKHEDVHDWOHDVWLQFKHV0DERYHWKH ÀRRUVHH)LJXUH,QDJDUDJHLQVWDOODUDLORUZDOOWRSURWHFWWKHKHDWHUIURPSK\VLFDOGDPDJHE\DPRYLQJYHKLFOH 3URYLGHDQDGHTXDWHYHQWLODWLRQDLUVXSSO\6HH7DEOHSDJH&KRRVHDORFDWLRQWKDWZLOODYRLGFRQWDPLQDWLRQ E\FKHPLFDOIXPHV Leave 3 ft. (1 m) or more of clearance above heater CAUTION A Propane (LPG) fired heater must not be installed in a garage in Massachusetts, by order of the Massachusetts State Fire Marshal. For more information, call the Massachusetts State Fire Marshal’s office. 127,&(&RPEXVWLRQDLUFRQWDPLQDWHGE\FRUURVLYHFKHPLFDOIXPHV FDQGDPDJHWKHKHDWHUDQGZLOOYRLGWKHZDUUDQW\ 6HH7DEOHSDJH Leave 6 in. (15 cm) of clear space between heater and combustible surface. RAISE AT LEAST 18 in. (46 cm) above floor 18 in. to avoid flammable vapors Figure 19. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions 27 CONTROL PANEL INDEXING 2QDQRXWGRRUVKHOWHULQVWDOODWLRQWKHH[KDXVWGLVFKDUJHVLQWRDYHQWSLSH2ULHQWWKHKHDWHUVRWKDWWKHYHQWSLSHGRHV QRWLQWHUIHUHZLWKDGMXVWPHQWRIWKHRSHUDWLQJFRQWUROV7KHFRQWUROSDQHOORFDWHGRQWKHWRSSDQHOFDQEHURWDWHGWRDQ\ RIWKHWKUHHVLGHVRIWKHKHDWHUIRUHDV\DFFHVVVHH)LJXUH 5HPRYHWKHEROWVIURPWKHGRRUSDQHOV5HPRYHERWKGRRUDFFHVVSDQHOV 5HPRYHWKHIRXUFRUQHUZLQJQXWVWKDWVHFXUHWKHWRSSDQHO/LIWWKHWRSSDQHOXSZDUGWRUHPRYHWKHWRSSDQHO 5RWDWHWKHWRSSDQHOWRWKHGHVLUHGSRVLWLRQORFDWHGDWDQJOHV1RWHWKDWWKHFRQWUROSDQHOPXVW127EHORFDWHG RQWKHVLGHZKHUHWKHYHQWLVORFDWHG 5HSODFHWKHWRSSDQHOGRZQRQWRWKHVLGHSDQHOV%HVXUHWKDWWKHUHDUHQRZLUHVFDXJKWXQGHUWKHSDQHO 6HFXUHWKHWRSSDQHOXVLQJWKHIRXUFRUQHUZLQJQXWV 5HDWWDFKWKHGRRUDFFHVVSDQHOV Top Panel Door Acess Panel Door Acess Panel Figure 20. FINAL INSTALLATION CHECK &KHFNWKDWKRUL]RQWDOYHQWSLSHUXQVVORSHXQLIRUPO\DWOHDVW´SHUIRRWFPSHU PHWHUWRFRQGHQVDWHGUDLQV1RVDJVQRGLSVQRKLJKRUORZVSRWV &KHFNWKDWYHQWLVVXSSRUWHGDWHOERZVWHHVDQGKRUL]RQWDODQGYHUWLFDOUXQVDFFRUGLQJ WRPDQXIDFWXUHU¶VLQVWUXFWLRQVDQGFRGHUHTXLUHPHQWV &KHFNWKDWYHQWVXSSRUWVDQGZDOODQGFHLOLQJSHQHWUDWLRQVDOORZIUHHPRYHPHQWVXS GRZQDQGVLGHZD\VZLWKRXWSXWWLQJDQ\VWUDLQVRQWKHKHDWHURUYHQWERG\ &KHFNIRUDWOHDVWVL[LQFKFPIUHHDLUFOHDUDQFHEHWZHHQWKHKHDWHUYHQWSLSHDQG FRPEXVWLEOHPDWHULDOV &KHFNWKDWDOOMRLQWVDUHFRPSOHWHO\WRJHWKHUDQGVHDOHG For Heater mounting bolts and clamps, purchase separately Bolt Down Bracket Kit, Part No. 460738. Lead Anchor ,Q)ORULGDEXLOGLQJFRGHVUHTXLUHWKDWWKHKHDWHUEHDQFKRUHGWRWKHHTXLSPHQWSDG RUSODWIRUPWRZLWKVWDQGKLJKZLQGSUHVVXUHVFUHDWHGGXULQJKXUULFDQHV$%ROW'RZQ %UDFNHW.LW31LVDYDLODEOHZLWKDQFKRUFODPSVGHVLJQHGWRKROGWKHXQLW WRWKHHTXLSPHQWSDGLQKLJKZLQGFRQGLWLRQV,QVWDOODWLRQRIWKHDQFKRUFODPSVDUH UHFRPPHQGHGLQDOOLQVWDOODWLRQVDQGDUHUHTXLUHGLQ)ORULGD6HH)ORULGD%XLOGLQJ &RGH Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 28 Section 3. Installation Instructions ELECTRICAL CONNECTIONS (OHFWULFDO5DWLQJ+]9ROWV$&VLQJOHSKDVH (QFORVHWKHLQFRPLQJ$&SRZHUOLQHWRWKHKHDWHULQDQDSSURYHGÀH[LEOHFRQGXLWFRQQHFWHGGLUHFWO\WRWKHMXQFWLRQER[ RQWKHLQVLGHRIWKHDFFHVVGRRUSDQHO/LQHYROWDJH¿HOGZLULQJVKRXOGEHJDXJHZLWKDFLUFXLWFDSDFLW\RI$PSV CAUTION This heater is designed to operate at 120 or 240 VAC. It is not recommended to be connected to OR operate on a 208 VAC. NOTE s Before making any electrical connections to the power supply, remove the access door panels, open the control box and plug in the correct plug (120 volt or 240 volt). CAUTION The heater ships from the Factory with the 240V plug installed. Installing the 120V plug and then connecting the heater to 240V line current will immediately destroy the transformer, control board and ignition control module, and will void warranty. If you install the 240V plug and connect the heater to 120 volts line current, the heater will not operate. s )FANYOFTHEORIGINALWIRINGSUPPLIEDWITHTHISHEATERMUSTBEREPLACEDINSTALLERMUSTSUPPLY.O!7'6½#5, approved AWM low energy stranded) copper wire or it’s equivalent. 3OHDVHUHDGWKHER[HVKHDGHG³,03257$175($'0(),567´RQSDJHVDQG45EHIRUHSURFHHGLQJ $OOZLULQJPXVWEHLQDFFRUGDQFHZLWKDOODSSOLFDEOHFRGHV 7KHKHDWHUZKHQLQVWDOOHGPXVWEHHOHFWULFDOO\JURXQGHGDQGERQGHGLQDFFRUGDQFHZLWKORFDOFRGHVRULQWKHDEVHQFH RIORFDOFRGHVZLWKWKH1DWLRQDO(OHFWULFDO&RGHRUWKH&DQDGLDQ(OHFWULFDO&RGHDVDSSOLFDEOH$ERQGLQJOXJLV SURYLGHGRQWKHRXWVLGHRIWKHSDQHOXQGHUWKHYHQWIRUWKLVSXUSRVH (OHFWULFDOSRZHUFLUFXLWVWRWKHSRROKHDWHUPXVWIROORZORFDOFRGHVDQG1DWLRQDO(OHFWULFDO&RGHRU&DQDGLDQ(OHFWULFDO &RGHDVDSSOLFDEOH $OOZLULQJEHWZHHQWKHKHDWHUDQGGHYLFHVQRWDWWDFKHGWRLWRUEHWZHHQVHSDUDWHGHYLFHVZKLFKDUHLQVWDOOHGLQWKH ¿HOGPXVWEH³7\SH7´ZLUHUDWHGIRU&ULVH $OOOLQHYROWDJHZLULQJVKDOOEHHQFORVHGLQDSSURYHGÀH[LEOHFRQGXLWDQGVKDOOEHVHFXUHO\DWWDFKHGWRWKH¿HOG ZLULQJER[ORFDWHGLQVLGHWKHDFFHVVGRRUSDQHO7KHFRQGXLWRUFDEOHFRQQHFWRUDWWKH¿HOGZLULQJER[VKRXOGFRQWDLQ DQLQVXODWLQJEXVKLQJRULWVHTXLYDOHQWWRSUHYHQWDEUDVLRQRIWKHZLUHVDVWKH\HQWHUWKHER[ 7KH¿OWHUSXPSVKRXOGUXQFRQWLQXRXVO\ZKHQWKHKHDWHULVRQDQGIRUDWOHDVWPLQXWHVDIWHUWKHKHDWHUWXUQV RII$Q\VZLWFKHVLQWKHSXPSFLUFXLWLQFOXGLQJFLUFXLWEUHDNHUVWKDW FDQGLVFRQQHFWWKHSXPSPXVWDOVRGLVFRQQHFWWKHKHDWHU 'RQRWZLUHVLQJOHSROHVZLWFKHVLQFOXGLQJSURWHFWLYHGHYLFHVLQWRD JURXQGHGOLQH7KHKHDWHULVQRWVHQVLWLYHWRSRODULW\ &RQQHFWWKHL1RIWKHSRZHUVXSSO\WRWKHEODFNZLUHWKHL2RUQHXWUDO OHDGWRWKHredZLUHDQGWKHJURXQGZLUHWRWKHgreenZLUH$WLPHFORFN FRQWUROOLQJWKH¿OWHUSXPSVKRXOGKDYHDORZYROWDJH)LUHPDQ¶V6ZLWFKWKDW VZLWFKHVRIIWKHKHDWHUDWOHDVWPLQXWHVEHIRUHVKXWWLQJRIIWKHSXPS $OZD\VXVHFULPSW\SHFRQQHFWRUVZKHQFRQQHFWLQJWZRZLUHV AC Plug 120 Volt or 240 Volt Figure 21 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions 29 CONNECTION OF FIREMAN’S SWITCH OR REMOTE CONTACT CAUTION If, while there is line voltage connected to the heater, you touch either line voltage terminal with any 24VAC wire that is connected to the control board (including the Fireman’s Switch jumper), you will immediately destroy the control board and void the warranty. Figure 22 REMOTE CONTROL CONNECTIONS 6ZLWFKRIISRZHUWRKHDWHUDWPDLQFLUFXLWEUHDNHUSDQHO 8QEROWDQGUHPRYHWKHDFFHVVGRRUSDQHOV 2SHQFRQWUROER[FRYHUVHH)LJXUH D To connect a 2-Wire Control VXFK DV ,QWHOOL7RXFK® RU (DV\7RXFK &RQWURO 6\VWHP or a timer: Y Y THERMISTOR Y Y 24 VAC J6 1 FS 24VAC BK O OPERATING CONTROL O MEMBRANE PAD CONNECTION ENABLE TOGGLE DISABLE TOGGLE W TRANS FUSE FUSE BK 9 &RQQHFWZLUHVEHWZHHQWKHFRQWUROERDUGWHUPLQDOV RQWKHKHDWHUDQGWKHH[WHUQDOUHOD\VDVVKRZQLQ )LJXUH8VHDWOHDVWUHOD\VSHUKHDWHUWRDOORZ IRUDQ³2))VHWWLQJ´RQHDFKKHDWHUPRGH6HOHFW UHOD\VWKDWFDQKDQGOHORJLFOHYHOVZLWFKLQJ'2127 DSSO\OLQHYROWDJHWRFRQWUROERDUGWHUPLQDOV 0RYH MXPSHU DV VKRZQ RQ )LJXUH WR HQDEOH H[WHUQDOFRQWURODQGWRGLVDEOHWKHKHDWHUPHPEUDQH SDG¶V³3RRO21´DQG³6SD21´EXWWRQVWKH³2))´ NH\RQWKHPHPEUDQHSDGUHPDLQVIXQFWLRQDO .QRFNRXWVDUHSURYLGHGWRURXWHWKHZLUHVWKURXJK WKHERWWRPDQGWKHWRSRIWKHFRQWUROER[DQGSDVW WKHMXQFWLRQER[ &ORVHFRQWUROER[FRYHU VAL TH IND GND 24VAC 5HPRYHWKHIDFWRU\LQVWDOOHGMXPSHUIURPWKH)LUHPDQ¶V6ZLWFKWHUPLQDOV &RQQHFWZLUHVEHWZHHQWKH)LUHPDQ¶V6ZLWFKWHUPLQDOVRQWKHKHDWHUDQGWKH UHOD\&RQQHFWZLUHVIURPWKHFRQWUROOHURUWLPHUWRWKH)LUHPDQ¶V6ZLWFK &RQWUROOHU WLPHU RU UHOD\ VKRXOG EH VL]HG WR KDQGOH 9$& DW $PS EHFDXVHLWZLOOEHFRPSOHWLQJWKH9$&FRQWUROERDUGFLUFXLWRQWKHKHDWHU DVVKRZQLQ)LJXUH'2127DSSO\OLQHYROWDJHWRWKH)LUHPDQ¶V6ZLWFK WHUPLQDOV8VHJDXJHZLUHZLWKDPLQLPXP´PPWKLFNLQVXODWLRQ UDWHGIRUDWHPSHUDWXUHULVHRIDWOHDVW& .QRFNRXWVDUHSURYLGHGWRURXWHWKHZLUHVWKURXJK WKHERWWRPRIWKHFRQWUROER[DQGSDVWWKHMXQFWLRQ TRANS ER[ E To connect a 3-Wire Control: TERMINAL BOARD F I R E M A N S L1 F1 TRAN S FL S W I T C H W W L2 R BM R L2 L1 Figure 23. Rev. B 8/14 GND JUNCTION BOX G R L2 L1 GROUND (GND ) 127,&(7KHIXVHIRUWKH)LUHPDQ¶V6ZLWFKLVD$PS ó[ó´IDVWEORZIXVHZKLFKLVFRPPRQO\DYDLODEOH 12 Pin Receptacle 7R FRQWURO KHDWHUV WKDW DUH RSHUDWHG LQ SDUDOOHO FRQQHFW ZLULQJ DW VDPH ORFDWLRQV RQ KHDWHU DV :LUH RU :LUH &RQWURO,WLVLPSHUDWLYHWKDWHDFKFRQWUROFLUFXLWLVLVRODWHG IURP WKH RWKHU FRQWURO FLUFXLWV WR DYRLG WKDW FXUUHQW ZLOO ÀRZIURPRQHKHDWHUWRDQRWKHUWKURXJKWKHFRQWUROFLUFXLWV BK 5HLQVWDOOWKHDFFHVVGRRUSDQHOV 24VAC Time Clock or Remote (Purchase Separately – Supplies Power to Circulator Pump) Fireman's Switch Completes the heater 24 Volt AC Control Board Circuit. DO NOT connect this circuit to Line Voltage! MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 30 Section 3. Installation Instructions HEATER WIRING DIAGRAM (3-WIRE SYSTEM) CONNECTION DIAGRAM AGS Switch Air Flow Switch Stack Flue Sensor Extra Switch 1 Gas Valve Hi-Limit Switch Y/R Y/BL Y/O Pressure Switch Y/W Y Y Y Y Y O O BL W O O W THERMISTOR HLS FS PS 24VAC R Y BR BR PR PR R VAL TH IND GND 24VAC Y/W ES1 OPERATING CONTROL AFS NA/LP Models Only Y/W J6 Y 1 BL Y/O Y/BL Y/R Y Y Y Y MEMBRANE PAD CONNECTION AGS SFS 6 JMP3 GAS 1 External Control Interface Circuit Disabled, Heater Membrane Pad Enabled Spa Line Common Line Pool Line JMP External Control Interface W Y BK 1 JMP F1 24 F2 VAC DIAGNOSTIC INDICATOR 1 IGNITION CONTROL MODULE Y External Control Interface Circuit Enabled, "Pool On" and "Spa On" Keys Disabled. "OFF" Key on Membrane Pad Remains Functional. Y 24 VAC S1 240 GY S1/ 120 L1 L2 GY BK S2 SEC TH IND VAL GND Y/W GY Y/O W Y/BL Y/R O BK 120 VAC IGNITER Y/W W GND BK Plug –12 pin 120V – Black 240V – Red O GY BK L1 BK F1 F I R E M A N S TRAN S FL S W I T C H L2 BM BK 1 R Y GY R W W R GY BK W R W Y R BK Y BLOWER BL JUNCTION BOX Line 1 BK Line 2 R Ground G NOTICE: Touching any 24VAC wire, including the Fireman's Switch wire, to any 120/240V terminal while the heater is connected to line power will immediately destroy the control board and void the warranty. BL G GND Replace jumper with leads to Fireman"s Switch (field installed) 12 Position Receptacle Figure 24. GND MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 3. Installation Instructions 31 HEATER ELECTRICAL SCHEMATIC LADDER DIAGRAM LADDER DIAGRAM 120/240 VAC L1 L2 IGNITER L1 S1 F1 F2 S2 L2 BLOWER GND 120/240 VAC CLASS II TRANSFORMER 24 VAC OPERATING CONTROL 24 VAC 24 VAC GND AIR FLOW SWITCH LOGIC 24V TH WATER PRESSURE SWITCH HI LIMIT SWITCH IND COM NO AGS SWITCH VAL GAS VALVE STACK FLUE SENSOR THERMISTOR SENSOR NOTES: 1.) L1 S2 L2 F1 GND F2 IND S1 24 VAC VAL AND TH ARE CONNECTED ON THE IGNITION MODULE. Rev. B 8/14 2. ) PIN AND SOCKET CONNECTOR. 3. ) IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, THEY MUST BE REPLACED WITH TYPE 105˚ C OR ITS EQUIVALENT. Figure 25. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 32 Section 4. Operation Instructions Operation Instructions BASIC SYSTEM OPERATION 6WDUWSXPSPDNHVXUHWKHSXPSLVUXQQLQJDQGLVSULPHGWRFORVHWKHZDWHUSUHVVXUHVZLWFKDQGVXSSO\SRZHU WRKHDWHU%HVXUHWKHSRRODQGRUVSDLVSURSHUO\¿OOHGZLWKZDWHU)ROORZWKH/LJKWLQJ2SHUDWLQJLQVWUXFWLRQVEHORZ (%!4%2(3)%,%#42/.)#)'.)4)/.,)'(4).'/0%2!4)/. FOR YOUR SAFETY: READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not attempt to light the heater if you suspect a gas leak. Lighting the heater can result in a fire or explosion which can cause personal injury, death, and property damage. START-UP AND OPERATION START-UP AND SHUTDOWN INSTRUCTIONS ARE ON THE LABEL ATTACHED TO THE COVER OF THE APPLIANCE CONTROL BOX. BEFORE START-UP $7KLV DSSOLDQFH GRHV QRW KDYH D SLORW ,W LV HTXLSSHG ZLWKDQLJQLWLRQGHYLFHZKLFKDXWRPDWLFDOO\OLJKWVWKH EXUQHUV'RQRWWU\WROLJKWWKHEXUQHUVE\KDQG ) %HIRUH RSHUDWLQJ WKH DSSOLDQFH IRU WKH ¿UVW WLPH RU DIWHULWKDVEHHQRIIIRUDQH[WHQGHGWLPHSHUIRUPWKH IROORZLQJFKHFNOLVW %%()25(23(5$7,1*VPHOODOODURXQGWKHDSSOLDQFH DUHDIRUJDV%HVXUHWRVPHOOQH[WWRWKHÀRRUEHFDXVH VRPHJDVLVKHDYLHUWKDQDLUDQGZLOOVHWWOHRQWKHÀRRU WHAT TO DO IF YOU SMELL GAS ± 'RQRWWU\WROLJKWDQ\DSSOLDQFH ± 'RQRWWRXFKDQ\HOHFWULFDOVZLWFKGRQRWXVHDQ\SKRQH LQ\RXUEXLOGLQJ ± ,PPHGLDWHO\FDOO\RXUJDVVXSSOLHUIURPDQHLJKERU¶V SKRQH)ROORZWKHJDVVXSSOLHU¶VLQVWUXFWLRQV ± ,I \RX FDQQRW UHDFK \RXU JDV VXSSOLHU FDOO WKH )LUH 'HSDUWPHQW &8VHRQO\\RXUKDQGWRWXUQWKHJDVFRQWURORQRURII 1HYHU XVH WRROV ,I \RX FDQQRW FKDQJH WKH 212)) VHWWLQJE\KDQGGRQ¶WWU\WRUHSDLULWFDOODTXDOL¿HG VHUYLFHWHFKQLFLDQ)RUFHGRUDWWHPSWHGUHSDLUPD\UHVXOW LQD¿UHRUH[SORVLRQ 5HPRYHGHEULVRURWKHUDUWLFOHVIURPLQVLGHWKHKHDWHU DQGWKHDUHDDURXQGWKHKHDWHUDQGLWVH[KDXVWYHQW 0DNHVXUHWKHYHQWLODWLRQRSHQLQJVDUHFOHDURIGHEULV RUREVWUXFWLRQ)RULQVWDOODWLRQVLQDQHQFORVHGVSDFH PDNHVXUHRSHQLQJVIRUFRPEXVWLRQDQGYHQWLODWLRQ DLUDUHXQREVWUXFWHG .HHSKHDWHUDUHDFOHDUDQGIUHHIURPFRPEXVWLEOHV ÀDPPDEOHOLTXLGVDQGFKHPLFDOV &KHFNWKDWDOOZDWHUFRQQHFWLRQVDUHWLJKW :DWHU PXVW EH ÀRZLQJ WKURXJK WKH KHDWHU GXULQJ RSHUDWLRQ0DNHVXUHWKDWSRROVSDLV¿OOHGZLWKZDWHU DQGKDYHSXPSRSHUDWLQJ&KHFNWKDWZDWHUÀRZLV XQREVWUXFWHG IURP WKH DSSOLDQFH :KHQ RSHUDWLQJ IRUWKH¿UVWWLPHRUDIWHUDQH[WHQGHGVKXWGRZQUXQ ¿OWHUSXPSIRUVHYHUDOPLQXWHVWRFOHDUDOODLUIURP WKHV\VWHP ''RQRWXVHWKLVKHDWHULIDQ\SDUWKDVEHHQXQGHUZDWHU ,PPHGLDWHO\FDOODTXDOL¿HGVHUYLFHWHFKQLFLDQWRLQVSHFW WKHKHDWHUDQGWRUHSODFHDQ\SDUWRIWKHFRQWUROV\VWHP DQGDQ\JDVFRQWUROZKLFKKDVEHHQXQGHUZDWHU ( 'RQRWRSHUDWHWKHSRROKHDWHUXQOHVVWKHSRRORUVSDLV SURSHUO\¿OOHGZLWKZDWHU MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 4. Operation Instructions 33 OPERATING INSTRUCTIONS 67235HDGWKHVDIHW\LQIRUPDWLRQRQSDJH Water 6HWERWKSRRODQGVSDWKHUPRVWDWVWRWKHORZHVWVHWWLQJV Pressure Switch 7XUQRIIDOOHOHFWULFSRZHUWRWKHDSSOLDQFH7XUQ2))WKH0DQXDO 6KXW2II9DOYHDVVKRZQEHORZ 7KLVDSSOLDQFHGRHVQRWKDYHDSLORW,WLVHTXLSSHGZLWKDQLJQLWLRQ GHYLFHZKLFKDXWRPDWLFDOO\OLJKWVWKHEXUQHU'RQRWWU\WROLJKWWKH EXUQHUE\KDQG 5HPRYHWKHDFFHVVGRRUSDQHOVE\XQIDVWHQLQJWKHWZRVFUHZV ORFDWHGRQHDFKGRRUWKHQOLIWXSDQGRXWIURPWKHERWWRPRIWKHSDQHO WRUHPRYH,IQHFHVVDU\WKHVFUHZVPD\EHXVHGDVKDQGOHV VHH)LJXUH 7RJJOH6W\OH9DOYH3XOOWRJJOHWRZDUG\RXWRWXUQJDVRII VHH)LJXUH Figure 26. :DLW¿YHPLQXWHVWRFOHDURXWDQ\JDV,I\RXWKHQVPHOOJDV 6723)ROORZ³%´LQWKH³%HIRUH6WDUWXS´LQVWUXFWLRQVSDJH ,I\RXGRQ¶WVPHOOJDVJRWRWKHQH[WVWHS 7XUQ21WKH0DQXDO6KXW2II9DOYHDVVKRZQEHORZ7RJJOH6W\OH 9DOYH3XVKWKHWRJJOHVZLWFKDZD\IURP\RXWRVZLWFKWKHJDVRQ 5HSODFHWKH'RRU$FFHVV3DQHOV$OOSDQHOVPXVWEHLQSODFHZKHQ RSHUDWLQJWKHKHDWHU 6HWZD\YDOYHVRQLQOHWDQGRXWOHWWRSRRORUVSDDVDSSURSULDWH 7XUQRQDOOHOHFWULFSRZHUWRWKHDSSOLDQFH 3UHVVHLWKHUWKH322/21RU63$21EXWWRQVZLWFKRQWKHRSHUDWLQJ FRQWURO 6HWWKHWKHUPRVWDWWRGHVLUHGVHWWLQJNOTICE:6HWSRLQWPXVWEHDERYH DFWXDOZDWHUWHPSHUDWXUHRUEXUQHUZLOOQRW¿UH6HH³23(5$7,1*WKH &21752/3$1(/´ 7KHEORZHUVKRXOGFRPHRQLPPHGLDWHO\DQGDIWHUDERXWVHFRQGVWKH EXUQHUVKRXOG¿UH:KHQRSHUDWLQJIRUWKH¿UVWWLPHWKHEXUQHUPD\QRW Figure 27. ¿UHRQWKH¿UVWWU\EHFDXVHRIDLULQWKHJDVOLQH,ILWGRHVQRW¿UHDW¿UVW Gas control is shown OFF. Push toggle switch away SXVKWKH2))VZLWFKZDLW¿YHPLQXWHVDQGDJDLQSXVKWKH322/RU from you to switch ON. 63$21VZLWFK7KHEXUQHUVKRXOG¿UHDIWHUDERXWVHFRQGV<RX PD\KDYHWRUHSHDWWKLVXQWLODOORIWKHDLUKDVFOHDUHGWKHJDVOLQH 7KHEXUQHUVKRXOG¿UHXQWLOWKHSRROVSDWHPSHUDWXUHUHDFKHVWKHGHVLUHG WHPSHUDWXUHVHWRQWKHWKHUPRVWDW7KHEORZHUZLOOFRQWLQXHWRUXQIRUDERXWVHFRQGVDIWHUWKHEXUQHUVKXWV RII,IDQ\RIWKHVDIHW\LQWHUORFNVVKRXOGRSHQGXULQJEXUQHURSHUDWLRQWKHEXUQHUVKXWVRIILPPHGLDWHO\EXWWKH EORZHUFRQWLQXHVWRUXQIRUDERXWVHFRQGV6KRXOGRYHUKHDWLQJRFFXURUWKHJDVVXSSO\IDLOWRVKXWRIIWXUQRII WKHPDQXDOJDVFRQWUROYDOYHWRWKHDSSOLDQFH ,IWKHDSSOLDQFHZLOOQRWRSHUDWHIROORZWKHLQVWUXFWLRQVEHORZ Manual ³7278512))*$6727+($33/,$1&(´DQGFDOO\RXUVHUYLFH Shut-off WHFKQLFLDQRUJDVVXSSOLHU Valve TO TURN OFF GAS TO APPLIANCE 3UHVVWKH2))EXWWRQRQRSHUDWLQJFRQWURO 6ZLWFKRIIDOOHOHFWULFSRZHUWRWKHXQLW 7XUQ2))WKH0DQXDO6KXW2II9DOYHDVVKRZQRQULJKW 5HPRYHWKHDFFHVVGRRUSDQHOVVHH)LJXUH 7RJJOH6W\OH9DOYH3XOOWRJJOHWRZDUG\RXWRWXUQJDVRIIVHH)LJXUH 5HSODFHWKH$FFHVV'RRU3DQHOV Rev. B 8/14 MANUAL SHUT-OFF VALVE LOCATION MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Figure 29. 34 Section 4. Operation Instructions SAFETY CONTROLS Figure 28. AIR FLOW SWITCH (AFS) 7KHDLUÀRZVZLWFKVHH)LJXUHLVDVDIHW\GHYLFHXVHGWRLQVXUHWKDWWKHFRPEXVWLRQ DLUEORZHUIDQLVRSHUDWLQJDQGKDVEHHQGHVLJQHGWRPRQLWRUWKHYDFXXPQHJDWLYH SUHVVXUHZLWKLQWKHEORZHUKRXVLQJ7KHDLUÀRZVZLWFKLVIDFWRU\VHWDQGLVFRQQHFWHG XSVWUHDPRIWKHLJQLWLRQPRGXOH7KHLJQLWLRQPRGXOHGRHVQRWRSHUDWHXQOHVVWKHDLU SUHVVXUHVZLWFKDQGDOOVDIHW\VZLWFKHVDUHFORVHG WATER PRESSURE SWITCH Air Flow Switch WARNING Hazardous pressure. Do not bypass the Water Pressure Switch or render it inoperable. Figure 29. 7KHZDWHUSUHVVXUHVZLWFKVHH)LJXUH,IWKHZDWHUÀRZLVUHVWULFWHGWKH ZDWHUSUHVVXUHVZLWFKPD\SUHYHQWWKHEXUQHUIURP¿ULQJDQGFDXVHWKH³6HUYLFH 6\VWHP´OLJKWWRJRRQ,IWKHOLJKWUHPDLQVRQDIWHUWKH¿OWHUKDVEHHQVHUYLFHG KDYHDTXDOL¿HGVHUYLFHWHFKQLFLDQFKHFNWKHV\VWHP Water Pressure Switch )RUGHFNOHYHOKHDWHULQVWDOODWLRQVWKH:DWHU3UHVVXUH6ZLWFKLVIDFWRU\VHWDW SVLN3DNOTE: See, Below Pool Level Installation instructions on page 13,IWKHSUHVVXUHVZLWFKLVRQHIHHW0EHORZRUDERYHWKHSRROZDWHU OHYHOUHVHWWKHVZLWFKVRWKDWLWLVRSHQZKHQWKHSXPSLVRIIDQGFORVHGZKHQ WKHSXPSLVUXQQLQJ7XUQWKHVWDUZKHHORQWKHVZLWFKFORFNZLVHWR UDLVHVHWWLQJKHDWHUEHORZWKHSRRODQGFRXQWHUFORFNZLVHWRORZHUWKH VHWWLQJKHDWHUDERYHWKHSRRO±VHH)LJXUH7HVWWKHVZLWFKDIWHUUHVHWWLQJ NOTICE::KHQWKHKHDWHULVPRXQWHGPRUHWKDQ¿YHIHHW0DERYH RUIRXUIHHW0EHORZWKHGHFNOHYHOD3UHVVXUH Turn star wheel clockwise to raise 6ZLWFKLVQRORQJHUDGHTXDWH$)ORZ6ZLWFKPXVWEH pressure set point if pressure switch is LQVWDOOHGLQVWHDG more than 4 feet (1.2M) below water level NOTICE:+HDWHURSHUDWLRQZLWKLQFRUUHFW3UHVVXUH 6ZLWFKVHWWLQJPD\FDXVHRSHUDWLRQZLWKQRZDWHUÀRZ 2SHUDWLRQRIWKHKHDWHUZLWKRXWVXI¿FLHQWZDWHUÀRZ PD\VHYHUHO\GDPDJHLW Star Wheel HIGH LIMITS $ ³+LJK /LPLW´ LV D VDIHW\ GHYLFH WKDW RSHQV WKH HOHFWULFDOFLUFXLWDQGVKXWVRIIWKHKHDWHUEDVHGRQDZDWHU WHPSHUDWXUH VHW SRLQW ZLWKLQ WKH ³+LJK /LPLW 'HYLFH´ 7KH0DVWHU7HPS®KHDWHUFRQWDLQVWZRKLJKOLPLW GHYLFHVZKLFKDUHORFDWHGRQWKHPDLQLQOHWRXWOHWKHDGHU A reference scale is on the back of pressure switch Turn star wheel counterclockwise to lower pressure set point if pressure switch is more than 5 feet (1.5M) above water level MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Figure 30. Rev. B 8/14 Section 4. Operation Instructions 35 SAFETY CONTROLS (continued) Flame Current Check Point OPERATION OF IGNITION MODULE Diagnostic LED 1 Flash - Air Flow Fault 2 Flashes - Flame No Call for Heat 3 Flashes - Ignition Lockout 7KH,JQLWLRQ0RGXOHVHH)LJXUHLVPLFURSURFHVVRUEDVHGDQG RSHUDWHVRQ9$&VXSSOLHGE\WKHWUDQVIRUPHU7KHFRQWUROXWLOL]HV DPLFURSURFHVVRUWRFRQWLQXDOO\DQGVDIHO\PRQLWRUDQDO\]HDQG FRQWUROWKHSURSHURSHUDWLRQRIWKHJDVÀDPHKROGHU7KHPRGXOH ZLWKWKHSUHVHQFHRIWKHÀDPHVHQVRUXVLQJÀDPHUHFWL¿FDWLRQ DOORZVWKHKHDWHUWRRSHUDWH OPERATING THE CONTROL PANEL Figure 31. 7KH¿YHRSHUDWLQJVZLWFKHVDUHVHH)LJXUH Temperature Up and Down POOL ON 3UHVVWKLVEXWWRQWRJRYHUQKHDWHURSHUDWLRQE\WKH SRROWHPSHUDWXUHVHWWLQJ SPA ON 3UHVVWKLVEXWWRQWRJRYHUQKHDWHURSHUDWLRQE\WKH VSDWHPSHUDWXUHVHWWLQJ Digital Temperature Display HEATER OFF 3UHVVWKLVEXWWRQWRVZLWFKRIIWKHKHDWHU ▲ TEMP 3UHVVWKLVEXWWRQWRUDLVHWKHWHPSHUDWXUHVHWWLQJ ▼ TEMP 3UHVVWKLVEXWWRQWRORZHUWKHWHPSHUDWXUHVHWWLQJ 7RWRJJOHWKHGLVSOD\EHWZHHQGHJUHHV&HQWLJUDGH&DQGGHJUHHV )DKUHQKHLW) System Operation Indicator Lights Dual Temperature Controls 7XUQWKH2SHUDWLQJ&RQWURO2)) Heater "OFF" Switch Figure 32. 3UHVV▲TEMPRU▼TEMPIRUVHFRQGV7KHGLVSOD\ZLOOÀDVKRQFHDQGFKDQJHPRGHV&WR)RUYLFHYHUVD 7XUQWKH2SHUDWLQJ&RQWURO21 :KHQHLWKHUWKH▲TEMPRU▼TEMPEXWWRQVDUHGHSUHVVHGWKHGLJLWDOGLVSOD\ZLOOLQGLFDWHWKHWHPSHUDWXUHVHWWLQJ $IWHU¿YHVHFRQGVWKHGLVSOD\ZLOOUHWXUQWRWKHDFWXDOSRROVSDWHPSHUDWXUH ,QDGGLWLRQWRWKHGLJLWDOWHPSHUDWXUHGLVSOD\WKHUHDUH¿YHLQGLFDWRUOLJKWV 7KHPOOL ONOLJKWLQGLFDWHVWKDWWKHSRROZDWHUWHPSHUDWXUHLVJRYHUQLQJRSHUDWLRQRIWKHKHDWHU 7KHSPA ONOLJKWLQGLFDWHVWKDWWKHVSDZDWHUWHPSHUDWXUHLVJRYHUQLQJRSHUDWLRQRIWKHKHDWHU 7KHHEATINGOLJKWFRPHVRQDQGVWD\VRQZKHQWKHEXUQHULV¿ULQJ7KLVOLJKWVKRXOGEHRQZKHQHYHUWKHEXUQHULV RQ,WEOLQNVZKHQWKHKHDWHULVFDOOLQJIRUKHDWEXWQRW¿ULQJ,IWKLVOLJKWLVRQEXWWKHEXUQHUIDLOVWRFRPHRQRQHRIWKH ³VHUYLFH´OLJKWVVKRXOGFRPHRQLQGLFDWLQJDIDXOWLQWKHV\VWHP 7KHSERVICE SYSTEMOLJKWLQGLFDWHVWKDWWKHUHLVLQVXI¿FLHQWZDWHUÀRZWRWKHKHDWHU,IWKHSXPSLVRSHUDWLQJWKLV XVXDOO\LQGLFDWHVWKDWWKH¿OWHUDQGRUVNLPPHUVVKRXOGEHFOHDQHGVRPH¿OWHUVPD\UHTXLUHEDFNZDVKLQJ,IWKHOLJKW UHPDLQVRQDIWHUWKH¿OWHUVNLPPHUVKDYHEHHQVHUYLFHGWKHV\VWHPVKRXOGEHFKHFNHGE\DTXDOL¿HGVHUYLFHWHFKQLFLDQ 7KHSERVICE HEATEROLJKWLQGLFDWHVDIDXOWLQWKHKHDWHURULWVFRQWUROV,IWKLVOLJKWFRPHVRQVKXWGRZQWKHKHDWHU 6HH³7278512))*$6727+($33/,$1&(´RQSDJHDQGKDYHDTXDOL¿HGVHUYLFHWHFKQLFLDQFKHFNWKHV\VWHP WARNING Risk of explosion or fire causing burns or death if safety interlocks are disabled. DO NOT attempt to operate heater when SERVICE HEATER light is on or if blower or burner will not start. Instead, follow instructions under “To Switch Off Gas to the Appliance,” and call a qualified service technician to repair unit. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 36 Section 4. Operation Instructions TEMPERATURE SETTING 7KHKHDWHUFRPHVIDFWRU\VHWDW)IRUWKHSRROPRGHDQG)IRUWKHVSDPRGH8VLQJWKHXSDQGGRZQDUURZV \RXFDQVHWWKHWKHUPRVWDWVWRDPLQLPXPWHPSHUDWXUHRI)RUDPD[LPXPRI),I\RXGHVLUHWRKHDWRQO\RQH ERG\RIZDWHUWKHWKHUPRVWDWLVFDSDEOHRIDQRIIPRGH$VDQH[DPSOHLI\RXRQO\ZLVKWRKHDWWKHVSDDQGQRWWKHSRRO VLPSO\GHSUHVVDQGKROGWKHSRROGRZQDUURZDQGWKHWKHUPRVWDWZLOOORZHULWVVHWWLQJWR)WKHQJRWRDQRIIPRGH MAXIMUM TEMPERATURE SET POINT 8QEROWDQGUHPRYHWKHGRRUSDQHOVVHH)LJXUH $FFHVVWKHFRQWUROSDQHOERDUGRQWKHXQGHUVLGHRIWKHWRSFRYHU/RFDWHWKH\HOORZEXWWRQRQWKHFRUQHURIWKH FRQWUROERDUG 3XVKWKHMax. Temp. Set PointEXWWRQRQWKHEDFNRIWKHFRQWUROERDUGVHH)LJXUH 7KHIROORZLQJVHTXHQFHVKRXOGKDSSHQ $ 7KHXQLWZLOOFRPHRQDQGWKHPOOL ONOLJKWZLOOFRPHRQ % 3UHVVWKH▲TEMPRU▼TEMPSDGRQ723RIWKHSDQHOWRVHWPD[LPXPSRROWHPSHUDWXUH & :DLWXSWRVHFRQGVWKHPOOL ONOLJKWZLOOJRRIIDQGWKH SPA ONOLJKWZLOOFRPHRQ7RRYHUULGHWKH WLPHGHOD\SXVKWKH Max. Temp. Set PointEXWWRQDJDLQ ' 3UHVVWKH▲TEMPRU▼TEMPEXWWRQRQWKHFRQWUROSDQHODQGVHWPD[LPXPVSDWHPSHUDWXUHWR) &RUOHVV ( :DLWXSWRVHFRQGVWKHSPA ONOLJKWZLOOJRRIIDQGWKHXQLWZLOOVKXWGRZQ7RRYHUULGHWKHWLPHGHOD\ SUHVVWKHMax. Temp. Set PointEXWWRQDJDLQ 5HLQVWDOOWKHDFFHVVGRRUSDQHOV Top Panel T E S AX M Door Acess Panel Door Acess Panel S1 T E S AX M S1 Figure 33. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Figure 34. Rev. B 8/14 Section 5. Troubleshooting 37 Troubleshooting Instruction Initial Troubleshooting Only qualified, trained service technicians with appropriate test equipment should service the heater. Remember that all parts of the system affect heater operation. Before starting this troubleshooting procedure, make sure that the pump is running correctly, that there are no blockages in the system, that the valves are correctly set and that the time clock is correctly set and is running. IMPORTANT! READ ME FIRST! NOTICE: Installing the black 120 volt plug in the control box and then connecting the heater to a 240 volt line will destroy the trans former, control broad, and ignition control module, and will void the warranty. If you install the red 240 volt plug and then connect the heater to a 120 volt line, the heater will not operate. READ THE FOLLOWING CAREFULLY: 1. Check the line voltage to your heater. This heater will operate on either 120 Volts AC or 240 Volts AC. 2. Remove the covers and check the 12-pin plug in the back of the control box. The plug must match the voltage in the heater circuit. 3. If the 12-pin plug is not plugged into the back of the control box, select the correct plug from the bag in the control box and plug it in. The BLACK plug is for 120 volts, the RED plug is for 240 volts. Start here for directions to specific Troubleshooting Chart Is green “POOL” or “SPA” LED “on”? NO Go to chart “HEATER WILL NOT FIRE - A” (Page 38) YES Go to chart “HEATER WILL NOT FIRE - B” (Page 39) YES Is red “SERVICE SYSTEM” LED “on”? NO Is red “SERVICE HEATER” LED “on”? YES NO Are any red diagnostic LED’s on back of board (AGS, AFS, SFS, HLS, PS or THERMISTOR) “on” NOTICE: Any or all of the diagnostic LED’s may come “on” momentarily when you turn on the power to the heater. Go to specific safety switch troubleshooting chart (Pages 41 and 42) YES Go to chart ‘HEATER WILL NOT FIRE -C” (Page 40) NO Turn off power to heater for about 5 seconds, and turn back on. Make sure temperature setting is above water temperature. Wait one minute. Do any diagnostic LED’s on back of board (AGS, AFS, SFS, HLS, PS, or THERMISTOR) come “on” and stay on? YES YES NO Does red “SERVICE HEATER” LED come “on” NO Verify that water temperature setting is above water temperature reading. If it is, and heater either will not fire or no red LED’s come “on”, replace Control Board. WARNING Hazardous voltage. Can shock, burn or kill. Disconnect power before servicing any components. Rev. B 8/14 WARNING Fire and Explosion hazard. Do not jumper switch terminals to remedy a failed safety switch. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 38 Section 5. Troubleshooting Heater Will Not Fire - A Start NO Is green “SPA” or “POOL” LED “on” YES Check that correct 12-pin plug is installed (red is 240V, black is 120V) YES Depress “POOL” or “SPA” ON button on Membrane Pad. Does “POOL” or “SPA” LED come on? NO YES Check for line voltage to heater. NO Heater should fire on demand for heat. Restore power to heater. YES NO If plug is not installed: Install correct plug. 240V plug in 120V circuit: Replace with correct plug. 120V plug in 240V circuit: Replace transformer, control board, and ignition control module (see “HEATER WILL NOT FIRE-C and -D”, Pages 40 and 41). Check fuse and all other 24V components for damage. Check for 24 VAC at secYES ondary of Transformer. NO Check for Line Voltage between L1 and L2 terminals on Terminal Board. NO YES Check for Line Voltage at Transformer primary pins. White connects to Pin 3 on Transformer, Black to Pin 2, Orange to Pin 1. 240V: check Pin1 to Pin 3. 120V: check Pin 2 to Pin 3. Jumper Fireman’s Switch at Terminal Board and depress “POOL” or “SPA” ON button on membrane pad. Does “SPA” or “POOL” LED come “on”? NO Check wiring connections between power supply and Junction Box and between Junction Box and Terminal Board; restore continuity. Check wiring connections between Terminal Board and Transformer primary and restore continuity. YES Replace Transformer. YES Check Fireman’s Switch circuit connections (time clock, wiring, external controller relay). NO YES NO Leaving jumper in place, check for 24 VAC between Fireman’s Switch terminals and ground. Remove jumper. Check ribbon cable connection between Membrane Pad and J6 on Control Board. Depress “POOL” or “SPA” On pad again. Does “POOL” or “SPA” LED come on? Jumper pins 6 and 5 on J6 of Control Board. Does “SPA” LED come on? Jumper pins 6 and 4 on J6 of Control Board. Does “POOL” LED come on? NO Remove jumper. Check wiring between Transformer and J7 terminals on Control Board and between J7 and Fireman’s Switch on Terminal Board, check fuse, and restore continuity. YES Heater should fire on demand for heat. YES Replace Membrane Pad. NO Replace Control Board. GO TO “HEATER WILL NOT FIRE - B” Page 39 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 5. Troubleshooting 39 Heater Will Not Fire - B Start Is red “SERVICE HEATER” LED “on” NO Is red “SERVICE SYSTEM” LED on? NO YES YES Verify that pump is on, filter is not blocked, and the water flow is above the minimum requirement. NO YES With pump running, adjust Water Pressure Switch to lower pressure until ‘SERVICE SYSTEM” LED goes out. Then verify that “SERVICE SYSTEM” LED goes on with pump off. Increase POOL/SPA temperature setting on Membrane Pad above actual water temperature. Heater should fire on demand for heat. If not, and no other red LED’s light, replace Control Board. Service pump/filter and eliminate other flow obstructions. YES Heater should fire on call for heat. Re-verify that water flow is above minimum requirement. NO Minimum Flow Requirements Check that water pressure is within the adjustment range of the Pressure Switch (0-5 psig) NO Model 175 200 250 300 400 YES CONTINUE Verify that switch wiring is OK and Pressure Switch port is not blocked, and replace water Pressure Switch. Flow 20 gal/min (76 LPM) 20 gal/min (76 LPM) 25 gal/min (95 LPM) 30 gal/min (114 LPM) 40 gal/min (151 LPM) If water pressure is outside of adjustment range that will open switch with pump off and close switch with pump on, replace with flow switch set above minimum flow requirement. Minimum Flow Requirements Model 175 200 250 300 400 Check whether any of the red diagnostic LED’s on back of board (AGS, AFS, SFS, HLS or PS) are “on” YES Flow 20 gal/min (76 LPM) 20 gal/min (76 LPM) 25 gal/min (95 LPM) 30 gal/min (114 LPM) 40 gal/min (151 LPM) Go to “Diagnostic LED’s”, (Pages 42 and 43) NO GO TO “HEATER WILL NOT FIRE - C” Page 40 Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 40 Section 5. Troubleshooting Heater Will Not Fire - C Start NO Is “SERVICE HEATER” LED “on”? YES If any red diagnostic LED’s (AGS, AFS, SFS, HLS, PS, or THERMISTOR) come “on”, go to to Pages 42 and 43. NO Go to “INITIAL TROUBLESHOOTING” Turn off power to heater for 5 seconds, and turn back on. Make sure temperature setting is above water temperature. Wait one minute. YES Does heater fire and stay on? CONTINUE NO NO Did burner fire at all? Did Blower come on? YES YES Verify that gas is flowing to burner during ignition try. Observe gas meter for movement during ignition try (wait for about 30 seconds after calling for heat). Go to “BURNER TROUBLESHOOTING” (Page 44) Go to “HEATER WILL NOT FIRE-D” (Page 41) YES Replace Ignition Control Module. YES NO Check for 24 VAC between VAL and GND terminals on Ignition Control Module. SEE NOTE 2. Check for 24 VAC between VAL and GND terminals on Control Board. SEE NOTE 2. NO Fix wiring between VAL and GND terminals of Ignition Control Module and Control Board. YES Replace Control Board. NO NO Check for 24 VAC between TH and GND terminals on Ignition Control Module. SEE NOTE 1. NO YES Continue to observe heater for several minutes. Cycle heater on and off several times. Observe for delayed or rough ignition, poor combustion, premature extinction of flame, evidence of boiling, or operation of any diagnostic LED. Go to pertinent troubleshooting section if any malfunction is observed. Check for 24 VAC between TH and GND terminals on Control Board. SEE NOTE 1. Verify that gas supply is open all the way to Gas Valve, and Gas Valve is set at “on” position. Check for 24 VAC to Gas Valve terminals during ignition try. (Voltage appears about 24 seconds after call for heat). SEE NOTE 2. YES Replace Gas Valve with identical part. YES NO Fix wiring between TH and GND terminals of Ignition Control Module and Control Board. Replace Control Board. Check for 24 VAC between GAS terminals on Control Board. SEE NOTE 2. YES Fix wiring between GAS terminals on Control Board and Gas Valve. NO Replace Control Board. NOTE 1: Voltage appears immediately after call for heat, and may be on for only about 30 seconds. NOTE 2: Voltage appears about 24 seconds after call for heat, and may be on for only about 7 seconds. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 5. Troubleshooting 41 Heater Will Not Fire - D IMPORTANT! READ ME FIRST! IMPORTANT! READ ME FIRST!! If your heater is correctly connected to 240 Volts AC, the Ignition Control Module (ICM) will convert the 240VAC to an intermittent pulse to the ignitor. Digital meters don’t read this type of signal well. (An analog meter will give a better reading than a digital meter). If the ICM is bad, your volt- meter will read either 0 VAC or 240 VAC. If your ICM is good, your meter will read some voltage between 0 and 240 VAC. Exactly what reading you get will depend on the meter, but with a good ICM, the reading won’t be 0 VAC or 240 VAC, but somewhere in between. Start Gas flows during ignition try, but burner does not fire. NO Go back to chart “HEATER WILL NOT FIRE-C” (Page 40). YES Check voltage across igniter leads; OK? NO Replace Ignition Control Module. On a 120 V installation, check the ignitor for damage if it has seen 240 VAC. Rev. B 8/14 YES Check gas pressure. OK?. YES Replace HSI Igniter. NO Increase gas flow into heater: : Replace gas line with larger line; : Replace regulator; : Replace meter; or : All of the above. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 42 Section 5. Troubleshooting Diagnostic LED's: AGS, AFS, HLS, PS, THERMISTOR Verify that water flow rate is above minimum required for heater. AGS or HLS "on" Replace High Limit Switch (HLS) or Automatic Gas Shutoff (AGS) NO YES YES Verify that inlet water temperature is below 104˚ F. Service pump and filter to restore proper flow. After servicing, verify proper operation of Pressure Switch (PS). NO Replace thermistor or Control Board to correct overheating. CONTINUE If problem persists, verify proper operation of Internal Bypass Valve and Thermal Governor, and check for Heat Exchanger blockage. PS "on" Verify that water flow rate is above minimum required for heater. NO Does Blower operate? YES Service pump and filter to restore proper flow. CONTINUE Verify that wiring is YES OK and pressure tap CONTINUE Adjust Water Pressure Switch to close with pump running and open with is not blocked. Replace Pressure Switch pump off. AFS "on" NO Replace Blower. Verify that wires BM and F1 are correctly connected at the terminal strip (see Heater Connection Diagram, Page 30). YES Disconnect Blower and check for line voltage between pins 1 and 3 of Blower Connector on ignition try. NO YES NO Check for 24 VAC between 24 VAC and GND terminals on Ignition Control Module on ignition try. Check that IND wire is correctly connected. NO Verify correct connection of wiring between 24 VAC and IND terminals on Ignition Control Module and Control Board, and replace Control Board. YES Disconnect wires F1 and F2 from Ignition Control Module and short them together. Does Blower come on? YES THERMISTOR "on" NO NO NO Verify that there is no blockage in Blower intake, Heat Exchanger, and exhaust and that exhaust is not too long (see “Indoor Vent Installation”, Page 23. Verify correct connection of wiring and that pressure taps to AFS are OK. Verify that vinyl tubing to AFS and Blower is not misrouted, kinked, disconnected, or punctured. Replace Air Flow Switch (AFS). If problem persists, replace Blower. Connect correctly and retry. Does Blower start? Replace Blower. Does Blower start on ignition try? Replace Ignition Control Module. Verify Thermistor wiring. If OK, replace Thermistor. CAUTION Do not jumper a safety switch to remedy a failed switch. NOTE: ES1 is a spare and should be jumpered. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 5. Troubleshooting 43 Diagnostic LED's: SFS SFS "on" Check Heat Exchanger Coil for leaks, liming, soot, or low flow. Heater starts and runs OK, but temperature of exhaust climbs to 450˚–500˚ in 3–5 minutes. YES YES Check Thermal Regulator: Open at 120˚? NO Heater starts after several tries, exhaust temperature stays below 250˚. OR Heater doesn’t start at all (exhaust stays cold). Check pressure and volume of fuel supply NO YES DONE Check Thermal-Regulator: Seats correctly? NOT OK DONE Correct Fuel Supply, reset Heater and retry. Heater should fire correctly. NO NO Reset power to Heater and retry. Heater should fire. Replace Stack Flue Sensor DONE NO Reset power to Heater and retry. Heater should fire. Check Heat Exchanger Coil for leaks, liming, soot, or low flow. NO Repeat checks on fuel supply, Thermal Regulator, check for correct orifices, etc. NO Replace Heater Control Board. DONE Reset power to Heater and retry. Heater should fire. YES NO Does the Digital Temperature Display show Error Code “E05” or “E06”? YES Clean/tighten pins as needed. NO NO (Basic) Replace Heater Membrane Pad. DONE Reset power to Heater and retry. Heater should fire. DONE Rev. B 8/14 Replace Heater Membrane Pad. Replace Heater Control Board. Check continuity in wiring harness between Control YES Board and Probe. Continuity OK? Reset power to Heater and retry. Heater should fire. NO (HD ) NO YES Check the J3 and J6 connectors for corrosion/ looseness on the male pins. YES Correct problem; Heater should fire. OK Disconnect the sensor and check continuity across its terminals. Resistance should be 3.5-4.0 megaohms. = open circuit; 0 = shorted. Does sensor check OK? NO NO MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 44 Section 5. Troubleshooting Burner Troubleshooting SYMPTOM CAUSE REMEDY Loud, high-pitched whine Flame is too rich. Verify pressure tap between gas valve and blower inlet. See page 16 and verify that the gas regulator setting is –0.2" (–0.5cm) wc. Contact a qualified technician or service agency to replace the gas orifice. Flame is “fluttery .” Exhaust may have acrid smell or burner may fail to stay lit. Flame is too lean. See page 16 and verify that the gas regulator setting is –0.2" (–0.5cm) wc. Burner pulsates or surges, especially on ignition. Exhaust vent is too long. Reduce length of exhaust vent and/or number of elbows. Combustion appears normal, but flame does not stay lit. Flame current is not being sensed. Check for wet or damaged igniter with low resistance to ground. Replacewith new igniter. Contact a qualified technician or service agency to replace the gas orifice. Verify burner flameholder is properly grounded. Replace Ignition Control Module. Heat Exchanger Troubleshooting SYMPTOM CAUSE REMEDY Boiling in heat exchanger. May be accompanied by “bumping” sounds. Low water flow to heater. Service pump and or filter. Heat exchanger plugged. Service heat exchanger. Correct water chemistry. Bypass valve stuck open. Service bypass valve. Thermal governor stuck closed. Replace thermal governor. Thermal governor failed. Replace thermal governor. Sweating. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 6. Maintenance 45 Maintenance Instructions CARE AND MAINTENANCE WARNING Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile flammable liquids near heater or in the same room with heater. 7KHIROORZLQJPDLQWHQDQFHLVUHFRPPHQGHGHYHU\VL[PRQWKVDQGDWWKHVWDUWRIHYHU\VZLPPLQJVHDVRQ ,QVSHFWWKHKHDWHUSDQHOVDQGYHQWLQJV\VWHPWRPDNHVXUHWKDWWKHUHDUHQRREVWUXFWLRQVWRWKHÀRZRIYHQWLODWLQJDLU RUEXUQHUH[KDXVW&KHFNWKDWURRPDLULQWDNHVDUHRSHQDQGFOHDURIREVWUXFWLRQV .HHSWKHDUHDLQDQGDURXQGWKHKHDWHUFOHDUDQGIUHHIURPFRPEXVWLEOHPDWHULDOVJDVROLQHDQGRWKHUÀDPPDEOH YDSRUVDQGFRUURVLYHOLTXLGV 7HVWWKHRSHUDWLRQRIWKHSUHVVXUHUHOLHIYDOYHE\OLIWLQJWKHYDOYHOHYHULILQVWDOOHG 7HVWIRUSURSHURSHUDWLRQRIWKHZDWHUSUHVVXUHVZLWFK6HH³:$7(535(6685(6:,7&+´SDJHIRUWHVWLQJ LQVWUXFWLRQV 2QHQFORVHGLQVWDOODWLRQVZLWKKLJKWHPSHUDWXUH6SHFLDO*DV9HQWV\VWHPVUHSHDWWKH³)LQDO,QVWDOODWLRQ&KHFN´SDJH &KHFNIRUHYLGHQFHRIMRLQWOHDNDJH0DNHVXUHWKDWMRLQWVKDYHQRWVOLSSHGSDUWLDOO\RUFRPSOHWHO\DSDUW&KHFN SLSHDQG¿WWLQJVIRUFUDFNVRUEUHDNV7KHFRPEXVWLRQDLUEORZHULVSHUPDQHQWO\OXEULFDWHGDQGGRHVQRWUHTXLUH SHULRGLFOXEULFDWLRQ7KHEXUQHUGRHVQRWUHTXLUHPDLQWHQDQFHRUDGMXVWPHQWE\WKHXVHU&DOODTXDOL¿HGVHUYLFH WHFKQLFLDQLI\RXVXVSHFWWKDWWKHEXUQHUPD\UHTXLUHPDLQWHQDQFH WARNING Explosion hazard. Any heater installed with restrictive devices in the piping system downstream from the heater, (including check valves, isolation valves, flow nozzles, or therapeutic pool valving), must have a relief valve installed as described above. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 46 Section 6. Maintenance AFTER START-UP CHECKING WATER FLOW WARNING Fire or flooding hazard. If the unit overheats and the burner fails to shut off, follow instructions under “To Turn Off Gas to the Appliance”, page 33, and call a qualified service technician to repair unit. $IWHUVWDUWXSWKHRXWOHWZDWHUSLSHVKRXOGIHHOVOLJKWO\ZDUPHUWKDQWKHLQOHWSLSH,ILWIHHOVKRWRULI\RXKHDUWKHZDWHULQWKHKHDWHU ERLOLQJWKHUHPD\QRWEHHQRXJKZDWHUÀRZWRWKHDSSOLDQFH0DNHVXUHWKDWWKH¿OWHULVQRWSOXJJHG,IZDWHUWHPSHUDWXUHUHPDLQV KLJKEXWWKHXQLWFRQWLQXHVWRRSHUDWHWXUQRIIWKHDSSOLDQFHDQGFDOO\RXUVHUYLFHWHFKQLFLDQ SPRING AND FALL OPERATION ,IWKHSRROLVRQO\XVHGRFFDVLRQDOO\ORZHUWKHSRROWKHUPRVWDWWR)&DQGOHDYHWKHKHDWHURQ7KLVZLOONHHSWKHSRRODQG WKHVXUURXQGLQJJURXQGZDUPHQRXJKVRWKDWWKHKHDWHUVKRXOGUHVWRUHWKHSRROWRDFRPIRUWDEOHWHPSHUDWXUHZLWKLQDERXWRQHGD\ WINTER OPERATION CAUTION s /PERATINGTHISHEATERCONTINUOUSLYATWATERTEMPERATURESBELOW½F. (20° C) will cause harmful condensation and will damage the heater and void the warranty. s )FTHEHEATERHASBEENDRAINEDFORFREEZINGCONDITIONDO./4TURNh/.vUNTILTHESYSTEMISCIRCULATINGWATER s Water trapped in the heat exchanger can result in freeze damage to the exchanger or headers. Freeze damage is specifically not covered by the warranty. s 7HENSTARTINGTHEHEATERFORTHESWIMMINGSEASONWITHAWATERTEMPERATUREBELOW½&½#THEHEATERMAYBEUSED to heat the water; however, make sure that the heater operates continuously until the water temperature reaches the heater’s minimum setting of 68° F (20° C). During cold weather, if there is no danger of freezing, operate the filter pump continuously even if the heater is not operating. If air temperatures are expected to drop below freezing (32° F/0° C), shut down the heater and winterize it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¿WWLQJZLWKORZSUHVVXUHFRPSUHVVHGDLUOHVVWKDQ36,RUN3D WARNING Explosion hazard. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI or 35 kPa), high volume blower when air purging the heater, pump, filter, or piping. 5HPRYHWKH:DWHU3UHVVXUH6ZLWFK3OXJWKHSRUWLQWKHPDQLIROGWRSUHYHQWEXJVDQGGLUWIURPJHWWLQJLQWRWKHPDQLIROG 'UDLQWKHSODVWLFLQOHWRXWOHWPDQLIROGWKURXJKWKHRXWOHWSLSH,IWKHSLSHGRHVQRWGUDLQQDWXUDOO\WRWKHSRROLQVWDOODGUDLQFRFN LQWKHRXWOHWSLSHWRGUDLQWKHPDQLIROG &RYHUDLULQOHWJUDWHZLWKDSODVWLFEDJWRSUHYHQWEXJVOHDYHVHWFIURPJHWWLQJLQWRWKHKHDWHU NOTICE:Water trapped in the heater can cause freeze damage. Allowing the heater to freeze voids the warranty. 7RUHWXUQWKHKHDWHUWRVHUYLFHDIWHUZLQWHUL]LQJ &RQQHFWWKH,1/(7DQG287/(7XQLRQVWRWKHV\VWHPSOXPELQJ&KHFNWKDWWKH\DUHFRQQHFWHGFRUUHFWO\DQGWKHUHDUHQRZDWHU OHDNV %HIRUHVWDUWLQJWKHKHDWHUFLUFXODWHZDWHUWKURXJKWKHKHDWHUIRUVHYHUDOPLQXWHVXQWLODOODLUQRLVHVVWRS6HHDOVR³%()25( 67$5783´SDJHDQG³&$5($1'0$,17(1$1&(´SDJH (See additional notes under Important Notices in Introduction.) MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 6. Maintenance 47 MAINTAINING POOL TEMPERATURE 7RPDLQWDLQSRROWHPSHUDWXUHPDNHVXUHWKDWWKHKHDWHUVZLWFKDQGYDOYHVDUHUHVHWWRSRROVHWWLQJVDIWHUXVLQJWKHVSD ENERGY SAVING TIPS .HHSWKHSRRORUVSDFRYHUHGZKHQQRWLQXVH7KLVZLOOUHGXFHKHDWLQJFRVWVUHGXFHZDWHUHYDSRUDWLRQFRQVHUYH FKHPLFDOVDQGUHGXFHORDGRQWKH¿OWHULQJV\VWHP 5HGXFHSRROWKHUPRVWDWWR)&RUORZHUUHGXFHVSDWHPSHUDWXUHWR)&7KLVLVDFFHSWHGDV EHLQJWKHPRVWKHDOWK\WHPSHUDWXUHIRUVZLPPLQJE\WKH$PHULFDQ5HG&URVV 8VHDWLPHFORFNWRVWDUWWKH¿OWHUSXPSDWDPRUODWHU7KHVZLPPLQJSRROORVHVOHVVKHDWDIWHUGD\EUHDN )RUSRROVXVHGRQO\RQZHHNHQGVORZHUWKHWKHUPRVWDWVHWWLQJE\)WR)&WR&GXULQJWKHZHHNWR UHGXFHKHDWORVV$SURSHUO\VL]HGKHDWHUZLOOUHVWRUHQRUPDOWHPSHUDWXUHZLWKLQRQHGD\ 7XUQWKHKHDWHURIIZKHQWKHSRROZLOOQRWEHXVHGIRUDQH[WHQGHGSHULRG )ROORZDUHJXODUSURJUDPRISUHYHQWLYHPDLQWHQDQFHIRUWKHKHDWHUHDFKQHZVZLPPLQJVHDVRQ&KHFNRSHUDWLRQRI WKHKHDWHUDQGLWVFRQWUROV CHEMICAL BALANCE POOL AND SPA WATER <RXUSRROKHDWHUZDVGHVLJQHGVSHFL¿FDOO\IRU\RXUVSDRUSRRODQGZLOOJLYH\RXPDQ\\HDUVRIWURXEOHIUHHVHUYLFH SURYLGHG\RXNHHS\RXUZDWHUFKHPLVWU\LQSURSHUFRQGLWLRQ :DWHUFKHPLVWU\VKRXOGIROORZJRRGVZLPPLQJSRROZDWHUFKHPLVWU\SUDFWLFHV:KHQXVLQJDFKORULQDWRULQVWDOOLWGRZQ VWUHDPIURPWKHKHDWHUDQGDWDORZHUOHYHOWKDQWKHKHDWHURXWOHW,QVWDOODFRUURVLRQUHVLVWDQWSRVLWLYHVHDO³&KHFN9DOYH´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eat exchanger damage resulting from chemical imbalance is not covered by the warranty. WHAT A DISINFECTANT DOES 7ZRSRROJXHVWV\RXGRQRWZDQWDUHDOJDHDQGEDFWHULD7RJHWULGRIWKHPDQGPDNHSRROZDWHUVDQLWDU\IRUVZLPPLQJ DVZHOODVWRLPSURYHWKHZDWHU¶VWDVWHRGRUDQGFODULW\VRPHVRUWRIGLVLQIHFWDQWPXVWEHXVHG &KORULQHDQGEURPLQHDUHXQLYHUVDOO\DSSURYHGE\KHDOWKDXWKRULWLHVDQGDUHDFFHSWHGGLVLQIHFWLQJDJHQWVIRUEDFWHULD FRQWURO WHAT IS A DISINFECTANT RESIDUAL? :KHQ\RXDGGFKORULQHRUEURPLQHWRWKHSRROZDWHUDSRUWLRQRIWKHGLVLQIHFWDQWZLOOEHFRQVXPHGLQWKHSURFHVV RIGHVWUR\LQJEDFWHULDDOJDHDQGRWKHUR[LGL]DEOHPDWHULDOV7KHGLVLQIHFWDQWUHPDLQLQJLVFDOOHGFKORULQHUHVLGXDORU EURPLQHUHVLGXDO<RXFDQGHWHUPLQHWKHGLVLQIHFWDQWUHVLGXDORI\RXUSRROZDWHUZLWKDUHOLDEOHWHVWNLWDYDLODEOHIURP \RXUORFDOSRROVXSSO\VWRUH <RXPXVWPDLQWDLQDGLVLQIHFWDQWUHVLGXDOOHYHODGHTXDWHHQRXJKWRDVVXUHDFRQWLQXRXVNLOORIEDFWHULDRUYLUXVLQWURGXFHG LQWRSRROZDWHUE\VZLPPHUVWKURXJKWKHDLUIURPGXVWUDLQRURWKHUVRXUFHV Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 48 Section 6. Maintenance CHEMICAL BALANCE (continued) ,WLVZLVHWRWHVWSRROZDWHUUHJXODUO\1HYHUDOORZFKORULQHUHVLGXDOWRGURSEHORZSSPSDUWVSHUPLOOLRQ7KH PLQLPXPOHYHOIRUHIIHFWLYHFKORULQHRUEURPLQHUHVLGXDOLVSSP pH7KHWHUPS+UHIHUVWRWKHDFLGDONDOLQHEDODQFHRIZDWHUH[SUHVVHGRQDQXPHULFDOVFDOHIURPWR$WHVWNLWIRUPHDVXULQJ S+EDODQFHRI\RXUSRROZDWHULVDYDLODEOHIURP\RXUORFDOSRROVXSSO\VWRUHVHH7DEOH 0XULDWLF$FLGKDVDS+RIDERXW3XUHZDWHULVQHXWUDO:HDN/\HVROXWLRQKDYHDS+RI 58/(WRLVDGHVLUDEOHS+UDQJH,WLVHVVHQWLDOWRPDLQWDLQFRUUHFWS+VHH7DEOH If pH becomes too high (over alkaline), it has these effects: *UHDWO\ORZHUVWKHDELOLW\RIFKORULQHWRGHVWUR\EDFWHULDDQGDOJDH :DWHUEHFRPHVFORXG\ 7KHUHLVPRUHGDQJHURIVFDOHIRUPDWLRQRQWKHSODVWHURULQWKHKHDWH[FKDQJHUWXELQJ )LOWHUHOHPHQWVPD\EHFRPHEORFNHG )FP(ISTOOLOWOVERACIDTHEFOLLOWINGCONDITIONSMAYOCCUR ([FHVVLYHH\HEXUQRUVNLQLUULWDWLRQ (WFKLQJRIWKHSODVWHU &RUURVLRQRIPHWDO¿[WXUHVLQWKH¿OWUDWLRQDQGUHFLUFXODWLRQV\VWHPZKLFKPD\FUHDWHEURZQEOXHJUHHQRUVRPHWLPHVDOPRVW EODFNVWDLQVRQWKHSODVWHU &RUURVLRQRIFRSSHUWXEHVLQWKHKHDWHUZKLFKPD\FDXVHOHDNV ,I\RXKDYHDVDQGDQGJUDYHO¿OWHUWKHDOXPXVHGDVD¿OWHUDLGPD\GLVVROYHDQGSDVVWKURXJKWKH¿OWHU CAUTION: Do not test for pH when the chlorine residual is 3.0 ppm or higher, or bromine residual is 6.0 ppm or higher. See your local pool supply store for help in properly balancing your water chemistry. 58/(&KHPLFDOVWKDWDUHDFLGORZHUS+&KHPLFDOVWKDWDUHDONDOLQHUDLVHS+ !,+!,).)49(IGHOR,OW ³7RWDODONDOLQLW\´LVDPHDVXUHPHQWRIWKHWRWDODPRXQWRIDONDOLQHFKHPLFDOVLQWKHZDWHUDQGFRQWUROS+WRDJUHDWGHJUHH,WLV QRWWKHVDPHDVS+ZKLFKUHIHUVPHUHO\WRWKHUHODWLYHDONDOLQLW\DFLGLW\EDODQFH<RXUSRROZDWHU¶VWRWDODONDOLQLW\VKRXOGEH SSPWRSHUPLWHDVLHUS+FRQWURO $WRWDODONDOLQLW\WHVWLVVLPSOHWRSHUIRUPZLWKDUHOLDEOHWHVWNLW<RXZLOOQHHGWRWHVWDERXWRQFHDZHHNDQGPDNHSURSHUDGMXVWPHQWV XQWLODONDOLQLW\LVLQWKHSURSHUUDQJH7KHQWHVWRQO\RQFHHYHU\PRQWKRUVRWREHVXUHLWLVEHLQJPDLQWDLQHG6HH\RXUORFDOSRRO GHDOHUIRUKHOSLQSURSHUO\EDODQFLQJWKHZDWHUFKHPLVWU\ WATER CHEMISTRY PARAMETERS Disinfectant levels Minimum Ideal Maximum Free Chlorine, ppm 1.0 2.0-4.0 5.0** Combined Chlorine, ppm None None 0.2 Bromine, ppm 2.0 4-6 10.0 Other Sanitizers Levels not established. Consult local health department before use. Chemical Values pH 7.2 7.4-7.6 7.8** Total Alkalinity (Buffering), ppm 60 80-100 180 as CaCO3 Salt ppm 2000 3200 5000** Total Dissolved Solids, ppm N/A N/A 1,500 ppm > TDS at startup* Calcium Hardness, ppm, as CaCO3 150 200-400 500-1,000 Heavy Metals None None None Biological Values Algae None None None Bacteria None None Refer to Local Code *Start-up TDS includes source water TDS and any other inorganic salt added at start-up. Table 7. NOTE (**): Failure to adhere to the listed water chemistry parameters may result in premature failure of the heat exchanger and will VOIDTHEWARRANTY. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 6. Maintenance/Replacement Parts 49 MasterTemp® 125 HEATER REPLACEMENT PARTS 1 For complete Electrical System parts breakdown (Key Nos. 1 through 4), See Page 53 For complete Burner System parts breakdown (Key Nos. 5 through 7), See Page 51 2 7 5 6 3 9 4 8 For complete Water System parts breakdown (Key Nos. 8 through 9), see Page 52 Repair Parts are available from your Pentair dealer. If your dealer cannot supply you, call Customer Support at 1-800-831-7133. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 50 Section 6. Maintenance/Replacement Parts MasterTemp® 125 HEATER REPLACEMENT PARTS 22 1 8 9 2 21 10 3 4 7 11 6 5 12 14 20 19 18 26 27 13 23 17 16 15 24 23 25 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 6. Maintenance/Replacement Parts 51 MASTERTEMP® 125 HEATER REPLACEMENT PARTS REPAIR PARTS – BURNER SYSTEM Model Key Part No. Description Qty. MT125 NA MT125 LP 1 Combination Gas Control Valve Kit 1 42001-0051S 2 3/4" Union 2 38404-4097S 3 Gas Orifice 1 4 Gas Orifice O-Ring 1 F as Orifice Kit – NG (Incl. Key Nos. 3 and 4)† 474981 F as Orifice Kit – Propane (Incl. Key Nos. 3 and 4)† 474980 F "G to Propane Conversion Kit F $ropane to NG Conversion Kit 461063 (Incl. Key Nos. 3 and 4)† 461062 (Incl. Key Nos. 3 and 4)† 5 Air Blower Kit Natural Gas Units 1 474978 Propane Units 1 474977 474979 F ir Orifice Kit (Includes Key Nos. 6 and 7) 1 6 Air Orifice Kit 1 7 Air Orifice Grill F lower/Adapter Plate Gasket Kit (Includes Key Nos. 8, 9, 10, 12) F 1 77707-0011 1 474994 lameholder Kit (Includes Key Nos. 10, 11, 12, 13) 8 Blower/Adapter Plate Gasket 1 9 Blower Adapter Plate 1 10 5+6/285./: .+9</:Plate Gasket 1 11 5+6/285./:Assembly 1 12 5+6/285./: 86,=;<387Chamber Gasket* 1 13 5+6/285./: Insulation Cap 1 F lameholder Insert 1 14 Combustion Chamber Gasket Kit 1 474952 15 One Piece Metal Chamber/Combustion Chamber Assembly (9-bolt) 1 474990 F nsulation Kit (Includes Key No. 13, 16,17,18,19) 1 77707-0008 16 Bottom Outer Insulation Blanket* 1 17 1" Bottom Inner Insulation 1 18 1" Top Insulation 1 19 Top Outer Insulation Blanket* 1 F Lower Enclosure Insulation 1 42001-0074S 20 One Piece Metal Elbow/Combustion Chamber Cover Assembly (9-bolt) 1 474958 Metal Vent Cover 1 42002-0005S 22 Heater Top 1 42002-0034Z 23 Side Panel {Service Panel} 1 474991 21 24 Side Panel {Manifold} 1 25 Heater Bottom 1 26 &3./$+7/5B5=/&<+-4C 1 27 J-Box Cover 1 28 F Screws/Clips Kit, Panel (8 ea. clips & 8 ea. screws) Combustion Air Intake Duct Connection Kit 1 1 * 474992 42002-0031Z 474993 42002-0041Z 474292 CALL Not available separately. ** Not included with heater. Order separately. Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 52 Section 6. Maintenance/Replacement Parts MASTERTEMP® 125 HEATER REPLACEMENT PARTS 1 3 4 2 5 12 6 13 8 14 9 7 10 11 REPAIR PARTS – WATER SYSTEM Model Key No. Part Description 1 Tube Sheet Coil Assembly Kit (NA, LP) (Includes Key No.3) 2 M anifold Kit (Includes Key Nos. 3-11. Key No.12 and 13 not included. Key Nos. 5-7 in “Electrical System”, Page 53 3 4 5 Coil/Tubesheet Sealing O-Ring Kit Manifold Bottom Plate (*) 6 7 8 9 10 11 Manifold O-Ring (*) Manifold Baffle Plate (*) M anifold Bypass Valve (*) Water Pressure Switch Manifold (*) 5/16" Washer, Stainless Steel (*) 5/16x18x2-3/4" Hex Cap screw (*) 12 Thermal Regulator 13 Pressure Relief Valve (Recommended (Purchase Separately) 14 1-1/2” Union Kit Qty. MT125 NA MT125 LP 1 474971 1 1 1 1 1 1 1 1 6 6 1 1 1 474972 474973 42001-0060S 474989 473715Z 474974 (*) Not available separately MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 Section 6. Maintenance/Replacement Parts 53 MASTERTEMP® 125 HEATER REPLACEMENT PARTS 1 15 14 13 2 3 16 4 11 10 6 5 7 12 8 7a 9 REPAIR PARTS – ELECTRICAL SYSTEM Key No. Rev. B 8/14 Qty. Model 125 (NA/LP) 1 Heater Display Cover 1 42002-0035 2 Igniter Bracket 1 42001-0030S 3 Igniter/Igniter Gasket Kit Incl. Key Nos. 3 and 4) 1 77707-0054 4 Igniter Gasket 1 42001-0066S 5 Automatic Gas Shutoff Switch (AGS) 1 474368S 6 High Limit Switch 1 474367S 7 7a Thermistor Hi-Limit Switch 45° C 1 1 42001-0053S 8 Terminal Board 1 42001-0056S 9 Fireman’s Switch Fuse (1.25A, 1-1/4") 1 32850-0099 10 Ignition Control Module 1 42001-0052S 11 Transformer, 120/240V 1 42001-0107S MT125 HD NA & LP (International) 474369S 55° C HI LIMIT 175147S 474103S 12 Air Flow Switch 1 42001-0061S 13 Control Board Kit (NA, LP Series) 1 42002-0007S = Heater Wiring Harness - 120/240V 1 42001-0104S 474163S = 120/240 Volt Plug Kit 1 42001-0105S 473764S (240 V PLUG) Heater, Top 1 42002-0034Z 14 = Part Description 15 Membrane Pad (NA, LP Series) 1 472610Z 16 Stack Flue Sensor 1 42002-0024S ot available separately. MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 54 NOTES MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14 55 NOTES Rev. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide 56 +$:.,16$9(6$1)25'1&ɒ :(67/26$1*(/(6$9(02253$5.&$ɒ www.pentairpool.com All Pentair trademarks and logos are owned by Pentair or by one of its global affilliates. Pentair Aquatic Systems™, MasterTemp®, IntelliTouch®, EasyTouch®, are trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. © 2014 Pentair Water Pool and Spa, Inc. All rights reserved. This document is subject to change without notice. P/N 475000 REV. B 8/14 MASTERTEMP® 125 Pool and Spa Heater Installation and User’s Guide Rev. B 8/14