Industrial Electrical and Automation Products, Systems and Solutions PART D CATALOGUE D AUTOMATION PRODUCTS PLCs 01 Fieldbus I/O Systems Operator Panels & Touch Screens Visualisation & Reporting Software Switch Mode Power Supplies SAFETY 02 Safety, Interlock, Limit & Trip-Wire Switches Non-contact Safety Switches Emergency stop trip-wire switches Safety Controllers Sales 1300 NHP NHP | nhp.com.au Industrial Limit & Foot Operated Switches SOFT STARTERS & DRIVES Soft Starters Variable Speed Drives 03 NHP Electrical Engineering Products NHP NATIONAL MANUFACTURING AND DISTRIBUTION CENTRE NHP Electrical Engineering Products (NHP) specialises in motor control, power distribution and automation systems. NHP offers the Australasian market the complete industrial electrical and automation solutions package. As authorised distributors for Rockwell Automation and their Allen-Bradley® products in our designated areas of Australia and throughout all of New Zealand, NHP is partnered with the leading global provider of industrial automation solutions and switchgear components. An Australian owned company, NHP is committed to serving the Australasian industry with quality products and customer support. This is achieved through a 1000+ strong team which is distributed across 25 branches and 24 regional locations throughout Australia and New Zealand. While NHP stock an impressive 45,000+ line items, we are much more than a component supplier. NHP source the highest quality products from leading global suppliers, and customise these into solutions for the local Australian and New Zealand markets, providing a complete fit to purpose systems and solutions service. Scan the QR code for career opportunities at NHP At NHP we have a strong customer focus and we look to provide the right product and product solutions for our customers’ requirements and applications, all at a competitive price. We value and care for our customers and support them by offering personalised service and assistance to meet their every need and demand. Our customers can have 100% confidence in our ability to support them when, where and how it is needed. Please scan the QR code to view our corporate presentation. Put simply, NHP is ‘easy to do business with’. PARTNERSHIPS KNOWLEDGE AGILITY “Corporate DNA” The NHP Value Proposition 2 SCALE PLCs Fieldbus I/O Systems Operator Panels and Touch Screens Visualisation and Reporting Software Switch Mode Power Supplies 1 SAFETY Safety, Interlock, Limit and Trip-Wire Switches Safety Controllers Industrial Limit Switches Foot Operated Switches 2 SOFT STARTERS & DRIVES Soft Starters Variable Speed Drives 3 Quick Reference Index AUTOMATION PRODUCTS Explanation of Terms EXPLANATION OF TERMS AND HEADINGS USED WITHIN THIS CATALOGUE This catalogue is segregated into sections. The first page of each section has its own contents page for easier product selection. For pricing refer to the relevant price list, e.g. to find prices for parts in the Part D Catalogue, refer to the Part D Price List. Each page has a bold section number for prompt page location. Parts that are available on indent only or parts that are assembled to order will be identified in the relevant price list. Each page is identified by both its section number and its page number eg. 2-8 signifies this is section 2 page 8. Please make sure you have the most current price list for each catalogue. Contact your NHP Sales Representative or refer to www.nhp.com.au to obtain a copy of the most current price list. Three indexes in each catalogue make finding products easy; A product listing is situated at the front of this catalogue. A complete section contents listing is situated at the front of the catalogue. Current NHP standard conditions of sale apply to this price list catalogue. An alphanumeric index is situated at the rear of this catalogue. All catalogue numbers are bold and shaded. TYPICAL PAGE LAYOUT Section number Page contents Emergency stop trip-wire switch “kits” Series TQ ZS: Trip-wire switches Emergency stop for conveyor and various other industries Description of product, ratings etc. TQZS70...8 metres Slim housing Trip-wire Switch 2 Trip-wire length TQZS70... kit TQZS70101SVD Items included in kit 1) Cat. No Price $ 1 x TQZSTS150N 8 metres TQZS-70 8 x TQZSWR5MM (cable) TQZS70KIT10M 383.88 TQZS71KIT20M 581.00 TQZS73KIT50M 1006.38 TQZS75KIT50M 1130.88 TQZS80KIT50M 975.25 3 x 55150 (wire support) TQZS71...5-20 metres Small housing TQZS71... kit TQZS71101 Illustrative photographs or diagrams indicative of products available (not necessarily to scale) Cat. No. of product is always next to the applicable price. 1 x TQZSTS250N 20 metres 20 x 55153P (cable) The catalogue numbers are shaded for quick identification. 5 x 55150 (wire support) TQZS-71... TQZS73...30-50 metres General purpose TQZS73... kit TQZS3101SWVD 1 x TQZSTS250N (spring) 50 metres 50 x 55153P (cable) 10 x 55150 (wire support) TQZS-73... TQZS-75...30-50 metres Large housing TQZS75... kit TQZS75101SWVD 1 x TQZSTS250N (spring) 50 metres 50 x 55153P (cable) Footnotes, as necessary, are referenced to the bottom of each page. E.g. 2) 10 x 55150 (wire support) TQZS-75... TQZS80...10-50 metres With emergency stop and flag indicator TQZS80... kit Price Schedule(s) listed for products on this page. TQZS80202SWVD 1 x TQZSTS250N (spring) 50 metres 50 x 55153P (cable) 10 x 55150 (wire support) TQZS-80 Notes: Section and page number e.g. section 2, page 8 14 Price Schedule ‘B2’ 2-8 Additional information, accessories, technical data, notes, etc. ) Items included in all of the above kits 1 x Tension spring (As per requirement AS 1755-2000) 1 x 55164, turnbuckle 4 x 55151, thimble 8 x 55152, wire clamps _ x Cable (quantity as above) _ x 55150, wire support (quantity as above) Wire supports are based upon supporting the trip-wire at 2.5 - 3 metre intervals. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Product Sub Product Section Page F Fieldbus I/O systems for industrial automation applications 2 2 2 2 19 17 15 13 750 Series 750 Series Intrinsically safe system 750 Series PROFIsafe system 750 Series Starter kits 750 Series Vibration monitoring 751 Series AS-i Fieldbus system 753 Series Quick connect 1 1 1 1 1 1 1 21 28 29 34 28 30 35 857 Series JUMPFLEX Transducers Overview Programming and diagnostic software Ordering details 1 1 1 1 26 16 31 42 1 38 Light duty 6 A: ES/EM 95 series Medium duty 10 A: PS21 series Medium duty 10 A: PS31 series Medium Duty 6 A:ES/EM 41 series 2 2 2 2 11 11 12 12 Introduction to CA 8 2.2 - 5.5 kW compact contactor system Mounting rail - to suit DIN style equipment Safety contactors CAS - AC and DC operated 4 - 500 kW 1 1 1 4 37 18 Hitachi EH Micro series 1 6 Mitsubishi Alpha 2 series 1 2 Hitachi EH-150 series 1 10 Micro and modular PLC accessory selection guide 1 15 Belt drift switches 2 10 Emergency stop trip-wire switch kits Emergency stop trip-wire switches Series BZ16 Series HSSi4 Series RC Si - 56 Series RC Si - M30 2 2 2 2 2 2 8 9 7 7 6 6 1 1 1 1 1 1 1 1 54 56 51 52 49 48 50 55 2 2 2 2 2 2 22 21 23 20 20 20 Fieldbus I/O systems for long distance, lighting Overview and irrigation control systems L Limit switches M Micro Programmable Logic Controllers Modular Programmable Logic Controllers N Non-contact Safety switches O Operator panels Communications cables and touch Dimensions and cut-outs Graphics operator panels screens Graphics touch screens Overview SC 207 Text based operator panels VTWIN Configuration software S Safety Controllers Foot operated switches Limit switches - pull-wire (non safety) Pressure switches Series MF1: Standstill monitor Series NSC: Fail safe control unit Series SRM: Fail safe control unit Product Listing E Emergency stop Heavy-duty limit switches: 77 HL and 77 TL series trip-wire switches Installation instructions Spare parts and accessories Type NTW cast aluminium Product Listing Product Sub Product Section Page Safety interlock switches Series AZM 415: Heavy duty Solenoid 2 5 Series ES - 13SB: Light duty hinged Series ES - 95: General purpose Series ES - 95: General purpose flap/hinge 2 2 2 4 2 4 Series ES - 95: General purpose rotary cam Series ST - 14: Light duty Series ST - 61: Heavy Duty Series STM 295: Medium duty solenoid CSX and CSXi - introduction, specifications and ordering details Electronic soft starters product selection guide EMX3 - introduction, specifications and ordering details PCS - introduction, specifications and ordering details 2 2 2 2 3 3 3 3 4 2 3 5 7 2 12 4 Switch mode power supplies 1 68 Brake resistor selection by duty cycle Brake resistors and accessories - ordering details Input and output choke - ordering details Product selection guide Rating and selection chart Santerno SINUS Nano range - introduction, standard specifications and ordering details Semiconductor fuses and accessories - ordering details SINUS Micro range - introduction, standard specifications and ordering details SINUS Nano and Micro ranges - options SINUS Penta - multi-pump application and SINUS Penta - options SINUS Penta - range and selection (380 - 415 V) SINUS Penta - range and selection (660 - 690 V) SINUS Penta - specifications SINUS Penta range - introduction, standard specifications and options Ordering details 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 37 38 35 23 40 24 36 25 26 46 48 32 44 49 27 66 1 59 Soft starters Switch mode power supplies V Variable Speed Drives Visualisation and reporting software Overview - World class 32-bit SCADA/HMI software 3 NHP’s Values To achieve our vision, NHP has six values which define how we operate Passion for Customers Energy An energetic “can and will do” attitude and approach. Enthusiasm is infectious and we look to provide this in all aspects of our business and our customers’ business. Without customers we have no business, so we are passionate about everything we do for them. We service our customers’ needs 24 hours a day, 7 days a week, 365 days a year. Adaptiveness to Change If we don’t adapt, we wither then die. While we have adhered to the same values and service objectives since day one, we also have adapted to the changing face of our industry and the industrial world, and we look to help our customers prosper as a result. Integrity Consistency We do what is right for our customers, our staff, our industry and our community. We provide our customers with what they want, when, where and how they want it, for today, tomorrow and into the future. Commitment to Performance We aim to provide products and solutions on time, in full, every time. Our customers can expect to receive service above their expectations in everything we do. Australia and New Zealand Manufacturing and Distribution Centre NHP prides itself on being able to provide customers with tailored solutions that suit their individual needs. Whilst we have significant stockholdings and expertise at all our locations throughout Australia and New Zealand, the purpose of our National Manufacturing and Distribution Centre in Laverton, Melbourne is to develop these solutions through manufacturing, assembly, servicing and design and engineering. SIZE Warehouse 7,000 m2 Manufacturing 5,000 m2 STAFF 270+ Employees OPERATING HOURS 6.00am - 11.30pm, Monday-Friday STOCKHOLDING - 45,000+ line items (20,000 stocked) - Approximately $70 M ITEM THROUGHPUT - Approximately 5,500 per day (6,000 lines throughout Australasia) FACTS r 0SEFSTSFMFBTFEGPSQJDLJOHCFGPSF 3.00 pm are despatched the same day. AUSTRALIA AND NEW ZEALAND MANUFACTURING AND DISTRIBUTION CENTRE r 5IF4VQQMZ$IBJOUFBNTUSJWFTUPBDIJFWF 95 % customer service based on an ‘on time in full, first time’ measurement. 2011 n Laverto Facilit y Tour Book let Scan the QR code to view the Laverton Tour brochure. Scan the QR code to view our Concept Express video Sustainability Centre Emerging technology supporting sustainability Learning to use energy smarter to reduce our consumption and increase one’s bottom line is now a key consideration in all applications. NHP are also proud participants in the Victorian Government’s electric vehicle trial. The trial will provide NHP with valuable insights to assist in future business planning, as well as help the wider community understand the process, timelines and barriers for transitioning to electric vehicle technologies in the future. A major focus at NHP is to provide sustainable solutions for our customers as well as throughout our own operations. Early in 2010 we designed and constructed our very own Sustainability Centre - located at our existing National Manufacturing and Distribution Centre in Laverton, Melbourne. NHP’s Sustainability Centre and participation in the electric vehicle trial highlight our commitment to encourage sustainable practices across all facets of the workplace. Our aim is to remain at the forefront of the industry, as leaders in providing alternative energy solutions for commercial and industrial applications. The Centre utilises cutting edge technology and houses equipment which enables us to conduct research & development, test new products and look closely at ways we can effectively introduce and manage sustainable practices. NHP also works closely with Melbourne University, RMIT University and Victoria University, providing course advice and industry based supervision of undergraduate and postgraduate students. A major push towards more sustainable practices by many in the industrial electrical industry is now clear for all to see in today’s environment. The centre is driven by power generated from Solar Panels and houses an interactive display allowing visitors a close-up view of a range of sustainable energy technologies which currently include: r A horizontal axis wind generator r Solar photo-voltaic systems r Grid interactive systems r Off-grid hybrid systems r Dual axis solar tracker, and r Energy Management & control systems NHP is proud to educate young electrical engineers in this growing, and important industry sector. ONE OF NHP’S ELECTRIC CARS ON DISPLAY AT THE SUSTAINABILITY CENTRE IN LAVERTON, MELBOURNE Scan the QR code to view a video on our electric car trial. Scan the QR code to Book a Live Tour. Products and Brands To assist customers in finding what they want, we have classified our extensive product range into the following categories. AUTOMATION SYSTEMS Our vast automation product range can provide a completely integrated automation solution, for both the factory and process automation industries, that can be delivered with our Integrated Architecture platform. r.&44PGUXBSF r7JTVBMJTBUJPO4PGUXBSF r1SPDFTT$POUSPM4ZTUFNT r.PEVMBS1SPHSBNNBCMF Controllers r.JDSP$POUSPMMFSTBOE4NBSU Relays r%JTUSJCVUFE*04ZTUFNT r.PUJPO$POUSPMMFSTBOE4FSWP Drives r0QFSBUPS1BOFMTBOE5PVDI Screens r*OEVTUSJBM$PNQVUFST r/FUXPSLJOHBOE3BEJP Communications MOTOR CONTROL & DRIVES NHP offers conventional motor starting and protection products as well as advanced electronic starting, controlling and protection products to suit fractional horsepower motors through to large frame main drive systems. NHP also offers customised motor starters across the entire range. r"$$POUBDUPST r%$BOE5SBDUJPO$POUBDUPST r4UBOEBSE4UBSUFST r$VTUPNJTFE4UBSUFST r0WFSMPBE3FMBZT r5IFSNJTUPST r&MFDUSPOJD.PUPS1SPUFDUJPO3FMBZT r.PUPS1SPUFDUJPO$JSDVJU#SFBLFST r4PGU4UBSUFST r7BSJBCMF4QFFE%SJWFT r.77BSJBCMF4QFFE%SJWFT r-JRVJE3FTJTUBODF4UBSUFST POWER DISTRIBUTION & PROTECTION NHP provides Australasia’s widest range of low voltage power distribution and protection products supplied as components or as part of a manufactured solution. Circuit protection against current overloads up to 6300A is available together with a wide range of surge and arc protection, switching products and power supplies. r%JTUSJCVUJPO#PBSET r$JSDVJU#SFBLFST r4XJUDIFT r$IBTTJT4ZTUFNTBOECVTCBST r'VTFTBOE'VTFHFBS r&BSUI-FBLBHF1SPUFDUJPO r"SDBOE4VSHFQSPUFDUJPO r1BOFMCPBSETBOEMPBEDFOUSFT r$IBTTJT4ZTUFNTBOECVTCBST r*TPMBUPSTBOE5SBOTGFS4XJUDIFT r1PXFS4VQQMJFTBOEUSBOTGPSNFST ampcom GHISALBA MICROELETTRICA ERICO WOHNER SELCO POWER QUALITY NHP’s Power Quality products and systems provide solutions for power factor correction and harmonic mitigation. To meet specific customer requirements, this group of products are generally customised at our manufacturing centre in Laverton, Victoria. r1PXFS'BDUPS$PSSFDUJPO Systems r1PXFS'BDUPS$PSSFDUJPO Regulators r1PXFS$BQBDJUPST r)BSNPOJD'JMUFST r&.$'JMUFST r%7%5'JMUFST r4JOF'JMUFST r-JOF'JMUFST ENCLOSURES & CLIMATE CONTROL NHP has a complete range of mild steel, stainless and plastic enclosure options in a variety of IP ratings and configurations including modular switchboard systems. To complement NHP’s enclosure systems, a wide range of climate control solutions are also available. r.PEVMBS4XJUDICPBSE4ZTUFNT r*OTVMBUFE1MBTUJD&ODMPTVSFT r.JME4UFFM&ODMPTVSF4ZTUFNT r4UBJOMFTT4UFFM&ODMPTVSF4ZTUFNT r"JS$POEJUJPOFST r5IFSNPTUBUT r"OUJDPOEFOTBUJPO)FBUFST r)FBU&YDIBOHFST"JS"JS8BUFS"JS r(SJMMTBOE'JMUFST r'BOT ELECTRONICON BELUK TERMINATION & WIRING SYSTEMS NHP has a wide range of screw and screw-less terminals, terminal accessories (such a DIN rail and jumper pins) and cable ducting. r$BCMF%VDUT r%JO3BJMT r$BCMF(MBOET r5FSNJOBMT BOCCHIOTTI ERICO COSMOTEC STEGO IBOCO Products and Brands (cont’d) SIGNALLING DEVICES TIMERS & CONTROL RELAYS FIELD SWITCHING & SENSING NHP offers a range of control relays and timers that can be used in conjunction with a conventional automation system to switch higher loads or in stand alone applications where the only basic single function control is required. The automation system relies on information from the field to control the process. NHP’s switching and sensing suite of products cover all field sensing requirements including standard and hazardous area applications. r#FBDPOT r5JNF%FMBZ3FMBZT r1SFTTVSF4XJUDIFT r4PVOEFST r.POJUPSJOH3FMBZT r1IPUPFMFDUSJD4FOTPST r4JSFOT r5JNF$MPDL4XJUDIFT r1SPYJNJUZ4FOTPST r#V[[FST r4PMJE4UBUF3FMBZT r-FWFM4FOTPSBOE'MPBU4XJUDIFT r)PPUFST r4JOHMF-PPQ$POUSPMMFST r5FNQFSBUVSF4FOTPST With an extensive range of audible and visual signalling devices, NHP provides solutions for hundreds of applications, be it general safety warning, process control, fire or evacuation. r1JMPU-JHIUT r-JNJU4XJUDIFT r'MPX4XJUDIBOE4FOTPST r#FMMT r'JSF"MBSNT GRASSLIN PLUGS & SOCKETS OPERATOR R CONTROL DEVICES SAFETY PRODUCTS Divided into two distinct product ranges, NHP’s plugs and sockets provide solutions for a wide range of applications and are available in a wide range of amperages and pin configurations. Most processes, even if automated, still require some manual control and NHP provides a complete range of control products and systems for this purpose. NHP offer a large variety of quality safety products that meet international standards, with products ranging from simple emergency stop switches to safety monitoring relays. r1VTICVUUPOT r4BGFUZ4FSWJDFT r*OEVTUSJBMQMVHTTPDLFUT r$BN4XJUDIFT r4BGFUZ3FMBZTBOE$POUSPMMFST r*OEVTUSJBMJTPMBUJOHQMVHT sockets r1FOEBOU4ZTUFNT r/PODPOUBDU*OUFSMPDLT r+PZTUJDL$POUSPMMFST r4BGFUZ$POUBDUPSTBOE*TPMBUPST r1PSUBCMF$POUSPM4UBUJPOT r0QFSBUPS$POTPMFT r5SJQ8JSF4XJUDIFT r'PPU4XJUDIFT PROCONECT ELEKTRA SPOHN + BURKHARDT TER STEUTE Products and Brands (cont’d) HAZARDOUS AREA EQUIPMENT METERING NHP provided a world class range of hazardous area equipment for explosive environments including light fittings, enclosures and terminal boxes, control stations and intrinsically safe automation products. Energy Metering is the essential component to understanding your energy consumption and power quality. NHP has a complete range of energy meters and power quality analysers to meet the most demanding of applications. r-JHIUJOH r"OBMPHVFBOE%JHJUBM.FUFST r&ODMPTVSFTBOE5FSNJOBMT rL8I.FUFST r$POUSPMBOE4XJUDIHFBS r.VMUJGVODUJPO.FUFST r4JHIUBOE4PVOE r1PXFS2VBMJUZ"OBMZTFST r1MVHTBOE4PDLFUT r5SBOTEVDFST r3FNPUF*0).* r$VSSFOU5SBOTGPSNFST r4BGFUZ%FWJDFT r&OFSHZ.POJUPSJOH4PGUXBSF r$BNFSBT WAGO STEUTE RENEWABLE ENERGY PRODUCTS NHP offers a large selection of products and solutions tailored towards renewable energy applications including Solar and Wind. From high DC rated protection and switching devices, solar panel control and monitoring products through to a range of inverters and power factor correction systems. r4PMBS1BOFMT r8JOE5VSCJOFT r4PMBS1BOFM4USJOH1SPUFDUJPO and Control Boxes r4PMBS*OWFSUFST r%$.$#TBOE$POUBDUPST SERVICES & TRAINING SERVICES & TRAINING NHP has a wide range of services including technical support, field service and maintenance contracts, repair services and training. These services are delivered by NHP qualified technicians and our supply partners. r3FNBOVGBDUVSJOHBOE&YUFOEFE8BSSBOUZ r1BSUT.BOBHFNFOU"HSFFNFOUT r0O-JOFBOE1IPOF4VQQPSU r*OTUSVDUPS-FE5SBJOJOHBOE"TTFTTNFOUT r'JFME4FSWJDFBOE"TTFTTNFOUT r%SJWF4UBSU6QBOE/FUXPSL4FSWJDFT r$POWFSTJPOTBOE6QHSBEFT r$POEJUJPO.POJUPSJOH"VEJUTBOE"OBMZTJT Products and Brands (cont’d) 2. Application Classes HAZARDOUS AREA EQUIPMENT SAFETY When servicing important industries such as the oil and gas, petrochemical and grain handling there is no room for complacency. At NHP our aim is to provide a world class range of hazardous area equipment for the hazardous market which includes light fittings, terminal boxes, control stations and an extensive suite of automation products. NHP has been in this field for many years and has acquired a comprehensive knowledge on explosion protection products, so wherever explosive atmospheres are prevalent, NHP can provide the safest solution. For any industrial application, the safety of employees and the general population is of major importance. NHP has a long history in the safety industry and can be a trusted destination for all your safety application needs. NHP offer a large variety of quality products that meet all relevant international standards, with products ranging from simple emergency stop switches, to light curtains, safety monitoring relays all the way up to fully integrated safety PLC systems. Our product range extends further into SIL3 rated Safety Critical Shutdown systems. r-JHIUJOH r &ODMPTVSFTBOE5FSNJOBMT r $POUSPMBOE4XJUDIHFBS r 4JHIUBOE4PVOE r 1MVHTBOE4PDLFUT r 3FNPUF*0).* r 4BGFUZ%FWJDFT r $BNFSBT r )FMJEFDL&RVJQNFOU r .BSJOF-JHIUJOH r /BWJHBUJPO-JHIU4ZTUFNT r )B[BSEPVT"SFB"VUPNBUJPO r r r r r r r r r r 4BGFUZ4FSWJDFT 4BGFUZ3FMBZTBOE$POUSPMMFST 4BGFUZ1SPHSBNNBCMF$POUSPMMFST .FDIBOJDBM*OUFSMPDLT /PODPOUBDU*OUFSMPDLT 4BGFUZ.BUTBOE&EHFT -JHIU$VSUBJOT -BTFS4DBOOFST 5SBQQFE,FZ*OUFSMPDLT 4BGFUZ$SJUJDBM4IVUEPXO and Control Systems r 4BGFUZ$BNFSB4ZTUFNT r $POUBDUPST r 4BGFUZ*TPMBUPST WAGO STEUTE STEUTE KATKO PROCESS CONTROL Like the principles which drive the process industry, NHP is committed to delivering products of continuous quality to assist our customers in achieving process optimisation. Encompassing a wide range of industries including oil refining, petrochemicals, water and sewage treatment, food processing, and pharmaceuticals, the NHP process control product portfolio offers complete system integration. With first-hand experience and capabilities, and a solid understanding of the intensive continuous nature of Process operations, NHP reduces the risk associated with continuously achieving the business value promised by these technologies. In addition NHP continues to leverage from International relationships with recognised process control companies and experts, giving NHP access to a knowledge base which has consistently demonstrated its ability to deliver product quality, service and application knowledge. 3. Application Solutions ENERGY MANAGEMENT SUSTAINABILITY NHP can provide Energy Management Metering and Software solutions that monitor and record energy information so operators can identify consumption trends and take corrective actions. Realtime measurements of these electrical parameters, such as voltage variations or distortions, may have alarm thresholds set to warn managers if preset limits are reached. These real-time measurements also allow site managers to anticipate overload conditions that could, for example, trip a circuit breaker. NHP can provide a wide range of products to complement any Energy Management Solution. With an increasing focus on the state of global warming and the requirement to decrease our carbon footprint, the use of sustainability is becoming a popular phenomenon. Our partnerships with many of the industries best suppliers from around the world means that NHP offer a large selection of products and solutions tailored towards renewable energy applications including Solar and Wind. From high DC rated protection and switching devices, solar panel control and monitoring products through to a range of inverters and power factor correction, NHP has an extensive offering. r &OFSHZ.FUFST r 1PXFS"OBMZTFST r 4PMBS1BOFM4USJOH1SPUFDUJPO and Control Boxes r *OEVTUSJBM1$T r *OWFSUFST r *OEVTUSJBM).*T r %$$BCMFTBOE$POOFDUPST r $POUSPM4ZTUFNT r 4VSHF1SPUFDUJPO%FWJDFT r &OFSHZ.BOBHFNFOU4PGUXBSF r 1PXFS'BDUPS$PSSFDUJPO6OJUT r %$.$#TBOE$POUBDUPST Section Contents Listing 1 Automation products, PLCs, I/O systems, operator panels and touch screens, SCADA software MICRO PROGRAMMABLE LOGIC CONTROLLERS Mitsubishi Alpha 2 series ................................................................................................................1 - 2 NON-CONTACT SAFETY SWITCHES Series RC Si - M30 ................................................................................................................................2 - 6 Series RC Si - 56 ....................................................................................................................................2 - 6 Series HSSi4 .............................................................................................................................................2 - 7 Series BZ16 ..............................................................................................................................................2 - 7 Emergency stop trip-wire switch kits .....................................................................................2 - 8 Emergency stop trip-wire switches .........................................................................................2 - 9 Belt drift switches .............................................................................................................................2 - 10 Hitachi EH Micro series ....................................................................................................................1 - 6 MODULAR PROGRAMMABLE LOGIC CONTROLLERS Hitachi EH-150 series......................................................................................................................1 - 10 Micro and modular PLC accessory selection guide ...................................................1 - 15 FIELDBUS I/O SYSTEMS FOR INDUSTRIAL AUTOMATION APPLICATIONS Overview ................................................................................................................................................1 - 16 750 Series ..............................................................................................................................................1 - 21 857 Series JUMPFLEX Transducers ........................................................................................1 - 26 750 Series Intrinsically safe system........................................................................................1 - 28 750 Series PROFIsafe system .....................................................................................................1 - 29 LIMIT SWITCHES Light duty 6 A: ES/EM 95 series ...............................................................................................2 - 11 Medium duty 10 A: PS21 series ...............................................................................................2 - 11 Medium duty 10 A: PS31 series ...............................................................................................2 - 12 Medium Duty 6 A:ES/EM 41 series ........................................................................................2 - 12 EMERGENCY STOP TRIP-WIRE SWITCHES Type NTW cast aluminium .........................................................................................................2 - 13 Spare parts and accessories.......................................................................................................2 - 15 Installation instructions ................................................................................................................2 - 17 Heavy-duty limit switches: 77 HL and 77 TL series .....................................................2 - 19 750 Series Vibration monitoring .............................................................................................1 - 28 SAFETY CONTROLLERS 751 Series AS-i Fieldbus system ..............................................................................................1 - 30 Series NSC: Fail safe control unit ............................................................................................2 - 20 Programming and diagnostic software .............................................................................1 - 31 Series MF1: Standstill monitor ..................................................................................................2 - 20 750 Series Starter kits .....................................................................................................................1 - 34 Series SRM: Fail safe control unit ............................................................................................2 - 20 753 Series Quick connect............................................................................................................1 - 35 Limit switches - pull-wire (non safety) ................................................................................2 - 21 FIELDBUS I/O SYSTEMS FOR LONG DISTANCE, LIGHTING AND IRRIGATION CONTROL SYSTEMS Foot operated switches ...............................................................................................................2 - 22 Overview ................................................................................................................................................1 - 38 Ordering details .................................................................................................................................1 - 42 OPERATOR PANELS AND TOUCH SCREENS SC 207 ......................................................................................................................................................1 - 48 Pressure switches .............................................................................................................................2 - 23 3 Soft starters and drives Electronic soft starters product selection guide..............................................................3 - 2 Overview ................................................................................................................................................1 - 49 S+S Text based operator panels .......................................................................................................1 - 50 PCS - introduction, specifications and ordering details..............................................3 - 4 Graphics operator panels ............................................................................................................1 - 51 Graphics touch screens ................................................................................................................1 - 52 AUCOM Communications cables ..............................................................................................................1 - 54 CSX and CSXi - introduction, specifications and ordering details .......................3 - 7 VTWIN Configuration software ................................................................................................1 - 55 EMX3 - introduction, specifications and ordering details ......................................3 - 12 Dimensions and cut-outs............................................................................................................1 - 56 VARIABLE SPEED DRIVES VISUALISATION AND REPORTING SOFTWARE - ADROIT Product selection guide...............................................................................................................3 - 23 Overview - World class 32-bit SCADA/HMI software ................................................1 - 59 Santerno SINUS Nano range - introduction, standard specifications and ordering details.......................................................................................................................................................3 - 24 Ordering details .................................................................................................................................1 - 66 Switch mode power supplies...................................................................................................1 - 68 2 Safety SAFETY INTERLOCK SWITCHES SINUS Micro range - introduction, standard specifications and ordering details 3 - 25 SINUS Nano and Micro ranges - options...........................................................................3 - 26 SINUS Penta range - introduction, standard specifications and options .....3 - 27 SINUS Penta - range and selection (380 - 415 V) .........................................................3 - 32 Input and output choke - ordering details ......................................................................3 - 35 Semiconductor fuses and accessories - ordering details .......................................3 - 36 Series ST - 14: Light duty ................................................................................................................2 - 2 Brake resistor selection by duty cycle .................................................................................3 - 37 Series ES - 95: General purpose ..................................................................................................2 - 2 Brake resistors and accessories - ordering details .......................................................3 - 38 Series ST - 61: Heavy Duty .............................................................................................................2 - 3 Rating and selection chart..........................................................................................................3 - 40 Series ES - 95: General purpose rotary cam ........................................................................2 - 4 SINUS Penta - range and selection (660 - 690 V) .........................................................3 - 44 Series ES - 13SB: Light duty hinged .........................................................................................2 - 4 SINUS Penta - multi-pump application and....................................................................3 - 46 Series ES - 95: General purpose flap/hinge.........................................................................2 - 4 SINUS Penta - options ...................................................................................................................3 - 48 Series STM 295: Medium duty solenoid................................................................................2 - 5 SINUS Penta - specifications ......................................................................................................3 - 49 Series AZM 415: Heavy duty Solenoid ...................................................................................2 - 5 1 Automation products, PLCs, I/O systems, operator panels and touch screens, SCADA software Micro Programmable Logic Controllers Mitsubishi Alpha 2 series 1-2 Hitachi EH Micro series 1-6 Modular Programmable Logic Controllers Hitachi EH-150 series 1 - 10 Micro and modular PLC accessory selection guide 1 - 15 Fieldbus I/O systems for industrial automation applications Overview 1 - 16 750 Series 1 - 21 857 Series JUMPFLEX Transducers 1 - 26 750 Series Intrinsically safe system 1 - 28 750 Series PROFIsafe system 1 - 29 750 Series Vibration monitoring 1 - 30 751 Series AS-i Fieldbus system 1 - 31 Programming and diagnostic software 1 - 33 750 Series Starter kits 1 - 34 753 Series Quick connect 1 - 35 Fieldbus I/O systems for long distance, lighting and irrigation control systems Overview 1 - 38 Ordering details 1 - 42 Operator panels and touch screens SC 207 1 - 48 Overview 1 - 49 Text based operator panels 1 - 50 Graphics operator panels 1 - 51 Graphics touch screens 1 - 52 Communications cables 1 - 54 VTWIN Configuration software 1 - 55 Dimensions and cut-outs 1 - 56 Visualisation and reporting software - Adroit Overview - World class 32-bit SCADA/HMI software 1 - 59 Ordering details 1 - 66 Switch mode power supplies 1 - 68 1-1 FIELDBUS I/O SYSSTEMS TEMS MICCRO PLCS MODULAAR PLCS FIELLDBUSS I/O SYSTEMS 3XWPRUHFRQWUROLQ\RXUKDQGV L \RXU KD KDQGV QG Q GV OPEERATOR PANELS AND TOUCH H SCREENS SSWITCH W H MODE POWER SUUPPLIES Mitsubishi programmable logic controller Alpha 2 series 1 The simple, user friendly Mitsubishi _series has been designed for use around your home, office, factory...anywhere that requires flexible programmable control. Every Alpha allows your to analyse inputs and set outputs according to your program. The Alpha displays that status of your inputs and outputs on a LCD screen for quick verification. Features Q Q Q Q Q Q Q Q Q Q Compact and robust 100 V AC - 240 V AC or 24 V DC power supply 1500 bytes EEPROM memory standard Built-in Real Time Clock as standard Sourcing or sinking type DC inputs (on 24 V DC models only) 0-10 V analogue signal inputs (on 24 V DC models only) High current outputs On-device programming through keypad and LCD screen Windows based programming software, Visual Logic Easy access PC programming port Full-featured calendar and clock The Alpha family has a calendar and clock function with automatic summer/winter time switching. Each Alpha2 controller program can process up to 1,200 clock/calendar-activated on/off switching commands. Easier programming The graphical user interface of the AL-PCSWIN-E package makes programming the Alpha series very easy. On the left and right you have graphical representations of the inputs and outputs, with the pre-programmed function blocks between them (timers, counters, real-time clocks etc.). You just use the mouse to ‘draw’ graphical connections (circuits) between the inputs, function blocks and outputs to define the program logic. Using this simple approach you can create programs with up to 200 function blocks (Alpha 2), and each function block can be reused as many times as necessary within the same program. Program simulation This feature is particularly useful, enabling you to simulate your program without an Alpha controller connected to your PC. The AL-PCSWIN-E simulation module displays a realistic representation of the controller program. You can activate inputs by clicking with the mouse and the status of the function blocks and program execution are then displayed graphically on your screen. Monitoring functions The AL-PCSWIN-E “Monitor” function enables you to connect an Alpha controller to your computer and monitor actual program execution on your computer screen. In this mode the current status of the I/Os and function blocks are displayed on the screen during program execution. Process visualisation AL-PCSWIN-E also comes with a simple process visualisation system called ‘System Sketch’. It is displayed in a separate window into which you can copy and configure graphical elements from your program (inputs, outputs, function blocks etc.) or from another Windows application. Once you have set up the System Sketch window you can use it to perform a graphical simulation and monitoring of your program without using the programming interface. Among other things this can make setting up, installing and maintaining your application much simpler. Modem communications The Alpha is capable of connection to both GSM and land line modems. Through a GSM modem SMS text messages can be sent to multiple mobile phones from the Alpha whenever an event takes place that requires attention. SMS text messages can be sent to the Alpha from mobile phones to remotely control the outputs. Messages sent to the Alpha are accepted only from “known” mobile phone numbers and a return message is sent to confirm that the requested action has occurred. Dimensions (mm) 2- 4.2 Ø 2- 4.2 Ø 124.6 112.6 + - (A) (B) 1 2 3 DC INPUT 4 5 6 71.2 7 10 I/O 8 + POWER 24V DC 2 DC INPUT 3 4 5 6 + 90 + 82 US 82 R UL ESC 90 80M1 LISTED C IND. CONT.EQ. MITSUBISHI ELECTRIC CORPORATION MADE IN JAPAN 1-2 1 ESC - - OK OK AL2-14MR-D OUT1 (A) (B) POWER 24V DC 14/24 I/O All models are 52 mm deep. - RELAY OUTPUT AL2-10MR-D OUT2 OUT3 OUT4 RELAY OUTPUT OUT5 OUT6 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au OUT1 OUT2 OUT3 OUT4 GST not included Mitsubishi programmable logic controller Alpha 2 series The ALPHA 2 family Defining a new class of performance The new Alpha 2 family from Mitsubishi Electric defines a new class of performance for automation applications. With its outstanding capabilities the Alpha 2 family is set to dominate the class it has created. 1 The Alpha 2 will exceed your expectations in any task you set it and can process up to 200 function blocks in a single program, and every function (timers, counters, analogue signal processing, calendar, clock etc.) can be used as many times as you need in all your programs. Designed to suit all applications Q Public facilities - Airports, train stations, hospitals, road guidance Q Building automation - Lighting, HVAC, shutters/gates, security Q Commerce - Parking, stores, gas station, hotels golf courses Q Home automation - ON/OFF of electrical products, life support for aged, security Q Testing facilities - Testing and measuring equipment Q Exhibition stage effects - lighting, movement control Q Agriculture - Farms, green house, animal house, temperature watering, feeding control Q Hobby - Model making, gardening, weekend carpenter Q Education - Educational materials in schools Q Factory Automation - Automation equipment, facility retrofit, controls For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1-3 Mitsubishi programmable logic controller Alpha 2 series 1 The ALPHA family delivers unbeatable features and performance: • Operational in ambient conditions -25 °C to +55 °C • Alarm messages and process data can be displayed • Programming and variable adjustments can be made through the buttons and screen • Capable of being used as an AS-I bus slave • DC expansion input module can be used as a 1 KHz high speed counter • DNV, CE, UL and cUL Certifications • Graphical windows based software Digital Inputs Digital Base units Output 24 V DC 100 I/O counts Power Supply 240 V AC (sink/souce) Relays 100 - 240 V AC 6 10 24 V DC 4 6 100 - 240 V AC 8 14 24 V DC 24 V DC 8 AL-214-MRA 8 ) 2 AL-214-MRD 15 9 AL-224-MRA 8 ) Accessories Description 2 AL-224-MRD Cat. No. Price $ Programming/Comms cable, PLC to PC, or PLC to L/line Modem (9 pin D) AL-232-CAB USB to Serial converter (RS 232) USB-COM 3) Alpha DVD which includes AL-PCSWINE programming software, manuals, sample code, laboratory notes and quick start guides AL-DVD Transducer, PT100 RTD, 2 channel, 3-wire, -50 °C to +200 °C range AL2-2PT-ADP 4) Transducer, Thermocouple, 2 channel, K-Type, -50 °C to +450 °C range AL2-2TC-ADP 4) Memory Module, EEPROM to copy and transfer user memory AL2-EEPROM-2 5) GSM Modem with antenna, 12 - 24 V DC ALPHAGSMMODEM6)7) NEXTG Modem with antenna, 12 - 24 V DC ALPHANXGMODEM6)7) Modem cable, PLC to Modem, (9 pin D) AL2-GSM-CAB 6) External Power supply 24 V DC, 3.5 A power supply XCSL85C External Power supply 24 V DC, 5 A power supply XCSP120C Cat. No. AL2-14MRA + AL-232-CAB + USB-COM + AL-DVD AL2-14AC-KIT AL2-14MRD + AL-232-CAB + USB-COM + AL-DVD AL2-14DC-KIT AL2-24MRA + AL-232-CAB + USB-COM + AL-DVD AL2-24AC-KIT AL2-24MRD + AL-232-CAB + USB-COM + AL-DVD AL2-24DC-KIT AL Notes: ) ) 3 ) 4 ) 5 ) 6 ) 7 ) 1 2 1-4 6 Price $ AL-210-MRD 9 Starter kits Description Price Schedule ‘B3’ 4 Cat. No. AL-210-MRA 6 ) 1 6 100 - 240 V AC 15 24 Analogue Output 0-10 V DC Price $ Inputs can either be digital or analogue. The first 8 inputs can either be digital or analogue. Required for programming when no serial port is available on the personal computer. Temperature element is not included. Customer to supply. Cannot be used with old Alpha series PLCs. Not compatible with 10 I/O models. Requires an AL2-GSM-CAB, a DC power supply and a customer supplied SIM card. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Mitsubishi programmable logic controller Alpha 2 series 1 Description Cat. No. 4 Digital Input, 100-240 V AC AL2-4EX-A2 4 Digital Input, 24 V DC, NPN or PNP AL2-4EX 4 Digital Output, Relay, 2 A AL2-4EYR 4 Digital Output, Transistor PNP only 2 Analogue Output, 0-10 V DC, or 4-20 mA, Accuracy of +/- 1% full scale, resolution of 2.5 mV, or 8 mA, Load of 5K-1m, or up to 500 Ω AL2-4EYT Price $ AL2-2DA Visualisation with Graphical Operating Terminal (GOT) has never been easier Description Price Schedule ‘B3’ Cat. No. Price $ 4.5” STF 3 CLR high resolution 24 V DC + GT Designer3 software GT1030HBD2 ) HMI Programmable Cable GT01-C30R2-6P 2) USB to serial converter (RS-232) USB-COM Notes: 1 ) Additional GOT HMI are available. Please contact NHP. ) Cable suitable for GT1020 and GT1030 HMI. 1 2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1-5 Refer catalogue SI-E108U Micro programmable logic controllers EH Micro series 1 The EH-Micro series provides an economical, compact and yet powerful solution for your programmable logic control requirements. The base units of the EH-Micro series can either be used as a stand alone PLC, or most have the ability to connect to a much larger network. The base units can manage as few as 10 I/O, or as many as 320 I/O using the maximum of four expansion units. The range of features of the EH-Micro is extensive and the programming software is free for some of the smaller base units. (See below). Up to 32 individual EH-Micro base units can be networked to an Hitachi EH-150 PLC, or to a PC, or an IPC. The new EH-Micro web controller models, (Just like the EH-150 series) have the ability to act as a gateway from the Hitachi PLC ranges, through a LAN to a host PC, or IPC. Features Free software - ACTWIN can be downloaded from the NHP website. This version of the ACTWIN software allows full programming capabilities for the 10, 14 and 28 I/O base units only. It will permit all other base units to be programmed, but with the following limitations. • Program size max. 3 K steps • Ladder programming only • Analogue functions are not available • No expansion units are permitted To download the software go to: http://www.nhp.com.au/orc Register yourself with NHP and you will be presented with the member homepage. Go to – Product Info and Tools> Automation and Communication> PLC> ACTWIN Download the zip file, extract the contents to a folder, run “install.exe” and follow the instructions. Select the “Hitachi EH-Nano” driver option during the program installation. If you have any difficulty with this process then contact the Automation and Process department – 03 9420 4501 The programming software required for the 23 I/O EH-Micro base units and for all base units using any of the expansion units must be either ACTWINH, or the more economical ACTWINM1. ACTWINH can be also used for the larger Hitachi PLC series, while ACTWINM1 is only for the EH-Micro series. All three versions of the software are nearly identical and so there is no need to learn to how to use a new software package when moving to another Hitachi PLC Hardware series. All three versions of the software use ladder logic and are compliant with IEC61131-3. Q Base model options - 10/14/20/23/28/40/64 I/O Q PWM - 2 kHz total for 10/14/23/28 Transistor output models Q Expandable to 320 I/O with 4 x 64 I/O expansion units Q 24 V DC for ext. use, 14/20/23/28/40/64 I/O base models Q Digital input options - 24 V DC, both PNP and NPN (universal) Q Filtering delay - Adjustable 0 to 20 milliseconds - stop chatter Q Digital output options - relay, or 24 V DC NPN, PNP or SSR Q Removable terminals for easy installation and removal Q Analogue resolution - 12 bit Q Protective hinged terminal covers Q Analogue in options - 0-20 mA/4-20 mA/0-10 V/-10 V to +10 V Q Conformity to global standards - CE, UL, c-UL and C-Tick Q Analogue output options - 0-20 mA, 4-20 mA, 0-10 V Q RS 232 port, with selectable speed 4800 to 38400 bps. Q Power supply options 100-240 V AC, or 24 V DC Q RS 422/485 port for 23/28 base, optional 20/40/64 I/O base Q CPU - 32-bit RISC, 10 microseconds/instruction Q Real time clock - 20/23/28/40/64 I/O base models Q User Memory - 16 K steps 20/40/64 I/O, 3 K steps other Q LED indication of digital input and output status Q Data Memory - 32 K words 20/40/64 I/O, 4 K words other Q Relay contact life - 20 mill. mech, 200,000 elec @ 1.5 A Q Memory - Flash for User Memory, Battery for Data Memory Q Program Run/Stop switch 14/20/23/28/40/64 I/O base models Q Self diagnosis - LED indication memory, prog, battery low Q RTD modules - Pt100, 2&3 wire, -100 to +600°C range Q Programmable in Ladder, or IL - 101 instruction types Q External pots to adjust internal variables 14/23/28 I/O Q High speed counter - 1 phase, 100 kHz, 20/40/64 I/O bases Q Pulse Train - 65 kHz, 20/40/64 I/O transistor output models Q High speed counter - 2 phase, 60 kHz, 20/40/64 I/O bases Q Pulse Train - 5 kHz total, 16 bits for 10/14/23/28 models Q High speed counter - 1&2 phase, 10 kHz, 14/23/28 I/O base Q PWM - 65 kHz, 20/40/64 I/O transistor output models 1-6 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue SI-E108U Micro programmable logic controllers EH Micro series – Ordering details Approvals 10 I/O Base Units Description Cat. No. 6 DI, 24 V DC / 4 DO, 24 V DC PNP Transistor / 24 V DC power supply EH-D10DTP 6 DI, 24 V DC / 4 DO, 24 V DC NPN Transistor / 24 V DC power supply EH-D10DTN 6 DI, 24 V DC / 4 DO, Relay, 2 ampere / 24 V DC power supply EH-D10DR 8 DI, 24 V DC / 6 DO, 24 V DC PNP Transistor / 24 V DC power supply EH-D14DTP 8 DI, 24 V DC / 6 DO, 24 V DC NPN Transistor / 24 V DC power supply EH-D14DTN 8 DI, 24 V DC / 6 DO, 24 V DC PNP Transistor, Short Circuit Protected / EH-D14DTPS Price $ 1 24 V DC power supply 14 I/O 8 DI, 24 V DC / 6 DO, Relay, 2 ampere / 24 V DC power supply EH-D14DR 8 DI, 24 V DC / 6 DO, Relay, 2 ampere / 110-240 V AC power supply EH-A14DR 8 DI, 110 V AC ONLY / 6 DO, 110-240 V AC SSR, 0.5 ampere / EH-A14AS 110-240 V AC power supply 12 DI, 24 V DC / 8 DO, 24 V DC NPN Transistor / 24 V DC power supply EH-D20DTN 12 DI, 24 V DC / 8 DO, 24 V DC PNP Transistor, Short Circuit Protected / EH-D20DTPS 24 V DC power supply 20 I/O 12 DI, 24 V DC / 8 DO, Relay, 2 ampere / 24 V DC power supply EH-D20DR 12 DI, 24 V DC / 8 DO, Relay, 2 ampere / 110-240 V AC power supply EH-A20DR 13 DI, 24 V DC, 2 AI, 0-10 V DC, or 0-20 mA / 9 DO, Relay, 2 ampere, 1 DO, EH-D23DRP 24 V DC PNP Transistor, 1 AO, 0-10 V DC, or 0-20 mA / 24 V DC power supply 13 DI, 24 V DC, 2 AI, 0-10 V DC, or 0-20 mA / 9 DO, Relay, 2 ampere, 1 DO, 24 EH-A23DRP V DC PNP Transistor, 1 AO, 0-10 V DC, or 0-20 mA / 110-240 V AC power supply 23 I/O 16 DI, 24 V DC / 12 DO, 24 V DC PNP Transistor / 24 V DC power supply EH-D28DTP 16 DI, 24 V DC / 12 DO, 24 V DC NPN Transistor / 24 V DC power supply EH-D28DTN 16 DI, 24 V DC / 12 DO, 24 V DC PNP Transistor, short circuit protection / EH-D28DTPS 24 V DC power supply 16 DI, 24 V DC / 11 DO, Relay, 2 ampere, 1 DO 24 V DC PNP Transistor / EH-D28DRP 24 V DC PS 28 I/O 16 DI, 24 V DC / 11 DO, Relay, 2 ampere, 1 DO 24 V DC PNP Transistor / AC PS EH-A28DRP 16 DI, 24 V DC / 12 DO, Relay, 2 ampere / 24 V DC power supply EH-D28DR 16 DI, 24 V DC / 12 DO, Relay, 2 ampere / 110-240 V AC power supply EH-A28DR 16 DI, 110 V AC ONLY / 12 DO, 110-240 V AC SSR, 0.5 ampere / EH-A28AS 110-240 V AC power supply 24 DI, 24 V DC / 16 DO, 24 V DC PNP Transistor, short circuit protection / EH-D40DTPS 24 V DC power supply 40 I/O 24 DI, 24 V DC / 16 DO, 24 V DC NPN Transistor / 24 V DC power supply EH-D40DTN 24 DI, 24 V DC / 16 DO, Relay, 2 ampere / 24 V DC power supply EH-D40DR 24 DI, 24 V DC / 16 DO, Relay, 2 ampere / 110-240 V AC power supply EH-A40DR 40 DI, 24 V DC / 24 DO, 24 V DC PNP Transistor, short circuit protection / EH-D64DTPS 24 V DC power supply 40 DI, 24 V DC / 24 DO, 24 V DC NPN Transistor / 24 V DC power supply EH-D64DT 40 DI, 24 V DC / 24 DO, Relay, 2 ampere / 24 V DC power supply EH-D64DR 40 DI, 24 V DC / 24 DO, Relay, 2 ampere / 110-240 V AC power supply EH-A64DR 64 I/O Price Schedule ‘B3’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1-7 Refer catalogue SI-E108U Micro programmable logic controllers EH Micro series – Ordering details Expansion Units - Digital 1 Price Schedule ‘B3’ 1-8 Description 8 DI, 24 V DC / 24 V DC power supply 8 DO, 2 ampere / 24 V DC power supply 8 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply 8 DO, 24 V DC NPN Transistor / 24 V DC power supply 4 DI, 24 V DC / 4 DO, Relay, 2 ampere / 24 V DC power supply 4 DI, 24 V DC / 4 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply 4 DI, 24 V DC / 4 DO, 24 V DC NPN Transistor / 24 V DC power supply 8 DI / 6 DO, 24 V DC PNP Transistor / 24 V DC power supply 8 DI / 6 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply 8 DI / 6 DO, 24 V DC NPN Transistor / 24 V DC power supply 8 DI, DC / 6 DO, Relay, 2 ampere / 24 V DC power supply 8 DI, DC / 6 DO, Relay, 2 ampere / 110-240 V AC power supply 16 DI, 24 V DC / 24 V DC power supply 16 DO, Relay, 2 ampere / 24 V DC power supply 16 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply 16 DO, 24 V DC NPN Transistor / 24 V DC power supply 16 DI / 12 DO, 24 V DC PNP Transistor / 24 V DC power supply 16 DI / 12 DO, 24 V DC PNP Transistor, Short Circuit Protected / 24 V DC power supply 16 DI / 12 DO, 24 V DC NPN Transistor / 24 V DC power supply 16 DI / 12 DO, Relay, 2 ampere / 24 V DC power supply 16 DI / 12 DO, Relay, 2 ampere / 110-240 V AC power supply 40 DI, 24 V DC / 24 DO, 24 V DC NPN Transistor / 24 V DC power supply 40 DI, 24 V DC / 24 DO, 24 V DC NPN Transistor / 24 V DC power supply 40 DI, 24 V DC / 24 DO, relay 2 ampere / 24 V DC power supply 40 DI, 24 v DC / 24 DO, relay 2 ampere / 100 - 240 V AC power supply Expansion Units - Analogue 4 AI, 0-10 V DC or -10 to +10 V DC or 0-20 mA or 4-20 mA / 2 AO, 0-10 V DC or 0-20 mA or 4-20 mA / 110-240 V AC power supply Cat. No. EH-D8ED 4 AI, 0-10 V DC or -10 to +10 V DC or 0-20 mA or 4-20 mA / 2 AO, 0-10 V DC or 0-20 mA or 4-20 mA / 24 V DC power supply 4 RTD, PT100, 2 or 3 wire / 24 V DC power supply 4 RTD, PT100, 2 or 3 wire / 110-240 V AC power supply 4 RTD, PT100, 2 or 3 wire / 2 AO, 0-10 V DC or 0-20 mA or 4-20 mA / 24 V DC power supply 4 RTD, PT100, 2 or 3 wire / 2 AO, 0-10 V DC or 0-20 mA or 4-20 mA / 110-240 V AC power supply 2 AI, 0-10 V DC with RS232C port for 20, 40 and 64 I/O base units 2 AI, 0-10 V DC with RS485 port for 20, 40 and 64 I/O base units Expansion Cables Expansion cable, 100 cm long (included for free with all types of expansion modules) Expansion cable, 500 cm long (vertical arrangement) Expansion cable, 1000 cm long (remote arrangement) EH-A6EAN Price $ EH-D8ER EH-D8ETPS EH-D8ETN EH-D8EDR EH-D8EDTPS EH-D8EDTN EH-D14EDTP EH-D14EDTPS EH-D14EDTN EH-D14EDR EH-A14EDR EH-D16ED EH-D16ER EH-D16ETPS EH-D16ETN EH-D28EDTP EH-D28EDTPS EH-D28EDTN EH-D28EDR EH-A28EDR EH-D64EDT EH-D64EDTPS EH-D64EDR EH-A64EDR EH-D6EAN EH-D4ERTD EH-A4ERTD EH-D6ERTD EH-A6ERTD EH-OB232 EH-OB485 EH-MCB01 EH-MCB05 EH-MCB10 Approvals For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue SI-E108U Micro programmable logic controllers EH Micro series – Ordering details Approvals Programming Software Description Cat. No. Programming software for EH Micro base units, 10, 14, and 28 I/O Programming software for EH Micro Programming software for EH Micro/EH150/H200/H250/H252 Programming cable, PLC to PC, (9 pin D), 200 cm Price $ ACTWINCD ) 1 1 ACTWINM1 1) ACTWINH 1) CBL-1509 Accessories EH-OB232 Description Cat. No. RS232C port with 2 AI, 0-10 V DC for 20, 40 and 64 I/O base units Plug on module EH-OB232 RS485 port with 2 AI, 0-10 V DC for 20, 40 and 64 I/O base units Plug on module EH-OB485 Memory unit for backup of a user program - Plug on module EH-OBMEM USB to serial converter (RS232C) - Plug on Module EH-OBUSB USB to serial converter (RS232) Plug in Cable USB-COM Battery Standard for 23 or 28 I/O base units EH-MBAT Battery Long for 23 or 28 I/O base units EH-MBATLC Battery Long for 20, 23, 28, 40 and 64 I/O base units EH-MBATL External Power supply 24 V DC, 3.5 Ampere power supply XCSP85C External Power supply 24 V DC, 5 Ampere power supply XCSP120C Price $ EH-OBUSB Dimensions (mm) 85 95 185 195 Price Schedule ‘B3’ Notes: ) 1 90 Elevation 14/20/23/28/40/64 I/O 80 90 90 80 64 64-point I/O base,type 64 I/O expansions 140 150 140 150 4.8 23/28 I/O basestype 23/28-point 4.8 80 47 4.8 65 75 20/40 I/O bases type 20/40-point 80 1414-point I/O base, 8/168/16-point expansionsexpansion unit type, 80 70 Elevation 10 I/O 90 10 10-point I/O base type 7676 8.4 8.4 Read about software on page 1 - 6. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1-9 Refer catalogue SI-E103Y Modular programmable logic controllers EH-150 series 1 Approvals Quality Control Flexible networking possibilities Programming Terminal Adroit SCADA Ethernet IEEE802.3 Web Controller EH-150 EH-150 EH-Micro 20/23/28/40/64 I/O EH-150 H252 RS-422 up to 32 units connectable Optical Link H-302~H-4010 ESA HMI 1 - 10 EH-150 Coaxial Link EH-150 EH-150 Profibus® Slave Third Party Profibus® Slaves H252 EH-150 DeviceNet™ Slave For further information please contact Sales 1300 NHP NHP or visit nhp.com.au H-302~H-4010 Third Party DeviceNet™ Slaves GST not included Refer catalogue SI-E103Y Modular programmable logic controllers EH-150 series Introduction Approvals The EH-150 series of PLCs incorporates the most advanced technologies in its compact body, such as a 32 bit RISC chip microcomputer for high speed arithmetic operations and a large flash memory. A big range of modular hardware options allows systems to be tailored to the requirements of each application, while spending a minimum on capital outlay and permitting future upgrades and expansions. The EH-150 series can easily network with other PLCs in the Hitachi range and it supports several common fieldbus systems, such as Ethernet, Profibus, Modbus and DeviceNet™ allowing communication with third party devices. 1 Ordering details – EH-150 series CPUs Description Up to 512 I/O, Up to an 8 slot rack, No expansion racks possible, 4 K flash, 2 Ports @ 19.2 kbps Up to 1,024 I/O, Up to an 8 slot rack, Up to 1 expansion rack of up to 8 slots, 8 K Flash, 2 Ports @ 38.4 kbps, Real Time Clock, Modem Control Up to 1,024 I/O, Up to an 8 slot rack, Up to 1 expansion rack of up to 8 slots, 16 K Flash, 2 Ports @ 38.4 kbps, Real Time Clock, Modem Control, Additional Control Functions Up to 2,112 I/O, Up to an 11 slot rack, Up to 2 expansion racks of up to 11 slots, 16 K Flash, 2 Ports @ 38.4 kbps, Real Time Clock, Modem Control, Additional Control Functions Up to 3,520 I/O, Up to an 11 slot rack, Up to 4 expansion racks of up to 11 slots, 48 K Flash, 2 Ports @ 38.4 kbps, Real Time Clock, Modem Control, Additional Control Functions Base Rack Power Supply Modules Input from 85 to 264 V AC / Output, 3.8 ampere @ 5 V DC and 0.4 ampere @ 24 V DC Input 21.6 to 26.4 V DC / Output, 3.8 ampere @ 5 V DC Base Racks Space for Power supply and CPU and 3 slots for I/O modules Space for Power supply and CPU and 5 slots for I/O modules Space for Power supply and CPU and 8 slots for I/O modules Space for Power supply and CPU and 11 slots for I/O modules, Requires EH-CPU516 and above Memory Modules Stores up to 48 K steps of user program for EH-CPU316 and above Stores up to 16 K steps of user program and stores 384 K words of memory data for EH-CPU316 and above I/O Controller Required for each expansion rack if not using Profibus, or Devicenet slaves Linking cable between racks and the EH-IOCH I/O controller, 1 meter long Communication Modules Devicenet master, 256 word input, 256 word output. Requires EH-CPU316 and above. Up to 2 masters can be installed per CPU in LINK mode and 4 in REMOTE mode. Up to 63 slaves can be controlled by each master Devicenet slave (check compatibility of I/O) Profibus master, 256 word input, 256 word output. Requires EH-CPU316 and above. Up to 2 masters can be installed per CPU. Up to 124 slaves can be controlled by each master Profibus slave (check compatibility of I/O) Ethernet, IEEE802.3 standard, 10 BASE-T, TCP or UDP. Requires EH-CPU316, or above Serial communications, Modbus RTU, Modbus ASCII, RS232C port and RS232C/422/485 port. Requires EH-CPU516 and above CPU Link Modules – Requires EH-CPU 316 and above Coaxial Link, 1.0 Mbps, Up to 500 meters between stations. Up to 64 stations Optical Link, 1.0 Mbps, Up to 1,000 meters between stations. Up to 64 stations EH-CPU104 EH-CPU548 EH-RMD EH-I0CD Cat. No. Price $ EH-CPU104 EH-CPU208 EH-CPU316 EH-CPU516 EH-CPU548 EH-PSA EH-PSD EH-BS3 EH-BS5 EH-BS8 EH-BS11 EH-MEMP EH-MEMD EH-IOCH EH-CB10 EH-RMD EH-IOCD EH-RMP EH-IOCP EH-ETH2 EH-SIO EH-LINK EH-OLINK Price Schedule ‘A4’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 11 Refer catalogue SI-E103Y Modular programmable logic controllers EH-150 series (Cont’d) Ordering details DC Input Modules Description 1 EH-YR16 EH-XD16 Approvals Cat. No. 16 DI, 24 V DC, Removable screw terminal block EH-XD16 32 DI, 24 V DC, Plug connector EH-XD32 1) 64 DI, 24 V DC, Plug connector EH-XD64 1) 8 DI, 24 V DC, Removable screw terminal block EH-XD8 16 DI, 24 V DC, 16 millisecond filter, Removable screw terminal block EH-XDL16 32 DI, 24 V DC, 16 millisecond filter, Plug connector EH-XDL32 1) 32 DI, 24 V DC, Euro cage clamp connector EH-XD32E 32 DI, 24 V DC, 16 millisecond filter, Euro cage clamp connector High Density Input Interface Board and Cable EH-XDL32E 32 Input terminal interface board EHTRM32 Cable for 32/64-point Input modules (Connectors at both ends) AC Input Module EHCBLIN32 16 DI, 100 to 120 V AC, Removable screw terminal block EH-XA16 16 DI, 200 to 240 V AC, Removable screw terminal block DC Output Module EH-XAH16 16 DO, 12 to 24 V DC, PNP Transistor, Removable screw terminal block EH-YTP16 32 DO, 12 to 24 V DC, PNP Transistor, Plug connector EH-YTP32 2) 64 DO, 12 to 24 V DC, PNP Transistor, Plug connector EH-YTP64 2) 16 DO, 12 to 24 V DC, NPN Transistor, Removable screw terminal block EH-YT16 32 DO, 12 to 24 V DC, NPN Transistor, Plug connector EH-YT32 2) 64 DO, 12 to 24 V DC, NPN Transistor, Plug connector EH-YT64 2) 8 DO, 12 to 24 V DC, NPN Transistor, Removable screw terminal block EH-YT8 8 DO, 12 to 24 V DC, PNP Transistor, Removable screw terminal block EH-YTP8 16 DO, 12 to 24 V DC, PNP Transistor with Short Circuit Protection, Removable screw terminal block EH-YTP16S 32 DO, 12 to 24 V DC, NPN Transistor, Euro cage clamp connector EH-YT32E 32 DO, 12 to 24 V DC, PNP Transistor, Euro cage clamp connector EH-YTP32E Price $ High Density Output Interface Board and Cable EH-XD32 16 Output relay interface board EHRLY16 Cable for 32 and 64-point Output modules (Connectors at both ends)(PNP Only) EHCBLOUT32PNP Cable for 32 and 64-point Output modules (Connectors at both ends)(NPN Only) EHCBLOUT32NPN Plug in relay for EHRLY16 40.51-24 VDC AC Output Module EH-XD64 16 DO, 100/240 V AC, Triac, Removable screw connector EH-YS16 4 DO, 100/240 V AC, Triac, Removable screw connector Relay Output Module EH-YS4 16 DO, Relay, 2 ampere, Removable screw terminals EH-YR16 8 DO, Relay, 2 ampere, Isolated commons, Removable screw terminals EH-YR8B 12 DO, Relay, 2 ampere, Removable screw terminals High Function Module EH-YR12 2 High Speed Counter Inputs, 32 bit, Up to 100 KHz, 1, or 2 phase, 2-point open collector output, Plug connector EH-CU Cable for EH-CU counter module. 30 to 34 socket. Interface board for EH-CBLCU counter cable. Cage clamp connectors 34 pin/point 2 High Speed Counter Inputs, 32 bit, Up to 100 KHz, 1, or 2 phase, 2-point open collector output, Euro cage clamp connector EH-CBLCU Notes: Price Schedule ‘A4’ 1 - 12 289-506 EH-CUE ) Requires 1 (2) High density input interface board(s) and 1 (2) cable(s) for 32 (64) input module. ) Requires 2 (4) High density output interface boards and 1 (2) cable(s) and 32 (64) relays for 32 (64) output module. 1 2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue SI-E103Y Modular programmable logic controllers EH-150 series (Cont’d) Ordering details Approvals Analogue Input Module EH-TC8 Description Cat. No. 8 AI, 0-10 V DC, 12 bit resolution, Removable screw terminals EH-AX8V 8 AI, -10 to +10 V DC, 12 bit resolution, Removable screw terminals EH-AX8H 8 AI, 4-20 mA, 12 bit resolution, Removable screw terminals EH-AX8I 4 AI, PT100, or PT1000 RTD, 15 bit signed resolution, Removable screw terminals EH-PT4 8 AI, Thermocouple types K,E,J,T,B,R,S,N selectable, 15 bit resolution EH-TC8 4 AI, 4-20 mA and 4 AI, 0-10 V DC, 12 bit resolution, Removable screw terminals EH-AX44 8 AI, 0-22 mA, 12 bit resolution, Removable screw terminals EH-AX8IO 8 AI, 0-22 mA, 4-22 mA, 0-10 V DC, selectable, 14 bit resolution, Removable screw terminals EH-AXH8M Price $ 1 Analogue Output Module EH-YTP64 4 AO, 0-10 V DC, 12 bit resolution, Removable screw terminals EH-AY4V 4 AI, -10 to +10 V DC, 12 bit resolution, Removable screw terminals EH-AY4H 4 AO, 4-20 mA, 12 bit resolution, Removable screw terminals EH-AY4I 2 AO, 4-20 mA and 2 AO, 0-10 V DC, 12 bit resolution, Removable screw terminals EH-AY22 2 AI, -10 to +10 V DC, 12 bit resolution, Removable screw terminals EH-AY2H 8 AO, 0-22 mA, 4-22 mA, 0-10 V DC, selectable, 14 bit resolution, Removable screw terminals EH-AYH8M Programming Items Programming Software, (IEC 61131-3 compliant), site license ACTWINH PC-PLC programming cable, 2 meters long, 9 pin female to RJ45 CBL-1509 USB to serial converter, for when your laptop doesn't have a serial port USB-COM SYCON Profibus configuration software SYCON Miscellaneous Lithium Battery to backup data memory during power outage LIBAT-H Cover for unused slots in racks EH-DUM DC power supplies EH-POS External Power supply 24 V DC, 3.5 Ampere power supply XCSP85C 1) External Power supply 24 V DC, 5 Ampere power supply XCSP120C 1) Positional control modules Single axis, Plug connector EH-POS Four axis, Plug connector EH-POS4 Dimensions (mm) Base EH-BS8 EH-BS5 EH-BS3 Number of I/O modules 11 8 5 3 L1 447 357 267 207 L2 462.5 372.5 282.5 222.5 EH-CU Price Schedule ‘A4’ EH-BS11 Notes: ) XCSF85C and XCSF120C power supplies are on Price Schedule ‘A2’. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 13 IEC 61131-3 PROGRAMMING SOFTWARE 'PS)JUBDIJ1-$T FREE Developm en Software t r 4VQQPSUT *&$MBOHVBHFT-BEEFS BOE4'$ )JUBDIJTQFDJGJDDPEF FYJTUJOH"$5TJQ%04 CBTFE QSPHSBNT r 4FMGQBDFEIBOETPOUVUPSJBMT JODMVEFE r #VJMUJOQSPHSBNTJNVMBUPSGPS QSPHSBNUFTUJOHEFCVHHJOH r 0OMJOFDPOUFYUTFOTJUJWFIFMQ ActWin licensed packages ActWin-M14VQQPSUTFOUJSF)JUBDIJ&).JDSP TFSJFT&)&) -BEEFSJOCPUI*&$BOE )JUBDIJ)TQFDJGJDGPSNBUT Minimum system requirements 64 MB RAM, 25 MB free HDD space, CD-ROM drive and Windows® 95/98 XP or NT4.0/2000 ActWin-H4VQQPSUTFOUJSF)JUBDIJ)TFSJFT &)&))#PBSE&)) ) -BEEFSJOCPUI*&$BOE)JUBDIJ )TQFDJGJDGPSNBUT "TLZPVS/)1SFQSFTFOUBUJWFGPSZPVSGSFF DPQZPGUIF"DU8JOQSPHSBNNJOHTPGUXBSF$% PSWJTJUOIQDPNBV For licensing, please contact your nearest NHP representative. 5IJTGSFFVOMJDFOTFEDPQZBMMPXTZPV'6-- MBEEFSQSPHSBNNJOHDBQBCJMJUJFTGPSUIF&) .JDSPTFSJFT&)&)BOE&)CBTF NPEFMTPOMZ QMVTUIFBCJMJUZUPVQMPBEBOE EPXOMPBESVOHTPGDPEFBQQSPYTUFQT UPBMMPUIFS)JUBDIJ)TFSJFT1-$T r 0OQBDLBHFGPSBMM)JUBDIJ1-$T 4BMFT/)1/)1OIQDPNBV 4BMFT/)1/)1OIQO[DPN /"$51-"%7 AUTOMATION SYSTEMS Micro and modular PLC accessory selection guide PLC type Mitsubishi EH-150 / H200/250/252 H300/700/2000 Alpha 2 EH MICRO H Board 302/702/1002/2002, Software AL-PCSWIN-E ACTWINH ACTWINH ACTWINH ACT-MINI PC to PLC AL-232CAB CBL-1509 CBL-90H CBL-90H EM3 - CBLEM3 EC / EM series cables Programmers EC - CBLEC Via front panel EH150 PGMCHH PGMCHH PGMJ -PGMCHH PGMGPH PGMGPH PGMJR2 PGCB-02H PGCB-02H CNPG15 1 -PGMGPH Programmer to EH150 N/A PLC cables - PGCB02H + RS05 Programmer to N/A N/A N/A N/A CBL-PGMJR N/A EH Micro CNM-01 1st rack (W/CPU) EM series expansion rack -EHMCB10 CNM-06 CBL-05H -CNM01 cables -EHMCB05 CNM-10 CBL-10H -CNM06 -EHMCB01 CNM-S10 PC cables Base/main to EH150 Rack to rack -CNM10 (Expansions) -CNMS10 -EHCB10 CBE-05H CBE-10H Interface board cables EHRLY16 N/A EHTRM32 HTRMBRD32 Batteries N/A EHCBLOUT32 CBLHOUT32 EHCBLIN32 – – CBM-02 EH 150-LIBATH LIBAT-H N/A N/A LIBAT-H N/A EH Micro-EHMBAT Cable guide EH MICRO SERIES EHCBLIN32 Mitsubishi Alpha 2 CBL-1509 AL-232CAB CBL-1509 AL-232CAB Mitsubishi Alpha (Discontinued) EHCBLOUT32 EH-150 SERIES EHRLY16 CBL-90H CBL-EM3 EHTRM32 EHRLY16 H200/250/252 SERIES (Discontinued) HTRMBRD32 CBL-EC CBM-02 CBLHOUT32 CBL-PGMJR EM 3 SERIES (Discontinued) EC SERIES (Discontinued) CNPG-15 EM SERIES (Discontinued) PGMJ-R2 (Discontinued) CABLE ONBOARD PROGRAMMER For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 15 Refer catalogue WFC2 WAGO I/O-System Fieldbus independent BUS terminal block Quick adaption to standard fieldbus systems 1 Using the WAGO I/O-SYSTEM it is now possible: Q To proceed with external wiring of the I/O modules without knowledge of the fieldbus system to be used Q simple snap-fit mounting of the respective fieldbus coupler to the wired modules when fieldbus system is known This gives inventory reduction and greater availability of modules for many different fieldbus systems, by adaption of all modules with a single bus coupler chosen for that system. DeviceNet A huge range of fieldbus connection options are available Profibus Ethernet Modbus Optimum design of a Fieldbus node The following requirements must be met in order to design an economic fieldbus node: Q Q Q Q Q Q Q Q 1 - 16 best possible modularity – 1, 2, 4 or 8 channel for standard I/Os – single channel for special functions combination of digital and analogue I/Os including various voltage, power and instrumentation signal requirements within a node sensors and actuators may be wired independently of the fieldbus fast coupling to the chosen fieldbus quick and clear marking facility easy handling with few additional accessories fast and easy wiring with high operational reliability RS 232/RS 485 communication modules, user configurable and easy to use For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue WFC2 WAGO I/O-System Fieldbus independent BUS terminal block Combination of different functions Over 350 module types in the range 1 Digital inputs 1) Digital outputs 2) Analogue inputs 3) Wide choice of Fieldbus couplers with integrated supply terminal block for external 24 V DC Profibus Interbus CAN Open DeviceNet Modbus LON Ethernet Notes: Analogue outputs 4) Special functions The combination of digital and analogue I/Os with different potentials, powers and measuring signals allows the realisation of user specific fieldbus nodes. ) ) 3 ) 4 ) 1 2 Supply terminal block for external 230 V AC. Supply terminal block for external 24 V DC (electrical isolation). Supply terminal block for external modification of reference potential. Supply terminal block for external 5 V DC. Flexibility Approvals Each node of the WAGO® I/O System can easily be assembled to match your existing fieldbus and I/O needs, or adapted to meet your changing requirements. One, two, four and eight channel I/O modules allow you to purchase the minimum amount of I/O that you need for your application. Nodes can each accommodate up to 64 multi-channel modules. The range of modules includes over 350 types to suit your diverse I/O needs. There are digital I/O, analogue I/O, and 16 specialty modules in the range with new modules being frequently developed. The specialty modules include counters, encoder inputs, RS 232 and RS 485 serial comms, AS-i, DALI/DSI, MP-bus, SSI and TTY 20 mA loop. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 17 Refer catalogue WFC2 WAGO I/O-System – 750 Series The BUS terminal block The universal basic module 1 Assembly Power jumper contacts on the field side Slim design modules for assembly onto DIN rail... Safe, automatic connection by tinned, self-cleaning slide contact, ground (earth) makes first and breaks last W x H 1) x D (mm) 12 x 64 x 100 Note: ) From upper edge of carrier rail. 1 H ...secure connection with dovetails Exchange within the assembly D W Quick exchange of a bus terminal block Data contacts ...within the assembly – without tools 1 - 18 Safe, automatic connection by gold-plated, self-cleaning, slide contacts. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue WFC2 WAGO I/O-System – 750 Series The BUS terminal block The universal basic module Colour coded for identification/handling 1 Marking of clamping units by coloured miniature WSB markers Yellow Red Green Blue Clear - digital inputs digital outputs analogue inputs analogue outputs supply and special function terminal block Different functions marked by transparent coloured group marker carriers Moulded marking of clamping units Group marking carrier (can be withdrawn and replaced) with large area for self marking CAGE-CLAMP connection Status indication Testing Vibration proof, fast and maintenance-free wiring of 0.08 mm2-2.5 mm2/AWG 28-14 Diagnosis and status indication by LED for safe start-up and system control Signal tracing with wired conductors Fuse holder Function at locked position 1: Power output to I/O group is off Function at locked position 2: Easy fuse replacement via hinged cover For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 19 WAGO I/O-System Fieldbus independent BUS terminal block Automation in industry 1 Complex production equipment such as that used in automated manufacturing industries use large numbers of sensors and actuators. Use of a fieldbus system and distributed control can considerably reduce costs. Fieldbus nodes (the fieldbus connection + I/O points) are of special importance in this context. If these are properly designed much of the cost can be minimised. Typical node featuring optional Quick Connect I/O modules A WAGO I/O node may be physically divided into several parts and the Data bus extended for up to 5 metres using Extension modules and standard RJ45 connectors and cables. A free software tool and a 750920 programming cable is also required. Extended WAGO I/O node example 1 - 20 Internal Data Bus Extension Coupler Modules For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included WAGO I/O System – 750 Series Fieldbus couplers / Economy fieldbus couplers (smaller process image) - Stocked Description Profibus DP/V1, 12 MBaud DeviceNet, 125-500 Kbaud Ethernet TCP/IP 10 Mbit/s Ethernet TCP/IP 10/100 Mbit/s Modbus RS 485, 150-19200 baud Profibus DP, 12 MBaud (economy) DeviceNet, 125-500 Kbaud (economy) Cat. No. 750-333 750-306 750-342 750-341 750-312 750-343 750-346 Price $ 1 Programmable Fieldbus controller - Stocked 750-333 Profibus Profibus DP/V1, 12 MBaud ProfiNet TCP/IP, 100 Mbit/s Ethernet TCP/IP 10 Mbit/s Ethernet TCP/IP 10/100 Mbit/s Ethernet TCP/IP 10/100 Mbit/s, with RS232 serial port 750-833 750-840 750-842 750-841 750-873 Fieldbus couplers / Economy fieldbus couplers (smaller process image) - Indent 1) 750-306 DeviceNet 750-343 Eco-Coupler 750-833 Programmable Price Schedule ‘A4’ Profibus DP, 1.5 MBaud, fibre optic ProfiNet TCP/IP, 100 Mbit/s ProfiNet TCP/IP, 100 Mbit/s, 2 port Ethernet, Powerlink, 10/100 Mbit/s, V2, ARP, HTTP, DNS,SNTP, FTP Modbus RS 232, 150-19200 baud Modbus RS 485, 1.2-115.2 Kbaud Modbus RS 232, 1.2-115.2 Kbaud CANopen, 10 Kbaud - 1 Mbaud, MCS CANopen, 10 Kbaud - 1 Mbaud, D-Sub LON, FTT Peer to Peer, FTT Interbus, 500 KBaud Interbus, fibre optic CAL, 10 Kbaud - 1 Mbaud Firewire, 100 MBaud, 200 MBaud, 400 MBaud CC-Link, 156 KBaud, 10 Mbaud II/O-Lightbus, 2.5 MBaud II/O-Lightbus, 2.5 MBaud, digital signals only SDS Sercoss III Interbus, 500 KBaud (economy) Interbus, 2 MBaud (economy) CANopen, 10 Kbaud - 1 Mbaud, MCS (economy) CANopen, 10 Kbaud - 1 Mbaud, D-Sub (economy) Programmable Fieldbus controller - Indent 1) DeviceNet, 125-500 Kbaud Ethernet TCP/IP 10/100 Mbit/s, 2 port Ethernet TCP/IP 10/100 Mbit/s, 2 port, integrated switch LON, FTT Modbus RS 485, 150-19200 baud Modbus RS 232, 150-19200 baud Modbus RS 485, 1.2-115.2 Kbaud Modbus RS 232, 1.2-115.2 Kbaud Interbus, 500 KBaud CANopen, 10 Kbaud - 1 Mbaud, MCS CANopen, 10 Kbaud - 1 Mbaud, D-Sub BACnet/IP KNXnet/IP Linux, 32-bit ARM CPU, 44 MHz, 16 MB RAM, 2.5 MB for JFFS2, BSP with 2.6 kernel, CGI Notes: 750-331 750-340 750-370 750-350 750-314 750-315 750-316 750-337 750-338 750-319 750-319/004-000 750-304 750-334 750-305 750-339 750-310 750-300 750-320 750-313 750-351 750-344 750-345 750-347 750-348 750-806 750-871 750-881 750-819 750-812 750-814 750-815 750-816 750-804 750-837 750-838 750-830 750-849 750-860 ) WAGO indent items have a typical delivery time of 2-3 weeks. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 21 Refer catalogue WFC2 WAGO I/O System – 750 Series Digital Input modules / Digital Output modules - Stocked 1 750-400 750-430 750-424 750-530 Description 4 DI, DC 5 V, 0.2 ms, 2 to 3 connection, PNP 2 DI, DC 24 V, 3.0 ms, 2 to 4 connection, PNP 2 DI, DC 24 V, 0.2 ms, 2 to 4 connection, PNP 4 DI, DC 24 V, 3.0 ms, 2 to 3 connection, PNP 4 DI, DC 24 V, 3.0 ms, 2 connection, PNP 4 DI, DC 24 V, 0.2 ms, 2 to 3 connection, PNP 4 DI, DC 24 V, 3.0 ms, 2 to 3 connection, NPN 8 DI, DC 24 V, 3.0 ms, 1 connection, PNP 8 DI, DC 24 V, 0.2 ms, 1 connection, PNP 4 DI, AC/DC 24 V, 2 connection 2 DO, DC 24 V, 0.5 A, short-cct-protected, PNP 2 DO, DC 24 V, 2.0 A, short-cct-protected, PNP 4 DO, DC 24 V, 0.5 A, short-cct-protected, PNP 4 DO, DC 24 V, 0.5 A, 2 connection, short-cct-protected, PNP 8 DO, DC 24 V, 0.5 A, NPN 8 DO, DC 24 V, 0.5 A, short-cct-protected, PNP 2 DO, AC 125 V, AC 0.5 A, DC 30 V, DC 1 A, isol o/pts, 2 C/O 2 DO, AC 230 V, 1 A, isolated outputs, 2 c/o contacts 2 DO, AC 230 V, DC 30 V, AC/DC 2 A, non-float, 2 make cntcts 2 DO, AC 230 V, DC 30 V, AC/DC 2 A, isol o/pts, 2 make cntcts Cat. No. 750-414 750-400 750-401 750-402 750-432 750-403 750-408 750-430 750-431 750-415 750-501 750-502 750-504 750-531 750-536 750-530 750-514 750-517 750-512 750-513 Price $ Digital Input modules / Digital Output modules - Indent 1) 2 DI, DC 24 V, 3.0 ms, Prox-Sw, 2 to 4 connection, PNP 2 DI, DC 24 V, 0.2 ms, Prox-Sw, 2 to 4 connection, PNP 2 DI, DC 24 V, 3.0 ms, 2 to 3 connection, PNP, with diagnostics 2 DI, DC 24 V, 3.0 ms, PNP, with diagnostics 4 DI, DC 24 V, 0.2 ms, 2 connection, PNP 4 DI, DC 24 V, 2 to 3 connection, PNP, pulse extension 10 ms 4 DI, DC 24 V, 0.2 ms, 2 to 3 connection, NPN 8 DI, DC 24 V, 3.0 ms, 1 connection, NPN 8 DI, DC 24 V, 0.2 ms, 1 connection, NPN 4 DI, AC/DC 24 V, 2 to 3 connection with power contacts 4 DI, AC/DC 24 V, 2 connection 2 DI, DC 48 V, 3.0 ms, 2 to 4 connection, PNP 2 DI, DC 110 V, configurable high-side or NPN 2 DI, AC 120 V, 2 to 4 connection 2 DI, AC 230 V, 2 to 4 connection 2 DI, NAMUR, Proximity switch acc. to DIN EN 50227 2 DI, DC 24 V, Intruder detection 4 DO, DC 5 V, 20 mA, short-cct-protected, PNP 2 DO, DC 24 V, 0.5 A, with diagnostics, short-cct-protected, PNP 2 DO, DC 24 V, 2.0 A, with diagnostics, short-cct-protected, PNP 4 DO, DC 24 V, 0.5 A, TYPE N, short-cct-protected, NPN 4 DO, DC 24 V, 0.5 A, with diagnostics, PNP 8 DO, DC 24 V, 0.5 A, with diagnostics, PNP 2 DO, Solid State Relay, AC/DC 230 V, 300 mA 2 DO, Solid State Relay, AC/DC 230 V, 500 mA, 3 A (< 30 s) 1 DO, AC 230 V, AC 16 A, isol output, 1 make cntct, bistable 750-410 750-411 750-418 750-421 750-433 750-422 750-409 750-436 750-437 750-423 750-428 750-412 750-427 750-406 750-405 750-425 750-424 750-519 750-506 750-508 750-516 750-532 750-537 750-509 750-522 750-523 750-523 Price Schedule ‘A4’ 1 - 22 Notes: ) WAGO indent items have a typical delivery time of 2-3 weeks. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue WFC2 WAGO I/O System – 750 Series Analogue Input / Analogue Output modules - Stocked 750-493 Description 4-channel, 0 - 20 mA, single ended, 12 Bit 2-channel, 0 - 20 mA, differential inputs, 14 Bit 2-channel, 4 - 20 mA, differential inputs, 12 Bit 4-channel, 4 - 20 mA, single ended, 12 Bit 2-channel, 4 - 20 mA, single ended, 15 Bit 2-channel, 4 - 20 mA, single ended, 12 Bit 2-channel, 4 - 20 mA, isolated differential inputs, 12 Bit 4-channel, DC 0 - 10 V, single ended, 12 Bit 4-channel, DC ± 10 V, single ended, 12 Bit 2-channel, DC ± 10 V, Diff. measurement input, 14 Bit 2-channel, DC0 - 30 V, Diff. measurement input, 14 Bit 2-channel, input module for RTDs, PT100 / RTD, 16 Bit 4-channel, 0 - 20 mA, 12 Bit 2-channel, 4 - 20 mA, 12 Bit 4-channel, 4 - 20 mA, 12 Bit 2-channel, DC 0 - 10 V, 12 Bit 4-channel, DC 0 - 10 V, 12 Bit 4-channel, DC ± 10 V, 12 Bit 750-452 Analogue Input / Analogue Output modules - Indent 1) 750-457 750-491 2-channel, 4-20 mA, HART, 4 variables per channel, FDT tool routing to DTM, 12 bit 3-phase power measurement, to 500 V AC, 1 A, 0.5 % error, 16 bit 3-phase power measurement, to 500 V AC, 5 A, 0.5 % error, 16 bit 2-channel, 0 - 20 mA, differential inputs, 12 Bit 2-channel, 0 - 20 mA, single ended, 12 Bit 2-channel, 0 - 20 mA, single ended, 15 Bit 2-channel, 4 - 20 mA, single ended, short circuit protected, 12 Bit 2-channel, 0 - 1 A AC/DC, differential inputs, 16 Bit 4-channel, DC 0 - 10 V, single ended, 12 Bit 2-channel, DC 0 - 10 V, single ended, 12 Bit 2-channel, AC/DC 0 - 10 V, differential inputs, 16 Bit 2-channel, DC 0 - 10 V, single ended, 16 Bit 2-channel, DC ± 10 V, differential inputs, 12 Bit 2-channel, DC ± 10 V, single ended, 14 Bit 4-channel, input module for RTDs, PT100 / RTD, 16 Bit 2-channel, thermocouple, K Type, -100 °C to +1370 °C, 16 Bit 2-channel, thermocouple, S Type, 0 °C to +1700 °C, 16 Bit 2-channel, thermocouple, T Type, -100 °C to +400 °C, 16 Bit 2-channel, thermocouple, +/- 120 mV, 16 Bit 2-channel, thermocouple, J Type, -100 °C to +1200 °C, 16 Bit 2-channel, thermocouple, E Type, -100 °C to +1000 °C, 16 Bit 2-channel, thermocouple, L Type, -25 °C to +900 °C, 16 Bit 2-channel, thermocouple, Configurable Temp range with I/O Check 1-channel input module for resistor bridge (Strain gauge), 16 Bit, 250 msec conversion 1-channel input module for resistor bridge (Strain gauge), 16 Bit, 65 msec conversion 2-channel, 0 - 20 mA, 12 Bit 2-channel, DC 0 - 10 V, 100 mA, 24 V, 8 Bit 2-channel, DC ± 10 V, 12 Bit Cat. No. 750-453 750-480 750-454 750-455 750-474 750-466 750-492 750-468 750-457 750-479 750-483 750-461 750-553 750-554 750-555 750-550 750-559 750-557 Price $ 1 750-482 750-493 750-493/000-001 750-452 750-465 750-472 750-473 750-475 750-459 750-467 750-477 750-478 750-456 750-476 750-460 750-469/00000 750-469/000001 750-469/000002 750-469/000003 750-469/000006 750-469/000008 750-469/000012 750-469/003000 750-491 750-491/000-001 750-552 750-560 750-556 750-557 Price Schedule ‘A4’ Notes: ) WAGO indent items have a typical delivery time of 2-3 weeks. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 23 WAGO I/O System – 750 Series Refer catalogue WFC2 Specialty / System modules - Stocked 1 750-404 Vibration Module 750-645 Vibration Sensor 750-925 Price Schedule ‘A4’ 1 - 24 Description Cat. No. 2-channel, Vibration velocity/Shock pulse, Bearing condition monitoring 750-645 Up/Down Counter, DC 24 V, 100 kHz 750-404 2-channel Up/Down Counter, DC 24 V / 16 Bit / 500 Hz 750-638 Serial Interface RS 232 C – Configurable 750-650/003000 Serial Interface RS 485 – Configurable 750-653/003000 Module Bus Extension, End Module 750-627 Module Bus Extension, Coupler Module 750-628 DC 24 V, passive 750-602 DC 24 V, max. 6.3 A, without diagnostics, with fuse-holder 750-601 DC 24 V, max. 6.3 A, with diagnostics, with fuse-holder 750-610 Filter Module, System and field side pwr supply filter with surge prot 750-626 Field Side Connection Module, DC 0 V 750-604 Field Side Connection Module, DC 24 V 750-603 Separation Module 750-616 End Module, to loop the internal bus 750-600 Specialty / System modules - Indent 1) Bluetooth, 2.4 GHz ISM band, Class 1 (100 metres), Master/Slave 750-644 External antenna for Bluetooth module 750-644, magnetic stand 758-912 Bluetooth, serial port adaptor for linking coupler/controller to laptop PC, Class 2 750-921 Tandem Piezo vibration sensor for Vibration module 750-645 750-925 Real Time Clock, 32 channel integrated time switch 750-640 2-channel Pulse Width Module, DC 24 V, short-cct-prot, PNP 750-511 SSI Transmitter Interface 750-630 750-631/000-004 Incremental Encoder Interface, TTL level squarewave 750-637 Incremental Encoder Interface, RS 422, cam outputs 750-634 Incremental Encoder Interface, DC 24 V Digital Impulse Interface 750-635 TTY-Serial Interface, 20 mA Current Loop 750-651 Data Exchange Module 750-654 DALI/DSI Master Module 750-641 AS-interface Master Module 750-655 RF-Receiver EnOcean 750-642 MP-Bus (Multi Point-Bus) Master Module 750-643 750-670 Stepper Controller, RS422, 24 V DC, 20 mA interfaces, 30 mA output 750-671 Stepper Controller, 24 V DC, 2-phase, 2 x 1.5 A outputs DC Drive controller, 24 V DC, 5 A output, incremental encoder interface, end stop inputs750-636 750-613 Bus Power Supply, DC 24 V Supply Module, 24 V DC input, selectable 5,8,10,12,15 V DC outputs, 0.5 A, 1 A @ 5 V DC 750-623 750-615 AC 120 V, max. 6.3 A, without diagnostics, with fuse-holder 750-612 AC/DC 230 V, without diagnostics, passive 750-609 AC 230 V, max. 6.3 A, without diagnostics, with fuse-holder 750-611 AC 230 V, max. 6.3 A, with diagnostics, with fuse-holder 750-624 Filter Module, Field side power supply filter with o/voltage prot 750-614 Field Side Connection Module, AC/DC 0 ...230 V 750-621 Separation Module with Power Contacts 750-622 Binary Spacer Module Notes: Price $ 1 ) WAGO indent items have a typical delivery time of 2-3 weeks. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue WFC2 WAGO I/O System – 750 Series ) 1 Accessories 750-960 750-970 Description Cat. No. PROFIBUS, Bus connector with D-SUB male connector, 9 pole 750-960 PROFIBUS, Bus connector with D-SUB male and female, 9 pole 750-970 INTERBUS (IN), Bus connector with D-SUB female, 9 pole 750-961 INTERBUS (OUT), Bus connector with D-SUB male, 9 pole 750-962 CANopen, Bus connector with D-SUB female connect, 9 pole 750-963 CC-Link, Bus connector with D-SUB male connecter, 9 pole 750-965 Multi-Port Device Taps, 2 trunk Cable (in/output), 4 drop cables 810-900/000-001 Multi-Port Device Taps, 2 trunk Cable (in/output), 2 drop cables 810-901/000-001 Multi-Port Device Taps, 2 trunk Cable (in/output), 1 & 2 drop cables 810-902/000-001 Programming/configuration cable from laptop/PC to Controller/D-Connector Bluetooth, serial port adaptor for linking coupler/controller to laptop PC, Class 2 Programming/configuration cable from laptop/PC to Controller, USB-connector Power Supply for AS-Interface, Input 90 to 264 V AC, Output 30.5 V DC, 3.0 A Power Supply, Input 90 to 264 V AC, Output 1.0 A V DC, Cage Clamp connectors Power Supply, Input 90 to 264 V AC, Output 2.5 A V DC, Cage Clamp connectors 750-920 750-921 750-923 787-692 787-602 787-612 Price $ 1 Extended Temperature Range from -20° to +60 °C 288-824 810-901/000-001 Ethernet Controller, 100 Mbit/s, EXT Modbus Controller RS-485, 150-19, 200 Bd EXT Modbus Controller RS-485, 1.2-115.2 KBd EXT Profibus coupler, DP/V1, 12 MBd, EXT Profibus controller, DP/V1, 12 MBd, EXT CANopen coupler, EXT 2 Digital Input, 24 V DC, 3.0 msec, EXT 4 Digital Input, 24 V DC, 3.0 msec, EXT 8 Digital Input, 24 V DC, 3.0 msec, EXT 4 Digital Output, 24 V DC, 0.5 A, EXT 8 Digital Output, 24 V DC, 0.5 A, EXT 2 Analogue Input, 4-20 mA, Single Ended, EXT 4 Analogue Input, 4-20 mA, Single Ended, EXT 4 Analogue Input, 4-20 mA, Differential, EXT Supply module, 24 V DC, EXT Serial Interface, RS-485, 9600/n/8/1/5 Byte Cont., EXT Serial Interface, RS-485, Configurable, EXT 750-841/025-000 750-812/025-000 750-815/025-000 750-333/025-000 750-833/025-000 750-337/025-000 750-400/025-000 750-402/025-000 750-430/025-000 750-504/025-000 750-530/025-000 750-466/025-000 750-455/025-000 750-454/025-000 750-602/025-000 750-653/025-018 750-653/025-000 810-902/000-001 750-921 Price Schedule ‘A4’ Notes: 1 ) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 25 Refer catalogue WFC2 WAGO I/O System – 857 Series JUMPFLEX Transducers 1 Multi-Talented With High Profile A complete product line is available, bringing each signal into shape. The perfect match of housing and electronics is the key to a highly successful device. This goal has been achieved by WAGO with the new family of transducers and relay modules Series 857. Features: “True” 6.0 mm/0.236” width Extended range of temperatures from -25 °C to +70 °C “Safe isolation” with 2.5 kV test voltage Configuration via DIP switch CAGE CLAMP® S connection – fast – reliable – maintenance free For Extreme Applications Extended range of temperatures from -25 °C to +70 °C allows for wide application areas. Vibration Proof - Fast - Maintenance Free CAGE CLAMP® S connection for all types of wires. 1 - 26 solid fine-stranded ferruled AWG 28 … 12 (0.08 mm2 … 2.5 mm2) AWG 22 … 12 (0.34 mm2 … 2.5 mm2) AWG 22 … 14 (0.25 mm2 … 1.5 mm2) For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue WFC2 WAGO I/O System – 857 Series JUMPFLEX Transducers ) 2 Amplifier Transducers Description Specifications Cat. No. Isolation Amplifier Input: 0(4) - 20 mA, 0(1) - 5 V, 0(2) - 10 V 857-400 (Configuration via DIP Switch) Output: 0(4) - 20 mA, 0(1) - 5 V, 0(2) - 10 V Isolation Current Amplifier Input: 0(4) - 20 mA (Fixed Settings) Output: 0(4) - 20 mA Isolation Voltage Amplifier Input: 0(2) - 10 V (Fixed Settings) Output: 0(2) - 10 V Price $ 1 857-412 857-411 Power Supply Transducers Isolation Amplifier, Configurable Repeater Power Supply Input: 0(4) - 20 mA (Configuration via DIP Switch) Output: 0(4) - 20 mA, 0(1) - 5 V, 0(2) - 10 V Repeater Power Supply, HART Input: 4 - 20 mA (Fixed Settings) Output: 4 - 20 mA Signal Splitter Input: 0(4) - 20 mA, 0(1) - 5 V, 0(2) - 10 V (Configuration via DIP Switch) Output: 2 x 0(4) - 20 mA 857-420 857-421 857-423 Isolator Transducers Passive Isolator, 1 Channel Input: 0(4) - 20 mA (Fixed Settings) Output: 0(4) – 20 mA Passive Isolator, 2 Channels Input: 0(4) - 20 mA (Fixed Settings) Output: 0(4) - 20 mA 857-451 857-452 Temperature Transducers Temperature Transducer for RTDs Transducer for RTDs Input: Pt 100, Pt 200, Pt 500, Pt 1000 (Configuration via DIP Switch) Output: 0(4) - 20 mA, 0(2) - 10 mA, 857-800 0(2) - 10 V, 0(1) - 5 V Transducer for RTDs Input: Pt 100, Pt 200, Pt 500, Pt 1000 (Configuration via DIP Switch Output: 0(4) - 20 mA, 0(2) - 10 mA, or Software) 1) 0(2) - 10 V, 0(1) - 5 V Transducer for Thermocouples Input: Type J: -150 °C ... +1200 °C / (Configuration via DIP Switch) Type K: -150 °C ... +1350 °C 857-801 857-810 Output: 0(4) - 20 mA, 0(2) - 10 mA, 0(2) - 10 V, 0(1) - 5 V Transducer for Thermocouples Input: Type J: -150 °C ... +1200 °C / (Configuration via DIP Switch Type K: -150 °C ... +1350 °C or Software) 1) Output: 0(4) - 20 mA, 0(2) - 10 mA, 857-811 0(2) - 10 V, 0(1) - 5 V Programming/configuration cable from laptop/PC to Controller, D-Connector 750-920 Bluetooth, serial port adaptor for linking coupler/controller to laptop PC, Class 2 750-921 Programming/configuration cable from laptop/PC to Controller, USB-connector 750-923 Highest Safety All devices provide “safe isolation” with 2.5 kV test voltage to EN 61140. Flexibility at its Finest Configuration via DIP switch. Temperature transducers can also be configured via software. Price Schedule ‘A4’ Notes: 1 2 ) WAGO I/O Check Software (P/N 759-302 refer page 1 - 27) and WAGO Programming cable. ) Please check availability. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 27 WAGO I/O-System – 750 Series Intrinsically Safe System for applications in Hazardous Areas 1 WAGO-I/O-SYSTEM 750 - Now IECex approved, test certificates available Today’s development shows that many chemical and petrochemical companies have production plants, production and process automation machines in operation, which use gas-air or dust-air mixtures which can be explosive. For this reason, the electrical components used in such plants and systems must not pose a risk of explosion resulting in injury to persons or damage to property. The WAGO-I/O-SYSTEM 750 is designed for use in both hazardous and non-hazardous environments. Using fieldbus technology in hazardous environments can be very time consuming and cost intensive and is only made possible in a limited way. When used in hazardous areas of Zone 2, the WAGO-I/O-SYSTEM 750 offers a safe, easy an economical connection to the sensors and actuators of Zones 0 and 1. The EExi I/O modules were specially developed for this purpose. They build up an intrinsically safe section, which can be integrated into a standard fieldbus node, offering all the advantages of state-of-the-art fieldbus technology (e.g. fieldbus independency, flexibility, modularity, programmability, reliability, cost effectiveness). EExi Modules ) 1 Description Cat. No. EExi 1 channel digital input 750-435 EExi 2 channel digital input 750-438 EExi 2 channel digital output 750-535 EExi 1 channel analogue input 4-20 mA 750-485 EExi 1 channel analogue input RTD 750-481 EExi 1 channel analogue output 0-20 mA 750-585 EExi power supply 24 Volt fused 750-625 Price $ Now IECex approved, test certificates available 750-485 Price Schedule ‘A4’ 1 - 28 Notes: ) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue WFC2 WAGO I/O-System – 750 Series PROFIsafe The WAGO-I/O-System 750 integrates modules with SAFETY functionality into the fieldbus node in accordance with industry standards. This allows their use in safety applications up to category 4 in accordance with EN 954-1 or SIL 3 according to base standard IEC 61508 and AK 6-(DIN V 19250). The advantages Q 750-660 Q Q Q The same input module allows the connection of emergency switches, protection door switches, two-handed control devices, mode selectors, as well as other hardware based safe sensors. An output module can operate outputs with stop category 0 or 1. The outputs are also monitored for cross short circuits. Q The power switch module offers the possibility to switch off various 24 V output modules (up to safety category 3) that shall be combined in one safety area. All inputs of a module are monitored for cross short circuits which makes it possible to combine all sensors in one single cable. Q All safety modules are connected to the master station via the PROFIsafe protocol. The master station takes care of initialisation, setting parameters and assignments. Status, configuration and diagnostics are available in every module. 1 750-665 PROFIsafe modules 750-666 Price Schedule ‘A4’ 1 ) Description Cat. No. Input - [8 Digital Inputs (Cat 2)] or [4 Digital Inputs (Cat 4)] Output - [(4 DO + 4 DI) - (Cat 2)] or [(2 DI + 2 DO) - (Cat 4)] Power Switch - [1 DO (Cat 3)] or [1 DI + 1 DO] - (Cat 4) Input - [4 Digital Inputs (Cat 2)] or [2 Digital Inputs (Cat 4)] Input - [8 Digital Inputs (Cat 2)] or [4 Digital Inputs (Cat 4)] Output -[(4 DO + 4 DI) (Cat 2)] or [(2 DI + 2 DO (Cat 4)] 750-660 750-665 750-666 753-661 753-662 753-667 Notes: Price $ ) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 29 WAGO I/O-System – 750 Series Vibration monitoring Vibration monitoring and analysis is a well established and commonly used method of predictive maintenance. Motors, pumps, gear boxes, fans and many other types of rotating components of mechanical systems can fail unexpectedly and result in major production losses and expensive repairs. Many of these failures can be predicted by measuring the normal vibration levels of rotating components and watching for increases. Vibration monitoring and analysis equipment traditionally has been expensive and often separate to, or awkwardly integrated into factory control and maintenance systems. WAGO has developed a vibration monitoring system that overcomes many of the problems with existing vibration systems. The WAGO system consists of a vibration sensor that constantly measures both the mean value of the vibration severity and the “shock pulse” value. Two such sensors can be monitored by the new WAGO vibration module 750-645. The new module is fully compatible with all of the other modules in the WAGO remote I/O 750/753 series and with all WAGO standard couplers and WAGO controllers. This allows the vibration monitoring information to be transmitted back to a central control system along any of the popular fieldbus types. Limits can be set for the measured values of vibration and if these limits are exceeded then alarms can be raised and further investigation can be conducted, or if higher limits are exceeded the module can trigger a slow down, or a shut down of the equipment to protect it from damage. The module employs coloured LEDs to locally display the status of the module and to show if the alarm, or shut down limits have been exceeded. The new WAGO Vibration system thus provides another reason to choose WAGO I/O for all of your future remote I/O needs. 1 Ordering details Description Cat. No. 2-channel, Vibration velocity/Shock pulse, Bearing condition monitoring Tandem Piezo vibration sensor for Vibration module 750-645 750-645 750-925 Price $ Price Schedule ‘A4’ 1 - 30 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included WAGO I/O-System – 750 Series AS-i Fieldbus System 1 AS-i bus - up to 100 metres, or 300 metres with two repeaters AS-i Master and Slave Modules 1 ) Ordering details Description Cat. No. Price $ Master Module AS-interface Master Module, Specification 2.1 Compliant, Controls up to 62 AS- 750-655 interface Slaves, Gateway to other Fieldbus Systems, Compatible with “Safety at Work”, Supports Analogue Data Transmission, Cyclic and Acyclic Communications, Supports Extended Diagnostics, Configurable with WAGO-IO-CHECK IP 67 I/O Modules 751-5701 IP 20 Casing 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), Standard Addressing 751-3001 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), A/B Extended Addressing 751-3002 4 Digital Outputs, 24 V DC/2A, Standard Addressing 751-4001 4 Digital Outputs, 24 V DC/2A, 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), 751-5201 Standard Addressing 3 Digital Outputs, 24 V DC/2A, 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), 751-5202 A/B Extended Addressing IP 20 I/O Modules 751-4001 IP 67 Casing 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), Standard Addressing 751-3501 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), A/B Extended Addressing 751-3502 4 Digital Outputs, 24 V DC/2A, Standard Addressing 751-4501 4 Digital Outputs, 24 V DC/2A, 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), 751-5701 Standard Addressing 3 Digital Outputs, 24 V DC/2A, 4 Digital Inputs, 24 V DC, 2 or 3 Wire Sensors (PNP), 751-5702 A/B Extended Addressing Power Supply Input Voltage 100-240 V AC at 50 - 60 Hz or 140 - 300 V DC, Output Voltage For As-i safe components refer to NHP Price Schedule ‘A4’ 787-692 30.5 V DC at 3A, Overload Protection WAGO-I/O-CHECK Configuration, start-up, and diagnostic software tool Notes: 759-302 ) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 31 THINK QUALITY SERVICE. THINK NHP. NHP is shaped by a team of over 850 quality staff dedicated to providing ‘what you want, when, where and how you want it’. As an integrated group that spans across six key business areas, the unique and complete NHP package rests on a strong team of staff that pride itself on a shared set of core company values. r 1BTTJPOGPS$VTUPNFST r $PNNJUNFOUUP1FSGPSNBODF r $POTJTUFODZ r &OFSHZ r "EBQUJWFOFTTUP$IBOHF r *OUFHSJUZ Make NHP part of your business. Think Quality Service. Think NHP. 1300 NHP NHP nhp.com.au 0800 NHP NHP nhp-nz.com Refer catalogue WFC2 WAGO I/O-System Programming and diagnostic software I/O PRO WAGO-I/O-PRO 32 is a programming and visualisation tool, allowing users to develop SPS applications for the Programmable Fieldbus Controller from the WAGO-I/O-SYSTEMS 750. WAGO-I/O-PRO conforms to IEC 61131-3. This standard defines the requirements fulfilled by a programming system as well as five programming languages for PLCs. The languages IL, LD, FBD, ST and FC are supported. For every automation task, the appropriate language can be chosen. The software meets the increasing requirements of control program development, for example re-usability or modularisation. Q Powerful translation of the programming languages Q Automatic declaration of variables Q Librarian / library maintenance Furthermore, integrated test and diagnostic functions facilitate and speed up PLC working processes. Q Online status indication in the program code Q Offline simulation Q Integrated visual display of internal and external markers Q Storage and graphic display of project variables Cat. No. Description WAGO I/O PRO ) ) 1 1 Price $ 759-332 2 WAGO I/O PRO CAA ) ) 1 2 759-333 I/O CHECK WAGO-I/O-CHECK is a WindowsTM application for the check of inputs and outputs and the display of nodes of the WAGO-I/O-SYSTEM 750. The software is easy to handle and it is not necessary to connect the node to a fieldbus system. The software reads out the node configuration and displays it as a graphic on the screen. This graphic can be printed out along with a configuration list, together being a complete documentation. With WAGO-I/O-CHECK it is possible to display and to determine the process data of the bus modules. The field wiring including all sensors and actuators, can thus be checked before startup. The communication between WAGO-I/O-CHECK and the node is made via the communication cable (included with the delivery) which is connected to the coupler and to a serial interface of the PC. Cat. No. Description WAGO I/O CHECK ) 1 Price $ 759-302 Accessory/Spare Description Cat. No. Programming/configuration cable from laptop/PC to Coupler/controller, D-connector 750-920 Bluetooth, serial port adaptor for linking coupler/ controller to laptop PC, Class 2 750-921 Programming/configuration cable from laptop/PC to Controller, USB-connector 750-923 Note: Price $ ) Includes: manual (electronic), communications cable and installation disks. ) The software choice depends on the hardware and firmware that is being used. Ask your NHP automation specialist for advice. WAGO indent items have a typical delivery time of 2-3 weeks. 1 2 Price Schedule ‘A4’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 33 Refer catalogue WFC2 WAGO I/O-System – 750 Series Starter Kits 1) 1 Description Cat. No. Ethernet Starter Kit 1 Price $ 750-841KIT Ethernet Starter Kit 2 750-842KIT Profibus Starter Kit 750-833KIT ASinterface Starter Kit 750-655KIT ETHERNET StarterKit 1 Item No. 750-841 KIT Content: Type Fieldbus controller + basic components Description Item No. ETHERNET TCP/IP 10/100 MBit/s 750-841 ETHERNET StarterKit 2 Item No. 750-842 KIT Content: Type Fieldbus controller + basic components Basic components Type Digital input module Digital output module End module Power supply unit Software Programming software CD-ROM Tools & Docs Programming cable Description ETHERNET TCP/IP 10 MBit/s Item No. 750-842 Description 2 DI 24 V DC 3.0 ms 2 DO 24 V DC 0.5 A Item No. 750-400 750-501 750-600 787-602 759-312 759-911 0888- 0412/0001-010 750-920 24 V DC 1.3 A WAGO DLL MODBUS/TCP WAGO-I/O-PRO CAA Documentation PROFIBUS StarterKit Item No. 750-833 KIT Content: Type Fieldbus controller Input module Input module Output module Input module Output module End module Power supply unit DEMO Programming software CD-ROM IP 67 Description PROFIBUS DP/ V1 12 MBd 2 DI 24 V DC 3.0 ms 4 DI 24 V DC 3.0 ms 8 DO 24 V DC 0.5 A 2 AI 0 -10 V 4 AO 0-10 V 24 V DC 1,3 A WAGO-I/O-PRO CAA Documentation/GSD file Item No. 750-833 750-400 750-402 750-530 750-478 750-559 750-600 787-602 0888-0412/0001-0101 IP 20 AS-Interface Expansion Kit Item No. 750-655 KIT 1) AS-interface power supply unit Content: Type Specialty module Power supply unit AS-Interface slave IP 67 AS-Interface slave IP 20 Software Bus cable Bus cable CD-ROM AS-interface master Note: Price Schedule ‘A4’ 1 - 34 Description Item No. AS-Interface master (M3) V.2.1 750-655 AS-Interface 30.1 V/3A 787-692 4 IN/3 OUT 24 V/2 A 751-5202 4 IN/3 OUT 24 V/2 A 751-5702 WAGO-I/O-CHECK 759-302 1 meter AS-Interface, yellow 2x1.5 1 meter control cable, OB 500 2x1.0 Documentation 0888-0412/0001-0101 1 ) AS interface expansion kit requires a WAGO controller and an end module. WAGO indent items have a typical delivery time of 2-3 weeks. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue WFC2 WAGO I/O-System – 753 Series Quick connect modules 1 Quick release by lever Quick release by lever Quick release by lever Quick release by screwdriver Easy module removal Easy module removal Coding Elements Easy insert Removeable terminals Miniature marking Quick connect Secure cable location Colour coded modules Diagnosis and status shown by LED Signal tracing with wired conductors For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 35 Refer catalogue WFC2 WAGO I/O-System – 753 Series Quick connect modules 1)2) Digital Input modules Description 1 753-400 2 DI, DC 24 V, 3.0 ms, 2 to 4 connection, PNP Cat. No. 753-400 2 DI, DC 24 V, 0.2 ms, 2 to 4 connection, PNP 753-401 2 DI, DC 24 V, 3.0 ms, Prox-Sw, 2 to 4 connection, PNP 753-410 2 DI, DC 24 V, 0.2 ms, Prox-Sw, 2 to 4 connection, PNP 753-411 2 DI, DC 24 V, 3.0 ms, 2 to 3 connection, PNP, with diagnostics 753-418 2 DI, DC 24 V, 3.0 ms, PNP, with diagnostics 753-421 4 DI, DC 24 V, 3.0 ms, 2 to 3 connection, PNP 753-402 4 DI, DC 24 V, 3.0 ms, 2 connection, PNP 753-432 4 DI, DC 24 V, 0.2 ms, 2 to 3 connection, PNP 753-403 4 DI, DC 24 V, 0.2 ms, 2 connection, PNP 753-433 4 DI, DC 24 V, 2 to 3 connection, PNP, pulse extension 10 ms 753-422 4 DI, DC 24 V, 3.0 ms, 2 to 3 connection, NPN 753-408 4 DI, DC 24 V, 0.2 ms, 2 to 3 connection, NPN 753-409 8 DI, DC 24 V, 3.0 ms, 1 connection, PNP 753-430 8 DI, DC 24 V, 0.2 ms, 1 connection, PNP 753-431 4 DI, AC/DC 24 V, 2 connection 753-415 4 DI, AC/DC 24 V, 2 to 3 connection with power contacts 753-423 4 DI, AC/DC 42 V, 2 connection 753-428 2 DI, DC 48 V, 3.0 ms, 2 to 4 connection, PNP 753-412 2 DI, DC 110 V, configurable high-side or NPN 753-427 2 DI, AC 120 V, 2 to 4 connection, PNP 753-406 2 DI, AC 230 V, 2 to 4 connection, PNP 753-405 2 DI, NAMUR, Proximity switch acc. to DIN EN 50227 753-425 2 DI, DC 24 V, Intruder detection 753-424 8 DI, DC 5 to 12 V, 0,2 ms, PNP 753-434 4 DI, AC 90 to 230 V 753-440 Price $ Digital Output modules BxH 1) xT (mm) 12x65x100 Price Schedule ‘A4’ 1 - 36 2 DO, DC 24 V, 0.5 A, short-cct-protected, PNP 753-501 2 DO, DC 24 V, 2.0 A, short-cct-protected, PNP 753-502 2 DO, DC 24 V, 0.5 A, with diagnostics, short-cct-protected, PNP 753-506 2 DO, DC 24 V, 2.0 A, with diagnostics, short-cct-protected, PNP 753-507 4 DO, DC 24 V, 0.5 A, short-cct-protected, PNP 753-504 4 DO, DC 24 V, 0.5 A, 2 connection, short-cct-protected, PNP 753-531 4 DO, DC 24 V, 0.5 A, TYPE N, short-cct-protected, NPN 753-516 8 DO, DC 24 V, 0.5 A, short-cct-protected, PNP 753-530 2 DO, Solid State Relay, AC/DC 230 V, 300 mA 753-509 2 DO, AC 125 V, AC 0.5 A, DC 30 V, DC 1 A, isol o/pts, 2 c/o 753-514 2 DO, AC 230 V, 1 A, isolated outputs, 2 c/o contacts 753-517 2 DO, AC 230 V, DC 30 V, AC/DC 2 A, non-float, 2 make cntcts 753-512 2 DO, AC 230 V, DC 30 V, AC/DC 2 A, isol o/pts, 2 make cntcts 753-513 8 DO, DC 12 V, 1.0 A 753-534 4 DO, AC 230 V, 0.25 A 753-540 Notes: ) Same size as the 750 series. ) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. 1 2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue WFC2 WAGO I/O-System – 753 Series Quick connect modules 2) Analogue Input modules 753-400 Description Cat. No. 2-channel, 0 - 20 mA, Diff. 753-452 4-channel, 0 - 20 mA, single ended 753-453 2-channel, 0 - 20 mA, single ended 753-465 2-channel, 0 - 20 mA, single ended, 16 Bit 753-472 2-channel, 0 - 20 mA, Differential inputs 753-480 2-channel, 4 - 20 mA, Diff. 753-454 4-channel, 4 - 20 mA, single ended 753-455 2-channel, 4 - 20 mA, single ended, 16 Bit 753-474 2-channel, 4 - 20 mA, single ended 753-466 2-channel, 4 - 20 mA, Isolated differential inputs 753-492 2-channel, 0 - 1 A AC/DC, Diff. 753-475 4-channel, DC 0 - 10 V, single ended 753-459 2-channel, DC 0 - 10 V, single ended 753-467 2-channel, DC 4 - 20 mA, single ended 753-466 2-channel, AC/DC 0 - 10 V, Diff. 753-477 2-channel, DC 0 - 10 V, single ended 753-478 2-channel, DC ± 10 V, Diff. 753-456 4-channel, DC ± 10 V, single ended 753-457 2-channel, DC ± 10 V, Diff. measurement input 753-479 2-channel, DC ± 10 V, single ended 753-476 2-channel, DC 0 - 30 V, Diff. measurement input 753-483 2-channel, input module for RTDs, PT100 / RTD 753-461 2-channel, t/cpls, open-cct, K type 753-469 2-channel, 4-20 mA, HART, up to 4 variables per channel, 12 bit 753-482 Price $ 1 Analogue Output modules 2-channel, 0 - 20 mA 753-552 2-channel, 4 - 20 mA 753-554 2-channel, DC 0 - 10 V 753-550 4-channel, DC 0 - 10 V 753-559 2-channel, DC ± 10 V 753-556 4-channel, DC ± 10 V 753-557 Speciality modules Up/Down counter, DC 24 V, 100 kHz 753-404 2-channel Up/Down counter, DC 24 V / 16 Bit / 500 Hz 753-638 Digital impulse interface 753-635 Serial interface RS 232 C 753-650 BxH )xT (mm) 12x65x100 Serial interface RS 485 KNX/TP1, KNX/EIB 1 753-653 753-646 System modules Field Side connection module, DC 0 V 753-604 Field Side connection module, DC 24 V 753-603 Field Side connection module, AC/DC 0 ...230 V 753-614 Connector (required for all 753 Series modules) 753-110 Accessories Coding element Series 753 Price Schedule ‘A4’ Notes: 753-150 ) Same size as the 750 series. ) Please check availability. The WAGO I/O range is frequently increased, and extensive technical literature is available. Contact NHP. 1 2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 37 ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system 1 What is Dupline® ? Dupline is a field- and installation-bus that offers unique solutions for a wide range of applications in building automation, water distribution, energy management, railway systems and many other areas. The system is capable of transmitting multiple digital and analogue signals over several kms, via an ordinary 2-wire cable. Its modular design and simple operating principle enable even novices to implement its use in new or existing applications. Solutions are engineered by combining products from the wide range of Dupline® modules, including digital and analogue I/O modules, PLC and PC interfaces, HMIs and Modems. All modules in an installation connect to the same 2-wire cable which is used to exchange data between modules and between a central controller and modules. Dupline© is typically used as a remote I/O system, creating a link between field devices, such as sensors, contactors, valves, pushbuttons etc. and a central Monitoring Controller, which may be a PLC, PC or the Dupline® Controller. Dupline® can also be used as a simple wire replacement system where signals are transmitted peer-to-peer without involving a controller or other intelligent unit. The Dupline® signals can be transmitted not only on copper wire, but also on fibre optic cable, via radio modem, on leased telephone lines or via GSM Modem. Dupline® has proven its performance in more than 100,000 installations worldwide since 1986. And even though the latest ASIC technology is used today, the new Dupline® modules are still compatible with those installed 17 years ago. Example: Dupline® used as wire replacement system (peer-to-peer) Channel Generator 2 wire cable Dupline (up to 10 km) I/O Modules • Digital • Analogue I/O Modules • Digital • Analogue Parallel wiring of traditional automation systems is often costly and complicated. Each sensor and actuator needs its own wiring, which makes the initial installation cost high. Expansion is also a problem, and even ongoing maintenance costs are high. Therefore, serial bus technology has become an increasingly important part of the concepts of electrical installations for buildings, industrial processes and public services. There are numerous advantages in using a bus system, which replaces a bundle of parallel wires with a single 2-wire cable. Easy and fast installation reduces labor cost significantly, and the possibility of expanding the system using the existing cabling makes it easy to adapt to changing needs. Bus systems also provide cost-effective access to a larger number of signals. This supports the Traditional Dupline increasing demand for automation systems to collect and Installation Installation use more and more data to optimise cost and performance. NOT APPROVED FOR SIL3 SAFETY APPLICATIONS 1 - 38 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system Why use Dupline® ? Many criteria have to be considered when selecting a fieldbus system. These include transmission distance capabilities, easy operation, noise immunity, topology and response-time. And cost-effectiveness, of course, is always a factor. Therefore, it is important to define the key application requirements in order to optimise the bus system for the specific task. The strength of the Dupline® system lies in a unique set of features that enable elegant, flexible and cost effective solutions for a wide range of applications. Most of these features originate from the effective time-division multiplex technology used. The efficiency of the protocol allows a low carrier frequency of 1 kHz, providing long transmission distance and superior noise immunity. Hence, Dupline® is capable of transmitting multiple digital and analogue signals over distances up to 10 Km, via a non-shielded, non-twisted 2-wire cable, without using repeaters. These unique Dupline® features provide considerable cost savings in many installations, especially when existing ordinary cables are available for use. Another important Dupline® characteristic is easy handling in all project phases. It does not take an engineering degree to work with Dupline®. No PC is required, since the coding of addresses and testing is carried out by means of simple handheld devices. There is no need for special cables and terminations, and there are no cable routing restrictions as with many other Fieldbuses. It is so simple and easy to implement, that many customers do their own installation, troubleshooting and maintenance, thus eliminating the need for costly service and installation contracts. Dupline® is system independent and open for interfacing with basically any kind of controller. Serial interfaces with Modbus and dedicated PLC protocols, together with gateways for ProfibusDP and DeviceNet™, enable easy and flexible interfacing to PLCs, PCs and dedicated controllers. 1 Dupline® features at a glance Q Up to 10 km transmission distance without repeaters Q Easy handling Q Extremely noise immune Q Unrestricted topology Q Flexible Q No special cable requirements Q Existing cable can be used Q Bus-powered devices available Q Flexible interfacing to PLCs and PCs Q Transmission via GSM modem, radio modem or fibre optics possible Q Proven performance in more than 150,000 installations Q Cost-effective Example: Dupline® used as Remote I/O for PLC Dupline® # 1 I/O Modules • Digital • Analogue • Counters RS 485 / RS 232 Modbus Profibus-DP DeviceNet Interface Dupline® # 2 I/O Modules • Digital • Analogue • Counters Interface NOT APPROVED FOR SIL3 SAFETY APPLICATIONS For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 39 ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system G50101106 Bus-Powered single input module 1 G34296470 Analogue inputs IN PU TM OD UL ES Product categories The wide range of Dupline® products for industrial applications and building automation can be divided into different categories depending on the function they perform on the network. By combining products from the various categories, complete solutions can be engineered for a multitude of different applications. G88104401 Self-powered light switch input module Central units G4420740 Counter module Being the heart of the system, the Dupline® Central Unit produces the carrier signal allowing all the other modules on the network to communicate with each other. There is always one, and only one, central unit in a Dupline® network. Some central units have built-in control and/or interfacing functions. ADDRESS CONFIGURATION VT565W Touch screen 1) Digital and Analogue input modules These modules are used to collect the digital and analogue signals in the field for transmission via Dupline®. They connect to contacts, voltages and analogue signal sources with DIN-norm outputs like 4-20 mA. A Counter module for counting pulses from energy meters is also available. Digital and Analogue output modules G34205501 Digital inputs G82452574 Temp. display GAP1605 Handheld coding unit VT50 Text Display 1) These modules are used to output signals transmitted on Dupline® to field devices. The digital types are available with relay or transistor outputs and the analogue types have DIN-norm outputs like 4-20 mA. They typically connect to contactors, lamps, instruments, drives etc. ES L DU Sensors Dupline® sensors are self-powered devices that detect or measure physical states directly. The digital types can detect presence of people, magnet proximity, metal proximity or water leakage, while the analogue types measure temperature or light intensity. Y LA SP DI MO G54606606 LED status indicator Interface products Modems and converters In many applications, the Dupline® signals need to be controlled and monitored from a central PLC or PC. To accommodate easy and flexible interfacing there are a number of products available for interfacing via serial ports (RS 232 or RS 485) or via standard Fieldbus connections (Profibus-DP and DeviceNet™). Sometimes it is necessary to convert the Dupline® signal for transmission on media other than copper wire. Via modems and converters Dupline® can be transmitted on telephone cables, wireless via radio modems, on optical fibre or via GSM modem. The transmission distance on copper wire can be extended by using the Dupline repeater. NOT APPROVED FOR SIL3 SAFETY APPLICATIONS 1 - 40 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system G88301143 Bus-powered single relay output 1 G34404443 Digital inputs/outputs ES L DU T PU MO T OU G34485324 Light dimmer G34396470 Analogue outputs G38000015 Central unit and interface G34305545 Digital outputs Optional Direct Interface to PLCs and PCs via • Modbus (RS 232, RS 485) • Dedicated PLC protocols • Profibus-DP • DeviceNet G34930000 Optical converter MODEMS AND CONVERTERS D38920000 Repeater TEST UNIT G34910040 Private line modem GTU8 Handheld Bus-powered test unit Notes: ) GTI50 adaptor required. 1 Display and HMIs Coding and Testing tools The products in this category are used to perform the interface between the users and the Dupline® network. The status of digital and analogue signals can be read out on Text Displays, Panel Meters, Touchscreens or LED indicators and control of signals is also possible. No PC or other advanced tool is required for address coding of Dupline® modules or for testing an installation. Instead, these tasks are performed by means of two simple handheld devices that are intuitive in use. NOT APPROVED FOR SIL3 SAFETY APPLICATIONS For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 41 ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system – Components Channel Generators 1 Description G3490 Cat. No. Price $ Standard Channel Generator, up to 128 channels - 24 V AC P.S. G34900000024 selectable 115 V AC P.S. G34900000115 230 V AC P.S. G34900000230 15-30 V DC P.S. G34900000824 Ch.G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC, 115-230 V AC P.S. G38000015230 2 x RS 232 ports 10-30 V DC P.S. G38000015800 Ch.G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC, 115-230 V AC P.S. G38001015230 2 x RS 232 ports, with internal GSM modem. (Antenna & 10-30 V DC P.S. G38001015800 Ch.G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC, 115-230 V AC P.S. G38000016230 2 x RS 232 ports, with 1 RS 485 port 10-30 V DC P.S. G38000016800 Ch.G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC, 115-230 V AC P.S. G38001016230 2 x RS 232 ports, with internal GSM modem & 1 RS 485 10-30 V DC P.S. G38001016800 Ch. G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC, 115-230 V AC P.S. G38000036230 2 RS 232 ports, 1 RS 485 port, Data Logging 10-30 V DC P.S. G38000036800 Ch. G. Controller, 4 DI 6-30 V DC, 4 DO PNP <35 V DC, 115-230 V AC P.S. G38001036230 SIM card required) port. (Antenna & SIM card required) 2 RS 232 ports, 1 RS 485 port, Data Logging, GSM modem, 10-30 V DC P.S. G38001036800 (Antenna and sim card required) G3800 Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt 20-30 V DC P.S. G34960000700 20-30 V DC P.S. G34960001700 20-30 V DC P.S. G34960002700 20-30 V DC P.S. G34960003700 20-30 V DC P.S. G34960004700 20-30 V DC P.S. G34960005700 20-30 V DC P.S. G34960006700 20-30 V DC P.S. G34960007700 20-30 V DC P.S. G34960008700 20-30 V DC P.S. G34960009700 20-30 V DC P.S. G34960010700 20-30 V DC P.S. G34960011700 20-30 V DC P.S. G34960012700 protocols for Optolink PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for LG PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for G.E.-Fanuc PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for Mitsubishi FX PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for Omron PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for Modbus Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for Allen-Bradley PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for Schneider PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt G3496 protocols for Koyo PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for Matsushita PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for Siemens PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for Toshiba PLCs Ch.G., Plug and Play RS 232/RS 485 interface, inbuilt protocols for IDEC PLCs Price Schedule ‘A7’ 1 - 42 NOT APPROVED FOR SIL3 SAFETY APPLICATIONS For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system – Components Channel Generators/Gateways G3891 Description Cat. No. Price $ 115-230 V AC P.S. G38910020230 115-230 V AC P.S. G38910021230 Ch. G. DeviceNet slave gateway, 500 kBaud, 128 I/O 115-230 V AC P.S. G38910050230 Ch. G. Lonworks gateway, 78 kbps, 128 I/O Ch. G. Profibus DP slave gateway, 12 Mbaud, 128 I/O, 1 PNO certified Ch. G. Profibus DP slave gateway, 12 Mbaud, 128 I/O, PNO certified, analogue output multiplex G3890 G3420 115-230 V AC P.S. G38910051230 Ch. G. Modbus TCP slave gateway, 10/100 Mbit, 128 I/O 115-230 V AC P.S. G38910052230 Profibus DP slave gateway, 12 Mbaud, 128 I/O, PNO certified 115-230 V AC P.S. G38910120230 Ch.G., 112 Analink signals, Real time Clock, 1 DO NPN < 35 115-230 V AC P.S. G38900014230 V DC, Liquid Crystal Display, Printer port, Modbus port 20-30 V DC P.S. G38900014800 24 V AC P.S. G34205501024 115 V AC P.S. G34205501115 230 V AC P.S. G34205501230 10-30 V AC P.S. G34205501800 24 V AC P.S. G34205502024 115 V AC P.S. G34205502115 230 V AC P.S. G34205502230 Digital Inputs 8 DI, Optoisolated, Contact or NPN G5010 1106 8 DI, Optoisolated, 6-265 V DC/V AC G4420 7401 G8910 2217 G8810 1102 10-30 V AC P.S. G34205502800 8 DI, Volt-free Contacts Dupline P.S. G34105501 1 DI, Contact, Powered through the network Dupline P.S. G50101106 2 DI, Volt-free Contacts Dupline P.S. G50102206 4 DI, Counter <14 kHz, non-volatile memory 230 V AC P.S. G44207401230 15-30 V DC P.S. G44207401724 1 DI, Inductive proximity switch, M18, cable Dupline P.S. G61101145 1 DI, Inductive proximity switch, M18, plug Dupline P.S. G61101145-1 1 DI, Magnetic proximity switch, 11 mm housing Dupline P.S. G89101101 1 DI, Magnetic proximity switch, M14 thread Dupline P.S. G89101101-G 4 DI, Universal switch interface Dupline P.S. G88104401 Passive Infra-red movement detector Dupline P.S. G89101127 2 DI, Water level sensor Dupline P.S. G89102116 2 DI, Smoke detector Dupline P.S. G89102217 1 DI, 90-265 V AC, for external PIR sensor Dupline P.S. G88101102 4 DI, Contact/NPN, Alarm inputs Dupline P.S. G21104401700 8 DI, Contacts, or NPN, designed for elevator control 10-30 V DC P.S. G21205501700 8 DI, Voltage, or PNP, designed for elevator control 10-30 V DC P.S. G21205502700 G2110 4401 G8910 1101 G6110 1145 Price Schedule ‘A7’ G8810 4401 G8910 1127 G8910 2116 NOT APPROVED FOR SIL3 SAFETY APPLICATIONS For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 43 ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system – Components Digital Outputs 1 Description 1 DO, 5 A, SPDT Cat. No. G3430 / G3830 2 DO, 5 A, SPDT 4 DO, 5 A, SPST G3430 5545 4 DO, Relay 16 A, SPST 8 DO, 5 A, SPST 8 DO, 0.7 A, NPN G3430 4249 8 DO, 0.7 A, PNP 8 DO, 16 A/250 V AC, SPST G8830 1143 4 DO, 5 A/250 V AC, with interlocking relay for control of two roller blind motors 1 DO, 13 A/250 V AC, SPST 8 DO, 0.1 A, PNP, designed for elevator control 8 DO, 0.1 A, PNP, designed for elevator control Price $ 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 10-30 V DC P.S. 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S. 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S. 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S. 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 10-30 V DC P.S. 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 10-30 V DC P.S. 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S. Dupline P.S. 10-30 V DC P.S. 10-30 V DC P.S. G34301149024 G34301149115 G34301149230 G34301149800 G34302249024 G34302249115 G34302249230 G34302249824 G34304443024 G34304443115 G34304443230 G34304443824 G34304445024 G34304445115 G34304445230 G38305543024 G38305543115 G38305543230 G38305543824 G34305511024 G34305511115 G34305511230 G34305511800 G34305521024 G34305521115 G34305521230 G34305521800 G34305545024 G34305545115 G34305545230 G34304249024 G34304249115 G34304249230 G34304249824 G88301143 G21305521700 G21305511700 Dupline P.S., or 18-30 V DC P.S. 230 V AC P.S. G42484134724 230 V AC P.S. G34485234230 G34485238230 Dimmer modules 1 Channel, 20-600 Watt, 230 V AC, 6 scenarios/ choices, -ve, or +ve phase angle dimming 1 Channel, 500 Watt, 230 V AC, 4 scenarios/ choices, -ve, or +ve phase angle dimming 2 Channel, 230 Watt, 230 V AC, 4 scenarios/choices 2 Channel, 1-10 V for adjustable ballasts 4 Lighting scenarios per channel G4248 4134 G34485134230 G3448 5234 Price Schedule ‘A4’ 1 - 44 NOT APPROVED FOR SIL3 SAFETY APPLICATIONS For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system – Components Digital Mixed I/O G3440 4443 GH3440 4412 GH6440 4412 Description Cat. No. 2 DI, 2 DO, Combined I/O module, 2 x 6-265 V AC/DC optoisolated inputs and 2 SPST relay outputs G34404443024 24 V AC P.S. 115 V AC P.S. 230 V AC P.S. 15-30 V DC P.S. 2 outputs for control of 3 wire 12 V DC latching valve Highline P.S. and 2 contact inputs GH34850000 2 outputs for control of 3 wire 12 V DC latching valve Highline P.S. and 2 contact inputs GH34850000 4 DI light switch with 4 DO LED indicators, grey Dupline P.S. 4 DI light switch with 4 DO LED indicators, grey Dupline P.S. 4 DI light switch with 4 DO LED indicators, white Dupline P.S. 1 light switch with 1 LED indicator Dupline P.S. 2 light switches with 2 LED indicators Dupline P.S. 3 light switches with 3 LED indicators Dupline P.S. 4 wireless light switches, 4 LED indicators, OPUS, white CR2023 Battery 4 wireless light switches, 4 LED indicators, FUGA, white CR2023 Battery 4 DI, Volt-free Contact, 4 DO, 1.5 mA, PNP, for light switches Dupline P.S. 2 DI, Volt-free Contact, 2 DO, 200 mA, PNP, for elevators 10-30 V DC P.S. 2 DI, Volt-free Contact, 2 DO, 200 mA, NPN, for elevators 10-30 V DC P.S. 4 DI, Volt-free Contact, 4 DO, 200 mA, PNP, for elevators 10-30 V DC P.S. 4 DI, Volt-free Contact, 4 DO, 200 mA, NPN, for elevators 10-30 V DC P.S. Room temperature controller, LC display, OPUS, white Dupline P.S. Room temperature controller, LC display, FUGA, white Dupline P.S. Price $ 1 G34404443115 G34404443230 G34404443824 GH34404412 GH64404412 G81104406 G81104407 G82104406 G85101101 G85102201 G85103301 G82864406703 G81864407703 G88405521 G21404422700 G21404421700 G21405520700 G21405510700 G82452574 G81452574 Irrigation control with Dupline® G8110 By running the power, valve control signals and pulses from flow meters on a single two-wire cable, Dupline reduces the wiring and cable cost significantly and makes expansion easy. Any type of irrigation controller, whether it is a PLC, PC or dedicated controller, can use Dupline as a remote I/O system. In order to achieve sufficient voltage level to switch the 3-wire latching valves in the field, a Booster module converts the Dupline voltage level to 28 V DC. Each valve is connected to an I/O-module with two outputs for opening and closing the valve, and with 2 inputs that can be used for transmission of pulses from flow meters. The module is available in a housing that allows underground installation, and in a DIN-rail mount housing. Each time the valve is fired, a built-in capacitor slowly charges up and after 10s it stores enough energy for the next valve operation. The wiring topology is unrestricted with no limitation in number and length of branches. One Hi-Line network can handle up to 64 valves over distances up to 7 km, and several networks can be linked together. Up to 7 Kilometres! G8210 PLC (optional) Channel generator Hi-Line converter Valve module G8510 Price Schedule ‘A7’ NOT APPROVED FOR SIL3 SAFETY APPLICATIONS For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 45 ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system – Components Analogue modules 1 Description Cat. No. 24 V AC P.S. G34296470024 configurable, Analink, Multiplexed BCD, 8-bit selectable 115 V AC P.S. G34296470115 230 V AC P.S. G34296470230 10-30 V DC P.S. G34296470800 1 AI, 4-20 mA, Analink 8-bit protocol Dupline P.S. G32101161 1 AI, PT100 RTD, 3-wire input, -50 °C to +40 °C Dupline P.S. G32101111 1 AI, PT100 RTD, 3-wire input, +30 °C to +120 °C Dupline P.S. G32101112 1 AI, PT100 RTD, 3-wire input, -10 °C to +100 °C Dupline P.S. G32101113 1 AI, Built in PT1000, +10 °C to +35 °C 2 AI, built in Temperature and Humidity sensors, 0 °C to 50 °C, 5 to 95 % RH Dupline P.S. Dupline P.S. G81112211 G81113315 1 AI, Light intensity sensor, 0.1 to 100,000 lux Dupline P.S. G43111120 1 AI, Temperature sensor, indoor, -30 °C to +60 °C Dupline P.S. G86111010 1 AI, Temperature sensor, IP 67, -30 °C to +60 °C Dupline P.S. G89111010 1 AO, 0-10 V DC, 8 bit resolution 230 V AC P.S. G32385138230 4 AO, isolated, 0-20 mA, 4 - 20 mA, 0-10 V DC, 24 V AC P.S. G34396470024 configurable, Analink, Multiplexed BCD, 8-bit selectable 115 V AC P.S. G34396470115 230 V AC P.S. G34396470230 10-30 V DC P.S. G34396470800 Dupline P.S. G81103394 Landline modem, Digital 8-bit analogue, 24 V AC P.S. G34910040024 non-multiplexed 3 1/2 digit BCD 115 V AC P.S. G34910040115 230 V AC P.S. G34910040230 Optical to Electrical, converting optical to Dupline 230 V AC P.S. G34920000230 Electrical to Optical, converting Dupline to optical 230 V AC P.S. G34930000230 Dupline to Highline converter, 28 V DC irrigation 20-30 V DC GH34850000724 Dupline to signal repeater for signals beyond 10 km 24 V AC P.S. D38920000024 Dupline to signal repeater for signals beyond 10 km 115 V AC P.S. D38920000115 Dupline to signal repeater for signals beyond 10 km 230 V AC P.S. D38920000230 Dupline to Wireless signals @ 868MHz, up to 100 meters 230 V AC P.S. G34860058230 Interface between ESA Text and Touch screens and Powered by GTI50 Dupline channel generators with Modbus RS 485 ports RS 485 port Interface between Carlo Gavazzi EM4 and WM22 energy Dupline P.S. G63910240 Optolink interface, Reads up to 63 Dupline systems 24 V AC P.S. G34910000024 networked through optolinks (G34910000). 115 V AC P.S. G34910000115 Operates with G34910090. 230 V AC P.S. G34910000230 Optolink interface, Links a PC, or a PLC that has an 24 V AC P.S. G34910090024 RS 232 serial port with a fibre optic Lan-ring. 115 V AC P.S. G34910090115 Operates with G34910000 230 V AC P.S. G34910090230 Ethernet to RS 232 converter, 1 port, 10/100, TCP/IP 12 - 48 V DC ETHCONV2 Ethernet to RS 232 converter, 2 port, 10/100, TCP/IP 12 - 48 V DC ETHCONV3 G3210 1161 G3210 1111 G3429 6470 Thermostat, with built-in temp. sensor, -20 °C to +70 °C Converters G3439 6470 G8611 1010 G8911 1010 meters and Dupline G4311 1120 Price Schedule ‘A7’ 1 - 46 Price $ 4 AI, isolated, 0 - 20 mA, 4-20 mA, 0-10 V DC, NOT APPROVED FOR SIL3 SAFETY APPLICATIONS For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included ® Fieldbus Installationbus Refer catalogue CDFB-C I/O Systems - Dupline® field and installation bus system – Components Displays / HMI Description Cat. No. Price $ LED, 4 x 7 segment BCD digits for display of 8-bit analogue 24 V AC P.S. D63696475024 values, with 4 digital outputs 230 V AC P.S. D63696475230 16 channel LED status indicator, panel mounting 24 V AC P.S. G54606606024 115 V AC P.S. G54606606115 230 V AC P.S. G54606606230 Note: Many types of ESA text and touch screens are compatible with Dupline using the Dupline GTI50 interface. D6369 6475 1 Remote controls Infra-red remote control hand-held transmitter for control of lighting, dimming, roller blinds etc... Must be paired with G4185 5531 Infra-Red remote receiver, wall mounted. Must be paired with G4085 5562 G5460 6606 9 Volt battery G40855562 Dupline P.S. G41855531 Programming / testing Coding device for assigning addresses to Dupline I/O 9 V DC battery modules and sensors Test unit for monitoring and control of Dupline channels. 9 V DC battery Not to be used for Hi-Line installions. Test unit for monitoring and control of Hi-Line channels. 9 V DC battery Not to be used for Dupline installations. Coding adaptor between GAP1605 and Dupline modules without a standard connection. Includes an M12 plug for modules like G89111010. GAP1605 GAP1605 GTU8 GHTU8 ADAPT1605 Accessories Power supply, Boosts power to some Dupline modules 15 - 30 V DC P.S. through a third wire DC-bus. Up to 4 ampere @ 25 °C GSM antenna, 900 MHz for G3800xxxx Ch. generators Synchronizer for analogue modules, max of 112 signals Dupline P.S. Cable termination unit for standard Dupline Cable termination unit for Hi-line GTU8 G34850000 ANT1 D32124000 DT01 DT02 Software Software, DDE and ActiveX drivers for G3800 series channel generators and interfaces. Copies and pastes dynamic Dupline links into Excel spreadsheets. Software, Dupline-Online One License for data logging, visualization and alarm handling for G3800xx36 series channel generators Software, ADD-License to Dupline-Online for data logging, visualization and alarm handling for G3800xx36 series channel generators DUPDATACC DUPSERVSW DUPSERVADD G4085 5562 DT01 ADAPT1605 DUPDATACC G4185 5530 Price Schedule ‘A7’ NOT APPROVED FOR SIL3 SAFETY APPLICATIONS For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 47 Operator panels and touch screens SC207 1 3XWPRUHFRQWURO LQ \RXU 3XWPRUHFRQWUROLQ\RXUKDQGV \ U KD KDQ KDQ DQGV GV Features Q Q Q Q Q Q Q 7” Wide 65.536 colors tft 800 X 480 resolution White LED backlighting RS232/RS485 (Integrated MPI) Ethernet USB host and sevice SD/MMC Slot Display SC207 Dimensions Technology 7” LCD Graphic TFT 65.536 colours External (W x H x D) (mm) 202 x 142 x 40 Touch screen Analogue Backlighting White LED Bore holes (W x H) (mm) 194 x 134 Minimum lamp life at 50,000 hours 25° C Technical specifications Chassis Plastic ABS Resolution Power supply 18...32 Vcc 800 x 480 pixel Power consumption ~ 8 W (24 V DC) Processor Intel PXA 270 Hardware clock Supercapacitor 72h CPU Clock 520 MHz Working temperature 0...+50 °C RAM 64 MB Flash 32 MB Interfaces Storage/transport temperature Humidity Serial port SP1 (RS232/485/MPI) Weight USB Host port 1 x v 1.1 Protection level IP 65 front USB Device port 1 x v 1.1 Certification CE Card Bus Slot Secure Digital/MMC Network Ethernet 10/100 Mbit - RJ45 Terminal -20...+60 °C 85% (non-condensing) ~ 1,6 Kg Description Cat. No. 7" widescreen 65k colours TFT, Port: SP1, Ethernet, USB:Host device, SD/MMC slot SC207A0101 SC207 Drivers available Q Q Q Q Q Q Q Q Allen-Bradley (ETH), MicroLogix, DF1 Delta DVP Hitachi Mitsubishi A-Fx-Fx2 Modbus RTU Master and Slave Modbus TCP Master and Slave (ETH) Omron Host Link, CJ1-CS1-CP1, CS1-CJ1 (ETH) Panasonic FP-Sigma series (RS 232), FP series (ETH) Schneider Twido-Zelio-Unitelway, Premium (ETH) Siemens S5, S7-200 PPI, S7 300/400 (ETH), Q Q 63 565603, 3/&GHYLFHV 3/& 1 - 48 :HE6HUYHU ,77HUPLQDO ;6,3& 3ULQWHU (7+(51(7 6/27 6HFXUH'LJLWDO 00& &R'H6\V 3ULQWHU 86% 86%SHQGULYH 2IÀFH3& ,3FDPHUDV ,QWHUQHW For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Operator panels and touch screens - System Overview Q Q Q Q Fast and easy configuration Extensive product range Large displays - up to 12.1” IP 65 protection lever (front) Serial and network communications Dual serial ports allow simultaneous communications to different front-end devices, while pipelining expands the functionality of the panel into a gateway by providing bi-directional data transfer between disparate devices. Alarms, reports and mimic pages can be sent directly to a parallel printer by panels fitted with an on-board centronics port. VT 170 W / VT 190 W / VT 300 W VT 310 W / VT 320 W / VT 330 W VT 555 W / VT 565 W / VT 575 W VT 585 W / VT 595 W 1 PC (programming) Drives MSP RS 232 RS 422/485/TTY ASP RS 232/RS 485 LPT PLCs Printer (not VT 170 W) ESANet ESANet is a high-speed network that allows both the text and graphical panels to communicate and share data with each other. Up to 32 ESA panels can be configured in a client server architecture. Server panels connect to I/O devices such as a PLC, while clients use variables and memory areas exported by the server. Using one of the standard serial ports on each panel, units can be linked together to provide remote monitoring and control from all areas of the factory or process. PC (programming) CONTROL NETWORK MSP ASP ESANET (32 UNITS – Available on all the panels) LPT Communication drivers The VT range of panels will directly communicate with an extensive range of I/O devices including PLCs and drives. Standard interfaces include: ABB, Allen Bradley, Crouzet, GE-Fanuc, Hitachi, Idec, Izumi, Keyence, Klockner Moeller, LG, Matsushita / NAIS, NHP Microlink, Mitsubishi, Modicon, Omron, SAIA, Siemens, Sprecher + Schuh, Telemecanique, Toshiba. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 49 Refer publications VT50, VT170 Operator panels and touch screens Text based operator panels The ESA range of text and graphic operator panels comprises three groups of models – text panels, graphical touch panels and graphical touch screens. Each model, with its own array of features, is targeted towards specific applications and user requirements. 1 Q Flexible serial and network connectivity Q One software package for all models Q Robust die-cast construction Q Full range of interface drivers Q Fast and easy configuration Q Extensive product range Q Large displays - up to 12.1” Q IP 65 protection level (front) Text operator panels The compact range of text only displays is ideal for machine control in small to medium sized applications. With bright LCD back-lit displays available in either a 2 x 20 character or 4 x 20 character configuration and an optional printer port, these text displays offer extreme flexibility at a cost price. VT 050 Thanks to the availability of a large number of serial protocols, these terminals can be connected to PLCs, variable speed drives, thermoregulators and other serial devices. Ordering details Text operator panels (dimensions in mm) Cat. No. Text, LCD, 4 x 20, Dim. 166 x 86 x 41, MSP 1) VT060 Text, LCD, 4 x 20, Dim. 148 x 188 x 41, MSP 1) VT150W Text, LCD, 4 x 20, Dim. 148 x 188 x 41, MSP ), PROFIBUS DP VT150W DP Text, LCD, 4 x 20, Dim. 296 x 188 x 42, MSP 1) VT160W Text, LCD, 4 x 20, Dim. 296 x 188 x 42, MSP ), PROFIBUS DP VT160W DP Text, LCD, 4 x 20, Dim. 126 x 196 x 60, MSP 1), ASP 2) VT170W A Text, LCD, 4 x 40, Dim. 252 x 196 x 60, MSP ), ASP ) VT190W A Text, LCD, 4 x 40, Dim. 252 x 196 x 60, MSP 1), ASP 2), LPT VT190W AP VT050 1 VT 170WA Price $ Description Text, LCD, 2 x 20, Dim. 166 x 86 x 41, MSP 1) 1 1 2 Accessories Mounting brackets and screws, rubber gasket, phoenix connector RVT5009 (VT 050, VT 060) VT 190W A Lithium 3 V battery back-up recipe and clock VTBUTTONCELL External gateway to connect a PC (SCADA, MS Excel, MS Access, PCNET Internet Explorer, etc.) to any PLC or ESA operator panel RS 485 module to connect the terminal in an ESANET Network VT5ESABUS (to use the VT 170 WA / VT 190 WA in a server configuration) VTPROFI/DP External module PROFIBUS / DP External 24 V DC 3.5 A Power supply ) XCSP85C Programme CD software and cable 4) VTWINLITE 3 Notes: ) ) 3 ) 4 ) 1 2 Multi serial port (25 pin). Auxiliary serial port (15 pin). XCSF85C power supplies are on Price Schedule ‘A2’. NETT price only. Price Schedule ‘A4’ 1 - 50 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer publications VT32-F Operator panels and touch screens Graphics operator panels This range of graphic based touch panels is ideal for replacing pushbuttons, indicating lights, analogue meters and much more. Starting at the compact 5” display the units are available in colour or monochrome, STN or TFT graphics. Dual serial ports, optional printer port, trending, recipe management and lifelike graphics make these units ideal for any size applications. Easy to configure and simple to use. Thanks to the availability of a large number of serial protocols, these terminals can be connected to PLCs, variable speed drives, thermoregulators and other serial devices. 1 Ordering details Graphic operator panels (dimensions in mm) Description Cat. No. Graphic, Monochrome STN, Res 240 x 64, VT300W A Price $ Dim. 252 x 196 x 60, MSP 1), ASP 2) Graphic, Monochrome STN, Res 240 x 64, VT300W AP Dim. 252 x 196 x 60, MSP 1), ASP 2), LPT VT 310W A Graphic 5.5” screen, Monochrome STN, Res 240 x 128, VT310W A Dim. 252 x 196 x 60, MSP 1), ASP 2) Graphic 5.5” screen, Monochrome STN, Res 240 x 128, VT310W AP Dim. 252 x 196 x 60, MSP 1), ASP 2), LPT Graphic 5.7” screen, Colour STN, Res 320 x 240, VT320W A Dim. 305 x 196 x 60, MSP 1), ASP 2) Graphic 5.7” screen, Colour STN, Res 320 x 240, VT320W AP Dim 305 x 196 x 60, MSP 1), ASP 2), LPT VT 320W A Graphic 10.4” screen, Monochrome STN, Res 640 x 480, VT330W APM Dim 435 x 260 x 74, MSP 1), ASP 2), LPT Graphic 10.4” screen, Colour TFT, Res 640 x 480, VT330W APT Dim 435 x 260 x 74, MSP 1), ASP 2), LPT VT 330W APM Accessories Cat. No. Lithium 3 V battery back-up recipe and clock VTBUTTONCELL External gateway to connect a PC (SCADA, MS Excel, MS Access, PCNET Price $ Internet Explorer, etc.) to any PLC or ESA operator panel VTPROFI/DP External module PROFIBUS / DP External 24 V DC, 3.5 A Power supply ) XCSP85C Programme CD software and cable 4) VTWINLITE 3 Notes: ) ) 3 ) 4 ) 1 2 Price Schedule ‘A4’ Multi serial port (25 pin). Auxiliary serial port (15 pin). XCSF85C power supplies are on Price Schedule ‘A2’. NETT price only. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 51 Operator panels and touch screens Refer publications VT155-F, VT525-F, VT555-F Graphics touch screens 1 VT 155W This range of graphic based touch screens is ideal for replacing pushbuttons, indicating lights, analogue meters and much more. With a large display of up to 10.4”, the units are available in colour or monochrome, STN or TFT graphics. Dual serial ports, optional printer port, trending, recipe management and lifelike graphics make these units ideal for any size applications. Easy to configure and simple to use. Thanks to the availability of a large number of serial protocols, these terminals can be connected to PLCs, variable speed drives, thermoregulators and other serial devices. Ordering details Graphic touch screens (dimensions in mm) Description VT 185W VT 555W VT 505W VT 505H VT 515W VT 525W Graphic 4" screen, 4 Tones of grey LCD, Res 240 x 128, Dim 166 x 100 x 40, MSP 1), ASP-8 2), Project: 640 KB - Recipes: 16 KB Graphic 4" screen, 4 Tones of grey LCD, Res 240 x 128, Dim 166 x 100 x 40, ASP-8 2), Project: 640 KB - Recipes: 16 KB, Profibus DP Graphic 4" screen, 4 Tones of grey LCD, Res 240 x 128, Dim 166 x 100 x 40, ASP-8 2), Project: 640 KB - Recipes: 16 KB, Ethernet 10/100 Graphic 3.6" screen, 16 Colour TFT, Res 320 x 240, Dim 166 x 100 x 40, MSP 1), ASP-8 2), Project: 960 KB - Recipes: 32 KB Graphic 3.6" screen, 16 Colour TFT, Res 320 x 240, Dim 166 x 100 x 40, ASP-8 2), Project: 960 KB - Recipes: 32 KB, Ethernet 10/100 Graphic 5.5" screen, Monochrome STN, Res 240 x 128, Dim 210 x 158 x 54, MSP 1), ASP 3), 512 KB - Recipes: 128 KB, Ethernet 10/100 Graphic 5.5" screen, Monochrome STN, Res 240 x 128, Dim 210 x 158 x 54, MSP 1), ASP 3), LPT, 512 KB - Recipes: 128 KB Graphic 5.5" screen, Monochrome STN, Res 240 x 128, Dim 210 x 158 x 54, MSP 1), LPT, 512 KB - Recipes: 128 KB, Profibus DP Graphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), Project: 640 KB - Recipes: 16 KB Graphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), Project: 640 KB - Recipes: 16 KB, Profibus DP Graphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, ASP-8 2), Project: 640 KB - Recipes: 16 KB, Ethernet 10/100 Hand held Graphic 5.7" screen, 4 level blue STN, Res 320 x 240, 10 function keys, 2 push buttons, optional MSP 1) if VTHCB adaptor fitted, Project: 640 KB - Recipes: 16 KB Graphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), Project: 640 KB - Recipes: 16 KB, 8 KB Memory Alarms, capacitor back-up Graphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), Project: 640 KB - Recipes: 16 KB, 8 KB Memory Alarms, Capacitor back-up, Profibus DP Graphic 5.7" screen, 4 level blue STN, Res 320 x 240, Dim 210 x 158 x 54, ASP-8 2), Project: 640 KB - Recipes: 16 KB, 8 KB Memory Alarms, Capacitor back-up, Ethernet 10/100 Graphic 5.7" screen, 16 Colour STN, Res 320 x 240, Dim 210 x 158 x 54, MSP 1), ASP-8 2), Project: 960 KB - Recipes: 32 KB Graphic 5.7" screen, 16 Colour STN, Res 320 x 240, Dim 210 x 158 x 54, ASP-8 2), Project: 960 KB - Recipes: 32 KB, Profibus DP Graphic 5.7" screen, 16 Colour STN, Res 320 x 240, Dim 210 x 158 x 54, ASP-8 2), Project: 960 KB - Recipes: 32 KB, Ethernet 10/100 Hand held Graphic 5.7" screen, 16 Colour STN, Res 320 x 240, 10 function keys, 2 push buttons, optional MSP 1) and ASP-8 2) if VTHCB fitted, Project: 960 KB - Recipes: 32 KB Notes: Cat. No. Price $ VT155W VT155W 000DP VT155W 000ET VT185W VT185W 000ET VT555W A VT555W AP VT555W AP0DP VT505W VT505W DP VT505W 000ET VT505H VT515W VT515W 000DP VT515W 000ET VT525W VT525W 000DP VT525W 000ET VT525H ) Multi Serial Port (25 pin). ) Auxiliary Serial Port (8 pin). 3 ) Auxiliary Serial Port (15 pin). 1 2 Price Schedule ‘A4’ 1 - 52 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer publications VT575-F, VT595-F, Operator panels and touch screens Graphics touch screens Ordering details Graphic touch screens (dimensions in mm) Description Cat. No. Graphic 5.7" screen, 16 Colours STN, Res 320 x 240, Dim 210 x 158 x 61, VT560W A Price $ 1 MSP 1), ASP 2), Project: 1 MB - Recipes: 128 KB, Battery back-up Graphic 5.7" screen, 8 tones of blue STN, Res 320 x 240, Dim 210 x 158 x 61, VT560W A0M MSP 1), ASP 2), Project: 1 MB - Recipes: 128 KB, Battery back-up VT 560W Graphic 5.7" screen, Colour STN, Res 320 x 240, VT565W A Dim 210 x 158 x 54, MSP 1), ASP 2) Graphic 5.7" screen, Colour STN, Res 320 x 240, VT565W AP Dim 210 x 158 x 54, MSP 1), ASP 2), LPT, Graphic 5.7" screen, Monochrome STN, Res 320 x 240, VT565W A0M Dim 210 x 158 x 54, MSP 1), ASP 2) Graphic 5.7" screen, Monochrome STN, Res 320 x 240, VT565W APM Dim 210 x 158 x 54, MSP 1), ASP 2), LPT, VT 565W Graphic 8.4" screen, 256 Colours TFT, Res 800 x 600, Dim 246 x 189 x 38, VT580W APT MSP 1), ASP 2), LPT, Project: 7 MB - Recipes: 192 KB Graphic 8.4" screen, 256 Colours TFT, Res 800 x 600, Dim 246 x 189 x 38, VT580W 0PTDP MSP 1), LPT, Project: 7 MB - Recipes: 192 KB, Profibus DP Graphic 8.4" screen, 256 Colours TFT, Res 800 x 600, Dim 246 x 189 x 38, VT580W 0PTET MSP 1), LPT, Project: 7 MB - Recipes: 192 KB, Ethernet 10/100 Graphic 10.4" screen, Colour TFT, Res 640 x 480, Dim 336 x 256 x 44, VT 575W VT585W BPT MSP 1), ASP 2), LPT, Project: 7 MB - Recipes: 128 KB Graphic 10.4" screen, Colour TFT, Res 640 x 480, Dim 336 x 256 x 44, VT585W BPTDP MSP 1), LPT, Project: 7 MB - Recipes: 128 KB, Profibus DP Graphic 10.4" screen, Colour TFT, Res 640 x 480, Dim 336 x 256 x 44, VT585W BPTET MSP 1), LPT, Project: 7 MB - Recipes: 128 KB, Ethernet 10/100 Graphic 12.1" screen, 256 Colour TFT, Res 800 x 600, Dim 336 x 256 x 44, VT595W APT MSP 1), ASP 2), LPT, Project: 7 MB - Recipes: 128 KB Graphic 12.1" screen, 256 Colour TFT, Res 800 x 600, Dim 336 x 256 x 44, VT 580W VT595W 0PTDP MSP 1), LPT, Project: 7 MB - Recipes: 128 KB, Profibus DP Graphic 12.1" screen, 256 Colour TFT, Res 800 x 600, Dim 336 x 256 x 44, VT595W 0PTET MSP 1), LPT, Project: 7 MB - Recipes: 128 KB, Ethernet 10/100 VT 585W VT 595W Notes: ) Multi Serial Port (25 pin). ) Auxiliary Serial Port (15 pin). 1 2 Price Schedule ‘A4’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 53 Operator panels and touch screens Communication cables 1 Description Cat. No. Download cable from PC to ESA displays VTCBLXFR ) ESA MINI DIN download adaptor VTCBLADP 1) Communications cable between the 9 pin ASP port CBL90H 1) Price $ 1 (VT 170 / VT 190 ) and the Hitachi H Board, H 200 / H 250 / H 252 B / H 252 C PLCs (Can also be used to program the above PLCs) Communications cable between the 25 pin MSP port (all ESA panels) VTCBL2515 1) and the Hitachi H Board, H 200 / H 250 / H 252 B / H 252 C PLCs Communications cable between the 9 pin ASP (VT 170 / VT 190 ) CBL1509 1) and the Hitachi EH-150 PLC (Can also be used to program the EH-150 PLC) Communications cable between the 25 pin MSP port (all ESA panels) VTCBL2545 1) and the Hitachi EH-150 PLC Accessories Lithium 3 V battery back-up recipe and clock VTBUTTONCELL Transparent adhesive protection film for 6” touch screen PROTFILM6 (VT505W, VT525W, VT555W, VT565W) 5 sheets included Transparent adhesive protection film for 10” touch screen PROTFILM10 (VT585W) 5 sheets included Transparent adhesive protection film for 12” touch screen (VT595W) PROTFILM12 5 sheets included External gateway to connect a PC (SCADA, MS Excel, MS Access, PCNET Internet Explorer, etc.) to any PLC or ESA operator panel VTPROFI/DP External module PROFIBUS / DP External 24 V DC 3.5 A Power supply 2) XCSP85C Programme CD software and cable ) VTWINLITE 3 Notes: ) All cables are 2 m in length. ) XCSF85C power supplies are on Price Schedule ‘A2’. 3 ) NETT price only. 1 2 Price Schedule ‘A4’ 1 - 54 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Operator panels and touch screens VTWIN Configuration software One software package for the entire range All graphic and text based panels are configured with one package - VTWIN. VTWIN is the Microsoft Windows® based software for configuring your operator panel. The software supports Windows 95, Windows 98, Windows NT 4.0, Windows 2000 and Windows XP. It is intuitive, easy to use and includes a graphics editor for developing professional looking screens with a minimum of fuss. The software comes packaged with all available communication drivers and a cable for communication between a PC and the panel. On-line help and the ability to import bitmap images make configuration quick and easy, saving both time and money. 1 Use the same software development environment to configure all of the operator units, whether it is the low-end text based panels or the high-end graphics based touch panels. Application programs previously created for one particular model can be re-used for any model in the range. This means you only need to learn one software package and importantly, you only need to purchase one software package. VTWIN features Q Q Q Q Q Rapid application development – a wide variety of pre-configured picture elements can be inserted into a page – multi-language labels and texts, dynamic text fields, lines, rectangles, ellipses, arcs, bar graphs, touch buttons, bitmap images, information messages, alarms, etc Graphic image formats – directly import graphic images from a wide selection of standard formats e.g. BMP, JPG, GIF, DXF, PSD, TIFF, WMF and many more 3-D Graphics – create life-like 3-D graphic pictures with image compression, stretching, dithering and support for 256 colours Alarm thresholds – specify alarm thresholds on objects making it possible to dynamically change colours based on the related process variable Advanced graphics functions – represent analogue values using analogue indicators, selector knobs, potentiometers and sliders With the WYSIWYG graphics editor you know exactly how your text and graphics will appear on the VT terminal before you download the project. To gain access to PLC data simply assign a variable name and the required PLC register. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 55 Operator panels and touch screens Dimensions and cut-outs (mm) 1 Text and Graphic panels 27 139 252 196 86 166 242 232 29 186 95 178 120 4.5 29 116 41 116 5 5 77 157 60 VT 190W VT 170W VT 50/ VT 60 435 196 260 305 291 275 60 418.3 403 5 5 4.5 28 55 249 240 120 186 176 130 ø5 ø 4.5 55 28 74 8 137.5 VT 320W 1 - 56 137.5 152.5 49 7.6 152.5 49 VT 330W For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Operator panels and touch screens Dimensions and cut-outs (mm) Touch Operator panels 1 VT 155W / VT 185 VT 505W/VT 555W/VT 565W VT 575W / VT 580 VT 585W For further information please contact Sales 1300 NHP NHP or visit nhp.com.au VT 595W GST not included 1 - 57 WORLD CLASS SCADA / HMI SOFTWARE AUTOMATION SYSTEMS Smart UI (web enabled) PLCs RTUs Databases MES Classic UI OPC Client OPC Server API Databases Web Services Web Services AC-ADROIT-SCADA HMI r 0OMJOFDPOGJHVSBUJPO r %#DPOOFDUJWJUZ0%#$BOE0-&%# r "DUJWFDMVTUFSTTFSWFSSFEVOEBODZ r %ZOBNJDTFDVSJUZ r # VJMUJODIBOHFNBOBHFNFOU BOEBVEJUTZTUFN 1300 NHP NHP nhp.com.au r *OUFHSBUFESFDJQFNBOBHFNFOU r 4.4IBOEMJOHTZTUFN r "EWBODFEBMBSNJOHTZTUFN r 0 QFOTZTUFNDPOOFDUJWJUZ $0.%$0.0-&0-&%#01$42- $47JNQPSUFYQPSU 0800 NHP NHP nhp-nz.com Visualisation and reporting software World class 32 bit SCADA / HMI software Open automation technology Adroit is a technologically advanced 32 bit SCADA (Supervisory Control and Data Acquisition) system designed for process control, manufacturing systems and open automation applications Developed specifically for Windows 2000, XP, and 2003 Server, Adroit has a flexible object-oriented client server architecture that supports from a standalone implementation to an installation spanning multiple sites. 1 Outstanding features Q Q Q Q Q Q Q Q Q Q Alarm Management SMS Handling System System Auditing Plant VCR - replay historical data using mimics Database connectivity - connect to any third-party ODBC and OLE DB database Active clusters - Adroit’s elegant answer to Hot stand-by and Server redundancy Web client - view plant data from anywhere in the world Visual basic and java scripting - built-in scripts require no proprietary code OPC client and server 150 + native drivers Microsoft Technologies ® Adroit Client • On-line configuration • No separate development system • Mimic replay • Template mimics and trends Adroit Client Remote Adroit Client Internet Ethernet/ICP/IP • Scalable open server architecture • Integrated Visual Basic scripting • Wide area network support • SQL database connectivity Control Network Adroit SCADA Server Adroit SCADA Server Adroit SCADA Server Modem Active Cluster Hot Stand-By Programmable logic controllers (PLCs), databases, remote terminal units (RTUs), OPC servers Distributed multi-client multi-server configuration in a large network system with several servers and several clients, each running on separate Windows 32 bit operating system. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 59 Visualisation and reporting software World class 32 bit SCADA / HMI software 1 Server Redundancy with Active clusters Very few commercial off-the-shelf SCADA HMI products offer genuine hot-standby redundancy, whereby a computer running the real-time, tag database, can suffer catastrophic hardware or software failure without causing loss of data or operator control and monitoring capability. Now with the release of Adroit with its Active Clustering technology this most demanding of all requirements is now achievable. The above diagram shows 5 Adroit workstations, 2 Adroit servers, and some PLCs connected in a typical client-server, hot-standby configuration. To achieve 100 % redundancy and bumpless switch-over of workstations from a failed server to a standby server, both servers need to be running exactly the same tag database. Server I/O options allow for replicated scanning in and/or out, when in standby mode. Alternatively, if the PLC or other front-end device does not support more than one port, or, as is often the case, PLC communications bandwidth is the critical system bottleneck, then automatic shadowing of plant I/O will occur. Open Interfaces and Drivers Adroit has a comprehensive range of drivers for all major controllers and networks including: Q OPC Client and Server Q Texas Instruments Q Moore Q DNP3 Q ABB Q Eagle Q Hitachi Q Toshiba Q Lonworks Q Siemens Q Microlink Q Gem 80 Q Allen Bradley Q Opto 22 Q Motorola Q Modbus Q Samsung Q Square D Q Omron Q Yokogawa Q Klockner Moeller Q Mitsubishi Q Applicom More than 150 drivers available…visit www.nhp.com.au/p_automation_communication.asp for complete driver list. 1 - 60 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Visualisation and reporting software World class 32 bit SCADA / HMI software Plant VCR Plant VCR is essentially a more graphical alternative to historical trends. One may wish to traverse through the historical values of tags using existing pictures to diagnose and analyse plant conditions as they happened. Plant VCR can be thought of as a third mode for pictures, namely, editing, viewing (real time) and viewing (historical). The historical picture can be played backwards or forwards VCR style using the tag’s historical values at a configured speed, or one ‘freezed frame’ at a time in either direction. There is no configuration required to enable the operation of plant VCR for any existing or new picture in Adroit. However, all the tags in the picture that require historical playback need to be data logged. 1 Scripting Scripting is essentially user-coded routines that will run concurrently with the Adroit software. With these routines the user has the facility to manipulate agent data, manage User interface (UI) operations, control third-party data interfacing (via COM and OLE), automate complex tasks, perform mathematical operations and manage the look and feel of the Adroit application. Adroit scripting is developed in the following area: Script agent: greater control of agent server data through powerful mathematical and conditional scripting. Scripts execute at set time intervals or on change of data. Scripts are edited with an editor and debugger having colour syntax highlighting, script tips (VBA style syntax assistance) and a dialogue editor. A Microsoft™ script engine has been incorporated into Adroit thereby allowing integrators and end users to develop script in VB or Java. In addition to selecting which subroutine within the script is executed, separate initialisation and clean up subroutines can also be optionally configured. DB connectivity OLE DB has been brought into Adroit to give tight, bi-directional data transfer of both real-time and historical data between Adroit and third-party databases. These databases may exist locally or remotely on a LAN/WAN. Data transfer will execute on data change and/or at configurable time intervals. The nice thing about the Adroit DB connectivity is that Adroit will act as a database client. Third-party gateway software applications are no longer needed. The dbAccess agent also support ODBC allowing values to be written to or read from any ODBC source including CSV files. Both OLE DB and ODBC allow values to be appended, deleted, updated or retrieved. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 61 Visualisation and reporting software World class 32 bit SCADA / HMI software 1 Graphics In days gone by, plant mimics were built using archaic bitmap techniques. Users came to accept the inherent restrictions imposed by these methods. There was no other choice. A few years ago Adroit changed it all. Since then users have been creating concise process graphics with the on-line vector-based drawing tools available in Adroit - mimics that automatically size to the display resolution to give crisp, clear images. Images that do not pixelate when sized, images made so life-like with 3D shading that it becomes difficult to distinguish the mimic from a photo. That’s the power of Adroit. Open systems connectivity This key feature provides an open platform through which third-party applications communicate with Adroit. The OLE automation function together with the command set available in the automation interface allows for powerful data retrieval and manipulation that can easily be used for process monitoring, control, reporting, QA control and data archiving. In fact the scope of the automation interface is such that the complete configuration of an Adroit agent database is possible via an external package; – thereby bypassing the built-in agent configurator, – allowing for rapid, rules-based tag generating. Logging Efficient data logging and recall where disk space is optimised is old hat to Adroit (in Adroit the exception-based logging function only logs a value if it changes by more than a user-set amount – if a value does not change it is not logged. This leads to an efficient utilisation of disk space but not to “holes” in the log files, as Adroit has the built-in intelligence to recreate a complete set of time-based records at any time). Adroit has however taken its already highly efficient functions of data logging and data recall to yet another level of optimisation and flexibility, with increased data throughput and programme responsiveness when logging to huge databases. And now you can also log to named files, log on demand at any time, establish multiple logging rates per tag and have greater integrity with the log file systems. With Adroit’s OLE DB connectivity you can now log directly to any third-party database (SQL, MS ACCESS, ORACLE, ETC.) 1 - 62 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Visualisation and reporting software World class 32 bit SCADA / HMI software Trending So you want to see how the temperature has changed over the last year, but still want to maintain realtime trending? With its built-in capability of trending up to eight variables per trend window, and letting the operator scroll from realtime to historical and back to realtime using the keyboard or mouse, Adroit offers a complete trending package. That’s the trend in Adroit – always way ahead of the rest. Adroit’s multi-colour trends dynamically change colour based on the alarm condition of the trend variable, while bookmarks allow you to insert notes into your trend. 1 Recipes Recipes provide an easy way to download process parameters to front-end devices, to automate routine tasks, and for constructing process simulations. In Adroit, recipes are made up of two components: a Master recipe and one or more associated control recipes. The Master recipe contains the ingredients to be used and the sequence that they will be downloaded, while the control recipe specifies the quantities the ingredients take on. Although essentially sequential in nature, Adroit recipes have the built-in capability to react to unexpected process deviations by executing process-related conditional branching instructions. A very high degree of process safety can therefore be achieved when using Adroit recipes. Alarming Alarms are events that need to be brought to the attention of the operator for action. Unfortunately most SCADA applications are over-alarmed where everything is alarmed in case it is needed. The result: a flood of meaningless alarms that the operator eventually starts ignoring. Can this happen with Adroit? No! Because Adroit provides a structure for configuring alarms that immediately allows for intelligent alarming practices. For example, groups of alarms can be disabled automatically by an internal or external event, alarms can be dynamically routed to various peripheral devices (mobile phones, pagers etc.) depending on process conditions, alarms can be globally acknowledged, and more. And above all, hierarchical alarm management scenarios are easy to setup and manage. That’s the power of Adroit. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 63 Visualisation and reporting software World class 32 bit SCADA / HMI software 1 Alarm Management Alarm Management is an important aspect of process control required to counteract inefficient alarming. Alarm management allows you to create an alarming system that alerts the operator to the most relevant alarm for the current incident. In this case fewer alarms are more effective as the human mind can only focus on a few things at a time. The Alarm Management agent logs all incidents and their details, including their time of occurrence, their time of acknowledgement and the time at which they were cleared to a database. This repository of incidents then allows you to: Q Generate statistics from the data produced by the alarming system. This allows you to have efficient and meaningful incident reviews to identify and remove nuisance alarms by analysing the counts, frequencies, durations and acknowledgement times of alarms. Q Measure KPIs to improve your alarming configuration. Built-in Auditing Agent Server Auditing allows logging of the Agent Server’s sessions and selected activities performed during these sessions to an OLE DB database. In addition, by using the Audit Agent you can log the changes of values that are important to the running of your process, such as set point values and/or alarm limits. Generally, you will audit the Agent Server to provide a means of recourse in the event of a problem occurring to your process. Examining the audit logs you can determine any of the following user actions: Q When the Agent Server was stopped and started; Q What agents have been added or removed from your Adroit installation; Q What Adroit documents have been saved; Q Which audited tags (as specified in the Audit agent) have changed in value; Q Who the logged on user was, when these audited events occurred. SMS Handling System The Command agent can send and receive SMS messages by using a device of the GSM_SMS protocol driver. It uses the GSM_SMS driver, which sole function is the sending and receiving of SMS messages to and from GSM modems. The Command agent provides the following functionality: Q Ability to both send and receive SMS messages of up to the full 160 character SMS message limit; Q Send SMS messages to a single recipient, manually, programmatically or automatically to remotely monitor the status of important process values; Q Monitoring of the sent SMS messages for auditing purposes. Q Sending a message to a different mobile number if no response is received within a specified period; Q Receive SMS messages from one or more mobile phones, and if necessary, perform commands to remotely supervise and control your process and configure Adroit (acknowledging alarms or fetching or setting process values etc.); Q Ability to configure pseudonyms and macros to simplify the process of specifying commands by providing shorter aliases for the names of commonly referenced tags. 1 - 64 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Visualisation and reporting software Adroit SCADA Ordering instructions Adroit is a modular system that is made up of 1 or more Servers and remote clients if required. The following steps will help guide you through the process of selecting the components required for an Adroit SCADA system 1 Step 1 – Select the Adroit SCADA Server Select the Adroit SCADA Server Option you require. This is based on the number of external variables (Scan Points) you need to read or write to an external device. Internal variables 1) are not counted as part of the licence. Adroit Primary Server Step 2 (Optional) - Adroit SCADA Active Cluster (Redundant) Server if required If your application requires the additional security of a backup server which will retain all of your data and enable you to continue to monitor and control your plant in the event of a failure of the server, then select an Adroit SCADA Active Cluster Server. The Active Cluster Server must match the Primary Server in terms of the number of Scan Points. Example: If you have selected a 750 Scan Point Primary Server, you must select the 750 Scan Point Active Cluster Server. Adroit Primary Server Adroit Active Cluster Server Step 3 (Optional) – Adroit SCADA Remote Clients if required Both the Adroit SCADA Server and Adroit SCADA Active Cluster Server include a User Interface which means that Adroit Client Adroit Client Adroit Client they can both be used as an operation station. If, however, you require additional User Interfaces that are either located in a remote location from the Servers or would like to reduce the load on the servers by running them as dedicated servers, then Adroit Primary Adroit Active select the Adroit SCADA Remote Client licence that matches Server Cluster Server your Server. Example: If you have selected a 150 Scan Point Adroit SCADA Server, then you must select 1 or more Adroit SCADA Remote Clients for 150 Scan Point Server. Upgrades If you already have an Adroit SCADA system and would like to upgrade to the latest version of Adroit or increase the size or your system, please contact NHP as the cost of the upgrade depends both on the version you are upgrading from and the system configuration, in terms of the number of scan points, the number of clients and whether your system has a redundant server pair (active cluster). Adroit Technology Agreement An alternative method of keeping your system up-to-date is via the Adroit Technology agreement. The agreement lasts for 12 months and entitles you to any new versions of Adroit that are released within the 12 months following the agreement start date. As for upgrades, please contact NHP if you wish to purchase a technology agreement. Please note that the Adroit Technology agreement provides a more cost effective method of keeping your Adroit SCADA software up-to-date with a built-in discount over standard upgrades. Note: ) Internal Variables are variables which do not read or write data to or from an external device or software package. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 65 Visualisation and reporting software Adroit SCADA SCADA Software Ordering details 1 Adroit SCADA Server Options (Step 1) Description Cat. No. 30 Scan Point ) Server and User Interface ADROIT30SI 75 Scan Point 1) Server and User Interface ADROIT75SI 150 Scan Point ) Server and User Interface ADROIT150SI 300 Scan Point 1) Server and User Interface ADROIT300SI 750 Scan Point ) Server and User Interface ADROIT750SI 1500 Scan Point 1) Server and User Interface ADROIT1500SI 2500 Scan Point ) Server and User Interface ADROIT2500SI 5000 Scan Point 1) Server and User Interface ADROIT5000SI 25000 Scan Point ) Server and User Interface ADROIT25000SI Unlimited Scan Point 1) Server and User Interface ADROITULSI 1 Adroit Server Adroit Stand-alone Server 1 1 1 1 Price $ Adroit SCADA Active Cluster (Redundant) Server Options (Step 2 – optional) 30 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface ADROIT30SI-A 75 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface ADROIT75SI-A 150 Scan Point ) Active Cluster ) (Redundant) Server & User Interface ADROIT150SI-A 300 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface ADROIT300SI-A 750 Scan Point ) Active Cluster ) (Redundant) Server & User Interface ADROIT750SI-A 1500 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface ADROIT1500SI-A 2500 Scan Point ) Active Cluster ) (Redundant) Server & User Interface ADROIT2500SI-A 5000 Scan Point 1) Active Cluster 2) (Redundant) Server & User Interface ADROIT5000SI-A 25000 Scan Point ) Active Cluster ) (Redundant) Server & User Interface ADROIT25000SI-A Unlimited Scan Point 1) Active Cluster 2) (Redundant) Server & ADROITULSI-A 1 2 1 Adroit Server Adroit Server Adroit Active Cluster (Redundant) Server 2 1 2 1 2 User Interface Adroit SCADA Remote Client Options (Step 3 – optional) Remote Client (User Interface) for 30 Scan Point 1) Server ADROIT30RC Remote Client (User Interface) for 75 Scan Point ) Server ADROIT75RC Remote Client (User Interface) for 150 Scan Point 1) Server ADROIT150RC Remote Client (User Interface) for 300 Scan Point ) Server ADROIT300RC Remote Client (User Interface) for 750 Scan Point 1) Server ADROIT750RC Remote Client (User Interface) for 1500 Scan Point ) Server ADROIT1500RC Remote Client (User Interface) for 2500 Scan Point 1) Server ADROIT2500RC Remote Client (User Interface) for 5000 Scan Point ) Server ADROIT5000RC Remote Client (User Interface) for 25000 Scan Point 1) Server ADROIT25000RC Remote Client (User Interface) for Unlimited Scan Point ) Server ADROITULRC 1 Adroit Client Adroit Client 1 1 Adroit Server Adroit Remote Clients 1 1 All prices are NETT 1 - 66 Notes: 1 2 ) 1 Scan Point = 1 PLC Variable. Internal variables are free. ) Requires Adroit SCADA server Licence of equivalent number of Scan Points. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Visualisation and reporting software Adroit SCADA SCADA Software Ordering details 1 Adroit Upgrades and Maintenance Agreements Description Adroit Upgrade The cost to upgrade from a previous version of Adroit depends both on the version number you are upgrading from and the system configuration in terms of the number of scan points, the number of clients and whether your system has a redundant server pair (cluster). Please contact NHP for a quote on Adroit Upgrades. Price $ Adroit Technology Agreement The Technology Agreement is a 12 month contract which entitles you to all Adroit upgrades and premium support for the period of the contract. The cost of the Technology Agreement depends both on the version number you have and the system configuration in terms of the number of scan points, the number of clients and whether your system has a redundant server pair (cluster). Please contact NHP for pricing on Adroit Technology Agreements. Notes: 1 Scan Point = 1 PLC Variable. Internal variables are free. Other variants including redundant servers (Clusters) available. Please contact NHP for more information. Training Price $ Adroit configuration Level I - 2 day course. This course is targeted at new Adroit users, configurators, technicians and engineers. The course sets the foundation for the next level course and provides delegates with the tools to implement and configure small projects. All commonly used features are covered in appropriate detail. The pre-requisite for attending this course is an understanding of SCADA and an operational knowledge of Microsoft Windows 95/98. Operational experience of Microsoft Windows 2000 / XP is an advantage. Adroit configuration Level II - 2 day course. This course is targeted at Adroit users, configurators, technicians and engineers who have successfully implemented at least one project. The concepts and principals presented in the Level I course are covered in depth, while additional features are introduced and explained. The pre-requisite for attending this course is the Level I configuration course as well as project experience. Contact NHP for further information. All prices are NETT For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 1 - 67 Switch mode power supplies Q Low power loss Q Electronic protection from short circuit, overload and over-voltage Q Voltage limiting Q Adjustable output Features Q 5 year warranty Q Quick mounting and connecting, innovative DIN rail Q High efficiency 1 Single phase switching power supplies Output Output power (W) voltage CSD series Output Inrush current (A) current Model type Cat No. XCSD15B ) ) 1 8 XCSD30C ) ) 15 12 V DC 1.2 <5 A CSD Series 30 24 V DC 1.2 <13 A CSD Series 12...15 V DC 3.5 <15 A CSD Series 24 V DC 3 <15 A CSD Series 24 V DC 3.5 <20 A 12...15 V DC 7 24 V DC 5 48 V DC 2.5 CSF Series 12...15 V DC 16 CSF Series 24 V DC 10 48 V DC 5 24 V DC 20 50 85 120 CSF Series 240 500 CSL Series CSF Series CSF Series <20 A <35 A <25 A CSL Series CSF Series CSL Series Price $ 1 8 1 7 8 XCSD50B ) ) ) 1 8 XCSD70C ) ) 1 8 XCSL85C ) ) 1 5 6 8 XCSF85CP ) ) ) ) XCSF120B ) ) ) ) 1 8 XCSL120C ) ) 1 6 7 8 XCSF120CP ) ) ) ) 1 6 8 XCSF120D ) ) ) 1 5 6 8 2 6 7 8 XCSF240B ) ) ) ) 2 8 XCSL240C ) ) CSF Series XCSF240CP ) ) ) ) 2 6 8 XCSF240D ) ) ) CSF Series 2 6 8 XCSF500C ) ) ) CSF Series 2 5 6 8 Three phase switching power supplies Output Output power (W) voltage CSL series Output Inrush current (A) current Model type Cat No. CSG Series XCSB150C ) ) 3 8 XCSB150D ) ) Price $ 3 8 24 V DC 6 48 V DC 3 240 24 V DC 10 <50 A CSG Series 500 24 V DC 20 <35 A CSG Series 720 24 V DC 30 <30 A CSG Series 1008 24 V DC 40 <20 A CSG Series 4 6 8 XCSG720C ) ) ) 4 8 XCSG42 ) ) 2400 24 V DC 100 <130 A CSG Series 4 8 XCSG2400C ) ) Output current (A) Inrush current Cat No. 150 <50 A CSG Series 4 6 8 XCSG240C ) ) ) 4 6 8 XCSG500C ) ) ) DC/DC Insulated converters CSG Series Input voltage V (DC) Output power (W) 120 Output voltage V (DC) 12 24 5 <60 A / <2ms XCSA120BC 24 12...15 7 <100 A / <2ms XCSA120CB 48 24 5 <120 A / <2ms XCSA120DC Price $ Accessories Price Schedule 1 - 68 Description Cat No. PS Batt charger module XCSBC PS redundant conn module XCSBD Notes: 1) 2 ) 3 ) 4 ) 5 ) ‘E9’ Wide range single-phase input Double range single-phase input Two-phase input Three-phase input With Oring diode for redundant parallel Price $ ) With failure contact (power good) ) With adjustable output ) UL508C approved 6 7 8 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2 Safety Safety interlock switches Series ST - 14: Light duty Series ES - 95: General purpose Series ST - 61: Heavy Duty Series ES - 95: General purpose rotary cam Series ES - 13SB: Light duty hinged Series ES - 95: General purpose flap/hinge Series STM 295: Medium duty solenoid Series AZM 415: Heavy duty Solenoid Non-contact Safety switches Series RC Si - M30 Series RC Si - 56 Series HSSi4 Series BZ16 Emergency stop trip-wire switch kits Emergency stop trip-wire switches Belt drift switches Limit switches Light duty 6 A: ES/EM 95 series Medium duty 10 A: PS21 series Medium duty 10 A: PS31 series Medium Duty 6 A:ES/EM 41 series Emergency stop trip-wire switches Type NTW cast aluminium Spare parts and accessories Installation instructions Heavy-duty limit switches: 77 HL and 77 TL series Safety Controllers Series NSC: Fail safe control unit Series MF1: Standstill monitor Series SRM: Fail safe control unit Limit switches - pull-wire (non safety) Foot operated switches Pressure switches 2-1 2-2 2-2 2-3 2-4 2-4 2-4 2-5 2-5 2-6 2-6 2-7 2-7 2-8 2-9 2 - 10 2 - 11 2 - 11 2 - 12 2 - 12 2 - 13 to 2 - 18 2 - 15 to 2 - 16 2 - 17 to 2 - 18 2 - 19 2 - 20 2 - 20 2 - 20 2 - 21 2 - 22 2 - 23 SAFETY INTER ERLOCK SW WITCHES NON-CONTACT SSAFETY SWITCHESS FOOT OPERATED SWITCHES LLIM IMIITT SWITCCHES EMERGENCY STTOP TRIP-W WIRE SWITCH H KITTS EMERGENCY STTOPP TRIP-WIRE SWITCHESS PRESSURRE SWITCHES Safety interlock switches Series ST -14: Safety interlock switch Light Duty - safety guard interlock IP 67 2 ST14 Actuator Action Type Contacts Fencing Adaptor Switch Cat. No. Retaining 1 N/O + 1 N/C BAC19 ST14-10/1S Retaining 2 N/C BAC19 ST14-20 Retaining 1 N/O + 1 N/C Ex-version BAC19 EEXST-14-10/1S 5M Accessories - actuators Switch Cat. No. Actuator Straight for ST14 ST14 B1 Actuator Right angle for ST14 ST14 B5 Actuator Spring loaded for ST14 ST14 B3 Price $ Price $ .140 Rm 16 30 15 R min Rm in.10 00 . 140 in .10 00 ø 4.2 38 35 ø 4 .2 53 R min 8 16 15 8 7,5 Dimensions in mm 11 11 ST 14 B1 ST 14 B5 ST 14 B3 Series ES-95: Safety interlock switch General purpose - safety interlock switch - machine guards IP 67 ES95AZ Actuator Action Type Contacts Fencing Adaptor Switch Cat. No. Retaining 1 N/O + 1 N/C BAC20 ES95AZ101S Retaining 2 N/C BAC20 ES95AZ20 Accessories - actuators Switch Cat. No. Actuator Straight for ES95 95AZB1 Actuator Right angle for ES95 95AZB5 Price $ Price $ Dimensions in mm 95AZB1 95AZB5 Price Schedule 'B2' 2-2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Safety interlock switches Series ST-61: Safety interlock switch Heavy Duty - safety interlock switch - machine guards IP 65 ST6110 1S Actuator Action Type Contacts Fencing Adaptor Retaining 1 N/O + 1 N/C BAC21 Switch Cat. No. ST6110/1S Retaining 2 N/C BAC21 ST6120 Accessories - actuators Switch Cat. No. Actuator Straight for ST61 ST61 B1 Actuator Right angle for ST61 ST61 B5 Price $ 2 Price $ Dimensions in mm ST61 B1 ST61 B5 Price Schedule 'B2' For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2-3 Safety interlock switches Series ES-95: Rotary cam interlock switch General purpose safety switch - guards, doors, covers, etc. 2 ES95SB101S IP Rating Contacts Material Switch Cat. No. IP 67 1 N/O + 1 N/C Thermoplastic ES95SB101S IP 67 2 N/C Thermoplastic ES95SB20 Price $ Series ES-13: Rotary cam interlock switch Light duty safety switch - guards, doors, covers, etc. IP Rating Contacts Material Switch Cat. No. IP 67 1 N/O + 1 N/C Thermoplastic ES13SB101S Price $ Series ES-95: Flap/hinge safety switch General purpose safety switch - machine guards ES13SB101S IP Rating Contacts Material Switch Cat. No. IP 67 1 N/O + 1 N/C Thermoplastic ES95T5C101S Price $ ES95T5C101S Price Schedule 'B2' 2-4 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Safety interlock switches Series STM: 295 Medium duty solenoid safety interlock switch Removable guards, doors, covers, etc. IP 67 Contacts Solenoid Action STM295202SR Solenoid Voltage Fencing Adaptor Switch Cat. No. STM295202SR STM295202SA Power unlock 2 N/O + 2 N/C 24 V DC BAC22 Power lock 2 N/0 + 2 N/C 24 V DC BAC22 Accessories - actuators Switch Cat. No. Actuator Straight for STM295 STM295 B1 Actuator Right angle for STM295 STM295 B5 Price $ 2 Price $ Dimensions in mm STM295 B1 STM295 B5 Series AZM 415: Heavy duty solenoid safety interlock switch Removable guards, doors, covers, etc. IP 67 Solenoid Action Contacts Solenoid Voltage Fencing Adaptor Switch Cat. No. Power unlock 2 N/O + 2 N/C 24 V DC BAC23 AZM415202SR3D Power lock 2 N/0 + 2 N/C 24 V DC BAC23 AZM415202SA3D AZM415202SR3D Accessories - actuators Switch Cat. No. Actuator Straight for AZM415 AZM415 B1 Actuator Adjustable X axis for AZM 415 AZM415 B2 Actuator Adjustable Y axis for AZM 415 AZM415 B3 Price $ Price $ Dimensions in mm AZM415 B1 AZM415 B2 AZM415 B3 Price Schedule 'B2' For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2-5 Non-contact safety switches Series RC Si-M30: Magnetic coded safety switches - IP 67 RC Si Recommended to be used with SRM 21 RT2 relay 2 Description Contacts Cat. No. Magnetic cylinder M30 1 N/O + 1 N/C RCSIM30101S5M Magnetic cylinder M30 2 N/C RCSIM30205M Accessories - actuators Cat. No. Coded magnet MC30 Price $ Price $ RCSIM30101S5M Dimensions in mm MC30 Series RC Si-56: Magnetic coded safety switches - IP 67 RC Si Recommended to be used with SRM 21 RT2 relay Description Contacts Fencing Adaptor Cat. No. Magnetic switch rectangle 1 N/O + 1 N/C BAC24 RCSI56101S5M Magnetic switch rectangle 2 N/C BAC24 RCSI56205M Accessories - actuators Cat. No. Coded magnet MC56 Price $ Price $ Dimensions in mm RCSI56101S5M MC56-3 Price Schedule 'B2' 2-6 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Non-contact safety switches Series HSSi 4 : Hall sensor - IP 67 General duty guard door monitor HSSI4101S Descriptions Contacts Cat. No. Hall sensor 1 N/O + 1 N/C HSSI4101S Hall sensor 2 N/C HSSI420 Accessories - actuators Cat. No. Actuator MC4 Price $ Price $ 2 RCSIM30101S5M Series BZ16 : Induction/Hall sensor - IP 67 General duty guard door monitor BZ16 11 Face actuation Contacts Cat. No. Front 1 N/O + 1 N/C BZ1611V Top 1 N/O + 1 N/C BZ1611D Bottom 1 N/O + 1 N/C BZ1611U Front 2 N/C BZ1602V Top 2 N/C BZ1602D Bottom 2 N/C BZ1602U Accessories - actuators Cat. No. Actuator BZ16B1 Price $ Price $ Actuation face BZ16 B1 Price Schedule 'B2' For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2-7 Emergency stop trip-wire switch “kits” Series TQ ZS: Trip-wire switches Emergency stop for conveyor and various other industries TQZS70...8 metres Slim housing Trip-wire Switch 2 Trip-wire length TQZS70... kit TQZS70101SVD Items included in kit 1) Cat. No Price $ 1 x TQZSTS150N 8 metres TQZS-70 8 x TQZSWR5MM (cable) TQZS70KIT10M 3 x 55150 (wire support) TQZS71...5-20 metres Small housing TQZS71... kit TQZS71101 1 x TQZSTS250N 20 metres 20 x 55153P (cable) TQZS71KIT20M 5 x 55150 (wire support) TQZS-71... TQZS73...30-50 metres General purpose TQZS73... kit TQZS3101SWVD 1 x TQZSTS250N (spring) 50 metres 50 x 55153P (cable) TQZS73KIT50M 10 x 55150 (wire support) TQZS-73... TQZS-75...30-50 metres Large housing TQZS75... kit TQZS75101SWVD 1 x TQZSTS250N (spring) 50 metres 50 x 55153P (cable) TQZS75KIT50M 10 x 55150 (wire support) TQZS-75... TQZS80...10-50 metres With emergency stop and flag indicator TQZS80... kit TQZS80202SWVD 1 x TQZSTS250N (spring) 50 metres 50 x 55153P (cable) TQZS80KIT50M 10 x 55150 (wire support) TQZS-80 Notes: Price Schedule ‘B2’ 2-8 ) Items included in all of the above kits 1 x Tension spring (As per requirement AS 1755-2000) 1 x 55164, turnbuckle 4 x 55151, thimble 8 x 55152, wire clamps _ x Cable (quantity as above) _ x 55150, wire support (quantity as above) Wire supports are based upon supporting the trip-wire at 2.5 - 3 metre intervals. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Emergency stop trip-wire switches Series TQZS : Trip-wire switches Emergency stop for conveyor and various other industries 55153P Wire rope Trip-wire length (metres) Contact arrangement Description Cat. No. Price $ 0-8 m (1 N/O + 1 N/C) TQZS-70 10/1S VD ) 5-20 m (1 N/O + 1 N/C) TQZS-71 10/1SWVD 1) 5-20 m (2 N/C) TQZS-71 20 WVD 1) 5-20 m (1 N/O + 1 N/C) 30-50 m (1 N/O + 1 N/C) TQZS-73 10/1SWVD 1) 30-50 m (2 N/C) TQZ-73 20 WVD 1) 30-50 m (1 N/O + 1 N/C) 30-50 m (1 N/O + 1 N/C) TQZS-75 10/1S WVD 1) 30-50 m (2 N/O + 2 N/C) TQZS-75 20/2S WVD 1) 10-50 m (2 N/O + 2 N/C) TQZS-80 20/2S WVD 1) 2 Ex version Ex version 2 EEXZS-71 10/1S WVD 1) EEXZS-73 10/1S WVD 1) Series TQ441/T3Z : Trip-wire switch Emergency stop for conveyor and various other industries Trip-wire switch TQ441-01/01YUR137 Trip-wire length (metres) Contact arrangement Description Cat. No. 5-25 m (1 N/C + 1 N/C) Cast Iron Body TQ441 01/01 YUR 137 ) 0-5 m (1 N/C + 1 N/C) 35 N Type TQ441 01/01 YUR 157 2) 5-25 m (1 N/C + 1 N/C) Cast Aluminium TQ441 01/01 YUR 1) Price $ 1 Trip-wire switch accessories 55152 Wire clamp Description Cat. No. Steel wire red PVC covered 7 mm Ø (per metre) 55153P Tension spring heavy duty TQZSTS250N Tension spring light duty TQZSTS150N Wire support bracket 55150 Wire clamp / shackle 55152 Thimble 55151 Turnbuckle 55164 Tensioning device (for 5 mm Ø wire) S900 Price $ 55150 Wire support Notes: Price Schedule ‘B2’ ) Use in combination with TQZSTS250N tension spring and 55153P 7 mm wire rope. ) Use in combination with TQZSTS150N tension spring and TQZSWR5MM 5 mm wire rope. 1 2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2-9 Belt drift switches Series ES 61 SR: Belt drift switch Light duty 2 IP Rating Contacts Material Cat. No. IP 65 1 N/O + 1 N/C Aluminium ES61SR101S Price $ Series ZS 73 SR: Belt drift switch General duty ES61SR101S Description Contacts Material Cat. No. IP 65 1 N/O + 1 N/C Aluminium ZS73SR101S Price $ Series ZS 75 SR: Belt drift switch General duty ZS73SR101S IP Rating Contacts Material Cat. No. IP 65 1 N/O + 1 N/C Aluminium ZS75SR101S IP 65 2 N/O + 2 N/C Aluminium ZS75SR202S Price $ Series ZS 90 SR: Belt drift switch Heavy duty ZS75SR101S IP Rating Contacts Material Cat. No. IP 67 2 N/O + 2 N/C Duroplast ZS90SR10S10S Price $ ZS90SR202S Price Schedule ‘B2’ 2 - 10 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Limit switches Light Duty 6A (Ithe) IP 67 ES/EM 95 series 1) 1 N/O & 1 N/C Actuator W ES95W101S R 4K D DS ES95D101S DD TL TK Action Slow Body Material Plastic Cat. No. ES95W1O1S Snap Plastic EM95W1O1S Slow Plastic ES95R1O1S Snap Plastic EM95R1O1S Slow Plastic ES954K1O1S Snap Plastic EM954K1O1S Slow Plastic ES95D1O1S Snap Plastic EM95D1O1S Slow Plastic ES95DS1O1S Snap Plastic EM95DS1O1S Slow Plastic ES95DD1O1S Snap Plastic EM95DD1O1S Slow Plastic ES95TL1O1S Snap Plastic EM95TL1O1S Slow Plastic ES95TK1O1S Snap Plastic EM95TK1O1S Price $ 2 Dimensions in mm ES95DS101S ES95 Medium Duty 10A (Ithe) IP 66 PS 21 L series 1) 1 N/O & 1 N/C Actuator PS21LMS11PR00 PO PR RT R1 Action Slow Body Material Metal Cat. No. PS21LM11P0M00 Snap Metal PS21LMS11P0M00 Slow Metal PS21LMT11PRM00 Snap Metal PS21LMS11PRM00 Slow Metal PS21LMT11RTM00 Snap Metal PS21LMS11RTM00 Slow Metal PS21LMT11R1M00 Snap Metal PS21LMS11R1M00 Price $ PS21LMS11POM00 Dimensions in mm 107/4.21” 37/1.46” 16/0.63” Ø10/ 0.39” PS21L Price Schedule 'B2' Notes: ) Versions with 2 N/0 or 2 N/C contacts available on indent. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2 - 11 Limit switches Medium duty 10A (Ithe) IP 65 PS 31 L series 1) 1 N/O & 1 N/C Actuator PO 2 PR RV PS31LMT11RT00 RT R1 Body Material Plastic Cat. No. PS31LMT11P0T00 Snap Plastic PS31LMS11P0T00 Slow Plastic PS31LMT11PRT00 Snap Plastic PS31LMS11PRT00 Slow Plastic PS31LMT11RVT00 Snap Plastic PS31LMS11RVT00 Slow Plastic PS31LMT11RTT00 Snap Plastic PS31LMS11RTT00 Slow Plastic PS31LMT11R1T00 Snap Plastic PS31LMS11R1T00 Price $ 16/0.63” 16/0.63” 10/0.39” 5/0.20” Ø12/0.47” Ø10/ 0.39” 120/4.72” 107/4.21” 50/1.97” 30° 37/1.46” 20/0.79” Dimensions in mm 44/1.73” PS31LMS11RT00 Action Slow Heavy duty 6A (Ithe) IP 65 ES/EM 41 series 2) 1 N/O & 1 N/C Actuator W R ES41R101S D DS TL Action Slow Body Material Metal Cat. No. ES41 Snap Metal EM411O1S Slow Metal ES41R1O1S Snap Metal EM41R1O1S Slow Metal ES41D1O1S Snap Metal EM41D1O1S Slow Metal ES41DS1O1S Snap Metal EM41DS1O1S Snap Metal EM41TL1O1S Price $ Dimensions in mm ES41DS101S ES41 ES41TL101S Notes: Price Schedule ‘B2’ 2 - 12 ) Versions with 2 N/O or 2 N/C contacts available on indent, except Steute snap action models. ) Versions with 2 N/C contacts available on indent. 1 2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer Publication 55-NTW, C-100 Emergency stop trip-wire switch Type NTW Cast aluminium type Protection class IP 65 and IP 67 Features Trip-wire switch with flag indicator, pilot light, lamp and lens 55.4.01 NBB Q Q Q Q Q Q Q Q Q Q Q Q Rugged construction - cast aluminium housing Non-ferrous components throughout All operating shafts & springs are stainless steel Hoseproof - dustproof IP 65 & IP 67 enclosure Complies with AS 1755-2000/AS 1939-1990 Standard unit supplied with 2 N/O + 2 N/C silver wiping action contacts. Flag indicator & padlocking facility supplied as standard (Padlocking is for prevention of manual reset only) Single or double sided operation Fail-safe mechanism including removal or breakage of either wire Cannot break the N/C circuit without latching open Switch must be manually reset Ex Version complies with AS/NZS 61241 2 Optional window for external adjustment UV resistant neoprene seals Manual reset Pilot light/indicator IP 65/67 protection Padlocking feature For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2 - 13 Emergency stop trip-wire switch Type NTW NTW Trip-wire switches, standard range Q Q Q IP 65/IP 67 padlockable trip-wire switches Single-sided or double-sided operation Supplied with silver wiping action contact blocks (gold available on request). 55.4.01 NBB Dimensions (in mm) 2 Trip wire switch with glass window 55.4.00 GWNBB Ordering details Description Trip-wire switch Trip-wire switch Trip-wire switch single-sided right single-sided left double-sided Cat. No. 1) 2) 3) Price $ Cat. No. 1) 2) 3) Price $ Cat. No. 1) 2) 3) Price $ Standard switch with 2 N/O 55.4.00NBB 1380.00 55.4.00LHNBB 1400.00 55.4.00RHNBB + 2 N/C contact blocks Standard switch with glass 55.4.00GWNBB 1580.00 55.4.00LHGWNBB 1610.00 55.4.00RHGWNBB window and 2 N/O + 2 N/C contact block Standard switch with pilot 55.4.01NBB 1390.00 55.4.01LHNBB 1480.00 55.4.01RHNBB light and 2 N/O + 2 N/C contact block 4) 55.4.00LH NBB Standard switch with amber 55.4.01STRANBB 1800.00 – strobe indication and 2 N/O – + 2 N/C contact block 6) Explosion proof (Ex) trip-wire switch Q Q Special trip-wire switch for hazardous environments such as grain handling. Supplied with 2 N/O + 2 N/C contact blocks. Complies with AS/NZS 61241. Description Switch with Standard switch Glass window Price $ Cat. No. 1) 2) Cat. No. 1) 2) Standard switch with 2 N/O EX55400NBB Switch with lid mounted pilot light Price $ Cat. No. 1) 2) 5) Price $ 1710.00 EX55400GWNBB 1970.00 EX55401NBB + 2 N/C contact block Ex 55.4.00 NBB Notes: ) Installation information, lanyard rope and accessories, refer pages 6 - 15 to 6 - 18. 2 ) Also available with gold plated contacts at extra cost – insert ‘G’ at the end of Cat. No. Contact NHP for additional price. 3 ) Suitable for use with conveyor control and monitoring communications systems. Contact the NHP Automation team to discuss your requirements. 4 ) Supplied with red and amber lenses, lamp must be ordered separately. 5 ) Supplied with red lens, lamp must be ordered separately. 6 ) Supplied with Allen-Bradley 45 mm strobe light 855PSB30ME522. 1 Price Schedule ‘B2’ 2 - 14 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Emergency stop trip-wire switch Type NTW Lanyard accessories Price $ ‘D’ Shackle Standard Cat. No. - 316 Grade Stainless Steel Cat. No. 55.2.19NTW Tension spring suits NTW 55.4 only 1) 55.2.46 80.00 55.2.46SS Lanyard support bracket 55.1.50 29.60 55.1.50SS 5 mm thimble/sleeve 55.1.51 11.40 55.1.51SS 5 mm clamp/shackle 55.1.52 9.90 55.1.52SS Turnbuckle hook and eye 10 mm x 145 mm 4) 55.1.64 33.00 55.1.64SS Description 55.1.50 wire support Spare parts 55.1.52 wire clamp 2551 SES 110V lamp Lid gasket Cat. No. 55.2.17 Shaft bellows 3) 55.2.37 Spare Lid for 55.4.00 2) 55.2.16 Spare Lid for 55.4.00GW 2) 55.2.16GW Spare Lid for 55.4.01 2) 55.2.16PL Spare contact blocks/Lamp block Standard Silver contact Cat. No. 1 N/O + 1 N/C contacts 2 N/O + 2 N/C contacts 3 N/O + 3 N/C low voltage micro contact set - Price $ 2 Price $ Price $ Gold contact Cat. No. NBAFP 55.00 NBAG NBBFP 109.00 NBBG Price $ 554LVKIT and bracket Lamp block for 55.4.01 (suit SES lamp) VFBC 106.00 - Spare lamps SES style for trip-wire pilot light 5) 6) 55.2.46 Tension spring To suit Full voltage pilot light Voltage SES 12 V 4 W Cat. No. NO2243 Full voltage pilot light 24 V 4 W NO2242 Resistor and full voltage pilot light 110 V 4 W NO2551 Resistor and full voltage pilot light 260 V 4 W NO2556 Price $ 55.1.51 Thimble / sleeve Notes: ) ) 3 ) 4 ) 5 ) 6 ) 1 2 55.2.46 tension spring is only suitable for NTW 55.4 trip-wire switches. Supplied complete with gasket 55.2.17. Use with clip 55.2.40. Eye/Eye turnbuckle available contact NHP. Other voltages available contact NHP. Stock brought in to order on some voltages. Price Schedule ‘B2’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2 - 15 Refer catalogue SAFT Emergency stop trip-wire switch Type NTW Accessories and spare parts Lanyard rope / Trip-wire Developed to meet AS/NZS conveyor safety standard AS 1755-2000 these ropes are specially tested to work in conjunction with the NHP/Austrol NTW 55.4 series trip wire switches. Two types are available, i.e. PVC covered galvanised trip-wire, and the new NHP/Tufflex™ fibre lanyard rope. 2 Ordering details Red PVC covered galvanised trip-wire 55.1.53P Cat. No. Description Wire rope 7 mm dia. Per metre Price $ 55.1.53P (4 mm wire coated in 3 mm RED UV resistant PVC) NHP/Tufflex™ fibre lanyard rope A unique combination of properties differentiates NHP/Tufflex™ fibre from other high-performance fibres and makes it the material of choice to meet performance requirements in demanding applications. The remarkable mechanical performance of NHP/Tufflex™ combined with the other unique properties, permit it to be used for a wide variety of purposes. NHP/Tufflex™ unique fibres are used in aerospace, ocean exploration and development, electronic support structures, safety materials, industrial applications, composites, protective apparel and highpressure inflatables. NHP/Tufflex™ is a high-performance multi-filament yarn spun from liquid crystal polymer (LCP). It is the only commercially available melt-spun LCP fibre in the world exhibiting low weight and exceptional strength and rigidity. It is five times stronger than steel and ten times stronger than aluminium. These unique properties characterise NHP/Tufflex™: Q Q Q Q Q Q 55.1.53RLR High strength and modulus Excellent creep resistance High abrasion resistance Excellent flex/fold characteristics Minimal moisture absorption Excellent chemical resistance Q Q Q Q Q Q Low coefficient of thermal expansion (CTE) High dielectric strength Outstanding cut resistance Excellent property retention at high/low temperatures Outstanding vibration damping characteristics High impact resistance Ordering details LCP Fibre lanyard rope Description NHP/Tufflex™ RED fibre lanyard rope 7mm dia. (105 m roll) Cat. No. 55.1.53RLR NHP/Tufflex™ RED fibre lanyard rope 7mm dia. per metre 55.1.53RLR-PM Price $ See page 6 - 17 to 6 - 18 for set up instructions. See page 6 - 15 for spare parts and accessories. Price Schedule ‘A2’ 2 - 16 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Emergency stop trip-wire switch Type NTW – Protection class IP 65 and IP 67 Method of installation For single and double-sided operation Single-sided operation Tripwire/lanyard connected to one side of the trip-wire switch (either left or right) and terminated with a return compensation (tension) spring. 2 X Metres Max. 4.0 4.0 Wire Supports 55.1.50 Tension Spring Turnbuckle 55.2.46 55.1.64 Double-sided operation Tripwire/lanyard connected to both left and right hand sides of the trip-wire switch. Both left and right hand lanyards are terminated with a return compensation (tension) spring. X Metres Max. 4.0 X Metres Max. 4.0 4.0 Wire Supports 55.1.50 Tension Spring Turnbuckle 55.2.46 55.1.64 4.0 Wire Supports 55.1.50 Turnbuckle Tension Spring 55.1.64 55.2.46 Multiple double-sided installations For longer conveyor runs, must be installed as shown below: X Metres Max. 4.0 X Metres Max. 4.0 4.0 Wire Supports 55.1.50 Tension Spring Turnbuckle 55.2.46 55.1.64 • • • 4.0 Wire Supports 55.1.50 Turnbuckle Tension Spring 55.1.64 55.2.46 X Metres Max. 4.0 4.0 Wire Supports 55.1.50 Tension Spring Turnbuckle 55.2.46 55.1.64 X Metres Max. 4.0 4.0 Wire Supports 55.1.50 Turnbuckle Tension Spring 55.1.64 55.2.46 Individual maximum lengths of lanyard (shown as ‘X’ in the diagrams above) in a horizontal plane must not exceed: – 100 m when using NHP/Tufflex™ Lanyard rope (Cat. No. 55.1.53RLR) – 60 m when using NHP red PVC coated galvanised steel cable (Cat. No. 55.1.53P) NHP recommends the use of NHP/Tufflex™ as the lanyard when the conveyor system is operating over a 5 degree incline from the horizontal. NHP strongly recommends that pulleys are not used with the galvanised steel cable – i.e to curve the tripwire/lanyard around conveyor bends, etc. – and that pulleys only be used with NHP/Tufflex™ as the lanyard. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2 - 17 Emergency stop trip-wire switch Type NTW – Protection class IP 65 and IP 67 Method of installation For single and double-sided operation 1. 2 Firmly mount the trip-wire switch using the four (4) mounting points on the trip-wire unit: A. For Double-Sided Installations • A maximum of 100 m from one end of the conveyor when using NHP/Tufflex™, or • A maximum of 60 m from one end of the conveyor when using NHP PVC coated galvanised cable as the lanyard. B. For Single-Sided Installation Mount the trip-wire switch at one end of the conveyor, ensuring that the maximum length of the tripwire/lanyard does not exceed: • 100 m when using NHP/Tufflex™ or, • 60 m when using NHP PVC coated galvanised wire as the lanyard. Note: If either of the above distances are to be exceeded, then a double-sided installation must be used. 2. Fit the return compensation (tension) spring: C. When using NHP/Tufflex™ as the lanyard: A maximum of 100 m from each side of the trip-wire switch for double-sided installations, or a maximum of 100 m from one side of the trip-wire switch for single-sided installations. D. When using NHP PVC coated galvanised steel wire as the lanyard: A maximum of 60 m from each side of the trip-wire switch for double-sided installations, or a maximum of 60 m from one side of the trip-wire switch for single-sided installations. 3. Position lanyard wire supports at a maximum spacing of 4 m between the return compensation spring and the trip-wire switches. Smaller spacings will ensure higher performance of the trip-wire system. 4. Run the lanyard between the trip-wire switch and the return compensation springs. 5. Terminate the lanyard at the return compensation spring ends using thimbles and clamps. If using the PVC coated galvanised cable, remove outer PVC sheathing before clamping. Secure to the return compensation spring using ‘D’ shackle if necessary. 6. Unwind both ends of the turnbuckle/s to give maximum extension and hook one end to the shaft of the trip-wire switch using the provided ‘D’ shackle. 7. Terminate the other end of the lanyard to the turnbuckle/s using thimbles and clamps. If using the PVC coated galvanised cable, remove outer PVC sheathing before clamping. Before tightening clamp to lanyard, pull through all slack until taught, then tighten clamp. 8. Attach the external setting gauge/s using the screws provided, into the threaded holes, either above or below the external trip-wire switch shafts. 9. Adjust the turnbuckle/s until the end of the shaft is in-line with the end of the setting gauge. 10. Pull the lanyard numerous times to ‘bed-in’ the cable and remove any ‘deadband’ from the system. If necessary, re-adjust the turnbuckle until the end of the shaft is in-line with the end of the setting gauge. If desired, the setting gauge can now be removed. 11. The trip-wire switch set-up is now complete. 55.4.00 NBB Open view 2 - 18 Schematic showing operating lever centred in the middle of the operating cam. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Heavy-duty limit switches 77 HL and 77 TL Series Features of 77 series switches Q Q Q Q Q Q Q Q Australian designed and manufactured Proven reliability in adverse conditions Durable cast construction Weatherproof and dustproof to IP 54 Double-break long life silver contacts 1) 10 Amp 440 V AC 12 Non-ferrous metal components Optional roller styles (track limit switches only) Q Selectable side or bottom mounting (hatchway only) Hatchway limit switch double pole 77.1.10 with 77.2.40 lever Oil impregnated bearing, needs no lubrication Malleable iron operating lever adjustable to any angular position Plastic moulded cams Heavy duty toggle mechanism snap action 2 Double break silver-to-silver contacts Tapped conduit hole Cast dustproof and weatherproof enclosure Integrally cast mounting feet Series 77 HL Cast aluminum Hatchway limit switch 1) (Spring return to centre) Description Contacts 1) Hatchway limit switch with straight roller lever and 1 N/O or 1 N/C Cat. No. 77.1.06 Price $ single pole contact Hatchway limit switch with straight roller lever and 1 N/O + 1 N/C 77.1.10 changeover contacts Series 77 TL Cast iron Track limit switch 1) (Stayput) Track limit switch double pole 77.2.11 with 77.2.39 lever Description Contacts 1) 1 N/O or 1 N/C Cat. No. 77.2.50 1 N/O + 1 N/C 77.2.11 Description Single pole contact blocks (spare part) Contacts 1) 1 N/O or 1 N/C Cat. No. Changeover contact blocks (spare part) 1 N/O + 1 N/C 77.1.31 Track limit switch without lever and single pole Price $ contact - choose lever below Track limit switch without lever, with changeover contacts - choose lever below Accessories for series 77 HL and 77 TL switches Double pole contact block 77.1.31 Price $ 77.1.30 Spare rod or chain lever - for 77 TL switches only 77.2.34 Spare cam for changeover contacts 77.1.21 Spare cam screw for changeover contacts 77.1.25 Spare lever straight - for HL switches 77.2.40 Spare lever fork - for TL switches 77.2.39 Lever- rod or chain 77.2.34 Price Schedule ‘B2’ Notes: ) Please state precise ohm value (1 to 50) when ordering. ) Prices are per each (kit). 1 2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2 - 19 Safety controllers Series NSC: Fail safe control unit Monitoring of safety gate switches and Carlo Gavazzi safety coded magnetic switches Safety Cat. Stop Cat. Voltage Rating 2 NSC02DB24DA Enabling Sensor Config. paths Type reset Cat. No. Price $ 4 0 24 V AC / DC 2 N/C or 1 N/C 3 Auto/manual NSC13DB24DA 4 0 24 V AC / DC 2 N/C or 1 N/C 3 Monitored NSC13DB24DC Series MF1: Standstill monitor Safety Cat. Rating Stop Cat. Voltage Input Config. Enabling paths Type reset Cat. No. 3 - 24 V AC / DC 1 or 3 phase 2 - MF1C Price $ MF1C Series SRM: Fail safe control unit Monitoring of E-stops, safety gate switches and Steute safety coded magnetic switches Safety Cat. Stop Cat. Voltage Rating Sensor Config. Enabling paths Type reset 4 2 N/C or 2 0 24 V DC Auto/manual Cat. No. Price $ SRM21RT2 1 N/0 + 1 N/C SRM21RT2 Price Schedule 'B2' 2 - 20 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Limit switches - Pull wire (non safety) Heavy / Medium Duty 4 A (Ithe) IP 65 Pull Wire Switch 4 A (Ithe) Non-emergency Q Q Q Q ES41… Aluminium die-cast body Protection class IP 65 Slow action 2 contacts Spring return (impulse) Contacts Cat. No. 1 N/O+1 N/C ES41Z 101S Price $ 2 Pull Wire Switch 4 A (Ithe) Non-emergency Q Q Q Q Heavy - Duty Protection class IP 65 Aluminium die-cast body Spring return (impulse) Contacts Cat. No. 1 N/C+1 N/C TQ441010YU Price $ TQ441… Price Schedule ‘B2’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2 - 21 Foot operated switches Type GF, GFS Series GFM - 4 A (Ithe), Series GF - 16 A (Ithe) - foot switches aluminium, IP 65 General purpose and heavy duty types Unguarded Cat. No. Price $ Guarded Cat. No. GF 101S 300.00 GFS 101S Replacement Contacts Price $ Cat. No. Price $ 340.00 1x ES 60GF Snap 1 Pedal, 1 N/O 1 N/C GFM 101S 320.00 GFSM 1O1S 345.00 1x ZS23211 Snap 1 pedal 2 N/O 2 N/C GFM 202S 360.00 GFSM 2O2S 400.00 2x EM 40 GF KIT Slow 1 pedal 2 N/O 2 N/C GF 2O2S 330.00 GFS 202S 415.00 2x ES 40 GF KIT Slow 1 Pedal, 1 N/O 1 N/C GF 10SD10S 570.00 GFS 10SD10S 580.00 1x ES 40GF KIT GF POTI_OHM 670.00 GFS POTI_OHM 740.00 Action /Description Slow 1 Pedal, 1 N/O 1 N/C 2 Foot switch (unguarded) GF/GFM… with pressure point (2 stage) Slow 1 Pedal, with - potentiometer ) 1 Foot switch (guarded) GFS/GFSM… Slow 2 Pedal, 1 N/O 1 N/C GF2 10S10S 570.00 GFS2 10S/10S 620.00 2x ES 60 GF Slow 2 Pedal, 2 N/O 2 N/C GF2 20S20S 680.00 GFS2 20S/20S 850.00 2x ES 40 GF KIT Slow Explosion proof EEX GF1O1S 700.00 EEX GFS1O1S 790.00 - Series GFS : Safety foot switch GFS Safety foot switch IP Rating Contacts Cat. No. IP 65 IP 65 1 N/O + 1 N/C 2 N/O + 2 N/C GFS1SD 10VD GFS2SD 20VD Notes: Price $ ) Please state precise ohm value (1 KΩ to 50 KΩ) when ordering. ) Prices are per each (kit). 1 2 Price Schedule ‘B2’ 2 - 22 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Pressure switches General purpose and industrial type GPS series – General purpose (IP 54) Features Q Q Q Q Q Wide selection of transducer wetted materials suitable for air, water, oil and for corrosive fluid Field adjustable set points and differential Internal components and bellows are treated and chrome plated to ensure long life Provided with single C/O snap-action switch 1) GPS-B025-FN4-VD 20 mm cable entry Allowable pressure Cat. No. Pressure range Pressure differential Price $ Minimum Maximum Minimum Maximum Maximum allowable allowable allowable allowable kPa psi kPa psi kPa psi kPa psi kPa psi 0 - 300 43.5 50 7.25 250 36.2 1500 217 GPS-B015-FN4-VD 0 - 600 87 60 8.7 350 50.72 1500 217 GPS-B025-FN4-VD 100 14.5 1000 145 80 11.6 450 65.2 1500 217 GPS-B045-FN4-VD 2 IPS series – Industrial range (IP 65) Features Q Q Q Q Q Q Q Wide selection of transducer wetted materials suitable for air, water, oil and corrosive fluid Field adjustable set points and differential IP 65 enclosure with 20 mm cable entry Set point repeatability, ±1 % of operating range One changeover snap-action switch 1) Every internal part and bellows of the switch is chrome plated and treated to ensure long life Mounting bracket is provided with switch for ease of installation Pressure range Minimum Maximum allowable allowable kPa psi kPa psi 10 1.45 500 72.5 Pressure differential Minimum Maximum allowable allowable kPa psi kPa psi 2.90 20 400 58 20 2.90 700 101.45 25 3.60 400 40 5.80 1000 145 30 4.35 600 Allowable pressure Maximum Cat. No. kPa 1500 psi 217 IPS-B026-FN4-VD 58 1500 217 IPS-B036-FN4-VD 87 1500 217 IPS-B046-FN4-VD Price $ Selecting desired ‘cut-off’ and differential Calculating differential pressure – e.g. IPS-B026-FN4-VD Specifications Q Q Q 1 N/O + 1 N/C contacts Female NPT ¼” connection port Bellows material: PBP-3 (phosphor bronse) 90ºC Notes: 1 ) AC rating 240 V, 10 A. DC rating 24 V, 3 A. Price Schedule ‘B3’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 2 - 23 3 Soft starters and drives Electronic soft starters product selection guide S+S PCS - introduction, specifications and ordering details AuCom CSX and CSXi - introduction, specifications and ordering details EMX3 - introduction, specifications and ordering details Variable Speed Drives Product selection guide Santerno SINUS Nano range - introduction, standard specifications and ordering details SINUS Micro range - introduction, standard specifications and ordering details SINUS Nano and Micro ranges - options SINUS Penta range - introduction, standard specifications and options SINUS Penta - range and selection (380 - 415 V) Input and output choke - ordering details Semiconductor fuses and accessories - ordering details Brake resistor selection by duty cycle Brake resistors and accessories - ordering details Rating and selection chart SINUS Penta - range and selection (660 - 690 V) SINUS Penta - multi-pump application and regenerative application SINUS Penta - options SINUS Penta - specifications 3- 1 3-2 3-4 3-7 3 - 12 3 - 23 3 - 24 3 - 25 3 - 26 3 - 27 3 - 32 3 - 35 3 - 36 3 - 37 3 - 38 3 - 40 3 - 44 3 - 46 3 - 48 3 - 49 SOFT STARTERS S SINUS NANO VARIABLE SPEED DRIIVE SINUS MICRO VARIABLE SPEED DRIVE SOFT STARTERS SINUS PENTA VARIABLE SPEED DRIVE Soft starters Product selection guide Introduction NHP offers an extensive range of soft starter products to ensure your technical and commercial objectives are easily satisfied. The following table provides an overview of the features available from each model and an indication of the duty cycles (Light, Medium, Heavy & Severe) that the products are suited to. When used in conjunction with the table on page 3 - 3, accurate soft starter selection for your intended application is assured. Cat No. PCS CSX Power range 3 1.1 - 45 kW, 3 wire 2.2 - 75 kW, 6 wire Voltage range 200 - 480 V AC 7.5-110 kW, 3 wire 7.5 - 110 kW, 3 wire 200 - 440 V AC 200 - 440 V AC 7.5 - 800 kW, 3 wire 11-1500 kW, 6 wire 200 - 440 V AC 200 - 690 V AC 1) Strategy Closed loop, controlled current Open loop, controlled voltage Closed loop, controlled current Closed loop, controlled current Controlled phases 3 2 with Equi-Vec TM 2 with Equi-Vec TM 3 Utilisation category AC 53b, built-in bypass AC 53b, built-in bypass AC 53b, built-in bypass AC 53a, continuous AC 53b, bypassed User adjustment DIP switch Rotary switch Rotary switch Digital keypad Start modes Timed voltage ramp Current limit Kick-start Timed voltage ramp Constant current Timed current ramp XLR-8 adaptive acceleration Constant current Current limit Kick-start Stop modes Soft stop Soft stop Soft stop XLR-8 adaptive deceleration TVR soft stop Brake mode Protection Overload c/w adj. trip class Phase imbalance Phase sequence Line fault/open load Starter over-temp Shorted SCR Line fault/open load Shorted SCR Comms error Supply frequency Overload c/w adj. trip class Motor thermistor Excess start time Phase imbalance Phase sequence Line fault/open load Shorted SCR Comms error Overload c/w prog thermal model Motor thermistor Excess start time Phase imbalance Phase sequence Electronic shearpin Under-current Aux. trip input Line fault/open load Starter over-temp Shorted SCR Comms error Outputs 1 x Fixed 1 x Programmable 1 x Optional 1 x Fixed 1 x Fixed 1 x Programmable 1 x Fixed 3 x Programmable Inputs 1 x Start 1 x Stop 1 x Start 1 x Stop 1 x Start 1 x Stop 1 x 4-20 mA Prog 1 x Start 1 x Stop 1 x Reset 2 x Programmable 1 x PT 100 Indication 1 Flash coded LED 2 Flash coded LEDs 2 Flash coded LEDs Multi-line plain English graphical display Sundry Various accessories to integrate with S+S switchgear products 1) Remote operator 1) Modbus module 1) DeviceNet Module 1) Profibus Module 1) Semiconductor fuses 1) Remote operator 1) Modbus module 1) DeviceNet Module 1) Profibus Module 1) Semiconductor fuses1) Simulation modes Dual parameter sets Trip log Event log Starts / hours counter Auto-stop Emergency run mode Modbus, DeviceNet, Profibus, USB 1) Remote mount keypad 1) 690 V AC 1) Semiconductor fuses 1) Expansion I/O 1) RTD/ Ground fault module 1) Applications Light & Medium duty (Refer page 3-3) Heavy duty with derating Light, Medium & Heavy duty Light, Medium & Heavy duty Light, Medium, Heavy & Severe duty Page reference 3-7 3-9 3 - 12 3-4 Note: 3-2 EMX3 CSXi ) Optional extra 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft starters Applications and duty cycle categories Electronic soft starters Soft starter ratings are influenced by several factors but none more so than the starting time and starting current characteristics of the driven machine. The following table, when used in conjunction with the ratings matrices provided on the following pages, ensures accurate soft starter selection. Application Duty Application Duty Agitator Heavy Fan - High pressure Severe Atomiser Heavy Grinder Medium Bottle washer Light Hydraulic power pack Medium Centrifuge Severe Mill Severe Chipper Severe Mill - Ball Severe Compressor - Recip (Loaded) Severe Mill - Hammer Severe Compressor - Recip (Unloaded) Heavy Mill - Roller Severe Compressor - Screw (Loaded) Severe Mixer Severe Compressor - Screw (Unloaded) Heavy Palletiser Severe Conveyor - Belt Severe Planer Medium Conveyor - Roller Medium Press Medium Conveyor - Screw Heavy Pump - Bore Light Crusher - Cone Medium Pump - Centrifugal Medium Crusher - Jaw Severe Pump - Positive displacement Heavy Crusher - Rotary Medium Pump - Slurry Severe Crusher - Vertical impact Medium Re-pulper Severe Debarker Medium Rotary table Heavy Dryer Severe Sander Heavy Dust collector Medium Saw - Bandsaw Severe Edger Medium Saw - Circular Medium Fan - Axial (Damped) Medium Separator Severe Fan - Axial (Un-damped) Severe Shredder Severe Fan - Centrifugal (Damped) Medium Slicer Light Fan - Centrifugal (Un-damped) Severe Tumbler Heavy Note: 3 The above table is intended as a guide only. Individual machine and motor characteristics will determine the actual start current and start time requirements. Duty category definition - Example Category Continuous operation Bypassed operation Light duty AC 53a: 3-10: 50-10 AC 53b: 3-10: 350 Medium duty AC 53a: 3.5-15: 50-10 AC 53b: 3.5-15: 345 Heavy duty AC 53a: 4-20: 50-10 AC 53b: 4-20: 340 Severe duty AC 53a: 4.5-30: 50-10 AC 53b: 4.5-30: 330 Example 1 Continuous operation Example 2 Bypassed operation AC 53a: 3-10: 50-10 AC 53b: 3-10: 350 Start condition Start condition 3 = 3 x FLC 10 = 10 seconds 3 = 3 x FLC 10 = 10 seconds Duty cycle Time between ramps 50 = Ratio of ON/OFF time 50 % 10 = Operating cycles per hour 350 = 350 seconds For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3-3 Soft starters PCS series to 75 kW PCS overview The PCS is a compact, simple to use soft starter product designed for 3 phase motors with ratings of up to 45 kW (3 wire) and 75 kW (6 wire). Unlike competing compact soft starter products, the PCS controls all three phases to the motor, thereby further extending its application possibilities and minimising thermal stresses on the motor. 3 The basic PCS soft starter features built-in electronic motor protection with adjustable trip class together with a number of other motor and system protection functions. It also has a built-in bypass contactor, thus providing very low watts loss, smaller footprint dimensions, suitability for high density motor control panels and minimising installed cost. Current limit The current limit start mode is used when it is necessary to The multiple starting and stopping modes offered by the PCS limit the maximum starting current. as standard make it suitable for a large variety of industrial applications. The current limit setting can be adjusted to provide 150 %, 250 %, 350 % or 450 % of full load amps during start. The The PCS is currently available in 2 voltage ranges, 200…480 V AC start time is also user adjustable from 2 to 30 seconds. (stocked by NHP) and 200…600 V AC (available on indent basis) and Note: If the motor is not up to speed after the selected time are suitable for connection to 50 or 60 Hz supply systems. elapses, the PCS will transition to full voltage. Current limit Motor starting PCS soft starters provide the user a selection of starting and stopping modes as standard. The ability to select and tailor the starting format ensures the full benefits of soft starting can be achieved in any industrial motor starting application. Standard starting modes Timed voltage ramp The timed voltage ramp soft start mode offered by the PCS has the most general application. User adjustments for initial torque and start ramp time allow the PCS to be configured for a variety of applications. The initial torque can be adjusted from 15 % to 65 % of locked rotor torque. The start ramp time can be adjusted from 2 to 30 seconds. Kickstart The kickstart function is intended for use on machines that present a high frictional starting characteristic. It provides a current pulse of 450 % FLC over a user adjustable period of 0 to 1.5 seconds, allowing the motor to develop the additional starting torque required to get the load moving. Kickstart 3-4 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft starters PCS series to 75 kW Standard stopping modes Soft Stop The soft stop function can be used to extend the stopping time of the motor and load. When enabled, the ramp down time can be set to either once, twice or three times the start ramp time setting. The motor will stop when the output voltage from the PCS reaches the point where the load torque is greater than the motor torque. Starter over-temperature protection The PCS monitors the temperature of its power circuits (SCRs) by means of internal thermistors. When the maximum rated temperature of the power assembly is reached, the PCS switches off and a temperature fault is indicated via LED. Shorted SCR protection Prior to every start, the PCS will check the integrity of its power assembly (SCRs) and load connections to the motor. If the PCS detects a shorted SCR and/or open circuit on its output, the start will be aborted. This prevents damage from phase imbalance. Fault indication In all cases, when a fault is detected the PCS will trip in order to protect the motor and illuminate a fault LED. The fault LED is flash coded, to assist the user in identifying the trip cause thus simplifying the troubleshooting process. 3 PCS set-up procedure PCS protection functions Quick and accurate set-up of the PCS is assured through a simple to use combination DIP switch selection panel and potentiometer. Electronic motor overload protection with user selectable trip class The PCS soft starter provides electronic motor overload protection with adjustable trip class and automatic or manual reset selectivity as standard making it extremely versatile. Where only basic soft start and motor protection functionality is required, the user need only set the motor full load current. The motor full load current is user adjusted via a potentiometer located on the front panel. Overload trip class (either OFF, 10, 15 or 20 seconds) and automatic or manual reset operation are DIP switch selectable. Note: PCS DIP switch selection panel The trip rating is 120 % of potentiometer setting. Phase sequence protection The PCS provides a user selectable (ON or OFF) phase sequence protection function as standard. When selected, the PCS will monitor the incoming phases before application of power to the motor. PCS optional extras Phase loss protection Auxiliary contacts The PCS provides phase loss protection as standard to ensure the motor will not attempt to start when there is a power phase missing. This protects the motor from burnout resulting from single phase starting conditions. The PCS provides 2 output relays as standard, one of which is programmable for instantaneous or up-to-speed operation. Should additional contacts be required, auxiliary contacts are available in a number of configurations. Open circuit output/open load protection Remote fault reset The PCS monitors the motor circuit to ensure the motor is connected throughout all phases of operation. Remote reset functionality can be achieved by installing a remote reset magnet onto the PCS. Reset magnets are available for all common AC control voltages. Phase imbalance protection The PCS provides phase imbalance protection as standard. During run it continually monitors motor current through its internal current transformers. To prevent motor over-heating or damage, the PCS will trip if the phase imbalance exceeds specified limits. Protective modules Protective modules containing metal oxide varistors (MOVs) and snubber networks can be installed to protect the PCS against line transients and electrical noise. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3-5 Soft starters PCS series - technical / ordering details Catalogue Number construction The PCS is available in a variety of different formats to ensure individual user requirements are totally satisfied. Models stocked by NHP are those listed below. All other combinations are available on indent, POA. Scan the QR code to view Motor Control & Drives brochures. PCS - 003 - 480V - 024 Product series designation C = 3 wire, 6 wire motor connection 3 Optional control supply Blank = 100 V AC - 240 V AC 024 = 24 V AC/DC Current rating (3 wire) Amps @ AC 53b:3.5-15:3585 Ambient temp. 50 °C, Altitude < 2000 m 003 = 3 Amps, 009 = 9 Amps, 016 = 16 Amps, 019 = 19 Amps, 025 = 25 Amps, 030 = 30 Amps, 037 = 37 Amps, 043 = 43 Amps, 060 = 60 Amps, 085 = 85 Amps Three phase supply voltage 480V = 200 V AC - 480 V AC 600V = 200 V AC - 600 V AC (Indent POA) Ordering details Ratings at 3.5 x FLC, 15 seconds 1) Max. motor FLC 3 Wire 6 Wire (A) (A) Standard Cat. No. PCS-003-480V 24 V AC/DC Control Cat. No. Price $ 890.00 PCS-003-480V-024V 3 5.1 Dimensions (mm) Overload 3) setting range (A) Height Width Depth 1…3 140 45 100 9 15 3…9 140 45 100 PCS-009-480V 910.00 PCS-009-480V-024V 16 27 5.3…16 140 45 100 PCS-016-480V 980.00 PCS-016-480V-024V 19 32 6.3…19 140 45 100 PCS-019-480V 1060.00 PCS-019-480V-024V 25 43 8.3…25 140 45 100 PCS-025-480V 1230.00 PCS-025-480V-024V 30 51 10…30 140 45 100 PCS-030-480V 1690.00 PCS-030-480V-024V 37 64 12.3…37 140 45 100 PCS-037-480V 2020.00 PCS-037-480V-024V 43 74 14.3…43 206 72 130 PCS-043-480V 2190.00 PCS-043-480V-024V 60 103 20…60 206 72 130 PCS-060-480V 2600.00 PCS-060-480V-024V 85 147 28.3…85 206 72 130 PCS-085-480V 3190.00 PCS-085-480V-024V Optional extras Auxiliary contacts Connection modules Protective modules Remote Reset Magnets Cooling fan Cat. No. 1 N/O contact PCS-PA-10 2 N/O contacts PCS-PA-20 1 N/C contact PCS-PA-01 1 N/O & 1 N/C contact PCS-PA-11 Connects PCS-003…019 to CA 7-9...23 PCS-23-CI23 Connects PCS-025…037 to CA 7-30...37 PCS-37-CI37 Connects PCS-003…025 to KT 7-25 S series breaker PCS-25S-CC25 480 V version suits all PCS models to 37 Amps PCP-064-480V 480 V version suits all PCS models 43 to 85 Amps PCP-147-480V 600 V version suits all PCS models to 37 Amps PCP-064-600V 600 V version for all models 43 to 85 Amps PCP-147-600V Suits all PCS models ) CMR7...V 2 ) Refer to PCS catalogue for starts/hour information. ) Standard voltages 110 to 240 V AC 50/60 Hz. 3 ) When using the PCS in 6 wire mode, the overload current must be set to 58 % of the motor FLC. E.g. A 50 Amp motor in 6 wire 1 2 Price Schedule ‘A3’ Opt. extras - Price Schedule ‘B4’ 3-6 Price $ Suits PCS models to 37 Amps (Supplied as standard with PCS models 43 to 135 Amps) Notes: Price $ PCV-064 mode would use a PCS-030-480 V and the overload current setting would be set to 29 Amps. PCS starters are also available in enclosed format. Refer NHP for details. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft starters CSX Series to 110 kW CSX overview The CSX is a compact soft starter intended for use with 3 phase motors ranging from 7.5 to 110 kW at 400 V AC. Designed with the ‘first time’ soft start user in mind, the CSX incorporates a number of unique features aimed specifically at simplifying the installation and commissioning processes while also significantly reducing installed cost. In order to achieve this the CSX is provided with Equi-Vec™ balanced vector control technology and in-built bypass contactor. Internal Bypass Contactor In operation, the CSX provides smooth acceleration and deceleration of the motor and connected load, thereby minimising the electrical and mechanical stresses that would otherwise be encountered through the use of electromechanical motor starting methods. Equi-Vec™ technology Equi-Vec™ balanced vector control is state-of-the-art technology developed to enhance the performance of 2 phase soft start controllers. By balancing the current vectors during motor starting, the CSX is able to provide 3 phase like performance while maintaining the commercial and mechanical advantages normally associated with compact soft starter technology. In-built bypass contactor CSX-007-V4-C1 3 Standard stopping modes Timed voltage ramp soft stop During soft stop, the CSX gradually decreases output voltage over a user selected ramp time enabling driven machines to be stopped gently. This is of particular advantage in applications where machinery and/or product are adversely affected by sudden stopping. Examples include pumps and conveyors. Time voltage ramp soft stop To further reduce installation complexity and cost the CSX is provided with an in-built bypass contactor as standard. This eliminates the need for purchase and installation of an external bypass contactor and/or the need to force ventilate the enclosure. Standard starting modes Timed voltage ramp soft start The timed voltage ramp start mode is ideally suited to those applications that exhibit a variable start torque requirement. It allows the user to program an initial start voltage and start ramp time to ensure electrical and mechanical stresses are minimised irrespective of motor loading. Notes: The soft stop feature can be disabled by selecting a ‘0’ stop time. The soft start and soft stop ramp times are independently adjustable. Protection features The CSX also offers an essential level of protection against; Q Power circuit faults Q Supply frequency faults Q Communications failure faults Catalogue Number construction CSX - 030 - V4 - C1 Control supply voltage C1 = 110-240 V AC or 380-440 V AC C2 = 24 V AC/V DC (indent) CSX set-up procedure Quick and accurate set-up of the CSX is as simple as setting two rotary switches to deliver your preferred soft starting performance. For those applications that can benefit from soft stop, an additional rotary switch is provided. Three phase supply voltage V4 = 200-440 V AC V6 = 200-575 V AC Nominal motor kW rating @ 400 V AC E.g. 007 = 7.5 kW, 110 = 110 kW For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3-7 Soft starters CSX Series - technical / ordering details Optional accessories Remote operator The RCM-02 is an IP 54 rated remote operator / display unit that allows the user to control and monitor CSX operations from a remote location. Note: The RCM-02 connects to the CSX via the optional interface module PIM-RZ-01. Fieldbus connectivity A selection of fieldbus protocol gateways is available for the CSX thereby enabling connection to your preferred communication network. Pump application interface 3 The pump application interface connects to the side of the CSX soft starter and provides enhanced functionality in pumping applications. Features include; Low pressure input, high pressure input, low water level input, a PT100 input and common fault relay. The digital inputs are assignable to normally open or normally closed whilst the PT100 input offers selectable trip temperature. RCM-02 Ordering details Current ratings based on 10 starts/hour equally spaced, 45 ºC, 3 wire motor connection. Light duty Medium duty Heavy duty Dimensions (mm) Standard 4 x FLC, 3 x FLC, 3.5 x FLC, Cat. No. 20 sec Height Width Depth 10 sec 15 sec Price $ 24 V AC/DC Control Cat. No. 22 18 16 203 98 163 CSX-007-V4-C1 980.00 CSX-007-V4-C2 42 34 29 203 98 163 CSX-015-V4-C1 1180.00 CSX-015-V4-C2 51 42 35 203 98 163 CSX-018-V4-C1 1270.00 CSX-018-V4-C2 57 46 38 203 98 163 CSX-022-V4-C1 1370.00 CSX-022-V4-C2 60 57 47 203 98 163 CSX-030-V4-C1 1630.00 CSX-030-V4-C2 84 68 57 215 145 191 CSX-037-V4-C1 1700.00 CSX-037-V4-C2 96 77 63 215 145 191 CSX-045-V4-C1 1990.00 CSX-045-V4-C2 100 100 82 215 145 191 CSX-055-V4-C1 2120.00 CSX-055-V4-C2 161 127 103 240 202 212 CSX-075-V4-C1 2360.00 CSX-075-V4-C2 190 151 123 240 202 212 CSX-090-V4-C1 2870.00 CSX-090-V4-C2 200 175 143 240 202 212 CSX-110-V4-C1 3180.00 CSX-110-V4-C2 Optional extras Cat. No. Finger guards for models 075-110 9950350300A Price $ Price $ Fast acting semiconductor fuses (400 V AC applications, 3 required per starter) For model CSX-007 170M1314 For model CSX-015 170M1317 For models CSX-018 and CSX-022 170M1318 For model CSX-030 170M1319 For models CSX-037 to CSX-055 170M1321 For model CSX-075 170M1322 For models CSX-090 and CSX-110 170M3022 Semiconductor fuse holders (1 holder per fuse) For 170M1314 to 170M1322 170H1007 For 170M3022 170H3003 Fieldbus communications modules DeviceNet PIM-DN-01 Modbus PIM-MB-01 Profibus PIM-PB-01 Pump Application interface PIM-PA-01 Remote operator panel - CSX Remote operator/fault display unit RCM-02 - Remote operator interface module Price Schedule ‘B3’ 3-8 PIM-RZ-01 CSX soft starters are also available in enclosed format. Consult your nearest NHP office for pricing and availability. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft starters CSXi Series to 110 kW CSXi overview The CSXi is a compact closed loop controlled current soft starter intended for use with 3 phase motors ranging from 7.5 to 110 kW at 400 V AC. Designed with the ‘first time’ soft start user in mind, the CSXi incorporates a number of unique features aimed specifically at simplifying the installation and commissioning processes while also significantly reducing installed cost. In order to achieve this the CSXi is provided with Equi-Vec™ balanced vector control technology, a comprehensive array of motor and system protection features including in-built bypass contactor and in-built thermal overload with adjustable trip class, all as standard. 3 CSXi-007-V4-C1 Standard starting modes In operation, the CSXi provides smooth acceleration and deceleration of the motor and connected load, thereby minimising the electrical and mechanical stresses that would otherwise be encountered through the use of electromechanical motor starting methods. Constant current/current limit soft start The constant current start mode is ideally suited to highly inertial applications. Due to the nature of this starting mode highly inertial loads are brought up to speed in the shortest time possible, thereby minimising thermal stresses on the motor. Constant current Equi-Vec™ technology Equi-Vec™ balanced vector control is state-of-the-art technology developed to enhance the performance of 2 phase soft start controllers. By balancing the current vectors during motor starting, the CSXi is able to provide 3 phase like performance while maintaining the commercial and mechanical advantages normally associated with compact soft starter technology. In-built motor & system protection The CSXi provides a comprehensive array of motor and system protection features to further satisfy the most demanding of industrial motor control applications. This eliminates the need to purchase/install additional devices, thus acting to reduce installed cost. In-built protection features are summarised as follows; Q Q Q Q Q Q Q Q Q Q Motor overload (adjustable thermal model) Phase loss / imbalance Excess start time Phase sequence / rotation Motor thermistor input Power circuit fault (shorted SCR, supply fault) Supply frequency Communications failure Trip contact LED healthy / fault indicators Timed current ramp soft start The timed current ramp start mode allows the user to set minimum starting current, maximum starting current and a start ramp time. This method of starting is proven in applications that present a variable starting torque requirement, for example a conveyor that at times may start fully loaded and at other times will be lightly loaded, or to extend the start time of loads that easily break away. Current ramp In-built bypass contactor To further reduce installation complexity and cost the CSXi is provided with in-built bypass contactor as standard. This eliminates the need for external bypass contactors and/or the need to force ventilate enclosures. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3-9 Soft starters CSXi Series to 110 kW Standard stopping modes Excess start time protection Timed voltage ramp soft stop The CSXi will trip if the starting time exceeds the motor’s safe starting time characteristics, ensuring the motor is not subjected to high currents for an excessive period of time. This feature will also ensure the load is not jammed or too large at start up. During soft stop, the CSXi gradually decreases output voltage over a user selected ramp time enabling driven machines to be stopped gently. This is of particular advantage in applications where machinery and or product can be adversely affected by sudden stopping. Examples include pumps and conveyors. Supply frequency error Notes: The soft stop feature can be disabled by selecting a ‘0’ stop time. The soft start and soft stop ramp times are independently adjustable. 3 Soft stop The supply frequency during start and run may vary under some conditions including generator power situations. The CSXi monitors supply frequency to ensure that it is not operating outside its design parameters thus preventing damage to itself and the motor. Phase sequence protection Phase sequence protection is of particular advantage in applications that are rotation direction sensitive such as pumps, compressors etc. The CSXi will monitor the incoming phase rotation before application of power to the motor to prevent incorrect rotation of the motor. This feature is user configurable to fwd or any phase sequence application. Communications failure Protection features further explained Electronic motor overload protection with user adjustable motor thermal model. The CSXi soft starter provides built-in motor overload protection with adjustable thermal model as standard. The thermal model allows the user to select the tripping curve which most closely resembles the thermal withstand curve of the connected motor. This eliminates nuisance motor overload tripping, while maximising machine up-time and plant productivity. User adjustable Motor FLC and thermal model via rotary switches located on the front panel. Motor thermistor protection In order to further enhance motor protection, the CSXi provides an input for direct connection of your motor thermistors. Automated plants utilise the communications features of the CSXi. Connection integrity is vital to maintain control and protection of the motor. The CSXi monitors the communications link to maintain supervisory control and displays a fault when a break occurs. CSXi Set-up Although the CSXi offers broad functionality, set-up is a simple process. A series of clearly labelled rotary switches is provided to ensure accurate and repeatable settings are easily made. Simply rotate these to the desired position (no need for a user manual) and you’re ready to go. Fault & status information Fault and status information is provided by on-board ‘flash coded’ LEDs. In addition, the RCM-02 remote operator is available for those who may require/benefit from remote control and monitoring. Catalogue Number construction Phase imbalance protection The CSXi offers phase imbalance protection as standard. During both start and run, the CSXi monitors motor current through its internal current transformers. In order to prevent motor damage, burn out or over heating, the CSXi will trip if an imbalance exceeds specified limits or a phase loss occurs. Power circuit protection Prior to the application of power to the motor but following a start command, the CSXi monitors its line and load connection and the integrity of its SCRs. Should any abnormality be detected, the CSXi will trip thus ensuring the motor is not compromised. 3 - 10 CSXi - 030 - V4 - C1 Control supply voltage C1 = 110-240 V AC or 380-440 V AC C2 = 24 V AC/V DC (indent) Three phase supply voltage V4 = 200-440 V AC V6 = 200-575 V AC Nominal motor kW rating @ 400 V AC E.g. 007 = 7.5 kW, 110 = 110 kW For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft starters CSXi Series - technical / ordering details Optional accessories Remote operator The RCM-02 is an IP 54 rated remote operator / display unit that allows the user to control and monitor CSXi operations from a remote location. Note: The RCM-02 connects to the CSXi via the optional interface module PIM-RZ-01. Fieldbus connectivity A selection of Fieldbus protocol gateways is available for the CSXi thereby enabling connection to your preferred communication network. Pump application interface The pump application interface connects to the side of the CSXi soft starter and provides enhanced functionality in pumping applications. Features include; Low pressure input, high pressure input, low water level input, a PT100 input and common fault relay. The digital inputs are assignable to normally open or normally closed whilst the PT100 input offers selectable trip temperature. 3 RCM-02 Ordering details Current ratings based on 10 starts/hour equally spaced, 45 ºC, 3 wire motor connection. Light duty Medium duty Heavy duty Dimensions (mm) Standard 4 x FLC, 3 x FLC, 3.5 x FLC, Cat. No. 20 sec Height Width Depth 10 sec 15 sec Price $ 24 V AC/DC Control Cat. No. 18 18 16 203 98 163 CSXI-007-V4-C1 1470.00 CSXI-007-V4-C2 34 34 29 203 98 163 CSXI-015-V4-C1 1870.00 CSXI-015-V4-C2 42 42 35 203 98 163 CSXI-018-V4-C1 2050.00 CSXI-018-V4-C2 48 46 38 203 98 163 CSXI-022-V4-C1 2120.00 CSXI-022-V4-C2 60 57 47 203 98 163 CSXI-030-V4-C1 2350.00 CSXI-030-V4-C2 75 68 57 215 145 191 CSXI-037-V4-C1 2620.00 CSXI-037-V4-C2 85 77 63 215 145 191 CSXI-045-V4-C1 2830.00 CSXI-045-V4-C2 100 100 82 215 145 191 CSXI-055-V4-C1 2980.00 CSXI-055-V4-C2 140 127 103 240 202 212 CSXI-075-V4-C1 3150.00 CSXI-075-V4-C2 170 151 123 240 202 212 CSXI-090-V4-C1 4050.00 CSXI-090-V4-C2 200 175 143 240 202 212 CSXI-110-V4-C1 4260.00 CSXI-110-V4-C2 Optional extras Cat. No. Finger guards for models 075-110 9950350300A Price $ Price $ Fast acting semiconductor fuses (400 V AC applications, 3 required per starter) For model CSXi-007 170M1314 For model CSXi-015 170M1317 For models CSXi-018 and CSXi-022 170M1318 For model CSXi-030 170M1319 For models CSXi-037 to CSXi-055 170M1321 For model CSXi-075 170M1322 For models CSXi-090 and CSXi-110 170M3022 Semiconductor fuse holders (1 holder per fuse) For 170M1314 to 170M1322 170H1007 For 170M3022 170H3003 Fieldbus communications modules DeviceNet PIM-DN-01 Modbus PIM-MB-01 Profibus PIM-PB-01 PIM-PA-01 Pump Application interface Remote operator panel - Price Schedule ‘B3’ Remote operator/fault display unit RCM-02 Remote operator interface module PIM-RZ-01 CSXi Soft starters are also available in enclosed format. Consult your nearest NHP office for pricing and availability. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 11 Refer catalogue EMX3 Soft starters EMX3 for motors to 1500 kW @ 400 V AC and 690 V AC Constant current Overview The EMX3 is an advanced digital soft start solution for motors from 7.5 kW to 1500 kW. EMX3 soft starters provide a complete range of motor and system protection features and have been designed for reliable performance in the most demanding installation situations. Motor starting 3 The EMX3 puts you truly in control of motor starting. Depending on your application requirements you can select between the two best soft start control methods. For applications requiring precise control of motor start current EMX3 offers a choice of Constant Current or Current Ramp start modes. Or for superior control over acceleration or deceleration choose XLR-8 Adaptive Acceleration Control. Standard starting modes XLR-8 XLR-8 adaptive acceleration control is a new intelligent motor control technique developed by AuCom. In an XLR-8 soft start, the EMX3 adjusts the current in order to start the motor within a specified time and using a selected acceleration profile. Every application has a particular starting profile, based on characteristics of the load and motor. XLR-8 offers three different starting profiles, to suit the requirements of different applications. Selecting an XLR-8 profile that matches the inherent profile of the application can help smooth out acceleration across the full start time. Selecting a dramatically different XLR-8 profile can somewhat neutralise the inherent profile. For example, using a late cubic profile to start an early cubic application will result in a more linear behaviour. Timed current ramp Current ramp soft starting raises the current from a specified starting level to a maximum limit, over an extended period of time. Current ramp starting can be useful for applications where: Q The load can vary between starts (for example a conveyor which may start loaded or unloaded). Set the initial current to a level that will start the motor with a light load, and the current limit at a level that will start the motor with a heavy load. Q The load breaks away easily, but starting time needs to be extended (for example a centrifugal pump where pipeline pressure needs to build up slowly). Q The electricity supply is limited (for example a generator set), and a slower application of load will allow greater time for the supply to respond. Current ramp XLR-8 Adaptive acceleration control 4 100 90 80 1 70 60 2 50 3 40 30 20 10 0 Time XLR-8 start profile 1 Early acceleration 2 Constant acceleration 3 Late acceleration 4 Start ramp time Kickstart Kickstart provides a short boost of extra torque at the beginning of a start, and can be used in conjunction with current ramp or constant current starting. Kickstart can be useful to help start loads that require high breakaway torque but then accelerate easily (for example flywheel loads such as presses). Kickstart Constant current Constant current is the traditional form of soft starting, which raises the current from zero to a specified level and keeps the current stable at that level until the motor has accelerated. Constant current starting is ideal for applications where the start current must be kept below a particular level. 3 - 12 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft starters EMX3 series overview Standard stopping modes XLR-8 Adaptive deceleration control In an XLR-8 soft stop, the EMX3 controls the current in order to stop the motor within a specified time and using a selected deceleration profile. XLR-8 can be useful in extending the stopping time of low interia loads. Every application has a particular stopping profile, based on characteristics of the load and the motor. XLR-8 offers three different stopping profiles. Brake When brake is selected, the EMX3 uses DC injection to slow the motor. Braking XLR-8 Adaptive deceleration control 4 100 3 90 80 3 70 2 60 50 40 1 30 20 10 0 Time Choose the XLR-8 profile that best matches your application requirements. XLR-8 stop profile: 1 Early deceleration 2 Constant deceleration 3 Late deceleration 4 Stop time TVR soft stop Timed voltage ramp reduces the voltage to the motor gradually over a defined time. The load may continue to run after the stop ramp is complete. Timed voltage ramp stopping can be useful for applications where the stop time needs to be extended, or to avoid transients on generator set supplies. The EMX3 braking: • Does not require the use of a DC brake contactor • Controls all three phases so that the braking currents and associated heating is evenly distributed through the motor. Braking has two stages: 1. Pre-brake: provides an intermediate level of braking to slow motor speed to a point where full brake can be operated successfully (approximately 70 % speed). 2. Full brake: brake provides maximum braking torque but is ineffective at speeds greater than approximately 70 %. Standard protection Motor thermal model The EMX3 will verify whether the motor has sufficient thermal capacity for a successful start. The soft starter compares the motor’s temperature rise from the last motor start and only operates if the motor is cool enough to start successfully. Excess start time Excess start time is the maximum time the EMX3 will attempt to start the motor. If the motor does not reach full speed within the programmed limit, the starter will trip indicating a stalled condition. TVR Soft Stop Electronic shearpin protection With electronic shearpin or instantaneous overcurrent protection the EMX3 can be configured to trip if the average current of all three phases exceeds a specified level while the motor is running. This would usually occur in a ‘stall’ or ‘locked rotor’ condition. Undercurrent The soft starter can be configured to trip if the average current of all three phases drops below a specified level while the motor is running. This undercurrent or under-load is usually indicative of a broken coupling between the motor and driven machine, a broken conveyer belt, loss of product or a dry pump. Mains frequency The EMX3 monitors mains frequency throughout operation, and can be configured to trip if the frequency varies beyond a specified tolerance. Phase sequence This feature selects which phase sequences the soft starter will allow at a start. During its pre-start checks, the starter examines the sequence of the phases at its input terminals and trips if the actual sequence does not match the selected option. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 13 Soft starters EMX3 series overview Current imbalance Quick start set-up The EMX3 can be configured to trip if the currents on the three phases vary from each other by more than a specified amount. The imbalance is calculated as the difference between the highest and lowest currents on all three phases, as a percentage of the highest current. The EMX3 has been designed for ease of use, and the userfriendly menu is no exception. A quick setup guide helps you configure the starter for common applications by suggesting a typical setting, which you can then fine tune to suit your needs. Real language in real time Auxiliary input trip 3 Auxiliary input trip allows the connection of external fault detection devices, such as low pressure or no flow detectors, vibration sensors, etc. The EMX3 gives real-language feedback messages instead of the usual alarm codes. With real-time metering displays and a 99-place event log recording time-stamped details of operation and performance, it has never been easier to track how your motor is behaving. Motor thermistor input The EMX3 has provisions for motor thermistor input and is able to detect excessive temperature in the motor windings generally caused by a stall or from inadequate ventilation. Remote mounting keypad Control pushbuttons, fault and status information available from the EMX3 can be brought out to the cubicle door via the remote mounting keypad option. RS 485 failure The EMX3’s serial link is provided with a user adjustable time-out function which will trip if the maximum allowable period of RS 485 serial inactivity has been exceeded. Optional protection functions Ground fault The optional Ground fault/ RTD card allows the user to configure the soft starter to trip if ground fault exceeds a specified level while the motor is running. Ground fault is a dynamic trip based on phase current measurements every half-cycle. RTD inputs The optional Ground fault/RTD card allows the user to connect up to six PT100 RTD directly to the EMX3. This feature enables the EMX3 to measure the temperature of the RTDs and trip if overheating is detected. Trip levels are user programmed. EMX3 specialist features Graphical display In many cases we’ve done away with language altogether, using real-time graphs of motor operating performance and current to quickly and clearly illustrate exactly how your motor is performing. 3 - 14 Metering and monitoring EMX3 delivers an extensive range of information to replace an additional powermeter. These include motor temperature, current data, motor power, last start information, date and time, performance graph, SCR conduction, trip log and the userprogrammable screen. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft starters EMX3 series overview Simulations Adjustable power terminals The EMX3 simulation functions let you test the soft starter’s operation, external control circuits and associated equipment without connecting the soft starter to line voltage or a motor. The EMX3 has three simulation modes: Run simulation: simulates a motor starting, running and stopping to ensure correct installation. Protection simulation: simulates activation of each protection mechanism to confirm correct protection response. Signaling simulation: simulates output signaling. The bus bars on models EMX3-0360C ~ EMX3-1600C can be adjusted for top and bottom input and output giving four options to ease installation. This flexibility allows you optimisation of your switchboard layout. In addition, internally bypassed models EMX3-0350B EMX3-1000B have input and output busbars at both the top and the bottom of the unit. The busbars do not need to be adjusted. 3 Emergency run operation Emergency Run is controlled by a two wire circuit connected to Input A (terminals C53-C54). Closing Input A causes the EMX3 to run the motor and ignore user specified trip conditions. This is useful when the cost of lost production out-weighs the potential cost of further equipment damage. Optional accessories Unique wiring loom Using the EMX3’s unique and flexible cable ways, cables can be efficiently organised for wiring from either the top, left or from below. Optional accessories for the EMX3 include the following: Q Communication modules enabling the soft starter to be controlled by protocols such as DeviceNet™, ProfiBus® and Modbus RTU Q USB module enables communication between your PC and EMX3 via Win-Master software. Win-Master is available free of charge. Q I/O cards giving an added 2 x inputs, 3 x relay outputs, 1 x analogue input and 1 x analogue output. Q RTD and Ground fault card providing 6 x PT100 RTD inputs 1 x ground fault input Expansion input/ output card Removable terminal blocks Installation is easy with plug-in control terminal blocks, simply unplug each block, complete the wiring and re-insert the block. 6 way RTD and ground fault protection card Communication modules Catalogue Number construction The EMX3 is available with a variety of options and formats to ensure individual user’s requirements are met. Models stocked by NHP are listed on the following 2 pages and all other combinations are available on indent, POA. EMX3 – 0255 B – V4 – C1 – H Keypad H = Keypad fitted Control voltage C1 = 110-220 V AC & 230-440 V AC C2 = 24 V AC/DC Three phase supply voltage V4 = 200 V AC – 440 V AC V7 = 400 V AC – 690 V AC (indent) Bypass B = Internally Bypassed C = Non-bypassed (indent) Nominal current rating Product series designation For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 15 Soft Starters EMX3 maximum motor FLC ratings 2) 3 wire - 400 / 415 V AC applications 1) Light Medium Heavy Severe Duty Duty Duty Duty 3 x FLC, 3.5 x FLC, 4 x FLC, 4.5 x FLC, Frame 10 sec 15 sec 20 sec 30 sec size 110-440 V AC Control Standard Model 3) Cat. No. Price $ 24 V AC/DC Control Variant Model Cat. No. Price $ AC 53b: Internal bypass contactor 3 23 A 20 A 17 A 15 A G1B 43 A 37 A 31 A 26 A G1B 50 A 44 A 37 A 30 A G1B 53 A 53 A 46 A 37 A G1B 76 A 64 A 55 A 47 A G1B 97 A 82 A 69 A 58 A G1B 100 A 88 A 74 A 61 A G1B 105 A 105 A 95 A 78 A G1B 145 A 123 A 106 A 90 A G2B 170 A 145 A 121 A 97 A G2B 200 A 189 A 160 A 134 A G2B 220 A 210 A 178 A 148 A G2B 255 A 231 A 201 A 176 A G3B 350 A 306 A 266 A 230 A G3B 425 A 371 A 321 A 276 A G3B 500 A 445 A 383 A 326 A G4B 580 A 492 A 425 A 364 A G4B 700 A 592 A 512 A 438 A G4B 820 A 705 A 606 A 516 A G4B 920 A 804 A 684 A 571 A G4B 1000 A 936 A 796 A 664 A G4B EMX3-0023B-V4-C1-H EMX3-0043B-V4-C1-H EMX3-0050B-V4-C1-H EMX3-0053B-V4-C1-H EMX3-0076B-V4-C1-H EMX3-0097B-V4-C1-H EMX3-0100B-V4-C1-H EMX3-0105B-V4-C1-H EMX3-0145B-V4-C1-H EMX3-0170B-V4-C1-H EMX3-0200B-V4-C1-H EMX3-0220B-V4-C1-H EMX3-0255B-V4-C1-H EMX3-0350B-V4-C1-H EMX3-0425B-V4-C1-H EMX3-0500B-V4-C1-H EMX3-0580B-V4-C1-H EMX3-0700B-V4-C1-H EMX3-0820B-V4-C1-H EMX3-0920B-V4-C1-H EMX3-1000B-V4-C1-H 2550.00 2870.00 3120.00 3510.00 3690.00 4260.00 4610.00 4910.00 5610.00 5980.00 7160.00 7430.00 8650.00 11710.00 12720.00 14320.00 15700.00 16510.00 20620.00 23830.00 25650.00 EMX3-0023B-V4-C2-H EMX3-0043B-V4-C2-H EMX3-0050B-V4-C2-H EMX3-0053B-V4-C2-H EMX3-0076B-V4-C2-H EMX3-0097B-V4-C2-H EMX3-0100B-V4-C2-H EMX3-0105B-V4-C2-H EMX3-0145B-V4-C2-H EMX3-0170B-V4-C2-H EMX3-0200B-V4-C2-H EMX3-0220B-V4-C2-H EMX3-0255B-V4-C2-H EMX3-0350B-V4-C2-H EMX3-0425B-V4-C2-H EMX3-0500B-V4-C2-H EMX3-0580B-V4-C2-H EMX3-0700B-V4-C2-H EMX3-0820B-V4-C2-H EMX3-0920B-V4-C2-H EMX3-1000B-V4-C2-H 8130.00 9180.00 9320.00 12040.00 16020.00 16980.00 20790.00 23390.00 24910.00 28410.00 31190.00 EMX3-0255C-V4-C2-H EMX3-0360C-V4-C2-H EMX3-0380C-V4-C2-H EMX3-0430C-V4-C2-H EMX3-0620C-V4-C2-H EMX3-0650C-V4-C2-H EMX3-0790C-V4-C2-H EMX3-0930C-V4-C2-H EMX3-1200C-V4-C2-H EMX3-1410C-V4-C2-H EMX3-1600C-V4-C2-H AC 53a: Continous operation (no internal bypass) 4) 255 A 222 A 195 A 171 A G3C 360 A 351 A 303 A 259 A G4C 380 A 380 A 348 A 292 A G4C 430 A 413 A 355 A 301 A G4C 620 A 614 A 515 A 419 A G4C 650 A 629 A 532 A 437 A G4C 790 A 790 A 694 A 567 A G4C 930 A 930 A 800 A 644 A G4C 1200 A 1200 A 1135 A 983 A G5C 1410 A 1355 A 1187 A 1023 A G5C 1600 A 1600 A 1433 A 1227 A G5C Notes: EMX3-0255C-V4-C1-H EMX3-0360C-V4-C1-H EMX3-0380C-V4-C1-H EMX3-0430C-V4-C1-H EMX3-0620C-V4-C1-H EMX3-0650C-V4-C1-H EMX3-0790C-V4-C1-H EMX3-0930C-V4-C1-H EMX3-1200C-V4-C1-H EMX3-1410C-V4-C1-H EMX3-1600C-V4-C1-H ) ) Representative image to aid soft starter product selection, does not constitute complete power circuit. Ratings for models EMX3-0023B to EMX3-0053B are based on 10 starts per hour, equally spaced, 40 ºC ambient. Ratings for models EMX3-0076B to EMX3-1000B and EMX3-0255C to EMX3-1600C are based on 6 starts per hour equally spaced, 40 ºC ambient. 3 ) Standard models with internal bypass contactor (EMX3-xxxxB) are generally stocked. 4 ) Intended for use in well vented enclosures and / or with external bypass contactor. Particularly suited to applications with high overload trip class (>trip class 10) and those that may experience transient overload conditions as part of normal run time operation. For application and duty category definitions refer to page 3 - 3. For 690 V AC applications refer to pages 3 - 18 and 3 - 19. 1 2 Price Schedule ‘B3’ 3 - 16 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft Starters EMX3 maximum motor FLC ratings 2) 6 wire - 400 / 415 V AC applications 1) Scan the QR code to view EMX3 brochure. Light Medium Heavy Severe Duty Duty Duty Duty 3 x FLC, 3.5 x FLC, 4 x FLC, 4.5 x FLC, Frame 10 sec 15 sec 20 sec 30 sec size 110-440 V AC Control Standard Model 3) Cat. No. Price $ 24 V AC/DC Control Variant Model Cat. No. Price $ AC 53b: Internal bypass contactor 34 A 30 A 26 A 22 A G1B 64 A 59 A 51 A 44 A G1B 75 A 66 A 55 A 45 A G1B 79 A 79 A 69 A 55 A G1B 114 A 96 A 83 A 70 A G1B 145 A 123 A 104 A 87 A G1B 150 A 132 A 112 A 82 A G1B 157 A 157 A 143 A 117 A G1B 217 A 184 A 159 A 136 A G2B 255 A 217 A 181 A 146 A G2B 300 A 283 A 241 A 200 A G2B 330 A 315 A 268 A 223 A G2B 382 A 346 A 302 A 264 A G3B 525 A 459 A 399 A 345 A G3B 638 A 557 A 482 A 414 A G3B 750 A 668 A 575 A 490 A G4B 870 A 738 A 637 A 546 A G4B 1050 A 889 A 768 A 658 A G4B 1230 A 1058 A 910 A 774 A G4B 1380 A 1206 A 1026 A 857 A G4B 1500 A 1404 A 1194 A 997 A G4B EMX3-0023B-V4-C1-H EMX3-0043B-V4-C1-H EMX3-0050B-V4-C1-H EMX3-0053B-V4-C1-H EMX3-0076B-V4-C1-H EMX3-0097B-V4-C1-H EMX3-0100B-V4-C1-H EMX3-0105B-V4-C1-H EMX3-0145B-V4-C1-H EMX3-0170B-V4-C1-H EMX3-0200B-V4-C1-H EMX3-0220B-V4-C1-H EMX3-0255B-V4-C1-H EMX3-0350B-V4-C1-H EMX3-0425B-V4-C1-H EMX3-0500B-V4-C1-H EMX3-0580B-V4-C1-H EMX3-0700B-V4-C1-H EMX3-0820B-V4-C1-H EMX3-0920B-V4-C1-H EMX3-1000B-V4-C1-H 2550.00 2870.00 3120.00 3510.00 3690.00 4260.00 4610.00 4910.00 5610.00 5980.00 7160.00 7430.00 8650.00 11710.00 12720.00 14320.00 15700.00 16510.00 20620.00 23830.00 25650.00 EMX3-0023B-V4-C2-H EMX3-0043B-V4-C2-H EMX3-0050B-V4-C2-H EMX3-0053B-V4-C2-H EMX3-0076B-V4-C2-H EMX3-0097B-V4-C2-H EMX3-0100B-V4-C2-H EMX3-0105B-V4-C2-H EMX3-0145B-V4-C2-H EMX3-0170B-V4-C2-H EMX3-0200B-V4-C2-H EMX3-0220B-V4-C2-H EMX3-0255B-V4-C2-H EMX3-0350B-V4-C2-H EMX3-0425B-V4-C2-H EMX3-0500B-V4-C2-H EMX3-0580B-V4-C2-H EMX3-0700B-V4-C2-H EMX3-0820B-V4-C2-H EMX3-0920B-V4-C2-H EMX3-1000B-V4-C2-H 8130.00 9180.00 9320.00 12040.00 16020.00 16980.00 20790.00 23390.00 24910.00 28410.00 31190.00 EMX3-0255C-V4-C2-H EMX3-0360C-V4-C2-H EMX3-0380C-V4-C2-H EMX3-0430C-V4-C2-H EMX3-0620C-V4-C2-H EMX3-0650C-V4-C2-H EMX3-0790C-V4-C2-H EMX3-0930C-V4-C2-H EMX3-1200C-V4-C2-H EMX3-1410C-V4-C2-H EMX3-1600C-V4-C2-H 3 AC 53a: Continous operation (no internal bypass) 4) 382 A 346 A 302 A 264 A G3C 540 A 540 A 465 A 395 A G4C 570 A 570 A 539 A 449 A G4C 645 A 645 A 552 A 464 A G4C 930 A 930 A 810 A 651 A G4C 975 A 975 A 842 A 683 A G4C 1185 A 1185 A 1071 A 868 A G4C 1395 A 1395 A 1244 A 992 A G4C 1800 A 1800 A 1800 A 1606 A G5C 2115 A 2115 A 1979 A 1671 A G5C 2400 A 2400 A 2400 A 2030 A G5C Notes: EMX3-0255C-V4-C1-H EMX3-0360C-V4-C1-H EMX3-0380C-V4-C1-H EMX3-0430C-V4-C1-H EMX3-0620C-V4-C1-H EMX3-0650C-V4-C1-H EMX3-0790C-V4-C1-H EMX3-0930C-V4-C1-H EMX3-1200C-V4-C1-H EMX3-1410C-V4-C1-H EMX3-1600C-V4-C1-H ) ) Representative image to aid soft starter product selection, does not constitute complete power circuit. Ratings for models EMX3-0023B to EMX3-0053B are based on 10 starts per hour, equally spaced, 40 ºC ambient. Ratings for models EMX3-0076B to EMX3-1000B and EMX3-0255C to EMX3-1600C are based on 6 starts per hour equally spaced, 40 ºC ambient. 3 ) Standard models with internal bypass contactor (EMX3-xxxxB) are generally stocked. 4 ) Intended for use in well vented enclosures and / or with external bypass contactor. Particularly suited to applications with high overload trip class (>trip class 10) and those that may experience transient overload conditions as part of normal run time operation. For application and duty category definitions refer to page 3 - 3. For 690 V AC applications refer to pages 3 - 18 and 3 - 19. 1 2 Price Schedule ‘B3’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 17 Soft Starters EMX3 maximum motor FLC ratings 2) 3 wire - 690 V AC applications 1) Light Medium Heavy Severe Duty Duty Duty Duty 3 x FLC, 3.5 x FLC, 4 x FLC, 4.5 x FLC, Frame 10 sec 15 sec 20 sec 30 sec size 110-440 V AC Control Standard Model 3) Cat. No. Price $ 24 V AC/DC Control Variant Model Cat. No. Price $ AC 53b: Internal bypass contactor 3 23 A 20 A 17 A 15 A G1B 43 A 37 A 31 A 26 A G1B 50 A 44 A 37 A 30 A G1B 53 A 53 A 46 A 37 A G1B 76 A 64 A 55 A 47 A G1B 97 A 82 A 69 A 58 A G1B 100 A 88 A 74 A 61 A G1B 105 A 105 A 95 A 78 A G1B 145 A 123 A 106 A 90 A G2B 170 A 145 A 121 A 97 A G2B 200 A 189 A 160 A 134 A G2B 220 A 210 A 178 A 148 A G2B 255 A 231 A 201 A 176 A G3B 350 A 306 A 266 A 230 A G3B 425 A 371 A 321 A 276 A G3B 500 A 445 A 383 A 326 A G4B 580 A 492 A 425 A 364 A G4B 700 A 592 A 512 A 438 A G4B 820 A 705 A 606 A 516 A G4B 920 A 804 A 684 A 571 A G4B 1000 A 936 A 796 A 664 A G4B EMX3-0023B-V7-C1-H EMX3-0043B-V7-C1-H EMX3-0050B-V7-C1-H EMX3-0053B-V7-C1-H EMX3-0076B-V7-C1-H EMX3-0097B-V7-C1-H EMX3-0100B-V7-C1-H EMX3-0105B-V7-C1-H EMX3-0145B-V7-C1-H EMX3-0170B-V7-C1-H EMX3-0200B-V7-C1-H EMX3-0220B-V7-C1-H EMX3-0255B-V7-C1-H EMX3-0350B-V7-C1-H EMX3-0425B-V7-C1-H EMX3-0500B-V7-C1-H EMX3-0580B-V7-C1-H EMX3-0700B-V7-C1-H EMX3-0820B-V7-C1-H EMX3-0920B-V7-C1-H EMX3-1000B-V7-C1-H 2860.00 3210.00 3500.00 3910.00 4110.00 4740.00 5130.00 5490.00 6250.00 6640.00 7980.00 8300.00 9580.00 12610.00 12720.00 15580.00 17110.00 18350.00 22990.00 26190.00 28010.00 EMX3-0023B-V7-C2-H EMX3-0043B-V7-C2-H EMX3-0050B-V7-C2-H EMX3-0053B-V7-C2-H EMX3-0076B-V7-C2-H EMX3-0097B-V7-C2-H EMX3-0100B-V7-C2-H EMX3-0105B-V7-C2-H EMX3-0145B-V7-C2-H EMX3-0170B-V7-C2-H EMX3-0200B-V7-C2-H EMX3-0220B-V7-C2-H EMX3-0255B-V7-C2-H EMX3-0350B-V7-C2-H EMX3-0425B-V7-C2-H EMX3-0500B-V7-C2-H EMX3-0580B-V7-C2-H EMX3-0700B-V7-C2-H EMX3-0820B-V7-C2-H EMX3-0920B-V7-C2-H EMX3-1000B-V7-C2-H 9010.00 10090.00 10220.00 13110.00 17280.00 18400.00 22630.00 25750.00 28530.00 32810.00 36460.00 EMX3-0255C-V7-C2-H EMX3-0360C-V7-C2-H EMX3-0380C-V7-C2-H EMX3-0430C-V7-C2-H EMX3-0620C-V7-C2-H EMX3-0650C-V7-C2-H EMX3-0790C-V7-C2-H EMX3-0930C-V7-C2-H EMX3-1200C-V7-C2-H EMX3-1410C-V7-C2-H EMX3-1600C-V7-C2-H AC 53a: Continous operation (no internal bypass) 4) 255 A 222 A 195 A 171 A G3C 360 A 351 A 303 A 259 A G4C 380 A 380 A 348 A 292 A G4C 430 A 413 A 355 A 301 A G4C 620 A 614 A 515 A 419 A G4C 650 A 629 A 532 A 437 A G4C 790 A 790 A 694 A 567 A G4C 930 A 930 A 800 A 644 A G4C 1200 A 1200 A 1135 A 983 A G5C 1410 A 1355 A 1187 A 1023 A G5C 1600 A 1600 A 1433 A 1227 A G5C Notes: 2 ) Price Schedule ‘B3’ 3 - 18 EMX3-0255C-V7-C1-H EMX3-0360C-V7-C1-H EMX3-0380C-V7-C1-H EMX3-0430C-V7-C1-H EMX3-0620C-V7-C1-H EMX3-0650C-V7-C1-H EMX3-0790C-V7-C1-H EMX3-0930C-V7-C1-H EMX3-1200C-V7-C1-H EMX3-1410C-V7-C1-H EMX3-1600C-V7-C1-H ) Representative image to aid soft starter product selection, does not constitute complete power circuit. Ratings for models EMX3-0023B to EMX3-0053B are based on 10 starts per hour, equally spaced, 40 ºC ambient. Ratings for models EMX3-0076B to EMX3-1000B and EMX3-0255C to EMX3-1600C are based on 6 starts per hour equally spaced, 40 ºC ambient. 3 ) Standard models with internal bypass contactor (EMX3-xxxxB) are generally stocked. 4 ) Intended for use in well vented enclosures and / or with external bypass contactor. Particularly suited to applications with high overload trip class (>trip class 10) and those that may experience transient overload conditions as part of normal run time operation. For application and duty category definitions refer to page 3 - 3. For 400/415 V AC applications refer to pages 3 - 16 and 3 - 17. 1 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft Starters EMX3 maximum motor FLC ratings 2) 6 wire - 690 V AC applications 1) Scan the QR code to view EMX3 brochure. Light Medium Heavy Severe Duty Duty Duty Duty 3 x FLC, 3.5 x FLC, 4 x FLC, 4.5 x FLC, Frame 10 sec 15 sec 20 sec 30 sec size 110-440 V AC Control Standard Model 3) Cat. No. Price $ 24 V AC/DC Control Variant Model Cat. No. Price $ AC 53b: Internal bypass contactor 34 A 30 A 26 A 22 A G1B 64 A 59 A 51 A 44 A G1B 75 A 66 A 55 A 45 A G1B 79 A 79 A 69 A 55 A G1B 114 A 96 A 83 A 70 A G1B 145 A 123 A 104 A 87 A G1B 150 A 132 A 112 A 82 A G1B 157 A 157 A 143 A 117 A G1B 217 A 184 A 159 A 136 A G2B 255 A 217 A 181 A 146 A G2B 300 A 283 A 241 A 200 A G2B 330 A 315 A 268 A 223 A G2B 382 A 346 A 302 A 264 A G3B 525 A 459 A 399 A 345 A G3B 638 A 557 A 482 A 414 A G3B 750 A 668 A 575 A 490 A G4B 870 A 738 A 637 A 546 A G4B 1050 A 889 A 768 A 658 A G4B 1230 A 1058 A 910 A 774 A G4B 1380 A 1206 A 1026 A 857 A G4B 1500 A 1404 A 1194 A 997 A G4B EMX3-0023B-V7-C1-H EMX3-0043B-V7-C1-H EMX3-0050B-V7-C1-H EMX3-0053B-V7-C1-H EMX3-0076B-V7-C1-H EMX3-0097B-V7-C1-H EMX3-0100B-V7-C1-H EMX3-0105B-V7-C1-H EMX3-0145B-V7-C1-H EMX3-0170B-V7-C1-H EMX3-0200B-V7-C1-H EMX3-0220B-V7-C1-H EMX3-0255B-V7-C1-H EMX3-0350B-V7-C1-H EMX3-0425B-V7-C1-H EMX3-0500B-V7-C1-H EMX3-0580B-V7-C1-H EMX3-0700B-V7-C1-H EMX3-0820B-V7-C1-H EMX3-0920B-V7-C1-H EMX3-1000B-V7-C1-H 2860.00 3210.00 3500.00 3910.00 4110.00 4740.00 5130.00 5490.00 6250.00 6640.00 7980.00 8300.00 9580.00 12610.00 12720.00 15580.00 17110.00 18350.00 22990.00 26190.00 28010.00 EMX3-0023B-V7-C2-H EMX3-0043B-V7-C2-H EMX3-0050B-V7-C2-H EMX3-0053B-V7-C2-H EMX3-0076B-V7-C2-H EMX3-0097B-V7-C2-H EMX3-0100B-V7-C2-H EMX3-0105B-V7-C2-H EMX3-0145B-V7-C2-H EMX3-0170B-V7-C2-H EMX3-0200B-V7-C2-H EMX3-0220B-V7-C2-H EMX3-0255B-V7-C2-H EMX3-0350B-V7-C2-H EMX3-0425B-V7-C2-H EMX3-0500B-V7-C2-H EMX3-0580B-V7-C2-H EMX3-0700B-V7-C2-H EMX3-0820B-V7-C2-H EMX3-0920B-V7-C2-H EMX3-1000B-V7-C2-H 9010.00 10090.00 10220.00 13110.00 17280.00 18400.00 22630.00 25750.00 28530.00 32810.00 36460.00 EMX3-0255C-V7-C2-H EMX3-0360C-V7-C2-H EMX3-0380C-V7-C2-H EMX3-0430C-V7-C2-H EMX3-0620C-V7-C2-H EMX3-0650C-V7-C2-H EMX3-0790C-V7-C2-H EMX3-0930C-V7-C2-H EMX3-1200C-V7-C2-H EMX3-1410C-V7-C2-H EMX3-1600C-V7-C2-H 3 AC 53a: Continous operation (no internal bypass) 4) 382 A 346 A 302 A 264 A G3C 540 A 540 A 465 A 395 A G4C 570 A 570 A 539 A 449 A G4C 645 A 645 A 552 A 464 A G4C 930 A 930 A 810 A 651 A G4C 975 A 975 A 842 A 683 A G4C 1185 A 1185 A 1071 A 868 A G4C 1395 A 1395 A 1244 A 992 A G4C 1800 A 1800 A 1800 A 1606 A G5C 2115 A 2115 A 1979 A 1671 A G5C 2400 A 2400 A 2400 A 2030 A G5C Notes: EMX3-0255C-V7-C1-H EMX3-0360C-V7-C1-H EMX3-0380C-V7-C1-H EMX3-0430C-V7-C1-H EMX3-0620C-V7-C1-H EMX3-0650C-V7-C1-H EMX3-0790C-V7-C1-H EMX3-0930C-V7-C1-H EMX3-1200C-V7-C1-H EMX3-1410C-V7-C1-H EMX3-1600C-V7-C1-H ) ) Representative image to aid soft starter product selection, does not constitute complete power circuit. Ratings for models EMX3-0023B to EMX3-0053B are based on 10 starts per hour, equally spaced, 40 ºC ambient. Ratings for models EMX3-0076B to EMX3-1000B and EMX3-0255C to EMX3-1600C are based on 6 starts per hour equally spaced, 40 ºC ambient. 3 ) Standard models with internal bypass contactor (EMX3-xxxxB) are generally stocked. 4 ) Intended for use in well vented enclosures and / or with external bypass contactor. Particularly suited to applications with high overload trip class (>trip class 10) and those that may experience transient overload conditions as part of normal run time operation. For application and duty category definitions refer to page 3 - 3. For 400/415 V AC applications refer to pages 3 - 16 and 3 - 17. 1 2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 19 Soft starters EMX3 series technical / ordering details Optional extras Cat. No. Price $ 1 Fast acting semiconductor fuses (400/415 V AC applications) ) 3 For model EMX3-0023B (3 required) 170M1314 For model EMX3-0043B (3 required) 170M1316 For models EMX3-0050B and EMX3-0053B (3 required) 170M1318 For model EMX3-0076B (3 required) 170M1319 For models EMX3-0097B to EMX3-0145B (3 required) 170M1321 For models EMX3-0170B to EMX3-0220B (3 required) 170M2621 For model EMX3-0255B (3 required) 170M2621 For model EMX3-0350B (3 required) 170M5011 For model EMX3-0425B (3 required) 170M6011 For model EMX3-0500B (6 required) 170M6008 2) For model EMX3-0580B (3 required) 170M6013 For model EMX3-0700B (3 required) 170M5015 For model EMX3-0820B (3 required) 170M5017 For model EMX3-0920B (3 required) 170M6017 For model EMX3-1000B (3 required) 170M6018 For model EMX3-0255C (3 required) 170M2621 For model EMX3-0360C (3 required) 170M6010 For models EMX3-0380C and EMX3-0430C (3 required) 170M6011 For models EMX3-0620C and EMX3-0650C (3 required) 170M6015 For model EMX3-0790C (3 required) 170M6017 For model EMX3-0930C (3 required) 170M6019 For model EMX3-1200C to EMX3-1600C (3 required) Refer NHP 2 ) Semiconductor fuse holders (1 holder per fuse) For 170M1314 to 170M2621 170H1007 For 170M5011 170H3003 For 170M5015 to 170M6017 170H3004 For 170M6018 and 170M6019 Refer NHP Fieldbus communication modules Modbus (RTU) PIM-MB-01 Modbus (TCP) PIM-MT-01 DeviceNet PIM-DN-01 ProfiBus PIM-PB-01 ProfiNet PIM-PN-01 Ethernet IP PIM-EI-01 USB module (EMX3 to PC via USB) PIM-USB-01 Input / Output cards 2 x digital inputs, 3 x relay outputs, 1 x analogue input 995-04803-00 Additional protection card RTD and ground fault card 995-08133-00 Keypad (Spare part) Finger guards (for models 0145B-0220B) 3) 995-04938-00 Note: 995-06348-00 ) Two parallel connected fuses required per phase. ) Fuse selection is based on a 400 % FLC start for 20 seconds in conjunction with standard published starts per hour, duty cycle, 40 °C ambient temperature and up to 1000 m altitude. For installations operating outside these conditions, consult NHP. 1 2 3 - 20 995-04804-00 Keypad remote mount kit For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Soft starters EMX3 series technical / ordering details Dimensions (mm) and weights (kg) Frame A B C D E kg EMX3-0023B to EMX3-0053B G1B 156 124 295 278 192 3.2 EMX3-0076B G1B 156 124 295 278 223 3.5 EMX3-0097B to EMX3-0105B G1B 156 124 295 278 223 4.8 EMX3-0145B to EMX3-0220B G2B 282 250 438 380 250 16 EMX3-0255B G3B 424 376 440 392 298 26 EMX3-0350B to EMX3-0425B G3B 424 376 440 392 298 30.2 EMX3-0500B to EMX3-0580B G4B 433 320 640 600 297 49.5 EMX3-0700B to EMX3-1000B G4B 433 640 640 600 297 60 EMX3-0255C G3C 390 320 417 400 284 25 EMX3-0360C to EMX3-0430C G4C 430 320 698 522 302 50.5 EMX3-0620C to EMX3-0930C G4C 430 320 698 522 302 53.5 EMX3-1200C to EMX3-1600C G5C 574 500 750 727 361 140 Note: 3 For EMX3-0145B to EMX3-1600C, dimensions A and C are the unit footprint. Busbars are not included as this dimension will vary with busbar configuration. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 21 Soft starters EMX3 series specifications EMX3 specifications Supply Supply voltage EMX3-XXXX-V4-XX-X 200 V AC ~ 440 V AC (± 10 %) Supply voltage EMX3-XXXX-V7-XX-X 380 V AC ~ 690 V AC (± 10 %) (earthed star supply system only) Electronics supply EMX3-XXXX-XX-C1-X 110 ~ 220 V AC and 220 ~ 440 V AC (+ 10 % / - 15 %) (standard) EMX3-XXXX-XX-C2-X 45 Hz (50 Hz supply) to 66 Hz (60 Hz supply) Supply frequency 3 24 V AC AC/24 V DC (± 20 %) (optional) Control inputs Start (Terminals C23, C24) N/O, Active 24 V DC, 8 mA approx. Stop (Terminals C31, C32) N/C, Active 24 V DC, 8 mA approx. Reset (Terminals C41, C42) N/O or N/C, Active 24 V DC, 8 mA approx. Programmable input A (Terminals C53, C54) N/O or N/C, Active 24 V DC, 8 mA approx. Programmable input B (Terminals C63, C64) N/O or N/C, Active 24 V DC, 8 mA approx. Outputs N/O 10 A at 250 V AC resistive Run output 5 A at 250 V AC, AC 15 pf 0.3 Programmable output A (Terminals 13, 14) N/O 10 A at 250 V AC resistive 5 A at 250 V AC, AC 15 pf 0.3 Programmable output B (Terminals 31, 32, 34) C/O 10 A at 250 V AC resistive 5 A at 250 V AC, AC 15 pf 0.3 Programmable output C (Terminals 41, 42, 44) C/O 10 A at 250 V AC resistive 5 A at 250 V AC, AC 15 pf 0.3 Analogue output (Terminals B10, B11) 0-20 mA or 4-20 mA Sundry Enclosure rating EMX3-0023B ~ EMX3-0105B IP 20 Enclosure rating EMX3-0145B ~ EMX3-1000B IP 00 Enclosure rating EMX3-0255C ~ EMX3-1600C IP 00 Rated insulation voltage to earth 600 V AC Rated impulse withstand voltage 4 kV Form designation Bypassed or continuous, semiconductor motor starter Form 1 EMC emissions IEC 60947-4-2 Class B Operating temperatures 40 ºC, max 60 ºC with derating Relative humidity 5 % to 95 % Standards / approvals 3 - 22 CE IEC 60947-4-2 UL/C-UL UL 508 CCC GB 14048-6 C IEC 60947-4-2 Marine Lloyds Marine No 1 Specification RoHS Compliant with EU Directive 2002/95/EC For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives Product Selection Guide NHP offer a wide range of Variable Speed Drives (VSD) to cover the many applications and control methods available. The selection table below provides a summary of the ratings and features of each product in the NHP range. Identify the ratings and features required for your application and select the VSD that is right for you. For additional information see the relevant pages as indicated at the bottom of the table. If further assistance is required in selecting a VSD to suit your specific application, please contact your nearest NHP sales office. 3 SINUS N (NANO) SINUS M (MICRO) SINUS PENTA Rated power 0.4-2.2 kW 0.4-22 kW 2.2-2010 kW Supply voltage 200-230 V 200-230 V / 380-480 V 380-690 V Cat. No. Variable / constant torque Load type Light (120 %) Heavy (175 %) Standard (140 %) Strong (200 %) Ambient temperature 50 °C 50 °C 1) Enclosure protection IP 20 6) IP 20 / IP 54 EMC Filter Internal Second environment 2) Internal First environment Display Internal Second environment 2) 7 segment LED 4 line backlit 7) LCD display Removable keypad – Keypad potentiometer – – Overload capacity 150 % for 60 sec 120 % / 140 % / 175 % / 200 % for 60 sec 3) 150 % Up to 200 % for 120 sec IFD = V/f Sensorless Vector Control IFD = V/f VTC - vector torque control (open or closed loop) FOC = Field oriented control Analogue inputs 2 x analogue inputs 0-10 V DC and 4-20 mA 3 x configurable inputs 4) +10 V DC or 0 (4) - 20 mA Analogue outputs 0-10 V DC 3 x configurable outputs 4) +10 V DC or 0 (4) - 20 mA Starting torque Control type Logic inputs 5 programmable 8 programmable 3 fixed 4) 5 prog (multiples possible) Logic outputs 1 multifunction relay 1 prog logic 1 prog relay 2 prog logic 2 prog relay 2 prog logic Communication RS 485/Modbus 5), Profibus®, Ethernet, Interbus, DeviceNet™, Canopen, ControlNet Dynamic brake module 8) – Page reference Notes: ) ) 3 ) 4 ) 5 ) 1 2 Internal Internal 1) PID function Encoder feedback RS 485/Modbus 5), Profibus®, DeviceNet™, Interbus, ControlNet, Ethernet – 3 - 21 Dependant on size. First environment (Class B) filter as option. Corresponding to selected rating. Expandable. Standard protocol. – 3 - 22 3 - 24 ) Enclosed versions available to IP 54. ) Remote mount keypad option. 8 ) Requires external resistor. 6 7 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 23 Variable speed drives SINUS Nano The SINUS Nano is an economical and compact micro drive by Santerno that incorporates both Sensorless Vector Control and V/f control. The digital keypad is included as standard and navigation through the menu structure is straightforward with its easy to use menu structure. The SINUS Nano is suitable for both constant and variable torque applications with automatic and manual torque boost for high inertia applications. A dwell function is included as standard which makes the drive suitable for hoisting applications. Furthermore, the SINUS Nano includes a motor auto-tuning function to ensure the drive is optimised for high performance motor operation. The SINUS Nano conforms to EMC requirements for C-Tick first environment. Features at a glance: 3 Q Q Q Q Q Q Q Q Q Capacity 0.4 kW to 2.2 kW Single phase 200-230 V AC supply 2 control modes – V/f and sensorless vector control Front panel stop/start and potentiometer controls IP 20 enclosure Motor auto-tuning for increased performance PID functionality Integral EMC input filter complies with C-Tick first environment (domestic & industrial) Fixed height and depth throughout the range Options: Q Q Q Input/output chokes Communications card RS 485/Modbus Communications device for DeviceNet™/Profibus®/Ethernet/Interbus/Canopen/ControlNet including programming cable and software Standard Specifications: Input voltage: Control system: Overload current rating: Protection functions: Frequency setting: Protection: Environmental: Single phase 200-240 V AC Inverter frequency drive (V/f) and sensorless vector control 150 % overload capacity (for 1 minute) Over/undervoltage, overcurrent, inverter overheat, motor overheat, I/O phase loss, external I/O input fault, speed command loss, hardware fault, CPU error, overload, external device fault External potentiometer, digital keypad, communication (Modbus), 0-10 V DC, 0-20 mA. IP 20 -10 to +50 °C operational, -20 to +65 °C storage, 0 to 90 % RH non-condensing Ordering details SINUS Nano Motor rating (kW) Rated Supply Dimensions (mm) output D W current (A) voltage (V) H 143 79 143 2.5 -- Watt Loss (w) Cat. No. 7 SN 0001 2S XB K2 0.75 5 143 79 143 25 SN 0002 2S XB K2 1.5 8 143 156 143 48 SN 0003 2S XB K2 2.2 12 143 156 143 73 SN 0005 2S XB K2 0.4 Price $ Price Schedule ‘M5’ 3 - 24 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives SINUS Micro The SINUS Micro is a fully featured compact drive with the smallest sized footprint in its class. With Sensorless Vector Control and V/f control for both constant and variable torque applications, plus the addition of manual and automatic torque boost, this drive is suitable for all types of applications. Extremely easy to use, the SINUS Micro is compatible with the Remote Drive software and complies with EMC requirements. Q Features at a glance: Q Q Q Q Q Q Q Q Q Capacity 0.4 kW to 22 kW Single/three phase 200-230 V AC and three phase 380-480 V AC supply V/f and sensorless vector control modes Built-in RS 485/Modbus IP 20 enclosure Motor auto-tuning for increased performance PID functionality Fire mode for HVAC applications Internal fan control Q Integral EMC input filter complies with C-Tick second environment (industrial) optional first environment EMC filter available Integrated braking unit Options: Q Q Q Q Q EMC filters for first environment (domestic) Input/output chokes Braking resistors Remote mounting keypad Full range of high-level communications available 3 Standard Specifications: Input voltage: Control system: Overload current rating: Dynamic braking: Protection functions: Frequency setting: Protection: Environmental: Single/three phase 200-240 V AC and three phase 380-480 V AC Inverter frequency drive (V/f) and sensorless vector control 150 % overload capacity (for 1 minute) 20 % without brake resistor. Average 150 % with external brake resistor Over/undervoltage, overcurrent, inverter overheat, motor overheat, external I/O input fault, I/O phase loss, speed command loss, ground fault current detection, output phase open, fan trip, hardware fault, overload, communication error Digital keypad, communication - Modbus/Fieldbus (option) 0-10 V DC, 0-20 mA. IP 20 -10 to +50 °C operational, -20 to +65 °C storage, 0 to 90 % RH non-condensing Ordering details SINUS Micro 0.75 Rated Supply output current (A) voltage (V) 2.5 200-240, 1/3 phase 5 200-240, 1/3 phase 1.5 8 2.2 12 4.0 17 5.5 24 7.5 32 11 46 15 60 18.5 74 22 88 0.4 0.75 Motor rating (kW) 0.4 Price Schedule ‘M5’ Dimensions (mm) Watt Loss (w) Cat. No. H W D 128 70 130 13 SM 0001 2ST BA2K2 128 70 130 28 SM 0002 2ST BA2K2 200-240, 1/3 phase 128 100 200-240, 1/3 phase 128 140 130 18 SM 0003 2ST BA2K2 155 56 SM 0005 2ST BA2K2 200-240, 1/3 phase 128 140 200-240, 1/3 phase 220 180 155 106 SM 0007 2ST BA2K2 170 73 SM 0011 2ST BA2K2 200-240, 1/3 phase 220 180 200-240, 1/3 phase 320 235 170 70 SM 0014 2ST BA2K2 190 290 SM 0017 2ST BA2K2 200-240, 1/3 phase 320 235 200-240, 1/3 phase 410 260 190 683 SM 0020 2ST BA2K2 210 759 SM 0025 2ST BA2K2 210 799 SM 0030 2ST BA2K2 1.25 200-240, 1/3 phase 410 260 128 70 380-480, 3 phase 130 9 SM 0001 4T BA2K2 2.5 380-480, 3 phase 128 70 130 22 SM 0002 4T BA2K2 1.5 4 380-480, 3 phase 128 100 130 32 SM 0003 4T BA2K2 2.2 6 380-480, 3 phase 128 140 155 47 SM 0005 4T BA2K2 4.0 9 380-480, 3 phase 128 140 155 94 SM 0007 4T BA2K2 5.5 12 380-480, 3 phase 220 180 170 84 SM 0011 4T BA2K2 7.5 16 380-480, 3 phase 220 180 170 113 SM 0014 4T BA2K2 11 24 380-480, 3 phase 320 235 190 293 SM 0017 4T BA2K2 15 30 380-480, 3 phase 320 235 190 608 SM 0020 4T BA2K2 18.5 39 380-480, 3 phase 410 260 210 759 SM 0025 4T BA2K2 380-480, 3 phase 410 260 210 1019 SM 0030 4T BA2K2 22 45 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au Price $ GST not included 3 - 25 Variable speed drives SINUS Nano and Micro options First environment EMC filter If compliance to the first environment is required (domestic installations) then an additional foot print EMC filter is required when using the SINUS Micro. The SINUS Nano incorporates a first environment (domestic installation) and second environment (industrial installation) EMC filter as standard. To suit Inverter Model Current Dimensions (mm) range SM-XXXX-XXX-BA2K2 Rating (A) L W H Cat. No. Price $ SM 77 0001-0002 2ST 40 5 175 SME00022ST 3 0003 2ST 12 177 108 40 SM SME00032ST 0005-0007 2ST 20 177 147 45 SM SME00072ST 0011 2ST 30 266 185 60 SM SME00112ST 0014 2ST 50 270 190 60 SM SME00142ST 0001-0002 4T 5 175 77 40 SM SME00024T 0003 4T 6 177 107 40 SM SME00034T 0005-0007 4T 11 177 147 45 SM SME00074T 0011-0014 4T 30 266 186 60 SM SME00144T Braking resistors The SINUS Micro incorporates an internal brake module which allows the connection of an external IP 55 brake resistor which may be required in applications where fast deceleration is required or where there is a high intertia load and avoids nuisance tripping caused by regeneration. Inverter Model SM-XXXX-XXXBA2K2 Resistor Specification Watts Resistance (W) (1) Dimensions (mm) L W H To suit range Brake resistor Cat. No. 0001 2ST 350 200 200 35 30 SM RE2644200 0002 2ST 350 100 200 35 30 SM RE2644100 0003 2ST 350 56 200 35 30 SM RE2643560 RE2643560 0005 2ST 350 56 200 35 30 SM 0007 2ST 350 56 200 35 30 SM RE2643560 RE3083500 0011 2ST 1100 15 320 95 30 SM 0014 2ST 1100 15 320 95 30 SM RE3083500 RE2644400 0001 4T 350 400 200 35 30 SM 0002 4T 350 400 200 35 30 SM RE2644400 RE2644200 0003 4T 350 200 200 35 30 SM 0005 4T 350 200 200 35 30 SM RE2644200 RE2644200 0007 4T 350 200 200 35 30 SM 0011 4T 550 75 195 68 13 SM RE3063750 30 SM RE3083500 0014 4T 1100 50 320 95 Additional options Description To suit range Cat. No. MODBUS/RS485 Communications card SN WW1420000 Door mount kit for remote keypad mounting SM SMDMK PC Software kit for use with Remote Drive (includes cable, USB/RS485 converter – Remote Drive software available from www.nhp.com.au/santerno) SN SM SPUSB Profibus® DP serial gateway 1) SN 2)/SM ZZ4600030 DeviceNet™ serial gateway 1) SN 2)/SM SNMDEVNT Ethernet serial gateway 1) SN 2)/SM SNMETHNT Interbus serial gateway 1) SN 2)/SM SNMINTBS CANOpen serial gateway 1) SN 2)/SM SNMCANOP ControlNet serial gateway 1) SN 2)/SM SNMCTLNT Price $ Price $ (includes IP 66 keypad, gasket, 3 m cable) Price Schedule ‘M5’ 3 - 26 Notes: ) 2 ) 1 Contact NHP for further information. WW1420000 required for fieldbus communication when using SINUS Nano. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Refer catalogue ESD-C Variable speed drives for AC motors Introduction to SINUS PENTA The SINUS PENTA is the latest fully featured drive to be released by Santerno of Italy. This model boasts an extensive range of features to allow easy adaptation to a wide variety of applications while being easy to use, with a 4 line alphanumeric display with all text in plain English. All drives feature a full metal enclosure to provide robustness to suit the demands of industrial environments. In addition the metal enclosure minimises radiated EMC. The full range of drives up to 1 MW, 415 V and 2 MW, 690 V contain internal EMC filters complying with C-Tick Second Environment (Class A). With the addition of a ferrite core, the standard drive is also suitable for use in the First Environment (Class B) up to frame size S50. Further flexibility is also achieved with the inclusion of an IP 54 version for sizes up to S30 (132 kW). The IP 54 drive is a stand-alone wall mounted device which can be expanded to include a choke and additional pushbuttons and switches. Features at a glance: Options (see pages 3 - 35 and 3 - 44) Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q Q EMC filter conforming to C-Tick first environment Q Dynamic braking resistors Q AC line choke Q Output choke Q Semiconductor fuses Q Keypad mounting kit Q I/O expansion cards Q Encoder cards Q PC software and cables Q Communication and fieldbus cards Q Harmonic filters Wide power and voltage range. 2.2-2010 kW, 380-690 V IP 20 and IP 54 standard solutions Selectable overload from 120 % to 200 % Built-in EMC filters to comply with for the entire range 3 year warranty Five built-in control types (see below) Regenerative/Active front end option 4 line alphanumeric display Extensive I/O configuration Fire mode solution to suit HVAC application Zero speed Fluxing (in VTC mode) Wide range of options available Integral brake chopper up to 132 kW ModBus RTU communications standard Optional fieldbus for all major protocols Cabinet solution available PC communication software with internet connectivity Extensive fault history record Safety stop function to IEC 61800-5-2 3 PENTA – Five integrated control functions The SINUS PENTA incorporates five built-in control functions to accommodate a wide range of applications. This allows the one product to be adapted to many types of control philosophies and therefore provide the best performance for your application. These include the following functions. IFD = Inverter Frequency Drive This function offers an adjustable V/f pattern for general purpose applications. VTC Open Loop = Vector Torque Control Open Loop Through Sensorless Vector Direct Torque Control, the VTC function allows for improved torque performance without the need for feedback. VTC Closed Loop = Vector Torque Control Closed Loop The VTC function allows for fast dynamic response through encoder feedback for high torque or demanding applications. FOC = Field Oriented Control FOC is the ultimate in vector speed control providing high accuracy through encoder feedback for high torque precision and a wide speed range. SYN = Synchronous This control function provides a vector function for the control of brushless synchronous permanent magnet motors. This provides high torque accuracy combined with energy efficiency. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 27 Variable speed drives for AC motors Introduction to SINUS PENTA User friendly interface The 4 line alphanumeric keypad provides clear plain English text messaging for monitoring, parameter configuration and fault annunciation making the SINUS PENTA extremely user friendly. To simplify local operation, the keypad incorporates dedicated keys for Start, Stop, direction of rotation, local/remote selection, jog and reset. These keys are in addition to the standard programming keys. Status monitoring is made easy with the use of 11 LEDs to indicate conditions such as run, alarm, direction of rotation and local control active. The keypad has built-in intelligence to enable parameters to be uploaded and downloaded directly from the keypad. 3 To simplify commissioning and parameters set-up, the drive has three selectable access levels. Basic level is designed for simple applications, advanced is for applications requiring additional flexibility and engineering for applications requiring full configuration. The accessible parameters are minimised to suit the control function used and the access level selected. This allows the drive to have as few as 30 parameters for basic application or as many as 500 parameters for the most sophisticated applications. Flexible connection The SINUS PENTA is designed for flexibility. This flexibility is incorporated into the extensive range of I/Os available. The SINUS PENTA incorporates as standard three programmable analogue inputs and outputs. Also included are eight digital inputs, two digital outputs and two relay outputs. Inputs are programmable with the ability for dual assignment for activation of two functions simultaneously. Outputs incorporate both timing and logic for added flexibility. In addition, option boards are available to extend the number of I/Os. Having flexible inputs and outputs allows the SINUS PENTA to easily adapt to a wide range of control solutions. Connectivity Connectivity to a PC is possible using the "Remote Drive" software, which offers tools for the control of the drive, trending functions, setting and storage of parameters and online monitoring. Remote Drive allows the added benefit of providing a remote communication service by using a simple internet connection. The remote drive software and chat line allows fast communication between the inverter’s user and our engineers. Extensive connectivity is achieved by the use of a wide range of communication interfaces available. The drive incorporates Modbus-RTU and RS 485 as standard and with the addition of an option board, which can be mounted within the drive, all the other major fieldbus protocols can be accommodated such as Profibus DP, DeviceNet, CanBus, Interbus, Ethernet and many more currently in development. Robust construction The SINUS PENTA range are designed for robustness to meet the demands of industrial applications. The complete series includes a full metal enclosure for durability. The robustness extends to the full system. With a high level of quality and reliability as well as strict adherence to international standards such as ISO 9001, Santerno is able to offer a three year warranty. This dependability provides the confidence that the drive can meet the challenge of demanding applications. IP 54 solution For many applications it is advantageous to install the drive directly on a machine, close to the motor, or on a wall. For this reason a higher enclosure protection is required. The SINUS PENTA is available in sizes up to 132 kW providing an economical and convenient solution. This solution is particularly suited to HVAC applications, irrigation, the food industry or applications requiring dispersed motor control. The robust IP 54 frame provides a removable gland plate, space to mount additional components if required and the ability to add additional controls to the front of the drive. For applications requiring the addition of a choke, a dedicated IP 54 option can be added to the drive construction. Enclosed systems By calling on the extensive range of options and products available an enclosed drive package can be tailored to suit the specific requirements of an application. The system can be customised to include options such as contactors, chokes, semiconductor fuses, dynamic braking solutions, communications options and many more. Please contact your NHP representative to discuss your specific requirements. 3 - 28 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives for AC motors Introduction to SINUS PENTA Engineered solutions For applications requiring more specialised solutions, Engineered systems can be developed. Solutions that are available include 12 or 18 pulse input configuration for reduced harmonic distortion and fully regenerative solutions to allow regenerated energy to be fed back to the supply. Special application software is also available to fulfill the requirements of specific applications such as multi-pump control, servo-diameters, axis control and positioning applications. These applications can be loaded into a standard SINUS PENTA drive. For further details on these specialised areas please contact NHP. EMC Requirements EMI (Electromagnetic Interference) is normally caused by commutations in many devices. The high frequency interference can affect the operation of other devices and can create noises in measurement and communication systems. All these combined effects can create unexpected breakdowns. Two areas can be affected by the above: immunity and emissions. 3 AS 61800-3 is the product-specific drives standard that defines both immunity and emission levels required for those devices designed to operate in different environments. The SINUS PENTA range is designed to operate under different conditions, therefore they are all provided with a strong immunity against RFI that allows them to be reliable in all environments. Furthermore the complete range of drives in the SINUS PENTA series are C-Tick approved with integral EMC filters and conform to category C3 for the Second Environment. With the addition of a ferrite core, the drives can comply to category C1 for the First Environment. To simplify installation of analogue signals screen terminations are also included as standard. Below are the AS 61800-3 2005 definitions on emission limits: (PDS = power drive system) First Environment Environment that includes domestic premises, or establishments directly connected without intermediate transformers to a low-voltage power supply network which supplies buildings used for domestic purposes. Second Environment Environment that includes all establishments than those directly connected to a low-voltage power supply network which supplies buildings used for domestic purposes. PDS of Category C1 PDS of rated voltage less than 1000 V, intended for use in the first environment. PDS of Category C2 PDS of rated voltage less than 1000 V, which is neither a plug-in service nor a movable device and, when used in the first environment, is intended to be installed and commissioned only by a professional. PDS of Category C3 PDS of rated voltage less than 1000 V, intended for use in the second environment. PDS of Category C4 PDS of rated voltage equal or above 1000 V, or rated current equal or above 400 A, or intended for use in complex systems in the second environment. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 29 Variable speed drives for AC motors Drive selection Selection of a SINUS PENTA variable drive system is extremely simple by following the steps shown below: Using the application overload table on section 3 - 28 identify your application which matches closest with those shown in the list. Once an application has been selected, identify the correct overload rating based on the location of the mark. If unsure, contact NHP. If two overload ratings are selected, choose the overload rating that best suits your application. Step 2 From the selection table on page 3 - 29, identify the column that contains the selected overload rating from step 1 and choose the 380-500 V AC drive model that matches or exceeds your motor full load current. OR From the selection table on page 3 - 40 use the same process to select your 660-690 V AC drive model. Step 3 For 380-500 V AC drives, based on your drive model selection from step 2 and using the table on page 3 - 30, identify the correct part number and price in either IP 20/00 or IP 54 (to 132 kW) models. OR For 660-690 V AC drives, use the table on page 3 - 40 to identify the correct part number and price in IP 20/00 models. Step 4 For 380-500 V AC drives, select optional input/output chokes on page 3 - 32 based on the drive size – e.g. SP0014, and available in IP 20 and IP 54 versions. For long cable runs and drives >S50, input and output chokes are recommended. OR For 575-690 V AC drives, select input/output chokes on page 3 - 41. Step 5 For 380-500 V AC drives, contact NHP for first environment EMC filters for use in domestic installations, input semiconductor fuses + accessories to protect the drive in the event of short circuit upstream of the drive on page 3 - 33. OR For 575-690 V AC drives and optional first environment filters and fuses + accessories, contact NHP. Step 1 3 Step 7 For 380-500 V AC and 575-690 V AC drives, select optional braking resistors and braking units (>S40) using the selection table on page 3 - 34 and then view technical details and pricing on table 3 - 35. Step 8 For all SINUS PENTA drives, refer to page 3 - 44 for details on options such as fieldbus communications, remote door mount kits, harmonic filters, etc. 3 - 30 Step 6 For additional information: • 380-500 V AC selection table including isolators, contactors, etc. on pages 3 - 36 to 3 - 39 • Multipump application page 3 - 42 • Regenerative application page 3 - 43 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives Typical application overload requirements Application Light Centrifuge Chipper D Compressor – screw (loaded) D Mill - roller D Crusher – rotary Crusher – vertical impact Debarker Drawplates Pulper D Pump – positive displacement/ submersible D D D Pump – slurry Drill D Dryer D D D Saw – band Saw – Circular Shears D Separator D Elevator D Extruder D D D D D D D D D D D D D Sander D D Shredder Slicer Spinner D Tumbler D Vibrating screen D Winding/Unwinding D Forming machine D D D Washer – industrial D D D D D D D D D D D 3 D D D D D Rotary table D Edger D Press Pump – centrifugal D D Planer Pump – bore Strong D Mixer D Crusher – jaw Grinder D Mill - hammer D Crusher – cone Fan – high pressure D Injection moulding – screw Mill – ball D Conveyor – screw Fan – centrifugal (undamped) Hydraulic power pack Palletiser D D Heavy D Injection moulding – hydraulic power pack D Conveyor – roller Fan – centrifugal (damped) Standard Paint stirrer Conveyor – belt Fan – axial (undamped) D D Compressor – piston (unloaded) Fan – axial (damped) Light Loom Compressor – piston (loaded) Dust collector D D D D D Application Hoist/crane D Calenders Compressor – screw (unloaded) Strong D Axis control Bottle washer Heavy D Agitator Atomiser Standard D D D D D D Light up to 120 % overload Standard up to 140 % overload Heavy up to 175 % overload Strong up to 200 % overload For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 31 Variable speed drives SINUS PENTA Range and selection Power Supply 380-415 V AC Size S05 1) 3 S12 1) S15 1) S20 1) S30 1) S41 S51 S60 S65 2) S75 2) Light Standard Light kW A 4.5 9 5.5 11.2 7.5 14.5 7.5 14.8 7.5 14.8 11 21 15 29 15 29 22 41 22 41 30 55 30 55 37 67 45 80 50 87 55 98 65 114 75 133 100 180 110 191 120 212 132 228 160 273 200 341 220 375 250 425 280 480 315 528 400 680 400 680 450 765 500 841 560 939 710 1200 900 1480 1000 1646 1170 1950 Cat. No. SP 0005 4TBA2K2 SP 0007 4TBA2K2 SP 0009 4TBA2K2 SP 0011 4TBA2K2 SP 0014 4TBA2K2 SP 0016 4TBA2K2 SP 0017 4TBA2K2 SP 0020 4TBA2K2 SP 0025 4TBA2K2 SP 0030 4TBA2K2 SP 0034 4TBA2K2 SP 0036 4TBA2K2 SP 0040 4TBA2K2 SP 0049 4TBA2K2 SP 0060 4TBA2K2 SP 0067 4TBA2K2 SP 0074 4TBA2K2 SP 0086 4TBA2K2 SP 0113 4TBA2K2 SP 0129 4TBA2K2 SP 0150 4TBA2K2 SP 0162 4TBA2K2 SP 0180 4TXA2KO SP 0202 4TXA2K0 SP 0217 4TXA2K0 SP 0260 4TXA2K0 SP 0313 4TXA2K0 SP 0367 4TXA2K0 SP 0402 4TXA2K0 SP 0457 4TXA2K0 SP 0524 4TXA2K0 SP 0598 4TXA2K0 SP 0748 4TXA2K0 SP 0831 4TXA2K0 SP 0964 4TXA2K0 SP 1130 4TXA2K0 SP 1296 4TXA2K0 up to 120 % overload up to 140 % overload Heavy Strong Standard kW A 4 8.4 4.5 9 5.5 11.2 7.5 14.8 7.5 14.8 9 18 11 21 15 29 18.5 35 22 41 25 46 30 55 30 55 37 67 45 80 55 98 65 114 75 133 90 159 100 180 110 191 132 228 150 264 160 273 220 375 250 425 280 480 315 528 400 680 400 680 450 765 500 841 560 939 630 1080 800 1334 900 1480 1100 1874 Heavy kW A 3 6.4 4 8.4 4.5 9 5.5 11.2 7.5 14.8 9 18 9 18 11 21 15 29 18.5 35 22 41 25 46 25 46 30 55 37 67 45 80 50 87 55 98 75 133 80 144 90 159 110 191 132 228 160 273 185 321 220 375 250 421 280 480 355 589 315 528 355 589 400 680 500 841 560 939 710 1200 800 1334 900 1480 P 0005 4 T Drive size Model Voltage rating 2 = 200-240 V 4 = 380-500 V 3) 5 = 500-575 V 6 = 575-690 V PENTA ) 3 Range S = SINUS 3) SB = SINUS BOX SC = SINUS CABINET Note: Power supply T = Three phase 3) S = Single phase C = DC Fed D = 12 Pulse input ) Available in IP 54 version ) Require input and output chokes 3 ) NHP standard model 1 Inom A 10.5 12.5 16.5 16.5 16.5 27 30 30 41 41 57 60 72 80 88 103 120 135 180 195 215 240 300 345 375 425 480 550 680 720 800 900 1000 1200 1480 1700 1950 Imax A 11.5 13.5 17.5 21 25 30 32 36 48 56 63 72 80 96 112 118 144 155 200 215 270 290 340 420 460 450 600 680 850 880 960 1100 1300 1440 1780 2040 2340 Ipeak 14 16 19 25 30 36 37 43 58 67 76 86 88 115 134 142 173 186 240 258 324 324 408 504 552 672 720 792 1020 1056 1152 1320 1560 1728 2136 2448 3024 Inom = Inverter nominal continuous current rating Imax = Inverter maximum current for 120 sec every 20 min up to S30 and 60 sec every 10 min all other sizes 1 peak = Inverter maximum current for 30 sec up to 175 % overload up to 200 % overload Catalogue Number Construction S Strong kW A 2.2 4.9 3 6.4 4 8.4 4.5 9 5.5 11.2 7.5 15 7.5 15 9.2 18 11 21 15 29 18.5 35 22 41 22 41 25 46 30 55 32 59 37 67 45 80 55 98 65 114 75 133 90 159 110 191 132 228 150 260 185 321 200 341 220 375 280 480 280 480 315 528 355 589 400 680 450 765 560 939 710 1200 800 1334 B Brake chopper X = None B = Integral A2 2 K Keypad EMC Filter X = None I = None K = Integral 3) A1 = First env. category C2 A2 = Second env. 3) category C3 B = First env. category C1 IP Rating 0 = IP 00 2 = IP 20 3 = IP 24-31 4 = IP 42 5 = IP 54 C = Air Cond. 2 3 - 32 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives SINUS PENTA - 380-415 V IP 20 / IP 00 NEW Frame S41 & S51: no more pre-charge bypass contactor and resistor offers you improved reliability compared to traditional pre-charge systems. Check availability with NHP. Ordering details Size S05 S20 Dimensions (mm) W D H 170 340 175 IP Rating IP 20 S12 215 401 225 IP 20 S15 225 466 331 IP 20 S20 279 610 332 IP 20 S30 302 748 421 IP 20 S41 500 882 409 IP 00 S51 578 882 409 IP 00 S60 890 1310 530 IP 00 S65 980 1400 560 IP 00 S75 1980 1400 560 IP 00 S05 Weight 7 7 7 7 7 10.5 10.5 10.5 11.5 11.5 12.5 12.5 22.5 22.5 36 36 36 36 51 51 51 51 117 117 121 121 141 141 141 260 260 440 440 440 550 550 550 Losses at Inom (W) 215 240 315 315 315 430 490 490 520 520 680 710 820 950 1050 1250 1350 1500 2150 2300 2450 2700 2550 3200 3450 3950 4400 4900 6300 7400 8400 9750 10750 12900 15400 17000 18600 Cat No. Price $ SP 0005 4TBA2K2 SP 0007 4TBA2K2 SP 0009 4TBA2K2 SP 0011 4TBA2K2 SP 0014 4TBA2K2 SP 0016 4TBA2K2 SP 0017 4TBA2K2 SP 0020 4TBA2K2 SP 0025 4TBA2K2 SP 0030 4TBA2K2 SP 0034 4TBA2K2 SP 0036 4TBA2K2 SP 0040 4TBA2K2 SP 0049 4TBA2K2 SP 0060 4TBA2K2 SP 0067 4TBA2K2 SP 0074 4TBA2K2 SP 0086 4TBA2K2 SP 0113 4TBA2K2 SP 0129 4TBA2K2 SP 0150 4TBA2K2 SP 0162 4TBA2K2 SP 0180 4TXA2K0 SP 0202 4TXA2K0 SP 0217 4TXA2K0 SP 0260 4TXA2K0 SP 0313 4TXA2K0 SP 0367 4TXA2K0 SP 0402 4TXA2K0 SP 0457 4TXA2K0 SP 0524 4TXA2K0 SP 0598 4TXA2K0 SP 0748 4TXA2K0 SP 0831 4TXA2K0 SP 0964 4TXA2K0 SP 1130 4TXA2K0 SP 1296 4TXA2K0 3 Price Schedule ‘M5’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 33 Variable speed drives Ordering details Size 3 S30 S05 Dimensions (mm) H W D IP Rating S05 214 577 227 IP 54 S12 250 622 268 IP 54 S15 288 715 366 IP 54 S20 339 842 366 IP 54 S30 359 1008 460 IP 54 Weight Losses at Inom (W) 15.7 15.7 15.7 15.7 15.7 22.3 22.3 22.3 23.3 23.3 24.3 24.3 40 40 54.2 54.2 57 57 76 76 76 76 215 240 315 315 315 350 380 420 525 525 680 710 820 950 1050 1250 1350 1500 2150 2300 2450 2700 Cat No. Price $ SP 0005 4TBA2K5 SP 0007 4TBA2K5 SP 0009 4TBA2K5 SP 0011 4TBA2K5 SP 0014 4TBA2K5 SP 0016 4TBA2K5 SP 0017 4TBA2K5 SP 0020 4TBA2K5 SP 0025 4TBA2K5 SP 0030 4TBA2K5 SP 0034 4TBA2K5 SP 0036 4TBA2K5 SP 0040 4TBA2K5 SP 0049 4TBA2K5 SP 0060 4TBA2K5 SP 0067 4TBA2K5 SP 0074 4TBA2K5 SP 0086 4TBA2K5 SP 0113 4TBA2K5 SP 0129 4TBA2K5 SP 0150 4TBA2K5 SP 0162 4TBA2K5 Price Schedule ‘M5’ 3 - 34 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives Input and output choke Input and output choke - 380-415 V Input choke: When installing a VSD of size S40 (230 kW) or less, a choke is recommended in the following situations: Q Q to reduce the impact of mains instability to protect against the effects of switching devices on the mains Q Q to reduce harmonics to improve wave shape For sizes S50 and above, it is recommended to always use a line reactor (choke) unless a dedicated transformer is used. DC chokes are available on request. Output choke: When installing a VSD of size S40 (230 kW) or less, an output choke is recommended in the following situations: Q Q Long motor output cables Reduce dV/dt to the motor Q Q Reduce reflected waves When multiple motors are connected to one VSD 3 For sizes S50 and above, it is recommended to always use an output reactor (choke). Ordering details 380-415 V Chokes IP 20/ IP 00 To suit size Suitable for SP...4T... input/output Input & Output 0005 0007-0014 Input & Output 0016-0020 Input & Output 0025-0030 Input & Output 0034-0038 Input & Output 0040-0060 Input & Output 0067-0086 Input & Output 0113-0162 Input & Output 0179-0202 Input & Output 0216-0260 Input & Output 0312-0399 Input & Output 0402-0598 Input & Output 0748-0831 Input & Output 0964-1130 Input 0964-1130 Output Input 1296 Output 1296 Rating Dimensions (mm) IP Weight Losses at (A) (mH) L H D Rating (kg) Inom (W) Cat. No. 29 11 120 125 75 IP 20 2.9 2 IMO126004 48 17 1.27 120 135 90 IP 20 3 IM0126044 70 32 150 175 105 IP 20 5 0.7 IM0126084 96 43 150 175 125 IP 20 6 0.7 IM0126124 150 68 180 160 150 IP 20 9 0.3 IM0126144 183 92 0.24 180 160 155 IP 00 10 IM0126164 142 0.16 240 210 170 IP 00 24.5 272 IM0126204 252 0.09 240 210 220 IP 00 24.5 342 IM0126244 407 362 0.061 300 260 220 IP 00 37 IM0126284 500 410 0.054 300 290 230 IP 00 53 IM0126324 500 662 0.033 300 290 230 IP 00 53 IM0126364 752 945 0.023 300 320 260 IP 00 67 IM0126404 1070 1260 0.018 300 320 260 IP 00 85 IM0126444 2 x 945 0.023 300 320 260 IP 00 2 x 67 2 x 752 2 X IM0126404 6 x 950 0.024 385 430 260 IP 00 2 x 100 6 x 940 6 X IMO141782 2 x 1260 0.018 300 320 260 IP 00 2 x 82 2 x 1070 2 X IM0126444 6 x 1250 0.018 385 430 260 IP 00 2 x 100 6 x 940 6 X IMO141782 Price $ IP 54 Choke A separate choke is available in IP 54, specifically designed to integrate into the IP 54 VSD solution. This choke fits under the drive to allow for connections. The choke can be used on either the input or output side of the drive. Ordering details 380-415 V Chokes IP 54 To suit size SP...4T... 0005 0007-0014 0016-0020 0025-0030 0034-0036 0038-0060 0067-0086 0113-0162 Suitable for input/output Input & Output Input & Output Input & Output Input & Output Input & Output Input & Output Input & Output Input & Output Dimensions (mm) IP Weight Losses at Rating H D Rating (kg) Inom (W) (A) (mH) L 29 214 225 214 IP 54 6.5 11 2.0 48 17 1.27 214 225 214 IP 54 7.0 70 214 225 214 IP 54 9.5 32 0.7 96 214 225 214 IP 54 10 43 0.7 150 280 270 244 IP 54 14 68 0.3 183 92 0.24 280 270 244 IP 54 15 342 142 0.16 310 360 318 IP 54 26 342 252 0.09 310 360 318 IP 54 33 Motor wiring with unscreened cables 2-4-6 pole motors Legend: Output chokes are required. Output chokes are optional Price Schedule ‘M5’ Price $ Cat. No. ZZ0112010 ZZ0112020 ZZ0112030 ZZ0112040 ZZ0112045 ZZ0112050 ZZ0112060 ZZ0112070 Motor wiring with screened cables 2-4-6 pole motors S05 - S12 Up to S12 S15 - S30 Up to S30 S40 Up to S40 from S40 S50 - S75 30 60 90 120 150 >150 m For further information please contact Sales 1300 NHP NHP or visit nhp.com.au 20 40 80 > 80 GST not included m 3 - 35 Variable speed drives Semiconductor fuses and EMC filters Semiconductor fuses Semiconductor fuses are recommended to protect the rectifier in the event of a short circuit. Standard fuses and circuit breakers alone are generally not adequate due to slower switch-off times. 3 To suit size SP---4T... Rating Dimensions (mm) For three fuses incl. base L H D 0005-0007 0009-0011 0014-0020 0025-0030 0034-0049 0060-0067 0074 0086 0113-0129 0150 0180 0162-0200 0202 0216-0217 0260-0313 0250-0367 0312-0399 0402 0457 0524 0598-0748 0831 0964 1130 1269 16 A 25 A 40 A 63 A 100 A 125 A 160 A 200 A 250 A 315 A 350 A 400 A 500 A 550 A 630 A 700 A 800 A 900 A 1000 A 1250 A 1400 A 2 x 800 A 2 x 1000 A 2 x 1250 A 2 x 1400 A 146 146 146 146 146 146 146 146 146 146 146 146 205 205 205 205 205 205 205 205 205 410 410 410 410 Accessories 120 120 120 120 120 120 120 120 120 120 120 120 120 258 258 258 258 258 258 258 258 258 258 258 258 68 68 68 68 68 68 68 68 68 68 68 68 68 104 104 104 104 104 104 104 115 115 104 104 115 Cat. No 1) Price $ 20 412 04 16 20 412 04 25 20 412 20 40 20 412 20 63 20 412 20 100 20 412 20 125 20 412 20 160 20 412 20 200 20 412 20 250 20 412 20 315 20 412 20 350 20 412 20 400 20 622 32 500 20 622 32 550 20 622 32 630 20 622 32 700 20 622 32 800 20 622 32 900 20 622 32 1000 20 622 32 1250 20 632 32 1400 20 632 32 800 2) 20 632 32 1000 2) 20 632 32 1250 2) 20 632 32 1400 2) Description To suit size SP ---4T BA2K2 Cat. No. Fuse base (one per fuse, three required per drive) 0005-0200 21 189 01 Fuse base (one per fuse, three or six required per drive) 0202-+ 21 313 02 Auxiliary switch 0005-0200 28 002 02 Auxiliary switch 0202-+ 28 001 04 Price $ EMC Filter for first environment When used in conjunction with the internal A2 (second environment) EMC filter, this ferrite allows the VSD to be suitable for use in the First Environment (class B) for residential and commercial use. The ferrite is installed between the output of the VSD and the motor by passing the three phases through the centre of the ferrite. Details upon request. Price Schedule ‘M5’ 3 - 36 Notes: 1) One fuse required per phase. 2 ) Two fuses required per phase. For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives Brake resistor selection by duty cycle Power Supply 380-500 V AC 5) Size S05 S12 S15 S20 S30 S40 S41 S50 S51 S60 Min. Braking Unit Resistance 1 Rating Model SP 0005 4TBA2K2 SP 0007 4TBA2K2 SP 0009 4TBA2K2 SP 0011 4TBA2K2 SP 0014 4TBA2K2 SP 0016 4TBA2K2 SP 0017 4TBA2K2 SP 0020 4TBA2K2 SP 0025 4TBA2K2 SP 0030 4TBA2K2 SP 0034 4TBA2K2 SP 0036 4TBA2K2 SP 0040 4TBA2K2 SP 0049 4TBA2K2 SP 0060 4TBA2K2 SP 0067 4TBA2K2 SP 0074 4TBA2K2 SP 0086 4TBA2K2 SP 0113 4TBA2K2 SP 0129 4TBA2K2 SP 0150 4TBA2K2 SP 0162 4TBA2K2 SP 0179 4TXA2K2 SP 0200 4TXA2K2 SP 0216 4TXA2K2 SP 0250 4TXA2K2 SP 0180 4TXA2K2 SP 0202 4TXA2K2 SP 0217 4TXA2K2 SP 0260 4TXA2K2 SP 0312 4TXA2K0 SP 0366 4TXA2K0 SP 0399 4TXA2K0 SP 0313 4TXA2K2 SP 0367 4TXA2K2 SP 0402 4TXA2K2 SP 0457 4TXA2K0 SP 0524 4TXA2K0 Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in Built-in 2 x BU200 2 x BU200 3 x BU200 3 x BU200 BU700 2-4T BU700 2-4T BU700 2-4T BU700 2-4T 4 x BU200 4 x BU200 4 x BU200 BU700 2-4T BU700 2-4T BU700 2-4T 5 x BU200 5 x BU200 50 50 50 50 50 50 50 50 20 20 20 15 15 10 10 10 8.5 8.5 6 6 5 5 10 10 10 10 1.1 1.1 1.1 1.1 10 10 10 1.1 1.1 1.1 10 10 Duty Cycle 20 % 4) Qty. Cat. No. 501 - 1100 W 501 - 1100 W 501 - 1100 W 501 - 1500 W 501 - 1500 W 501 - 2200 W 501 - 2200 W 501 - 4000 W 251 - 4000 W 251 - 4000 W 201 - 4000 W 201 - 4000 W 151 - 8000 W 101 - 12000 W 101 - 12000 W 101 - 12000 W 101 - 16000 W 101 - 16000 W 2 x 3.31 - 8000 W 1) 2 x 3.31 - 8000 W 1) 2 x 101 - 12000 W 2) 2 x 101 - 12000 W 2) 2 x 6.61 - 12000 W 3) 2 x 6.61 - 12000 W 3) 3 x 6.61 - 12000 W 3) 3 x 6.61 - 12000 W 3) 1 x 3.61- 32000 W 1 x 3.01- 48000 W 1 x 2.81- 48000 W 1 x 2.41- 48000 W 4 x 6.61 - 12000 W 3) 4 x 6.61 - 12000 W 3) 4 x 6.61 - 12000 W 3) 1 x 1.81- 64000 W 1 x 1.81- 64000 W 2 x 2.81- 48000 W 5 x 101 - 12000 W 3) 5 x 101 - 12000 W 3) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 3 3 1 1 1 1 4 4 4 1 1 2 5 5 RE3083500 RE3083500 RE3083500 RE3093500 RE3093500 RE3113500 RE3113500 RE3483500 RE3483250 RE3483250 RE3483200 RE3483200 RE3783150 RE4023100 RE4023100 RE4023100 RE4163100 RE4163100 RE3762330 RE3762330 RE4023100 RE4023100 RE4022660 RE4022660 RE4022660 RE4022660 RE4362360 RE4462300 RE4462280 RE4462240 RE4022660 RE4022660 RE4022660 RE4562180 RE4562180 RE4462280 RE4023100 RE4023100 Duty Cycle 50 % 4) Qty. Rating Cat. No. 1 501- 4000 W 1 501- 4000 W 1 501- 4000 W 1 501- 4000 W 1 501- 4000 W 1 501- 8000 W 1 501- 8000 W 1 501- 8000 W 1 201- 12000 W 1 201- 12000 W 1 201- 16000 W 1 201- 16000 W 1 151- 24000 W 1 151- 24000 W 1 101- 24000 W 1 101- 24000 W 1 2x151- 24000 W 1 2x151- 24000 W 1 61- 64000 W 1 61- 64000 W 1 51- 64000 W 1 51- 64000 W 3 x 101- 24000 W 3) 3 3 x 101- 24000 W 3) 3 3 x 101- 24000 W 3) 3 4 x 101- 24000 W 3) 4 1 1 x 6.61- 48000 W 1 1 x 6.01- 64000 W 1 1 x 5.01- 64000 W 1 1 x 5.01- 64000 W 4 x 101- 24000 W 3) 4 6 x 101- 24000 W 3) 6 6 x 101- 24000 W 3) 6 1 1 x 1.61- 48000 W 1 1 x 1.61- 48000 W 1 1 x 1.41- 64000 W 8 x 101- 24000 W 3) 8 10 x 101- 24000 W 3) 10 RE3503500 RE3503500 RE3503500 RE3503500 RE3503500 RE3783500 RE3783500 RE3783500 RE4053200 RE4053200 RE4163200 RE4163200 RE4293150 RE4293150 RE4293100 RE4293100 RE4293150 RE4293150 RE4562600 RE4562600 RE4562500 RE4562500 RE4293100 RE4293100 RE4293100 RE4293100 RE4462660 RE4562600 RE4552500 RE4552500 RE4293100 RE4293100 RE4293100 RE4462160 RE4462160 RE4562140 RE4293100 RE4293100 3 * Power supply 660 - 690 V AC Notes: ) Series connected resistors. ) Parallel connected resistors. 3 ) Refer SINUS PENTA Installation Manual for correct wiring of resistors and braking unit available at www.nhp.com.au/santerno. 4 ) 10 % duty cycle brake resistors also available. Contact NHP for further details. 5 ) 200-240 V AC (2T) resistors for all duty cycles (10 %, 20 %, 50 %) also available. Contact NHP for further details. Contact NHP for 690 V drive brake resistors. 1 2 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 37 Variable speed drives Brake resistors Dynamic braking allows a standard VSD to fully control the operation of the motor even when the motor acts as a generator. This can be the case when fast stopping times are required or the load has a high inertia. The use of a brake resistor allows the energy produced to be consumed, to avoid an alarm condition. Drives up to frame S30 (132 kW) come standard with an integral brake module. In order to utilise this braking function, an external resistor is required. For larger sizes an external brake unit (BU200) is required. 3 The resistors in the table on page 3 - 34 are rated for full braking but need to be selected based on the required duty cycle of operation. There are three selections possible. These are 10 %, 20 % and 50 % to cover the wide range of applications and requirements. Ordering details IP Rating Cat. No. 30 IP 55 RE3083500 120 40 IP 54 RE3093500 380 196 67 IP 54 RE3113500 15 - 4000 W 620 100 250 IP 20 RE3483150 20 - 4000 W 620 100 250 IP 20 RE3483200 25 - 4000 W 620 100 250 IP 20 RE3483250 50 - 4000 W 620 100 250 IP 20 RE3483500 50 - 4000 W 650 320 375 IP 23 RE3503500 3.3 - 8000 W 620 160 250 IP 20 RE3762330 10 - 8000 W 620 160 250 IP 20 RE3763100 50 - 8000 W 650 380 375 IP 23 RE3783500 6.6 - 12000 W 620 200 250 IP 20 RE4022660 10 - 12000 W 620 200 250 IP 20 RE4023100 20 - 12000 W 650 460 375 IP 23 RE4053200 15 - 16000 W 650 550 375 IP 23 RE4163150 10 - 24000 W 650 750 375 IP 23 RE4293100 0.8 - 64000 W 650 990 730 IP 23 RE4561800 1.2 - 48000 W 650 750 730 IP 23 RE4462120 1.6 - 48000 W 650 750 730 IP 23 RE4462160 6 - 48000 W 650 750 730 IP 23 RE4462600 0.8 - 64000 W 650 990 730 IP 23 RE4561800 1.2 - 64000 W 650 990 730 IP 23 RE4562120 1.6 - 64000 W 650 990 730 IP 23 RE4562160 2.4 - 64000 W 650 990 730 IP 23 RE4562240 5 - 64000 W 650 990 730 IP 23 RE4562500 Rating 1 W L Dimensions (mm) H D 50 - 1100 W 320 95 50 - 1500 W 320 50 - 2200 W Price $ Accessories Description To suit Cat. No. Adjustable thermal probe IP 23 Resistors WW0030460 BU200 380-500 V AC S40-S60 ZZ0063010 BU1440 380-500 V AC S65+ ZZ0063040 BU720 660-690 V AC S65 ZZ0063050 BU1440 660-690 V AC S65-S80 ZZ0063072 BU700 380-500 V AC S41+S51 ZZ0063020 Price $ Price Schedule ‘M5’ 3 - 38 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included THINK SALES SERVICE AND SUPPORT. THINK NHP. NHP has the largest product management, technical and engineering support and sales team in the Australasian electrical industry available 24 hours a day, 7 days a week, 365 days a year. Service Team Our dedicated Service Team are on call, easy to access, and are importantly experts in their own right, able to understand the challenges which need to be worked through to compete and be successful in the global market. Take the guesswork out of your project. Think Sales Service and Support. Think NHP. 1300 NHP NHP nhp.com.au 0800 NHP NHP nhp-nz.com Rating and selection chart 380-415 V 50 Hz S05 S12 Cat. No. 0007 0009 0011 0014 0016 0017 0020 0025 0030 0034 0036 SP_____4T BA2K2 0005 Light duty rating (120 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty Power (kW) 4.5 5.5 7.5 7.5 7.5 11 15 15 22 22 30 30 Current (A) 9 11.2 14.5 14.8 14.8 21 29 29 41 41 55 55 Standard duty rating (140 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty Power (kW) 4 4.5 5.5 7.5 7.5 9 11 15 18.5 22 25 30 Current (A) 8.4 9 11.2 14.8 14.8 18 21 29 35 41 46 55 Heavy duty rating (175 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty 3 Power (kW) 3 4 4.5 5.5 7.5 9 9 11 15 18.5 22 25 Current (A) 6.4 8.4 9 11.2 14.8 18 18 21 29 35 41 46 Strong duty rating (200 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty Power (kW) 2.2 3 4 4.5 5.5 7.5 7.5 9.2 11 15 18.5 22 Current (A) 4.9 6.4 8.4 9 11.2 15 15 18 21 29 35 41 Recommended circuit breaker Rating Cat. No. 16 A 25 A 32 A 40 A 63 A 100 A DTCB6316D DTCB6325D DTCB6332D DTCB6340D DTCB6363D S125GJ/100 Isolator switch Rating Cat. No. 20 A 25 A 32 A 40 A 63 A 100 A SLB20P3P SLB25P3P SLB32P3P SLB40P3P SLB63P3P SLB100P3P Semi-conductor fuses Rating Cat. No. 16 A 25 A 40 A 40 A 63 A 100 A 204120416 204120425 204122040 204122040 204122063 2041220100 Recommended line contactor (Refer to Part A, section 1 for more information) Rating Cat. No. 32 A AC 1 65 A AC 1 100 A AC 1 CA 7-9 CA 7-30 CA 7-60 Input/output choke Rating Cat. No. 11 A, 2.0 mH 17 A, 1.27 mH 32 A, 0.7 mH 43 A, 0.51 mH 68 A, 0.3 mH IMO126004 IMO126044 IMO126084 IMO126124 IMO126144 Output EMC ferrite ring (for compliance to the first environment in addition to the built-in A2 filter) 32 A Rating AC1810302 Cat. No. 32 A 64 A AC1810302 AC1810402 Dynamic brake resistor - 20 % duty cycle Rating Cat. No. 50 1, 1100 W 50 1, 1500 W 50 1, 2200 W 50 1, 4000 W 25 1, 4000 W 15 1, 4000 W RE3083500 RE3093500 RE3113500 RE3483500 RE3483250 RE3483150 Dynamic brake resistor - 50 % duty cycle Rating Cat. No. 3 - 40 50 1, 4000 W 50 1, 8000 W 20 1, 12000 W 20 1,16000 W RE3503500 RE3783500 RE4053200 RE4163200 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included S15 S20 S30 0040 0049 0060 0067 0074 0086 0113 0129 0150 0162 37 45 50 55 65 75 100 110 120 132 67 80 87 98 114 133 180 191 212 228 30 37 45 55 65 75 90 100 110 132 55 67 80 98 114 133 159 180 191 228 25 30 37 45 50 55 75 80 90 110 46 55 67 80 87 98 133 144 159 191 22 25 30 32 37 45 55 65 75 90 41 46 55 59 67 80 98 114 133 159 100 A 125 A 160 A 250 A 400 A S125GJ/100 S125GJ/125 S160GJ/160 S250GJ/250 S400NJ/400 100 A 125 A 125 A 160 A 200 A 250 A 315 A 400 A SLB100P3P SLB1253P SLB1253P SLB1603P SLB2003P SLB2503P SLB3153P SLB4003P 100 A 125 A 160 A 200 A 2041220100 2041220125 2041220160 250 A 2041220200 2041220250 315 A 400 A 2041220315 2041220400 100 A AC1 160 A AC1 250 A AC1 350 A AC1 CA 7-60 CA 6-95 CA 6-140 CA 6-210 92 A, 0.24 mH 92 A, 0.24 mH 142 A, 0.16 mH 252 A, 0.09 mH IM0126164 IM0126164 IM0126204 IM0126244 155 A 155 A 180 A 375 A AC1810603 AC1810603 AC1810604 AC1811004 15 1, 8000 W 10 1, 12000 W 10 1, 12000 W RE5783150 RE4023100 RE4023100 10 1, 16000 W 2 x 3.3 1, 8000 W 2 x 10 1, 12000 W RE4163100 2 x RE3762330 2 x RE4023100 15 1, 24000 W 10 1, 24000 W 2 x 15 124000 W 6 1, 64000 W 5 1, 64000 W RE4293150 RE4293100 RE4293150 RE4562600 RE4562500 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 3 - 41 Rating and selection chart 380-415 V 50 Hz S41 S51 Cat. No. 0180 0202 0217 0260 0313 0367 0402 SP_____4T XA2K2 Light duty rating (120 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty Power (kW) 160 200 220 250 280 315 400 Current (A) 273 341 375 425 480 528 680 Standard duty rating (140 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty Power (kW) 150 160 220 250 280 315 400 Current (A) 264 273 375 425 480 528 680 Heavy duty rating (175 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty 3 Power (kW) 132 160 185 220 250 280 355 Current (A) 228 273 321 375 421 480 589 Strong duty rating (200 % overload for 120 seconds every 20 minutes) - see application table page 3 - 28 for recommended duty Power (kW) 110 132 150 185 200 220 280 Current (A) 191 228 260 321 341 375 480 Recommended circuit breaker 400 A 630 A 630 A 800 A S400NJ/400 S630CE/630 S630CE/630 XS800NJ/800 Rating Cat. No. Isolator switch Rating Cat. No. 400 A 500 A 800 A 800 A SLB4003P SLB5003P SLB8003P SLB8003P Semi-conductor fuses Rating Cat. No. 350 A 500 A 550 A 630 A 700 A 800 A 1000 A 2041220350 2062232500 2062232550 2062232630 2062232700 2062232800 20622321000 Recommended line contactor Rating 450 A AC1 500 A AC1 780 A AC1 Cat. No. CA 6-300 CA 6-420 CA 5-550 Input / output choke Rating Cat. No. 362 A, 0.061 mH 410 A, 0.054 mH 662 A, 0.033 mH 945 A, 0.025 mH IM0126284 IM0126324 IM0126364 IM0126404 Output EMC ferrite ring (for compliance to the first environment in addition to the built-in A2 filter) 375 A 630 A AC1811004 AC1811202 Rating Cat. No. Dynamic brake resistor - 20 % duty cycle 1 x 3.0 1, 1 x 3.6 1, Rating 32000 W 48000 W Cat. No. RE4362360 RE4462300 Dynamic brake resistor - 50 % duty cycle 1 x 6.6 1, 1 x 6.0 1, Rating 48000 W 64000 W Cat. No. RE4462660 RE4562600 1 x 2.8 1, 48000 W 1 x 2.4 1, 48000 W 1 x 1.8 1, 64000 W 2 x 2.8 1, 48000 W RE4462280 RE4462240 RE4562180 RE4462280 1 x 5.0 1, 64000 W 1 x 1.6 1, 48000 W 1 x 1.4 1, 64000 W RE4552500 RE4462160 RE4562140 Notes: 1) A brake unit BU200 is required for each resistor used. 2) Standard ACB + Basic OCR (AGR-11). 3 - 42 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included S65 S60 S75 0457 0524 0598 0748 0831 0964 1130 1296 400 450 500 560 710 900 1000 1170 680 765 841 939 1200 1480 1646 1950 400 450 500 560 630 800 900 1100 680 765 841 939 1080 1334 1480 1874 315 355 400 500 560 710 800 900 528 589 680 841 939 1200 1334 1480 280 315 355 400 450 560 710 800 480 528 589 680 765 939 1200 1334 800 A 1000 A 1250 A XS800NJ/800 XS1250SE/1000 XS1250SE/1250 AR216S2) AR220S2) AR325S2) AR325S2) 1000 A 1250 A 1600 A 2000 A 2500 A SLB10003P SLB12503P SLB16003P SLB20003P SLB25003P 2 x 800 A 2 x 1000 A 1000 A 1250 A 1400 A 206223-21000 206223-21250 2063231400 1000 A AC1 1200 A AC1 CA 5-700 CA 5-700 CA 5-1000 945 A, 0.023 mH 945 A, 0.023 mH 1260 A, 0.018 mH IM0126404 IM0126404 IM0126444 5 x 10 1, 12000 W 2 x 2.4 1, 64000 W 5 X RE40231001) 2 X RE45622401) 10 x 10 1, 24000 W 8 X RE42931001) 10 X RE42931001) 2 x 1400 A 2 X 2063232800 2 X 20632321000 2 X 20632321250 2 X 20632321400 1000 A AC1 8 x 10 1, 24000 W 2 x 1250 A 3 4 x 1.2 1, 64000 W 4 X RE45621201) 2 x 1.6 1, 64000 W 2 x 945 A, 0.023 mH input, 6 x 950 A, 0.024 mH output 2 x IM0126404 input, 6 x IM0140674 output 2 x 945 A, 0.023 mH input, 6 x 1250 A, 0.018 mH output 2 x IM0126404 input, 6 x IM0140774 output 3 x 2.4 1, 64000 W 4 x 2.4 1, 48000 W 2 x 1260 A, 0.018 mH input, 6 x 1250 A, 0.018 mH output 2 x IM0126444 input, 6 x IM0140774 output 4 x 2.4 1, 64000 W 2 X RE4562160 3 X RE4562240 4 X RE4462240 4 X RE4562240 4 x 0.8 1, 64000 W 8 x 1.6 1, 48000 W 8 x 1.2 1, 48000 W 8 x 1.2 1, 64000 W 4 X RE45618001) 8 X RE44621601) 8 X RE44621201) 8 X RE45621201) Notes: 1) A brake unit BU200 is required for each resistor used. 2) Standard ACB + Basic OCR (AGR-11). For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 43 Variable speed drives SINUS PENTA 660-690 V range and selection Power supply 660-690 V AC S65 Light Size S14 3 S22 S32 S42 S52 2 x S42 2 x S52 3 x S52 S75 S80 Cat. No. SP 0003 6TBA2K2 SP 0004 6TBA2K2 SP 0006 6TBA2K2 SP 0012 6TBA2K2 SP 0018 6TBA2K2 SP 0019 6TBA2K2 SP 0021 6TBA2K2 SP 0022 6TBA2K2 SP 0024 6TBA2K2 SP 0032 6TBA2K2 SP 0042 6TBA2K2 SP 0051 6TBA2K2 SP 0062 6TXA2K2 SP 0069 6TXA2K2 SP 0076 6TXA2K2 SP 0088 6TXA2K2 SP 0131 6TXA2K2 SP 0164 6TXA2K2 SP 0181 6TXA2K0 SP 0201 6TXA2K0 SP 0218 6TXA2K0 SP 0259 6TXA2K0 SP 0290 6TXA2K0 SP 0314 6TXA2K0 SP 0368 6TXA2K0 SP 0401 6TXA2K0 SP 0459 6TXA2K0 SP 0526 6TXA2K0 SP 0600 6TXA2K0 SP 0750 6TXA2K0 SP 0828 6TXA2K0 SP 0960 6TXA2K0 SP 1128 6TXA2K0 SP 1130 6TXA2K0 SP 1296 6TXA2K0 Light up to 120 % overload Standard up to 140 % overload Standard Heavy Strong Inom Imax kW A kW A kW A kW A A A Ipeak 5.5 7.5 7.5 11 15 15 22 30 37 45 55 75 75 90 110 132 160 200 250 315 355 400 450 500 560 630 710 800 900 1000 1200 1400 1650 1750 2010 6.3 8.4 8.4 12.1 16.8 16.8 23 33 39 46 56 78 80 95 115 140 165 205 250 310 350 390 440 480 544 626 696 773 858 954 1150 1360 1550 1700 1950 4 5.5 7.5 7.5 11 11 18.5 22 30 37 45 55 75 90 110 132 160 200 250 315 315 400 450 450 500 630 710 710 800 1000 1100 1400 1400 1620 1850 4.8 6.3 8.4 8.4 12.1 12.1 21 23 33 39 46 56 80 95 115 140 165 205 250 310 310 390 440 450 480 626 696 696 773 954 1086 1360 1360 1569 1800 4 4 7.5 7.5 11 11 15 22 22 37 37 55 65 75 90 110 132 160 220 250 315 355 400 450 500 560 630 710 800 900 1000 1200 1400 1400 1610 4.8 4.8 8.4 8.4 12.1 12.1 16.8 23 23 39 47 56 67 80 95 115 140 165 205 250 310 341 390 440 480 544 626 696 773 858 954 1150 1360 1360 1560 3 4 5.5 7.5 9.2 9.2 11 18.5 22 30 30 45 55 55 75 90 110 132 185 220 220 315 315 355 375 450 560 630 630 710 800 1000 1000 1100 1380 3.7 4.8 6.3 8.4 10.2 10.2 12.1 21 23 33 33 46 60 60 80 100 115 140 190 220 205 310 310 341 360 440 544 626 626 696 773 954 954 1086 1337 7 9 11 13 17 21 25 33 40 52 60 80 85 100 125 150 190 230 290 330 360 400 450 500 560 640 720 800 900 1000 1150 1400 1600 1700 1950 8.5 11 13.5 16 21 25 30 40 48 63 72 96 110 130 165 200 250 300 380 420 465 560 600 650 720 850 1000 1050 1100 1300 1440 1800 2000 1700 2340 10 13 16 19 25 30 36 48 58 76 86 115 132 156 198 240 300 360 456 504 558 672 720 780 864 1020 1200 1260 1320 1560 1728 2160 2400 2448 2528 Heavy Strong up to 175 % overload up to 200 % overload Inom = Inverter nominal continuous current rating Imax = Inverter maximum current for 60 sec every 10 min Ipeak = Inverter maximum current for 5 sec Price Schedule ‘M5’ 3 - 44 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives SINUS PENTA 660-690 V range and selection Ordering details - SINUS PENTA - 660-690 V IP 00 IP Rating Weight (kg) Losses at Inom (W) 1) Cat No. IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 20 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 128 128 128 128 128 128 128 128 136 136 160 160 160 160 440 440 440 440 440 440 440 440 990 990 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1 ) 1300 1450 1700 1950 2300 2750 3450 3900 4550 4950 5950 6400 7000 7650 5000 6100 6900 8000 9150 9800 11250 12450 21900 24000 SP 0003 6TBA2K2 SP 0004 6TBA2K2 SP 0006 6TBA2K2 SP 0012 6TBA2K2 SP 0018 6TBA2K2 SP 0019 6TBA2K2 SP 0021 6TBA2K2 SP 0022 6TBA2K2 SP 0024 6TBA2K2 SP 0032 6TBA2K2 SP 0042 6TBA2K2 SP 0051 6TBA2K2 SP 0062 6TXA2K0 SP 0069 6TXA2K0 SP 0076 6TXA2K0 SP 0088 6TXA2K0 SP 0131 6TXA2K0 SP 0164 6TXA2K0 SP 0181 6TXA2K0 SP 0201 6TXA2K0 SP 0218 6TXA2K0 SP 0259 6TXA2K0 SP 0290 6TXA2K0 SP 0314 6TXA2K0 SP 0368 6TXA2K0 SP 0401 6TXA2K0 SP 0250 6TXA2K0 SP 0312 6TXA2K0 SP 0366 6TXA2K0 SP 0399 6TXA2K0 SP 0457 6TXA2K0 SP 0524 6TXA2K0 SP 0598 6TXA2K0 SP 0748 6TXA2K0 SP 1130 6TXA2K0 SP 1296 6TXA2K0 Losses at Inom (W) Cat No. Dimensions (mm) Size S14 W H ) ) 1 1 ) 1 ) 1 S22 1 S32 1 D 1 ) ) 1 ) ) 1 ) S42 500 968 409 S52 578 968 409 S65 980 1400 560 S80 2230 1400 560 1 1 Price $ 3 Options to suit SINUS PENTA 6T models Input Chokes - 660-690 V Rating Dimensions (mm) H P Applicable size SP---6TXA2K0 A mH L 0250 0312-0399 0457-0598 0748 0831 0964 1130 1296 410 662 945 1260 2 x 662 2 x 945 3 x 662 3 x 1050 0.093 0.058 0.040 0.030 0.058 0.040 0.058 0.040 300 360 360 420 360 360 360 360 290 310 390 410 310 390 310 390 220 250 270 290 250 270 250 270 IP Rating Weight (kg) IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 581 52 746 79 1193 88 1438 110 2 x 79 2 x 746 2 x 88 2 x 1193 3 x 79 3 x 746 3 x 88 3 x 1193 IP Rating Weight (kg) Losses at Inom (W) Cat No. IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 52 79 88 110 TBA TBA 581 746 1193 1438 6 x 400 6 x 500 IM0127324 IM0127364 IM0127404 IM0127444 6 x IM0141724 6 x IM0141784 Price $ IM0127324 IM0127364 IM0127404 IM0127444 2 x IM0127364 2 x IM0127404 3 x IM0127364 3 x IM0127404 Output Chokes - 660-690 V Rating Dimensions (mm) H P Applicable size SP---6TXA2K0 A mH L 0250 0312-0399 0457-0598 0748-0831 0963-1130 1296 410 662 945 1260 6 x 900 6 x 1050 0.093 0.058 0.040 0.030 0.058 0.040 300 360 360 420 TBA TBA Price Schedule ‘M5’ Notes: ) 1 290 310 390 410 TBA TBA 220 250 270 290 TBA TBA Price $ Refer to NHP for data and availability For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 45 Variable speed drives SINUS PENTA - Multi-pump application Application software SW Multi-pump operation On-site commissioning and application support Cat. No. Price $ ZZ4590010 NHPSERVICE The SINUS PENTA Variable Speed Drive when combined with special software becomes a high level integrated pump control system. This software can be added to any SINUS PENTA drive and is field loadable using the Remote Drive PC software package or can be supplied, pre-installed on request. The software provides a high level of control with flexible options for configuration, control and monitoring. The multi-pump system can be used to control a system of up to 5 pumps including the master. The drive can be used to control this system without any additional hardware. The drive utilises the internal PID loop and control functionality to control the operation of not only the master but the slave drives also. 3 FILLING AC MAINS Fixed speed operation EMPTYING FLOW SINUS PENTA MUP MASTER The fixed speed operation provides an economical Multipump solution where the master SINUS PENTA drive is used to control the process and the slaves are operated at fixed speed and bought on-line by the master when the capacity of the master is exceeded. When demand reduces, the master sheds the pumps off the system to maintain the process demand. A fixed speed system can be configured using a combination of Direct On-Line (DOL), Star-Delta or Soft Starters and connected using either standard I/O wiring or Modbus communication. PRESSURE M1 P1 Q SLAVE 1 M2 P2 M…n P…n SLAVE 2 SINUS PENTA MUP master controlling a fixed speed DOL and AuCom soft starter Variable speed operation FILLING AC MAINS EMPTYING Variable speed operation allows for the most efficient and energy saving option for a pump system. By using variable speed drives on all pumps and varying their speed, the pumps can all be run at the lowest level to ensure the lowest energy usage level. As a result the operation of a variable system provides the same energy savings of a single pump, multiplied across all of the pumps. The master will determine which drives are required in order to maintain the demand based on user defined minimum and maximum operation levels. A complete variable speed system has the added benefit of providing a faster response to changing load conditions and is able to maintain a more stable system. FLOW SINUS PENTA MUP MASTER PRESSURE M1 P1 Q SLAVE 1 M2 P2 M…n P…n SLAVE 2 SINUS PENTA MUP master with SINUS Nano and SINUS Micro variable speed slaves FILLING Multi-master control AC MAINS In order to provide ultimate redundancy, the Multi-pump application incorporates Multi-master control. Multi-master control allows two drives to act as master and therefore the loss of the master will not effect the system operation. With Multi-master if the master becomes unavailable for use, control transfers to the second Multi-master. This allows the system to continue to function in the same way as if a slave was lost. The Multi-master drives operate continuously to calculate the required output even if the particular drive is not acting as the master at that time. This way it is always ready to take over the process with no interruption to operation. A combination of fixed and variable speed slaves can be used in this configuration. Price Schedule ‘M5’ 3 - 46 EMPTYING FLOW MUP PRIMARY MASTER PRESSURE M1 P1 Q MUP SECONDARY MASTER M2 P2 M…n P…n SLAVE 1 SINUS PENTA MUP primary master with SINUS PENTA secondary master and SINUS Micro slave For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives SINUS PENTA - Regenerative application Application software Regenerative Operation On-site commissioning and application support Cat. No Price $ ZZ4590010 NHPSERVICE The entire SINUS PENTA range of drives can be offered using an Active Front End (commonly referred to as an AFE) for use as a regenerative power supply system. It is defined as an AFE as the inverter becomes an active front end power supply unit that absorbs or sends sinusoidal current in the mains with unity power factor which has been regenerated from the load. The AFE has a stabilised direct voltage (DC link) as an output that is used to power one or more SINUS PENTA inverters through a direct DC connection. The AFE and the motor inverter drive are identical SINUS PENTA units except for the regenerative application software installed on the AFE inverter unit. 3 Inductances are used between the AFE and the power mains in order to filter the pulse width modulated (PWM) voltage on the inverter output terminals and to make the current exchanged with the mains sinusoidal. It is also necessary to use a line contactor and a regenerative interface which are supplied complete with capacitive filters. The use of a SINUS PENTA inverter as a regenerative unit has four main benefits over a standalone unit: 1. Unity power factor 2. Almost 0 % THD 3. 100 % braking torque 4. Line regeneration back into the grid By the very nature of the AFE system using two inverters connected inversely to each other, the system is able to present to the mains power unity power factor which removes the need for additional power factor correction systems. In addition to this, requirements imposed by electricity distributors to minimise total harmonic distortion levels to levels generally <5 % are easily achieved using an AFE system without the need for additional harmonic filters hence saving significant savings in initial cost and cabinet space. 100 % braking torque is able to be absorbed by the AFE system making it perfectly suited for high inertia load applications such as: • Lifts • Conveyors • Fans • Centrifuges, etc. which require fast deceleration times without the need for additional braking resistors and braking units. When using braking resistors and braking units, this excess energy is dissipated in the form of heat which requires greater ventilation requirements and cabinet sizes. When using an AFE system, the excess energy is transferred through the AFE back into the mains grid connection which if properly monitored can save thousands of dollars in annual energy bills. Price Schedule ‘M5’ For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 47 Variable speed drives Adde 24 V d au cont rol s x u pply and comm more s car ds SINUS PENTA - Options Remote mounting kits Description Cat. No. Remote mounting kit for keypad to IP 55 with a 3 m cable Remote mounting kit for keypad to IP 55 with a 5 m cable ZZ0095699 ZZ0095700 Heatsink segregation kit for frame S05 Heatsink segregation kit for frame S12 ZZ0095210 ZZ0121920 Price $ I/O Expansion cards ES 847 I/O Expansion card (required for some special application software) 8 digital inputs, 6 digital outputs and 4 analogue inputs or PT100 This card mounts in the I/O slot within the drive. ES 870 I/O Expansion card 12 digital inputs and 6 relay outputs This card mounts in the I/O slot within the drive. ES 914 Isolated aux 24 V DC supply RS485 3 ZZ0101812 ZZ0101840 ZZ0101790 Communication option cards ES 822 Insulated card for RS 232 and/or RS 485 communication and is suggested for Modbus networks. ZZ0095850 This card mounts in the communications slot within the drive. These cards mount in the communications slot within the drive. Profibus® DP card (kit hardware and software) DeviceNet™ card (kit hardware and software) Interbus card (kit hardware and software) CANOpen card (kit hardware and software) ControlNet card (kit hardware and software) Ethernet+IT card (kit hardware and software) Lonworks card Metesys Nz card BacNet 485 card BacNet Ethernet card ES 851 Datalogger / energy monitor, WEB server, ethernet, modem ZZ4600040 ZZ4600050 ZZ4600060 ZZ4600070 ZZ4600080 ZZ4600100 ZZ4600085 ZZ0102406 ZZ0102402 ZZ0102404 ZZ0101820 Encoder card This card mounts in the encoder slot within the drive. ES 836 Encoder card with internal 5-24 V encoder supply ZZ0095834 3) PC software kits Kit for use with remote drive software includes cable and USB/RS 485 converter. Download remote drive from www.nhp.com.au/santerno SPUSB Harmonic Filters A range of harmonic filters to suit all SINUS PENTA drives are available which limits the THD to 5 %. Contact NHP for further information for correct selection. Refer NHP IP 54 customised control kits to suit SP --- 4T BA2K5 models 1) Potentiometer and start / stop pushbuttons Potentiometer and forward / off / reverse selector switch Emergency stop and local / off / remote selector switch Other combinations available to suit the specific application Notes: SP501- XX 2) SP502- XX 2) SP500- XX 2) ) Kit includes metal cover with buttons and wiring loom. ) Replace ‘xx’ with frame size number. 3 ) SINCOS and resolver/ encoder card with repeater available 1 2 Price Schedule ‘M5’ 3 - 48 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included Variable speed drives SINUS PENTA Specifications Power range: 2.2-1170 kW / 5 - 1950 A (4T) 75 -2010 kW / 278 - 1950 A (6T) Input voltage: AC Supply DC Supply Input frequency: 4T - 380-500 V AC, 3 phase, - 15 % + 10 % 6T - 525-690 V AC, 3 phase, - 15 % + 10 % 4T - 530-705 V DC, -15 % + 10 % 4T - 810-970 V DC, -15 % + 10 % 50-60 Hz, +/- 10 % 0-Vin + 2 % Output voltage: Control system: IFD - V/f control VTC - (open/closed loop) - Vector torque control FOC - Field orientated closed loop control RGN - Regenerative front end (option) MUP - Multipump application (option) 3 Overload current rating: In accordance with overload selected for 120 secs every 20 mins up to frame S30 and 60 secs every 10 mins for all other sizes. Starting torque: Max 240 % for a short time and up to 200 % for 120 secs (dependent on overload selected) Frequency/Speed resolution: 0.1 Hz IFD, 1 rpm VTC, 0.01 rpm FOC Speed accuracy: Open loop + 0.5 % of max. speed Closed loop < 0.01 % of max. speed Carrier frequency: Braking: 0.8 -16 kHz with silent mode, dependent on size and control type 30 % DC braking 20 % dynamic braking without brake resistor Up to 150 % with internal brake module and external resistor (up to frame S30) or external brake unit and resistor for all other sizes. Protection functions: Overcurrent, overvoltage, undervoltage, overload, inverter thermal protection, motor thermal protection, mains failure, communications error, auxiliary fault, encoder error. Frequency setting: Digital keypad, external potentiometer, 0 to 10 V, 4 to 20 mA, preset speeds, up/down control, serial interface. Digital keypad, digital inputs, serial interface 3 inputs, selectable between 0-10 V and 0 (4) - 20 mA (12 bit resolution) Input AIN2 can also be used for PTC thermistor monitoring Control setting: Analogue inputs: Digital inputs: 8 inputs - 3 fixed, 5 programmable (multiple assignment possible) Analogue outputs: 3 outputs, selectable between 0-10 V, -10-+10 V and 0 (4)-20 mA Digital outputs: 1 push-pull transistor output (20-48 V DC, 50 mA max.) 1 open collector transistor output (5-48 V DC, 50 mA max.) 2 relay outputs with changeover contacts (250 V AC, 30 V DC, 3A) 4 line alphanumeric display 11 status LEDs Dedicated keys for start, stop, fwd/rev, jog, reset, loc/rem, tx/rx IP 20 from size S05 to size S40 IP 00 from size S41 to size S80 IP 54 from size S05 to Size S30 Keypad: Enclosure protection: Environmental: Communication: Standard Optional 0 to +40 °C operation or to 50 °C with derating 5 to 95 % RH non-condensing Modbus / RS 485 Profibus®, DeviceNet™, Interbus, CANOpen, ControlNet, Ethernet, Lonworks, BacNet, NZ EMC: AS 61800-3, category C3, second environment or Category C2, first environment with optional ferrite. Safety: Safe torque off, SIL 3, to IEC standard. Approvals: For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included 3 - 49 Alphanumeric Index 2 CAT. NO. PAGE 170H1007 170H1007 170H1007 170H3003 170H3003 170H3003 170H3004 170M1314 170M1314 170M1314 170M1316 170M1317 170M1317 170M1318 170M1318 170M1318 170M1319 170M1319 170M1319 170M1321 170M1321 170M1321 170M1322 170M1322 170M2621 170M3022 170M3022 170M5011 170M5015 170M5017 170M6008 170M6009 170M6010 170M6011 170M6013 170M6015 170M6017 170M6018 170M6019 3-8 3 - 11 3 - 20 3-8 3 - 11 3 - 20 3 - 20 3-8 3 - 11 3 - 20 3 - 20 3-8 3 - 11 3-8 3 - 11 3 - 20 3-8 3 - 11 3 - 20 3-8 3 - 11 3 - 20 3-8 3 - 11 3 - 20 3-8 3 - 11 3 - 20 3 - 20 3 - 20 3 - 20 3 - 20 3 - 20 3 - 20 3 - 20 3 - 20 3 - 20 3 - 20 3 - 20 20 412 04 16 20 412 04 25 20 412 20 100 20 412 20 125 20 412 20 160 20 412 20 200 20 412 20 250 20 412 20 315 20 412 20 350 20 412 20 40 20 412 20 400 20 412 20 63 20 622 32 1000 20 622 32 1250 20 622 32 500 20 622 32 550 20 622 32 630 20 622 32 700 20 622 32 800 20 622 32 900 20 632 32 1000 20 632 32 1250 20 632 32 1400 20 632 32 800 21 189 01 21 313 02 28 001 04 28 002 02 289-506 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 3 - 36 1 - 12 40.51 24 VDC 1 - 12 55150 55.1.50 55151 55.1.51 55152 55.1.52 55164 55.1.64 55.2.16 55.2.17 2-9 2 - 15 2-9 2 - 15 2-9 2 - 15 2-9 2 - 15 2 - 15 2 - 15 1 2 4 5 CAT. NO. PAGE CAT. NO. PAGE 55.2.37 55.2.46 55.1.50SS 55.1.51SS 55.1.52SS 55153P 55.1.53P 55.1.53RLR 55.1.53RLR-PM 55.1.64SS 55.2.16GW 55.2.16PL 55.2.19NTW 55.2.46SS 55.4.00GWNBB 55.4.00LHGWNBB 55.4.00LHNBB 55.4.00NBB 55.4.00RHGWNBB 55.4.00RHNBB 55.4.01LHNBB 55.4.01NBB 55.4.01RHNBB 55.4.01STRANBB 554LVKIT 2 - 15 2 - 15 2 - 15 2 - 15 2 - 15 2-9 2 - 16 2 - 16 2 - 16 2 - 15 2 - 15 2 - 15 2 - 15 2 - 15 2 - 14 2 - 14 2 - 14 2 - 14 2 - 14 2 - 14 2 - 14 2 - 14 2 - 14 2 - 14 2 - 15 750-300 750-304 750-305 750-306 750-310 750-312 750-313 750-314 750-315 750-316 750-319 750-319/004-000 750-320 750-331 750-333 750-333/025-000 750-334 750-337 750-337/025-000 750-338 750-339 750-340 750-341 750-342 750-343 750-344 750-345 750-346 750-347 750-348 750-350 750-351 750-370 750-400 750-400/025-000 750-401 750-402 750-402/025-000 750-403 750-404 750-405 750-406 750-408 750-409 750-410 750-411 750-412 750-414 750-415 750-418 750-421 750-422 750-423 750-424 750-425 750-427 750-428 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 25 1 - 21 1 - 21 1 - 25 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 22 1 - 25 1 - 22 1 - 22 1 - 25 1 - 22 1 - 24 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 750-430 750-430/025-000 750-431 750-432 750-433 750-435 750-436 750-437 750-438 750-452 750-453 750-454 750-454/025-000 750-455 750-455/025-000 750-456 750-457 750-459 750-460 750-461 750-465 750-466 750-466/025-000 750-467 750-468 750-469/00000 750-469/000001 750-469/000002 750-469/000003 750-469/000006 750-469/000008 750-469/000012 750-469/003000 750-472 750-473 750-474 750-475 750-476 750-477 750-478 750-479 750-480 750-481 750-482 750-483 750-485 750-491 750-491/000-001 750-492 750-493 750-493/000-001 750-501 750-502 750-504 750-504/025-000 750-506 750-508 750-509 750-511 750-512 750-513 750-514 750-516 750-517 750-519 750-522 750-523 750-530 750-530/025-000 750-531 750-532 750-535 750-536 750-537 750-550 750-552 750-553 750-554 750-555 750-556 750-557 750-559 750-560 1 - 22 1 - 25 1 - 22 1 - 22 1 - 22 1 - 28 1 - 22 1 - 22 1 - 28 1 - 23 1 - 23 1 - 23 1 - 25 1 - 23 1 - 25 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 25 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 28 1 - 23 1 - 23 1 - 28 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 22 1 - 22 1 - 22 1 - 25 1 - 22 1 - 22 1 - 22 1 - 24 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 22 1 - 25 1 - 22 1 - 22 1 - 28 1 - 22 1 - 22 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 1 - 23 7 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included PAGE CAT. NO. PAGE 750-585 750-600 750-601 750-602 750-602/025-000 750-603 750-604 750-609 750-610 750-611 750-612 750-613 750-614 750-615 750-616 750-621 750-622 750-623 750-624 750-625 750-626 750-627 750-628 750-630 750-631/000-004 750-634 750-635 750-636 750-637 750-638 750-640 750-641 750-642 750-643 750-644 750-645 750-645 750-650/003000 750-651 750-653/003000 750-653/025-000 750-653/025-018 750-654 750-655 750-655 750-655KIT 750-660 750-665 750-666 750-670 750-671 750-804 750-806 750-812 750-812/025-000 750-814 750-815 750-815/025-000 750-816 750-819 750-830 750-833 750-833/025-000 750-833KIT 750-837 750-838 750-840 750-841 750-841/025-000 750-841KIT 750-842 750-842KIT 750-849 750-860 750-871 750-873 750-881 750-920 750-920 750-920 750-921 750-921 750-921 1 - 28 1 - 24 1 - 24 1 - 24 1 - 25 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 28 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 24 1 - 30 1 - 24 1 - 24 1 - 24 1 - 25 1 - 25 1 - 24 1 - 24 1 - 31 1 - 34 1 - 29 1 - 29 1 - 29 1 - 24 1 - 24 1 - 21 1 - 21 1 - 21 1 - 25 1 - 21 1 - 21 1 - 25 1 - 21 1 - 21 1 - 21 1 - 21 1 - 25 1 - 34 1 - 21 1 - 21 1 - 21 1 - 21 1 - 25 1 - 34 1 - 21 1 - 34 1 - 21 1 - 21 1 - 21 1 - 21 1 - 21 1 - 25 1 - 27 1 - 33 1 - 24 1 - 25 1 - 27 750-921 750-923 750-923 750-923 750-925 750-925 750-960 750-961 750-962 750-963 750-965 750-970 751-3001 751-3002 751-3501 751-3502 751-4001 751-4501 751-5201 751-5202 751-5701 751-5702 753-110 753-150 753-400 753-401 753-402 753-403 753-404 753-405 753-406 753-408 753-409 753-410 753-411 753-412 753-415 753-418 753-421 753-422 753-423 753-424 753-425 753-427 753-428 753-430 753-431 753-432 753-433 753-434 753-440 753-452 753-453 753-454 753-455 753-456 753-457 753-459 753-461 753-465 753-466 753-467 753-469 753-472 753-474 753-475 753-476 753-477 753-478 753-479 753-480 753-482 753-483 753-492 753-501 753-502 753-504 753-506 753-507 753-509 753-512 753-513 753-514 1 - 33 1 - 25 1 - 27 1 - 33 1 - 24 1 - 30 1 - 25 1 - 25 1 - 25 1 - 25 1 - 25 1 - 25 1 - 31 1 - 31 1 - 31 1 - 31 1 - 31 1 - 31 1 - 31 1 - 31 1 - 31 1 - 31 1 - 37 1 - 37 1 - 36 1 - 36 1 - 36 1 - 36 1 - 37 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au CAT. NO. 753-516 753-517 753-530 753-531 753-534 753-540 753-550 753-552 753-554 753-556 753-557 753-559 753-603 753-604 753-614 753-635 753-638 753-646 753-650 753-653 753-661 753-662 753-667 758-912 759-302 759-302 759-332 759-333 77.1.06 77.1.10 77.1.21 77.1.25 77.1.30 77.1.31 77.2.11 77.2.34 77.2.39 77.2.40 77.2.50 787-602 787-612 787-692 787-692 PAGE 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 36 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 37 1 - 29 1 - 29 1 - 29 1 - 24 1 - 31 1 - 33 1 - 33 1 - 33 2 - 19 2 - 19 2 - 19 2 - 19 2 - 19 2 - 19 2 - 19 2 - 19 2 - 19 2 - 19 2 - 19 1 - 25 1 - 25 1 - 25 1 - 31 810-900/000-001 810-901/000-001 810-902/000-001 857-400 857-411 857-412 857-420 857-421 857-423 857-451 857-452 857-800 857-801 857-810 857-811 1 - 25 1 - 25 1 - 25 1 - 27 1 - 27 1 - 27 1 - 27 1 - 27 1 - 27 1 - 27 1 - 27 1 - 27 1 - 27 1 - 27 1 - 27 955-04938-00 95AZB1 95AZB5 9950350300A 9950350300A 995-04803-00 995-04804-00 995-06348-00 995-08133-00 3 - 20 2-2 2-2 3-8 3 - 11 3 - 20 3 - 20 3 - 20 3 - 20 ACTWINCD ACTWINH ACTWINH ACTWINM1 ADAPT1605 ADROIT1500RC ADROIT1500SI ADROIT1500SI-A ADROIT150RC ADROIT150SI ADROIT150SI-A ADROIT25000RC ADROIT25000SI 1-9 1-9 1 - 13 1-9 1 - 47 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 GST not included Alphanumeric Index CAT. NO. 8 9 A 3 Alphanumeric Index 4 CAT. NO. PAGE CAT. NO. PAGE CAT. NO. PAGE ADROIT25000SI-A ADROIT2500RC ADROIT2500SI ADROIT2500SI-A ADROIT300RC ADROIT300SI ADROIT300SI-A ADROIT30RC ADROIT30SI ADROIT30SI-A ADROIT5000RC ADROIT5000SI ADROIT5000SI-A ADROIT750RC ADROIT750SI ADROIT750SI-A ADROIT75RC ADROIT75SI ADROIT75SI-A ADROITULRC ADROITULSI ADROITULSI-A AL-210-MRA AL-210-MRD AL2-14AC-KIT AL2-14DC-KIT AL-214-MRA AL-214-MRD AL2-24AC-KIT AL2-24DC-KIT AL-224-MRA AL-224-MRD AL2-2DA AL2-2PT-ADP AL2-2TC-ADP AL-232-CAB AL2-4EX AL2-4EX-A2 AL2-4EYR AL2-4EYT AL2-EEPROM-2 AL2-GSM-CAB AL-DVD ALPHAGSMMODEM ALPHANXGMODEM ANT1 AZM415202SA3D AZM415202SR3D AZM415 B1 AZM415 B2 AZM415 B3 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1 - 66 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-5 1-4 1-4 1-4 1-5 1-5 1-5 1-5 1-4 1-4 1-4 1-4 1-4 1 - 47 2-5 2-5 2-5 2-5 2-5 CSX-055-V4-C1 CSX-055-V4-C2 CSX-075-V4-C1 CSX-075-V4-C2 CSX-090-V4-C1 CSX-090-V4-C2 CSX-110-V4-C1 CSX-110-V4-C2 CSXI-007-V4-C1 CSXI-007-V4-C2 CSXI-015-V4-C1 CSXI-015-V4-C2 CSXI-018-V4-C1 CSXI-018-V4-C2 CSXI-022-V4-C1 CSXI-022-V4-C2 CSXI-030-V4-C1 CSXI-030-V4-C2 CSXI-037-V4-C1 CSXI-037-V4-C2 CSXI-045-V4-C1 CSXI-045-V4-C2 CSXI-055-V4-C1 CSXI-055-V4-C2 CSXI-075-V4-C1 CSXI-075-V4-C2 CSXI-090-V4-C1 CSXI-090-V4-C2 CSXI-110-V4-C1 CSXI-110-V4-C2 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 3 - 11 D32124000 D38920000024 D38920000115 D38920000230 D63696475024 D63696475230 DT01 DT02 DUPDATACC DUPSERVADD DUPSERVSW 1 - 47 1 - 46 1 - 46 1 - 46 1 - 47 1 - 47 1 - 47 1 - 47 1 - 47 1 - 47 1 - 47 BZ1602D BZ1602U BZ1602V BZ1611D BZ1611U BZ1611V BZ16B1 2-7 2-7 2-7 2-7 2-7 2-7 2-7 CBL-1509 CBL-1509 CBL-1509 CBL90H CMR7110VA CMR712VDC CMR7230VA CMR724VA CMR724VDC CSX-007-V4-C1 CSX-007-V4-C2 CSX-015-V4-C1 CSX-015-V4-C2 CSX-018-V4-C1 CSX-018-V4-C2 CSX-022-V4-C1 CSX-022-V4-C2 CSX-030-V4-C1 CSX-030-V4-C2 CSX-037-V4-C1 CSX-037-V4-C2 CSX-045-V4-C1 CSX-045-V4-C2 1-9 1 - 13 1 - 54 1 - 54 3-6 3-6 3-6 3-6 3-6 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 3-8 EEX GF1O1S EEX GFS1O1S EEXST-14-10/1S 5M EEXZS-71 10/1S WVD EEXZS-73 10/1S WVD EH-A14AS EH-A14DR EH-A14EDR EH-A20DR EH-A23DRP EH-A28AS EH-A28DR EH-A28DRP EH-A28EDR EH-A40DR EH-A4ERTD EH-A64DR EH-A64EDR EH-A6EAN EH-A6ERTD EH-AX44 EH-AX8H EH-AX8I EH-AX8IO EH-AX8V EH-AXH8M EH-AY22 EH-AY2H EH-AY4H EH-AY4I EH-AY4V EH-AYH8M EH-BS11 EH-BS3 EH-BS5 EH-BS8 EH-CB10 EH-CBLCU EHCBLIN32 EHCBLOUT32NPN 2 - 22 2 - 22 2-2 2-9 2-9 1-7 1-7 1-8 1-7 1-7 1-7 1-7 1-7 1-8 1-7 1-8 1-7 1-8 1-8 1-8 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13 1 - 13 1 - 11 1 - 11 1 - 11 1 - 11 1 - 11 1 - 12 1 - 12 1 - 12 EHCBLOUT32PNP EH-CPU104 EH-CPU208 EH-CPU316 EH-CPU516 EH-CPU548 EH-CU EH-CUE EH-D10DR EH-D10DTN EH-D10DTP EH-D14DR EH-D14DTN EH-D14DTP EH-D14DTPS EH-D14EDR EH-D14EDTN EH-D14EDTP EH-D14EDTPS EH-D16ED EH-D16ER EH-D16ETN EH-D16ETPS EH-D20DR EH-D20DTN EH-D20DTPS EH-D23DRP EH-D28DR EH-D28DRP EH-D28DTN EH-D28DTP EH-D28DTPS EH-D28EDR EH-D28EDTN EH-D28EDTP EH-D28EDTPS EH-D40DR EH-D40DTN EH-D40DTPS EH-D4ERTD EH-D64DR EH-D64DT EH-D64DTPS EH-D64EDR EH-D64EDT EH-D64EDTPS EH-D6EAN EH-D6ERTD EH-D8ED EH-D8EDR EH-D8EDTN EH-D8EDTPS EH-D8ER EH-D8ETN EH-D8ETPS EH-DUM EH-ETH2 EH-IOCD EH-IOCH EH-IOCP EH-LINK EH-MBAT EH-MBATL EH-MBATLC EH-MCB01 EH-MCB05 EH-MCB10 EH-MEMD EH-MEMP EH-OB232 EH-OB232 EH-OB485 EH-OB485 EH-OBMEM EH-OBUSB EH-OLINK EH-POS EH-POS4 EH-PSA EH-PSD EH-PT4 EHRLY16 EH-RMD 1 - 12 1 - 11 1 - 11 1 - 11 1 - 11 1 - 11 1 - 12 1 - 12 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-7 1-8 1-8 1-8 1-8 1-7 1-7 1-7 1-8 1-7 1-7 1-7 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1 - 13 1 - 11 1 - 11 1 - 11 1 - 11 1 - 11 1-9 1-9 1-9 1-8 1-8 1-8 1 - 11 1 - 11 1-8 1-9 1-8 1-9 1-9 1-9 1 - 11 1 - 13 1 - 13 1 - 11 1 - 11 1 - 13 1 - 12 1 - 11 B C D E For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included PAGE CAT. NO. PAGE EH-RMP EH-SIO EH-TC8 EHTRM32 EH-XA16 EH-XAH16 EH-XD16 EH-XD32 EH-XD32E EH-XD64 EH-XD8 EH-XDL16 EH-XDL32 EH-XDL32E EH-YR12 EH-YR16 EH-YR8B EH-YS16 EH-YS4 EH-YT16 EH-YT32 EH-YT32E EH-YT64 EH-YT8 EH-YTP16 EH-YTP16S EH-YTP32 EH-YTP32E EH-YTP64 EH-YTP8 EM 40 GF KIT EM411O1S EM41D1O1S EM41DS1O1S EM41R1O1S EM41TL1O1S EM954K1O1S EM95D1O1S EM95DD1O1S EM95DS1O1S EM95R1O1S EM95TK1O1S EM95TL1O1S EM95W1O1S EMX3-0023B-V4-C1-H EMX3-0023B-V4-C1-H EMX3-0023B-V4-C2-H EMX3-0023B-V4-C2-H EMX3-0023B-V7-C1-H EMX3-0023B-V7-C1-H EMX3-0023B-V7-C2-H EMX3-0023B-V7-C2-H EMX3-0043B-V4-C1-H EMX3-0043B-V4-C1-H EMX3-0043B-V4-C2-H EMX3-0043B-V4-C2-H EMX3-0043B-V7-C1-H EMX3-0043B-V7-C1-H EMX3-0043B-V7-C2-H EMX3-0043B-V7-C2-H EMX3-0050B-V4-C1-H EMX3-0050B-V4-C1-H EMX3-0050B-V4-C2-H EMX3-0050B-V4-C2-H EMX3-0050B-V7-C1-H EMX3-0050B-V7-C1-H EMX3-0050B-V7-C2-H EMX3-0050B-V7-C2-H EMX3-0053B-V4-C1-H EMX3-0053B-V4-C1-H EMX3-0053B-V4-C2-H EMX3-0053B-V4-C2-H EMX3-0053B-V7-C1-H EMX3-0053B-V7-C1-H EMX3-0053B-V7-C2-H EMX3-0053B-V7-C2-H EMX3-0076B-V4-C1-H EMX3-0076B-V4-C1-H EMX3-0076B-V4-C2-H EMX3-0076B-V4-C2-H EMX3-0076B-V7-C1-H EMX3-0076B-V7-C1-H EMX3-0076B-V7-C2-H 1 - 11 1 - 11 1 - 13 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 1 - 12 2 - 22 2 - 12 2 - 12 2 - 12 2 - 12 2 - 12 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 EMX3-0076B-V7-C2-H EMX3-0097B-V4-C1-H EMX3-0097B-V4-C1-H EMX3-0097B-V4-C2-H EMX3-0097B-V4-C2-H EMX3-0097B-V7-C1-H EMX3-0097B-V7-C1-H EMX3-0097B-V7-C2-H EMX3-0097B-V7-C2-H EMX3-0100B-V4-C1-H EMX3-0100B-V4-C1-H EMX3-0100B-V4-C2-H EMX3-0100B-V4-C2-H EMX3-0100B-V7-C1-H EMX3-0100B-V7-C1-H EMX3-0100B-V7-C2-H EMX3-0100B-V7-C2-H EMX3-0105B-V4-C1-H EMX3-0105B-V4-C1-H EMX3-0105B-V4-C2-H EMX3-0105B-V4-C2-H EMX3-0105B-V7-C1-H EMX3-0105B-V7-C1-H EMX3-0105B-V7-C2-H EMX3-0105B-V7-C2-H EMX3-0145B-V4-C1-H EMX3-0145B-V4-C1-H EMX3-0145B-V4-C2-H EMX3-0145B-V4-C2-H EMX3-0145B-V7-C1-H EMX3-0145B-V7-C1-H EMX3-0145B-V7-C2-H EMX3-0145B-V7-C2-H EMX3-0170B-V4-C1-H EMX3-0170B-V4-C1-H EMX3-0170B-V4-C2-H EMX3-0170B-V4-C2-H EMX3-0170B-V7-C1-H EMX3-0170B-V7-C1-H EMX3-0170B-V7-C2-H EMX3-0170B-V7-C2-H EMX3-0200B-V4-C1-H EMX3-0200B-V4-C1-H EMX3-0200B-V4-C2-H EMX3-0200B-V4-C2-H EMX3-0200B-V7-C1-H EMX3-0200B-V7-C1-H EMX3-0200B-V7-C2-H EMX3-0200B-V7-C2-H EMX3-0220B-V4-C1-H EMX3-0220B-V4-C1-H EMX3-0220B-V4-C2-H EMX3-0220B-V4-C2-H EMX3-0220B-V7-C1-H EMX3-0220B-V7-C1-H EMX3-0220B-V7-C2-H EMX3-0220B-V7-C2-H EMX3-0255B-V4-C1-H EMX3-0255B-V4-C1-H EMX3-0255B-V4-C2-H EMX3-0255B-V4-C2-H EMX3-0255B-V7-C1-H EMX3-0255B-V7-C1-H EMX3-0255B-V7-C2-H EMX3-0255B-V7-C2-H EMX3-0255C-V4-C1-H EMX3-0255C-V4-C1-H EMX3-0255C-V4-C2-H EMX3-0255C-V4-C2-H EMX3-0255C-V7-C1-H EMX3-0255C-V7-C1-H EMX3-0255C-V7-C2-H EMX3-0255C-V7-C2-H EMX3-0350B-V4-C1-H EMX3-0350B-V4-C1-H EMX3-0350B-V4-C2-H EMX3-0350B-V4-C2-H EMX3-0350B-V7-C1-H EMX3-0350B-V7-C1-H EMX3-0350B-V7-C2-H EMX3-0350B-V7-C2-H EMX3-0360C-V4-C1-H EMX3-0360C-V4-C1-H 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au CAT. NO. EMX3-0360C-V4-C2-H EMX3-0360C-V4-C2-H EMX3-0360C-V7-C1-H EMX3-0360C-V7-C1-H EMX3-0360C-V7-C2-H EMX3-0360C-V7-C2-H EMX3-0380C-V4-C1-H EMX3-0380C-V4-C1-H EMX3-0380C-V4-C2-H EMX3-0380C-V4-C2-H EMX3-0380C-V7-C1-H EMX3-0380C-V7-C1-H EMX3-0380C-V7-C2-H EMX3-0380C-V7-C2-H EMX3-0425B-V4-C1-H EMX3-0425B-V4-C1-H EMX3-0425B-V4-C2-H EMX3-0425B-V4-C2-H EMX3-0425B-V7-C1-H EMX3-0425B-V7-C1-H EMX3-0425B-V7-C2-H EMX3-0425B-V7-C2-H EMX3-0430C-V4-C1-H EMX3-0430C-V4-C1-H EMX3-0430C-V4-C2-H EMX3-0430C-V4-C2-H EMX3-0430C-V7-C1-H EMX3-0430C-V7-C1-H EMX3-0430C-V7-C2-H EMX3-0430C-V7-C2-H EMX3-0500B-V4-C1-H EMX3-0500B-V4-C1-H EMX3-0500B-V4-C2-H EMX3-0500B-V4-C2-H EMX3-0500B-V7-C1-H EMX3-0500B-V7-C1-H EMX3-0500B-V7-C2-H EMX3-0500B-V7-C2-H EMX3-0580B-V4-C1-H EMX3-0580B-V4-C1-H EMX3-0580B-V4-C2-H EMX3-0580B-V4-C2-H EMX3-0580B-V7-C1-H EMX3-0580B-V7-C1-H EMX3-0580B-V7-C2-H EMX3-0580B-V7-C2-H EMX3-0620C-V4-C1-H EMX3-0620C-V4-C1-H EMX3-0620C-V4-C2-H EMX3-0620C-V4-C2-H EMX3-0620C-V7-C1-H EMX3-0620C-V7-C1-H EMX3-0620C-V7-C2-H EMX3-0620C-V7-C2-H EMX3-0650C-V4-C1-H EMX3-0650C-V4-C1-H EMX3-0650C-V4-C2-H EMX3-0650C-V4-C2-H EMX3-0650C-V7-C1-H EMX3-0650C-V7-C1-H EMX3-0650C-V7-C2-H EMX3-0650C-V7-C2-H EMX3-0700B-V4-C1-H EMX3-0700B-V4-C1-H EMX3-0700B-V4-C2-H EMX3-0700B-V4-C2-H EMX3-0700B-V7-C1-H EMX3-0700B-V7-C1-H EMX3-0700B-V7-C2-H EMX3-0700B-V7-C2-H EMX3-0790C-V4-C1-H EMX3-0790C-V4-C1-H EMX3-0790C-V4-C2-H EMX3-0790C-V4-C2-H EMX3-0790C-V7-C1-H EMX3-0790C-V7-C1-H EMX3-0790C-V7-C2-H EMX3-0790C-V7-C2-H EMX3-0820B-V4-C1-H EMX3-0820B-V4-C1-H EMX3-0820B-V4-C2-H EMX3-0820B-V4-C2-H EMX3-0820B-V7-C1-H EMX3-0820B-V7-C1-H GST not included PAGE 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 Alphanumeric Index CAT. NO. 5 Alphanumeric Index 6 CAT. NO. PAGE CAT. NO. PAGE CAT. NO. PAGE EMX3-0820B-V7-C2-H EMX3-0820B-V7-C2-H EMX3-0920B-V4-C1-H EMX3-0920B-V4-C1-H EMX3-0920B-V4-C2-H EMX3-0920B-V4-C2-H EMX3-0920B-V7-C1-H EMX3-0920B-V7-C1-H EMX3-0920B-V7-C2-H EMX3-0920B-V7-C2-H EMX3-0930C-V4-C1-H EMX3-0930C-V4-C1-H EMX3-0930C-V4-C2-H EMX3-0930C-V4-C2-H EMX3-0930C-V7-C1-H EMX3-0930C-V7-C1-H EMX3-0930C-V7-C2-H EMX3-0930C-V7-C2-H EMX3-1000B-V4-C1-H EMX3-1000B-V4-C1-H EMX3-1000B-V4-C2-H EMX3-1000B-V4-C2-H EMX3-1000B-V7-C1-H EMX3-1000B-V7-C1-H EMX3-1000B-V7-C2-H EMX3-1000B-V7-C2-H EMX3-1200C-V4-C1-H EMX3-1200C-V4-C1-H EMX3-1200C-V4-C2-H EMX3-1200C-V4-C2-H EMX3-1200C-V7-C1-H EMX3-1200C-V7-C1-H EMX3-1200C-V7-C2-H EMX3-1200C-V7-C2-H EMX3-1410C-V4-C1-H EMX3-1410C-V4-C1-H EMX3-1410C-V4-C2-H EMX3-1410C-V4-C2-H EMX3-1410C-V7-C1-H EMX3-1410C-V7-C1-H EMX3-1410C-V7-C2-H EMX3-1410C-V7-C2-H EMX3-1600C-V4-C1-H EMX3-1600C-V4-C1-H EMX3-1600C-V4-C2-H EMX3-1600C-V4-C2-H EMX3-1600C-V7-C1-H EMX3-1600C-V7-C1-H EMX3-1600C-V7-C2-H EMX3-1600C-V7-C2-H ES13SB101S ES 40 GF KIT ES41 ES41D1O1S ES41DS1O1S ES41R1O1S ES41Z 101S ES 60 GF ES61SR101S ES954K1O1S ES95AZ101S ES95AZ20 ES95D1O1S ES95DD1O1S ES95DS1O1S ES95R1O1S ES95SB101S ES95SB20 ES95T5C101S ES95TK1O1S ES95TL1O1S ES95W1O1S ETHCONV2 ETHCONV3 EX55400GWNBB EX55400NBB EX55401NBB 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 3 - 16 3 - 17 3 - 16 3 - 17 3 - 18 3 - 19 3 - 18 3 - 19 2-4 2 - 22 2 - 12 2 - 12 2 - 12 2 - 12 2 - 21 2 - 22 2 - 10 2 - 11 2-2 2-2 2 - 11 2 - 11 2 - 11 2 - 11 2-4 2-4 2-4 2 - 11 2 - 11 2 - 11 1 - 46 1 - 46 2 - 14 2 - 14 2 - 14 G21104401700 G21205501700 G21205502700 G21305511700 G21305521700 1 - 43 1 - 43 1 - 43 1 - 44 1 - 44 G21404421700 G21404422700 G21405510700 G21405520700 G32101111 G32101112 G32101113 G32101161 G32385138230 G34105501 G34205501024 G34205501115 G34205501230 G34205501800 G34205502024 G34205502115 G34205502230 G34205502800 G34296470024 G34296470115 G34296470230 G34296470800 G34301149024 G34301149115 G34301149230 G34301149800 G34302249024 G34302249115 G34302249230 G34302249824 G34304249024 G34304249115 G34304249230 G34304249824 G34304443024 G34304443115 G34304443230 G34304443824 G34304445024 G34304445115 G34304445230 G34305511024 G34305511115 G34305511230 G34305511800 G34305521024 G34305521115 G34305521230 G34305521800 G34305545024 G34305545115 G34305545230 G34396470024 G34396470115 G34396470230 G34396470800 G34404443024 G34404443115 G34404443230 G34404443824 G34485134230 G34485234230 G34485238230 G34850000 G34860058230 G34900000024 G34900000115 G34900000230 G34900000824 G34910000024 G34910000115 G34910000230 G34910040024 G34910040115 G34910040230 G34910090024 G34910090115 G34910090230 G34920000230 G34930000230 G34960000700 G34960001700 G34960002700 1 - 45 1 - 45 1 - 45 1 - 45 1 - 46 1 - 46 1 - 46 1 - 46 1 - 46 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 46 1 - 46 1 - 46 1 - 46 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 44 1 - 46 1 - 46 1 - 46 1 - 46 1 - 45 1 - 45 1 - 45 1 - 45 1 - 44 1 - 44 1 - 44 1 - 47 1 - 46 1 - 42 1 - 42 1 - 42 1 - 42 1 - 46 1 - 46 1 - 46 1 - 46 1 - 46 1 - 46 1 - 46 1 - 46 1 - 46 1 - 46 1 - 46 1 - 42 1 - 42 1 - 42 G34960003700 G34960004700 G34960005700 G34960006700 G34960007700 G34960008700 G34960009700 G34960010700 G34960011700 G34960012700 G38000015230 G38000015800 G38000016230 G38000016800 G38000036230 G38000036800 G38001015230 G38001015800 G38001016230 G38001016800 G38001036230 G38001036800 G38305543024 G38305543115 G38305543230 G38305543824 G38900014230 G38900014800 G38910020230 G38910021230 G38910050230 G38910051230 G38910052230 G38910120230 G40855562 G41855531 G42484134724 G43111120 G44207401230 G44207401724 G50101106 G50102206 G54606606024 G54606606115 G54606606230 G61101145 G61101145-1 G63910240 G81103394 G81104406 G81104407 G81112211 G81113315 G81452574 G81864407703 G82104406 G82452574 G82864406703 G85101101 G85102201 G85103301 G86111010 G88101102 G88104401 G88301143 G88405521 G89101101 G89101101-G G89101127 G89102116 G89102217 G89111010 GAP1605 GF 101S GF 10SD10S GF2 10S10S GF2 20S20S GF 2O2S GFM 101S GFM 202S GF POTI_OHM GFS 101S GFS 10SD10S 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 42 1 - 44 1 - 44 1 - 44 1 - 44 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 47 1 - 47 1 - 44 1 - 46 1 - 43 1 - 43 1 - 43 1 - 43 1 - 47 1 - 47 1 - 47 1 - 43 1 - 43 1 - 46 1 - 46 1 - 45 1 - 45 1 - 46 1 - 46 1 - 45 1 - 45 1 - 45 1 - 45 1 - 45 1 - 45 1 - 45 1 - 45 1 - 46 1 - 43 1 - 43 1 - 44 1 - 45 1 - 43 1 - 43 1 - 43 1 - 43 1 - 43 1 - 46 1 - 47 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 G For further information please contact Sales 1300 NHP NHP or visit nhp.com.au GST not included PAGE CAT. NO. PAGE GFS1SD 10VD GFS 202S GFS2 10S/10S GFS2 20S/20S GFS2SD 20VD GFSM 1O1S GFSM 2O2S GFS POTI_OHM GH34404412 GH34850000724 GH64404412 GHTU8 GPS-B015-FN4-VD GPS-B025-FN4-VD GPS-B045-FN4-VD GT01-C30R2-6P GT1030HBD2 GTI50 GTU8 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 2 - 22 1 - 45 1 - 46 1 - 45 1 - 47 2 - 23 2 - 23 2 - 23 1-5 1-5 1 - 46 1 - 47 HSSI4101S HSSI420 2-7 2-7 IM0126044 IM0126084 IM0126124 IM0126144 IM0126164 IM0126204 IM0126244 IM0126284 IM0126324 IM0126364 IM0126404 IM0126444 IM0127324 IM0127364 IM0127404 IM0127444 6 X IM0141724 6 X IMO141782 6 X IM0141784 IMO126004 IPS-B026-FN4-VD IPS-B036-FN4-VD IPS-B046-FN4-VD 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 35 3 - 45 3 - 35 2 - 23 2 - 23 2 - 23 LIBAT-H 1 - 13 MC30 MC4 MC56 MF1C 2-6 2-7 2-6 2 - 20 PCS-030-480V PCS-030-480V-024V PCS-037-480V PCS-037-480V-024V PCS-043-480V PCS-043-480V-024V PCS-060-480V PCS-060-480V-024V PCS-085-480V PCS-085-480V-024V PCS-23-CI23 PCS-25S-CC25 PCS-37-CI37 PCS-PA-01 PCS-PA-10 PCS-PA-11 PCS-PA-20 PCV-064 PIM-DN-01 PIM-DN-01 PIM-DN-01 PIM-MB-01 PIM-MB-01 PIM-MB-01 PIM-PA-01 PIM-PA-01 PIM-PB-01 PIM-PB-01 PIM-PB-01 PIM-RZ-01 PIM-RZ-01 PIM-USB-01 PROTFILM10 PROTFILM12 PROTFILM6 PS21LMS11P0M00 PS21LMS11PRM00 PS21LMS11R1M00 PS21LMS11RTM00 PS21LMT11P0M00 PS21LMT11PRM00 PS21LMT11R1M00 PS21LMT11RTM00 PS31LMS11P0T00 PS31LMS11PRT00 PS31LMS11R1T00 PS31LMS11RTT00 PS31LMS11RVT00 PS31LMT11P0T00 PS31LMT11PRT00 PS31LMT11R1T00 PS31LMT11RTT00 PS31LMT11RVT00 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-8 3 - 11 3 - 20 3-8 3 - 11 3 - 20 3-8 3 - 11 3-8 3 - 11 3 - 20 3-8 3 - 11 3 - 20 1 - 54 1 - 54 1 - 54 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11 2 - 11 2 - 12 2 - 12 2 - 12 2 - 12 2 - 12 2 - 12 2 - 12 2 - 12 2 - 12 2 - 12 NBAFP NBAG NBBFP NBBG NO2242 NO2243 NO2551 NO2556 NSC13DB24DA NSC13DB24DC 2 - 15 2 - 15 2 - 15 2 - 15 2 - 15 2 - 15 2 - 15 2 - 15 2 - 20 2 - 20 PCNET PCNET PCNET PCP-064-480V PCP-064-600V PCP-147-480V PCP-147-600V PCS-003-480V PCS-003-480V-024V PCS-009-480V PCS-009-480V-024V PCS-016-480V PCS-016-480V-024V PCS-019-480V PCS-019-480V-024V PCS-025-480V PCS-025-480V-024V 1 - 50 1 - 51 1 - 54 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 3-6 RCM-02 RCM-02 RCSI56101S5M RCSI56205M RCSIM30101S5M RCSIM30205M RE2643560 RE2644100 RE2644200 RE2644400 RE3063750 RE3083500 RE3083500 RE3093500 RE3113500 RE3483150 RE3483200 RE3483250 RE3483500 RE3503500 RE3762330 RE3763100 RE3783500 RE4022660 RE4023100 RE4053200 RE4163150 RE4293100 RE4462120 3-8 3 - 11 2-6 2-6 2-6 2-6 3 - 26 3 - 26 3 - 26 3 - 26 3 - 26 3 - 26 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 H I L M N P R For further information please contact Sales 1300 NHP NHP or visit nhp.com.au CAT. NO. RE4462160 RE4462600 RE4561800 RE4562120 RE4562160 RE4562240 RE4562500 RVT5009 PAGE 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 1 - 50 S900 SC207A0101 SM 0001 2ST BA2K2 SM 0001 4T BA2K2 SM 0002 2ST BA2K2 SM 0002 4T BA2K2 SM 0003 2ST BA2K2 SM 0003 4T BA2K2 SM 0005 2ST BA2K2 SM 0005 4T BA2K2 SM 0007 2ST BA2K2 SM 0007 4T BA2K2 SM 0011 2ST BA2K2 SM 0011 4T BA2K2 SM 0014 2ST BA2K2 SM 0014 4T BA2K2 SM 0017 2ST BA2K2 SM 0017 4T BA2K2 SM 0020 2ST BA2K2 SM 0020 4T BA2K2 SM 0025 2ST BA2K2 SM 0025 4T BA2K2 SM 0030 2ST BA2K2 SM 0030 4T BA2K2 SMDMK SME00022ST SME00024T SME00032ST SME00034T SME00072ST SME00074T SME00112ST SME00142ST SME00144T SN 0001 2S XB K2 SN 0002 2S XB K2 SN 0003 2S XB K2 SN 0005 2S XB K2 SNMCANOP SNMCTLNT SNMDEVNT SNMETHNT SNMINTBS SP 0313 4TXA2K0 SP 0367 4TXA2K0 SP 0402 4TXA2K0 SP 0457 4TXA2K0 SP 0524 4TXA2K0 SP 0598 4TXA2K0 SP 0748 4TXA2K0 SP 0831 4TXA2K0 SP 0964 4TXA2K0 SP 1130 4TXA2K0 SP 1296 4TXA2K0 SP 0003 6TBA2K2 SP 0004 6TBA2K2 SP 0005 4TBA2K2 SP 0005 4TBA2K5 SP 0006 6TBA2K2 SP 0007 4TBA2K2 SP 0007 4TBA2K5 SP 0009 4TBA2K2 SP 0009 4TBA2K5 SP 0011 4TBA2K2 SP 0011 4TBA2K5 SP 0012 6TBA2K2 SP 0014 4TBA2K2 SP 0014 4TBA2K5 SP 0016 4TBA2K2 SP 0016 4TBA2K5 SP 0017 4TBA2K2 SP 0017 4TBA2K5 SP 0018 6TBA2K2 SP 0019 6TBA2K2 SP 0020 4TBA2K2 2-9 1 - 48 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 25 3 - 26 3 - 26 3 - 26 3 - 26 3 - 26 3 - 26 3 - 26 3 - 26 3 - 26 3 - 26 3 - 24 3 - 24 3 - 24 3 - 24 3 - 26 3 - 26 3 - 26 3 - 26 3 - 26 3 - 33 3 - 33 3 - 33 3 - 33 3 - 33 3 - 33 3 - 33 3 - 33 3 - 33 3 - 33 3 - 33 3 - 45 3 - 45 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 33 3 - 34 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 33 3 - 34 3 - 33 3 - 34 3 - 45 3 - 45 3 - 33 GST not included S Alphanumeric Index CAT. NO. 7 Alphanumeric Index 8 CAT. NO. PAGE SP 0020 4TBA2K5 SP 0021 6TBA2K2 SP 0022 6TBA2K2 SP 0024 6TBA2K2 SP 0025 4TBA2K2 SP 0025 4TBA2K5 SP 0030 4TBA2K2 SP 0030 4TBA2K5 SP 0032 6TBA2K2 SP 0034 4TBA2K2 SP 0034 4TBA2K5 SP 0036 4TBA2K2 SP 0036 4TBA2K5 SP 0040 4TBA2K2 SP 0040 4TBA2K5 SP 0042 6TBA2K2 SP 0049 4TBA2K2 SP 0049 4TBA2K5 SP 0051 6TBA2K2 SP 0060 4TBA2K2 SP 0060 4TBA2K5 SP 0062 6TXA2K0 SP 0067 4TBA2K2 SP 0067 4TBA2K5 SP 0069 6TXA2K0 SP 0074 4TBA2K2 SP 0074 4TBA2K5 SP 0076 6TXA2K0 SP 0086 4TBA2K2 SP 0086 4TBA2K5 SP 0088 6TXA2K0 SP 0113 4TBA2K2 SP 0113 4TBA2K5 SP 0129 4TBA2K2 SP 0129 4TBA2K5 SP 0131 6TXA2K0 SP 0150 4TBA2K2 SP 0150 4TBA2K5 SP 0162 4TBA2K2 SP 0162 4TBA2K5 SP 0164 6TXA2K0 SP 0180 4TXA2K0 SP 0181 6TXA2K0 SP 0201 6TXA2K0 SP 0202 4TXA2K0 SP 0217 4TXA2K0 SP 0218 6TXA2K0 SP 0250 6TXA2K0 SP 0259 6TXA2K0 SP 0260 4TXA2K0 SP 0290 6TXA2K0 SP 0312 6TXA2K0 SP 0314 6TXA2K0 SP 0366 6TXA2K0 SP 0368 6TXA2K0 SP 0399 6TXA2K0 SP 0401 6TXA2K0 SP 0457 6TXA2K0 SP 0524 6TXA2K0 SP 0598 6TXA2K0 SP 0748 6TXA2K0 SP 1130 6TXA2K0 SP 1296 6TXA2K0 SP500- XX SP501- XX SP502- XX SPUSB SPUSB SRM21RT2 ST14-10/1S ST14-20 ST14 B1 ST14 B3 ST14 B5 ST6110/1S ST6120 ST61 B1 ST61 B5 STM295202SA STM295202SR STM295 B1 STM295 B5 SYCON 3 - 34 3 - 45 3 - 45 3 - 45 3 - 33 3 - 34 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 33 3 - 34 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 33 3 - 34 3 - 45 3 - 33 3 - 34 3 - 33 3 - 34 3 - 45 3 - 33 3 - 45 3 - 45 3 - 33 3 - 33 3 - 45 3 - 45 3 - 45 3 - 33 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 45 3 - 48 3 - 48 3 - 48 3 - 26 3 - 48 2 - 20 2-2 2-2 2-2 2-2 2-2 2-3 2-3 2-3 2-3 2-5 2-5 2-5 2-5 1 - 13 CAT. NO. PAGE TQ4410101YU TQ441 01/01 YUR TQ441 01/01 YUR 137 TQ441 01/01 YUR 157 TQZ-73 20 WVD TQZS-70 10/1S VD TQZS70KIT10M TQZS-71 10/1SWVD TQZS-71 20 WVD TQZS71KIT20M TQZS-73 10/1SWVD TQZS73KIT50M TQZS-75 10/1S WVD TQZS-75 20/2S WVD TQZS75KIT50M TQZS-80 20/2S WVD TQZS80KIT50M TQZSTS150N TQZSTS250N 2 - 21 2-9 2-9 2-9 2-9 2-9 2-8 2-9 2-9 2-8 2-9 2-8 2-9 2-9 2-8 2-9 2-8 2-9 2-9 USB-COM USB-COM USB-COM USB-COM 1-4 1-5 1-9 1 - 13 VFBC VT050 VT060 VT150W VT150W DP VT155W VT155W 000DP VT155W 000ET VT160W VT160W DP VT170W A VT185W VT185W 000ET VT190W A VT190W AP VT300W A VT300W AP VT310W A VT310W AP VT320W A VT320W AP VT330W APM VT330W APT VT505H VT505W VT505W 000ET VT505W DP VT515W VT515W 000DP VT515W 000ET VT525H VT525W VT525W 000DP VT525W 000ET VT555W A VT555W AP VT555W AP0DP VT560W A VT560W A0M VT565W A VT565W A0M VT565W AP VT565W APM VT580W 0PTDP VT580W 0PTET VT580W APT VT585W BPT VT585W BPTDP VT585W BPTET VT595W 0PTDP VT595W 0PTET VT595W APT VT5ESABUS VTBUTTONCELL VTBUTTONCELL VTBUTTONCELL VTCBL2515 2 - 15 1 - 50 1 - 50 1 - 50 1 - 50 1 - 52 1 - 52 1 - 52 1 - 50 1 - 50 1 - 50 1 - 52 1 - 52 1 - 50 1 - 50 1 - 51 1 - 51 1 - 51 1 - 51 1 - 51 1 - 51 1 - 51 1 - 51 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 52 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 53 1 - 50 1 - 50 1 - 51 1 - 54 1 - 54 T U V For further information please contact Sales 1300 NHP NHP or visit nhp.com.au CAT. NO. PAGE VTCBL2545 VTCBLADP VTCBLXFR VTPROFI/DP VTPROFI/DP VTPROFI/DP VTWINLITE VTWINLITE VTWINLITE 1 - 54 1 - 54 1 - 54 1 - 50 1 - 51 1 - 54 1 - 50 1 - 51 1 - 54 WW0030460 WW1420000 3 - 38 3 - 26 XCSA120BC XCSA120CB XCSA120DC XCSB150C XCSB150D XCSBC XCSBD XCSD15B XCSD30C XCSD50B XCSD70C XCSF120B XCSF120CP XCSF120D XCSF240B XCSF240CP XCSF240D XCSF500C XCSF85CP XCSG2400C XCSG240C XCSG42 XCSG500C XCSG720C XCSL120C XCSL240C XCSL85C XCSL85C XCSP120C XCSP120C XCSP120C XCSP85C XCSP85C XCSP85C XCSP85C XCSP85C 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1 - 68 1-4 1 - 68 1-4 1-9 1 - 13 1-9 1 - 13 1 - 50 1 - 51 1 - 54 ZS23211 ZS73SR101S ZS75SR101S ZS75SR202S ZS90SR10S10S ZZ0063010 ZZ0063020 ZZ0063040 ZZ0063050 ZZ0063072 ZZ0095210 ZZ0095699 ZZ0095700 ZZ0095834 ZZ0095850 ZZ0101790 ZZ0101812 ZZ0101820 ZZ0101840 ZZ0102402 ZZ0102404 ZZ0102406 ZZ0112010 ZZ0112020 ZZ0112030 ZZ0112040 ZZ0112045 ZZ0112050 ZZ0112060 ZZ0112070 ZZ0121920 ZZ4590010 ZZ4590010 2 - 22 2 - 10 2 - 10 2 - 10 2 - 10 3 - 38 3 - 38 3 - 38 3 - 38 3 - 38 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 35 3 - 48 3 - 46 3 - 47 GST not included W X Z PAGE ZZ4600030 ZZ4600040 ZZ4600050 ZZ4600060 ZZ4600070 ZZ4600080 ZZ4600085 ZZ4600100 3 - 26 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 3 - 48 For further information please contact Sales 1300 NHP NHP or visit nhp.com.au Alphanumeric Index CAT. NO. GST not included 9 With NHP’s Price Lists available for download online, you can now access product information anytime, anywhere! Scan the QR code below or go to www.nhp.com.au to download the latest NHP catalogues and price lists. QR CODE WEB HOW TO ACTIVATE YOUR QR CODES 1. Download 2. Scan 3. View In order to scan one of the QR Codes you need to download a QR Code reader app to your smartphone. Try simply searching ‘QR Code’ in your app store. Open your QR Code reader app and point the device’s camera at the relevant QR code. Once scanned the QR Code will automatically open the relevant location. Darwin Cairns Townsville 13 11 12 Rockhampton 14 15 Toowoomba 9 Perth 7 10 Adelaide NHP Branch Offices NHP Resident Sales Staff 19 6 22 Brisbane 16 21 23 20 Newcastle Canberra Sydney Albury Wollongong 18 2 8 4 1 Melbourne Auckland 3 5 Hamilton Laverton Dandenong New Plymouth Launceston 17 24 Napier Wellington Hobart Christchurch Dunedin Australian Branches Victoria Richmond Laverton Dandenong Albury / Wodonga Tasmania Hobart Launceston New South Wales Sydney Newcastle Canberra Wollongong Western Australia Perth Northern Territory Darwin Queensland Brisbane Townsville Rockhampton Toowoomba Cairns South Australia Adelaide New Zealand Branches North Island Auckland Hamilton Napier Wellington New Plymouth 34 South Island Christchurch Dunedin Australian Regional Representation 1 2 3 4 5 6 7 8 9 10 11 12 Ballarat Bendigo Geelong Shepparton Gippsland Mildura Whyalla Mt Gambier Kalgoorlie Bunbury Karratha Port Hedland 13 14 15 16 17 18 19 20 21 22 23 Mackay Gladstone Sunshine Coast Gold Coast Griffith Wagga Wagga Dubbo Gosford Coffs Harbour Tamworth Lithgow New Zealand Regional Representation 24 Bay of Plenty AUSTRALIA nhp.com.au SALES 1300 NHP NHP VICTORIA Melbourne 43-67 River Street Richmond VIC 3121 Tel +61 3 9429 2999 Laverton 104-106 William Angliss Drive Laverton North VIC 3026 Tel +61 3 9368 2901 Albury / Wodonga 847 Ramsden Drive Albury NSW 2640 Tel +61 2 6049 0600 Dandenong 40-42 Cyber Loop Dandenong South VIC 3175 Tel +61 3 8773 6400 TASMANIA Hobart Unit 2 65 Albert Street Moonah TAS 7009 Tel +61 3 6228 9575 Launceston Unit 3 13-17 Merino Street Kings Meadows TAS 7249 Tel +61 3 6345 2600 NEW SOUTH WALES QUEENSLAND Sydney 30-34 Day Street North Silverwater NSW 2128 Tel +61 2 9748 3444 Brisbane 16 Riverview Place Murarrie QLD 4172 Tel +61 7 3909 4999 Newcastle 575 Maitland Road Mayfield West NSW 2304 Tel +61 2 4960 2220 Wollongong 34 Industrial Road Unanderra NSW 2526 Tel +61 2 4272 5763 ACT Canberra Unit 1 187 Gladstone Street Fyshwick ACT 2609 Tel +61 2 6280 9888 WESTERN AUSTRALIA Perth 38 Belmont Ave Rivervale WA 6103 Tel +61 8 9277 1777 NORTHERN TERRITORY Darwin 3 Steele Street Winnellie NT 0820 Tel +61 8 8947 2666 NHP Electrical Engineering Products Pty Ltd A.B.N. 84 004 304 812 NPLISTDC © Copyright NHP 2013 Townsville 5 Leyland Street Garbutt QLD 4814 Tel +61 7 4779 0700 Rockhampton 1 Lawson Street Parkhurst QLD 4702 Tel +61 7 4927 2277 Toowoomba Cnr Carroll Street and Struan Court QLD 4350 Tel +61 7 4634 4799 Cairns Unit 2 1 Bramp Close Portsmith QLD 4870 Tel +61 7 4035 6888 SOUTH AUSTRALIA Adelaide 36-38 Croydon Road Keswick SA 5035 Tel +61 8 8297 9055 NEW ZEALAND nhp-nz.com SALES 0800 NHP NHP PO Box 62-009 Sylvia Park Auckland 1644 New Zealand Auckland 118a Carbine Road Mt Wellington 1060 Tel +64 9 276 1967 Hamilton 78 Rostrevor Street Hamilton 3204 Tel +64 7 849 0257 Napier 126 Taradale Road Onekawa 4110 Tel +64 6 843 6928 New Plymouth 2 Dean Place Waiwhakaiho 4312 Tel 0800 NHP NHP Wellington 52 Victoria Street Lower Hutt 5010 Tel +64 4 570 0634 Christchurch 27 Iversen Terrace Waltham 8011 Tel +64 3 377 4407 Dunedin 30 Fox Street South Dunedin 9012 Tel 0800 NHP NHP