GDS Pole Mounted Disconnectors Up to 52kV General Information The switch for every application The GDS range is a modern switch system with components for different isolation and switching applications in overheadlines and substations. The system is characterised by a high degree of flexibility in order to meet different national standards as well as to meet various customer specifications. The base in the switch system is the phase element. To this component can different accessories be added for having the requested disconnector or switch specification. The switch can be installed in all different pole types, wood, concrete, steel poles or substation structures. Different insulator alternatives The GDS can be supplied with a wide range of different insulators in order to meet different isolation philosofies, enviromental conditions and different standards. The components of the switch system allow for different insulators to be used due to the design with parallel insulators without affecting the base and contact components. As standard can porcelain, outdoor epoxy resin and silicon rubber insulators be offerd. Beside the standard material can also insulators according to customer specifications be used. 2 Technical characteristics Charctersistic Applicable standards Value IEC 62271-102, IEC 60265 Rated voltage 24kV 36kV Impulse withstand voltage Phase-Earth 125kV 170kV Impulse withstand voltage over isolating distance 145kV 195kV Power frequency voltage 1 min wet, Phase-Earth 50kV 70kV Power frequency voltage 1 min wet, over isolating distance 60kV 80kV Rated frequency 50-60Hz 50-60Hz Rated current *) 630A 630A Short time current 25kA 25kA Duration of short time current 3 sec. 3 sec Peak withstand current 62,5kA 62,5kA 5kA 3kA Interupting capacity with the loadbreak heads of mainly active load at rated voltage and cosφ=0,7 630A 400A Interupting capacity with the loadbreak heads of mainly active load at rated voltage and cosφ=0,15 capacitive 25A 16A Interupting capacity with the loadbreak heads of mainly active load at rated voltage and cosφ=0,15 reactive 16A 4A 400A 400A Interupting capacity with breaking whip of mainly active load at rated voltage and cosφ=0,7 25A 16A Interupting capacity with breaking whip of cable and line changing currents at rated voltage 15A 10A Making capacity Ringinterupting capacity with the loadbreak heads of mainly active load at rated voltage and cosφ=0,3 reactive Permissible ice load Up to 20mm Mechanical endurance >2000 operations -50oC to +50oC Temperature range Insulator material Insulator creepage distance Porcelain,Silicon rubber, Outddoor epoxy resin Various for different insulators *) 630A is standard value. Alternative current ratings are 800A, 1250A and 2000A. 3 Phase elements Article No.** Type Insulator material Rated voltage Rated current’ Weight, kg 2862003 GP2G Outdoor epoxy resin 24kV 630A 30 A6737 GP2P Porcelain 24kV 630A 33 A7513 GP2G4 Outdoor epoxy resin 36kV 630A 33 A7332 GP2S Silicon rubber 36kV 630A 36 A7598 GDS36/52-6600 Porcelain 52kV 630A 60 A8268 GDSS26/52-6600 Silicon rubber 52kV 630A 54 *) 630A is the standard current rating. Other rated currents available on request **) Numbers are for sets of three units GP2G GP2S GP2P GDS36/52-6600 GP2G4 GDSS36/52-6600 4 Loadbreaking accessories Breaking whip Article No.* Type 2862006 GBGK1 Rated voltage 12-36kV For Phase element type Weight, kg GP2G,GP2P,GP2S,GP2G4 2,5 GBGK1 Loadbreak head Article No.* Type A6733 GLBD1 A6733-2 GLBD2 Rated voltage For Phase element type Weight, kg 12-24kV GP2G,GP2P,GP2S,GP2G4 12 36kV GP2S, GP2G4, GDS36/52-6600, GDSS36/52-6600 12 GLBD *) Set of three 5 Connecting accessories Extension part Article No.** Type Insulator material Rated voltage Rated current For Phase element type Weight, kg 2862011 GF2G Outdoor epoxy resin 24kV 630A GP2G 18 A6729-2 GF2P Porcelain 24kV 630A GP2P 20 A6729-5 GF2G4 Outdoor epoxy resin 36kV 630A GP2G4 20 2862009 GF2S Silicon rubber 36kV 630A GP2S 19 GF2G Extension Part for integrated surge arrester Article No.** Type Height of surge arrester Rated current For Phase element type Weight, kg 2862123 GF2PI* 630A GP2G,GP2P, GP2S 15 5821934 GF2PI1* 630A GP2G,GP2P, GP2S 15 **) Surge arrester is not included in articel number GF2PI 6 Connecting accessories Cable connection Part Article No.** Rated voltage Rated current Outddor epoxy resin 24kV 630A GP2G 22 GK2P Porcelain 24kV 630A GP2P 23 A6732-5 GK2G4 Outdoor epoxy resin 36kV 630A GP2G4 23 2862014 GK2S Silicon rubber 36kV 630A GP2S 23 Type Insulator material 2862016 GK2G A6732-2 For Phase element type Weight, kg GK2G Cable connection Part for integrated surge arrester Article No.** 2862124 Type Height of surge arrester GK2PI* Rated current For Phase element type 630A GP2G,GP2P, GP2S Weight, kg 14 **) Surge arrester is not included in articel number GK2PI 7 Fuse combinations For RP33 type fuse tubes Article No.** Rated voltage Rated current Outddor epoxy resin 24kV 80A GP2G 21 GS3P Porcelain 24kV 80A GP2P 22 GS3S Silicon rubber 24kV 80A GP2S 22 Type Insulator material 2862037 GS3G A6741-2 2862035 For Phase element type Weight, kg GS3G assembled on GP2G For fuses with dimensions according to DIN 43625 Article No.** Type Insulator material Rated voltage Rated current For Phase element type Weight, kg 2862071 GS5RG Outddor epoxy resin 24kV 20A GP2G 23 2862069 GS5RS Silicon rubber 24kV 20A GP2S 24 GS5Rs assembled on GP2S 8 Connecting accessories Hinge terminal bar and connection bars Article No. Type Weight, kg A6530* GPK 3 A7997 CPAU 0,2 A7335 CSP 0,4 GPK CPAU CSP Cable connection bar Article No. Type A6847* GCCB Weight, kg 2,4 GCCB Connecting clamps Article No.* Type Conductor crossection 16-120mm2 Weight, kg EKN1 2862056 GKG16 Al 0,8 2862057 GKG43 Al 50-240mm2 1 2862058 GKG44 Al 16-120mm2 Cu 10-95mm2 0,8 A3037 EKN1 Cu 10-120mm2 0,4 GKG 9 *) Article number is for set of three Overvoltage protection accessories Spark gaps Article No.** Type Placement For Phase element type Weight, kg 5221927 GHG Horizontal over support insulator GP2G, GP2P 0,5 A6951 GSG1 Horizontal with crossarm bracket GP2G,GP2P, GP2S,GP2G4 10,5 GHG GSG1 10 Overvoltage protection accessories Surge arrester brackets Article No.* Type Placement Weight, kg 2862121 GSAB Attached to base of phaseelement or accessorie 4 2862120 GVP Together with crossarm clamp GRF 3 *) Article number is for set of three GSAB GSAB on cable connection part GVP on crossarm clamp GRF GSAB on phase element GVP 11 Earthing accessories Article No.** Type Placement For Phase element type Weight, kg A7681 EB2 Fixed contact side of phase element GP2G, GP2P 15 A7998 EB3 Fixed contact side of phase element GP2S,GP2G4 16 A8062 EB4 Rocking contact side of phase element GP2G, GP2P 15 A8034-1 GIL6 Mechanical interlock when earth blades installed on both sides of phase element - 2 A3500*) JOPO Earth bolt for connection of portable earthing tool All types 1 A6906 GJP Earth contact for rocking insulator. When disconnector opens, rocking insulator gets earth connected automatically GP2P,GP2G,GP2S 7 *) Article number is for set of 6 pcs **) Article numbers include three earth blades with mechanical interlock. Associated equipment such as phase coupling tubes, operating rods, operating handles must be ordered separately. EB4 EB2 GJK JOPO 12 Handoperating Mechanisms GHM Operating handles Article No. Type Indication label Weight A6731 GHM I-0 4 A6941 GHM2 ON-OFF 4 A6941-J GHM2-J* Earth On-Earth Off 4 A6941/AU GHM/AU** ON-OFF 4 A8215 GHMEI*** I-0 10 *) The GHM2-J are assembled for reversed operation direction **) The A6941/AU has flexible copper leads between the pole bracket and handle ***) Handoperating mechanism with electrical interlock. When ordering indicate voltage for the locking magnet GHMEI Auxillary contacts and accessories Article No. Type Comment Weight A7460 GHMSK 1NO+1NC contact 0,4 A8216 GHMDI 1NO+1NC x2 1 A7459 GHMIV* Interlocking wheel with one slot 0,2 A7459-1 GHMIV-1* Interlocking wheel with double slots 0,2 *) Castell interlocks are not included with the interlocking wheel, but can be supplied on request GHMDI GHMSK Installed on GHM Installed on GHM GHMIV Installed on GHM 13 Handoperating Mechanisms GHS1 Hookstick operating mechanism Article No. A7380 Type GHS1 Weight 8 The GHS1 has a automatic resetting of the latchpin when operated. Accessories Article No. A8327 Type GHSSL Comment Stickoperated safety lock attachment Weight 0,5 14 Operating rods with accessories Operating rods Article No. Description Type Length,mm 2862032 Complete rod set with upper and lower rod.Telescopically adjustable length GMR1 5800-7600 A7435 Complete rod set with upper and lower rod.Telescopically adjustable GMR2 7300-9100 A7352-1 Upper operating rod with fork for connection to the operating lever GMR3 3250 A7352-2 Intermediate operating rod GMR4 3250 A7352-3 Lower operating rod with telescopically length adjustable section GMR5 2000-3800 Telescopical rod set with forks in both ends for connection to hookstick operating mechanism GMR6 2000-3800 Extension rod with coupling socket for operating rods. Including one extra rod guide GFR2 2000 GMR17 3500-5300 A7373 2862034 A8174 Complete operating rod for substation disconnectors GMR6 Operating rod accessories Article No. Type Suitable for crossarm Weight A6734 GMK Operating lever 1 A7635 GMK5 Operating lever for earth blades 1 A6742 GSI Rod insulator up to 24kV 0,5 A7550 GSI2 Rod insulator up to 52kV 1,3 A7354 GRC Rod coupling socket 0,3 A6743 GSS Rod guide 0,7 A7944 GSS2 Rod guide 2,5 GRC GSS GMK GMK5 GSS2 GSI 15 Pole assembling crossarms Crossarms Article No. Type Dimensions Weight 5821911 GFLR1 80x80x2000 19kg 5821912 GFLR2 100x100x2000 25kg A6611-21 GFLR21 100x100x2500 31kg A8000 GFLR24 80x80x2400 22kg Note: The GFLR24 Crossarm have no holes drilled Crossarm assembling parts For single-pole installation Article No. Type Suitable for crossarm Weight 5821919 GFLRME GFLR1&GFLR2 4 A8139-1 GFLRME-1 GFLR21 4 Article No. Type A7962 PBRC Suitable for crossarm GFLR1,GFLR2, GFLR21, GFLR24 Weight 7 Note: The PBRC pole bracket should not be used when conductors are terminated to the crossarm. For H-pole installation Article No. 5821920 Type GFLRMP Suitable for crossarm GFLR1,GFLR2, GFLR21 Weight 2 16 Crossarm assembling accessories Crossarm clamps Article No. Type Suitable for crossarms Weight 2862091 GRF1 Box tubes and C-channels with max dimensions100x130mm (WxH) 0,6 kg 2862092 GRF2 Box tubes and C-channels with max dimensions130x180mm (WxH) 0,7 kg A6915 GRF3 Angle channels with max dimensions 130x180 (WxH) 0,7 kg 17 Mast Head Loadbreaklswitch 24kV,630A Handle operation, epoxy resin insulators Component Type Qty GP2G 1 GPK 1 Loadbreak head GLBD1 1 Phase coupling tube GMA16 1 Crossarm clamps GRF1 3 Operating lever GMK 1 Operating tube GMR2 1 Assembling crossarm GFLR1 1 Operating handle GHM 1 Rod guide GSS 2 Rod insulator GSI 1 Phase element Hinge Terminal bar Ordering number for the complete unit Remark A7535 Crossarm assembling parts (to be ordered separately) Component Type Qty Remark Single pole assembling parts GFLRME 1 Article number 5821919 H-pole assembling parts GFLRMP 1 Article number 5821920 (pole distance 2000mm c/c) 18 Mast Head installed disconnector 24kV,630A With Hookstick operation, epoxy resin insulators Component Type Qty GP2G 1 GPK 1 Breaking whip GBGK1 1 Phase coupling tube GMA20 1 Crossarm clamps GRF6 3 Operating lever GMK 1 Pole bracket PBRC 1 Operating tube GMR16 1 Assembling crossarm GMA24 1 Telescopical oåperating rod GMR17 1 GHS1 1 - 1 Phase element Hinge Terminal bar Hookstick operating mechanism Resin operating tube Ordering number for the complete unit Ordering number for the complete unit, but with assembled loadbreakhaeds Remark Bolts for pole not included Not supplied by Gevea A8176 A8176/GLBD1 19 Vertical disconnector 24kV,630A With earth blades, epoxy resin insulators Component Type Qty Phase element GP2G 1 Earth blade set EB4 1 Breaking whip GBGK1 1 Phase coupling tube GMA16 2 Crossarm clamps GRF1 3 Operating lever GMK 1 Operating lever GMK5 1 Operating tube GMR2 2 Rod coupling socket GRC 2 Rod guide GSS 4 Operating handle for disconnector GHM 1 GHM2-J 1 Operating handle for earth blade Ordering number for the complete unit excluding assembling crossarm Ordering number for the complete unit including assembling crossarm and pole attacment accessories Remark Include mechanical interlock A8336-1 A8336 20 Masthead installed disconnector 24kV,630A assembled on square concrete pole 200x200mm Ordering No. Description A8099 Complete unit including crossarm and operating mechanism. With assembled breaking whips A8099/LB Complete unit including crossarm and operating mechanism. With assembled loadbreak head 21 Masthead installed disconnector 24kV,630A assembled in steel pole Ordering No. Description A8184/GBGK1 Complete unit including crossarm and operating mechanism. With assembled breaking whips A8184 Complete unit including crossarm and operating mechanism. With assembled loadbreak head 22 Substation installed loadbreakswitch 36kV,630A With earthblades, epoxy resin insulators Component Type Qty Phase element GP2G4 1 Extension part GF2G4 1 Loadbreak head GLBD1 1 Phase coupling tube GMA25 2 Crossarm clamps GRF1 6 Operating lever GMK 1 For disconnector blade Operating lever GMK5 1 For eathblade Operating tube GMR17 2 Operating handle GHM2 1 For disconnector blade Operating handle GHM2-J 1 For earthblade EB4 1 Includes mechanical interlock CPAU 6 Earth blade Connection palm Ordering number for the complete unit Remark A8137 23 AB GEVEA Tlf. +46 11 184800 S-600 12 Norrköping Fax. +46 11 182350 Sweden E -mail. Info@gevea.se www.gevea.se 24 Version 2010-02-10 Eng Box 12043