SAX103 / 103E-1 [225 – 520] MHz Tunable Bandpass Filter Application The SAX103 electronically tunable bandpass filter is designed for Tactical Communications Applications using binary weighted digital tunable capacitor arrays to cover greater than an octave bandwidth. Features • Full Tactical Communications band resolutions • Low insertion loss • High power 4W operation • Fast tuning across band to 1.18 MHz resolution • E-1 version .59 MHz resolution • Convenient 8-bit digital control • E-1 version 9-bit control • Custom designs and specification levels available Specifications Mechanical Dimensions [2.3 x 1.4 x 0.6] inches P0.1dB +36 dBm RF Power Handling Filter Performance Tuning Range Bandpass Bandwidth Insertion Loss @ fc Bandpass VSWR Rejection [225 – 520] MHz fc +/- 2.5 MHz < 3.5 dB [2.7 dB typ] < 2:1 Ftune +/- 10% > 16 dB Ftune +/- 15% > 22 dB Ftune +/- 20% > 27 dB 30 MHz to 0.5*Ftune > 38 dB [2*Ftune to 750] MHz > 35 dB [750 – 1200] MHz > 25 dB [1200 – 2000] MHz > 15 dB Control & Interface Tuning Control 8 bit parallel DC Power +5Vdc @ < 260 mA. [110 mA typ] Tuning Speed = 30 μs Strobe Rate 2 KHz max. [0.5mS max] Strobe Pulse Width 20nS Tuning Algorithm Tune Word= (Ftune -225)/1.18 = (Ftune -225)/0.59 (E1) Ordering Information Version Part Number 1.18 MHz Tuning Step Size/8 bit Digital Control SAX 103 .59 MHz Tuning Step Size/9 bit Digital Control SAX103-E1 Copyright © 2016 NewEdge Signal Solutions, Inc. Information is subject to change without notice. See www.NewEdgeS2.com for latest information. SAX103 Filter Shape Insertion Loss Variation -1 SAX103 Bandpass Insertions per Frequency Word -1.5 Insertion Loss Variation S21(dB) -2 -2.5 -3 -3.5 -4 -4.5 -5 225 275 325 375 425 475 525 Tuned Frequency (MHz) SAX103 Tuning Accuracy Frequency Word NewEdge Signal Solutions | Phoenix Park | 2 Shaker Road, Suite D209 | Shirley, MA 01464 | 978-425-5400 | www.NewEdgeS2.com Copyright © 2016 NewEdge Signal Solutions, Inc. All rights reserved. The information in this document is subject to change without notice. NewEdge Signal Solutions and the NewEdge Signal Solutions logo are registered trademarks of NewEdge Signal Solutions, LLC. SAX103 Insertion Loss vs Frequency SAX103 Switching Speed Information SAX103 Input IP3 Measurements NewEdge Signal Solutions | Phoenix Park | 2 Shaker Road, Suite D209 | Shirley, MA 01464 | 978-425-5400 | www.NewEdgeS2.com Copyright © 2016 NewEdge Signal Solutions, Inc. All rights reserved. The information in this document is subject to change without notice. NewEdge Signal Solutions and the NewEdge Signal Solutions logo are registered trademarks of NewEdge Signal Solutions, LLC. .04 1.10 SAX103-E1 1.40 SN XXX [225-520] MHz TUNABLE 42X .15 PIN 1 2.30 .60 .10 PITCH PIN 1 1.80 42X Ă.02 PIN 21 4X 0-80 UNF-2B .090 MAX .90 2X .64 .38 PIN 22 2X .38 2X 1.54 PIN 42 Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Description RF IN GROUND GROUND Vcc [+5V] GROUND A7 [MSB] A6 A5 A4 A3 A2 A1 A0 STB GROUND GROUND NC GROUND GROUND GROUND RF OUT Disclaimer Specifications are subject to change without notice. NewEdge Signal Solutions, LLC believes the information contained within this data sheet to be accurate and reliable. However, no responsibility is assumed by NewEdge Signal Solutions for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of NewEdge Signal Solutions. NewEdge Signal Solutions makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose. “Typical” parameters are the average values expected by NewEdge Signal Solutions in large quantities and are provided for information purposes only. These values can and do vary in different applications and actual performance can vary over time. All operating parameters should be validated by customer’s technical experts for each application. NewEdge Signal Solutions products are not designed, intended or authorized for use as components in applications intended for surgical implant into the body or to support or sustain life, in applications in which the failure of the NewEdge Signal Solutions product could result in personal injury or death or in applications for planning, construction, maintenance or direct operation of a nuclear facility. All product sales are governed under NewEdge Signal Solutions Terms and Conditions (http://www.newedges2.com/TermsandConditions.pdf ) as of date of purchase. Authorized Distributors Richardson RFPD Email: rfpdsales@richardsonrfpd.com Phone: 630-262-6800 Fax: 630-262-6850 Toll Free: 800-737-6937 NewEdge Signal Solutions | Phoenix Park | 2 Shaker Road, Suite D209 | Shirley, MA 01464 | 978-425-5400 | www.NewEdgeS2.com Copyright © 2016 NewEdge Signal Solutions, Inc. All rights reserved. The information in this document is subject to change without notice. NewEdge Signal Solutions and the NewEdge Signal Solutions logo are registered trademarks of NewEdge Signal Solutions, LLC.