Description
Hazardous location lighting fixtures designed for use in conjunction with 700 Series emergency units or
as stand alone fixtures in extreme environments. HR Series fixtures may be connected to or operated
remotely from 700 Series emergency units. HR Series fixtures may also be remotely powered from AC
or DC power sources located outside the hazardous location.
HR Series fixtures are suitable for use in NEC Class I, Division 1, Groups C&D, Zones 0, 1 & 2, Groups
IIA, IIB+H2 & IIC; Class I, Division 2, Groups C&D, Zone 2, Groups IIA, IIB+H2 & IIC; Class II, Division 1,
Groups EF&G; Class II, Division 2, Groups F&G and Class III hazardous locations.
Construction
Housing: Heavy duty, copper-free cast aluminum housing designed and constructed to withstand the
pressure of explosions caused by an internal arc without propagating them into the hazardous atmosphere. Housings have a corrosion resistant, epoxy powder coat finish. All HR Series fixtures include a
high impact, heat resistant globe with a cast aluminum globe guard and stainless steel hardware.
Installation
Wiring: Ceiling and wall mount fixtures provide a universal junction box with four threaded openings
for the attachment of 3/4” rigid conduit. Three close-up plugs are provided. Pendant mount fixtures
provide a threaded 3/4” top hub.
Maximum ambient temperature limit is 320ºF (160ºC).
Illumination
Available with low voltage halogen lamps and 7-watt compact fluorescent lamps if emergency power is
provided by a model 714 unit.
HR Series fixtures are compatible with medium base incandescent or 13 watt compact fluorescent
lamps for non-emergency lighting applications.
Description
Heavy duty, copper free cast aluminum construction with a corrosion resistant, epoxy powder coat finish. Head assembly is fully
adjustable. EVLA12 heads meet NEC Class I, Division 1 & 2,
Groups B+, C & D; Class II, Division 1, Groups E, F & G; Class III;
NEMA 3, 3R & 12 hazardous location requirements.
Installation
Wiring: Designed for direct or remote attachment to 750 Series
emergency units or operation remotely from a 12VDC emergency
source located in a non-hazardous area.
Maximum ambient temperature limit is 131ºF (55ºC).
Illumination
Supplied with 12V, 12W MR16 Halogen lamp.
HRC Series
(Ceiling)
HRW Series
(Wall)
HRP Series
(Pendant)
Catalog Numbers:
ELVA12 - 12V, 12W Head
ELVA12GB - 12V, 12W Head
Group B Operation
DIMENSIONS
EVLA12 Directional Head
9”
45/8”
11.7cm
22.9cm
9”
22.9cm
ORDERING INFORMATION
HR Wall Mount
111/8”
HR Ceiling Mount
26.1cm
Catalog Number: Example: HRW120P13
HR
SERIES
143/8”
143/8”
MOUNTING
C - Ceiling
W - Wall
P - Pendant
EXK Exit Kit
HR-Series Fixture shown with
EXK 3-face exit kit installed.
To order, add EXK suffix to
model number.
Ex.: HRCTHF12EXK
INPUT VOLTAGE
Incandescent
Blank - 120VAC
Fluorescent
120 - 120VAC
277 - 277VAC
AC-Only Use(1)
HF - 150W-A19
Incandescent
P13 - 13W CFL
P26 - Two 13W CFL
Emergency Use (2)
HF7 - 6V, 7W Hal.
HF10 - 6V, 10W Hal.
HF12 - 6V, 12W Hal.
THF12 - 12V, 12W
Hal.
HFP7- 7W CFL (3)
(1)Lamps not provided
with fixture.
(2)Lamps provided with
fixture.
(3)For use with 714
emergency unit only.
Maximum mounting
distance from 714 unit
is 8 feet
Specifications are subject to change without notice. Consult website for latest version of this spec sheet.
Crescent/Stonco • 200 Franklin Square Drive • Somerset, NJ 08873 • 800-334-2212 • www.crescentlighting.com
Crescent is a Philips company
36.2cm
36.2cm
LAMP ID
73/8”
18.5cm
73/8”
18.5cm
EXK Exit Kit
HR Pendant Mount
147/8”
38.8cm
73/8”
18.5cm
173/4”
45.2cm
12”
30.5cm
NOTE: Dimensions and specifications subject to change without notice.
Form 1274A 04/12 © 2006 Philips group
Download