Installation and Operating Instructions Bulletin 56RF High Temperature ICODE Tag (High Frequency RFID 13.56 MHz) IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. Description Specifications Industrial RFID systems are designed to withstand harsh environments. Reusable read/write tags allow for flexibility in information and application. ISO 15693 is an open standard for high frequency 13.56 MHz RFID. ICODE tags are available in many different styles and sizes to fit most applications. 56RF-TG-50HT high temperature RFID tag is IP68 rated and designed to withstand harsh environments. It is specifically designed for industrial applications where temperatures can go as high as 240°C (464°F). It is suited for automotive assembly lines and paint shop applications, and provides reliable data retention. Description Parameter Chip type ICode SL2 Resonance frequency (SRF) 13.8 MHz ± 0.4 MHz Operating temperature [C (F)] -25…85° (-13…185°) Storage temperature [C (F)] -55…185° (-67…365°) (cumulative time more than 1500 h) Peak temperature [C (F)] 200° (392°)/60 min 220° (428°)/45 min 240° (464°)/30 min Chemical resistance Acetone 5% Sodium carbonate 5% Salt water 5% Sugar water 5% Acetic acid 60% Ethyl alcohol Features • 13.56 MHz high frequency RFID solution • ICODE ISO 15693 Compliant • 128 byte memory Housing material PPS plastics • Read/write speed up to 500 bytes per second Color Black • Reusable tags Size [mm (in.)] 51.0 x 51.0 ± 0.5 (2.01 x 2.01 ± 0.02) • Reliable performance in harsh environment Thickness [mm (in.)] 6.5 ± 0.5 (0.26 ± 0.02) • IP68 Hole diameter [mm (in.)] 5.5 ±0.5 (0.217 ±0.02) Counterbore 10.5 (0.413) • High temperature up to 240°C (464°F) - 200°C (392°F) 60 minutes Weight [g (oz)] 30 (1.06) typical - 220°C (428°F) 45 minutes Protection category IP68 - 240°C (464°F) 30 minutes Tightening Torque 2 Nm max. (use M5 screw with a flat head and mount on a nonmetal plain base) Mechanical resistance Vibration IEC 68.2.6, shock IEC 68.2.29 Typical applications • High temperature industrial • Automotive Dimensions [mm (in.)] • Paint shop • Asset tracking 51 ±0.5 (2.008 ±0.02) • Product handling 6.5 (0.256) Ø 10.5 (Ø 0.413) • Tool management 51 ±0.5 (2.008 ±0.02) Ø 5.5 (Ø 0.217) Temperature test profile Time at elevated temperature The 56RF-TG-50HT high temperature tags were tested according to the following profile: The length of time the tags can withstand elevated temperature depends on the temperature (see table and graph below). 1. Tested at 60°C (140°F) 2. Placed in an oven at 185°C (365°F) for 30 minutes and then 240°C (464°F) for 30 minutes 3. Removed from oven and tested at 60°C (140°F) The cycle was repeated after 20 minutes. Temperature [°C (°F)] Temperature x [C (F)] Time y minutes 200° (392°) 60 220° (428°) 45 240° (464°) 30 Non-operating x 185° (365°) Operating (Read/write) 60° (140°) 3 30 y 3 4 20 Time (minutes) www.rockwel lautomation.com Power, Control and Information Solutions Headquarters Americas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444 Europe/Middle East/Africa: Rockwell Automation NV, Pegasus Park, De Kleetlaan 12a, 1831 Diegem, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640 Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846 56RF-IN011B-EN-P September 2014 Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.