MOTOR CONTROLS
HUMIDITY
MOTOR
CONTROLS
Kele Has Soft Starters and VFDs to Extend the Life of Your Motor
and Help Save Energy and Maintenance Costs.
Core VFD Series | p. 695
PSR Series | p. 681
FCXLS/NFCXLS | p. 692
MOTOR CONTROLS
Products manufactured
in the United States
Products that are
new to the catalog
MODEL/SERIESPAGE
Motor Disconnects
ABB EOT Series — Enclosed Non-Fused Disconnect Switch. . . . . . . . . . . . . 689
BCXLS Series — Breaker Combination Motor Starters. . . . . . . . . . . . . . . . . . 690
FCXLS, NFCXLS Series — Fusible and Non-Fusible Motor Starters . . . . . . . 692
Motor Starters
PSR Series — Softstarters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681
A Series — ABB 3 Phase Motor Starter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683
TEC Compact Starters — 3 Phase Motor Starters. . . . . . . . . . . . . . . . . . . . . 687
MOTOR
CONTROLS
A Series | p. 683
TEC Compact | p. 687
Starters
Smart VFD | p. 704
HVAC
kele.com
Variable Frequency Drives (VFD) and Bypasses
CORE VFD — Honeywell Variable Frequency Drives. . . . . . . . . . . . . . . . . . . .
CORE VFD With Bypass — Honeywell Variable Frequency Drives. . . . . . . . .
SmartDrive Compact VFD — Honeywell Compact Variable Frequency
Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SMARTVFD HVAC — Honeywell All Purpose Variable Frequency Drives. . . .
SMARTVFD HVAC With Bypass Assembly — Variable Frequency Drives
with Bypass. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
695
698
702
704
707
NEW!
MOTOR CONTROLS
SOFTSTARTERS
PSR SERIES
DESCRIPTION
Constant-speed AC motors are used to drive HVAC fans and
pumps. During start and stop, both mechanical and electrical
stresses are high, causing undesirable load peaks each time
the motors are started. An ABB Softstarter eliminates many
of these problems. The voltage is smoothly applied to, and
removed from, the motor. Both the torque and the current
consequently behave in the same way. The result is that
mechanical and electrical stresses are significantly lower than
with conventional starting methods.
The PSR series Compact Softstarters range covers motor
currents from 3 to 46A. All sizes include a Run signal relay.
The 25A and above are also provided with an output signal
for TOR (Top Of Ramp, i.e. full voltage). With standard
performance the PSR Softstarters handle ten starts per hour.
When an auxiliary cooling fan is added, the starting capacity
is increased to 20 starts per hour.
FEATURES
PSR16-600-70
•
•
•
•
• Compact size
• Easy to install and adjust
• DIN rail or screw mounting
PSR30-600-70
PSR45-600-70
Run signal relay
25A and above includes "Top Of Ramp" output signal
Motor ratings up to 600 VAC and 40Hp
Seperate Acceleration/ Deceleration times
SPECIFICATIONS
100/ 240 V, 24 VDC
208 to 600 VAC
3.9A Starting capacity 15.6A for 6s
6.8A Starting capacity 27.2A for 6s
9A Starting capacity 36A for 6s
12A Starting capacity 48A for 6s
16A Starting capacity 64A for 6s
25A Starting capacity 100A for 6s
30A Starting capacity 120A for 6s
37A Starting capacity 148A for 6s
46A Starting capacity 180A for 6s
Based on rated Voltage and FLA
Acceleration Time
Deceleration Time
Altitude Limits
Protection Rating
LED Indication
1-10 seconds
0-20 seconds
13,123 ft. (4000 m)
Main circuit IP20 Control Circuit IP20
On/ Ready Green On/ Ready Green
Run/ Top of Ramp Green
Run/ Top of Ramp Green
Operating Temperature-13° to 140°F (-25° to 60°C)
Storage Temperature -40° to 158°F (-40° to 70°C)
Number of Starts/ hr 10 standard; 20 with Aux. Fan
Approvals
UL ListedFile E161428
Warranty
12 months from installation,
maximum 18 months from factory
WIRING
Fuse
(customer
supplied)
Circuit
protection
by customer
Circuit
protection
by customer
PSR
Fuse
(customer
supplied)
PSR
Note: verify motor nameplate
voltage and horsepower
rating for soft starter selection
Note: verify motor nameplate
voltage and horsepower
rating for soft starter selection
March 2014
N/C
COM
L/+
N/C
Supply Voltage
Model PSR25 - 45 with MCCB
COM
L/+
Supply
Voltage
Model PSR3 - 16 with MCCB
12
MOTOR CONTROLS
Supply Voltage
Motor Voltage Rating
Current Rating
PSR3
PSR6
PSR9
PSR12
PSR16
PSR25
PSR30
PSR37
PSR45
Horsepower
WE MAKE IT EASY.
kele.com
888-397-5353 USA
681
NEW!
MOTOR CONTROLS
SOFTSTARTERS
PSR SERIES
ORDERING INFORMATION
MOTOR CONTROLS
12
Model
Control
Supply
Voltage
Full
Circuit
Horsepower
Load
Breaker Fuse Size
Amps 208V 240V 480V 600V Max.
PSR3-600-70
100/ 240 V
3.4
.5
0.75
2
2
PSR6-600-70
100/ 240 V
6.1
1
1.5
3
PSR9-600-70
100/ 240 V
9
2
2
PSR12-600-70
100/ 240 V
11
3
PSR16-600-70
100/ 240 V
15.2
PSR25-600-70
100/ 240 V
PSR30-600-70
Dimensions
Weight
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
0.99 lbs.
(0.45 kg)
5
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
0.99 lbs.
(0.45 kg)
5
7.5
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
0.99 lbs.
(0.45 kg)
3
7.5
10
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
0.99 lbs.
(0.45 kg)
3
3
10
10
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
0.99 lbs.
(0.45 kg)
24.2
7.5
7.5
15
20
50 A
40 A J-Type
6.30" x 1.77" x 5.04"
(160mm x 45mm x 128mm)
1.43 lbs.
(0.65 kg)
100/ 240 V
28
7.5
7.5
20
25
50 A
40 A J-Type
6.30" x 1.77" x 5.04"
(160mm x 45mm x 128mm)
1.43 lbs.
(0.65 kg)
PSR37-600-70
100/ 240 V
34
10
10
25
30
50 A
40 A J-Type
7.36" x 1.77" x 6.02"
(187mm x 45mm x 153mm)
2.20 lbs.
(1.00 kg)
PSR45-600-70
100/ 240 V
46.2
15
15
30
40
50 A
40 A J-Type
7.36" x 1.77" x 6.02"
(187mm x 45mm x 153mm)
2.20 lbs.
(1.00 kg)
PSR3-600-81
24 VDC
3.4
.5
.5
2
2
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
2.20 lbs.
(1.00 kg)
PSR6-600-81
24 VDC
6.1
1
1
3
5
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
0.99 lbs.
(0.45 kg)
PSR9-600-81
24 VDC
9
2
2
5
7.5
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
0.99 lbs.
(0.45 kg)
PSR12-600-81
24 VDC
11
3
3
7.5
10
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
0.99 lbs.
(0.45 kg)
PSR16-600-81
24 VDC
15.2
3
3
10
10
50 A
40 A J-Type
5.51" x 1.77" x 4.47"
(140mm x 45mm x 113.5mm)
0.99 lbs.
(0.45 kg)
PSR25-600-81
24 VDC
24.2
7.5
7.5
15
20
100 A
60 A J- Type
6.30" x 1.77" x 5.04"
(160mm x 45mm x 128mm)
1.43 lbs.
(0.65 kg)
PSR30-600-81
24 VDC
28
7.5
10
20
25
100 A
70 A J- Type
6.30" x 1.77" x 5.04"
(160mm x 45mm x 128mm)
1.43 lbs.
(0.65 kg)
PSR37-600-81
24 VDC
34
10
10
25
30
150 A
100 A J- Type
7.36" x 1.77" x 6.02"
(187mm x 45mm x 153mm)
2.20 lbs.
(1.00 kg)
PSR45-600-81
24 VDC
46.2
15
15
30
40
150 A
100 A J- Type
7.36" x 1.77" x 6.02"
(187mm x 45mm x 153mm)
2.20 lbs.
(1.00 kg)
PSR-FAN
682
888-397-5353 USA
ACCESSORIES
Cooling Fan for increased starting capacity (field-installable)
kele.com
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
ABB 3 PHASE MOTOR STARTER
A SERIES
DESCRIPTION
The A Series ABB starter line offers motor start/stop and
protection. The double-break contacts allow stopping a motor
with minimal conact wear. The thermal overloads are sized
for the motor FLA and keep motor windings from over-heating
during overload conditions. We offer these starters in open,
enclosed, enclosed with fusible disconnect, and enclosed
with circuit breaker. Auxiliary contacts are available for field
installation.
FEATURES
•
•
•
•
•
•
•
NEMA sizes 00 thru 5
UL508A panel program, file #E105450
Compact space-saving design
Auxiliary contacts available
Coil operates 85 to 110% of rated voltage
Solid-state adjustable overload relays standard
Conventional bimetallic overloads available
A50NSF1-84A6B
A9NS1-81E
DIMENSIONS
12
Enclosed Starters in (cm)
MODEL SIZE
A9, A16, A26
A50, A75
A260
NEMA 1 fused
14"H x 12"W x 8"D
(35.6 x 30.5 x 20.3 cm)
20"H x 16"W x 8"D
(50.8 x 40.6 x 20.3 cm)
30"H x 24"W x 12"D
(76.2 x 61.0 x 30.5 cm)
36"H x 30"W x 12"D
(91.4 x 76.2 x 30.5 cm)
NEMA 1 circuit breaker
14"H x 12"W x 8"D
(35.6 x 30.5 x 20.3 cm)
14"H x 12"W x 8"D
(35.6 x 30.5 x 20.3cm)
24"H x 20"W x 8"D
(61.0 x 50.8 x 20.3 cm)
30"H x 24"W x 12"D
(76.2 x 61.0 x 30.5 cm)
Open Frame Starters in (cm)
MODEL SIZE
A9, A16
A26
A50, A75
A145
A260
March 2014
5.3"H x 1.7"W x 3.7"D
(13.3 x 4.4 x 9.5 cm)
5.8"H x 2.1"W x 4.3"D
(9.0 x 2.1 x 11.0 cm)
6.9"H x 2.8"W x 4.4"D
(17.7 x 7.0 x 11.3 cm)
12.9"H x 4.1"W x 6.3"D
(32.9 x 10.5 x 16.0 cm)
17.5"H x 5.5"W x 7.1"D
(44.4 x 14 x 18.1 cm)
WE MAKE IT EASY.
kele.com
888-397-5353 USA
MOTOR CONTROLS
A145
NEMA 1
11"H x 6"W x 5"D
(27.9 x 15.2 x 12.7 cm)
13"H x 9"W x 7"D
(33.0 x 22.9 x 17.8 cm)
30"H x 24"W x 12"D
(76.2 x 61.0 x 30.5 cm)
30"H x 24"W x 12"D
(76.2 x 61.0 x 30.5 cm)
683
NEW!
MOTOR CONTROLS
ABB 3 PHASE MOTOR STARTER
A SERIES
WIRING
Non-reversing, reversing
AF09 - AF750, AFN00 - AFN4
L1
Incoming Lines
L1 L2 L3
Disconnect
1
3
5
2
4
6
Fuse
Disconnect
3
1
External Control
Supply Standard 120 VAC
Breaker
CX2
CX1
5
2-1 1-1
X1
X2
2
L1
M
T1
1-2 2-2
L2
L3
T2
T3
4
6
OL
97
OL
95
3-1
98
96
3-7
3-2 3-2
3-6
JUMPER
OL
T1
3-3
14
M A2
15
3-4 3-4
T3
T2
1
12
A1
OL
2
*
MOTOR
Disconnect
MOTOR CONTROLS
Incoming Lines
L1 L2 L3
Remote Contact
Customer
1
3
5
2
4
6
Fuse
Disconnect
1
3
Breaker
5
External Control
Supply Standard 120 VAC
CX1
2
4
CX2
6
2-1 1-1
1-2 2-2
3-7
X2
X1
L1
L2
L3
L1
L2
3-6
L3
R
T2
T3
T1
T2
F
3-2 3-2
JUMPER
F
T1
R
T3
14
3-5
01
21
13
R
3-3
14
01
21
F
01
22
A1
F A2
01
22
A1
R A2
13
3-4 3-4
OL
T1
T2
T3
3
1
2
4
*
F
MOTOR
*
R
All units ship with a NO and NC contacts.
Additional contacts can be added in the field.
684
888-397-5353 USA
kele.com
Remote Contact
Customer
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
ABB 3 PHASE MOTOR STARTER
A SERIES
WIRING
2 speed, 1 winding; 2 speed, 2 winding
AF09 - AF75
Disconnect
Incoming Lines
L1 L2 L3
1
3
5
2
4
6
Fuse
Disconnect
1
3
5
2
4
6
Breaker
External Control
Supply Standard 120VAC
CX1
CX2
2-1 1-1
1-2 2-2
3-7
SOL FOL
X2
L1
L3
L1
X1
L2
L3
T2
T3
T1
T2
T3
S
T1
95
96
95
96
3-6
3-2 3-2
F
S
3-9
14
3-5
Jumper
L2
F
01
21
13
F
3-3
14
01
22
A1
01
22
A1
S
01
21
S A2
F
A2
13
3-4 3-4
FOL
SOL
T1
T2
T3
T1
T2
3
T2
*
12
T3
1
2
4
*
S
T13
T12
T1 MOTOR T11
*
F
Disconnect
3
5
2
4
6
1
3
Remote Contact
Customer
Breaker
External Control
Supply Standard 120VAC
5
CX1
2
4
MOTOR CONTROLS
1
Fuse
Disconnect
CX2
6
1-2 2-2
2-1 1-1
SOL FOL
95
96
95
96
3-7
3-2 3-2
1F
3-6
S
Jumper
3-9
3-5
14
01
21
13
2F
3-3
14
S
01
21
13
1
01
22
21
22
A1
13
A1
1F
14
S A2
2F
A2
1F A2
A1
3-4 3-4
3
01
22
2F
2
4
*
S
All units ship with a NO and NC contacts.
Additional contacts can be added in the field.
March 2014
*
F
Remote Contact
Customer
WE MAKE IT EASY.
kele.com
888-397-5353 USA
685
NEW!
MOTOR CONTROLS
ABB 3 PHASE MOTOR STARTER
A SERIES
WIRING
Non-reversing, single phase
AF09 - AF110, AFN00 - AFN2
L1
Incoming Lines
L1 L2
X1
Disconnect
1
3
5
2
4
6
Fuse
Disconnect
1
3
External Control
Supply Standard 120 VAC
Breaker
2-1 1-1
OL
X2
97
2
L1
T1
4
6
L3
T2
3-1
98
OL
95
96
1-2 2-2
3-7
3-2 3-2
3-6
JUMPER
M
L2
CX2
CX1
5
T3
A1
OL
3-3
14
M A2
15
3-4 3-4
OL
T1
T2
1
T3
2
*
All units ship with a NO and NC contacts.
Additional contacts can be added in the field.
MOTOR
12
Remote Contact
Customer
ORDERING INFORMATION
MOTOR CONTROLS
NEMA
SIZE
00
0
1
2
3
4
5
MOTOR HORSEPOWER
3-PHASE, 1800 RPM**
200V
230V
460V
–
–
1/4
–
1/4
1/3, 1/2
–
1/3
3/4
1/3, 1/4
1/2
1
1/2
–
–
3/4
3/4
1.5, 2
–
1
–
1
1.5
–
1.5
–
–
–
–
3
2
2
5
3
3
–
–
–
7.5
5
5
10
7.5
7.5
–
–
–
15
–
10
20
10
15
25
–
–
–
15
–
30
20
20
40
25
25, 30
50
–
–
–
–
–
60
30
40
75
40
50
100
50
–
–
60
60
125
–
100
200
575V
1/2
–
3/4
1
1.5, 2
–
–
–
–
5
–
–
10
–
–
20
25
–
30
40
50
–
60
75
100
–
125
150
–
OVERLOAD
RELAY
MODEL
SETTING
OPEN STYLE
RANGE
A9N00S-*E
0.63 - 1.0
A9N00S-*F
1.0 - 1.4
A9N00S-*G
1.3 - 1.6
A9N00S-*H
1.7 - 2.4
A9N00S-*J
2.2 - 3.1
A9N00S-*K
2.8 - 4.0
A9N00S-*L
3.5 - 5.0
A9N00S-*M
4.5 - 6.5
A9N00S-*N
6.0 - 8.5
A16N0S-*M
4.5 - 6.5
A16N0S-*N
6.0 - 8.5
A16N0S-*P
7.5 - 11
A26N1S-*Q
10 - 14
A26N1S-*R
13 - 19
A26N1S-*S
18 - 25
A50N2S-*A
18 - 25
A50N2S-*B
22 - 32
A50N2S-*C
29 - 42
A75N3S-*C
29 - 42
A75N3S-*D
36 - 52
A75N3S-*E
45 - 63
A75N3S-*F
60 - 80
A145N4S-*R
65 - 90
A145N4S-*A
65 - 90
A145N4S-*B
65 - 90
A145N4S-*C
65 - 90
A260N5S-*T
110 - 150
A260N5S-*A
130 - 185
A260N5S-*C
220 - 310
MODEL
NEMA 1
ENCLOSED
A9NS1-*E
A9NS1-*F
A9NS1-*G
A9NS1-*H
A9NS1-*J
A9NS1-*K
A9NS1-*L
A9NS1-*M
A9NS1-*N
A16NS1-*M
A16NS1-*N
A16NS1-*P
A26NS1-*Q
A26NS1-*R
A26NS1-*S
A50NS1-*A
A50NS1-*B
A50NS1-*C
A75NS1-*C
A75NS1-*D
A75NS1-*E
A75NS1-*F
A145NS1-*R
A145NS1-*A
A145NS1-*B
A145NS1-*C
A260NS1-*T
A260NS1-*A
A260NS1-*C
MODEL
NEMA 1
ENCL.
FUSIBLE
DISCONNECT
A9NSF1-*E6A
A9NSF1-*F6A
A9NSF1-*G6A
A9NSF1-*H6A
A9NSF1-*J6A
A9NSF1-*K6A
A9NSF1-*L6A
A9NSF1-*M6A
A9NSF1-*N6A
A16NSF1-*M6A
A16NSF1-*N6A
A16NSF1-*P6A
A26NSF1-*Q6A
A26NSF1-*R6A
A26NSF1-*S6A
A50NSF1-*A6B
A50NSF1-*B6B
A50NSF1-*C6B
A75NSF1-*C6C
A75NSF1-*D6C
A75NSF1-*E6C
A75NSF1-*F6C
A145NSF1-*R6E
A145NSF1-*A6E
A145NSF1-*B6E
A145NSF1-*C6E
A260NSF1-*T6E
A260NSF1-*A6E
A260NSF1-*C6E
FUSE
CLIP
SIZE
CLASS
J
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
30A
60A
60A
60A
100A
100A
100A
100A
400A
400A
400A
400A
400A
400A
400A
MODEL
NEMA 1
ENCL.
W/CIRCUIT
BREAKER
A9NSM1-*E4A
A9NSM1-*F4A
A9NSM1-*G4A
A9NSM1-*H4A
A9NSM1-*J4B
A9NSM1-*K4B
A9NSM1-*L4C
A9NSM1-*M4C
A9NSM1-*N4C
A16NSM1-*M4C
A16NSM1-*N4C
A16NSM1-*P4D
A26NSM1-*Q4D
A26NSM1-*R4D
A26NSM1-*S4E
A50NSM1-*A4E
A50NSM1-*B4E
A50NSM1-*C4E
A75NSM1-*C4E
A75NSM1-*D4F
A75NSM1-*E4F
A75NSM1-*F4F
A145NSM1-*R4F
A145NSM1-*A4F
A145NSM1-*B4F
A145NSM1-*C4F
A260NSM1-*T4H
A260NSM1-*A4H
A260NSM1-*C4J
CIRCUIT
BREAKER
RATING
(480 V MAX)
3
3
3
3
5
5
10
10
10
10
10
25
25
25
50
50
50
50
50
100
100
100
100
100
100
100
250
250
400
*Insert code 84 for 120 VAC 60Hz, code 80 for 240 VAC, code 81 for 24 VAC 50/60 Hz
**Check full load amp rating on motor nameplate to ensure proper overload protection
Note - for additional auxiliary contacts add suffix 10 for 1 N.O., 20 for 2 N.O., 01 for 1 N.C., 02 for 2 N.C., 11 for 1 N.O. & 1 N.C.
Example: A50N2S-84A-20 Open frame style, 10 HP, 120 VAC coil, 2 N.O. auxiliary contacts
686
888-397-5353 USA
kele.com
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
3 PHASE MOTOR STARTERS
TEC COMPACT STARTERS
DESCRIPTION
TEC Compact Starters are compact 3 phase motor starters.
They have an enameled copper wire coil and have fingersafe contacts.These starters are UL 508SB rated. There is an
external window indicator that shows contact wear.
FEATURES
•
•
•
•
•
•
Compact design
cULus, CE, and UL508 approved
Available with reset or start stop
NEMA 4X enclosed
Single or three phase
Class 10 overloads
TEC18-AKSS3-18A
SPECIFICATIONS
HORSE POWER - 3PHASE
Part Number
TEC12-A4XR-8A
200V
2
230V
2.5
480V
5
600V
7.5
Coil
Voltage
120V
Enclosure
NEMA Rating
4X
Control Type/
Version
Reset only
Overload Amp Weight
Range
lbs (kg)
5.5 - 8A
2.3 (1.04)
TEC12-G4XR-8A
2
2.5
5
7.5
24V
4X
Reset only
5.5 - 8A
2.3 (1.04)
TEC12-AKSS3-8A
2
2.5
5
7.5
120V
4X
Start/stop
5.5 - 8A
2.3 (1.04)
TEC12-GKSS3-8A
2
2.5
5
7.5
24V
4X
Start/stop
5.5 - 8A
2.3 (1.04)
TEC12-A4XR-13A
3
3
7.5
10
120V
4X
Reset only
9 - 13A
2.3 (1.04)
TEC12-G4XR-13A
3
3
7.5
10
24V
4X
Reset only
9 - 13A
2.3 (1.04)
TEC12-AKSS3-13A
3
3
7.5
10
120V
4X
Start/stop
9 - 13A
2.3 (1.04)
TEC12-GKSS3-13A
3
3
7.5
10
24V
4X
Start/stop
9 - 13A
2.3 (1.04)
TEC18-A4XR-18A
5
5
10
15
120V
4X
Reset only
7 - 10A
2.3 (1.04)
5
5
10
15
24V
4X
Reset only
7 - 10A
2.3 (1.04)
5
5
10
15
120V
4X
Start/stop
7 - 10A
2.3 (1.04)
TEC18-GKSS3-18A
5
5
10
15
24V
4X
Start/stop
7 - 10A
2.3 (1.04)
TEC25-A4XR-25A
5
7.5
15
20
120V
4X
Reset only
17- 25A
2.7 (1.22)
TEC25-G4XR-25A
5
7.5
15
20
24V
4X
Reset only
17- 25A
2.7 (1.22)
TEC25-AKSS3-25A
5
7.5
15
20
120V
4X
Start/stop
17- 25A
2.7 (1.22)
TEC25-GKSS3-25A
5
7.5
15
20
24V
4X
Start/stop
17- 25A
2.7 (1.22)
Other options and models available from manufacturer.
DIMENSIONS
A
B
C
D
E
TEC12, TEC18 Starters
4.72" (11.98 cm)
5.51" (18.99 cm)
6.54" (16.61 cm)
5.9" (14.98 cm)
3.46" (8.78 cm)
TEC25 Starter
5.31" (13.48 cm)
6.1" (15.49 cm)
7.28" (18.49 cm)
6.5" (16.51 cm)
3.98" (10.10 cm)
E
B
March 2014
D
C
A
WE MAKE IT EASY.
MOTOR CONTROLS
TEC18-G4XR-18A
TEC18-AKSS3-18A
12
kele.com
888-397-5353 USA
687
NEW!
MOTOR CONTROLS
3 PHASE MOTOR STARTERS
TEC COMPACT STARTERS
WIRING
STOP
L1(X1)
13
M
A1
14
(A)
M
A2
(B)
START
95
96
OL RESET
17 18
START-STOP PUSHBUTTONS Series TEC…KSS3…*
STOP
L1(X1)
13
M
14
A1
(A)
START
M
A2
(B)
95
L2(X2)
L2
L1
L1
L3
L1
L2
L1
L2
L2
M
M
13
14
Aux. NO
L2(X2)
96
OL
T1
OL RESET
17 18
REMOTE START-STOP PUSHBUTTONS Series TEC…4XR… (Reset only)*
* L2 on control circuit should be connected to neutral for 120V control voltage.
Dashed lines indicate field connection.
T2
T3
OL
T1
T2
MTR
MTR
THREE-PHASE*
SINGLE-PHASE*
ORDERING INFORMATION
MOTOR CONTROLS
12
MODEL
TEC12-A4XR-8A
TEC12-G4XR-8A TEC12-AKSS3-8A TEC12-GKSS3-8A TEC12-A4XR-13A TEC12-G4XR-13A TEC12-AKSS3-13A TEC12-GKSS3-13A TEC18-A4XR-18A TEC18-G4XR-18A TEC18-AKSS3-18A TEC18-GKSS3-18A
TEC25-A4XR-25A
TEC25-G4XR-25A TEC25-AKSS3-25A
TEC25-GKSS3-25A
DESCRIPTION
Compact starter, 3 phase, 120 VAC, with reset and overload,5.5 to 8 Amps
Compact starter, 3 phase, 24 VAC, with reset and overload, 5.5 to 8 Amps
Compact starter, 3 phase, 120 VAC, start/stop and overload, 5.5 to 8 Amps
Compact starter, 3 phase, 24 VAC, start/stop and overload, 5.5 to 8 Amps
Compact starter, 3 phase, 120 VAC, with reset and overload, 9 to 13 Amps
Compact starter, 3 phase, 24 VAC, with reset and overload, 9 to 13 Amps
Compact starter, 3 phase, 120 VAC, start/stop and overload, 9 to 13 Amps
Compact starter, 3 phase, 24 VAC, start/stop and overload, 9 to 13 Amps
Compact starter, 3 phase, 120 VAC, with reset and overload, 12 to 18 Amps
Compact starter, 3 phase, 24 VAC, with reset and overload, 12 to 18 Amps
Compact starter, 3 phase, 120 VAC, start/stop and overload, 12 to 18 Amps
Compact starter, 3 phase, 24 VAC, start/stop and overload, 12 to 18 Amps
Compact starter, 3 phase, 120 VAC, with reset and overload, 17 to 25 Amps
Compact starter, 3 phase, 24 VAC, with reset and overload, 17 to 25 Amps
Compact starter, 3 phase, 120 VAC, start/stop and overload, 17 to 25 Amps
Compact starter, 3 phase, 24 VAC, start/stop and overload, 17 to 25 Amps
ACCESSORIES
EEC0.63-1A
Overload relay TEC Series/0.63-1 Amps
EEC1-1.6A
Overload relay TEC Series/1-1.6 Amps
EEC1.6-2.5A
Overload relay TEC Series/1.6-2.5 Amps
EEC2.5-4A
Overload relay TEC Series/2.5-4 Amps
EEC4-6A
Overload relay TEC Series/4-6 Amps
EEC5.5-8A
Overload relay TEC Series/5.5-8 Amps
EEC7-10A
Overload relay TEC Series/7-10 Amps
EEC9-13A
Overload relay TEC Series/9-13 Amps
EEC12-18A
Overload relay TEC Series/12-18 Amps
EEC17-25A
Overload relay TEC Series/17-25 Amps
688
888-397-5353 USA
kele.com
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
ENCLOSED NON-FUSED DISCONNECT SWITCH
ABB EOT SERIES
DESCRIPTION
The EOT Series of enclosed manual motor controllers are
rotary operated, 3 pole, 600V Hp rated switches, housed in
thermoplastic/polycarbonate enclosures suitable for wet and
corrosive environments. These NEMA 3R/12 models are
equipped with selector style handles. They are compact in size
have touch safe operation. cUL/IEC-47-3 approvals and UL508
listed.
FEATURES
•
•
•
•
•
•
•
•
Suitable as motor disconnect
Horsepower rated
Touch safe construction
Positive operation
Clear position indication
Self lifting tunnel terminals
Extremely compact size
Accessories include 4th Power Pole & Snap-on auxiliary
contacts
• OSHA Lock Out/Tag Out
Selector switch style
WIRING
SPECIFICATIONS
Supply Voltage
600V MAX
Enclosure Rating
NEMA 3R/12
Auxiliary Contacts (optional)
Maximum number allowed: 2NO +
1NC
Meets ARRA or BAA
Yes
Dimensions, Including Handle
EOT16 & EOT32
6.36"H x 3.94"W x 4.55"D
(16.2 x 10 x 11.6 cm)
EOT45
7.87"H x 5.75"W x 5.43"D
(19.8 x 14.6 x 18.8 cm)
EOT63
11.81"H x 8.27"W x 7.12"D
(30 x 21 x 181 cm)
Approvals
UL Listed E63822, IEC947-3, UL 508
Note: Only 1 additional pole per switch allowed
MODEL
EOT16U3P3-S
EOT16U3P3-1S
EOT16U3P3-S1
EOT16U3P3-1S1
EOT32U3P3-S
EOT32U3P3-1S
EOT32U3P3-S1
EOT32U3P3-1S1
EOT45U3P3-S
EOT45U3P3-1S
EOT45U3P3-S1
EOT45U3P3-1S1
EOT63U3P3-P
EOT63U3P3-1P
EOT63U3P3-P1
EOT63U3P3-1P1
March 2014
DESCRIPTION
Black selector handle; 16 Amp rating
Black selector handle; 16 Amp rating;
1 NO auxiliary contact
Red/Yellow selector handle; 16 Amp rating
Red/Yellow selector handle; 16 Amp rating;
1 NO auxiliary contact
Black selector handle; 40 Amp rating
Black selector handle; 40 Amp rating;
1 NO auxiliary contact
Red/Yellow selector handle; 40 Amp rating
Red/Yellow selector handle; 40 Amp rating;
1 NO auxiliary contact
Black selector handle; 60 Amp rating
Black selector handle; 60 Amp rating;
1 NO auxiliarycontact
Red/Yellow selector handle; 60 Amp rating
Red/Yellow selector handle; 60 Amp rating;
1 NO auxiliary contact
Black pistol handle; 80 Amp rating
Black pistol handle; 80 Amp rating;
1 NO auxiliary contact
Red/Yellow pistol handle; 80 Amp rating
Red/Yellow pistol handle; 80 Amp rating;
1 NO auxiliary contact
Short Circuit protective device
Controller
12
Overload protection
EOT Motor disconnect
EOT products are properly installed on the load side of a
branch circuit protective device and are suitable for use as
motor disconnects as illustrated above.
HORSEPOWER RATINGS
Model Series
eOT16
Three Phase Max HP
200-208V
3
240V
6
480V
10
600V
10
Single Phase Max HP
120V
1
240V
2
eOT32
eOT45
eOT63
10
10
20
25
15
15
30
30
20
20
40
40
2
5
2
7.5
2
10
MOTOR CONTROLS
ORDERING INFORMATION
Disconnect means
ACCESSORIES
OA1G01 Auxiliary contact NC, mounts on left side of switch only
OA1G10 Auxiliary contact, NO mounts on right side of switch only
OTPL40FP 4th Pole, late-break/early-make function (eOT16 & eOT32)
OTPL80FP 4th Pole, late-break/early-make function (eOT45 & eOT63)
OTPS40FP 4th Pole (EOT16 & eOT32)
OTPS80FP 4th Pole (EOT45 & eOT63)
WE MAKE IT EASY.
kele.com
888-397-5353 USA
689
NEW!
MOTOR CONTROLS
BREAKER COMBINATION MOTOR STARTERS
BCXLS SERIES
DESCRIPTION
Breaker combnation motor starters are UL508. They include
600 Volt internatinally accepted industrial control breakers
with instantaneous and thermal trip. They all have door
handle safety interlocks and pilot lights. Magnetic starters
with percision and consisten overload protection and different
single phasing protection.
FEATURES
•
•
•
•
•
•
•
•
Breakers with instantaneous and thermal trip
NEMA 1 or NEMA 12/4 enclosure
Space and drilling for fused control circuit transformer
HOA switch
Pilot light
Door safety interlocks
24V or 120V coil voltage
UL File #E90628
BCXLS11K-1G-0N-M01-H0A-PL
WIRING
TRANSFORMER
PILOT LIGHTS
H1(L1)
ON PL
H4(L2)
R
A1
H3 H2
L1
12
21
X1
M
OFF PL
22
G
FU
X1
A2
BREAKER COMBINATION
L2
X2
L1
X2
L2
L3
CONTROL CIRCUIT
L1
MOTOR CONTROLS
X1
HAND
OFF
AUTO
13
14
23
24
A1
A2
M
OL
95
96
L2
L2
X2
A1
H1
H4
13
M
2
1
14
Aux. NO
REMOTE SWITCH
L1
X1
STOP
21
22
START
A1
13
14
A2
M
OL
95
X2
A1
M
A2
95
96
L2
OL
96
OL
X2
T1
T2
T3
AUX
13
14
MTR
OFF ON
L1
A1
X1
13
14
A2
M
OL
95
96
L2
X2
FUSIBLE CONTROL TRANSFORMERS
Model
B050MBT713RK
B100MBT713RK
B150MBT713RK
B200MBT713RK
B250MBT713RK
B300MBT713RK
B350MBT713RK
690
Primary Volts
208V, 230V, 460V
208V, 230V, 460V
208V, 230V, 460V
208V, 230V, 460V
208V, 230V, 460V
208V, 230V, 460V
208V, 230V, 460V
888-397-5353 USA
Secondary Volts Continuous VA
115V, 24V
50VA
115V, 24V
100VA
115V, 24V
150VA
115V, 24V
200VA
115V, 24V
250VA
115V, 24V
300VA
115V, 24V
350VA
kele.com
Contactors to use with
LS07,4,7,17,27,37, LS05,4K,7K,11K,18K
LS47,57,77,87,107 ,LS22K,30K,37K,45K, LS55K
LS177, LS75K LS90K(3P)
LS247 LS110K, 132K, 160K
LS220K, 280K, 375K
LS450K
Height
3.25" (83 mm)
3.62"(92 mm)
4.37" (111 mm)
4.5" (114 mm)
5.25" (133 mm)
5.12" (130 mm)
5.37" (137 mm)
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
Width
3.0" (76 mm)
3.75" (95 mm)
3.75" (95 mm)
4.5" (114 mm)
4.5" (114 mm)
5.25" (133 mm)
5.25" (133 mm)
Depth
3.93" (100 mm)
4.55" (76 mm)
4.55" (76 mm)
5.18" (132 mm)
5.18" (132 mm)
6.12" (155 mm)
6.12" (155 mm)
March 2014
NEW!
MOTOR CONTROLS
BREAKER COMBINATION MOTOR STARTERS
BCXLS SERIES
ORDERING INFORMATION/SPECIFICATIONS
Part Number
March 2014
Voltage
5
200/230
Coil
Voltage
24 VAC
120 VAC
24 VAC
10
460
120 VAC
24 VAC
7.5
230
120 VAC
24 VAC
15
460
120 VAC
24 VAC
10
200
120 VAC
24 VAC
10
230
120 VAC
24 VAC
20
460
120 VAC
24 VAC
15
200/230
120 VAC
24 VAC
30
460
120 VAC
24 VAC
20/25
200/230
120 VAC
24 VAC
50
460
120 VAC
24 VAC
25/30
200/230
120 VAC
24 VAC
60
460
120 VAC
24 VAC
40
230
120 VAC
75
460
40/50
200/230
24 VAC
24 VAC
120 VAC
24 VAC
100
460
120 VAC
Enclosure
Coil
NEMA Rating Inrush
1
12/4
45 VA
1
12/4
1
12/4
45 VA
1
12/4
1
12/4
88 VA
1
12/4
1
12/4
88 VA
1
12/4
1
12/4
88 VA
1
12/4
1
12/4
88 VA
1
12/4
1
12/4
88 VA
1
12/4
1
12/4
191 VA
1
12/4
1
12/4
191 VA
1
12/4
1
12/4
191 VA
1
12/4
1
12/4
191 VA
1
12/4
1
12/4
191 VA
1
12/4
1
12/4
191 VA
1
12/4
1
12/4
191 VA
1
12/4
1
12/4
191 VA
1
12/4
1
12/4
400 VA
1
12/4
1
12/4
400 VA
1
12/4
Coil Holding
Current
Overload Breaker
Range
Rating
Dimensions
in (lb)
Weight
lb (kg)
6 VA
14.5-18
Amps
30A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
31 (14.1)
6 VA
14.5-18
Amps
30A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
31 (14.1)
9 VA
21-26 Amps
50A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
32 (14.5)
9 VA
21-26 Amps
50A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
32 (14.5)
9 VA
30-40 Amps
80A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
33 (15)
9 VA
30-40 Amps
80A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
33 (15)
9 VA
30-40 Amps
80A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
33 (15)
17 VA
54-65 Amps
125A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
45 (20.4)
17 VA
42-55 Amps
100A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
45 (20.4)
17 VA
64-82 Amps
150A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
47 (21.3)
17 VA
64-82 Amps
150A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
47 (21.3)
17 VA
78-97 Amps
150A
24" x 20" x 8"
(61 x 50.8 x 20.3)
61 (27.7)
17 VA
78-97 Amps
150A
24" x 20" x 8"
(61 x 50.8 x 20.3)
61 (27.7)
17 VA
90-110 Amps
175A
24" x 20" x 8"
(61 x 50.8 x 20.3)
63 (28.6)
17 VA
90-110 Amps
175A
24" x 20" x 8"
(61 x 50.8 x 20.3)
63 (28.6)
32 VA
140-190
Amps
225A
30" x 24" x 8"
(76.2 x 61 x 20.3)
97 (44)
32 VA
140-190
Amps
225A
30" x 24" x 8"
(76.2 x 61 x 20.3)
97 (44)
WE MAKE IT EASY.
kele.com
888-397-5353 USA
12
MOTOR CONTROLS
BCXLS7K-1G-O-M01-HOA-PL
BCXLS7K-1G-O-M4-HOA-PL
BCXLS7K-1A-O-M01-HOA-PL
BCXLS7K-1A-O-M4-HOA-PL
BCXLS7K-2G-O-M01-HOA-PL
BCXLS7K-2G-O-M4-HOA-PL
BCXLS7K-2A-O-M01-HOA-PL
BCXLS7K-2A-O-M4-HOA-PL
BCXLS11K-1G-ON-M01-HOA-PL
BCXLS11K-1G-ON-M4-HOA-PL
BCXLS11K-1A-ON-M01-HOA-PL
BCXLS11K-1A-ON-M4-HOA-PL
BCXLS11K-2G-ON-M01-HOA-PL
BCXLS11K-2G-ON-M4-HOA-PL
BCXLS11K-2A-ON-M01-HOA-PL
BCXLS11K-2A-ON-M4-HOA-PL
BCXLS15K-1G-Q-M01-HOA-PL
BCXLS15K-1G-Q-M4-HOA-PL
BCXLS15K-1A-Q-M01-HOA-PL
BCXLS15K-1A-Q-M4-HOA-PL
BCXLS15K-2G-Q-M01-HOA-PL
BCXLS15K-2G-Q-M4-HOA-PL
BCXLS15K-2A-Q-M01-HOA-PL
BCXLS15K-2A-Q-M4-HOA-PL
BCXLS15K-3G-Q-M01-HOA-PL
BCXLS15K-3G-Q-M4-HOA-PL
BCXLS15K-3A-Q-M01-HOA-PL
BCXLS15K-3A-Q-M4-HOA-PL
BCXLS22K-1G-RN-M01-HOA-PL
BCXLS22K-1G-RN-M4-HOA-PL
BCXLS22K-1A-RN-M01-HOA-PL
BCXLS22K-1A-RN-M4-HOA-PL
BCXLS22K-2G-QN-M01-HOA-PL
BCXLS22K-2G-QN-M4-HOA-PL
BCXLS22K-2A-QN-M01-HOA-PL
BCXLS22K-2A-QN-M4-HOA-PL
BCXLS37K-1G-SN-M01-HOA-PL
BCXLS37K-1G-SN-M4-HOA-PL
BCXLS37K-1A-SN-M01-HOA-PL
BCXLS37K-1A-SN-M4-HOA-PL
BCXLS37K-2G-SN-M01-HOA-PL
BCXLS37K-2G-SN-M4-HOA-PL
BCXLS37K-2A-SN-M01-HOA-PL
BCXLS37K-2A-SN-M4-HOA-PL
BCXLS45K-1G-TM-M01-HOA-PL
BCXLS45K-1G-TM-M4-HOA-PL
BCXLS45K-1A-TM-M01-HOA-PL
BCXLS45K-1A-TM-M4-HOA-PL
BCXLS45K-2G-TM-M01-HOA-PL
BCXLS45K-2G-TM-M4-HOA-PL
BCXLS45K-2A-TM-M01-HOA-PL
BCXLS45K-2A-TM-M4-HOA-PL
BCXLS55K-1G-TN-M01-HOA-PL
BCXLS55K-1G-TN-M4-HOA-PL
BCXLS55K-1A-TN-M01-HOA-PL
BCXLS55K-1A-TN-M4-HOA-PL
BCXLS55K-2G-TN-M01-HOA-PL
BCXLS55K-2G-TN-M4-HOA-PL
BCXLS55K-2A-TN-M01-HOA-PL
BCXLS55K-2A-TN-M4-HOA-PL
BCXLS75K-1G-TT-M01-HOA-PL
BCXLS75K-1G-TT-M4-HOA-PL
BCXLS75K-1A-TT-M01-HOA-PL
BCXLS75K-1A-TT-M4-HOA-PL
BCXLS75K-2G-TT-M01-HOA-PL
BCXLS75K-2G-TT-M4-HOA-PL
BCXLS75K-2A-TT-M01-HOA-PL
BCXLS75K-2A-TT-M4-HOA-PL
HP
691
NEW!
MOTOR CONTROLS
FUSIBLE AND NON-FUSIBLE MOTOR STARTERS
FCXLS, NFCXLS SERIES
DESCRIPTION
Fusible and Non-Fusible combination controls for your
motor. These have UL/CSA manual motor disconnects with
door safety interlocks. Industrial controls disconnects are
load make, load break, UL listed for motor load switching
duty. Starter and overload relay complete with precision
ambient compensated heaters and differential single phasing
protection.
FEATURES
•
•
•
•
•
•
•
NEMA 1 or NEMA 12/4 enclosure
Space and drilling for fused control circuit transformer
HOA switch
Pilot light
Door safety interlocks
24V or 120V coil voltage
UL File #E90628
FCXLS7K-2A-0-M4-HOA-PL
WIRING
TRANSFORMER
PILOT LIGHTS
H1(L1)
H4(L2)
ON PL
R
A1
H3 H2
L1
FU
12
21
X1
X1
M
OFF PL
22
G
A2
L2
FUSIBLE COMBINATION
X2
L1
X2
L2
L3
CONTROL CIRCUIT
L1
X1
HAND
OFF
13
AUTO
A1
14
M
A2
OL
95
96
L2
L2
X2
A1
MOTOR CONTROLS
H1
23
24
1
H4
2
M
REMOTE SWITCH
L1
X1
STOP
21
22
A1
A2
OL
95
96
M
L2
95
X2
M
T1
A1
X1
96
T2
T3
MTR
OFF ON
L1
OL
OL
14
AUX
13
14
13
A1
A2
START
13
X2
14
M
A2
OL
95
96
L2
X2
FUSIBLE CONTROL TRANSFORMERS
Model
B050MBT713RK
B100MBT713RK
B150MBT713RK
B200MBT713RK
B250MBT713RK
B300MBT713RK
B350MBT713RK
692
Primary Volts
208V, 230V, 460V
888-397-5353 USA
Secondary Volts Continuous VA
Contactors to use with
50VA
LS07,4,7,17,27,37, LS05,4K,7K,11K,18K
100VA
LS47,57,77,87,107 ,LS22K,30K,37K,45K, LS55K
150VA
LS177, LS75K LS90K(3P)
115V, 24V
200VA
LS247 LS110K, 132K, 160K
250VA
LS220K, 280K, 375K
300VA
LS450K
350VA
kele.com
Height
Width
3.25" (83mm)
3.0" (76mm)
3.62"(92mm) 3.75" (95mm)
4.37" (111mm) 3.75" (95mm)
4.5" (114mm) 4.5" (114mm)
5.25" (133mm) 4.5" (114mm)
5.12" (130mm) 5.25" (133mm)
5.37" (137mm) 5.25" (133mm)
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
Depth
3.93" (100mm
4.55" (76mm)
4.55" (76mm)
5.18" (132mm)
5.18" (132mm)
6.12" (155mm)
6.12" (155mm)
March 2014
NEW!
MOTOR CONTROLS
FUSIBLE AND NON-FUSIBLE MOTOR STARTERS
FCXLS, NFCXLS SERIES
ORDERING INFORMATION - FCXLS
Part
Number
FCXLS7K-1G-O-M01-HOA-PL
FCXLS7K-1G-O-M4-HOA-PL
FCXLS7K-1A-O-M01-HOA-PL
FCXLS7K-1A-O-M4-HOA-PL
FCXLS7K-2G-O-M01-HOA-PL
FCXLS7K-2G-O-M4-HOA-PL
FCXLS7K-2A-O-M01-HOA-PL
FCXLS7K-2A-O-M4-HOA-PL
FCXLS11K-1G-ON-M01-HOA-PL
FCXLS11K-1G-ON-M4-HOA-PL
FCXLS11K-1A-ON-M01-HOA-PL
FCXLS11K-1A-ON-M4-HOA-PL
FCXLS11K-2G-ON-M01-HOA-PL
FCXLS11K-2G-ON-M4-HOA-PL
FCXLS11K-2A-ON-M01-HOA-PL
FCXLS11K-2A-ON-M4-HOA-PL
FCXLS15K-1G-Q-M01-HOA-PL
FCXLS15K-1G-Q-M4-HOA-PL
FCXLS15K-1A-Q-M01-HOA-PL
FCXLS15K-1A-Q-M4-HOA-PL
FCXLS15K-2G-Q-M01-HOA-PL
FCXLS15K-2G-Q-M4-HOA-PL
FCXLS15K-2A-Q-M01-HOA-PL
FCXLS15K-2A-Q-M4-HOA-PL
FCXLS15K-3G-Q-M01-HOA-PL
FCXLS15K-3G-Q-M4-HOA-PL
March 2014
Voltage
5
200/230
10
460
Coil
Enclosure
Coil Coil Holding Overload Fuse Block
Voltage NEMA Rating Inrush
Current
Range
Rating
24 VAC
120 VAC
24 VAC
120 VAC
7.5
230
15
460
10
200
10
230
20
460
15
200/230
30
460
20/25
200/230
50
460
25/30
200/230
60
460
40
230
75
460
40/50
200/230
100
460
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
24 VAC
120 VAC
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
1
12/4
14.5-18
Dimensions
in (cm)
Weight
lb (kg)
30A
12" x 10" x 6"
(30.5 x 25.4 x 15.2)
18 (8.16)
30A
12" x 10" x 6"
(30.5 x 25.4 x 15.2)
18 (8.16)
45 VA
6 VA
45 VA
6 VA
88 VA
9 VA
21-26 Amps
60A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
18 (8.16)
88 VA
9 VA
21-26 Amps
30A
12" x 10" x 6"
(30.5 x 25.4 x 15.2)
18 (8.16)
18 (8.16)
18 (8.16)
18 (8.16)
88 VA
9 VA
30-40 Amps
60A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
27 (12.2)
88 VA
9 VA
30-40 Amps
60A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
27 (12.2)
88 VA
9 VA
30-40 Amps
60A
16" x 12" x 8"
(40.6 x 30.5 x 20.3)
27 (12.2)
191 VA
17 VA
54-65 Amps
100A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
41 (18.6)
191 VA
17 VA
42-55 Amps
60A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
41 (18.6)
191 VA
17 VA
64-82 Amps
100A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
42 (19.1)
191 VA
17 VA
64-82 Amps
100A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
42 (19.1)
191 VA
17 VA
78-97 Amps
100A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
44 (20)
191 VA
17 VA
78-97 Amps
100A
20" x 16" x 8"
(50.8 x 40.6 x 20.3)
44 (20)
191 VA
17 VA
90-110 Amps
200A
30" x 24" x 8"
(76.2 x 61 x 20.3)
88 (40)
191 VA
17 VA
90-110 Amps
200A
30" x 24" x 8"
(76.2 x 61 x 20.3)
88 (40)
400 VA
32 VA
140-190
Amps
200A
36" x 24" x 10"
(91.4 x 61 x 25.4)
124 (56.2)
400 VA
32 VA
140-190
Amps
200A
36" x 24" x 10"
(91.4 x 61 x 25.4)
124 (56.2)
14.5-18
Amps
WE MAKE IT EASY.
kele.com
888-397-5353 USA
12
MOTOR CONTROLS
FCXLS15K-3A-Q-M01-HOA-PL
FCXLS15K-3A-Q-M4-HOA-PL
FCXLS22K-1G-RN-M01-HOA-PL
FCXLS22K-1G-RN-M4-HOA-PL
FCXLS22K-1A-RN-M01-HOA-PL
FCXLS22K-1A-RN-M4-HOA-PL
FCXLS22K-2G-QN-M01-HOA-PL
FCXLS22K-2G-QN-M4-HOA-PL
FCXLS22K-2A-QN-M01-HOA-PL
FCXLS22K-2A-QN-M4-HOA-PL
FCXLS37K-1G-SN-M01-HOA-PL
FCXLS37K-1G-SN-M4-HOA-PL
FCXLS37K-1A-SN-M01-HOA-PL
FCXLS37K-1A-SN-M4-HOA-PL
FCXLS37K-2G-SN-M01-HOA-PL
FCXLS37K-2G-SN-M4-HOA-PL
FCXLS37K-2A-SN-M01-HOA-PL
FCXLS37K-2A-SN-M4-HOA-PL
FCXLS45K-1G-TM-M01-HOA-PL
FCXLS45K-1G-TM-M4-HOA-PL
FCXLS45K-1A-TM-M01-HOA-PL
FCXLS45K-1A-TM-M4-HOA-PL
FCXLS45K-2G-TM-M01-HOA-PL
FCXLS45K-2G-TM-M4-HOA-PL
FCXLS45K-2A-TM-M01-HOA-PL
FCXLS45K-2A-TM-M4-HOA-PL
FCXLS55K-1G-TN-M01-HOA-PL
FCXLS55K-1G-TN-M4-HOA-PL
FCXLS55K-1A-TN-M01-HOA-PL
FCXLS55K-1A-TN-M4-HOA-PL
FCXLS55K-2G-TN-M01-HOA-PL
FCXLS55K-2G-TN-M4-HOA-PL
FCXLS55K-2A-TN-M01-HOA-PL
FCXLS55K-2A-TN-M4-HOA-PL
FCXLS75K-1G-TT-M01-HOA-PL
FCXLS75K-1G-TT-M4-HOA-PL
FCXLS75K-1A-TT-M01-HOA-PL
FCXLS75K-1A-TT-M4-HOA-PL
FCXLS75K-2G-TT-M01-HOA-PL
FCXLS75K-2G-TT-M4-HOA-PL
FCXLS75K-2A-TT-M01-HOA-PL
FCXLS75K-2A-TT-M4-HOA-PL
HP
693
NEW!
MOTOR CONTROLS
FUSIBLE AND NON-FUSIBLE MOTOR STARTERS
FCXLS, NFCXLS SERIES
ORDERING INFORMATION - NFCXLS
Part Number
MOTOR CONTROLS
12
NFCXLS7K-1G-O-M01-HOA-PL
NFCXLS7K-1G-O-M4-HOA-PL
NFCXLS7K-1A-O-M01-HOA-PL
NFCXLS7K-1A-O-M4-HOA-PL
NFCXLS7K-2G-O-M01-HOA-PL
NFCXLS7K-2G-O-M4-HOA-PL
NFCXLS7K-2A-O-M01-HOA-PL
NFCXLS7K-2A-O-M4-HOA-PL
NFCXLS11K-1G-ON-M01-HOA-PL
NFCXLS11K-1G-ON-M4-HOA-PL
NFCXLS11K-1A-ON-M01-HOA-PL
NFCXLS11K-1A-ON-M4-HOA-PL
NFCXLS11K-2G-ON-M01-HOA-PL
NFCXLS11K-2G-ON-M4-HOA-PL
NFCXLS11K-2A-ON-M01-HOA-PL
NFCXLS11K-2A-ON-M4-HOA-PL
NFCXLS15K-1G-Q-M01-HOA-PL
NFCXLS15K-1G-Q-M4-HOA-PL
NFCXLS15K-1A-Q-M01-HOA-PL
NFCXLS15K-1A-Q-M4-HOA-PL
NFCXLS15K-2G-Q-M01-HOA-PL
NFCXLS15K-2G-Q-M4-HOA-PL
NFCXLS15K-2A-Q-M01-HOA-PL
NFCXLS15K-2A-Q-M4-HOA-PL
NFCXLS15K-3G-Q-M01-HOA-PL
NFCXLS15K-3G-Q-M4-HOA-PL
NFCXLS15K-3A-Q-M01-HOA-PL
NFCXLS15K-3A-Q-M4-HOA-PL
NFCXLS22K-1G-RN-M01-HOA-PL
NFCXLS22K-1G-RN-M4-HOA-PL
NFCXLS22K-1A-RN-M01-HOA-PL
NFCXLS22K-1A-RN-M4-HOA-PL
NFCXLS22K-2G-QN-M01-HOA-PL
NFCXLS22K-2G-QN-M4-HOA-PL
NFCXLS22K-2A-QN-M01-HOA-PL
NFCXLS22K-2A-QN-M4-HOA-PL
NFCXLS37K-1G-SN-M01-HOA-PL
NFCXLS37K-1G-SN-M4-HOA-PL
NFCXLS37K-1A-SN-M01-HOA-PL
NFCXLS37K-1A-SN-M4-HOA-PL
NFCXLS37K-2G-SN-M01-HOA-PL
NFCXLS37K-2G-SN-M4-HOA-PL
NFCXLS37K-2A-SN-M01-HOA-PL
NFCXLS37K-2A-SN-M4-HOA-PL
NFCXLS45K-1G-TM-M01-HOA-PL
NFCXLS45K-1G-TM-M4-HOA-PL
NFCXLS45K-1A-TM-M01-HOA-PL
NFCXLS45K-1A-TM-M4-HOA-PL
NFCXLS45K-2G-TM-M01-HOA-PL
NFCXLS45K-2G-TM-M4-HOA-PL
NFCXLS45K-2A-TM-M01-HOA-PL
NFCXLS45K-2A-TM-M4-HOA-PL
NFCXLS55K-1G-TN-M01-HOA-PL
NFCXLS55K-1G-TN-M4-HOA-PL
NFCXLS55K-1A-TN-M01-HOA-PL
NFCXLS55K-1A-TN-M4-HOA-PL
NFCXLS55K-2G-TN-M01-HOA-PL
NFCXLS55K-2G-TN-M4-HOA-PL
NFCXLS55K-2A-TN-M01-HOA-PL
NFCXLS55K-2A-TN-M4-HOA-PL
NFCXLS75K-1G-TT-M01-HOA-PL
NFCXLS75K-1G-TT-M4-HOA-PL
NFCXLS75K-1A-TT-M01-HOA-PL
NFCXLS75K-1A-TT-M4-HOA-PL
NFCXLS75K-2G-TT-M01-HOA-PL
NFCXLS75K-2G-TT-M4-HOA-PL
NFCXLS75K-2A-TT-M01-HOA-PL
NFCXLS75K-2A-TT-M4-HOA-PL
694
HP
Voltage
5
200/230
10
460
7.5
230
15
460
10
200
10
230
20
460
15
200/230
30
460
20/25
200/230
50
460
25/30
200/230
60
460
40
230
75
460
40/50
200/230
100
460
888-397-5353 USA
kele.com
Coil
Enclosure
Coil
Voltage NEMA Rating Inrush
1
24 VAC
12/4
45 VA
1
120 VAC
12/4
1
24 VAC
12/4
45 VA
1
120 VAC
12/4
1
24 VAC
12/4
88 VA
1
120 VAC
12/4
1
24 VAC
12/4
88 VA
1
120 VAC
12/4
1
24 VAC
12/4
88 VA
1
120 VAC
12/4
1
24 VAC
12/4
88 VA
1
120 VAC
12/4
1
24 VAC
12/4
88 VA
1
120 VAC
12/4
1
24 VAC
12/4
191 VA
1
120 VAC
12/4
1
24 VAC
12/4
191 VA
1
120 VAC
12/4
1
24 VAC
12/4
191 VA
1
120 VAC
12/4
1
24 VAC
12/4
191 VA
1
120 VAC
12/4
1
12/4
24 VAC
191 VA
120 VAC
1
12/4
1
24 VAC
12/4
191 VA
1
120 VAC
12/4
1
24 VAC
12/4
191 VA
1
120 VAC
12/4
1
24 VAC
12/4
191 VA
1
120 VAC
12/4
1
24 VAC
12/4
400 VA
1
120 VAC
12/4
1
24 VAC
12/4
400 VA
1
120 VAC
12/4
Coil Holding
Current
Overload
Range
Dimensions
in (cm)
Weight
lb (kg)
6 VA
14.5-18
Amps
12" x 10" x 6" (30.5 x 25.4 x 15.2)
17 (7.7)
6 VA
14.5-18
Amps
12" x 10" x 6" (30.5 x 25.4 x 15.2)
17 (7.7)
9 VA
21-26 Amps
12" x 10" x 6" (30.5 x 25.4 x 15.2)
17 (7.7)
9 VA
21-26 Amps
12" x 10" x 6" (30.5 x 25.4 x 15.2)
17 (7.7)
9 VA
30-40 Amps
12" x 10" x 6" (30.5 x 25.4 x 15.2)
18 (8.2)
9 VA
30-40 Amps
12" x 10" x 6" (30.5 x 25.4 x 15.2)
18 (8.2)
9 VA
30-40 Amps
12" x 10" x 6" (30.5 x 25.4 x 15.2)
18 (8.2)
17 VA
54-65 Amps
16" x 12" x 8" (40.6 x 30.5 x 20.3)
27 (12.2)
17 VA
42-55 Amps
16" x 12" x 8" (40.6 x 30.5 x 20.3)
27 (12.2)
17 VA
64-82 Amps
16" x 12" x 8" (40.6 x 30.5 x 20.3)
28 (12.7)
17 VA
64-82 Amps
16" x 12" x 8" (40.6 x 30.5 x 20.3)
28 (12.7)
17 VA
78-97 Amps
20" x 16" x 8" (50.8 x 40.6 x 20.3)
38 (17.2)
17 VA
78-97 Amps
20" x 16" x 8" (50.8 x 40.6 x 20.3)
38 (17.2)
17 VA
90-110
Amps
20" x 16" x 8" (50.8 x 40.6 x 20.3)
40 (18.1)
17 VA
90-110
Amps
20" x 16" x 8" (50.8 x 40.6 x 20.3)
40 (18.1)
32 VA
140-190
Amps
24" x 20" x 8" (60.1 x 50.8 x 20.3)
65 (29.4)
32 VA
140-190
Amps
24" x 20" x 8" (60.1 x 50.8 x 20.3)
65 (29.4)
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVES
CORE VFD
DESCRIPTION
CORE VFDs are an economical option drive option with easy
to set up functionality. The firmware includes special features
that make start-up and commissioning of HVAC applications
especially easy. The Wizard consists of critical commissioning
questions to intuitively guide users through parameter
setup process, which covers nearly all your commercial
heating, ventilation and air conditioning (HVAC) applications.
Additionally, the VFD CORE is rated for constant torque for
industrial applications. The CORE VFD line is also available
with a bypass option which is also easy to integrate. The
by-pass comes with a control transformer, time delay fuses,
3 contactors, primary and secondary fuses. The CORE line of
VFDs is a time saver as well as an energy saver.
FEATURES
•
•
•
•
•
Intuitive commissioning
Start-up wizard
Real-time clock
Detachable keypad
PID with sleep control
HCRDA005DA1000T
SPECIFICATIONS
Supply Voltage
Relay Outputs
Filter Type
2; SPDT 8A at 24VDC or 250 VAC
0.4A at 125 VDC minimum load
10mA at 5 VAC/VDC
5% DC choke (Frame D and E
standard; 3% built in) -- Optional for
frames A, B, C
Class 2 GMC/ RFI
EMC
Complies with EN50082-1, -2
EN61800-3
Communication Protocol
RS485
MODBUS, BACnet
Operating Humidity
0 to 90% RH, non-condensing
Operating Temperature14° to 104°F (-10° to 40°C)
Approvals
UL Listed File E190898, CE, RoHS
Eco Friendly
Yes
Warranty
3 years
DIMENSIONS AND WEIGHTS
Frame
208/230 VAC
460 VAC
A
B
B
C
C
C
D
D
E
E
E
1.0 - 7.5 HP
10 - 15 HP
20 HP
25 - 40 HP
1.0 - 10 HP
15 HP
20 - 25 HP
March 2014
50 - 60 HP
75 HP
100 HP
125 HP
30 - 40 HP
50 HP
60 - 75 HP
100 - 125 HP
Enclosure
NEMA type
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
Width
in (cm)
5.12 (13.0)
7.48 (19.0)
7.48 (19.0)
9.84 (25.0)
9.84 (25.0)
9.84 (25.0)
12.99 (33.0)
12.99 (33.0)
14.57 (37.0)
14.57 (37.0)
14.57 (37.0)
Height
in (cm)
9.84 (25.0)
12.6 (32.0)
12.6 (32.0)
15.75 (40.0)
15.75 (40.0)
15.75 (40.0)
27.10 (68.83)
27.10 (68.83)
28.18 (71.58)
28.18 (71.58)
28.18 (71.58)
WE MAKE IT EASY.
kele.com
Depth
in (cm)
6.69 (17.0)
7.48 (19.0)
7.48 (19.0)
8.27 (21.0)
8.27 (21.0)
8.27 (21.0)
10.83 (27.5)
10.83 (27.5)
11.81 (30.0)
11.81 (30.0)
11.81 (30.0)
888-397-5353 USA
12
MOTOR CONTROLS
Model specific, 3 phase, 60 Hz,
380-480 VAC or 200-240 VAC
Motor Rating
0.75 to 250 Hp
Frequency Range
0-320 Hz
Acceleration Time
0.1 - 3000 seconds
Deceleration Time
0.1 - 3000 seconds
Digital Input
6 logical, 24 VDC= on, 0 VDC= off,
all configurable
Analog Input
2; 0-010v or 4-20 mA voltage
Input impedance 200Ω k
Current impedance 250Ω
Digital Output
Open collector, max. load
48V/ 50 mA
Analog Output
1; 0-10 VDC or 4-20 mA
programmable
500Ω maximum load
Weight
lb (kg)
6.17 (2.8)
10.14 (4.6)
12.35 (5.6)
23.15 (10.5)
19.18 (8.7)
20.72 (9.4)
78.26 (35.5)
89.29 (40.5)
100.75 (45.7)
101.85 (46.2)
120.59 (54.7)
695
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVES
CORE VFD
WIRING
DC CHOKE
(OPTIONAL)
3-PHASE POWER IS PROVIDED
JUMPER
BREAKING RESISTOR
(OPTIONAL)
FUSE/NO FUSE BREAKER
R(L1) NFB
R(L1)
U(T1)
S(L2)
S(L2)
V(T2)
T(L3)
T(L3)
W(T3)
3-PHASE POWER IS PROVIDED
MOTOR
+1/DC+
FRAME E
IM
3~
R
r
S
s
-/DC+
U(T1)
MOTOR
IM
3~
V(T2)
W(T3)
FUSE/NO FUSE BREAKER
R(L1) NFB
FACTORY SETTING:
PNP SOURCE
RA1 (RELAY OUT 1): RUN
RA2 (RELAY OUT 2): FAULT
RA3 (RELAY OUT 3): READY
DCM
COM
FACTORY
SETTING
+24V
+24V
FWD/STOP
REV/STOP
PRESET SPD 1
PRESET SPD 2
PRESET SPD3
PRESET SPD 4
EXT FAULT
FAULT RESET
NA
NA
FWD
REV
MI1
MI2
MI3
MI4
MI5
MI6
MI7
MI8
DIGITAL SIGNAL COMMON TERMINAL WHILE
USING INTERNAL POWER TO RUN SINK MODE
POWER REMOVAL SAFETY FUNCTION
FOR EMERGENCY STOP
DIGITAL SIGNAL COMMON TERMINAL
+10V/20mA
12
3
5KΩ 2
1
0~10V/0~20mA
0-20mA/0~10V
0~+10V
ANALOG SIGNAL
COMMON TERMINAL
MAIN CIRCUIT (POWER)
TERMINALS
MODBUS RS-485
CONTROL
SG+
PIN 1~2, 7, 8:
TERMINALS
RESERVED
SGSHIELDED
PIN 3, 6: GND
LEADS &
PIN 4: SGCABLES
PIN 5: SG+
MOTOR CONTROLS
MULTI-FUNCTION
OUTPUT TERMINALS
RA1
RB1
RC1
RA2
RC2
RA3
DCM
S1
RC3
S(L2)
T(L3)
T(L3)
FACTORY SETTING:
PNP SOURCE
DCM
250VAC/6A
30VDC/6A
FACTORY
SETTING
MULTI-FUNCTION OUTPUT
FREQUENCY TERMINALS
250VAC/5A
30VDC/5A
MULTI-FUNCTION OUTPUT
FREQUENCY TERMINALS
250VAC/5A
R(L1)
S(L2)
COM
+24V
+24V
FWD
REV
MI1
MI2
MI3
MI4
MI5
MI6
MI7
MI8
FWD/STOP
REV/STOP
PRESET SPD 1
PRESET SPD 2
PRESET SPD 3
PRESET SPD 4
EXT FAULT
FAULT RESET
NA
NA
DIGITAL SIGNAL COMMON TERMINAL WHILE
USING INTERNAL POWER TO RUN SINK MODE
30VDC/5A
POWER REMOVAL SAFETY FUNCTION
FOR EMERGENCY STOP
DIGITAL SIGNAL COMMON TERMINAL
SCM
+10V
AVI1
AFM1
ACI
ACM
AVI2
ACM
AFM2
8 1 8 1
+10V/20mA
ANALOG MULTI-FUNCTION
OUTPUT TERMINAL
0~10V/0~20mA
5KΩ
ANALOG SIGNAL
COMMON TERMINAL
3
2
1
0~10V/0~20mA
0-20mA/0~10V
ANALOG SIGNAL
COMMON TERMINAL
OPTION SLOT 1
COMMUNICATION EXTENSION CARD
OPTION SLOT 3
I/O & RELAY EXTENSION CARD
MAIN CIRCUIT
(POWER)
TERMINALS
CONTROL
TERMINALS
MI: MULTIFUNCTION INPUT
AVI: ANALOG VOLTAGE INPUT
ACI: ANALOG CURRENT INPUT
MULTI-FUNCTION
OUTPUT TERMINALS
RA1
RB1
MODBUS RS-485
SG+
PIN 1~2, 7, 8:
RESERVED
SGPIN 3, 6: GND
PIN 4: SGPIN 5: SG+
30VDC/6A
RA2
250VAC/5A
RC2
RA3
DCM
S1
RC3
AVI1
MULTI-FUNCTION OUTPUT
FREQUENCY TERMINALS
30VDC/5A
AFM1
ACI
ACM
AVI2
ACM
AFM2
30VDC/5A
MULTI-FUNCTION OUTPUT
FREQUENCY TERMINALS
250VAC/5A
SCM
8 1 8 1
250VAC/6A
RC1
+10V
0~+10V
ANALOG MULTI-FUNCTION
OUTPUT TERMINAL
0~10V/0~20mA
RA1 (RELAY OUT 1): RUN
RA2 (RELAY OUT 2): FAULT
RA3 (RELAY OUT 3): READY
ANALOG MULTI-FUNCTION
OUTPUT TERMINAL
0~10V/0~20mA
ANALOG SIGNAL
COMMON TERMINAL
ANALOG MULTI-FUNCTION
OUTPUT TERMINAL
0~10V/0~20mA
OPTION SLOT 1
COMMUNICATION EXTENSION CARD
OPTION SLOT 3
I/O & RELAY EXTENSION CARD
SHIELDED
LEADS &
CABLES
MI: MULTIFUNCTION INPUT
AVI: ANALOG VOLTAGE INPUT
ACI: ANALOG CURRENT INPUT
Frame Sizes D and E
Frame Sizes A, B, and C
M1
M2
M8
DCM
COM
+24V
INTERNAL CIRCUIT
Source Mode with internal power (+24 VDC)
696
888-397-5353 USA
kele.com
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVES
CORE VFD
ORDERING INFORMATION
March 2014
DESCRIPTION
Core VFD 230 V, 2 HP, NEMA 1
Core VFD 230 V, 3 HP, NEMA 1
Core VFD 230 V, 5 HP, NEMA 1
Core VFD 230 V, 7.5 HP, NEMA 1
Core VFD 230 V, 10 HP, NEMA 1
Core VFD 230 V, 15 HP, NEMA 1
Core VFD 230 V, 20 HP, NEMA 1
Core VFD 230 V, 25 HP, NEMA 1
Core VFD 230 V, 30 HP, NEMA 1
Core VFD 230 V, 40 HP, NEMA 1
Core VFD 230 V, 50 HP, NEMA 1
Core VFD 230 V, 60 HP, NEMA 1
Core VFD 230 V, 75 HP, NEMA 1
Core VFD 230 V, 100 HP, NEMA 1
Core VFD 230 V, 125 HP, NEMA 1
Core VFD 460 V, 1 HP, NEMA 1
Core VFD 460 V, 2 HP, NEMA 1
Core VFD 460 V, 3 HP, NEMA 1
Core VFD 460 V, 5 HP, NEMA 1
Core VFD 460 V, 7.5 HP, NEMA 1
Core VFD 460 V, 10 HP, NEMA 1
Core VFD 460 V, 15 HP, NEMA 1
Core VFD 460 V, 20 HP, NEMA 1
Core VFD 460 V, 25 HP, NEMA 1
Core VFD 460 V, 30 HP, NEMA 1
Core VFD 460 V, 40 HP, NEMA 1
Core VFD 460 V, 50 HP, NEMA 1
Core VFD 460 V, 60 HP, NEMA 1
Core VFD 460 V, 75 HP, NEMA 1
Core VFD 460 V, 100 HP, NEMA 1
Core VFD 460 V, 125 HP, NEMA 1
Core VFD 230 V, 1 HP, NEMA 1
WE MAKE IT EASY.
kele.com
12
MOTOR CONTROLS
MODEL
HCRDA0020A1000T
HCRDA0030A1000T
HCRDA0050A1000T
HCRDA0075A1000T
HCRDA0100B1000T
HCRDA0150B1000T
HCRDA0200B1000T
HCRDA0250C1000T
HCRDA0300C1000T
HCRDA0400C1000T
HCRDA0500D1000T
HCRDA0600D1000T
HCRDA0750E1000T
HCRDA1000E1000T
HCRDA1250E1000T
HCRDC0010A1000T
HCRDC0020A1000T
HCRDC0030A1000T
HCRDC0050A1000T
HCRDC0075A1000T
HCRDC0100A1000T
HCRDC0150B1000T
HCRDC0200B1000T
HCRDC0250B1000T
HCRDC0300C1000T
HCRDC0400C1000T
HCRDC0500C1000T
HCRDC0600D1000T
HCRDC0750D1000T
HCRDC1000D1000T
HCRDC1250D1000T
HCRDA0010A1000T
888-397-5353 USA
697
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVES
CORE VFD WITH BYPASS
DESCRIPTION
The CORE VFD with a bypass option comes with a control
transformer, time delay fuses, three contactors, primary and
secondary fuses. CORE VFDs are an economical option drive
option with easy to set up functionality. The firmware includes
special features that make start-up and commissioning of
HVAC applications especially easy. The Wizard consists of
critical commissioning questions to intuitively guide users
through a parameter setup process, which covers nearly all
your commercial heating, ventilation and air conditioning
(HVAC) applications. Additionally, the VFD CORE is rated for
constant torque for industrial applications. The CORE line of
VFDs is a time saver as well as an energy saver.
FEATURES
•
•
•
•
•
Intuitive commissioning
Start-up wizard
Real-time clock
Detachable keypad
PID with sleep control
Core VFD with Bypass
MOTOR CONTROLS
12
SPECIFICATIONS
Supply Voltage
Model specific, 3 phase, 60 Hz, 380480 VAC or 200-240 VAC
Motor Rating
0.75 to 250 Hp
Frequency Range
0-320 Hz
Acceleration Time
0.1 - 3000 seconds
Deceleration Time
0.1 - 3000 seconds
Digital Inputs
6 logical, 24 VDC = on, 0 VDC = off,
all configurable
Analog Input
2; 0-010V or 4-20 mA voltage
Input Impedance
200Ω k
Current Impedance
250Ω
Digital Output
Open collector, max. load 48V/ 50
mA
Analog Output
1; 0-10 VDC or 4-20 mA
programmable
500Ω maximum load
Relay Outputs
Filter Type
2; SPDT 8A at 24VDC or 250 VAC
0.4A at 125 VDC minimum load
10mA at 5 VAC/VDC
5% DC choke optional on frames
A, B, and C
Class 2 GMC/ RFI
EMC
Complies with EN50082-1, -2
EN61800-3
Communication Protocol
RS485
MODBUS, BACnet
Operating Humidity
0 to 90% RH, non-condensing
Operating Temperature14° to 104°F (-10° to 40°C)
Approvals
UL Listed File #E190898, CE, RoHS
Eco Friendly
Yes
Warranty
3 years
DIMENSIONS AND WEIGHTS
Frame
208/230 VAC
460 VAC
Enclosure
NEMA type
Width
in (cm)
Height
in (cm)
Depth
in (cm)
Weight
lb (kg)
A
1.0 - 7.5 HP
1.0 - 10 HP
NEMA 1
8.9 (22.7)
22.0 (55.9)
9.3 (23.6)
37.0 (16.78)
698
B
10 - 20 HP
15 - 25 HP
NEMA 1
12.4 (31.6)
48.0 (121.9)
9.66 (24.5)
67.0(30.39)
C
25 - 40 hp
30 - 50 HP
NEMA 1
12.4 (31.6)
48.0 (121.9)
9.66 (24.5)
83.0 (37.65)
D
50 - 60 HP
60 - 125 HP
NEMA 1
19.5 (49.7)
53.5 (135.9)
11.4 (29.1)
193.0 (87.54)
E
75 - 125 HP
NEMA 1
23.0 (48.3)
66.5 (168.9)
14.4 (36.7)
225 (102.06)
888-397-5353 USA
kele.com
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVES
CORE VFD WITH BYPASS
WIRING
DC CHOKE
(OPTIONAL)
3-PHASE POWER IS PROVIDED
JUMPER
BREAKING RESISTOR
(OPTIONAL)
FUSE/NO FUSE BREAKER
R(L1) NFB
R(L1)
MOTOR
U(T1)
S(L2)
S(L2)
V(T2)
T(L3)
T(L3)
W(T3)
IM
3~
FACTORY SETTING:
PNP SOURCE
RA1 (RELAY OUT 1): RUN
RA2 (RELAY OUT 2): FAULT
RA3 (RELAY OUT 3): READY
DCM
COM
FACTORY
SETTING
+24V
+24V
FWD/STOP
REV/STOP
PRESET SPD 1
PRESET SPD 2
PRESET SPD3
PRESET SPD 4
EXT FAULT
FAULT RESET
NA
NA
FWD
REV
MI1
MI2
MI3
MI4
MI5
MI6
MI7
MI8
DIGITAL SIGNAL COMMON TERMINAL WHILE
USING INTERNAL POWER TO RUN SINK MODE
+10V/20mA
3
2
1
0~10V/0~20mA
0-20mA/0~10V
0~+10V
ANALOG SIGNAL
COMMON TERMINAL
MAIN CIRCUIT (POWER)
TERMINALS
MODBUS RS-485
CONTROL
SG+
PIN 1~2, 7, 8:
TERMINALS
RESERVED
SGSHIELDED
PIN 3, 6: GND
LEADS &
PIN 4: SGCABLES
PIN 5: SG+
RA1
250VAC/6A
RB1
30VDC/6A
RC1
RA2
MULTI-FUNCTION OUTPUT
FREQUENCY TERMINALS
250VAC/5A
RC2
30VDC/5A
RA3
DCM
S1
MULTI-FUNCTION OUTPUT
FREQUENCY TERMINALS
250VAC/5A
RC3
30VDC/5A
SCM
+10V
AVI1
ANALOG MULTI-FUNCTION
OUTPUT TERMINAL
0~10V/0~20mA
AFM1
ACI
ACM
AVI2
ACM
AFM2
8 1 8 1
12
ANALOG SIGNAL
COMMON TERMINAL
ANALOG MULTI-FUNCTION
OUTPUT TERMINAL
0~10V/0~20mA
OPTION SLOT 1
COMMUNICATION EXTENSION CARD
OPTION SLOT 3
I/O & RELAY EXTENSION CARD
MOTOR CONTROLS
POWER REMOVAL SAFETY FUNCTION
FOR EMERGENCY STOP
DIGITAL SIGNAL COMMON TERMINAL
5KΩ
MULTI-FUNCTION
OUTPUT TERMINALS
MI: MULTIFUNCTION INPUT
AVI: ANALOG VOLTAGE INPUT
ACI: ANALOG CURRENT INPUT
Frame Sizes A, B, and C
March 2014
WE MAKE IT EASY.
kele.com
888-397-5353 USA
699
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVES
CORE VFD WITH BYPASS
WIRING (continued)
3-PHASE POWER IS PROVIDED
+1/DC+
FRAME E
R
r
S
s
FUSE/NO FUSE BREAKER
R(L1) NFB
S(L2)
T(L3)
T(L3)
COM
+24V
+24V
FWD
REV
MI1
MI2
MI3
MI4
MI5
MI6
MI7
MI8
FWD/STOP
REV/STOP
PRESET SPD 1
PRESET SPD 2
PRESET SPD 3
PRESET SPD 4
EXT FAULT
FAULT RESET
NA
NA
MOTOR CONTROLS
DIGITAL SIGNAL COMMON TERMINAL WHILE
USING INTERNAL POWER TO RUN SINK MODE
POWER REMOVAL SAFETY FUNCTION
FOR EMERGENCY STOP
DIGITAL SIGNAL COMMON TERMINAL
+10V/20mA
3
5KΩ 2
1
0-20mA/0~10V
ANALOG SIGNAL
COMMON TERMINAL
CONTROL
TERMINALS
RA1 (RELAY OUT 1): RUN
RA2 (RELAY OUT 2): FAULT
RA3 (RELAY OUT 3): READY
DCM
S1
MULTI-FUNCTION
OUTPUT TERMINALS
RA1
RB1
30VDC/6A
RA2
250VAC/5A
RC2
RA3
RC3
MULTI-FUNCTION OUTPUT
FREQUENCY TERMINALS
30VDC/5A
MODBUS RS-485
SG+
PIN 1~2, 7, 8:
RESERVED
SGPIN 3, 6: GND
PIN 4: SGPIN 5: SG+
AFM1
ACI
ACM
AVI2
ACM
AFM2
8 1 8 1
30VDC/5A
MULTI-FUNCTION OUTPUT
FREQUENCY TERMINALS
250VAC/5A
SCM
AVI1
250VAC/6A
RC1
+10V
0~10V/0~20mA
0~+10V
MAIN CIRCUIT
(POWER)
TERMINALS
IM
3~
V(T2)
W(T3)
DCM
FACTORY SETTING:
PNP SOURCE
12
MOTOR
R(L1)
S(L2)
FACTORY
SETTING
-/DC+
U(T1)
ANALOG MULTI-FUNCTION
OUTPUT TERMINAL
0~10V/0~20mA
ANALOG SIGNAL
COMMON TERMINAL
ANALOG MULTI-FUNCTION
OUTPUT TERMINAL
0~10V/0~20mA
OPTION SLOT 1
COMMUNICATION EXTENSION CARD
OPTION SLOT 3
I/O & RELAY EXTENSION CARD
SHIELDED
LEADS &
CABLES
MI: MULTIFUNCTION INPUT
AVI: ANALOG VOLTAGE INPUT
ACI: ANALOG CURRENT INPUT
Frame Sizes D and E
700
888-397-5353 USA
kele.com
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVES
CORE VFD WITH BYPASS
WIRING (continued)
BC-3
L1
L2
L3
HVFDSB3
L1
L2
L3
U
V
W
Main Disconnect
Three bypass contactors
shown (BC-1, BC-2, BC-3).
BC-3 not supplied in a two
contactor bypass
BC-1
M
BC-2
Transformer
To factory wired bypass controls
(switches, coils, etc.)
Note: Typical wiring shown. Refer to product installation manual for electrical wiring connections and requirements.
ORDERING INFORMATION
March 2014
DESCRIPTION
CORE VFD W/BYPASS/208V/1 HP/NEMA 1
CORE VFD W/BYPASS/208V/2HP/NEMA 1/FRA
CORE VFD W/BYPASS/208V/3HP/NEMA 1/FRA
CORE VFD W/BYPASS/208V/5HP/NEMA 1/FRA
CORE VFD W/BYPASS/208V/7.5HP/NEMA 1/FRA
CORE VFD W/BYPASS/208V/10HP/NEMA 1/FRB
CORE VFD W/BYPASS/208V/15HP/NEMA 1/FRB
CORE VFD W/BYPASS/208V/20HP/NEMA 1/FRB
CORE VFD W/BYPASS/208V/25HP/NEMA 1/FRC
CORE VFD W/BYPASS/208V/30HP/NEMA 1/FRC
CORE VFD W/BYPASS/208V/40HP/NEMA 1/FRC
CORE VFD W/BYPASS/208V/50HP/NEMA 1/FRD
CORE VFD W/BYPASS/208V/60HP/NEMA 1/FRD
CORE VFD W/BYPASS/208V/75HP/NEMA 1/FRE
CORE VFD W/BYPASS/208V/100HP/NEMA 1/FRE
CORE VFD W/BYPASS/208V/125HP/NEMA 1/FRE
CORE VFD W/BYPASS/230V/1HP/NEMA 1/FRA
CORE VFD W/BYPASS/230V/2HP/NEMA 1/FRA
CORE VFD W/BYPASS/230V/3HP/NEMA 1/FRA
CORE VFD W/BYPASS/230V/5HP/NEMA 1/FRA
CORE VFD W/BYPASS/230V/7.5HP/NEMA 1/FRA
CORE VFD W/BYPASS/230V/10HP/NEMA 1/FRB
CORE VFD W/BYPASS/230V/15HP/NEMA 1/FRB
CORE VFD W/BYPASS/230V/20HP/NEMA 1/FRB
MODEL
HCRBB0250C1300T
HCRBB0300C1300T
HCRBB0400C1300T
HCRBB0500D1300T
HCRBB0600D1300T
HCRBB0750E1300T
HCRBB1000E1300T
HCRBB1250E1300T
HCRBC0010A1300T
HCRBC0020A1300T
HCRBC0030A1300T
HCRBC0050A1300T
HCRBC0075A1300T
HCRBC0100A1300T
HCRBC0150B1300T
HCRBC0200B1300T
HCRBC0250B1300T
HCRBC0300C1300T
HCRBC0400C1300T
HCRBC0500C1300T
HCRBC0600D1300T
HCRBC0750D1300T
HCRBC1000D1300T
HCRBC1250D1300T
WE MAKE IT EASY.
DESCRIPTION
CORE VFD W/BYPASS/230V/25HP/NEMA 1/FRC
CORE VFD W/BYPASS/230V/30HP/NEMA 1/FRC
CORE VFD W/BYPASS/230V/40HP/NEMA 1/FRC
CORE VFD W/BYPASS/230V/50HP/NEMA 1/FRD
CORE VFD W/BYPASS/230V/60HP/NEMA 1/FRD
CORE VFD W/BYPASS/230V/75HP/NEMA 1/FRE
CORE VFD W/BYPASS/230V/100HP/NEMA 1/FRE
CORE VFD W/BYPASS/230V/125HP/NEMA 1/FRE
CORE VFD W/BYPASS/460V/1HP/NEMA 1/FRA
CORE VFD W/BYPASS/460V/2HP/NEMA 1/FRA
CORE VFD W/BYPASS/460V/3HP/NEMA 1/FRA
CORE VFD W/BYPASS/460V/5HP/NEMA 1/FRA
CORE VFD W/BYPASS/460V/7.5HP/NEMA 1/FRA
CORE VFD W/BYPASS/460V/10HP/NEMA 1/FRA
CORE VFD W/BYPASS/460V/15HP/NEMA 1/FRB
CORE VFD W/BYPASS/460V/20HP/NEMA 1/FRB
CORE VFD W/BYPASS/460V/25HP/NEMA 1/FRB
CORE VFD W/BYPASS/460V/30HP/NEMA 1/FRC
CORE VFD W/BYPASS/460V/40HP/NEMA 1/FRC
CORE VFD W/BYPASS/460V/50HP/NEMA 1/FRC
CORE VFD W/BYPASS/460V/60HP/NEMA 1/FRD
CORE VFD W/BYPASS/460V/75HP/NEMA 1/FRD
CORE VFD W/BYPASS/460V/100HP/NEMA 1/FRD
CORE VFD W/BYPASS/460V/125HP/NEMA 1/FRD
kele.com
888-397-5353 USA
12
MOTOR CONTROLS
MODEL
HCRBA0010A1300T
HCRBA0020A1300T
HCRBA0030A1300T
HCRBA0050A1300T
HCRBA0075A1300T
HCRBA0100B1300T
HCRBA0150B1300T
HCRBA0200B1300T
HCRBA0250C1300T
HCRBA0300C1300T
HCRBA0400C1300T
HCRBA0500D1300T
HCRBA0600D1300T
HCRBA0750E1300T
HCRBA1000E1300T
HCRBA1250E1300T
HCRBB0010A1300T
HCRBB0020A1300T
HCRBB0030A1300T
HCRBB0050A1300T
HCRBB0075A1300T
HCRBB0100B1300T
HCRBB0150B1300T
HCRBB0200B1300T
701
NEW!
MOTOR CONTROLS
HONEYWELL COMPACT VARIABLE FREQUENCY DRIVE
SMARTDRIVE COMPACT VFD
DESCRIPTION
This compact VFD is a true micro drive, which saves space
in the equipment cabinet and makes installation easy.
The SmartDrive architecture allows for ease and speed
in drive configuration. The intuitive user interface makes
commissioning a breeze. The SmartDrive Compact VFD
provides a standard PI Controller. Choose options to fit
any application. Interface type, filter, enclosure, inputs, and
outputs are available in a wide array of combinations. For wall
mounting, a frame kit is recommended. Frame kits are not
necessary for installation inside a panel.
FEATURES
• Small, compact micro drive design
• PI controller standard
• No main power supply required for programming
• Intuitive user interface
• DIN rail or screw mounting
• Flexible options include inputs, outputs, field bus, and
filtering
• Application interface "touch wheel" makes
programming easy
CONTROL I/O
SPECIFICATIONS
Supply Voltage MOTOR CONTROLS
12
Motor Rating
Acceleration Time
Deceleration Time
Frequency Range
Digital Switch Inputs
Analog Inputs
Digital Outputs
Analog Output
Relay Outputs
208 to 230 VAC, 1 phase input - 3
phase output
380 to 480 VAC, 3 phase input/
output
0.25 - 7.5 hp
0.1- 3000 seconds
0.1 - 3000 seconds
30 - 320 Hz
6; 0 - 30 VDC programmable
2; (1) 0-10 VDC, (1) 0-20 mA or
4-20 mA
1 Open Collector, max. load 48V/
50mA
1, 0-20 mA or 4-20 mA, RL=500Ω
2; (1) SPST N.O. (1) SPDT 250
VAC/2A, 250 VDC/0.4A Filter Type
RFI
Communication Protocol
RS485 (Modbus protocol), Serial
Operating Humidity
0 to 90% RH (non-condensing)
Operating Temperature14° to 122°F (-10° to 50°C)
Frame Size
MI1, MI2, MI3
Dimensions
Frame sizes
MI1 6.1"H x 2.6"W x 3.9"D
(15.5 x 6.6 x 9.9 cm)
MI2 7.7"H x 3.5"W x 4.0"D
(19.6 x 8.9 x 10.2 cm)
MI3 10.3"D x3.9"W x 4.3"D
(26.2 x 9.9 x 10.9 cm)
Weights
MI1
1.20 lb (0.55 kg)
MI2
1.50 lb (0.65 kg)
MI3
2.18 lb (0.99 kg)
Approvals
CE, UL, cUL FILE #E190898
Warranty
3 years
702
API FULL
Signal
Terminal
1 +10Vre Ref. voltage out
Analog signal in 1
2 AI1
888-397-5353 USA
kele.com
mA
3
6
GND
24Vout
I/O signal ground
24V output for DI's
7
8
GND
DI1
I/O signal ground
Digital input 1
9
10
A
B
4
DI2
Digital input 2
DI3
Digital input 3
A
B
AI2
RS485 signal A
RS485 signal B
Analog signal in 2
5
13
14
15
16
18
GND
GND
DI4
I/O signal ground
I/O signal ground
Digital input 4
DI5
Digital input 5
DI6
Digital input 6
AO
20 DO
22 RO 11
23 RO 12
24 RO 21
25 RO 22
26 RO 23
Digital signal out
Relay out 1
Factory preset
Freq. reference P)
Description
Maximum load 10 mA
0 - +10 V Ri = 200 kΩ
(min)
±20%, max. load 50 mA
Start forward P)
Start reverse P)
0 - +30 V Ri = 12 kΩ min
Preset speed B0 P)
FB Communication
FB Communication
PI actual value P)
0(4) - 20 mA, Ri = 200Ω
Preset speed B1P)
0 - +30 V Ri = 12 kΩ (min)
Fault reset P)
Disable PI contr. P)
Output frequency P)
Active = READY P)
Active = RUN P)
Relay out 2 Active = FAULT P)
0(4) - 20 mA, RL = 500Ω
Open collector, max. load
48V/50mA
Max. switching load:
250 VAC/2A or 250 VDC/
0.4A
Max. switching load:
250 VAC/2A or 250 VDC/
0.4A
P) = Programmable function, see parameter lists and descriptions in installation manual.
Note: NEMA 1 frame kits include the top protection from
vertically dripping water with additional physical contact
protection over the wiring terminals. Recommended for nonenclosed VFD mounting.
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
HONEYWELL COMPACT VARIABLE FREQUENCY DRIVE
SMARTDRIVE COMPACT VFD
ORDERING INFORMATION
Limited IO Model
Supply Voltage
Current
Rating
Horsepower
EMC
Frame
Size
HVFDCD1B0003F00
HVFDCD1B0003L00
208 to 230 VAC, 1 phase input - 3 phase output
1.7A
0.25
NO
MI1
HVFDCD1B0003F01
HVFDCD1B0003L01
208 to 230 VAC, 1 phase input - 3 phase output
1.7A
0.25
YES
MI1
HVFDCD1B0005F00
HVFDCD1B0005L00
208 to 230 VAC, 1 phase input - 3 phase output
2.4A
0.5
NO
MI1
HVFDCD1B0005F01
HVFDCD1B0005L01
208 to 230 VAC, 1 phase input - 3 phase output
2.4A
0.5
YES
MI1
HVFDCD1B0007F00
HVFDCD1B0007L00
208 to 230 VAC, 1 phase input - 3 phase output
2.8A
0.75
NO
MI1
HVFDCD1B0007F01
HVFDCD1B0007L01
208 to 230 VAC, 1 phase input - 3 phase output
2.8A
0.75
YES
MI1
HVFDCD1B0010F00
HVFDCD1B0010L00
208 to 230 VAC, 1 phase input - 3 phase output
3.7A
1
NO
MI1
HVFDCD1B0010F01
HVFDCD1B0010L01
208 to 230 VAC, 1 phase input - 3 phase output
3.7A
1
YES
MI1
HVFDCD1B0015F00
HVFDCD1B0015L00
208 to 230 VAC, 1 phase input - 3 phase output
4.8A
1.5
NO
MI2
HVFDCD1B0015F01
HVFDCD1B0015L01
208 to 230 VAC, 1 phase input - 3 phase output
4.8A
1.5
YES
MI2
HVFDCD1B0020F00
HVFDCD1B0020L00
208 to 230 VAC, 1 phase input - 3 phase output
7.0A
2
NO
MI2
HVFDCD1B0020F01
HVFDCD1B0020L01
208 to 230 VAC, 1 phase input - 3 phase output
7.0A
2
YES
MI2
HVFDCD1B0030F00
HVFDCD1B0030L00
208 to 230 VAC, 1 phase input - 3 phase output
11.0A
3
NO
MI3
HVFDCD1B0030F01
HVFDCD1B0030L01
208 to 230 VAC, 1 phase input - 3 phase output
11.0A
3
YES
MI3
HVFDCD3C0005F00
HVFDCD3C0005L00
380 to 480 VAC, 3 phase input/ output
1.3A
0.5
NO
MI1
HVFDCD3C0005F01
HVFDCD3C0005L01
380 to 480 VAC, 3 phase input/ output
1.3A
0.5
YES
MI1
HVFDCD3C0007F00
HVFDCD3C0007L00
380 to 480 VAC, 3 phase input/ output
1.9A
0.75
NO
MI1
HVFDCD3C0007F01
HVFDCD3C0007L01
380 to 480 VAC, 3 phase input/ output
1.9A
0.75
YES
MI1
HVFDCD3C0010F00
HVFDCD3C0010L00
380 to 480 VAC, 3 phase input/ output
2.4A
1
NO
MI1
HVFDCD3C0010F01
HVFDCD3C0010L01
380 to 480 VAC, 3 phase input/ output
2.4A
1
YES
MI1
HVFDCD3C0015F00
HVFDCD3C0015L00
380 to 480 VAC, 3 phase input/ output
3.3A
1.5
NO
MI1
HVFDCD3C0015F01
HVFDCD3C0015L01
380 to 480 VAC, 3 phase input/ output
3.3A
1.5
YES
MI1
HVFDCD3C0020F00
HVFDCD3C0020L00
380 to 480 VAC, 3 phase input/ output
4.3A
2
NO
MI2
HVFDCD3C0020F01
HVFDCD3C0020L01
380 to 480 VAC, 3 phase input/ output
4.3A
2
YES
MI2
HVFDCD3C0030F00
HVFDCD3C0030L00
380 to 480 VAC, 3 phase input/ output
5.6A
3
NO
MI2
HVFDCD3C0030F01
HVFDCD3C0030L01
380 to 480 VAC, 3 phase input/ output
5.6A
3
YES
MI2
HVFDCD3C0040F00
HVFDCD3C0040L00
380 to 480 VAC, 3 phase input/ output
7.6A
4
NO
MI3
HVFDCD3C0040F01
HVFDCD3C0040L01
460 to 480 VAC, 3 phase input/ output
7.6A
4
YES
MI3
HVFDCD3C0050F00
HVFDCD3C0050L00
460 to 480 VAC, 3 phase input/ output
9.0A
5
NO
MI3
HVFDCD3C0050F01
HVFDCD3C0050L01
460 to 480 VAC, 3 phase input/ output
9.0A
5
YES
MI3
HVFDCD3C0075F00
HVFDCD3C0075L00
460 to 480 VAC, 3 phase input/ output
12.0A
7.5
NO
MI3
HVFDCD3C0075F01
HVFDCD3C0075L01
460 to 480 VAC, 3 phase input/ output
12.0A
7.5
YES
MI3
March 2014
12
MOTOR CONTROLS
Full IO Model
ACCESSORIES
HVFDCABLE
HVFDCDMCA
HVFDCDMCAKIT
HVFDCDNEMA1FR1
HVFDCDNEMA1FR2
HVFDCDNEMA1FR3
Commissioning cable and USB adaptor
VFD commissioning device
Commisioning kit
Enclosure upgrade Nema 1 kit frame size1
Enclosure upgrade Nema 1 kit frame size2
Enclosure upgrade Nema 1 kit frame size3
WE MAKE IT EASY.
kele.com
888-397-5353 USA
703
NEW!
MOTOR CONTROLS
HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVES
SMARTVFD HVAC
DESCRIPTION
SmartVFD HVAC drives are all-purpose, and can handle
both constant-torque and variable-torque loads. The
firmware includes special features that make start-up and
commissioning of HVAC applications especially easy.
Application-specific startup wizards for pumps and fans,
combined with the simple and intuitive user interface, make
the SmartVFD a pleasure rather than a chore. Integration
is a snap with the SmartVFD. It includes both Ethernet and
RS485 connections, and will talk BACnet, Modbus, and JCI
N2. Take the complexity out of drive selection, installation,
and startup - choose SmartVFD for your HVAC projects and
start saving time, money, and manpower as well as energy.
FEATURES
•
•
•
•
•
•
•
MOTOR CONTROLS
12
Intuitive commissioning
High resolution graphic interface
User manual included in firmware
Simple start-up wizard - pump or fan
Fire mode
2 PID controllers
Real-time clock
STANDARD I/O BOARD
SPECIFICATIONS
Supply Voltage
Model specific, 3 phase, 60 Hz,
380-480 VAC or 200-240 VAC
Motor Rating
0.75 to 250 Hp
Frequency Range
0-320 Hz
Acceleration Time
0.1 - 3000 seconds
Deceleration Time
0.1 - 3000 seconds
Digital Inputs
6 logical, 24 VDC= on, 0 VDC= off,
all configurable
Analog Input
2; 0-10V or 4-20 mA voltage
input impedance 200Ω k
current impedance 250Ω
Digital Output
Open collector,
max. load 48V/ 50 mA
Analog Output
1; 0-10 VDC or 4-20 mA
programmable
500Ω maximum load
Relay Outputs
2; SPDT 8A at 24 VDC or 250 VAC
0.4A at 125 VDC minimum load
10mA at 5 VAC/VDC
Filter Type
5% DC choke
Class 2 GMC/ RFI
EMC
Complies with EN50082-1, -2
EN61800-3
Communication Protocol
RS485
JCI N2, MODBUS, BACnet MS/TP
Ethernet
BACnet/ IP, Modbus/TCP
Operating Humidity
0 to 95% RH (non-condensing)
Operating Temperature14° to 104°F (-10° to 40°C)
Approvals
UL Listed File E190898 CE RoHS
Eco Friendly
Yes
Warranty
3 years
704
888-397-5353 USA
kele.com
Terminal
Signal
1
Reference output
+10 VDC, +3%; Maximum current 10 mA
2
Analog input,
voltage or current
Analog input channel 1; Short-circuited protected
0- +10VDC (Ri = 200 kΩ)
4-20 mA (Ri = 250 Ω)
Resolution 0.1%, accuracy ±1%
Selection V/mA with dip-switches
3
Analog input
common (current)
Differential input if not connected to ground;
Allows ±20V differential mode voltage to GND
4
Analog input
voltage or current
Analog input channel 2; Short-circuited protected
Default: 4-20 mA (Ri =250 Ω)
0-10 VDC (Ri = 200kΩ)
Resolution 0.1%, accuracy ±1%
Selection V/mA with dip-switches
5
Analog input
common (current)
Differential input if not connected to ground;
Allows 20V differential mode voltage to GND
6
+24 VDC, ±10%, max volt. ripple < 100mVrms; max. 250mA
24VDC aux. voltage Dimensioning: max. 1000mA/control unit.
Short-circuit protected
7
I/O ground
8
Digital input 1
9
Digital input 2
10
Digital input 3
11
Common A for
DIN1-DIN6
12
Technical information
Ground for reference and controls (connected internally to
frame earth through 1MΩ)
Positive or negative logic
Ri = min. 5kΩ
0...5VDC = “0”
15…30VDC = “1”
Digital inputs can be disconnected from ground
+24 VDC, ±10%, max volt. ripple < 100mVrms; max. 250mA
24 VDC aux. voltage Dimensioning: max. 1000mA/control unit.
Short-circuit protected
13
I/O ground
14
Digital input 4
15
Digital input 5
16
Digital input 6
17
Common A for
DIN1-DIN6
18
Analog signal
(+output)
19
Analog output
common
30
24 VDC auxiliary
input voltage
A
RS485
B
RS485
Ground for reference and controls (connected internally to
frame earth through 1MΩ)
Positive or negative logic
Ri = min. 5kΩ
0...5VDC = “0”
15…30VDC = “1”
Digital inputs can be isolated from ground.
Analog output channel 1, selection 0 -20mA, load <500Ω
Default: 0-20 mA/0-10 VDC
Resolution 0.1%, accuracy ±2%
Selection V/mA with dip-switches
Short-circuited protected.
Can be used as external power backup for the control unit
Differential receiver/transmitter
Set bus termination with dip switches
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVES
SMARTVFD HVAC
RELAY BOARD TECHNICAL INFORMATION
Relay board with two change-over
contact (SPDT) relays and one relay
Relay with normally-open (NO or SPST)
board contact.
5.5 mm isolation between channels.
21
22
23
24
25
26
28
29
RELAY CONNECTIONS
From
Standard I/O board
From term.
#12
Relay
Board
From term.
#13
RUN
Terminal
21 RO1/1
Signal
Relay output 1
22 RO1/2
23 RO1/3
Switching capacity 2 4VDC/8A
250 VAC/8A
Relay
Output 1* 125 VDC/0.4A
Min.switching load 5V/10mA
24 RO2/1
Relay output 2
25 RO2/2
26 RO2/3
Switching capacity 24 VDC/8A
250 VAC/8A
Relay
Output 2* 125 VDC/0.4A
Min.switching load 5V/10mA
28 TI1+
29 TI1-
Thermistor input
Thermistor Rtrip = 4.7 kΩ (PTC);
Input
Measuring voltage 3.5V
* If 230VAC is used as control voltage from the
output relays, the control circuitry must be
powered with a separate isolation transformer
to limit short circuit current and ovrvoltage
spikes. This is to prevent welding on the relay
contacts. Refer to standard EN 60204-1,
section 7.2.9
12
DIMENSIONS AND WEIGHTS
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
March 2014
208/ 230 VAC
460 VAC
Enclosure
NEMA type
Width
in. (cm)
Height
in. (cm)
Depth
in. (cm)
Weight
lb (kg)
0.75-4 HP
0.75-4 HP
0.75-4 HP
5-10 Hp
5-10 Hp
5-10 Hp
15-20 Hp
15-20 Hp
15-20 Hp
25-40 Hp
25-40 Hp
25-40 Hp
50-75 Hp
50-75 Hp
50-75 Hp
100-125 Hp
100-125 Hp
1.5-7.5 HP
1.5-7.5 HP
1.5-7.5 HP
10-20 Hp
10-20 Hp
10-20 Hp
25-40 Hp
25-40 Hp
25-40 Hp
50-75 Hp
50-75 Hp
50-75 Hp
100-150 Hp
100-150 Hp
100-150 Hp
200-250 Hp
200-250 Hp
1
12
3
1
12
3
1
12
3
1
12
3
1
12
3
1
12
5 (12.7)
5 (12.7)
20.5 (52.07)
5.7 (14.48)
5.7 (14.48)
20.5 (52.07)
7.7 (19.56)
7.7 (19.56)
28.5 (72.39)
9.3 (23.62)
9.3 (23.62)
28.8 (73.15)
11.4 (28.96)
11.4 (28.96)
11.4 (28.96)
18.9 (48.00)
18.9 (48.00)
12.9 (32.77)
12.9 (32.77)
20 (50.8)
16.5 (41.91)
16.5 (41.91)
24 (60.96)
21.9 (55.63)
21.9 (55.63)
36 (88.9)
25.4 (64.51)
25.4 (64.51)
48 (121.92)
38 (96.52)
38 (96.52)
38 (96.52)
45.3 (115.06)
45.3 (115.06)
7.5 (19.05)
7.5 (19.05)
10 (25.4)
8.4 (21.34)
8.4 (21.34)
10 (25.4)
9 (22.86)
9 (22.86)
10 (25.4)
10.2 (25.91)
10.2 (25.91)
12 (30.48)
13.5 (34.29)
13.5 (34.29)
13.5 (34.29)
14.4 (36.58)
14.4 (36.58)
13.0 (5.9)
13.0 (5.9)
13.0 (5.9)
22.0 (10.0)
22.0 (10.0)
22.0 (10.0)
44.0 (20.0)
44.0 (20.0)
44.0 (20.0)
83.0 (37.7)
83.0 (37.7)
83.0 (37.7)
154.0 (70.0)
154.0 (70.0)
154.0 (70.0)
238.0 (108.2)
238.0 (108.2)
WE MAKE IT EASY.
kele.com
888-397-5353 USA
MOTOR CONTROLS
Frame
705
NEW!
MOTOR CONTROLS
HONEYWELL ALL PURPOSE VARIABLE FREQUENCY DRIVES
SMARTVFD HVAC
ORDERING INFORMATION
HP
MOTOR CONTROLS
12
Amps
460 VAC
3.4
1.5
4.8
2
5.6
3
8
4
9.6
5
12
7.5
16
10
23
15
31
20
38
25
46
30
61
40
72
50
87
60
105
75
140
100
170
125
205
150
261
200
310
250
208/ 230 VAC
3.7
0.75
4.8
1
6.6
1.5
8
2
11
3
18
5
24
7.5
31
10
48
15
62
20
75
25
88
30
105
40
140
50
170
60
205
75
261
100
310
125
Frame
NEMA 1
4
HVFDSD3C0015G100
4
HVFDSD3C0020G100
4
HVFDSD3C0030G100
4
HVFDSD3C0040G100
4
4
NEMA 12
NEMA3R
HVFDSD3C0015G200
HVFDSD3C0015G300
HVFDSD3C0020G200
HVFDSD3C0020G300
HVFDSD3C0030G200
HVFDSD3C0030G300
HVFDSD3C0040G200
HVFDSD3C0040G300
HVFDSD3C0050G100
HVFDSD3C0050G200
HVFDSD3C0050G300
HVFDSD3C0075G100
HVFDSD3C0075G200
HVFDSD3C0075G300
5
HVFDSD3C0100G100
HVFDSD3C0100G200
HVFDSD3C0100G300
5
HVFDSD3C0150G100
HVFDSD3C0150G200
HVFDSD3C0150G300
5
HVFDSD3C0200G100
HVFDSD3C0200G200
HVFDSD3C0200G300
6
HVFDSD3C0250G100
HVFDSD3C0250G200
HVFDSD3C0250G300
6
HVFDSD3C0300G100
HVFDSD3C0300G200
HVFDSD3C0300G300
6
HVFDSD3C0400G100
HVFDSD3C0400G200
HVFDSD3C0400G300
7
HVFDSD3C0500G100
HVFDSD3C0500G200
HVFDSD3C0500G300
7
HVFDSD3C0600G100
HVFDSD3C0600G200
HVFDSD3C0600G300
7
HVFDSD3C0750G100
HVFDSD3C0750G200
HVFDSD3C0750G300
8
HVFDSD3C1000G100
HVFDSD3C1000G200
HVFDSD3C1000G300
8
HVFDSD3C1250G100
HVFDSD3C1250G200
HVFDSD3C1250G300
8
HVFDSD3C1500G100
HVFDSD3C1500G200
HVFDSD3C1500G300
9
HVFDSD3C2000G100
HVFDSD3C2000G200
-
9
HVFDSD3C2500G100
HVFDSD3C2500G200
-
4
HVFDSD3A0007G100
HVFDSD3A0007G200
HVFDSD3A0007G300
4
HVFDSD3A0010G100
HVFDSD3A0010G200
HVFDSD3A0010G300
4
HVFDSD3A0015G100
HVFDSD3A0015G200
HVFDSD3A0015G300
4
HVFDSD3A0020G100
HVFDSD3A0020G200
HVFDSD3A0020G300
4
HVFDSD3A0030G100
HVFDSD3A0030G200
HVFDSD3A0030G300
5
HVFDSD3A0050G100
HVFDSD3A0050G200
HVFDSD3A0050G300
5
HVFDSD3A0075G100
HVFDSD3A0075G200
HVFDSD3A0075G300
5
HVFDSD3A0100G100
HVFDSD3A0100G200
HVFDSD3A0100G300
6
HVFDSD3A0150G100
HVFDSD3A0150G200
HVFDSD3A0150G300
6
HVFDSD3A0200G100
HVFDSD3A0200G200
HVFDSD3A0200G300
7
HVFDSD3A0250G100
HVFDSD3A0250G200
HVFDSD3A0250G300
7
HVFDSD3A0300G100
HVFDSD3A0300G200
HVFDSD3A0300G300
7
HVFDSD3A0400G100
HVFDSD3A0400G200
HVFDSD3A0400G300
8
HVFDSD3A0500G100
HVFDSD3A0500G200
HVFDSD3A0500G300
8
HVFDSD3A0600G100
HVFDSD3A0600G200
HVFDSD3A0600G300
8
HVFDSD3A0750G100
HVFDSD3A0750G200
HVFDSD3A0750G300
9
HVFDSD3A1000G100
HVFDSD3A1000G200
-
9
HVFDSD3A1250G100
HVFDSD3A1250G200
-
Drives are typically sized to match the horsepower rating of the motor, which will be accurate 95 percent of the time. For greatest accuracy, drives
should be sized based upon the Full Load Amps or current draw of the motor. The VFD must have a slightly larger current rating maximum.
32006630-001
HVFDCABLE
706
888-397-5353 USA
kele.com
ACCESSORIES
LON communication card
Commissioning cable and USB adaptor
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASS
SMARTVFD HVAC WITH BYPASS ASSEMBLY
DESCRIPTION
Honeywell’s integral bypass and disconnect system make
applying the SmartVFD drive a snap. Available with a simple
fused disconnect switch, a 2-contactor bypass assembly, or
a 3-contactor bypass assembly, it simplifies installation. All
the features of the SmartVFD are included -- a wide array
of configurable inputs and outputs, and all the most popular
network protocols, and the super easy startup wizards that
speed commissioning. All drives feature Hand-Off-Auto
operation as a is fully integrated keypad function. Make the
SmartVFD choice for your variable speed drive needs.
FEATURES
•
•
•
•
•
•
•
•
•
Disconnect, 2-, or 3-contactor bypass
Fused disconnect
Auto bypass available
Available in NEMA 1, 12, or 3R enclosure types
Compact size
SmartVFD wizard for pump or fan control
Intuitive commissioning
High resolution graphic interface
User manual built in to firmware
SPECIFICATIONS
Analog Output
208 VAC, 3 phase, 60 Hz
230 VAC, 3 phase, 60 Hz
480 VAC, 3 phase, 60Hz
1.0 to 250 Hp
0 - 320 Hz
0.1 - 3000 seconds
0.1 - 3000 seconds
6 factory preset
2; 0-10V or 4-20 mA programmable
Open collector,
max. load 48V / 50 mA
1; 4-20 mA
Relay Outputs
2 each SPDT 8A at 24 VDC or
250 VAC 0.4A at 125 VDC Minimum
load 10Ma at 5 VAC/VDC
Filter Type
5% DC choke , and class 2 GMC/RFI
EMC
Complies with EN50082-1, -2
Communication Protocol
RS485
BACnet MS/TP, N2, Modbus
Ethernet
BACnet/ IP, Modbus/TCP
Operating Humidity
0 to 95% RH (non-condensing)
Operating Temperature14° to 104°F (-10° to 40°C)
Approvals
UL Listed File #E190898 cUL CE
RoHS
Eco Friendly
Yes
Warranty
3 years
WIRING
BC-3
L1
L2
L3
L1
L2
L3
Main Disconnect
Three bypass contactors
shown (BC-1, BC-2, BC-3).
BC-3 not supplied in a two
contactor bypass
HVFDSB3
12
MOTOR CONTROLS
Supply Voltage
Motor Rating
Frequency Range
Acceleration Time
Deceleration Time
Digital Inputs
Analog Input
Digital Output
BC-1
U
V
W
M
BC-2
Transformer
To factory wired bypass controls
(switches, coils, etc.)
Note: Typical wiring shown. Refer to product installation manual for electrical wiring connections and requirements.
March 2014
WE MAKE IT EASY.
kele.com
888-397-5353 USA
707
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASS
SMARTVFD HVAC WITH BYPASS ASSEMBLY
DIMENSIONS - IN (CM)
Horsepower and
Voltage
Frame 208/ 230
460 VAC
Size
VAC
4
5
6
7
0.75-4 Hp
5-10Hp
NEMA 1
Configuration
Width
Height
Disconnect
8.9 (22.6)
8.9 (22.6)
2-Contactor
8.9 (22.6)
8.9 (22.6)
3-Contactor,
3-Contactor
w/ Auto- Bypass
8.9 (22.6)
Disconnect
1.5-7.5 Hp
10-20 Hp
15-20Hp
25-40 Hp
25-40Hp
50-75 Hp
12
MOTOR CONTROLS
8
50-75 Hp
100-150 Hp
NEMA 12
NEMA 3 R
Depth
Width
Height
Depth
Width
Height
Depth
10.7 (26.2)
12.0 (29.4)
36.0 (88.2)
8.8 (21.6)
20.5 (50.2)
20.0 (49.0)
10.0 (24.5)
10.7 (26.2)
16.0 (39.2)
36.0 (88.2)
8.8 (21.6)
24.5 (60.0)
24.0 (58.8)
10.0 (24.5)
8.9 (22.6)
10.7 (26.2)
16.0 (39.2)
36.0 (88.2)
8.8 (21.6)
24.5 (60.0)
24.0 (58.8)
10.0 (24.5)
8.9 (22.6)
34.5 (84.5)
10.7 (26.2)
12.0 (29.4)
40.0 (98)
8.8 (21.6)
24.5 (60.0)
24.0 (58.8)
10.0 (24.5)
2-Contactor
8.9 (22.6)
34.5 (84.5)
10.7 (26.2)
16.0 (39.2)
44.0 (107.8)
8.8 (21.6)
28.5 (69.8)
30.0 (73.5)
10.0 (24.5)
3-Contactor,
3-Contactor
w/ Auto- Bypass
8.9 (22.6)
41.5 (101.7)
10.7 (26.2)
16.0 (39.2)
44.0 (107.8)
8.8 (21.6)
28.5 (69.8)
30.0 (73.5)
10.0 (24.5)
Disconnect
12.4 (30.4)
45.0 (110.3)
12.6 (30.9)
16.0 (39.2)
46.0 (112.7) 10.8 (26.5) 28.5 (69.8)
36.0 (88.2)
10.0 (24.5)
2-Contactor
12.4 (30.4)
45.0 (110.3)
12.6 (30.9)
20.0 (49.0)
54.0 (132.3) 10.8 (26.5) 34.5 (84.5)
36.0 (88.2)
10.0 (24.5)
3-Contactor,
3-Contactor
w/ Auto- Bypass
12.4 (30.4)
55.0 (134.8)
12.6 (30.9)
20.0 (49.0)
54.0 (132.3) 10.8 (26.5) 34.5 (84.5)
36.0 (88.2)
10.0 (24.5)
Disconnect
20.84 (51.1)
51.5 (126.2)
11.4 (27.9)
16.0 (39.2)
50.0 (122.5) 11.8 (28.9) 28.5 (69.8) 48.0 (117.6) 12.0 (29.4)
2-Contactor
20.84 (51.1)
51.5 (126.2)
11.4 (27.9)
24.0 (58.8)
64.0 (156.8) 13.6 (33.3) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4)
3-Contactor,
3-Contactor
w/ Auto- Bypass
20.84 (51.1)
59.0 (144.6)
11.4 (27.9)
24.0 (58.8)
64.0 (156.8) 13.6 (33.3) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4)
Disconnect
25.0 (61.3)
60.0 (147.0)
16.2 (39.7)
20.0 (49.0)
64.0 (156.8) 15.1 (36.9) 40.4 (98.9) 48.0 (117.6) 12.0 (29.4)
2-Contactor
25.0 (61.3)
60.0 (147.0)
16.2 (39.7)
56.0 (137.2) 48.0 (117.6) 15.1 (36.9) 40.4 (98.9) 60.0 (147.0) 12.0 (29.4)
3-Contactor,
3-Contactor
w/ Auto- Bypass
25.0 (61.3)
70.0 (171.5)
16.2 (39.7)
56.0 (137.2) 48.0 (117.6) 15.1 (36.9) 40.4 (98.9) 60.0 (147.0) 12.0 (29.4)
SMART VFD BYPASS CONFIGURATIONS
Our five configurations make it easy for you to select the right bypass to complete your drive package. All bundles are available in
NEMA 1, NEMA 12 and ventilated NEMA 3R HOA (HAND OFF AUTO).
SmartVFD Disconnect Only
• Adds a fused disconnect to the VFD.
SmartVFD 2-Contactor Bypass
Provides an economical means of bypassing the VFD.
• Freeze/Fire/Smoke Interlock
SmartVFD 3-Contactor Bypass
Commission, service or replace the VFD without affecting the
operation of the motor.
• Fused Disconnect
• Freeze/Fire/Smoke Interlock
• VFD is isolated from power with motor running in BYPASS
mode
• TEST position powers the VFD without sending power to the
motor
708
888-397-5353 USA
kele.com
SmartVFD 3-Contactor Bypass with Auto-Bypass
The package adds the control capabilities below to the
standard three contactor bypass.
• Any VFD fault will automatically send the bypass to BYPASS
mode
• A contact closure sends the bypass to BYPASS mode
• Dry contacts indicate when the bypass is in BYPASS mode,
alerting the building management system
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
HONEYWELL VARIABLE FREQUENCY DRIVE WITH BYPASS
SMARTVFD HVAC WITH BYPASS ASSEMBLY
ORDERING INFORMATION
HVFDSB3
Honeywell SmartVFD HVAC
A
208 VAC - up to 75 Hp
B
230 VAC - up to 75 Hp
C
480 VAC - up to 150 Hp
Motor Horsepower
0007
.75 Hp
208, 230 & 480 VAC
0010
1 Hp
208, 230 & 480 VAC
0015
1.5 Hp
208, 230 & 480 VAC
0020
2 Hp
208, 230 & 480 VAC
0030
3 Hp
208, 230 & 480 VAC
0040
4 Hp
208, 230 & 480 VAC
0050
5 Hp
208, 230 & 480 VAC
0075
7.5 Hp
208, 230 & 480 VAC
0100
10 Hp
208, 230 & 480 VAC
0150
15 Hp
208, 230 & 480 VAC
0200
20 Hp
208, 230 & 480 VAC
0250
25 Hp
208, 230 & 480 VAC
0300
30 Hp
208, 230 & 480 VAC
0400
40 Hp
208, 230 & 480 VAC
0500
50 Hp
208, 230 & 480 VAC
0600
60 Hp
208, 230 & 480 VAC
0750
75 Hp
208, 230 & 480 VAC
1000
100 Hp
480 VAC
1250
125 Hp
480 VAC
1500
150 Hp
480 VAC
12
User Interface
Graphic User Interface
MOTOR CONTROLS
G
Enclosure
1
NEMA 1
2
NEMA 12
3
NEMA 3R
Options
HVFDSB3
C
0400
32006630-001
HVFDCABLE
March 2014
G
1
10
Disconnect only
20
Drive with 2 contractor BYPASS
30
Drive with 3 contactor BYPASS
31
Drive with 3 contactor BYPASS, w/ Fused disconnect and Auto-bypass
30
Example: HVDSB3C0400G130 480 VAC, 40 Hp, Smart VFD NEMA 1
with graphic keypad display, 3 contractor bypass
ACCESSORIESPAGE
LON communication card
Commissioning cable and USB adaptor
WE MAKE IT EASY.
kele.com
888-397-5353 USA
709
NEW!
MOTOR CONTROLS
MOTOR CONTROL ACRONYMS, CALCULATIONS & CONVERSION FORMULAS
IGBT = insulated gate bi-thermal thyristor
AC = alternating current
ANSI = American National Standards Institute
LCI = load-commutated inverter
ASD = adjustable speed drive
NEMA = National Electrical Manufacturers Association
BHP = brake horsepower
CFM = cubic feet per minute
MOTOR CONTROLS
12
IEEE = Institute of Electrical and Electronics Engineers
NPV = net present value
CSA = Canadian Standards Association
PAM = pulse amplitude modulation
CSI = current source inverter
PLC = programmable logic controller
DC = direct current
PWM = pulse width modulated (inverter)
DSP = digital signal processor
SCR = silicon-controlled rectifier
ECC = eddy current coupling
SR = switched reluctance
FPM = feet per minute
THD = total harmonic distortion
GPM = gallon per minute
V = voltage
GTO = gate turnoff (thyristor)
VSI = variable source inverter
HDF = harmonic distortion factor
VVI = variable voltage inverter
Calculating the Horsepower Requirement
of a Load
The mechanical load required by the driven equipment is
known as the Brake Horsepower (BHP). The BHP value
can be calculated by the following:
BHP = T x N (required HP)
5,250
Where:
HP = horsepower supplied by the motor
T = Torque (lb-ft) force x radius
N = base speed of motor (rpm)
Once the machine BHP (speed times torque) requirement is
determined, horsepower (HP) can be calculated:
Rated motor HP = Motor Efficiency (%) / 100 = available HP
If the calculated horsepower falls between standard
available motor ratings, select the higher available
horsepower rating. It is good practice to allow some margin
when selecting the motor horsepower.
710
888-397-5353 USA
kele.com
CONVERSION FORMULAS/FACTORS
Multiply
By
To Obtain
Meters
3.281
Feet
Meters
39.37
Inches
Inches
0.025
Meters
Feet
0.305
Meters
Torque
Newton-Meters
0.738
lb-ft
lb-ft
1.356
Newton-Meters
lb-in
0.083
lb-ft
lb-ft
12.00
lb-in
Rotation
RPM
6.00
Degrees per second
RPM
0.105
Radius per second
Degrees per second
0.167
RPM
Radius per second
9.549
RPM
Power
Watts
0.001
HP
lb-ft per minute
0.000
HP
HP
746
Watts
HP
30300
lb-ft/min
Temperature Degrees C = (Degrees F-32) x 5/9
Degrees F = (Degrees C x 9/5) + 32
Length
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.
March 2014
NEW!
MOTOR CONTROLS
GLOSSARY OF COMMON TERMS
Alternating Current: The flow of electricity which changes direction on a regular continuous cycle reaching a
maximum in one direction, decreasing to zero, then reversing to reach a maximum in the opposite direction.
Air Gap: The space between the rotating and stationary part of an electric motor. Magnetic energy is transferred
across this gap.
Ambient: The air which surrounds a motor for air cooled machines.
Ampere: A unit of current which is a measure of the rate of electron flow. It is often abbreviated as Amp. The
unit of current flow is the amp.
Breakdown Torque: The maximum torque that a motor can develop at rated voltage without stalling or an
abrupt drop in speed.
Brush: A current carrying material which is in contact with an armature or slip ring assembly to provide an electrical connection between rotating and stationary components of a motor. Capacitor: A device which can store
electrical charge. In an AC circuit, a capacitor causes the voltage to lead the current. The unit of capacitance is
the Farad.
Commutator: An assembly which is mounted on the shaft of a DC motor to provide the switching functions
between the armature coils and the power supply.
Conductor: Any material which offers little resistance to the flow of electricity such as copper.
Duty Cycle: The relationship between the operating time and the resting time of an electric motor.
Eddy Current: Localized currents in electrical steels that are caused by alternating magnetic flux resulting in
losses and heating.
12
Efficiency: The ratio of mechanical output to the electrical input power of a motor.
Field: The term used to describe the stationary part of a DC machine. The field provides the magnetic flux which
interacts with the armature.
Flux: The magnetic field which is established around a current carrying conductor or a permanent magnet.
Frequency: The rate at which alternating current reverses its direction of flow. The unit of frequency is either
Hertz or cycles per second.
MOTOR CONTROLS
Electromotive Force (emf): A synonym for voltage usually used to describe induced or generated voltages in
an electric circuit.
Full Load Current: The current that a motor draws at rated voltage, frequency and load.
Full Load Slip: The difference between the synchronous speed of a motor and full load speed. It is often expressed as a ratio of the synchronous speed to full load speed in percent.
Full Load Speed: The speed of the motor at rated voltage, frequency and load.
Full Load Torque: The torque that is necessary to produce rated horsepower at full load speed.
Horsepower: A measurement of power used to rate electric motors. The unit of power rating in motors is either
horsepower or kilowatts. One horsepower is equal to 746 watts.
March 2014
WE MAKE IT EASY.
kele.com
888-397-5353 USA
711
NEW!
MOTOR CONTROLS
GLOSSARY OF COMMON TERMS
Impedance: The total opposition a circuit offers to the flow of alternating current. It is the vector sum of resistance and reactance.
Inductance: The property of an electrical circuit which opposes a change in current due to the magnetic field
induced by that current.
Inertia: Inertia is the resistance an object has to a change in its state of motion. It is determined by the weight of
the object multiplied by the square of the radius of gyration (k). Rotating parts do not operate at the same speed,
therefore calculating the inertia for each moving part allows rotating parts to be considered as a single unit working together.
Line Voltage: The voltage supplied to the input terminals of an electric device.
Magnetomotive Force (mmf): The magnetic energy supplied in the establishment of magnetic flux. It is analogous to the electromotive force in an electric circuit.
Phase: A term used to describe the spatial relationship of windings in an electric motor or voltages and currents
in an electric circuit.
Power Factor: A measurement of the difference in phase between voltage and current in an electric circuit.
Most electrical devices cause the current to lag the voltage because of inductance. The voltage leads the current in capacitive circuits.
Reactance (inductive): The property of a magnetic circuit which causes the voltage to lag the current.
12
Resistance: The property of an electrical conductor which impedes the flow of electricity. The unit of resistance
is the ohm.
MOTOR CONTROLS
Rotor: The rotating member of an electric motor.
Service Factor: The service factor of an AC motor is a multiplier which when applied to the rated horsepower
indicates the permissible loading which may be carried under the conditions specified for the service factor.
Slip: The ratio between the synchronous speed and the operating speed of an induction motor, often expressed
as a percent.
Stator: The stationary part of an AC motor housing the steel laminations and the windings.
Temperature Rise: The difference between the temperature of the windings of an operating motor and the ambient temperature.
Torque: The turning force applied to a shaft, usually expressed as pound-feet (English) or Newton-meters (metric).
Voltage: The standard unit of electromotive force which produces a flow of current in a conductor. The unit of
electromotive force is the volt.
Watt: A measurement of power in an electrical circuit which is equal to one joule of energy being expended in
one second.
712
888-397-5353 USA
kele.com
WHEN YOU NEED IT RIGHT, RIGHT NOW, CALL KELE.