Project Contractor Rep Firm Engineering SAS-RV - STANDARD AUTOMATION SOFT-STARTER 3Ø, 200 ~ 600V, 1/2-75HP Special Instructions: FEATURES AND OPTIONS • Soft start • UL Type 3R Enclosed (4 and 4X available) Full-Load Rated Contactor Bypass Adjustable Current Limit, Initial Voltage, Start/Stop Time SCR Over-Temperature detection Shorted SCR detection Across-the-line Start for Emergency Situations Door mounted Hand/Off/Auto (HOA) keypad • Combination versions include disconnect • Automation compatible Comprehensive inputs/outputs for building automation systems Reduces installation costs Increased energy savings • Electronic motor protection Molded case circuit breaker provides branch and short circuit protection High interrupting ratings for maximum electrical system compatibility No fuses required Lockable handle for safety Optional Features • Surge Supressors Class 10 electronic overload Stall/Locked rotor Phase unbalance Cycle fault Optional factory installed surge supressors (208-240V, or 480-600V) • Universal power supply Automatically detects voltage (200 to 600VAC) Converts to 24V for control power • Control inputs/outputs eliminate interposing relays One N.O dry input for auto run and one wet input for auto run Status relay output SAS-RV Submittal Date Project Contractor Rep Firm Engineering SIZING INFORMATION TABLE UL/NEMA Type 3R/4/4X Outdoor Enclosure Combination Standard Automation Soft Starter - 3-Phase, 200~575VAC Includes Molded Case Circuit Breaker Disconnect UL Three Phase HP SAS-RV Part Number SCIC KAIC @ Contactor NEMA Size Contactor Type Disconnect Part-Number 208V 230V 460V 575V 200/230V 460V 600V SAS[ ]-RV-9/J-G15 2 2 5 5 100 65 14 00 MRC-9B UTE100ENU FTU 15A SAS[ ]-RV-18/J-G20 3 3 7.5 10 100 65 14 0 MRC-18B TD125HU FTU 125 20A SAS[ ]-RV-22/J-G30 5 5 10 15 100 65 14 0+ MRC-22B UTE100ENU FTU 30A SAS[ ]-RV-32/J-G40 5 7.5 15 20 100 65 14 1 MRC-32A UTE100ENU FTU 40A SAS[ ]-RV-40/J-G50 7.5 10 20 25 100 65 14w SAS[ ]-RV-40/J-G60 10 10 25 30 100 65 14 1+ MRC-40A SAS[ ]-RV-50/J-G80 - 15 30 40 100 65 14 2 MRC-50LA TD125HU FTU 125 80A MRC-65LA UTE100ENU FTU 100A UTE100ENU FTU 50A TD125HU FTU 125 60A SAS[ ]-RV-65/J-G100 15 20 40 50 100 65 14 2+ SAS[ ]-RV-85/J-G125 20 25 50 60 100 65 14 3 MRC-85LA TD125HU FTU 125 125A SAS[ ]-RV-100/J-G150 25 30 60 75 100 65 18 3+ MRC-100LA TS250HU FTU 250 150A Standard Automation Soft Starter - 3-Phase, 200~575VAC UL/NEMA Type 3R/4/4X Outdoor Enclosure Standard SCIC KAIC @ UL Three Phase HP SAS-RV Part Number High Fault* SCIC KAIC @ Contactor NEMA SIze Contactor Type 208V 230V 460V 575V 460V 600V SAS[ ]-RV-9/J 2 2 5 7.5 5 100 65 14 00 MRC-9B SAS[ ]-RV-18/J 5 5 10 15 5 100 65 14 0 MRC-18B SAS[ ]-RV-32/J 7.5 10 20 25 5 100 65 14 1 MRC-32A SAS[ ]-RV-40/J 10 10 30 30 5 100 65 14 1+ MRC-40A SAS[ ]-RV-50/J 15 15 30 40 5 100 65 14 2 MRC-50LA SAS[ ]-RV-100/J 25 30 60 75 10 100 65 18 3+ MRC-65LA 200/230V/460V 200/230V *A molded case circuit breaker must be used in order to obtain the high fault SCIC KAIC ratings SAS-RV Options Options Description SAS-SRG240 208-240V surge supressor SAS-SRG480 480-600V surge supressor SAS-RV Submittal Date Project Contractor Rep Firm Engineering SPECIFICATION TABLE SAS-RV Specification Starter Type SAS-RV - Standard Automation Starter - Reduced Voltage (Soft Starter) 200-600VAC, 3-Phase, 50/60Hz input, Reduced voltage starter NEMA Type 3R Enclosedt User Interface Hand-Off-Auto Door mounted Hand-Off-Auto keypad (water-tight-membrane) Programming Internal dials Mode Indication Integrated LEDs, Hand-Off-Auto-Run-Fault indication Standard Control Operations Voltage Atuo-Run Accepts 12-130VAC/DC. Applying voltage will send a run command to the starter when in Auto mode. Inputs Dry Contact Auto-Run Normally Open dry contact. When closed, the starter will be commanded to run when in Auto mode. Normally Open relay contact. Status Relay Status Relay will close when the motor draws a user defined percentage of the FLA setting. Contact Ratings: 0.3A @ 125VAC, 1A @ 24VAC Output Starts 6/hour, 20 seconds max start time @ 400% FLA, 30 seconds max start time @ 300@ FLA Overload Type Electronic, I2t trip curve Operational Power Fail Modes Restart in last mode (Hand/Off/Auto) with no delay (default) Fault Reset Adjustable: Manual or Automatic Environmental Ambient Operating Temp -5° to 140° F (-20° to 60° C) Ambient Storage Temp -5° to 185° F (-20° to 85° C) Relative Humidity 5% to 95% non-condensing Motor / Soft Starter Protection Adjustment / Description Overload Current Setting Range Differs per model Default Setting Per FLA Overload Trip Class Class 10, Trip current = 115% of FLA setting Overload Service Factor 1.15 10 1.15 Cycle Fault Always On,, Trips if contactor cycle rate exceeds 20 starts/minute Current Phase Unbalance Always On, Trips @ 50% current phase unbalance Locked Rotor / Stall Always On,, Trips within 0.5 seconds Shorted SCR Always On, Trips upon detection of a shorted SCR or no motor Open SCR Always On, Trips if no current is detected during startup or bypass SCR Over-Temperature Always On, Trips if any SCR reaches 125oC Across-The-Line Start On/Off, Allows the user to start the motor across-the-line SAS-RV Submittal On 50% On On On On Off Date Project Contractor Rep Firm Engineering SUBMITTED EQUIPMENT SCHEDULE QTY Tag Part # HP Voltage Phase Enclosure Part Number Anatomy SAS3R-RV-32/J-G17 Contactor Size (9, 18, 32, etc.) Disconnect Amperes Rating Enclosure Rating (Type 1 or 3R) SAS Submittal Starter Type Nema Size Date Project Contractor Rep Firm Engineering COMPONENT SPECIFICATIONS The following section details the various components’ sizing and ratings. To locate your component part numbers for the EMS refence the sizing information table above. MANUAL MOTOR STARTERS MOLDED CASE CIRCUIT BREAKERS MOLDED CASE CIRCUIT BREAKER SPECIFICATIONS UTE Series Frame size Rated current ln Number of poles Rated operational voltage, Ue AC Breaking Type AC 50/60Hz A V kA 120/240V 240V 480V 600V Reference standard Available breaker types UTE100 UTE150 UTE100 15–100 3 480 UTE150 40–150 2, 3 600 ET 50 50 25 - Mechanical life Electrical life @600V AC Weight 3-pole lbs (kg) Basic dimension, WxHxD Operations Operations NT 65 65 35 - UL489 Fixed thermal, fixed magnetic, FTU UL489 Fixed thermal, fixed magnetic, FTU Adjustable-thermal, fixed-magnetic, FMU Adjustable-thermal, fixed-magnetic, FMU - Accessories ET 50 50 25 - NT 65 65 35 - Adjustable-thermal, Adjustablemagnetic (3 pole), ATU AX - Auxiliary switch AL - Alarm switch SHT - Shunt trip UVT - Undervoltage trip EHU - Extended rotary handle FH - Flange handle AX - Auxiliary switch AL - Alarm switch SHT - Shunt trip UVT - Undervoltage trip EHU - Extended rotary handle FH - Flange handle PL, PHL - Locking devices (removable, fixed) PL, PHL - Locking devices (removable, fixed) MIT - Mechanical interlock device MIT - Mechanical interlock device 5,000 5,000 1,000 1,000 12.57lbs (5.7kg) 4.19lbs (1.9kg) 2.01 x 5.12 x 3.44in (51 x 130 x 87.5mm) 8.5 x 16.26 x 6in (216x413x152.5mm) SAS-RV Submittal (Reference Only) STOP TIME seconds 10 5 15 20 25 0.2 30 seconds Contractor Dry Project WIRING DIAGRAMS H1 3 4 INITIAL VOLTAGE SAS-RV CONTROL WIRING 5 55 10 CURRENT LIMIT 7 1 8 FLA (A) START TIME 9 Overload Setting (Reference Only) 70 % A2 24V M Output to contactor coil SAS-RV POWER WIRING GATE DRIVE PCB 25 C- A1 H4 40 6 12-250VAC/DC Input Status C+ Contactor Coil PCB Power V1 Normally Open Input O2 O1 Relay Output Keypad 2 V2 Voltage Auto Run Input Engineering Rep Firm Date D2 D1 Auto Run Input CAT-5 CAT-5 L1 L2 L3 250 175 325 100 10 20 25 5 2 MCCB (Optional) S1 Temp Sensor S2 400 % 15 T1 T2 T3 L1 L2 L3 43 31 T1 T2 T3 44 32 T1 T2 T3 30 STOP TIME seconds 10 5 15 20 25 0.2 30 seconds Dry Input D2 D1 Auto Run Voltage Auto Run V2 Input V1 Contactor Coil PCB Power H1 Status C+ L3 L2 L1 SOFT STARTER 24V M Output to A2 contactor coil A1 C- H4 H1 12-250VAC/DC Input O2 O1 Relay Output Keypad OL Normally Open Input T3 T2 M T1 H4 M SAS-RV POWER WIRING L1 L2 3PH L3 MCCB (Optional) STARTER ENCLOSURE DIMENSIONS T1 T2 T3 NOTE: DASHED LINES INDICATE FIELD WIRING UL Type 3R/4/4X Dimensions W OL Starter Size H1 NEMA Size 00–2, Combo NEMA Size 00–1, Combo L3 L2 NEMA Size 2+–3+, Combo L1 SOFT STARTER *All dimensions are in inches T3 T2 H W D 22 15 10 H4 T1 32 L1 L2 L3 43 31 T1 T2 T3 44 32 M 15 10 H T1 T2 T3 M 3PH NOTE: DASHED LINES INDICATE FIELD WIRING D SAS-RV Submittal