Electronic power supplies for short arc xenon lamps EX EX SERIES EX Series Electronic power supplies for short arc xenon lamps A complete range of high quality electronic power supplies expressly designed to ensure correct operation and long life to short arc xenon lamps from 150 to 10000W. They meet all the requirements of lamp manufacturers and have been designed in compliance with the main International Standards. The single-phase and three-phase electronic power supplies offer a wide variety of solutions. Both versions are fitted with galvanic insulation, soft inrush current, a very low ripple value, a stable output current and high efficiency. Remote control can be carried out either through analogical dry contacts, or by means of the digital interface RS 232. The control of the most important lamp parameters, and in particular the electronic overpower control, guarantees a correct lamp operation in all aging conditions and allows long life. Their compact design, light weight and advanced technology make the units suitable for a wide variety of applications. 3 DSP s 6 7 MCU s 1 2 4 IN 5 OUT LAMP IGNITER 1. INPUT EMI FILTER 2. POWER FACTOR CORRECTOR (only on sinlge phase models) 3. CONVERSION BLOCK WITH GALVANIC ISOLATION 5. OUTPUT EMI FILTER 4. RECTIFIER CIRCUIT 7. SYNOPTIC PANEL 6. UP CONTROL BOARD (only on GM3 models) H H B B A Figure 1. A Figure 2. H A B H B A Figure 3. Figure 4. EX Series Xenon lamp power range [W] Electronic power supplies for short arc xenon lamps 150-500 250-500 1000-3000 MODEL EX-30G/1 EX-30G/1 EX-100D/1 Item number model on demand 00830300 00811005 INPUT DATA Mains connection [V] [V] [Hz] [Hz] [A] [W] AC nominal voltage Input voltage range Frequency Frequency range Max. input current Max. power Protection device 1Ph+N+PE (2Ph+PE) 230 90-265 50/60 47-63 10 625 fuse 1Ph+N+PE (2Ph+PE) 230 185-265 50/60 47-63 22 3400 fuse 100 11-22.5 130 15-34 40-110 <1.5 0.83 A/V/W/T/HM mains line - overtemperature operation mode (manual/program) Keyboard/ext. switch/serial line Keyboard/0-10V signal/serial line RS-232 serial line (IREM protocol) lamp ON - alarm ON electronic programmable power limiting DSPs OUTPUT DATA No-load voltage at min. input voltage1 DC output voltage range DC output current range Peak to peak current ripple [V] [V] [A] [%] 6-30 <1.5 0.8 A [LED BAR] mains line - overtemperature Efficiency Output instruments2 Output signal [LCD] [LED] switch potentiometer ON/OFF lamp ON - ignition ready electronic analog ON/OFF control Lamp current adjustment Remote control Output signal [dry contacts] Output overload protection Control system CE Conformity Degree of protection Isolation class Storage temperature Operating temperature [°C] [°C] Cooling Dimensions AxBxH [mm] Figure Weight [kg] Mounting position Suggested igniter 12-30 AS-1530 CE IP20 CL1 -20 to +60 0 to +40 forced 265 x 335 x 135 1 7.7 horizontal / vertical AS-3040 AS-3040 1) 4s after switching on. 2) A = ammeter / V = voltmeter / W = power / T = internal temperature meter / HM = hour meter (partial and total) 3) UL compliance 4) UL certified IREM holds the right to modify the present datasheet without any prior notice CE/UL3 IP20 CL1 -20 to +60 -5 to +45 forced 132,5 x 435,5 x 440 3/4 19,5 horizontal / vertical / rack ASN-700A AS-16040A AS-16035A EX Series Xenon lamp power range [W] Electronic power supplies for short arc xenon lamps 1000-3000 MODEL EX-100GM/3-E EX-100GM/3-E Item number 00831031 00831036 INPUT DATA 3Ph+PE Mains connection [V] [V] [Hz] [Hz] [A] [W] AC nominal voltage Input voltage range Frequency Frequency range Max. input current Max. power 400 360-460 208 187-230 50/60 47-63 11 15 3400 fuse Protection device OUTPUT DATA No-load voltage at min. input voltage1 DC output voltage range DC output current range Peak to peak current ripple [V] [V] [A] [%] 120 17-34 30-110 <1.5 0.87 A/V/W/T/HM mains line - overtemperature operation mode (manual/program) Keyboard / ext. switch / serial line Keyboard / 0-10V signal / serial line RS-232 serial line (IREM protocol) lamp ON - alarm ON electronic programmable power limiting MCUs Efficiency Output instruments2 Output signal [LCD] [LED] ON/OFF control Lamp current adjustment Remote control Output signal [dry contacts] Output overload protection Control system Degree of protection Isolation class Storage temperature Operating temperature [°C] [°C] Cooling Dimensions AxBxH [mm] Figure Weight CE/UL3 CE Conformity [kg] Mounting position Suggested igniter IP20 CL1 -20 to +60 0 to +40 forced 225 x 465 x 350 2 19 horizontal / vertical ASN-700A AS-16035A AS-16040A 1) 4s after switching on. 2) A = ammeter / V = voltmeter / W = power / T = internal temperature meter / HM = hour meter (partial and total) 3) UL compliance 4) UL certified IREM holds the right to modify the present datasheet without any prior notice EX Series Xenon lamp power range [W] Electronic power supplies for short arc xenon lamps 2000-7000 3600-10000 MODEL EX-170GM/3-E EX-170GM/3-US EX-200GM/3-E EX-200GM/3-US Item number 00831731 00831736 00832031 00832036 INPUT DATA 3Ph+PE Mains connection [V] [V] [Hz] [Hz] [A] [W] AC nominal voltage Input voltage range Frequency Frequency range Max. input current Max. power 400 360-460 3Ph+PE 208 187-230 400 360-460 50/60 47-63 18 50/60 47-63 23 7300 fuse Protection device 208 187-230 23 36 10800 fuse circuit breaker OUTPUT DATA No-load voltage at min. input voltage1 DC output voltage range DC output current range Peak to peak current ripple [V] [V] [A] [%] Efficiency Output instruments2 Output signal [LCD] [LED] ON/OFF control Lamp current adjustment Remote control Output signal [dry contacts] Output overload protection Control system CE Conformity Degree of protection Isolation class Storage temperature Operating temperature [°C] [°C] Cooling Dimensions AxBxH [mm] Figure Weight Mounting position Suggested igniter 140 24-46 60-170 <1 0.9 A/V/W/T/HM mains line - overtemperature operation mode (manual/program) Keyboard / ext. switch / serial line Keyboard / 0-10V signal / serial line RS-232 serial line (IREM protocol) lamp ON - alarm ON electronic programmable power limiting MCUs [kg] CE/UL4 IP20 CL1 -20 to +60 0 to +40 forced 255 x 510 x 420 2 30 horizontal / vertical ASN-700A AS-16035A AS-16040A 1) 4s after switching on. 2) A = ammeter / V = voltmeter / W = power / T = internal temperature meter / HM = hour meter (partial and total) 3) UL compliance 4) UL certified IREM holds the right to modify the present datasheet without any prior notice 145 30-58 80-210 <1 0.9 A/V/W/T/HM mains line - overtemperature operation mode (manual/program) Keyboard / ext. switch / serial line Keyboard / 0-10V signal / serial line RS-232 serial line (IREM protocol) lamp ON - alarm ON electronic programmable power limiting MCUs CE/UL4 CE IP20 CL1 -20 to +60 0 to +40 forced 255 x 510 x 420 2 33 horizontal / vertical ASN-1000A IREM SpA - Via Abegg 75 10050 Borgone - Torino - ITALY Tel. ++39 011 9648211 - Fax ++39 011 9648222 e-mail: irem@irem.it - www.irem.it N3-50E N3-80E N3-100E N3-150E N3-180E N3-50 N3-80 N3-100 N3-150 N3-180 N3-200 N3-400 N3-E N3 99533945.05 AS 180W 250W 500W 700W 900W 1000W 1600W 2000W 2500W 3000W 3600W 4000W 4500W 5000W 6500W 7000W 8000W 10000W 12000W 15000W INDICATIVE DATA. LAMP CHARACTERISTICS MAY CHANGE DEPENDING ON MANUFACTURER. IT IS ADVISABLE TO CHECK IF LAMP CHARACTERISTICS MATCH THE BALLAST AND IGNITER. 150W www.think-adv.com AS-1530 AS-3040 AS-8030 ASN-700 AS-16035 AS-16040 ASD-16040 ASN-1000 ASD-20050A AS-40045 EX-30G/1 EX-100GM/3 EX EX-170GM/3 EX-200GM/3 EX-100D/1 IGNITERS P-X50N PX RECTIFIERS SERIES MODELS XENON LAMP POWER IREM CROSS REFERENCES FOR XENON LAMPS RECTIFIERS AND IGNITERS