OPR - Exhibit B 09/2014 SECTION 282300 - VIDEO SURVEILLANCE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. 1.2 Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. SUMMARY A. 1.3 Section includes a video surveillance system consisting of cameras, network video recorder, data transmission wiring, and a client workstation station with its associated equipment. DEFINITIONS A. AGC: Automatic gain control. B. BNC: Bayonet Neill-Concelman - type of connector. C. B/W: Black and white. D. CCD: Charge-coupled device. E. FTP: File transfer protocol. F. IP: Internet protocol. G. IP Encoder: IP Encoders convert analog video to IP video streams. H. LAN: Local area network. I. MTS: Mercy Technology Services. J. MP: Megapixel. K. MPEG: Moving picture experts group. L. NTSC: National Television System Committee. M. PC: Personal computer. N. PoE: Power over Ethernet. O. PTZ: Pan-tilt-zoom. P. RAID: Redundant array of independent disks. VIDEO SURVEILLANCE – Typical Clinic 282300 - 1 OPR - Exhibit B Q. TCP: Transmission control protocol - connects hosts on the Internet. R. TB: Terabyte. S. UPS: Uninterruptible power supply. T. WAN: Wide area network. 1.4 09/2014 ACTION SUBMITTALS A. Product Data: For each type of product indicated. Include dimensions and data on features, performance, electrical characteristics, ratings, and finishes. B. Shop Drawings: For video surveillance. attachments to other work. 1. 2. 3. C. 1.5 Include plans, elevations, sections, details, and Detail equipment assemblies and indicate dimensions, weights, loads, required clearances, method of field assembly, components, and location and size of each field connection. Functional Block Diagram: Show single-line interconnections between components for signal transmission and control. Show cable types and sizes. Wiring Diagrams: For power, signal, data, and control wiring. Equipment List: Include every piece of equipment by model number, manufacturer, serial number, location, and date of original installation. Add pretesting record of each piece of equipment, listing name of person testing, date of test, set points of adjustments, name and description of the view of preset positions, description of alarms, and description of unit output responses to an alarm. CLOSEOUT SUBMITTALS A. 1.6 Operation and Maintenance Data: For cameras, operation, and maintenance manuals. QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. B. Comply with NECA 1. C. Comply with NFPA 70. 1.7 PROJECT CONDITIONS A. Environmental Conditions: Capable of withstanding the following environmental conditions without mechanical or electrical damage or degradation of operating capability: VIDEO SURVEILLANCE – Typical Clinic 282300 - 2 OPR - Exhibit B 1. 2. 3. 4. 5. 6. 7. 1.8 09/2014 Control Station: Rated for continuous operation in ambient temperatures of 60 to 85 deg F (16 to 29 deg C) and a relative humidity of 20 to 80 percent, noncondensing. Interior, Controlled Environment: System components installed in temperature-controlled interior environments shall be rated for continuous operation in ambient temperatures of 36 to 122 deg F (2 to 50 deg C) dry bulb and 20 to 90 percent relative humidity, noncondensing. Use NEMA 250, Type 1 enclosures. Interior, Uncontrolled Environment: System components installed in non temperaturecontrolled interior environments shall be rated for continuous operation in ambient temperatures of 0 to 122 deg F (minus 18 to plus 50 deg C) dry bulb and 20 to 90 percent relative humidity, noncondensing. Use NEMA 250 enclosures. Exterior Environment: System components installed in locations exposed to weather shall be rated for continuous operation in ambient temperatures of minus 30 to plus 122 deg F (minus 34 to plus 50 deg C) dry bulb and 20 to 90 percent relative humidity, condensing. Rate for continuous operation when exposed to rain as specified in NEMA 250, winds up to 85 mph (137 km/h) and snow cover up to 24 inches (610 mm) thick. Use NEMA 250enclosures. Hazardous Environment: System components located in areas where fire or explosion hazards may exist because of flammable gases or vapors, flammable liquids, combustible dust, or ignitable fibers shall be rated, listed, and installed according to NFPA 70. Corrosive Environment: System components subject to corrosive fumes, vapors, and wind-driven salt spray in coastal zones. Use NEMA 250 enclosures. Security Environment: Camera housing for use in high-risk areas where surveillance equipment may be subject to physical violence. WARRANTY A. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of cameras, equipment related to camera operation, and control-station equipment that fail in materials or workmanship within specified warranty period. 1. Warranty Period: One year from date of Substantial Completion. PART 2 - PRODUCTS 2.1 SYSTEM REQUIREMENTS A. Software and Licensing: 1. Genetec Security Center (GSC) Base Package – Latest version of Genetec Security Center supported by MTS which includes: Directory, 5 Security Desk client connections, Plan Manager Basic for 3 maps and 30 entities, Alarm Management, Advanced Reporting, System Partitioning, Zone Monitoring, Email Support, Macros Support (actual macros sold separately), all supported languages. Must purchase a Synergis, Omnicast, or AutoVu base package to enable video, or LPR content respectively. GSC-Base-5.2 2.GSC Omnicast Enterprise Package which includes: Archiving support, Media Router, Audio, Camera Sequences, Time Zone, Edge recording and trickling, 1Keyboard connection, Max. 300 cameras per Archiver / 100 cameras on the Directory machine. GSC-Om-E VIDEO SURVEILLANCE – Typical Clinic 282300 - 3 OPR - Exhibit B 09/2014 3.Optional-Security Center Mobile app connection (mobile app or web client). GSC-1MobileU 4. Optional-Remote Security Desk. Only available with Professional or Enterprise packages (Synergis and/or Omnicast). GSC-RSD 5. Security Center Active Directory Integration (users only). Enables Windows user accounts to be linked to Security Center user accounts. Only available with Professional or Enterprise packages (Synergis and/or Omnicast) or AutoVu Standard package. Includes 1 connection to an Active Directory server. GSC-1AD-US 6. Federated Security Center 4.0 (or higher) Directory connection. Must purchase Omnicast or Synergis Enterprise Package. GSC-1SCFED 7. Enterprise Camera Connection GSC-Om-E-3C 8. SMA for 3 Omnicast Enterprise Camera - 1 year SMA-CAM-E-1Y 2.2 IP CAMERAS A. Basis-of-Design Product: Subject to owner preference, provide Axis Communications, Bosch, Sony or Panasonic manufacturer model IP cameras. Video coverage and/or environment may require the use of additional camera types (e.g., PTZ, Fixed, Fixed Dome, Covert, etc.) and will vary depending on the project. Audio enabled IP cameras are to be provided at the owner’s request. B. Example of Exterior Camera: Axis P3364-VE Designed for high-abuse locations, with a weather tight enclosure, mounting brackets, impact-resistance polycarbonate dome, and heavygage aluminum body. 1. Suitable for exterior environment, rated for continuous operation in ambient temperatures of -40 °C to 55 °C (-40 °F to 131 °F) Humidity 10 - 100% RH (condensing) 2. Resolution: 1280x960 (approx. 1.3 MP) to 320x240 3. Video Compression: H.264 Baseline and Main Profile (MPEG-4 Part 10/AVC) Motion JPEGWhite Balance: Auto-tracing white balance. C. Example of Interior Camera: Axis P3354 designed for indoor application with low environmental impact and abuse. Includes polycarbonate transparent cover, aluminum inner camera module with encapsulated electronics, and tamper-resistant polycarbonate casing. 1. Suitable for interior environment rated for continuous operation in ambient temperatures of 0 °C to 50 °C (32 °F to 122 °F) Humidity 10 - 85% RH (non-condensing) 2. Resolution: 1280x960 (approx. 1.3 MP) to 320x240 3. Video Compression: H.264 Baseline and Main Profile (MPEG-4 Part 10/AVC) Motion JPEGWhite Balance: Auto-tracing white balance. D. Resolution Requirements- Subject to application requirements and owner preference 1. Max Resolution range 1280x960 (approx 1 MP) - 2592x1944 (5 MP) 2. Minimum Resolution 160x90 – 320x180 VIDEO SURVEILLANCE – Typical Clinic 282300 - 4 OPR - Exhibit B 2.3 09/2014 CAMERA-SUPPORTING EQUIPMENT A. Basis-of-Design Product: Subject to compliance with requirements and camera manufacturer models.Example: Axis wall bracket model 5017-611 and Axis 5502-321. Camera type, mounting surface, and environment will require the use of additional Axis Communications wall brackets and will vary depending on project. Mount to ceiling tile when possible. B. Minimum Load Rating: Rated for load in excess of the total weight supported times a minimum safety factor of two. C. Minimum-Maximum Install Height: All pole mounted IP devices shall be mounted no less than 12 feet and no more than 16 feet from the ground 2.4 NETWORK VIDEO RECORDERS A. Basis-of-Design Product: Subject to compliance with project requirements and owner preference. 1. Video Archive Servers- Provide Genetec SVPROv2 preloaded with Genetec software or Dell PowerEdge R720 server directory/archiver Dual Intel® Xeon® E5-2690 2.90GHz, 20M Cache, 8.0GT/s QPI, Turbo, 8C, 135W, Max Mem 1600MHz 16GB UDIMM, 1333 MT/s, Low Volt, Dual Rank, x8 Data Width Windows Server® 2012,Standard Ed,Factory Install,No MED,2 Socket,2 VMs Windows Server® 2012, Standard Edition, RAID Configuration: RAID 5 for H710P/H710/H310 (3-16 HDDs)RAID Controller: PERC H710P Integrated RAID Controller, 1GB NV Cache (8) 4TB 7.2K RPM NearLine SAS 6Gbps 3.5in Hot-plug Hard Drive 4TBSAHP Dual, Hot-plug, Redundant Power Supply (1+1), 750W. 2. Video Management Client PCs- To be provided by Mercy Technology Services PART 3 - EXECUTION 3.1 EXAMINATION A. Examine pathway elements intended for cables. Check raceways and other elements for compliance with space allocations, installation tolerance, hazards to camera installation, and other conditions affecting installation. B. Examine roughing-in for LAN, WAN, and IP network before device installation. C. Proceed with installation only after unsatisfactory conditions have been corrected. 3.2 WIRING A. Comply with requirements in Section 260533 "Raceways and Boxes for Electrical Systems." B. Wiring Method: Install cables in raceways unless otherwise indicated. VIDEO SURVEILLANCE – Typical Clinic 282300 - 5 OPR - Exhibit B 1. 2. 3. 09/2014 Except raceways are not required in accessible indoor ceiling spaces and attics. Except raceways are not required in hollow gypsum board partitions. Conceal raceways and wiring except in unfinished spaces. C. Wiring within Enclosures: Bundle, lace, and train conductors to terminal points with no excess and without exceeding manufacturer's limitations on bending radii. Provide and use lacing bars and distribution spools. D. Splices, Taps, and Terminations: For power and control wiring, use numbered terminal strips in junction, pull, and outlet boxes; terminal cabinets; and equipment enclosures. Tighten electrical connectors and terminals according to manufacturer's published torque-tightening values. If manufacturer's torque values are not indicated, use those specified in UL 486A-486B. E. For LAN connection and fiber-optic and copper communication wiring, comply with Section 271300 "Communications Backbone Cabling" and Section 271500 "Communications Horizontal Cabling." F. Grounding: Provide independent-signal circuit grounding recommended in writing by manufacturer. G. Any exterior IP device requiring a network cable that is more than the maximum allowed 300 feet will require a fiber-optic cable and PoE media converter. H. Surge protection is required for all exterior mounted IP devices. APC PRM24 24-Position Surge Suppressor Chassis preferred. 3.3 VIDEO SURVEILLANCE SYSTEM INSTALLATION A. Install cameras level and plumb. B. Install cameras with 84-inch- (2134-mm-) minimum clear space below cameras and their mountings. Change type of mounting to achieve required clearance. C. Identify system components, wiring, cabling, and terminals according to Section 260553 "Identification for Electrical Systems." D. Coordinate with Mercy Technology Services (MTS) for active, PoE enabled (when required), data connections, IP configurations, and IP Addresses. E. Manufacturer's Field Service: Engage a factory-authorized service representative to inspect, test, adjust components, assemblies, and equipment installations, including connections and ensure firmware installed on IP video devices is the latest version supported by Genetec Security Center. F. Perform tests and inspections. 1. G. Manufacturer's Field Service: Engage a factory-authorized service representative to inspect components, assemblies, and equipment installations, including connections, and to assist in testing. Tests and Inspections: VIDEO SURVEILLANCE – Typical Clinic 282300 - 6 OPR - Exhibit B 1. 2. Inspection: Verify that units and controls are properly installed, connected, and labeled, and that interconnecting wires and terminals are identified. Pretesting: Align and adjust system and pretest components, wiring, and functions to verify that they comply with specified requirements. Conduct tests at varying lighting levels, including day and night scenes as applicable. Prepare video-surveillance equipment for acceptance and operational testing as follows: a. b. c. d. e. f. g. h. 3. 4. 09/2014 Prepare equipment list described in "Informational Submittals" Article. Verify operation of auto-iris lenses. Set back-focus of fixed focal length lenses. At focus set to infinity, simulate nighttime lighting conditions by using a dark glass filter of a density that produces a clear image. Adjust until image is in focus with and without the filter. Set back-focus of zoom lenses. At focus set to infinity, simulate nighttime lighting conditions by using a dark glass filter of a density that produces a clear image. Additionally, set zoom to full wide angle and aim camera at an object 50 to 75 feet (17 to 23 m) away. Adjust until image is in focus from full wide angle to full telephoto, with the filter in place. Set and name all preset positions; consult local Owner's personnel. Set sensitivity of motion detection. Connect and verify responses to alarms. Verify operation of control-station equipment. Test Schedule: Schedule tests after pretesting has been successfully completed and system has been in normal functional operation for at least 14 days. Provide a minimum of 10 days' notice of test schedule. Operational Tests: Perform operational system tests to verify that system complies with Specifications. Include all modes of system operation. Test equipment for proper operation in all functional modes. H. Video surveillance system will be considered defective if it does not pass tests and inspections. I. Prepare test and inspection reports. 3.4 ADJUSTING A. Occupancy Adjustments: When requested within 12 months of date of Substantial Completion, provide on-site assistance in adjusting system to suit actual occupied conditions. Provide up to [one] 1 visits to Project during other-than-normal occupancy hours for this purpose. Tasks shall include, but are not limited to, the following: 1. 2. 3. 4. 5. 6. Check cable connections. Check proper operation of cameras and lenses. Verify operation of auto-iris lenses and adjust back-focus as needed. Adjust all preset positions; consult local Owner's personnel. Recommend changes to cameras, lenses, and associated equipment to improve Owner's use of video surveillance system. Provide a written report of adjustments and recommendations. Move camera to a location located within service loop distance if the original camera view is obstructed or otherwise compromised by unforeseen changes in the surrounding environment. VIDEO SURVEILLANCE – Typical Clinic 282300 - 7 OPR - Exhibit B 3.5 09/2014 CLEANING A. Clean installed items using methods and materials recommended in writing by manufacturer. B. Clean video-surveillance-system components, including camera-housing windows, lenses, and monitor screens upon occupancy post-construction. 3.6 DEMONSTRATION A. Engage a factory-authorized service representative to train end users based on owner's designated personnel to adjust, operate, and maintain video-surveillance equipment and provide end-user training on the Genetec video management system. END OF SECTION 282300 - ww VIDEO SURVEILLANCE – Typical Clinic 282300 - 8