MODEL VM-5Y4 RELAY MODULE UNIT (CONNECTOR TYPE) VM-5 SERIES MONITOR SPECIFICATIONS Model Code / Additional Spec. Code( VM-5Y4 Arc suppressor 0 1 Provided Not provided Input 1 2 CA Series,CV-86 *1 CV-85,CV-87 *2 VK,RD,FK,MS VC,VM-11P,VM-21P Note) *1 *2 - Contact method (DANGER) 1 NO 2 NC No entry if additional spec. code is not specified. Contact method Tropical Husing fix screw size CE marking (OK) spec. 1 NO 0 #4-40UNC 2 NC 1 M2.6×0.45 2-wire transducer requiring a constant current power supply (4mA, 24VDC). 3-wire transducer requiring a -24VDC power supply, or any other transducer that does not cause power to be supplied from the monitor to the transducer. Standard Specifications I/O CONNECTOR TERMINAL BLOCK /TRP/CEM Contact method (ALERT) 1 NO 2 NC ) D-Sub 9P connector 1pc.(CN1) CN1 : Recorder output 2CH Alarm output L : -1 to +1V H : +4V to +6V OK, ALERT, DANGER (each 2 points) Housing fix screw : #4-40UNC or M2.6×0.45 Specified when ordering. Unless specified otherwise, preset to #4-40UNC. Recommended connector(Socket side) Connector Housing XM2D-0901 XM2S-0913(#4-40UNC) XM2S-0911(M2.6×0.45 ) [OMRON] GM(E)-9F GM-9LD55GU(#4-40UNC) GM-9LD55G(M2.6×0.45 ) [HONDA] Terminal block 16P Input transducer : 2CH Contact output : OK 1 point (OR state of CH1 and CH2) ALERT, DANGER (each 2 points) Standard Specifications RELAY POINTS POWER OUTPUT FOR TRANSDUCER CONTACT RATING (LOAD RESISTANCE) CONTACT LIFE PROTECTIVE CONSTRUCTION TEMPERATURE RANGE MASS OTHERS 5 points (DANGER1,ALERT1,DANGER2,ALERT2,OK) Model Code No. of input signal “1” : 2 wire constant current power supply 4mA,24VDC Model Code No. of input signal “2” : -24VDC,40mA 250VAC, 5A 30VDC, 5A 100,000 times or more (rated load) Plastic seal Operating temperature : 0 to 65°C (32 to 149°F) Storage temperature : -30 to +85°C (-22 to +185°F) Relative humidity : 20 to 95% (noncondensing) max.0.4kg Note) VM-5Y4 RELAY MODULE UNIT can not correspond to isolation recorder output specification. Alarm contact operation Monitor alarm relay mode Monitor power OFF NO contact NORMALLY DE-ENERGIZED NO contact NORMALLY ENERGIZED NC contact NORMALLY DE-ENERGIZED NC contact NORMALLY ENERGIZED OPEN OPEN CLOSE CLOSE Monitor power ON Normal state Alarm state OPEN CLOSE CLOSE OPEN CLOSE OPEN OPEN CLOSE 39624E2.7 Issued : Feb.1997 Revised : Jun.2008 MODEL VM-5Y5 VM-5 SERIES MONITOR RELAY MODULE UNIT FOR VIBRATION MONITOR (CONNECTOR TYPE) SPECIFICATIONS Model Code / Additional Spec. Code( VM-5Y5Arc suppressor 0 1 Provided Not provided Input 1 2 CA Series,CV-86 *1 CV-85,CV-87 *2 VK,FK VC Note) *1 *2 - Contact method (DANGER) 1 NO 2 NC No entry if additional spec. code is not specified. Contact method Tropical Husing fix screw size CE marking (OK) spec. 1 NO 0 #4-40UNC 2 NC 1 M2.6×0.45 2-wire transducer requiring a constant current power supply(4mA, 24VDC). 3-wire transducer requiring a -24VDC power supply, or any other transducer that does not cause power to be supplied from the monitor to the transducer. Standard Specifications I/O CONNECTOR TERMINAL BLOCK /TRP/CEM Contact method (ALERT) 1 NO 2 NC ) Standard Specifications D-Sub 9P connector 1pc.(CN1) CN1 : Buffer output 1CH Alarm output L : -1 to +1V H : 4V to 6V OK (1 point), ALERT, DANGER (each 2 points) Housing fix screw : #4-40UNC or M2.6×0.45 Specified when ordering. Unless specified otherwise, preset to #4-40UNC. Recommended connector(Socket side) Connector Housing XM2D-0901 XM2S-0913(#4-40UNC) XM2S-0911(M2.6×0.45 ) [OMRON] GM(E)-9F GM-9LD55GU(#4-40UNC) GM-9LD55G(M2.6×0.45 ) [HONDA] Terminal block 16P Input transducer : 1CH Contact output : OK 1 point ALERT, DANGER (each 2 points) Recorder output : 1CH RELAY POINTS POWER OUTPUT FOR TRANSDUCER CONTACT RATING (LOAD RESISTANCE) CONTACT LIFE PROTECTIVE CONSTRUCTION TEMPERATURE RANGE MASS 5 points (DANGER1, ALERT1, DANGER2, ALERT2, OK) Model Code No. of input signal “1” : 2 wire constant current power supply 4mA, 24VDC Model Code No. of input signal “2” : -24VDC, 40mA 250VAC, 5A 30VDC, 5A 100,000 times or more (rated load) Plastic seal Operating temperature : 0 to 65°C (32 to 149°F) Storage temperature : -30 to +85°C (-22 to +185°F) Relative humidity : 20 to 95% (noncondensing) max.0.4kg OTHERS Note) VM-5Y5 RELAY MODULE UNIT can not correspond to isolation recorder output specification. Alarm contact operation Monitor alarm relay mode Monitor power OFF NO contact NORMALLY DE-ENERGIZED NO contact NORMALLY ENERGIZED NC contact NORMALLY DE-ENERGIZED NC contact NORMALLY ENERGIZED OPEN OPEN CLOSE CLOSE Monitor power ON Normal state Alarm state OPEN CLOSE CLOSE OPEN CLOSE OPEN OPEN CLOSE 39625E2.8 Issued : Feb.1997 Revised : Sep.2006 MODEL VM-5Y6 VM-5 SERIES MONITOR RELAY MODULE UNIT FOR MAGNETIC PICKUP (CONNECTOR TYPE) SPECIFICATIONS Model Code / Additional Spec. Code( VM-5Y6Arc suppressor 0 1 Provided Not provided Input 1 ONO SOKKI MP-981 0 Contact method (DANGER) 1 NO 2 NC No entry if additional spec. code is not specified. /TRP/CEM Contact method (ALERT) 1 NO 2 NC Contact method (OK) 1 NO 2 NC Standard Specifications I/O CONNECTOR TERMINAL BLOCK ) Husing fix screw size 0 1 Tropical CE marking. spec. #4-40UNC M2.6×0.45 Standard Specifications D-Sub 9P connector 1pc(CN1) CN1 : Recorder output 2CH Alarm output L : -1 to +1V H : 4V to 6V OK, ALERT, DANGER (each 2 points) Housing fix screw : #4-40UNC or M2.6×0.45 Specified when ordering. Unless specified otherwise, preset to #4-40UNC. Recommended connector(Socket side) Connector Housing XM2D-0901 XM2S-0913(#4-40UNC) XM2S-0911(M2.6×0.45 ) [OMRON] GM(E)-9F GM-9LD55GU(#4-40UNC) GM-9LD55G(M2.6×0.45 ) [HONDA] Terminal block 16P Input transducer: 2CH Contact output : OK 1 point (OR state of CH1and CH2) ALERT, DANGER (each 2 points) RELAY POINTS POWER OUTPUT FOR PICKUP CONTACT RATING (LOAD RESISTANCE) CONTACT LIFE PROTECTIVE CONSTRUCTION TEMPERATURE RANGE MASS OTHERS 5opints (DANGER1, ALERT1, DANGER2, ALERT2, OK) 12VDC, 40mA 250VAC,5A 30VDC,5A 100,000 times or more (rated load) Plastic seal Operating temperature : 0 to 65°C (32 to 149°F) Storage temperature : -30 to +85°C (-22 to +185°F) Relative humidity : 20 to 95% (noncondensing) max.0.4kg Note) VM-5Y6 RELAY MODULE UNIT can not correspond to isolation recorder output specification. Alarm contact operation Monitor alarm relay mode Monitor power OFF NO contact NORMALLY DE-ENERGIZED NO contact NORMALLY ENERGIZED NC contact NORMALLY DE-ENERGIZED NC contact NORMALLY ENERGIZED OPEN OPEN CLOSE CLOSE Monitor power ON Normal state Alarm state OPEN CLOSE CLOSE OPEN CLOSE OPEN OPEN CLOSE 39626E1.5 Issued : Jul.1997 Revised : Sep.2003