Network Transmission Industrial Hardened Power Supply Overview Standard Features GE’s Industrial Hardened Power Supply is now IFS. Engineered for optimal performance in harsh environmental conditions, the IFS 48 VDC (240W) Hardened Power Supply is designed to perform under full-load in industrial environments where dust and condensation can be a problem and when operating temperatures range from -30°C to 70°C. Hardened Design • 48 VDC @ 5 amp (240W) output for industrial PoE switches • IP 67/IP 65 rates industrial closure is rated for environmental protection in harsh dust and high-humidity environments Reliability and safety are enhanced by free-air cooling, eliminating potential mechanical breakdowns and wear from moving parts. Short circuit/overload protection, as well as over voltage and temperature recovery features, protect against damage with an automatic recovery function that does not require user intervention. The unit is equipped with an industry standard IEC connector allowing for the appropriate regional power plug to be used for installation. • Cooled by free air with no fan or moving parts required, increasing reliability • Over voltage and over temperature recovery automatically protects against damage without user intervention The advanced switching power supply technology reduces power consumption, meeting Level IV (4) International Efficiency in compliance with California Energy Commission, Energy Star and the EU Code of Conduct for external power supplies. Supplies can be mixed and matched to a variety of IFS products to meet installation requirements. This power supply is ideal for use with industrial network equipment, such as switches with full PoE power per port, in harsh environments. 48 VDC Hardened 240W Power Supply • Wide operating temperature -30°C to 70°C Reliability and Safety Installation • Universal IEC male power input plug accommodates IEC power cords regardless of country location • Low-voltage flying leads provides easy power interface termination • Wall mount design easily mounts to walls and cabinets Specifications Output DC Voltage 48V Constant Current Region 24~48V Rated Current 5A Rated Power 240W Ripple & Noise (max.) 250mVp-p Voltage ADJ. Range 44.8~51.2V Current ADJ. Range 2.5~5A (Can be adjusted by internal potential meter) Voltage Tolerance ±1.0% Line Regulation ±0.5% Load Regulation ±0.5% Setup, Rise Time 2500ms, 80ms at full load 230VAC/115VAC Hold Up Time (Typ.) 15ms at full load 230VAC/115VAC Input Voltage Range 90~264VAC, 127~373VDC Frequency Range 47~63Hz Power Factor PF>=0.95/230VAC, PF>=0.98/115VAC at full load and rated output voltage, PF>=0.95 at 65 ~ 100% load Efficiency (Typ.) 94% AC Current 4A/115VAC, 2A/230VAC Inrush Current (Typ.) Cold start 75A/230VAC Leakage Current <0.75mA/240VAC Protection Over Current 95~108%, Protection type: Constant current limiting, recovers automatically after fault condition is removed Short Circuit Hiccup mode, recovers automatically after fault condition is removed Over Voltage 53~62V, Protection type: Shut down and latch off o/p voltage, re-power on to recover Over Temperature 95ºC±5ºC (TSW1), Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed Environment Working Temperature -40º ~ to 60ºC @ full load; +70ºC @ 60% load (Refer to derating curve) Working Humidity 20 ~ 95% RH non-condensing Storage Temperature, Humidity -40 ~ +80ºC, 10 ~ 95% RH Temperature Coefficient ±0.03%/ºC (0~50ºC) Vibration 10 ~ 500Hz, 5G 12min./1 cycle, period for 72 min. each along X, Y, Z axes Safety & EMC Safety Standards UL1012, TUV EN61347-1, EN61347-2-13 independent (except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67 approved Withstand Voltage I/P-O/P:3.75KVAC Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC / 70% RH EMI Conduction & Radiation Compliance to EN55015, EN55022 (CISPR22) Class B Harmonic Current Compliance to EN61000-3-2 Class C (>=50% load) ; EN61000-3-3 EMS Immunity Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A I/P-FG:1.88KVAC O/P-FG:0.5KVAC Others MTBF 207.9Khrs min. Dimensions (LxWxH) 9.61 x 2.67 x 1.52 in., 244.2 x 68 x 38.8mm MIL-HDBK-217F (25ºC) Weight 2.8 lbs., 1.3Kg 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 9. Refer to warranty statement. FG FG FGFG PWM & PFC CONTROL PWM PWM &PFC PFC PWM && PFC CONTROL CONTROL CONTROL PFC CONTROL PFC PFC PFC CONTROL CONTROL CONTROL Derating Curve O.V.P. O.V.P. O.V.P. O.V.P. Static Characteristics 230VAC 230VAC 230VAC 230VAC 100VAC 100VAC 100VAC 100VAC 40 40 4040 20 20 2020 -40 -25 -10 0 15 30 50 60 70 (HORIZONTAL) -40 -40-25 -25 -25-10 -10 -10 0 00 1515 153030 30 5050 50 6060 60 7070 70 (HORIZONTAL) (HORIZONTAL) -40 (HORIZONTAL) AMBIENT TEMPERATURE (ºC) AMBIENT AMBIENT TEMPERATURE TEMPERATURE (ºC) (ºC) AMBIENT TEMPERATURE (ºC) Power Factor Characteristic CONSTANT CURRENT MODE CONSTANT CONSTANT CURRENT CURRENT MODE MODE CONSTANT CURRENT MODE 1.02 1.02 1.02 1.02 1 230V 11 10.98 230V 230V 230V 0.98 0.98 0.98 0.96 110V 0.96 0.96 110V 110V 0.960.94 110V 0.94 0.94 0.94 0.92 0.92 0.92 0.92 0.9 0.9 0.90.9 0.88 0.88 0.88 0.88 0.86 0.86 0.86 0.86 0.84 0.84 0.84 0.84 0.82 0.82 0.82 0.82 0.8 0.830% 40% 50% 60% 70% 80% 90% 100% 0.80.8 30%40% 40%50% 50% 60% 60%70% 70%80% 80%90% 90%100% 100% 30% 40% 50% 60% 70% 80% 90% 100% 30% LOAD LOAD LOAD LOAD Efficiency vs. Load (48V Model) EFFICIENCY (%) EFFICIENCY (%) EFFICIENCY (%) EFFICIENCY (%) 96 96 9696 94 94 9494 230V 92 230V 230V 230V 92 9292 90 110V 90 9090 110V 110V 110V 88 88 8888 86 86 8686 84 84 8484 82 82 8282 80 80 8080 78 78 7878 76 76 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 7676 0% 0% 10% 10% 20% 20% 30% 30% 40% 40% 50% 50% 60% 60% 70% 70% 80% 80% 90% 90% 100% 100% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD LOAD LOAD LOAD ADJ2 (BADJ2 Type) ADJ2 (BType) Type) (B(B Type) 100 100 100 100 90 90 9090 80 80 8080 70 70 7070 60 60 6060 50 50 5050 40 40 40 40 fosc: 100KHz fosc: fosc: 100KHz 100KHz fosc: 100KHz LOAD (%) LOAD (%) LOAD (%) LOAD (%) LOAD (%) LOAD (%) LOAD (%) LOAD (%) 100 100 100 100 80 80 8080 60 60 6060 DETECTION CIRCUIT DETECTION DETECTION DETECTION CIRCUIT CIRCUIT CIRCUIT 90 100 125 135 145 155 165 175 180 200 230 264 90 100 100 125 125 135 135 145 145 155 155 165 165 175 175 180 180 200 200 230 230 264 264 9090 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60HZ INPUT INPUT VOLTAGE VOLTAGE (V) (V) 60HZ 60HZ INPUT VOLTAGE (V) 60HZ 38.8 Dimensional Diagram North America T 888-437-3287 F 503-691-7566 E sales@ifs.com 9.61 in. (244.2 mm) 8.66 in. (220.2 mm) 2.67 in. (68 mm) Asia T 852-2907-8108 F 852-2142-5063 Australia and New Zealand T 613-9239-1200 F 613-9239-1299 38.8 Europe T 44-113-238-1668 F 44-113-253-8121 Latin America T 561-998-6100 F 561-994-6572 244.2 interlogix.com ufcfireandsecurity.com Ordering Information GE and the GE monogram are trademarks of the General Electric Company and are under license to UTC Fire & Security, 9 Farm Springs Road, Farmington, CT 06034-4065 9.4 300 20 HLG-240-48 48 Volt D.C. (240W) Single Output, Environmentally Hardened Switching Power Supply 2 2 2 +V(Red) -V(Black) ADJ1(Blue) ADJ2(White) 4.2 4PL 38.8 AC/L(Brown) AC/N(Blue) Company. 300 20 34.2 68 © 2011 Interlogix, A UTC Fire & Security All rights reserved. 9.6 9.4 Specifications subject to change without notice. 220.2 12 102-3400 2011/02 (64771)