Thermal Overcurrent Circuit Breaker 1410-L1/L4 2

advertisement
Thermal Overcurrent Circuit Breaker 1410-L1/L4
Description
Single pole press-to-reset thermal circuit breaker with extremely fast
overload switching performance (R-type TO CBE to EN 60934).
Miniaturised construction minimises PCB real estate required.
PCB mounting or integral mounting. Largely temperature-insensitive.
Typical applications
Motors, transformers, solenoids, PCBs, hand-held machines, appliances,
instrumentation.
Ordering information
1410-L1...
Type No.
1410 single pole circuit breaker
Configuration
L integral mounting or PCB mounting
Mounting
1 footprint 16.3x4.6
4 footprint 17.5x4.6
Number of poles
1 1-pole, thermally protected
Hardware
0 without
Terminal design
L1 solder pins 1.8x0.8 silver-plated (-L1 only)
P3 blade terminals DIN 46244-A4.8-0.5 silver-plated (only -L4)
Characteristic curve
F1 fast acting
Actuator, Type and Colour
S01
reset button, black (1410-L1)
E04
round reset slide, red (1410-L4)
Current ratings
0.63...10 A
1410 -L 1 1 0 - L1 F1 - S01 - 0.8 A
ordering example
*mounting hardware bulk shipped
Preferred types
Preferred types
Standard current ratings (A)
0.63 0.8 1 1.5 2 2.5 3.15 4 5 6.3 8 10
1410-L110-L1F1S01-
x
x
x
x
x
x
x
x
x
x
x
x
Standard current ratings and typical internal resistance values
Current
rating (A)
Internal
resistance (Ω)
Current
rating (A)
Internal
resistance (Ω)
0.63
0.8
1
1.5
1.8
2
2.5
1.8
1.7
1.3
<1
<1
<1
< 0.15
3.15
4
5
6.3
8
10
<
<
<
<
<
<
2015/16
0.12
0.1
0.1
0.1
0.1
0.1
1410-L4...
2
Technical data
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 28 V
(UL: AC 250 V; DC 50 V)
Current rating range 1-2 0.63...10 A
Typical life
AC 240 V: 0.63...2.25 A 500 break operations at 2 x IN, inductive
2.5...10 A
500 break operations at 2 x IN, resistive
DC 50 V: 0.63...2.25 A 500 break operations at 2 x IN, inductive
DC 28 V: 2.5...10 A
500 break operations at 2 x IN, inductive
Ambient temperature
-20...+70 °C (-4...+158 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity Icn 0.63...2 A
12 x IN
(o-o-o)
2.5...8 A 8 x IN, AC max. 50 A
10 A
6 x IN, AC
3.15...10 A 10 x IN, DC
Interrupting capacity
0.63...10 A 2,000 A AC 250 V
(UL 1077)
0.63...10 A 200 A
DC 50 V
Degree of protection operating area IP40
(IEC 60529/DIN 40050)
terminal area IP00
Vibration
8 g (57-500 Hz) ± 0.61 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Shock
20 g (11 ms)
to IEC 60068-2-27, test Ea
Corrosion
48 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity
96 hours at 95 % RH
to IEC 60068-2-78, test Cab
Mass
approx. 5 g
Approvals
Authority
Standard
Rated voltage
Current ratings
VDE
IEC/EN 60934
AC 240 V
DC 50 V
DC 28 V
0.63 A…10 A
0.63 A…2.25 A
2.5 A…10 A
UL
UL 1077
AC 250 V
DC 50 V
0.63 A…10 A
0.63 A…10 A
CSA
C22.2 No 235
AC 250 V
DC 50 V
0.63 A…10 A
0.63 A…10 A
www.e-t-a.de
2 - 47
Thermal Overcurrent Circuit Breaker 1410-L1/L4
Typical time/current characteristics at +23 °C/+73.4 °F
Dimensions
12.8
.504
8.6
.339
1410-L110-L1F1-S01
1.8
.071
12.5
.492
10000
0.8
1.8
.071
.031
25
.984
mounting holes
Trip time in seconds
5
.197
15
.591
17
.669
20.1
.791
1000
100
10
1
2
6±0,2
.236±.008
16.3±0,2
.642±.008
0.1
1410-L410-P3F1-E04
0.01
S ø4
2
4
6 8 10
20
40
Installation drawings
8.8
.346
15
.591
12.4
.488
5.1
.201
8.6
.339
1
… times rated current
12.8
.504
15.6
.614
17.5
.689
2.5
.098
25
.984
4.6
.181
operating area
blade terminals
DIN 46244-A4.8-0.5
Internal connection diagram
1
.039
1.8
.071
13.5
.531
mounting area
2
1
This is a metric design and millimeter dimensions take precedence (mm )
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
2 - 48
www.e-t-a.de
2015/16
Download